Search Results

Search found 9044 results on 362 pages for 'bad sector'.

Page 269/362 | < Previous Page | 265 266 267 268 269 270 271 272 273 274 275 276  | Next Page >

  • How to cache authentication in Linux using PAM/Kerberos authentication (for CVS)?

    - by Calonthar
    We have several Linux servers that authenticate Linux user passwords on our Windows Active Directory Server using PAM and Kerberos 5. The Linux distro we use is CentOS 6. On one system, we have several Version Control Systems like CVS and Subversion, both of which authenticate users throug PAM, such that users can use their normal Unix resp. Windows AD accounts. Since we started using Kerberos for password authentication, we experienced that CVS on a client machine is often much slower in establishing a connection. CVS authenticates the user on every request (eg. cvs diff, log, update...). Is is possible to cache the credentials that kerberos uses, sucht that is does not need to ask the Windows AD server every time a user executes a cvs action? Our PAM config /etc/pam.d/system-auth looks like the following: auth required pam_env.so auth sufficient pam_unix.so nullok try_first_pass auth requisite pam_succeed_if.so uid >= 500 quiet auth sufficient pam_krb5.so use_first_pass auth required pam_deny.so account required pam_unix.so broken_shadow account sufficient pam_succeed_if.so uid < 500 quiet account [default=bad success=ok user_unknown=ignore] pam_krb5.so account required pam_permit.so password requisite pam_cracklib.so try_first_pass retry=3 password sufficient pam_unix.so md5 shadow nullok try_first_pass use_authtok password sufficient pam_krb5.so use_authtok password required pam_deny.so session optional pam_keyinit.so revoke session required pam_limits.so session [success=1 default=ignore] pam_succeed_if.so service in crond quiet use_uid session required pam_unix.so session optional pam_krb5.so

    Read the article

  • Converting software RAID1 to RAID10 for /boot

    - by luckytaxi
    Array info: /dev/md0 - /dev/sda1 and /dev/sdb1 /dev/md2 - /dev/sda2 and /dev/sdb2 Partition info: /boot - /dev/md0 / - /dev/md1 I have two drives that are setup as RAID1 using software RAID on Redhat. I added two additional drives (same size) and I would like to conver the RAID1 to a RAID10. The problem I'm having is adding the last drive to the array. I've gotten as far as creating a RAID10 with two missing devices but as soon as I add the last drive, all hell breaks loose. It seems /dev/sda1 is the culprit. What I'm not too sure about is how to create the RAID10. I've tried the following mdadm --create /dev/md2 --level=raid10 --raid-device=4 /dev/sdc1 missing /dev/sdd1 missing I then proceeded to fail /dev/sdb1 from /dev/md0 and added that partition to /dev/md2. I proceeded to install the MBR on EACH partition since boot resides on /dev/sdx1 on each drive. As a test, all is well, I'm able to boot back into the system once I do a quick reboot. Now, when I go add the last drive /dev/sda1, it breaks. I attempted to install grub on /dev/sda1 and I get the following ... grub> root (hd0,0) /dev/sda root (hd0,0) /dev/sda Filesystem type is ext2fs, partition type 0xfd grub> setup (hd0) setup (hd0) Checking if "/boot/grub/stage1" exists... no Checking if "/grub/stage1" exists... no Error 2: Bad file or directory type At this point, the array is hosed I believe. I rebooted the server and it refuses to boot.

    Read the article

  • Extremely high mysqld CPU usage with no active queries

    - by RadarNyan
    I have a VPS running Ubuntu 12.04 LTS with LEMP stack, followed the guide from Linode Library (since I'm using a Linode) to setup, and everything worked fine until now. I don't know what's wrong, but my CPU usage just goes up since a week ago. Today things getting really bad - I got 74% CPU usage so I went check and found that mysqld taking too much CPU usage (somewhere around 30% ~ 80%) So I did some Google Search, tried disable InnoDB, restart mysql, reset ntp / system clock (Isn't this bug supposed to happen more than a year ago?!) and reboot my VPS, nothing helped. Even with mysql processlist empty, I still get mysqld CPU usage very high. I don't know what I missed and have totally no idea, any advice would be appreciated. Thanks in advance. Update: I got these from running "strace mysqld" write(2, "InnoDB: Unable to lock ./ibdata1"..., 44) = 44 write(2, "InnoDB: Check that you do not al"..., 115) = 115 select(0, NULL, NULL, NULL, {1, 0}^[[A^[[A) = 0 (Timeout) fcntl64(3, F_SETLK64, {type=F_WRLCK, whence=SEEK_SET, start=0, len=0}, 0xbfa496f8) = -1 EAGAIN (Resource temporarily unavailable) hum... I did tried to disable InnoDB and it didn't fix this problem. Any idea? Update2: # ps -e | grep mysqld 13099 ? 00:00:20 mysqld then use "strace -p 13099", the following lines appears repeatedly: fcntl64(12, F_GETFL) = 0x2 (flags O_RDWR) fcntl64(12, F_SETFL, O_RDWR|O_NONBLOCK) = 0 accept(12, {sa_family=AF_FILE, NULL}, [2]) = 14 fcntl64(12, F_SETFL, O_RDWR) = 0 getsockname(14, {sa_family=AF_FILE, path="/var/run/mysqld/mysqld.sock"}, [30]) = 0 fcntl64(14, F_SETFL, O_RDONLY) = 0 fcntl64(14, F_GETFL) = 0x2 (flags O_RDWR) setsockopt(14, SOL_SOCKET, SO_RCVTIMEO, "\36\0\0\0\0\0\0\0", 8) = 0 setsockopt(14, SOL_SOCKET, SO_SNDTIMEO, "<\0\0\0\0\0\0\0", 8) = 0 fcntl64(14, F_SETFL, O_RDWR|O_NONBLOCK) = 0 setsockopt(14, SOL_IP, IP_TOS, [8], 4) = -1 EOPNOTSUPP (Operation not supported) futex(0xb786a584, FUTEX_WAKE_OP_PRIVATE, 1, 1, 0xb786a580, {FUTEX_OP_SET, 0, FUTEX_OP_CMP_GT, 1}) = 1 futex(0xb7869998, FUTEX_WAKE_PRIVATE, 1) = 1 poll([{fd=10, events=POLLIN}, {fd=12, events=POLLIN}], 2, -1) = 1 ([{fd=12, revents=POLLIN}]) er... now I totally don't get it x_x help

