  • A quick look at: sys.dm_os_buffer_descriptors

    - by fatherjack
    SQL Server places data into cache as it reads it from disk so as to speed up future queries. This dmv lets you see how much data is cached at any given time and knowing how this changes over time can help you ensure your servers run smoothly and are adequately resourced to run your systems. This dmv gives the number of cached pages in the buffer pool along with the database id that they relate to: USE [tempdb] GO SELECT COUNT(*) AS cached_pages_count , CASE database_id ...(read more)

    Read the article

  • No upgrade option when booting from USB (12.04)

    - by Ramzi Njeim
    I am trying to upgrade my ubuntu 11.10, i know that it is better to upgrade using a live cd/usb, i booted from the live usb, followed the instructions as usual, but only found three options: Cleen install Install alongside your other operating systems Other The upgrade choice was missing. I even tried installing it after running ubuntu 12.04 from usb, and ended up with the same result. I have a dual boot Ubuntu 11.10 and Windows 7, i think it is only seeing the windows 7 and missing the ubuntu 11.10 partition. Any help ?

    Read the article

  • Questions on first install

    - by Jordan March
    I've just installed Ubuntu 12.10 64bit on dual boot with windows 7. I've been looking for a lot of the things people say to download, like myunity but when I search in the software center, nothing comes up, just stuff like magazines. Do I need to add some ppas for it to see them? What are some that I should add on a new install? And can anyone help me get myunity on here so I can start customising my desktop? Thanks

    Read the article

  • Installing WINE 1.4 Errors on Precise 12.04

    - by user71965
    This message is consistently received when installing WINE1.4, which fails to install properly update-initramfs: Generating /boot/initrd.img-3.2.0-25-generic-pae Fatal: No images have been defined. run-parts: /etc/initramfs/post-update.d//runlilo exited with return code 1 dpkg: error processing initramfs-tools (--configure): subprocess installed post-installation script returned error exit status 1 Errors were encountered while processing: initramfs-tools Any thoughts appreciated.

    Read the article

  • GUI stops responding after a few seconds

    - by Nucklear
    I'm dual-booting Windows 7 and Ubuntu 12.04. When I boot Ubuntu, the interface doesn't respond to my requests. I can launch applications from the unity launcher, but when I try to close them it doesn't respond; even when I try to maximize it does nothing. I tried restarting the GUI, but after a few seconds it happens again. I had the same issue with older versions of Ubuntu and never figured it out.

    Read the article

  • Your own OEM configuration: YaST Firstboot

    <b>openSUSE Lizards:</b> "The YaST firstboot utility is a special kind of configuration workflow that can be run after the basic system is installed. It is started on the first boot of the system and guides a user through a series of steps that allow for easier configuration of their desktops."

    Read the article

  • Getting the Most out of Statistics

    Statistics keep track of our data and will tell SQL Server how to make the best optimization decisions. Knowing how they work can make understanding query and performance problems much easier! Free eBook - Performance Tuning with DMVsThis free eBook provides you with the core techniques and scripts to monitor your query execution, index usage, session and transaction activity, disk IO, and more. Download the free eBook.

    Read the article

  • Downgrading Ubuntu 13.10 [duplicate]

    - by empec
    This question already has an answer here: How to roll back Ubuntu to a previous version? 9 answers I'd like to downgrade from Ubuntu 13.10 back to an older version. i.e. 13.04. Can I just boot ubuntu installer, uninstall Ubuntu 13.10 and install 13.04 without any problems to my home folder?

    Read the article

  • Analyzing I/O performance in Linux

    <b>cmdln.org:</b> "Monitoring and analyzing performance is an important task for any sysadmin. Disk I/O bottlenecks can bring applications to a crawl. What is an IOP? Should I use SATA, SAS, or FC? How many spindles do I need?"

    Read the article

  • Unable to access “430 GB Volume”

    - by user170924
    Error mounting /dev/sda3 at /media/fehr/D42CAFD92CAFB4C0: Command-line `mount -t "ntfs" -o "uhelper=udisks2,nodev,nosuid,uid=1000,gid=1000,dmask=0077,fmask=0177" "/dev/sda3" "/media/fehr/D42CAFD92CAFB4C0"' exited with non-zero exit status 14: The disk contains an unclean file system (0, 0). Metadata kept in Windows cache, refused to mount. Failed to mount '/dev/sda3': Operation not permitted The NTFS partition is in an unsafe state. Please resume and shutdown Windows fully (no hibernation or fast restarting), or mount the volume read-only with the 'ro' mount option.

