Daily Archives

Articles indexed Thursday October 4 2012

Page 8/16 | < Previous Page | 4 5 6 7 8 9 10 11 12 13 14 15  | Next Page >

  • How do I add install my own LocationProvider?

    - by gregm
    I would like to create my own implementation of a LocationProvider, there seems to be a way to add a "mock" provider, but that isn't exactly what I want. http://developer.android.com/reference/android/location/LocationManager.html There also appears to be a permission called: android.permission.INSTALL_LOCATION_PROVIDER But there is no documentation about how to use this permission. How do I register a new location provider?

    Read the article

  • Adding Netem Filter Rules

    - by fontsix
    iam new in programming and using linux. My Question is, is it possible to add Netem Filter Rules later ? I want to create an PHP-Interface for Netem and I don't know how much filters were required. This should be some kind of dynamically. In Example : A user with a static IP starts an Netem Command (Latency) with PHP Interface this means these five command werde executed by php in the first step $classid = 11; $handle = 10; "sudo tc qdisc add dev eth0 handle 1: root htb"; "sudo tc class add dev eth0 parent 1: classid 1:1 htb rate 100Mbps"; "sudo tc class add dev eth0 parent 1:1 classid 1:$classid htb rate 100Mbps"; "sudo tc qdisc add dev eth0 parent 1:$classid handle $handle: netem delay 100ms"; "sudo tc filter add dev eth0 protocol ip parent 1:0 prio 3 u32 match ip dst $dest flowid 1:$classid"; Now, if there would be a second user who wants to use Netem independent of the first user, i only want to execute the last 3 commands, like "sudo tc class add dev eth0 parent 1:1 classid 1:$classid htb rate 100Mbps"; "sudo tc qdisc add dev eth0 parent 1:$classid handle $handle: netem delay 100ms"; "sudo tc filter add dev eth0 protocol ip parent 1:0 prio 3 u32 match ip dst $dest flowid 1:$classid"; There is an Algorithmus for increasing variables $classid and $handle. This should work. Now my Question: Is it possible only to add these 3 commands to add a new class with new qdisc and a new filter rule ? Or how can i realize it ? The Apache Error_log tells me "sh: line 1: flowid: command not found" but i can't find any mistake. I hope you could help Best regards fontsix

    Read the article

  • who are the goldengate extract users

    - by sharif
    I am setting up golden gate, this installation guide is quite confusing as it refers to steps which have not been done or already done previously. I am on step 4.8.1 on the ''oracle installation guide''. I is asking for ''Extract'' user name. I do not recall creating such other than the goldengate user. Also what are the other four users it refers to as in 4.6 Extract Replicat Manager DEFGEN what is the usernames for each of these in the db?

    Read the article

  • Mysql dump of slave w/o missing Master data

    - by zooooommmm
    I am fairly new to the whole replication process of mysql so this may be an easy question to answer. I have a master and and slave. I need to set up another slave so obviously I will need to make the dump from the current slave because I CAN NOT take the master offline for a second. How can I be sure that during the time I am making the dump of the current slave database that I do not miss any master data that is newly created over that time? Thanks all.

    Read the article

  • I am looking for a tool to measure or detect "unresponsiveness" of a desktop PC

    - by Tom H
    I have a client that provides some server systems to a hospital, and a support ticket was raised that the desktop application was hanging waiting for the server. We did some extensive testing and its pretty clear that the server is responsive, and the network is fine, and that the problem is on the client end. (no requests are received during the hang etc...) We take a look at the desktop machines and they should be fine, so we raise tickets with the software vendor who says that it must be the hardware, the hardware company says that it is the software, etc etc Anyway, so talking to the nurses, they say that these machines often "hang" for 30 seconds at a time, and sometimes during important moments where they need to get data for a patient who is unwell, such as charts and status. So I want to stick a client on these machines that would be able to detect arbitrary "unresponsiveness" of the keyboard/mouse and log that for analysis later. Obviously I am wary to suggest some application that takes resources and makes the problem even worse, so I would interested to see any tools that would detect these (is it correct to say that the keyboard interrupts are being discarded?) scenarios by looking for the OS discarding the interrupts, or whatever is appropriate here. so go on then serverfault, here is your chance to save a life.... ;-) Edit: I am starting to think that some of the tools associated with real time systems might be appropriate, at least as a diagnostic.