    Read the article

  • MicroSD card getting corrupted for no good reason

    - by ChaosR
    I recently bought an MicroSD card online. It's a Sandisk 16GB class 2. However, it has a nasty problem. Every time I fill it with my data, the fat tables get corrupted. I've tried reformatting it, blanking it, doesn't seem to solve the problem. I have tried windows and linux (ubuntu), both have the problem. I've used my usb microsd readers, and even tried putting it in my phone and putting data on it from there. All have this problem. Now the really odd thing is, besides the corrupted file tables, no programs can find anything wrong with the hardware. I've tried both chkdisk and "badblocks -w", neither give any type of error. Now I don't know if the actual data gets corrupted, or if its just filesystem tables. What happens is that one or more folders start showing a load of chinese-charred (random UTF8 symbols I suppose) folders and files, and it is impossible to do anything with those. All the other data (outside of the corrupted folders) seems fine. I've tried to test it, and the problem doesn't seem to show up until I fill the disk upto about 3~4GB. After that I can still access the data. But as soon as I eject/safely remove/unmount it, the bad things happen somehow. Next time I plug it in, the folders I most recently wrote to (but sometimes also the folders I wrote the time before last time to) are all gibberish. Does anybody have any clue what might be going on here? EDIT: It seems I can't even put ext3 or ext4 on it, they both complain about a corrupted journal. Gheh, guess something is really broken here.

    Read the article

  • Home Sharing and Remote on iTunes causing firewall nags

    - by BoltClock
    It seems that enabling Home Sharing and/or hooking up my iPhone's Remote to iTunes causes Mac OS X Snow Leopard's firewall to freak out and keep nagging every time I launch iTunes to ask if I'd like it to accept incoming connections. If I turn off Home Sharing and forget all Remotes, the nag dialog no longer comes up. I could also disable the firewall, but I think that's a silly thing to do. iTunes is already in the firewall whitelist, so the only thing I know that could cause Mac OS X to nag is a bad application bundle code signature. I checked with this Terminal command: $ codesign -vvv /Applications/iTunes.app/ And sure enough, this is what it outputs: /Applications/iTunes.app/: a sealed resource is missing or invalid /Applications/iTunes.app/Contents/Resources/English.lproj/AutofillSettings.nib/objects.xib: resource added /Applications/iTunes.app/Contents/Resources/English.lproj/iTunesDJSettings.nib/objects.xib: resource added /Applications/iTunes.app/Contents/Resources/English.lproj/MobilePhonePrefs.nib/objects.xib: resource added /Applications/iTunes.app/Contents/Resources/English.lproj/MobilePhoneSetup.nib/objects.xib: resource added /Applications/iTunes.app/Contents/Resources/English.lproj/UniversalAccess.nib/objects.xib: resource added I've tried reinstalling iTunes as suggested by this answer, but Mac OS X still nags about incoming connections and the exact same output is generated when I run the above command again. On my PC, Windows Firewall has never nagged whenever I turn on Home Sharing and hook up Remote on my iPhone. Both computers use iTunes 9.2.1. My Mac runs Mac OS X 10.6.4. Is there anything special I need to do that I might have missed? Or how do I resolve the issue? EDIT: I've updated to iTunes 10, but the nags on my Mac are still there and only go away if I turn off Home Sharing and Remote. EDIT 2: I've updated to Remote 2.0 on my iPhone, but the firewall nags are persisting. Has anyone else had this firewall issue at all?

    Read the article

  • What steps to take when CPAN installation fails?

