Search Results

Search found 15160 results on 607 pages for 'boot disk'.

Page 326/607 | < Previous Page | 322 323 324 325 326 327 328 329 330 331 332 333  | Next Page >

  • Deploying workstations - best practices?

    - by V. Romanov
    Hi guys I've been researching on the subject of workstation deployment for a while, and found a ton of info and dozens different methods and tools, but no "best practice" method that doesn't lack at least one feature that i consider required for the solution to be perfect. I'm currently interested in windows workstation deployment, but if the tools can be extended to Linux, then it's an added value. I want the deployment tools I use to be able to do the following: hardware independent - I want my image or installation to have a minimum of hardware and driver dependency, so that i can use a single image/package for all workstations easily updatable - I want to be able to update my image as easily as possible without redeploying/rebuilding/reimaging all configurations PXE bootable deployment - I want the tools to be bootable off the network so that I don't need a boot cd/DOK. scriptable for minimum human input - Ideally, the tool should run automatically after being booted and perform a "default" deployment (including partitioning) unless prompted otherwise. i.e - take a pc, hook it up, power on, PXE boot and forget about it until the OS is deployed. I found no single product or environment that does all this. Closest i came to is the windows deployment services/WIM image format. I also checked out numerous imaging and deployment tools including clonezilla, ghost, g4u, wpkg and others, but most of them lack the hardware Independence and updatability features. We currently have a Symantec Ghost server setup that does imaging over the network, but I'm not satisfied with it as it has all the drawbacks i listed above. Do you have suggestions how to optimize the process of workstation deployment? How do you deploy them in your organization? Thanks! Vadim.

    Read the article

  • How do I configure nVidia drivers on a Portable Ubuntu setup?

    - by Nicholas Flynt
    I've been pulling my hair out over this one for a couple of days now, google is no help. I've created a wonderful (until this issue) portable copy of Ubuntu linux that will boot on mostly anything by using a USB enclosure for my laptop's 80GB SATA drive. So far so good, it boots and runs on everything, and on non-nVidia card setups was even detecting the drivers, or letting me install the required drivers for hardware acceleration and compiz. Because you know, the wobble windows are the most awesome thing ever. Anyway, my desktop machine had an nVidia card, so I'm thinking, sure, I'll just install the nVidia drivers like before and everything will work happily. Not so-- now the desktop and any other nVidia cards work great, but it seems to have completely disabled any other graphics cards. When the kernel module detects that an nVidia card isn't present, it shoots up this nasty little dialog box giving me the option to boot into "low graphics" mode, which doesn't even allow me to use the correct screen resolution, much less see the installed graphics card and try to configure a driver for it. Is there any way to configure Ubuntu (with the dreaded nVidia kernel module) so that it can use nVidia's drivers when an nVidia card is present, and default to the normal (not low-graphics) setup in other cases, so that it has a fair chance of using what's actually present? I'm not afraid to much with config files, I just don't know the underlying system well enough to feel comfortable diving in without a push in the right direction. Thanks guys!

    Read the article

  • SQL Server 2008 R2 mirroring failing

    - by andriusn
    I have two Windows 2008 R2 (Amazon EC2) instances running SQL Server 2008 R2. I use 9TB striped disks (9x1TB EBS volumes) for storage. One server is running as principal and second one as mirror. Both started from the same image, database and tlog files located on striped disk. Mirror server failed 3 times in last 2 months with errors: EventID 823 The operating system returned error 2(The system cannot find the file specified.) to SQL Server during a write at offset 0x00000048058a00 in file 'D:\TLogs***_log.ldf'. Additional messages in the SQL Server error log and system event log may provide more detail. This is a severe system-level error condition that threatens database integrity and must be corrected immediately. Complete a full database consistency check (DBCC CHECKDB). This error can be caused by many factors; for more information, see SQL Server Books Online. and EventID 1454 Database mirroring will be suspended. Server instance 'xxxxxxxxxx' encountered error 823, state 6, severity 24 when it was acting as a mirroring partner for database '***'. The database mirroring partners might try to recover automatically from the error and resume the mirroring session. For more information, view the error log for additional error messages. followed by EventID 19019 The MSSQLSERVER service terminated unexpectedly. After this rebooting instance is necessary to restore mirroring. First two times I thought it was hardware related (striped disk failure) and relaunched instance on new hardware. But the issue is back after few weeks again. It only affects mirror instances. Any help would be really appreciated. Thanks.