    Read the article

  • so disappointed at ubuntu 12.04 [closed]

    - by Min
    it's been almost a month I've installed ubuntu I can't afford windows cd anymore it is my fault that I didn't dual boot it but, it doesn't make sense in that I can't use my own graphic card in my own computer because certain company doesn't support the driver card for the OS it is seemingly ridiculous that I can't even run a simple 2d game or not even a flash game with this OS a video of 480 and up doesn't run for closely a month I've tried my best to run everything my computer spec provides, but nothing works. not even sound quality

    Read the article

  • ??????????

    - by Allen Gao
    ???????RAC??????????????????10gR2?11gR1.??????????????CRS???????1.ocssd : ???????????(Node Monitoring)????(Group Management),??CRS????????????????????????,????????????(network heartbeat)?????(disk heartbeat)???,?????????????????????,????????????,??????????????????,?????node kill escalation(???11gR1????????),??????????????????????????(reboot time,???3?)????????:ocssd.bin??????????????????????????,??????????????????????????????,misscount(???30?,??????????????600?),????????????,???????????????????,?????????????2???,??????,??????????????,?????????????????????:ocssd.bin?????????????(Voting File)??????????,?????????????????????????????,disk timeou(???200?),?????????????????????,CRS???[N/2]+1????????,??N??????,??????2.oclsomon:????????ocssd????,????ocssd.bin??????,???????3.oprocd:??????Linux?Unix??,????????????????????????????????,?????????:????????????init.cssd?????????????????????????1.??????2.<crs???>/log/<????>/cssd/ocssd.log3.oprocd.log(/etc/oracle/oprocd/*.log.* ? /var/opt/oracle/oprocd/*.log.*)4.<crs???>/log/<????>/cssd/oclsomon/oclsomon.log5. Oracle OSWatcher ????????????????????1.?ocssd???????????ocssd.log???????,????????????????????????????????,???????,OSW??(traceroute???),???????(cluster interconnect)??????,?????????[ CSSD]2012-03-02 23:56:18.749 [3086] >WARNING: clssnmPollingThread: node <node_name> at 50% heartbeat fatal, eviction in 14.494 seconds[ CSSD]2012-03-02 23:56:25.749 [3086] >WARNING: clssnmPollingThread: node <node_name> at 75% heartbeat fatal, eviction in 7.494 seconds[ CSSD]2012-03-02 23:56:32.749 [3086] >WARNING: clssnmPollingThread: node <node_name>at 90% heartbeat fatal, eviction in 0.494 seconds[CSSD]2012-03-02 23:56:33.243 [3086] >TRACE:   clssnmPollingThread: Eviction started for node <node_name>, flags 0x040d, state 3, wt4c 0[CSSD]2012-03-02 23:56:33.243 [3086] >TRACE:   clssnmDiscHelper: <node_name>, node(4) connection failed, con (1128a5530), probe(0)[CSSD]2012-03-02 23:56:33.243 [3086] >TRACE:   clssnmDiscHelper: node 4 clean up, con (1128a5530), init state 5, cur state 5[CSSD]2012-03-02 23:56:33.243 [3600] >TRACE:   clssnmDoSyncUpdate: Initiating sync 196446491[CSSD]2012-03-02 23:56:33.243 [3600] >TRACE:   clssnmDoSyncUpdate: diskTimeout set to (27000)ms??:???????ocssd.log?????????????????????,?????????????????????ocssd.log???????,??????????????????????????????,OSWatcher??(iostat???),???i/o????????,?????????2010-08-13 18:34:37.423: [    CSSD][150477728]clssnmvDiskOpen: Opening /dev/sdb82010-08-13 18:34:37.423: [    CLSF][150477728]Opened hdl:0xf4336530 for dev:/dev/sdb8:2010-08-13 18:34:37.429: [   SKGFD][150477728]ERROR: -9(Error 27072, OS Error (Linux Error: 5: Input/output errorAdditional information: 4Additional information: 720913Additional information: -1))2010-08-13 18:34:37.429: [    CSSD][150477728](:CSSNM00060: )clssnmvReadBlocks: read failed at offset 17 of /dev/sdb82010-08-13 18:34:38.205: [    CSSD][4110736288](:CSSNM00058: )clssnmvDiskCheck: No I/O completions for 200880 ms for voting file /dev/sdb8)2010-08-13 18:34:38.206: [    CSSD][4110736288](:CSSNM00018: )clssnmvDiskCheck: Aborting, 0 of 1 configured voting disks available, need 12010-08-13 18:34:38.206: [    CSSD][4110736288]###################################2010-08-13 18:34:38.206: [    CSSD][4110736288]clssscExit: CSSD aborting from thread clssnmvDiskPingMonitorThread 2010-08-13 18:34:38.206: [    CSSD][4110736288]###################################2. ?oclsomon???????????oclsomon.log ?????,??????????ocssd????,??ocssd??????(RT)???,?????????????(?cpu)??,?????????????,OSW??(vmstat,top???),?????????3.?oprocd???????????oprocd?????????,?????????oprocd????? Dec 21 16:15:30.369857 | LASTGASP | AlarmHandler:  timeout(2312 msec) exceeds interval(1000 msec)+margin(500 msec).   Rebooting NOW.??oprocd?????????????????????,?????ntp(?????????),??diagwait=13 ????????,??,?????????????,??????CRS,???????????????,??????????????oprocd????,??,?????OSWatcher??(vmstat,top???),??????????????????????????????,????????????????? ???????,??????MOS ???Note 265769.1 :Troubleshooting 10g and 11.1 Clusterware RebootsNote 1050693.1 :Troubleshooting 11.2 Clusterware Node Evictions (Reboots)