    - by pythonic metaphor
    I have used CPAN to install perl modules on quite a few occasions, but I've been lucky enough to just have it work. Unfortunately, I was trying to install Thread::Pool today and one of the required dependencies, Thread::Converyor::Monitored failed the test: Test Summary Report ------------------- t/Conveyor-Monitored02.t (Wstat: 65280 Tests: 89 Failed: 0) Non-zero exit status: 255 Parse errors: Tests out of sequence. Found (2) but expected (4) Tests out of sequence. Found (4) but expected (5) Tests out of sequence. Found (5) but expected (6) Tests out of sequence. Found (3) but expected (7) Tests out of sequence. Found (6) but expected (8) Displayed the first 5 of 86 TAP syntax errors. Re-run prove with the -p option to see them all. Files=3, Tests=258, 6 wallclock secs ( 0.07 usr 0.03 sys + 4.04 cusr 1.25 csys = 5.39 CPU) Result: FAIL Failed 1/3 test programs. 0/258 subtests failed. make: *** [test_dynamic] Error 255 ELIZABETH/Thread-Conveyor-Monitored-0.12.tar.gz /usr/bin/make test -- NOT OK //hint// to see the cpan-testers results for installing this module, try: reports ELIZABETH/Thread-Conveyor-Monitored-0.12.tar.gz Running make install make test had returned bad status, won't install without force Failed during this command: ELIZABETH/Thread-Conveyor-Monitored-0.12.tar.gz: make_test NO What steps do you take to start seeing why an installation failed? I'm not even sure how to begin tracking down what's wrong.

    Read the article

  • Windows 7 restarts while being idle

    - by Ondrej Slinták
    My Windows 7 almost always restarts when I keep it idle for ~20-30mins. It happened randomly before, but lately, if I leave the computer I can be sure it's gonna restart after those 30mins. It never happens when I play games or work tho, just when it's idle. It's a fresh install of Windows 7 64bit. I had also problems while installing it, it always crashed while finalizing the install and I had to reinstall again. Eventually it installed on 3rd or 4th try after I deleted all of my partitions and added them again. I thought it might have been a hardware problem, but temperatures seem to be okay and I have no idea how to track what might have been causing it. Any ideas? I'm running Windows 7 64bit on: Gigabyte EX58-UD4P Intel(R) Core(TM) i7 CPU 920 @ 2.67GHz NVIDIA GeForce GTX 260 6GB of DDR3 1066Mhz RAM WDC WD1001FALS-00J7B0 1TB SATA II I have a very bad feeling it might be something with HDD and its compatibility with Windows 7 as I haven't had those problems for 1 year while I had Vista. Edit: I checked Event Viewer critical errors from this night. PC restarted first time at 11:12pm, then at 3:06am and since then every ~20min until I came back to it. Error message is: The system has rebooted without cleanly shutting down first. This error could be caused if the system stopped responding, crashed, or lost power unexpectedly. Source: Kernel-Power

    Read the article

  • Can I still restore partition table?

    - by Johannes Lund
    Once I was going to resize partitions on my Mac HD from Bootcamp. I changed my mind and was going to quit, but apparently I hit a button, which made every single mac partion dissapear, and windows 7 refused to restart and be reinstalled. The 1 TB large HD consists of 3 partions, I believe. Since I can't see their actual size (except bootcamp), this is how I recall it. Macintosh HD about 500GB (Somewhere around 700GB according to disk utillity, but 500 according to Finder, and 500GB was all I could access.) Lion Recovery disk Bootcamp 293.36 GB To fix this I connected my mac via target disk mode to a pc and ran TestDisk. However this is the results: Since I Don't have 10 reputation I cant post the image showing the testdisk results, so I post a link instead hoping it is ok. The two mac partitions' sizes are completely wrong, and BOOTCAMP isn't showing. I tested using disk utilities from the snow leopard dvd. There there is one 293.36 GB Mac OS Extended partition. Before I had the firewire cable for target disk mode I tried reinstalling windows. Without success I tried again formating BOOTCAMP. Was that a bad thing to do? Could it have overwritten data from Macintosh HD? Unfortunately I have no backup. I could bring it to some kind of computer repair firm though.

    Read the article

  • How to create Windows Vista/Windows 7 Startup disk or Rescue disk or system restore points on a CD?

    - by goldenmean
    Hello, I have two laptops, one having Windows-Vista home premium and other one having Windows-7 professional. Both versions of OS are OEM installs(pre-installed when I bought the laptop) and I do not have the Windows Installation disks for them. usually the installation disks provide a repair option in case one needs to repair/rescue a improper windows installation. But since I dont have the installation disks, I want to create rescue disks/startup disks for these. My questions are : 1] How to create a system rescue disk/startup disk on a CD from these two versions of Windows? 2] Doesn't the system restore points which Vista/Windows-7 create, cannot be created on a CD disk instead of hard-disk? 3] If I have a manual backup of my windows registry, in which I have exported all the registry to a file and I have that file on a CD, how to restore that registry back to the windows installation which might not be booting up properly due to bad registry problem. EDIT: 4]Is there any way to use these system restore points directly during bootup of the laptop, if windows does cannot boot properly due to problem. First laptop is HP Pavillion dv6646 and second one is Sony VAIO VCPEE series. thank you. -AD