    Read the article

  • Setup.exe called from a batch file crashes with error 0x0000006

    - by Alex
    We're going to be installing some new software on pretty much all of our computers and I'm trying to setup a GPO to do it. We're running a Windows Server 2008 R2 domain controller and all of our machines are Windows 7. The GPO calls the following script which sits on a network share on our file server. The script it self calls an executable that sits on another network share on another server. The executable will imediatelly crash with an error 0x0000006. The event log just says this: Windows cannot access the file for one of the following reasons: there is a problem with the network connection, the disk that the file is stored on, or the storage drivers installed on this computer; or the disk is missing. Windows closed the program Setup.exe because of this error. Here's the script (which is stored on \\WIN2K8R2-F-01\Remote Applications): @ECHO OFF IF DEFINED ProgramFiles(x86) ( ECHO DEBUG: 64-bit platform SET _path="C:\Program Files (x86)\Canam" ) ELSE ( ECHO DEBUG: 32-bit platform SET _path="C:\Program Files\Canam" ) IF NOT EXIST %_path% ( ECHO DEBUG: Folder does not exist PUSHD \\WIN2K8R2-PSA-01\PSA Data\Client START "" "Setup.exe" "/q" POPD ) ELSE ( ECHO DEBUG: Folder exists ) Running the script manually as administrator also results in the same error. Setting up a shortcut with the same target and parameters works perfectly. Manually calling the executable also works. Not sure if it matters, but the installer is based on dotNETInstaller. I don't know what version though. I'd appreciate any suggestions on fixing this. Thanks in advance! UPDATE I highly doubt this matters, but the network share that the script is hosted in is a shared drive, while the network share the script references for the executable is a shared folder. Also, both shares have Domain Computers listed with full access for the sharing and security tabs. And PUSHD works without wrapping the path in quotes.

    Read the article

  • Windows Server 2003 DC hangs after network drivers update

    - by tcv
    Earlier today, we attempted to update the Broadcom BCM5716C network drivers on a Windows Server 2003. (Dell PowerEdge T310, FWIW). Since then we have not been able to boot the server in any normal mode. Safe Mode works. Safe Mode with Networking and regular bootups hang at "Applying Network Settings." I haven't tried Last Known Good Configuration nor have I tried Directory Services Restore Mode. I should also mention that the longest I've allowed "Applying Network Settings" was perhaps 30 minutes. I spoke to Dell since the server is under a basic warranty. They sent me the original Broadcom drivers. The trouble seems to be, however, that since I can only boot in Safe Mode, I can't install the application package as given. In safe mode, I receive the error: "The system administrator has set policies to prohibit this installation." I can install the drivers independently, but that doesn't allow the NICs to work. The most I've been able to get are Code 10 errors on each NIC. I plan to get back to the site tomorrow to attempt installation of a different NIC. I'm wondering what else I can try.

    Read the article

  • What GPT partition type to use for protecting DRBD metadata?

    - by Carsten Scholtes
    I'm planning to install a DRBD device on a (replicated) disk with two GPT partitions. DRBD requires some space for (preferentially "internal") metadata at the end of the underlying device. I'm hesitant to leave this space unpartitionend (or unformatted in a normal partition). I'd like to reserve an extra partition at the end of the underlying disk device for the metadata. (If I understand correctly, DRBD would not care about the partition or its type and could then use that space exclusively.) My question is: Which would be a suitable GPT partition type for such a metadata partition? It should not be a type interpreted while booting (such as EF00 EFI System). It should not be a type prone to be modified accidentialy by the booted OS (such as 8200 Linux swap, 8e00 Linux LVM, fd00 Linux raid). (The booted OS will be Ubuntu Linux 12.04.3.) It should not be a type indicating a normal filesystem (such as 0c01 or 8301), prone to be formatted correspondingly. It should not be a type requiring any special content in the partition (since the content is to be handled exclusively by DRBD). It should express the purpose of being reserved for something special (namely DRBD). (The types I listed are as provided by gdisk. I'm thinking about using some type unlikely to be used by the OS (maybe bf0a Solaris Reserved 4) or an invented(?) type such as fd01 (close to fd00 Linux raid…). Would something like this be suitable, too dangerous or even possible?)