    Read the article

  • Modify MDT wizard to automate computer naming

    - by Jeramy
    I originally posted this question to StackOverflow, but upon further consideration it might be more appropriate here. Situation: I am imaging new systems using MDT Lite-Touch. I am trying to customize the wizard to automate the naming of new systems so that they include a prefix "AG-", a department code which is selected from a drop-down box in the wizard page (eg. "COMM"), and finally the serial number of the computer being imaged, so that my result in this case would be "AG-COMM-1234567890" Status: I have banged away at this for a while but my Google searches have not turned up answers, my trial-and-error is not producing useful error messages and I think I am missing some fundamentals of how to get variables from the wizard page into the variables used by the lite-touch wizard. Progress: I first created the HTML page which I will include below and added a script to the page to concatenate the pieces into a variable called OSDComputername which, for testing, I could output in a msgbox and get to display correctly. The problem with this is I don't know how to trigger the script then assign it to the OSDComputername variable that is used throughout the rest of the Light-Touch process. I changed the script to a function and added it to DeployWiz_Initization.vbs then used the Initialization field in WDS to call it. I'll include the function below. The problem with this is I would get "Undefined Variable" for OSDComputername and I am not sure it is pulling the data from the HTML correctly. I tried adding the scripting into the customsettings.ini file after the "OSDComputername=" This resulted in the wizard just outputting my code in text as the computer name. I am now trying adding variables to "Properties=" (eg.DepartmentName) in the customsettings.ini, pulling thier value from the HTML Form and setting that value to the variable in my function in DeployWiz_Initization.vbs and calling them after "OSDComputername=" in the fashion "OSDComputername="AG-" & %DepartmentName%" in customsettings.ini I am rebuilding right now and will see how this goes Any help would be appreciated. The HTML page: <HTML> <H1>Configure the computer name.</H1> <span style="width: 95%;"> <p>Please answer the following questions. Your answers will be used to formulate the computer's name and description.</p> <FORM NAME="TestForm"> <p>Departmental Prefix: <!-- <label class=ErrMsg id=DepartmentalPrefix_Err>* Required (MISSING)</label> --> <SELECT NAME="DepartmentalPrefix_Edit" class=WideEdit> <option value="AADC">AADC</option> <option value="AEM">AEM</option> <option value="AIP">AIP</option> <option value="COM">COM</option> <option value="DO">DO</option> <option value="DSOC">DSOC</option> <option value="EDU">EDU</option> <option value="EPE">EPE</option> <option value="ITN">ITN</option> <option value="LA">LA</option> <option value="OAP">OAP</option> <option value="SML">SML</option> </SELECT> </p> <p><span class="Larger">Client's Net<u class=larger>I</u>D:</span> <INPUT NAME="ClientNetID" TYPE="TEXT" ID="ClientNetID" SIZE="15"></p> <p>Building: <!-- <label class=ErrMsg id=Building_Err>* Required (MISSING)</label> --> <SELECT NAME="Building_Edit" class=WideEdit> <option value="Academic Surge Facility A">Academic Surge Facility A</option> <option value="Academic Surge Facility B">Academic Surge Facility B</option> <option value="Caldwell">Caldwell</option> <option value="Kennedy">Kennedy</option> <option value="Roberts">Roberts</option> <option value="Warren">Warren</option> </SELECT> </p> <p> <span class="Larger">Room <u class=larger>N</u>umber:</span> <input type=text id="RoomNumber" name=RoomNumber size=15 /> </p> </FORM> </span> </HTML> The Function: Function SetComputerName OSDComputerName = "AG-" & oEnvironment.Item("DepartmentalPrefix_Edit") ComputerDescription = oEnvironment.Item("DepartmentalPrefix_Edit") & ", " & oEnvironment.Item("ClientNetID") & ", " & oEnvironment.Item("RoomNumber") & " " & oEnvironment.Item("Building_Edit") End Function