    Read the article

  • Linux drivers for laser printer Konica Minolta Magicolor 4750DN

    - by user51166
    I would like to install the konica minolta magicolor 4750DN in Linux (debian 64 bits, I know it's not really supported but that's not the issue right now) but all the manual says is "put the CD rom in and copy the drivers and PPD file". However I did not get the CD ! On their "fantastic" internet site (...) there are only available drivers for Windows and Mac OSX. I tried to extract the ppd file from the .dmg file for MacOSX 10.7 but, if the PPD file works, a compiled file (only mac compiled, MACH 4 architectures says the "file" command) does not (obviously "cannot execute binary file", since I'm trying to run a Mac file on Linux). Is there anybody who has the same printer that could lend me the Linux drivers on the CD ROM ? Couldn't find them anywhere on the internet. Any way to execute a Mach (or BSD) binary file on Linux (I don't think is possible, although some "emulators" may exist). Thank you very much. I buyed this printer even because it was advertised as "Linux compatible", only to get this bad surprise. I would be grateful if you could help me solve this problem.

    Read the article

  • DNS failover in a two datacenter scenario

    - by wanson
    I'm trying to implement a low-cost solution for website high availability. I'm looking for the downsides of the following scenario: I have two servers with the same configuration, content, mysql replication (dual-master). They are in different datacenters - let's call them serverA and serverB. Users use serverA - serverB is more like a backup. Now, I want to use DNS failover, to switch users from serverA to serverB when serverA goes down. My idea is that I setup DNS servers (bind/powerdns) on serverA and serverB - let's call them ns1.website.com and ns2.website.com (assuming I own website.com). Then I configure my domain to use them as its nameservers. Both DNS servers will return serverA IP as my website's IP. If serverA goes down I can (either manually or automatically from serverB) change configuration of serverB's DNS, to return IP of serverB as website's IP. Of course the TTL will be low, as it's supposed to be in DNS failovers. I know that it may take some time to switch to serverB (DNS ttl, time to detect serverA failure, serverB DNS reconfiguration etc), and that some small part of users won't use serverB anyway. And I'm OK with that. But what are other downsides of such an approach? An alternative scenario is that ns1.website.com will return serverA IP as website's IP, and ns2.website.com will return serverB IP as website's IP. But AFAIK clients not always use primary nameserver and sometimes would use secondary one. So some small part of users would use serverB instead of serverA which is not quite what I'd like. Can you confirm that DNS clients behave like that and can you tell what percentage of clients would possibly use serverB instead of serverA (statistically)? This one also has the downside that when serverA goes back up, it will be automatically used as website's primary server, which is also a bad situation (cold cache, mysql replication could fail in the meantime etc). So I'm adding it only as a theoretical alternative. I was thinking about using some professional DNS failover companies but they charge for the number of DNS requests and the fees are very high (why?)

    Read the article

  • Which HDD brand do you ..trust

    - by Shiki
    Okay it says its 'subjective' but I believe it's not. Basically I want to ask the community about your preference. Not really 'preference' but actual experience. Like if you never had a problem with Western Digital, then write that in an answer, or if there is one with WD, just vote it up. And so on. (Heard so many stories, experiences. I only had Samsung, Maxtor, WD, Seagate HDDs. Samsung died with bad blocks, had anomalies. Maxtor died so fast I couldn't even try it really and it's really hot, loud. Seagate is just as loud as a jet plane, and moderately hot. My WD (green) is quiet, really cool and somewhat fast. That's all I have about experiences. So I would say Western Digital in an answer (OR Hitachi. Never had one yet, but every expert I know says I should get one since they even had problems with WD but Hitachi seems to be ok. (My laptop comes with Hitachi hdd but I don't think its really relevant.)) Basically I mean desktop 7200RPM HDDs here. Well.. notebook HDDs are ok also, but no raptor/scsi/server ones. Hope you get what I meant and it won't get closed.

    Read the article

  • Problem routing between directly connected Subnets w/ ASA-5510

    - by Zephyr Pellerin
    This is an issue I've been struggling with for quite some time, with a seemingly simple answer (Aren't all IT problems?). And that is the problem of passing traffic between two directly connected subnets with an ASA While I'm aware that best practice is to have Internet - Firewall - Router, in many cases this isn't possible. For example, In have an ASA with two interfaces, named OutsideNetwork (10.19.200.3/24) and InternalNetwork (10.19.4.254/24). You'd expect Outside to be able to get to, say, 10.19.4.1, or at LEAST 10.19.4.254, but pinging the interface gives only bad news. Result of the command: "ping OutsideNetwork 10.19.4.254" Type escape sequence to abort. Sending 5, 100-byte ICMP Echos to 10.19.4.254, timeout is 2 seconds: ????? Success rate is 0 percent (0/5) Naturally, you'd assume that you could add a static route, to no avail. [ERROR] route Outsidenetwork 10.19.4.0 255.255.255.0 10.19.4.254 1 Cannot add route, connected route exists At this point, you might gander if its a NAT or Access list problem. access-list Outsidenetwork_access_in extended permit ip any any access-list Internalnetwork_access_in extended permit ip any any There is no dynamic nat (or static nat for that matter), and Unnatted traffic is permitted. When I try pinging the above address (10.19.4.254 from Outsidenetwork), I get this error message from level 0 logging (debugging). Routing failed to locate next hop for icmp from NP Identity Ifc:10.19.200.3/0 to Outsidenetwork:10.19.4.1/0 This led me to set same-security traffic permit, and assigned the same, lesser and greater security numbers between the two interfaces. Am I overlooking something obvious? Is there a command to set static routes that are classified higher than connected routes?