    Read the article

  • "shutting down hyper-v virtual machine management service"

    - by icelava
    I have a Windows 2008 R2 server that is a Hyper-V host (Dell PowerEdge T300). Today for the first time I encountered an odd situation; i lost connection with one of the guest machines but logging on physically it seems the guest OS is still running but no longer contactable via the network. I tried to shut down the guest machine (Windows XP) but it would not shut down, getting stuck in a "Not responding" dialog box that cannot be dismissed. I used the Hyper-V management console to reset the machine and it could not get out of resetting state. I tried to save another Windows 2003 guest machine, and it would be progress with its Saving state (0%). The other running Windows 2003 guest was stuck in the logon dialog. My first suspicion is perhaps one of the Windows update patches this week (10 Nov 2011) may something to do with it, which was still pending a system restart. Well, since I could not do anything with Hyper-V i proceeded with the Windows Update restart, and now it is stuck half an hour at "Shutting down hyper-v virtual machine management service" Prior to restarting I did not observe any hard disk errors reported in the system event log; doubt it is a disk-related condition. Shall I force a hard reboot? UPDATE As per answer report, it eventually restarted itself.

    Read the article

  • What does "single-bit ECC errors were detected on the RAID controller" mean?

    - by jsp
    I have a Dell T7600 with a Perc H710P RAID controller and 4 attached 3TB drives. Over the past few months the RAID controller has been intermittently reporting errors on boot: "no boot device found", "adapter at baseport is not responding", disks frequently reported as missing or failed. I have since replaced the RAID controller, the 4 hard drives, and finally the system's motherboard. After replacing the motherboard and rebooting a few times, I got the error Single bit ECC errors were detected on the RAID controller. Please contact technical support to resolve this issue. After rebooting about 20 more times, I haven't seen the ECC error. The system seems otherwise OK, except for the fact that the disk fans will sometimes start blowing at full blast when the the system is sitting completely idle and not stop until I reboot. Are the ECC errors in memory on the RAID controller? Or, does the RAID controller map in system memory, and the ECC errors are really in system memory? Or, are the ECC errors in the 1GB cache that resides in the RAID controller?

    Read the article

  • Oracle VM repository creation seems contradictory to its server pool?