    Read the article

  • How to open http for linux server

    - by wtfcoder
    I am a Windows (IIS) software engineer, but recently I've been thrown into a Linux server admin role until we can find someone to fill the position. I am not ashamed to admit I have no idea what I am doing. Currently the problem I am trying to solve is that the server is only responding to https requests. However, we need it to respond to standard http requests as well. We don't really have anything that needs to stay secure on its way to the requester. I am running redhat linux via bash. If anyone could tell me how to enable http requests I would really appreciate it! Thanks Please make sure your response is fairly step by step as I have minimal command line experience :/

    Read the article

  • Flexible virtualization infrastructure Design with libvirt

    - by Lessfoe
    I'm going to install a CentOS6 Server with Virtualization ( libvirtd ) capabilities on a DELL Server with Hardware RAID5 of around 6T of disk space ( It has 4x2T disks in a PERC700 RAID Controller ). I'm going then to install some guests which requires few resources except one that needs 500GB of disk space, 8/16GB of RAM and good performances. I was thinking about file images for guests storage but I'm not sure about the 500GB VM what needs good performances so that an LVM device could be better. So my question is what would be the best layout concerning: RAID setup ( RAID5, RAID1 + 1 disk for OS only. ) disk partitioning ( using the entire disk/ leave free space for future use and extending it with LVM ) guests storage management ( LVM devices or file images ( considering the 500GB VM that is performance demanding ) or mixed ) Where to put guests storage? /var/lib/libvirt/images or maybe in a custom dir separated from system /home/VMs Thanks in advance for any hint.

    Read the article

  • SQL Server Logs: missing date ranges

    - by Jeff
    I need to be able to export SQL Server logs into CSV files, which I can easily do with the export function. However in doing so I've noticed there's a range of dates missing from the SQL Server logs in Management Studio, two months actually. I'm wondering where these logs might be found, and if it's possible to reload them so I can view and then export them. They're strictly for informational purposes, but I do need them. Thanks in advance!

    Read the article

  • MySQL replication ignore data changes but not table structure changes

    - by Ed Manet
    Is there a way to setup MySQL replication so that CREATE TABLE and ALTER TABLE statements get replicated but INSERT, DELETE and UPDATE statements do not? I've got replication working fine and have several tables that are ignored as per the requirements. But we have a requirement that the slaves have an empty copy of the ignored table. We create those empty copies before we start replicating. Since the table is ignored, table structure changes don't get passed down from the master to the slave's empty copy. I know it's a strange requirement.

    Read the article

  • htaccess redirect from wordpress page to a php page

    - by JustAnil
    I have recently had to change a URL on a website (in PHP on Apache). The old URL is: http://content.mywebsite.org.uk/hidden/discounts/ When a user visits the above link. The new URL is: http://www.mywebsite.org.uk/charity_benefits.php I have tried variants of the following (and some others), but its just not working for me. RewriteCond %{REQUEST_URI} ^/hidden/discounts/$ [NC] RewriteRule ^/hidden/discounts/$ /charity_benefits.php [R=302,L,NC] I need the redirect to redirect to www mywebsite.org.uk. (Notice the www! Its important!). So basically, a simple redirect from the old page to the new page. (Which are on different subdomains (OLD: content., NEW: www.) which are hosted on the same server).

    Read the article

  • Garbled text in Screen [closed]