    Read the article

  • How to set up RAID-0 first time on new PC?

    - by jasondavis
    I have built basic PC's in the past but have never used a RAID array at all. SO now I am buying parts to build my new PC, it will be an intel i7 processor. My motherboard will have RAID support which I will use instead of an aftermarket raid controller for now. Also I plan to use 2 SSD drives in RAID-0 for my windows 7 OS. (Please note that I am aware of the issues with doing this, including lack of TRIM support when using RAID with SSD drives. I am OK with it not working as I can just re[place the drives in a year or so or wheneer they become more sluggish). SO here is my question part. If I assemble the motherboard, PSU, processor, RAM, vidm card, etc and then go to turn the PC on, it will have the 2 SSD drives hooked up. so I assume I will then soon the BIOS screen before I install windows? How to I go about making the 2 drives work in RAID-0 at this point? I do the raid part before installing my OS right? Please help with the steps involved from assembling the parts of the PC and then turning it on, to the part of getting the RAID-0 set up between the 2 drives and then installing my windows 7 OS from a Optical drive? Please help, all advice, instructions, tips appreciated as long as on topic. I do not need to be told that this is a bad idea as far as if 1 drive fails I losse it all, I plan on having a disk IMAGE to be able to restore my OS and software to a new set of drives at anytime needed in the event of drive failure. Same goes for lack of TRIM support. Thanks for reading and help =)

    Read the article

  • Ext3 fs: Block bitmap for group 1 not in group (block 0). is fs dead?

    - by ip
    My company has a server with one big partition with Mysql database and php files. Now this partition seems to be corrupted, as reported from kernel messages when I tried to mount it manually: [329862.817837] EXT3-fs error (device loop1): ext3_check_descriptors: Block bitmap for group 1 not in group (block 0)! [329862.817846] EXT3-fs: group descriptors corrupted! I've tried to recovery it running tools from a PLD livecd. These are the tools I have tested: - e2retrieve - testdisk - photorec - dd_rescue/dd_rhelp - ddrescue - fsck.ext2 - e2salvage without any success. dumpe2fs 1.41.3 (12-Oct-2008) Filesystem volume name: /dev/sda3 Last mounted on: <not available> Filesystem UUID: dd51610b-6de0-4392-a6f3-67160dbc0343 Filesystem magic number: 0xEF53 Filesystem revision #: 1 (dynamic) Filesystem features: has_journal filetype sparse_super Default mount options: (none) Filesystem state: not clean with errors Errors behavior: Continue Filesystem OS type: Linux Inode count: 9502720 Block count: 18987570 Reserved block count: 949378 Free blocks: 11555345 Free inodes: 11858398 First block: 0 Block size: 4096 Fragment size: 4096 Blocks per group: 32768 Fragments per group: 32768 Inodes per group: 16384 Inode blocks per group: 512 Last mount time: Wed Mar 24 09:31:03 2010 Last write time: Mon Apr 12 11:46:32 2010 Mount count: 10 Maximum mount count: 30 Last checked: Thu Jan 1 01:00:00 1970 Check interval: 0 (<none>) Reserved blocks uid: 0 (user root) Reserved blocks gid: 0 (group root) First inode: 11 Inode size: 128 Journal inode: 8 Journal backup: inode blocks dumpe2fs: A block group is missing an inode table while reading journal inode e2fsck 1.41.3 (12-Oct-2008) fsck.ext3: Group descriptors look bad... trying backup blocks... fsck.ext3: A block group is missing an inode table while checking ext3 journal for /dev/sda3 I tried also backup superblocks, same error result. There's any other tools I have to test before considering these disk definitely unrecoverable? Many thanks, ip