    - by Michael
    I found something contradictory in Oracle VM. Clustered server pool creation in Oracle VM would format my FC LUN as ocfs2 , and start o2cb & ocfs2 services to build cluster environment. After that, when I wanted to create repository on the serverpool, unexpectedly, it told me that the physical disk I chose which is also my FC LUN, already contains a file system. What a contradictory! So what, delete the file system in serverpool? If so, why created it before?! OVM> list physicaldisk Command: list physicaldisk Status: Success Time: 2012-09-10 06:44:42.660 Data: id:0004fb00001800007765e62381895f61 name:OVM_HDS OVM> create serverpool clusterenable=true virtualip=10.84.21.123 physicaldisk=OVM_HDS name=ovmserverpool Serverpool creation took quite a long time since my FC LUN was big. When the creation completed, my FC LUN was created as ocfs2 and o2cb & ocfs2 services were started on my ovm servers successfully. But then repository creation indeed throws me a big surprise ... OVM> create repository serverpool=ovmserverpool physicaldisk=OVM_HDS name=ovmrepo Command: create repository serverpool=ovmserverpool physicaldisk=OVM_HDS name=ovmrepo Status: Failure Time: 2012-09-10 06:23:44.656 Error Msg: com.oracle.ovm.mgr.api.exception.RuleException: OVMRU_002026E Cannot use or delete physical disk: OVM_HDS, it already contains a file system: [Pool filesystem for ovmserverpool] Mon Sep 10 06:23:44 CST 2012 What should I do now? Delete the filesystem using dd command? That would destroy the serverpool, right? I'm really confused. My OVM Manager version is 3.1.1.399 which is the latest. Any tips are appreciated. Thanks.

    Read the article

  • HP P212 hangs on Initializing

    - by user927586
    I'm in trouble... Server: HP Microserver N36L Storage: HP P212/256 with BBWC Drives: 4 WD 2 Tb While expanding the RAID 5 array from 3 to 4 drives, the server rebooted itself. Expansion was at 76%. Now at boot the P212 seems to hang on initializing. After some time screen resets and the server boots, but in the os (Windows Server 2008R2) the P212 has errors (error code 10) and it's not seen by the HP ACU. Whats' going on? It's trying to complete the expansion? It's trying to make all over the expansion? It's simply stuck? What should I do? I NEED the data on the array! PS In the server BIOS, on the hd boot priority, the server still reports the array logical drive... maybe it's a good sign... PPS I'm not at the server physical location, so I cannot tell if the drives in the array are being accessed (that would be the case if the controller it's redoing/completing the expansion process) or not right now. Bye Dario

    Read the article

  • Adaptec 6405 RAID controller turned on red LED

    - by nn4l
    I have a server with an Adaptec 6405 RAID controller and 4 disks in a RAID 5 configuration. Staff in the data center called me because they noticed a red LED was turned on in one of the drive bays. I have then checked the status using 'arcconf getconfig 1' and I got the status message 'Logical devices/Failed/Degraded: 2/0/1'. The status of the logical devices was listed as 'Rebuilding'. However, I did not get any suspicious status of the affected physical device, the S.M.A.R.T. setting was 'no', the S.M.A.R.T. warnings were '0' and also 'arcconf getsmartstatus 1' returned no problems with any of the disk drives. The 'arcconf getlogs 1 events tabular' command gives lots of output (sorry, can't paste the log file here as I only have remote console access, I could post a screenshot though). Here are some sample entries: eventtype FSA_EM_EXPANDED_EVENT grouptype FSA_EXE_SCSI_GROUP subtype FSA_EXE_SCSI_SENSE_DATA subtypecode 12 cdb 28 00 17 c4 74 00 00 02 00 00 00 00 data 70 00 06 00 00 00 00 00 00 00 00 00 02 00 00 00 00 00 00 00 00 00 00 00 00 0 The 'arcconf getlogs 1 device tabular' command reports mediumErrors 1 for two of the disks. Today, I have checked the status of the controller again. Everything is back to normal, the controller status is now 'Logical devices/Failed/Degraded: 2/0/0', the logical devices are also all back to 'Optimal'. I was not able to check the LED status, my guess is that the red LED is off again. Now I have a lot of questions: what is a possible cause for the medium error, why it is not reported by the SMART log too? Should I replace the disk drives? They were purchased just a month ago. The rebuilding process took one or two days, is that normal? The disks are 2 TByte each and the storage system is mostly idling. the timestamp of the logs seem to show the moment of the log retrieval, not the moment of the incident. Please advise, all help is very appreciated.

    Read the article

  • Errors with nginx: proc must be mounted. Why do these happen?