    Read the article

  • Relax Linux - it's just me! (filesystem permissions)

    - by Xeoncross
    One of my favorite things about Linux is also the most annoying - file system permissions. In production machines and web servers I love how everything is so secure and locked down - but on development machines it really slows me down. I'll give one example out of the many that I discover weekly. Like most people, I dual-boot Ubuntu and Windows so I can continue using the Adobe CS4 suite. I often design web themes and other things while I'm still using windows. Later I'll boot into Ubuntu to take the themes and write the backend PHP for them. After mounting the windows C: drive partition I can copy the template files over so I can begin editing them. However, thanks to Linux desire to protect me I find that after coping the files I end up with a totally locked set of files where even I don't have read-write permissions. So after carful consideration about the tremendous risks that the HTML files pose to me - I chmod them so that I and apache can begin using them. Now given, the chmod process isn't that hard - but after you chmod enough files per day you get sick of doing it. I'm constantly creating, fetch, editing, and removing files from my user, git repos, php, or other random processes. This is a personal development machine after all. Everything changes on a day by day basis. So my question is, how can I get linux to relax about what I'm doing with my HTML/JS/PHP/TXT/SQL/etc. files so that I can work faster without constantly stopping to chmod things? I pinky-promise I won't hack into my account with an HTML file. ;)

    Read the article

  • Linux: prevent VNC from swapping like mad

    - by Weezy
    I'm accessing a MacMini (with MacOS X 10.4) from my Linux machine using VNC and there's an issue that is driving me crazy... My Linux machine has 4 GB of ram and I run a lot of various apps on it and I've got no issue at all. It's all snappy and don't hear the hard disk swapping/read/writing too often. Now with VNC, the hard disk is swapping like mad... When I'm moving things on the OS X desktop. So I was thinking of creating a ramdisk and forcing the temp VNC files to go into that ramdisk but the problem is I can't find any temp files. I've attempted to do that: #!/bin/bash while [ true ] do lsof | grep vnc done And eyeball parse the output to try to find some temp file: no luck. The VNC version I'm using is this one: $ vncviewer -version VNC Viewer Free Edition 4.1.1 for X - built Jan 30 2009 19:33:16 Copyright (C) 2002-2005 RealVNC Ltd. No matter how much data is coming from the Mac, there should be plenty of memory (4 GB of ram) so there's really no reason to swap like crazy. This is driving me mad. Any help as to how I could solve this problem is most welcome because this is literally driving me nuts.

    Read the article

  • SSD cache to minimize HDD spin-up time?

    - by sirprize
    short version first: I'm looking for Linux compatible software which is able to transparently cache HDD writes using an SSD. However, I only want to spin up the HDD once or twice a day (to write the cached data to the HDD). The rest of the time, the HDD should not be spinning due to noise concerns. Now the longer version: I have built a completely silent computer running Xubuntu. It has a A10-6700T APU, huge fanless cooler, fanless PSU, SSD. The problem is: it also has (and needs) a noisy HDD and I want to forbid spinning it up during the night. All writes should be cached on the SSD, reads are not needed in the night. Throughout every day, this computer will automatically download about 5 GB of data which will be retained for about a year, giving a total needed disk capacity of slightly less than 2 TB. This data is currently stored on a 3 TB noisy hard disk drive which is spinning day and night. Sometimes, I'll need to access some data from several months ago. However, most times I'll only need data from the last 14 days, which would fit on the SSD. Ideally, I'd like a transparent solution (all data on one filesystem) which caches all writes to the SSD, writing to the HDD only once a day. Reads would be served by the cache if they were still on the SDD, else the HDD would have to spin up. I have tried bcache without much success (using cache_mode=writeback, writeback_running=0, writeback_delay=86400, sequential_cutoff=0, congested_write_threshold_us=0 - anything missing?) and I read about ZFS ZIL/L2ARC but I'm not sure I can achieve my goal with ZFS. Any pointers? If all else fails, I will simply use some scripts to automatically copy files over to the big drive while deleting the oldest files from the SSD.