    - by Prabin Dahal
    The graphical Interface in my system is garbled with some text. At the beginning I thought it was due to java and tomcat that I installed. But after removing java and tomcat, it is still the same. I am using ubuntu server and i have installed xfce desktop environment with oboard softkey I have added my dmesg output to this message. What is the problem here. I am not able to figure it out. Thank you for your help. Prabin [ 0.390936] usbcore: registered new interface driver usbfs [ 0.391006] usbcore: registered new interface driver hub [ 0.391147] usbcore: registered new device driver usb [ 0.391580] PCI: Using ACPI for IRQ routing [ 0.400509] PCI: pci_cache_line_size set to 64 bytes [ 0.400669] reserve RAM buffer: 000000000009ec00 - 000000000009ffff [ 0.400681] reserve RAM buffer: 000000007f597000 - 000000007fffffff [ 0.400699] reserve RAM buffer: 000000007f6f0000 - 000000007fffffff [ 0.401135] NetLabel: Initializing [ 0.401155] NetLabel: domain hash size = 128 [ 0.401168] NetLabel: protocols = UNLABELED CIPSOv4 [ 0.401212] NetLabel: unlabeled traffic allowed by default [ 0.401466] HPET: 3 timers in total, 0 timers will be used for per-cpu timer [ 0.401494] hpet0: at MMIO 0xfed00000, IRQs 2, 8, 0 [ 0.401520] hpet0: 3 comparators, 64-bit 14.318180 MHz counter [ 0.408228] Switching to clocksource hpet [ 0.434341] AppArmor: AppArmor Filesystem Enabled [ 0.434447] pnp: PnP ACPI init [ 0.434531] ACPI: bus type pnp registered [ 0.434784] pnp 00:00: [bus 00-ff] [ 0.434794] pnp 00:00: [io 0x0cf8-0x0cff] [ 0.434804] pnp 00:00: [io 0x0000-0x0cf7 window] [ 0.434813] pnp 00:00: [io 0x0d00-0xffff window] [ 0.434822] pnp 00:00: [mem 0x000a0000-0x000bffff window] [ 0.434831] pnp 00:00: [mem 0x00000000 window] [ 0.434840] pnp 00:00: [mem 0x80000000-0xffffffff window] [ 0.435018] pnp 00:00: Plug and Play ACPI device, IDs PNP0a08 PNP0a03 (active) [ 0.435526] pnp 00:01: [mem 0xe0000000-0xefffffff] [ 0.435537] pnp 00:01: [mem 0x7f700000-0x7f7fffff] [ 0.435545] pnp 00:01: [mem 0x7f800000-0x7fffffff] [ 0.435554] pnp 00:01: [mem 0xfee00000-0xfeefffff] [ 0.435727] system 00:01: [mem 0xe0000000-0xefffffff] has been reserved [ 0.435754] system 00:01: [mem 0x7f700000-0x7f7fffff] has been reserved [ 0.435775] system 00:01: [mem 0x7f800000-0x7fffffff] has been reserved [ 0.435796] system 00:01: [mem 0xfee00000-0xfeefffff] has been reserved [ 0.435818] system 00:01: Plug and Play ACPI device, IDs PNP0c01 (active) [ 0.436233] pnp 00:02: [io 0x0000-0xffffffffffffffff disabled] [ 0.436245] pnp 00:02: [io 0x0000-0xffffffffffffffff disabled] [ 0.436414] system 00:02: Plug and Play ACPI device, IDs PNP0c02 (active) [ 0.436512] pnp 00:03: [io 0x0060] [ 0.436521] pnp 00:03: [io 0x0064] [ 0.436548] pnp 00:03: [irq 1] [ 0.436682] pnp 00:03: Plug and Play ACPI device, IDs PNP0303 PNP030b (active) [ 0.436825] pnp 00:04: [irq 12] [ 0.436958] pnp 00:04: Plug