    - by Crashalot
    We see these errors in our nginx log error file. What causes them, and what is the right way to fix them on an ongoing basis (as opposed to running "mount /proc /proc -t proc")? We're on nginx 1.4.1 and Passenger 4.0.5. [ 2013-06-28 08:22:17.7621 2739/7ff58d8f3700 Pool2/SmartSpawner.h:301 ]: Preloader for /home/p/p started on PID 5181, listening on unix:/tmp/passenger.1.0.2735/generation-0/backends/preloader.5181 [ 2013-06-28 12:59:31.1651 2739/7ff59078f700 Pool2/Spawner.h:159 ]: [App 19777 stderr] Error: /proc must be mounted [ 2013-06-28 12:59:31.1651 2739/7ff59078f700 Pool2/Spawner.h:159 ]: [App 19777 stderr] To mount /proc at boot you need an /etc/fstab line like: [ 2013-06-28 12:59:31.1651 2739/7ff59078f700 Pool2/Spawner.h:159 ]: [App 19777 stderr] /proc /proc proc defaults [ 2013-06-28 12:59:31.1651 2739/7ff59078f700 Pool2/Spawner.h:159 ]: [App 19777 stderr] In the meantime, run "mount /proc /proc -t proc" [ 2013-06-28 12:59:31.1652 2739/7ff58d871700 Pool2/Spawner.h:739 ]: [App 19777 stdout] [ 2013-06-28 12:59:34.6642 2739/7ff59078f700 Pool2/Spawner.h:159 ]: [App 19777 stderr] Error: /proc must be mounted [ 2013-06-28 12:59:34.6643 2739/7ff59078f700 Pool2/Spawner.h:159 ]: [App 19777 stderr] To mount /proc at boot you need an /etc/fstab line like: [ 2013-06-28 12:59:34.6643 2739/7ff59078f700 Pool2/Spawner.h:159 ]: [App 19777 stderr] /proc /proc proc defaults [ 2013-06-28 12:59:34.6643 2739/7ff59078f700 Pool2/Spawner.h:159 ]: [App 19777 stderr] In the meantime, run "mount /proc /proc -t proc" [ 2013-06-28 12:59:34.6651 2739/7ff58d871700 Pool2/SmartSpawner.h:301 ]: Preloader for /home/p/p started on PID 19777, listening on unix:/tmp/passenger.1.0.2735/generation-0/backends/preloader.19777

    Read the article

  • "Dictionary problem." Error with VMPlayer

    - by George Mauer
    I'm pretty new to using vmware virtualization (been a virtualbox user) so I'm hoping you guys can help me out. I recently got an external usb disk containing a vm for a client, downloaded vmplayer, set it up with "Open a Virtual Machine", ran it, easy as pie. After working with it a bit this morning, I shut the VM down and now trying to start it back up again I get this: I tried removing the vm from my library, now it happens whenever I try to add it back in. In the meantime, I can still access other virtual machines so it seems like the problem might be with the virtual disk. So two questions: This is obviously not a very helpful error message. Where can I go to get more information? My Application EventLog doesn't contain anything from VMWare. What steps can I take to fix the problem? Edit: A couple more pieces of information. I did not take any snapshots. I don't think VM Player even has that ability. I have a zip file of (what I assume) is the state of the VM when it was sent to me. I cannot unzip it as it is huge and simply requires more HD space than I have available but I did extract the vmx file and examine it. Other than the UUIDs and the fact that mine reads cleanShutdown = "FALSE" they are identical. The log contains the following lines Jun 23 10:11:18.080: vmx| SNAPSHOT: SnapshotConfigInfoRead: Unable to load dict from 'E:....\MachineName.vmsd'. Jun 23 10:11:18.080: vmx| SNAPSHOT: SnapshotConfigInfoRead failed for file 'E:....\MachineName.vmx': Dictionary problem (6) Jun 23 10:11:18.082: vmx| SNAPSHOT: Snapshot_TimeStampTiers failed: Dictionary problem (6)

    Read the article

  • Performance analytics via DBMS "plugins", or other solution

    - by Polynomial
    I'm working on a systems monitoring product that currently focuses on performance at the system level. We're expanding out to monitoring database systems. Right now we can fetch simple performance information from a selection of DBMS, like connection count, disk IO rates, lock wait times, etc. However, we'd really like a way to measure the execution time of every query going into a DBMS, without requiring the client to implement monitoring in their application code. Some potential solutions might be: Some sort of proxy that sits between client and server. SSL might be an issue here, plus it requires us to reverse engineer and implement the network protocol for each DBMS. Plugin for each DBMS system that automatically records performance information when a query comes in. Other problems include "anonymising" the SQL, i.e. taking something like SELECT * FROM products WHERE price > 20 AND name LIKE "%disk%" and producing SELECT * FROM products WHERE price > ? AND name LIKE "%?%", though this shouldn't be too difficult with some clever parsing and regex. We're mainly focusing on: MySQL MSSQL Oracle Redis mongodb memcached Are there any plugin-style mechanisms we can utilise for any of these? Or is there a simpler solution?