    Read the article

  • Tomcat uninstall problems

    - by Deepak
    Hi, I am using "apt-get remove tomcat6" to remove tomcat.It gives this outout and tomcat still running on my system: Reading package lists... Done Building dependency tree Reading state information... Done The following packages were automatically installed and are no longer required: seamonkey-gnome-support ocaml-base-nox libghc6-hsql-prof libgmp3-dev libffi-dev libtool libghc6-hsql-dev libgmpxx4ldbl ghc6-prof camlp4 ghc6 ledit ocaml-interp rhino libltdl-dev ocaml-nox Use 'apt-get autoremove' to remove them. The following packages will be REMOVED: tomcat6 tomcat6-admin tomcat6-examples 0 upgraded, 0 newly installed, 3 to remove and 1 not upgraded. After this operation, 2,400kB disk space will be freed. Do you want to continue [Y/n]? y Segmentation fault deepak@kalpna-desktop:~$ apt-get remove tomcat6 Reading package lists... Done Building dependency tree Reading state information... Done The following packages were automatically installed and are no longer required: seamonkey-gnome-support ocaml-base-nox libghc6-hsql-prof libgmp3-dev libffi-dev libtool libghc6-hsql-dev libgmpxx4ldbl ghc6-prof camlp4 ghc6 ledit ocaml-interp rhino libltdl-dev ocaml-nox Use 'apt-get autoremove' to remove them. The following packages will be REMOVED: tomcat6 tomcat6-admin tomcat6-examples 0 upgraded, 0 newly installed, 3 to remove and 1 not upgraded. After this operation, 2,400kB disk space will be freed. Do you want to continue [Y/n]? y Segmentation fault What is the way to re-install tomcat on ubuntu. Regards D

    Read the article

  • A tiered approach to cloning linux partitons

    - by Djurdjura
    I'm looking at a strategy for cloning Linux (root) partitions without having to use a Live CD. Literature suggests rightly that the source and target partitions must be umounted to be able to get a clean clone. This assumes that you need to use a LiveCD. I was wondering if instead of requiring a LiveCD, if using a 3rd partition that would emulate the LiveCD functionality, if we can't achieve the same functionality. In other words, at a high level a system with 3 partitions (all bootable): Rescue Partition (LiveCD emulation) Running Partition (Source) Backup Partition (Destination) All 3 partitions are LVMS. When it's time to clone the source partition to the backup (destination) partition, we would boot to the rescue partition, unmount the other 2 partitions (is it required?), run disk check on the source, copy to the destination (dd or simple copy to avoid replicating the defragmentation from the source), run disk check on the destination partition, update Grub menu list to force boot from either partition, and reboot into that partition. My question, is it an approach that you'd recommend? MBR in all this? Any gotchas or extra checks required? Thanks, D. PS. On recommendation from members, posting here instead of stackoverflow.com.

    Read the article

  • Upgrading Visio 2000 to Visio 2007

    - by dirtside
    I have Microsoft Visio 2000 SR 1, and recently purchased Microsoft Office Visio Standard 2007 with the understanding (supported by the product info and some other research) that I'd be able to upgrade. However, when I install 2007, it tells me it can't find a previous install of Visio, but... it's right there! Here's the exact message: "Setup can't find a version of Microsoft Office on your computer. If Office is installed on a disk or network share, click the browse button to select the appropriate disk or share... (etc.)" No matter which directory or drive I pick (various Office installs, the old Visio install, various subdirectories) it gives the following message: "The path you have chosen does not point at a qualifying upgradeable product. Click 'Retry' to try again or 'Cancel' to quit setup." Any ideas? This is a legit copy of Visio 2007 (purchased from Amazon) and the copy of Visio 2000 is legit as well. I'm not sure what exactly the installer is looking for that it would consider a "qualifying upgradeable product". A specific file?

    Read the article

  • How do I run a stable Windows XP kvm guest on Ubuntu 10.04?

    - by Jean-Paul Calderone
    I have three Windows XP guests running on a recently upgraded 64-bit Ubuntu 10.04 system. Occasionally (on the order of once every few days), one of the guests will become non-responsive and the kvm process on the host which is running that guest will start consuming 100% CPU. It will continue to do so until it is killed. When restarted, it will be fine for a while, and then the issue repeats. The kvm command line used to run all three guests is this: /usr/bin/kvm -S -M pc-0.12 -enable-kvm -m 1024 -smp 1 -name bigdog21vmxp1 \ -uuid ea47ff84-125b-16f7-9a4d-a6d0d8bab46a \ -chardev socket,id=monitor,path=/var/lib/libvirt/qemu/bigdog21vmxp1.monitor,server,nowait \ -monitor chardev:monitor \ -localtime \ -boot c \ -drive file=/var/lib/libvirt/images/windowsxp-1.qcow2,if=ide,index=0,boot=on,format=qcow2 \ -net nic,macaddr=54:52:00:02:06:0e,vlan=0,name=nic.0 \ -net tap,fd=58,vlan=0,name=tap.0 \ -chardev pty,id=serial0 \ -serial chardev:serial0 \ -parallel none \ -usb \ -usbdevice tablet \ -vnc 127.0.0.1:1 \ -k en-us \ -vga cirrus \ -soundhw es1370 Why do the systems misbehave this way sometimes? And what configuration can I change in order to fix it? Or, if the problem is due to a bug in kvm, what is the process for isolating a kvm failure so that the developers have a chance of fixing it?