    Read the article

  • Apache reports a 200 status for non-existent WordPress URLs

    - by Jonah Bishop
    The WordPress .htaccess generally has the following rewrite rules: # BEGIN WordPress <IfModule mod_rewrite.c> RewriteEngine On RewriteBase / RewriteCond %{REQUEST_FILENAME} !-f RewriteCond %{REQUEST_FILENAME} !-d RewriteRule . /index.php [L] </IfModule> When I access a non-existent URL at my website, this rewrite rule gets hit, redirects to index.php, and serves up my custom 404.php template file. The status code that gets sent back to the client is the correct 404, as shown in this HTTP Live Headers output example: http://www.borngeek.com/nothere/ GET /nothere/ HTTP/1.1 Host: www.borngeek.com {...} HTTP/1.1 404 Not Found However, Apache reports the entire exchange with a 200 status code in my server log, as shown here in a log snippet (trimmed for simplicity): {...} "GET /nothere/ HTTP/1.1" 200 2155 "-" {...} This makes some sense to me, seeing as the original request was redirected to page that exists (index.php). Is there a way to force Apache to report the exchange as a 404? My problem is that bogus requests coming from Bad Guys show up as "successful requests" in the various server statistics software I use (AWStats, Analog, etc). I'd love to have them show up on the Apache side as 404s so that they get filtered out from the stat reports that get generated. I tried adding the following line to my .htaccess, but it had no effect (I'm guessing for the same reason as the previous redirect rules): ErrorDocument 404 /index.php?error=404 Does anyone have a clever way to fix this annoyance? Additional Info: OS is Debian 6.0.4, and Apache version looks to be 2.2.22-3 (hosted on DreamHost) The 404 being sent back to the client is being set by WordPress (i.e. I'm not manually calling header() anywhere)

    Read the article

  • All commands stopped working in centos 6.5

    - by Michael
    I have made a big mistake while removing some duplicate packages as it appears to be broken. yum 1036 rpm -e --nodeps glibc-2.12-1.132.el6_5.2.x86_64 1037 rpm -e --nodeps nscd-2.12-1.132.el6_5.2.x86_64 1038 rpm -e --nodeps glibc-common-2.12-1.132.el6_5.2.x86_64 1040 rpm -e --nodeps glibc-common-2.12-1.132.el6.x86_64 glibc-devel-2.12-1.132.el6.x86_64 glibc-headers-2.12-1.132.el6.x86_64 1041 rpm -e glibc.x86_64 1042 rpm -e --nodeps glibc.x86_64 The issue happened after doing 1042 step. None of commands work(including yum, rpm, ls, cp etc) and getting error /lib64/ld-linux-x86-64.so.2: bad ELF interpreter: No such file or directory I thought that installing glibc after removing all the current ones would help to resolve the duplicate package error :( Now I realised that it is used as the C library in the GNU system and most systems with the Linux kernel. It defines the "system calls" and other basic facilities such as open, malloc, printf, exit, etc. Is there any possible solutions other than reinstall? I have lost ssh access. Maybe anything can be done using rescue cd? Thanks

    Read the article

  • SQL Server replication and load balance

    - by Ahmed Galal
    I'm running a web service that serves a mobile app on IIS 8 and SQL Server 2014, my service has a massive load and i'm trying to improve performance, most of the load is happening on SQL. i don't think i have a bottleneck, my processor and ram is up to the max and i think my code is not that bad, am already using memcached and other stuff to avoid hitting SQL too much. i know i can always upgrade the server hardware but i already have a spare server that i would like to use, so i was thinking to split the SQL load on the 2 servers. What i was thinking of is to setup replication on the other server and do some load balancing, but am not sure how to do the load balance. I know i can adjust my code to hit the other server for some queries but i was hoping to find a solution that avoid changing my code. So my question is, What are the ways of doing load balancing between 2 SQL servers ? I would appreciate suggestions or best practices or some directions. Thanks.

    Read the article

  • Linux VLAN Bridge

    - by raspi
    I have home network with VLANs, one for LAN, one for WLAN and one for internet. I'd like to use bridging so that instead of configuring these same VLANs to every machine, they had own VLAN ID and bridges were LAN, WLAN and internet. I've tried it but for some reason keep-alive/ttl seems to get broken because SSH sessions etc suddenly disconnects. We have this same setup working in workplace for 4+ years with 100+ customers but it's custom firewall/router hardware so accessing it is impossible. I know that it runs Linux. So what is Debian/Ubuntu default network settings doing wrong or is it just NIC driver/hw problem? I've tried to mess araund with ttl etc settings without any luck. The bad stuff is happening in the bridge because current VLAN-only setup works fine. interfaces: auto lo iface lo inet loopback # The primary network interface allow-hotplug eth0 allow-hotplug eth1 iface eth0 inet static iface eth1 inet static auto vlan111 auto vlan222 auto vlan333 auto vlan444 auto br0 auto br1 auto br2 # LAN iface vlan111 inet static vlan_raw_device eth0 # WLAN iface vlan222 inet static vlan_raw_device eth0 # ADSL Modem iface vlan333 inet static vlan_raw_device eth1 # Internet iface vlan444 inet static vlan_raw_device eth0 # LAN bridge iface br0 inet static address 192.168.0.1 netmask 255.255.255.0 bridge_ports eth0.111 bridge_stp on # Internet bridge iface br1 inet static address x.x.x.x netmask x.x.x.x gateway x.x.x.x bridge_ports eth1.333 eth0.444 bridge_stp on post-up iptables -t nat -A POSTROUTING -o br1 -j MASQUERADE pre-down iptables -t nat -D POSTROUTING -o br1 -j MASQUERADE # WLAN bridge iface br2 inet static address 192.168.1.1 netmask 255.255.255.0 bridge_ports eth0.222 bridge_stp on Sysctl: net.ipv4.conf.default.forwarding=1

    Read the article

  • Need Help getting perl module DBD::mysql installed for bugzilla on RedHat.