and Play ACPI device, IDs PNP0f03 PNP0f13 (active) [ 0.437835] pnp 00:05: [io 0x03f8-0x03ff] [ 0.437861] pnp 00:05: [irq 4] [ 0.437870] pnp 00:05: [dma 0 disabled] [ 0.438142] pnp 00:05: Plug and Play ACPI device, IDs PNP0501 (active) [ 0.439014] pnp 00:06: [io 0x02f8-0x02ff] [ 0.439036] pnp 00:06: [irq 3] [ 0.439045] pnp 00:06: [dma 0 disabled] [ 0.439297] pnp 00:06: Plug and Play ACPI device, IDs PNP0501 (active) [ 0.439346] pnp 00:07: [io 0x0000-0x000f] [ 0.439355] pnp 00:07: [io 0x0081-0x0083] [ 0.439363] pnp 00:07: [io 0x0087] [ 0.439371] pnp 00:07: [io 0x0089-0x008b] [ 0.439380] pnp 00:07: [io 0x008f] [ 0.439388] pnp 00:07: [io 0x00c0-0x00df] [ 0.439563] system 00:07: Plug and Play ACPI device, IDs PNP0c01 (active) [ 0.439617] pnp 00:08: [io 0x0070-0x0077] [ 0.439639] pnp 00:08: [irq 8] [ 0.439751] pnp 00:08: Plug and Play ACPI device, IDs PNP0b00 (active) [ 0.439788] pnp 00:09: [io 0x0061] [ 0.439893] pnp 00:09: Plug and Play ACPI device, IDs PNP0800 (active) [ 0.439977] pnp 00:0a: [io 0x0010-0x001f] [ 0.439986] pnp 00:0a: [io 0x0022-0x003f] [ 0.439994] pnp 00:0a: [io 0x0044-0x005f] [ 0.440055] pnp 00:0a: [io 0x0063] [ 0.440063] pnp 00:0a: [io 0x0065] [ 0.440071] pnp 00:0a: [io 0x0067-0x006f] [ 0.440079] pnp 00:0a: [io 0x0072-0x007f] [ 0.440086] pnp 00:0a: [io 0x0080] [ 0.440094] pnp 00:0a: [io 0x0084-0x0086] [ 0.440102] pnp 00:0a: [io 0x0088] [ 0.440109] pnp 00:0a: [io 0x008c-0x008e] [ 0.440117] pnp 00:0a: [io 0x0090-0x009f] [ 0.440125] pnp 00:0a: [io 0x00a2-0x00bf] [ 0.440133] pnp 00:0a: [io 0x00e0-0x00ef] [ 0.440141] pnp 00:0a: [io 0x04d0-0x04d1] [ 0.440150] pnp 00:0a: [io 0x0000-0xffffffffffffffff disabled] [ 0.440160] pnp 00:0a: [io 0x0000-0xffffffffffffffff disabled] [ 0.440168] pnp 00:0a: [io 0x03f4] [ 0.440175] pnp 00:0a: [io 0x03f5] [ 0.440183] pnp 00:0a: [io 0x0374] [ 0.440190] pnp 00:0a: [io 0x0375] [ 0.440405] system 00:0a: [io 0x04d0-0x04d1] has been reserved [ 0.440432] system 00:0a: [io 0x03f4] has been reserved [ 0.440451] system 00:0a: [io 0x03f5] has been reserved [ 0.440469] system 00:0a: [io 0x0374] has been reserved [ 0.440488] system 00:0a: [io 0x0375] has been reserved [ 0.440508] system 00:0a: Plug and Play ACPI device, IDs PNP0c02 (active) [ 0.440550] pnp 00:0b: [io 0x00f0-0x00ff] [ 0.440572] pnp 00:0b: [irq 13] [ 0.440691] pnp 00:0b: Plug and Play ACPI device, IDs PNP0c04 (active) [ 0.440770] pnp 00:0c: [io 0x0810] [ 0.440779] pnp 00:0c: [io 0x0800-0x080f] [ 0.440787] pnp 00:0c: [io 0xffff] [ 0.440947] system 00:0c: [io 0x0810] has been reserved [ 0.440970] system 00:0c: [io 0x0800-0x080f] has been reserved [ 0.440989] system 00:0c: [io 0xffff] has been reserved [ 0.441010] system 00:0c: Plug and Play ACPI device, IDs PNP0c02 (active) [ 0.441620] pnp 00:0d: [io 0x0900-0x097f] [ 0.441630] pnp 00:0d: [io 0x09c0-0x09ff] [ 0.441639] pnp 00:0d: [io 0x0400-0x043f] [ 0.441647] pnp 00:0d: [io 0x0480-0x04bf] [ 0.441656] pnp 