    Read the article

  • Selenium server won't start

    - by moff
    I'm getting the following error when trying to start selenium: C:\Temp\selenium-server-1.0.3java -jar selenium-server.jar 22:02:07.615 INFO - Java: Sun Microsystems Inc. 16.0-b13 22:02:07.617 INFO - OS: Windows 7 6.1 x86 22:02:07.625 INFO - v2.0 [a2], with Core v2.0 [a2] 22:02:07.811 INFO - RemoteWebDriver instances should connect to: http://127.0.0. 1:4444/wd/hub 22:02:07.813 INFO - Version Jetty/5.1.x 22:02:07.815 INFO - Started HttpContext[/selenium-server/driver,/selenium-server /driver] 22:02:07.817 INFO - Started HttpContext[/selenium-server,/selenium-server] 22:02:07.818 INFO - Started HttpContext[/,/] 22:02:07.866 INFO - Started org.openqa.jetty.jetty.servlet.ServletHandler@2bbd86 22:02:07.867 INFO - Started HttpContext[/wd,/wd] 22:02:07.870 WARN - Failed to start: [email protected]:4444 Exception in thread "main" org.openqa.jetty.util.MultiException[java.net.SocketE xception: Unrecognized Windows Sockets error: 0: JVM_Bind] at org.openqa.jetty.http.HttpServer.doStart(HttpServer.java:686) at org.openqa.jetty.util.Container.start(Container.java:72) at org.openqa.selenium.server.SeleniumServer.start(SeleniumServer.java:3 96) at org.openqa.selenium.server.SeleniumServer.boot(SeleniumServer.java:23 4) at org.openqa.selenium.server.SeleniumServer.main(SeleniumServer.java:19 8) java.net.SocketException: Unrecognized Windows Sockets error: 0: JVM_Bind at java.net.PlainSocketImpl.socketBind(Native Method) at java.net.PlainSocketImpl.bind(Unknown Source) at java.net.ServerSocket.bind(Unknown Source) at java.net.ServerSocket.(Unknown Source) at org.openqa.jetty.util.ThreadedServer.newServerSocket(ThreadedServer.j ava:391) at org.openqa.jetty.util.ThreadedServer.open(ThreadedServer.java:477) at org.openqa.jetty.util.ThreadedServer.start(ThreadedServer.java:503) at org.openqa.jetty.http.SocketListener.start(SocketListener.java:204) at org.openqa.jetty.http.HttpServer.doStart(HttpServer.java:716) at org.openqa.jetty.util.Container.start(Container.java:72) at org.openqa.selenium.server.SeleniumServer.start(SeleniumServer.java:3 96) at org.openqa.selenium.server.SeleniumServer.boot(SeleniumServer.java:23 4) at org.openqa.selenium.server.SeleniumServer.main(SeleniumServer.java:19 8) Java is installed: C:\Temp\selenium-server-1.0.3java -version java version "1.6.0_18" Java(TM) SE Runtime Environment (build 1.6.0_18-b07) Java HotSpot(TM) Client VM (build 16.0-b13, mixed mode, sharing) Thanks in advance

    Read the article

  • Toshiba External Hard Drive freezes computer

    - by Ephraim
    I bought a Toshiba Canvio Basics E05A032BAU2XK Portable External 320GB 2.5 Hard Drive: My computer has two Os's on it Win7 and Win XP. I need both. The main one I use is XP. When booting my computer in any OS the computer and hard drive work fine. The same holds true for plugging in the hard drive while running Win7. However, when running WinXP, if the hard drive gets plugged in the computer freezes(my main point is that the HD is portable so it is essential that it does not do this, as I said I usually run XP). After reading some online forums I was informed that there is a compatibility issue with the newest version of Eset Smart Security(I still don't understand this because it works fine in Win7 or when connected on boot...). I disabled the AV and plugged in the HD... Walla! The comnputer did not freeze. However the disk is not recognized in explorer or disk management. In device manager I removed the device and did a scan and installation of device failed. It pretty much sounds like a driver issue but I cannot find any drivers for this HD. In fact, Toshiba claims that there are no downloadable drivers for it and that XP should take care of the drivers itself. What to do? As far as I can tell, all other USB devices work just fine on both OS. Please Help!