    - by Alos Diallo
    Hi everyone I am having some issues getting Bugzilla setup, I have the software on the server and am trying to get the pre-rec's setup. I am using RedHat 4.1.2-42. I have all of the required perl modules save one:DBD::mysql When I try: sudo perl install-module.pl DBD::mysql I get the following response(this is only an excerpt): rm -f blib/arch/auto/DBD/mysql/mysql.so LD_RUN_PATH="/usr/lib64/mysql:/usr/lib64:/lib64" /usr/bin/perl myld gcc -shared -O2 -g -pipe -Wall -Wp,-D_FORTIFY_SOURCE=2 -fexceptions -fstack-protector --param=ssp-buffer-size=4 -m64 -mtune=generic dbdimp.o mysql.o -o blib/arch/auto/DBD/mysql/mysql.so \ -L/usr/lib64/mysql -lmysqlclient -lz -lcrypt -lnsl -lm -L/usr/lib64 -lssl -lcrypto \ /usr/bin/ld: skipping incompatible /usr/lib/libssl.so when searching for -lssl /usr/bin/ld: skipping incompatible /usr/lib/libssl.a when searching for -lssl /usr/bin/ld: cannot find -lssl collect2: ld returned 1 exit status make: * [blib/arch/auto/DBD/mysql/mysql.so] Error 1 /usr/bin/make -- NOT OK Running make test Can't test without successful make Running make install make had returned bad status, install seems impossible I then tried the following: CFLAGS="-I/usr/lib64/mysql:/usr/lib64:/lib64" perl install-module.pl DBD::mysql I get the same result. I have also tried to install it using CPAN but also get the same result. Right now I have DBD-mysql v3.0007 but need (v4.00) Also when I try to install open ssl it says I have the latest version. Does anyone know what I have to do to get this to work? Any help would be greatly appreciated. Thank you

    Read the article

  • Radeon 6950 - Garbling of text and graphics in certain Windows only

    - by Greg
    This morning I noticed the text in Gmail (in Firefox 4) looked a little funny (kind of thin, maybe some color fringing). I went to work and thought it might be some ClearType issue or something with the way Direct way that FF4 draws to the screen. When I came back from work (I left the computer on), the problem was much worse - way beyond ClearType nit-picking. The text was barely readable. I opened Chrome and there was no such problem. It seems like only Windows that use hardware acceleration are garbled, and ones that use GDI are not. But, I fired up Dragon Age and didn't notice any problems (I only really looked at the main menu though). Here is a link to a screen shot that illustrates the problem. Notice how the Windows Live Mesh window is completely unreadable, the text in Firefox 4 (left) is pretty bad, while Chrome, the Windows Control Panel, and the task bar are perfectly fine. The fact that the problem shows up in screen shots and that it only happens in certain Windows makes me confident that the problem cannot be with the monitor or DVI cable. I am using the AMD Radeon drivers from 4/27/11. The card I have (MSI Frozr II) came with a slight overclock (810Mhz) out of the box, but it looks like when I'm on the Windows desktop it's not running at full clock (CCC reports 450Mhz). Still, I underclocked it to the stock reference clock (800Mhz) and it made no difference. The idle temperature according to Afterburner is 42-44 Celsius, which seems a tad high but not enough to cause a problem - it's cold to the touch if I open up the machine. What the heck could be causing this? The problem varies in intensity. As we speak I'm in Firefox and things look better than they did earlier - it'll probably get worse again soon. Radeon 6950 (MSI Frozr II), Seasonic X 560, Core i5 2500K at stock clockspeeds, 16GB RAM, Asus P8P67 M Pro

    Read the article

  • Including email, IMs, configs, etc. in documentation or notes

    - by Jason Antman
    The shop I work in is pretty laid-back. We're on a documentation kick, only because historically we've been very bad with it. We do a lot of our brainstorming in face-to-face meetings, and also do a lot of communication via IM in addition to email. While I'm usually pretty good about documentation and keeping copious lab notes, I just finished a build of a host and spent hours searching through IMs, emails, files on my workstation, etc. to pull out anything I missed in my lab notes, which formed a large amount of the basis for the internal documentation. Does anyone have any thoughts on, aside from manually saving things to a project directory, managing various data sources (especially email and IM) and tracking them on project basis? Ideally, I'd like an easy way to put copies of emails, IM logs, etc. into a project-specific directory on my workstation and then just have a cron job that syncs that up with a shared folder. This isn't really a candidate for anything more advanced, as the bulk of the data will be copies of configs, code, etc. Here are the big restrictions: Email is via a centralized Zimbra install, so nothing can happen server-side. My workstation is Linux. Aside from writing Pidgin and Thunderbird plugins that let me tag chats and emails as belonging to a project, and then copy them to the appropriate place... any thoughts? Suggestions? Thanks, Jason