00:0d: [mem 0xfec00000-0xfec85fff] [ 0.441664] pnp 00:0d: [mem 0xfed1c000-0xfed1ffff] [ 0.441673] pnp 00:0d: [mem 0x000c0000-0x000dffff] [ 0.441689] pnp 00:0d: [mem 0x000e0000-0x000effff] [ 0.441697] pnp 00:0d: [mem 0x000f0000-0x000fffff] [ 0.441706] pnp 00:0d: [mem 0xff800000-0xffffffff] [ 0.441911] system 00:0d: [io 0x0900-0x097f] has been reserved [ 0.441935] system 00:0d: [io 0x09c0-0x09ff] has been reserved [ 0.441955] system 00:0d: [io 0x0400-0x043f] has been reserved [ 0.441975] system 00:0d: [io 0x0480-0x04bf] has been reserved [ 0.441997] system 00:0d: [mem 0xfec00000-0xfec85fff] could not be reserved [ 0.442019] system 00:0d: [mem 0xfed1c000-0xfed1ffff] has been reserved [ 0.442040] system 00:0d: [mem 0x000c0000-0x000dffff] could not be reserved [ 0.442061] system 00:0d: [mem 0x000e0000-0x000effff] could not be reserved [ 0.442082] system 00:0d: [mem 0x000f0000-0x000fffff] could not be reserved [ 0.442103] system 00:0d: [mem 0xff800000-0xffffffff] has been reserved [ 0.442126] system 00:0d: Plug and Play ACPI device, IDs PNP0c01 (active) [ 0.442308] pnp 00:0e: [mem 0xfed00000-0xfed003ff] [ 0.442454] pnp 00:0e: Plug and Play ACPI device, IDs PNP0103 (active) [ 0.442569] pnp 00:0f: [mem 0x7f6f0000-0x7f6fffff] [ 0.442762] system 00:0f: [mem 0x7f6f0000-0x7f6fffff] has been reserved [ 0.442788] system 00:0f: Plug and Play ACPI device, IDs PNP0c01 (active) [ 0.443360] pnp: PnP ACPI: found 16 devices [ 0.443378] ACPI: ACPI bus type pnp unregistered [ 0.443395] PnPBIOS: Disabled by ACPI PNP [ 0.486106] PCI: max bus depth: 3 pci_try_num: 4 [ 0.486189] pci 0000:00:1c.0: PCI bridge to [bus 01-01] [ 0.486217] pci 0000:00:1c.0: bridge window [io 0xe000-0xefff] [ 0.486241] pci 0000:00:1c.0: bridge window [mem 0xd0100000-0xd01fffff] [ 0.486266] pci 0000:00:1c.0: bridge window [mem 0xff700000-0xff7fffff pref] [ 0.486298] pci 0000:03:01.0: PCI bridge to [bus 04-04] [ 0.486319] pci 0000:03:01.0: bridge window [io 0xd000-0xdfff] [ 0.486348] pci 0000:03:01.0: bridge window [mem 0xd0000000-0xd00fffff] [ 0.486374] pci 0000:03:01.0: bridge window [mem 0xff600000-0xff6fffff 64bit pref] [ 0.486406] pci 0000:03:02.0: PCI bridge to [bus 05-05] [ 0.486444] pci 0000:03:03.0: PCI bridge to [bus 06-06] [ 0.486479] pci 0000:02:00.0: PCI bridge to [bus 03-06] [ 0.486499] pci 0000:02:00.0: bridge window [io 0xd000-0xdfff] [ 0.486522] pci 0000:02:00.0: bridge window [mem 0xd0000000-0xd00fffff] [ 0.486545] pci 0000:02:00.0: bridge window [mem 0xff600000-0xff6fffff 64bit pref] [ 0.486575] pci 0000:00:1c.1: PCI bridge to [bus 02-06] [ 0.486593] pci 0000:00:1c.1: bridge window [io 0xd000-0xdfff] [ 0.486615] pci 0000:00:1c.1: bridge window [mem 0xd0000000-0xd00fffff] [ 0.486637] pci 0000:00:1c.1: bridge window [mem 0xff600000-0xff6fffff pref] [ 0.486710] pci 0000:00:1c.0: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [ 0.486735] pci 0000:00:1c.0: setting