    Read the article

  • What do you upgrade to make games load faster? [on hold]

    - by Superbest
    Let's say you have a relatively modern game like Shogun 2. The loading screens take several minutes. This bothers you and you'd like to improve it. What is actually going on when loading screens are up? I'm guessing assets are being loaded into memory from disk, and possibly being decompressed first. However, what is actually causing the slow down? The memory? Mainboard? CPU? HDD? If you had $100 to spend on upgrades and your only goal is to speed up loading screens without reducing other performance, what component of the computer does it make sense to upgrade for maximum benefit? If your answer is "it depends on the existing setup", what sort of benchmarks would you run to determine what is causing the bottleneck? What if you had $500 instead? I give the two budgets for context. I am not asking for actual recommendations about which component to buy (nor are the numbers supposed to be rigid limits), but what features are important when shopping for components with small and large budgets (a large budget could allow buying multiple components which are not so good on their own, but work particularly well together). I mention Shogun 2 as an example, but I'm asking about reducing overall loading times, across all games, not just one game. Therefore, "put it on a solid state disk" probably won't be good solution, because putting every game on your SDD will quickly fill it up.

    Read the article

  • Extend RAID 1 (HP SmartArray P410i) running Linux

    - by Oliver
    I took over a fairly simple server setup with the following RAID 1 config running Ubuntu 11.10 (Kernel 3.0.0-12-server x86_64): => ctrl all show config Smart Array P410i in Slot 0 (Embedded) (sn: removed) array A (SAS, Unused Space: 1335535 MB) logicaldrive 1 (279.4 GB, RAID 1, OK) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 1 TB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 1 TB, OK) Initially there were two 300GB disks that got replaced by 1TB disks and I now have to extend the logical volume to use that extra space. However, when trying to do so I get the following warning: => ctrl slot=0 ld 1 modify size=max Warning: Extension may not be supported on certain operating systems. Performing extension on these operating systems can cause data to become inaccessible. See ACU documentation for details. Continue? (y/n) Is it safe to say yes or am I at risk of corrupting the file system / loosing data? Rearranging and extending the file system afterwards shouldn't be an issue as I can take the server offline and boot from a gparted live disk. Here's the config of the RAID controller in use: => ctrl all show detail Smart Array P410i in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Serial Number: removed RAID 6 (ADG) Status: Disabled Controller Status: OK Hardware Revision: Rev C Firmware Version: 5.12 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 15 secs Surface Scan Mode: Idle Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 0 secs Cache Board Present: False Drive Write Cache: Disabled SATA NCQ Supported: True And the partition table: Number Start End Size Type File system Flags 1 1049kB 274GB 274GB primary ext4 boot 2 274GB 300GB 25.8GB extended 5 274GB 300GB 25.8GB logical linux-swap(v1)

    Read the article

  • Acer recovering windows vista

    - by Charlie Pigarelli
    My computer history is very long even of my computer has 4 years of life. An year ago I installed Windows 7 on this acer m1610 that had Vista before. My technic left me 2 recovery disc for "acer vista" before updating it to Windows 7. Then the computer had some trouble. The graphic card broke and we decided to use another computer. Yesterday I had the great idea to fuse the two computer to have a better one... So I moved the graphic card of the latter computer to the acer and everything gone well. Then the trouble of speed, it had before, come back. So I decided to reinstall the very first Windows: Vista back again. I booted the computer with those 2 DVD-R my technic left me and at the end of the process it asked me to insert "the backup cd number one or the system disk". I found 2 original Acer "Blank Recovery Disc" DVD-R and tried with those: rejected. Tried with empty DVD-+R: rejected. I tried with CDs: rejected. I don't have any system disc with me. Except for those 2 DVD-R my technic left me. What am I supposed to do now? I even tried with these fantomatic alt+f9/f10 that should start the recovery without any disc... But nothing happened. PS: the installation cannot complete if I do not insert the right disk. (The recovery disc uses Acer eRecovery Management as recovery software.