    Read the article

  • Cannot write samba shares

    - by Batsu
    Running samba 3.5 on Red Hat Enterprise 6.1 I'm having issues sharing two folders. Here is the output of testparm: [global] workgroup = DOMAINNAME server string = Samba Server Version %v interfaces = lo, eth1 bind interfaces only = Yes map to guest = Bad User log file = /var/log/samba/log.%m max log size = 50 idmap uid = 16777216-33554431 idmap gid = 16777216-33554431 hosts allow = 10.50.183.48, 10.50.184.41, 10.50.184.199, 10.50.183.160, 127.0.0.1 hosts deny = 0.0.0.0/0 cups options = raw [test] comment = test folder path = /usr/local/samba valid users = claudio write list = claudio force user = claudio read only = No create mask = 0775 directory mask = 0775 [test2] comment = another test path = /home/claudio/tst valid users = claudio write list = claudio force user = claudio read only = No create mask = 0775 From the Windows XP machine I'm connecting from I'm able to read test but not write, while for test2 I can't even access the folder (though I can see it listed). ls -l /usr/local ... drwxrwxrwx. 2 claudio claudio 4096 Dec 3 10:39 samba ... ls -l /user/local/samba total 32 -rwxrwxrwx. 1 claudio claudio 9 Nov 29 16:26 asd.txt -rwxrwxrwx. 1 claudio claudio 728 Dec 3 10:16 out.txt ... ls -l /home/claudio/ ... drwxrwxr-x. 2 claudio claudio 4096 Dec 3 09:57 tst ... ls -l /home/claudio/tst total 4 -rw-rw-r--. 1 claudio claudio 4 Dec 3 09:57 asd.txt Any suggestion?

    Read the article

  • Timeout option not working on efi windows 7/windows8 dual boot machine

    - by Guenter
    I hav a gigbyte GA-Z77m-D3h mobo and installed Windows 8 Pro and Windows 7 Ultimate on two SSDs (in that order) in EFI mode. Now when I start my computer, I get the windows boot menu (text mode) with the two OSses to choose, but I have to manually press RETURN to have the computer boot into the Win OS. Even if I wait an hour, no default action takes place. Using bcdedit (from either of the OSses) I can successfully change the time out value, and it shows up in the bcdedit (no params) output. But it doesn't fire ... Here is my current BCDEdit output (headers are in German, but values should be readable): Windows-Start-Manager --------------------- Bezeichner {bootmgr} device partition=O: path \EFI\Microsoft\Boot\bootmgfw.efi description Windows Boot Manager locale de-DE inherit {globalsettings} integrityservices Enable default {default} resumeobject {5ad2802c-c60a-11e2-acdb-80331c501b11} displayorder {default} {current} {5ad2802a-c60a-11e2-acdb-80331c501b11} {5ad28028-c60a-11e2-acdb-80331c501b11} {5ad28029-c60a-11e2-acdb-80331c501b11} toolsdisplayorder {memdiag} timeout 5 displaybootmenu Yes Windows-Startladeprogramm ------------------------- Bezeichner {default} device partition=W: path \Windows\system32\winload.efi description Windows 7 locale de-DE inherit {bootloadersettings} recoverysequence {5ad2802e-c60a-11e2-acdb-80331c501b11} recoveryenabled Yes osdevice partition=W: systemroot \Windows resumeobject {5ad2802c-c60a-11e2-acdb-80331c501b11} nx OptIn Windows-Startladeprogramm ------------------------- Bezeichner {current} device partition=C: path \Windows\system32\winload.efi description Windows 8 locale de-DE inherit {bootloadersettings} recoverysequence {5ad28033-c60a-11e2-acdb-80331c501b11} integrityservices Enable recoveryenabled Yes isolatedcontext Yes allowedinmemorysettings 0x15000075 osdevice partition=C: systemroot \Windows resumeobject {5ad28031-c60a-11e2-acdb-80331c501b11} nx OptIn bootmenupolicy Standard hypervisorlaunchtype Auto (this output is from Win8; the Win7 looks nearly identical) If maybe the problem comes from a bad EFI Windows boot manager installation, can this be fixed without loosing my windows installations?

    Read the article

  • Authority Information Access local path being ignored

    - by Kevin
    I have a CA set up in Server 2008 R2, and generally it is working, but I can't control the local path/filename it writes its own certificate to for the Authority Information Access publishing. Here's a screen shot of the dialog I'm trying to set this on: From these settings I would expect to get the file: C:\Windows\system32\CertSrv\CertEnroll\DAMNIT.crt But instead I get: C:\Windows\system32\CertSrv\CertEnroll\SERVER.domain.com_My Issuing Authority(1).crt Of course, the actual change shown wouldn't be very useful, but it's illustrative; no matter what path/filename I use, it always lands up in the same place and with the same name. I actually wanted to change the name from <ServerDNSName>_<CaName><CertificateName>.crt to <CaName><CertificateName>.crt, since the latter corresponds to the HTTP URL whereas the former does not. Admittedly, I haven't set up many CAs so perhaps I'm just deluded as to what this dialog is supposed to be setting, but if so this is notoriously bad UI design. (Incidentally, I have a couple other complaints with the same dialog.) What's going on here and is there some way to get the filename pattern I want?

    Read the article

< Previous Page | 265 266 267 268 269 270 271 272 273 274 275 276  | Next Page >