latency timer to 64 [ 0.486774] pci 0000:00:1c.1: PCI INT B -> GSI 17 (level, low) -> IRQ 17 [ 0.486796] pci 0000:00:1c.1: setting latency timer to 64 [ 0.486817] pci 0000:02:00.0: setting latency timer to 64 [ 0.486836] pci 0000:03:01.0: setting latency timer to 64 [ 0.486858] pci 0000:03:02.0: setting latency timer to 64 [ 0.486880] pci 0000:03:03.0: setting latency timer to 64 [ 0.486893] pci_bus 0000:00: resource 4 [io 0x0000-0x0cf7] [ 0.486902] pci_bus 0000:00: resource 5 [io 0x0d00-0xffff] [ 0.486912] pci_bus 0000:00: resource 6 [mem 0x000a0000-0x000bffff] [ 0.486922] pci_bus 0000:00: resource 7 [mem 0x80000000-0xffffffff] [ 0.486932] pci_bus 0000:01: resource 0 [io 0xe000-0xefff] [ 0.486941] pci_bus 0000:01: resource 1 [mem 0xd0100000-0xd01fffff] [ 0.486951] pci_bus 0000:01: resource 2 [mem 0xff700000-0xff7fffff pref] [ 0.486961] pci_bus 0000:02: resource 0 [io 0xd000-0xdfff] [ 0.486970] pci_bus 0000:02: resource 1 [mem 0xd0000000-0xd00fffff] [ 0.486980] pci_bus 0000:02: resource 2 [mem 0xff600000-0xff6fffff pref] [ 0.486989] pci_bus 0000:03: resource 0 [io 0xd000-0xdfff] [ 0.486998] pci_bus 0000:03: resource 1 [mem 0xd0000000-0xd00fffff] [ 0.487008] pci_bus 0000:03: resource 2 [mem 0xff600000-0xff6fffff 64bit pref] [ 0.487018] pci_bus 0000:04: resource 0 [io 0xd000-0xdfff] [ 0.487028] pci_bus 0000:04: resource 1 [mem 0xd0000000-0xd00fffff] [ 0.487038] pci_bus 0000:04: resource 2 [mem 0xff600000-0xff6fffff 64bit pref] [ 0.487177] NET: Registered protocol family 2 [ 0.487405] IP route cache hash table entries: 32768 (order: 5, 131072 bytes) [ 0.488397] TCP established hash table entries: 131072 (order: 8, 1048576 bytes) [ 0.489792] TCP bind hash table entries: 65536 (order: 7, 524288 bytes) [ 0.490493] TCP: Hash tables configured (established 131072 bind 65536) [ 0.490525] TCP reno registered [ 0.490551] UDP hash table entries: 512 (order: 2, 16384 bytes) [ 0.490590] UDP-Lite hash table entries: 512 (order: 2, 16384 bytes) [ 0.490898] NET: Registered protocol family 1 [ 0.490970] pci 0000:00:02.0: Boot video device [ 0.491052] pci 0000:00:1d.0: PCI INT A -> GSI 20 (level, low) -> IRQ 20 [ 0.491092] pci 0000:00:1d.0: PCI INT A disabled [ 0.491134] pci 0000:00:1d.1: PCI INT B -> GSI 21 (level, low) -> IRQ 21 [ 0.491174] pci 0000:00:1d.1: PCI INT B disabled [ 0.491220] pci 0000:00:1d.2: PCI INT C -> GSI 22 (level, low) -> IRQ 22 [ 0.491259] pci 0000:00:1d.2: PCI INT C disabled [ 0.491307] pci 0000:00:1d.7: PCI INT D -> GSI 23 (level, low) -> IRQ 23 [ 0.864431] Freeing initrd memory: 13820k freed [ 2.088042] pci 0000:00:1d.7: EHCI: BIOS handoff failed (BIOS bug?) 01010001 [ 2.088207] pci 0000:00:1d.7: PCI INT D disabled [ 2.088267] PCI: CLS 64 bytes, default 64 [ 2.089248] audit: initializing netlink socket (disabled) [ 2.089287] type=2000 audit(1349363630.084:1): initialized [ 2.144783] highmem bounce pool size: 64 pages [ 2.144808] HugeTLB