    Read the article

  • SQL Server 2005 standard filegroups / files for performance on SAN

    - by Blootac
    Ok so I've just been on a SQL Server course and we discussed the usage scenarios of multiple filegroups and files when in use over local RAID and local disks but we didn't touch SAN scenarios so my question is as follows; I currently have a 250 gig database running on SQL Server 2005 where some tables have a huge number of writes and others are fairly static. The database and all objects reside in a single file group with a single data file. The log file is also on the same volume. My interpretation is that separate data files should be used across different disks to lessen disk contention and that file groups should be used for partitioning of data. However, with a SAN you obviously don't really have the same issue of disk contention that you do with a small RAID setup (or at least we don't at the moment), and standard edition doesn't support partitioning. So in order to improve parallelism what should I do? My understanding of various Microsoft publications is that if I increase the number of data files, separate threads can act across each file separately. Which leads me to the question how many files should I have. One per core? Should I be putting tables and indexes with high levels of activity in separate file groups, each with the same number of data files as we have cores? Thank you

    Read the article

  • Windows 7 64-bit installation from alternative media (no DVD/USB Flash drive)

    - by Niels Willems
    Greetings I currently have Windows 7 x86 installed on my computer. I want to install Windows 7 x64 on a different partition on my computer. However there is a little issue, I cannot run the x64 install from Windows 7 x86 which I currently have. I was planning to Install Windows 7 x64 on another partition to then boot up from that partition to install it on the partition I actually want my OS on. Once that is complete I could just format the partition from the Windows 7 x64 that I didn't need anymore. But the installer will not run from the x86 version of Windows 7 even though I do not want to upgrade that Windows directly. The reason I'm doing this in such a weird way is that my optical drive is broken and I'm really not into buying a new one since I would use it like once every year or so. I also don't have a USB Flash Drive which is big enough to hold the installation files. As far as I'm aware I cannot use an external hard drive such as this one, which I do have. Are there any alternatives in which I can install Windows 7 x64 or am I forced into buying a USB Flash Drive or new optical drive? Thank you in advance for your replies. Edit: This picture shows my current partitions on my laptop. I want to get Windows 7 x64 on the C partition but have to install it first on the F partition to then boot up the F partition windows to format C and install x64 on that one. My external drive is J. Edit 2: No alternative computer which has a DVD drive, install files are located on an iso from MA3D. To install my 32 bit version I mounted the ISO in Daemon Tools to replace my Windows Vista but since I cannot run 64 bit into my 32 bit OS this doesn't work.

    Read the article

  • Very slow browsing shared folder XP client/host

    - by Ickster
    I have a pretty straightforward setup where I'm storing media files on an XP pro machine, and sharing the folder to be accessed by other XP pro machines around the house. (Typically, there's only one client accessing the share at a time, although there may be several with the share mounted.) It's been working just fine for years, but I've recently started having some problems. A couple of days ago, the host PC had power disconnected while it was running. It was restarted and everything seemed fine initially, but since then browsing the shared folder from client machines has been extremely slow and actually reading data is all but impossible. The problem exists in every access method I've tried: Windows Explorer, VLC dialogs, command line, etc. My first thought was that the disk was experiencing problems, but there are no problems viewing the files locally on the host machine. My second thought was that there was a network problem on the host machine, so I removed and reinstalled drivers for the NIC with no change. My third thought was that there might've been a problem elsewhere on the network, so I swapped out hardware to no avail. I'm regrouping and trying to come up with a methodical approach to figuring out what might be wrong. I would of course be thrilled if you can suggest specific problems (Microsoft KB articles, etc.) that I might check, but I'm not expecting a silver bullet. If you can help me outline an approach to identify the problem (including recommended tools, e.g., disk checkers, network analyzers, etc.) I'd greatly appreciate it.

    Read the article

  • Multicast image restoration with adaptive speed

    - by Clinton Blackmore
    I'm curious to know if there are any tools for restoring disk images (or even transferring files) via multicast -- for any platform, especially if the project has source available -- where the multicast rate adjusts itself on the fly. On the Mac, all multicast solutions I am aware of (such as Deploy Studio, and NetRestore before it) make use of multicast ASR (apple software restore), which has one glaring deficiency -- you have to set the multicast speed before you start sending a disk image over the network, and that speed is locked in. Either your clients can keep up and restore, or they can't*. It seems to me that it must be possible for the multicast server to adjust the data rate, so you basically say "start sending this image", clients connect, and, if they can't keep up, they tell the server so it slows down. (Likewise, I'd expect the server to try speeding up if no client is having difficulties keeping up, and I'd expect to be able to cap that maximum throughput so that other network activities can go on without being resource starved.) So, what sort of tools are out there? For Linux? Windows? Is there something for the Mac I've overlooked. [It just kills me that it is true that, by the time you get multicast up and going at a good speed to restore a lab, you could've unicasted the data to all the computers and be done.] * There is a little leeway involved. I think individual clients can say, "I missed a little bit of data" and get it, and they can opt to listen in the next time the image is sent over the network, but on the whole, if they missed it the first go round, you have to image the machine again, and there is no time savings.