    Read the article

  • Random software/shutdown problems Mac mini

    - by Oliver
    Hello I have a Mac mini using OS X 10.5.8. Recently I've been having problems that are becoming increasingly severe. Particular symptoms: Firefox "quits" but the dot on the dock remains. If I try shutting down at this point I can't and have to use the power button. I can't start Firefox either. Significantly higher than normal crash rate for CS4 Illustrator Photoshop and Dreamweaver. If Firefox remains open when sleeping the Mac, on waking up firefox is completely unresponsive and must be restarted. Can cause problem 1. Today I lost all my FTP settings for Dreamweaver CS4 Bluetooth switches on when booting despite being switched off. Network password retention is somewhat erractic. Tried running Apple Hardware Test as described in the manual. Cannot access install disk by pressing D at startup. My pen tablet (Bamboo) lost my preferences. Tried unstalling software and now cannot re-install. I've never had problems of this level outside warranty before so I don't know much about debugging Macs. Solutions attempted: Disable bluetooth (see problem 5) Disable time machine Run appple harware test (see problem 7) Tried using activity monitor but don't know which processes are normal Tried uninstalling more recent software. I don't have any idea what to do. It seems like a hard disk failure but I don't have the know how to continue.

    Read the article

  • Excel techniques for perfmon csv log file analysis

    - by Aszurom
    I have perfmon running against several servers, where I'm outputting to a .csv file data like CPU %time, memory bytes free, hard disk I/O metrics like s/write and writes/s. The ones graphing the SQL servers are also collecting SQL stats. The web servers are collecting .Net relevant stuff. I am aware of PAL, and used it as a template of what data to capture based on server type actually. I just don't think the output it generates is detailed or flexible enough - but it does a pretty remarkable job of parsing logs and making graphs. I'm borderline incompetent with Excel, so I'm hoping to be directed to some knowledge of how to take a perfmon output .csv and mine it in Excel to produce some numbers that are meaningful to me as a sysadmin. I could of course just pick a range of data and assemble a graph out of that and look for spikes and trends, but I'm convinced there is some technique to this that makes it more manageable than looking at a monsterous spreadsheet of numbers and trying to make graphs of it. Plus, it's pretty time consuming and not something I can do as a "take a glance at the servers" sort of routine. I'm graphing CPU, disk use, network b/sec, etc. in Cacti as well, which is nice for seeing big trends. The problem is that it is 5 minute averages, so a server could have a problem but it's intermittent and washes out in a 5 min average. What do you do with perfmon data that I could learn from?

    Read the article

  • How to mount a LOFS in Solaris that doesn’t cross mountpoints

    - by jcea
    I need to access my "root" ZFS dataset to delete a file under "/var". But "/var" is overlayed by another ZFS dataset. Since these are system datasets I can't "umount" them while the machine is running. And I want to avoid to reboot the system in "failsafe" mode, since this is a production machine. Teorically ZFS would refuse to mount "/var" dataset over the underlying "/var", because it is not empty. But it works, possibly because they are system datasets mounted early in the boot process. But having the underlying "/var" not empty is preventing me to create an ABE (Alternate Boot Environment), so patching is risky, and I can't upgrade my system using Live Upgrade. The machine is remote. I have an IP KVM, but I rather prefer to avoid booting this machine in "failsafe" mode, if I can. I know there is a file in "/var/" because I can snapshot the "root" dataset and check it. But snapshots are read-only, so I can't get rid of the file. I tried "mkdir /tmp/zzz; mount -F lofs / /tmp/zzz", but when I go to "/tmp/zzz/var", I see the "/var" dataset, not the underlying "root" dataset. That is, the LOFS is crossing mountpoints. I would usually like it, but not this time!. Any suggestion, beside rebooting the machine in "failsafe" and mess with it thru the IP KVM?

    Read the article