    Read the article

  • VNC failure on Xen

    - by BCable
    The following config works and creates a good VM in Xen: # Kernel Setup kernel = "/boot/vmlinuz-2.6.18.8-xenU" # Memory memory = "256" # Disk disk = [ "file:/opt/xen/domains/110/sda1.img,sda1,w", "file:/opt/xen/domains/110/swap.img,sda2,w" ] # container name name = "110" hostname = "boo" # Networking vif = ["type=ieomu, bridge=xenbr0"] # VNC vnc = 1 #vfb = [ 'type=vnc,vncdisplay=2,vnclisten=0.0.0.0,vncpasswd=110' ] # Behavior Settings root = "/dev/sda1" extra = "fastboot" But when I uncomment the VFB line, I get the following error after it hangs for at least 30 seconds: [root@customer 110]# xm create boo.cfg Using config file "./boo.cfg". Error: Device 0 (vkbd) could not be connected. Hotplug scripts not working. Any ideas? Part two of this question: Sometimes it actually works, and a port is opened. When this happens, nmap shows the VNC ports open and I can connect via the VNC client, but it just hangs at "Connection established." and no VNC display shows up. I've tried multiple VNC clients (TightVNC, TightVNC Java Console, RealVNC), but they all fail to connect. Does VNC through Xen require X to be started in order to function? I was under the impression that it would show the console screen, so I'm confused as to why all these issues are occurring. Thanks!

    Read the article

  • Computer locking up, looking for bootable hardware diagnostic tool.

    - by Carl Menke
    Well today I helped my friend build a computer. All went pretty well until we got to installing Win7. Thing is, we thought, it was crashing constantly. I adjusted pretty much every setting in the BIOS and removed as much hardware as possible to try and prevent a crash. No dice. So far I've tried running an Ubuntu live cd without the harddrive installed. Nope, crashed on boot. And then I just tried Microsoft's ram utility disk and it eventually locked up on that (the ram passed though). So it seems to me like it's either the CPU (AMD PhenomII x3) or the motherboard that could be bad, but I don't know how to test them individually for problems. I thought it could be a overheating issue, but the BIOS reports that the CPU temp is fine idling around 34C. Any advice or diagnostic disk that could help me out? TL;DR: Computer locks up frequently during use (cannot even boot/install an operating system), memory is fine, probably CPU or Mobo, BIOS says CPU temps are fine. What should I try?

    Read the article

  • ubuntu - Best way of repartitioning a (running) production server

    - by egarcia
    I've got an (externally hosted) production server running Ubuntu LTS. It serves webpages (rails) and has an svn repository accesible through Apache, and a PostgreSQL db. I've got ssh access to the server and root privileges. Most of the "interesting" stuff is located in /var/ : svn repositories are inside /var/svn, web pages under /var/www, etc. Yesterday I was curious about how much disk space had it left, so I did the following: $ df -h Filesystem Size Used Avail Use% Mounted on /dev/md1 950M 402M 500M 45% / varrun 990M 64K 990M 1% /var/run varlock 990M 0 990M 0% /var/lock udev 990M 76K 989M 1% /dev devshm 990M 0 990M 0% /dev/shm /dev/md5 4.7G 668M 4.1G 15% /usr /dev/md6 4.7G 1.4G 3.4G 29% /var /dev/md7 221G 28M 221G 1% /home none 990M 4.0K 990M 1% /tmp My 'var' partition, which holds most of the interesting part, is only 4.7G big. The /home/ partition, on the other hand, is 221G, but it is mostly unused. I should have checked the disk layout before starting installing stuff. Ideally I would need /var/ and /home/ to be "switched" - /home/ should be the one with 4.7G, and /var/ the one with 221G. Is there a way to solve this without having to reinstall the whole thing?

    Read the article

< Previous Page | 322 323 324 325 326 327 328 329 330 331 332 333  | Next Page >