registered 2 MB page size, pre-allocated 0 pages [ 2.160057] VFS: Disk quotas dquot_6.5.2 [ 2.160232] Dquot-cache hash table entries: 1024 (order 0, 4096 bytes) [ 2.161716] fuse init (API version 7.17) [ 2.161995] msgmni has been set to 1713 [ 2.162925] Block layer SCSI generic (bsg) driver version 0.4 loaded (major 253) [ 2.163008] io scheduler noop registered [ 2.163023] io scheduler deadline registered [ 2.163048] io scheduler cfq registered (default) [ 2.163339] pcieport 0000:00:1c.0: setting latency timer to 64 [ 2.163530] pcieport 0000:00:1c.1: setting latency timer to 64 [ 2.163706] pcieport 0000:02:00.0: setting latency timer to 64 [ 2.163873] pcieport 0000:03:01.0: setting latency timer to 64 [ 2.163964] pcieport 0000:03:01.0: irq 40 for MSI/MSI-X [ 2.164193] pcieport 0000:03:02.0: setting latency timer to 64 [ 2.164272] pcieport 0000:03:02.0: irq 41 for MSI/MSI-X [ 2.164453] pcieport 0000:03:03.0: setting latency timer to 64 [ 2.164531] pcieport 0000:03:03.0: irq 42 for MSI/MSI-X [ 2.164783] pcieport 0000:00:1c.0: Signaling PME through PCIe PME interrupt [ 2.164801] pci 0000:01:00.0: Signaling PME through PCIe PME interrupt [ 2.164816] pcie_pme 0000:00:1c.0:pcie01: service driver pcie_pme loaded [ 2.164853] pcieport 0000:00:1c.1: Signaling PME through PCIe PME interrupt [ 2.164867] pcieport 0000:02:00.0: Signaling PME through PCIe PME interrupt [ 2.164880] pcieport 0000:03:01.0: Signaling PME through PCIe PME interrupt [ 2.164892] pci 0000:04:00.0: Signaling PME through PCIe PME interrupt [ 2.164904] pcieport 0000:03:02.0: Signaling PME through PCIe PME interrupt [ 2.164917] pcieport 0000:03:03.0: Signaling PME through PCIe PME interrupt [ 2.164932] pcie_pme 0000:00:1c.1:pcie01: service driver pcie_pme loaded [ 2.164988] pci_hotplug: PCI Hot Plug PCI Core version: 0.5 [ 2.165115] pciehp 0000:00:1c.0:pcie04: HPC vendor_id 8086 device_id 8110 ss_vid 8086 ss_did 8119 [ 2.165177] pciehp 0000:00:1c.0:pcie04: service driver pciehp loaded [ 2.165199] pciehp 0000:00:1c.1:pcie04: HPC vendor_id 8086 device_id 8112 ss_vid 8086 ss_did 8119 [ 2.165260] pciehp 0000:00:1c.1:pcie04: service driver pciehp loaded [ 2.165290] pciehp: PCI Express Hot Plug Controller Driver version: 0.4 [ 2.165488] intel_idle: MWAIT substates: 0x3020220 [ 2.165508] intel_idle: v0.4 model 0x1C [ 2.165513] intel_idle: lapic_timer_reliable_states 0x2 [ 2.165519] Marking TSC unstable due to TSC halts in idle states deeper than C2 [ 2.165779] input: Lid Switch as /devices/LNXSYSTM:00/device:00/PNP0C0D:00/input/input0 [ 2.165855] ACPI: Lid Switch [LID] [ 2.165983] input: Power Button as /devices/LNXSYSTM:00/device:00/PNP0C0C:00/input/input1 [ 2.166005] ACPI: Power Button [PWRB] [ 2.173811] thermal LNXTHERM:00: registered as thermal_zone0 [ 2.173829] ACPI: Thermal Zone [TZ00] (48 C) [ 2.174004] thermal LNXTHERM:01: registered as thermal_zone1 [ 2.174018] ACPI: Thermal Zone [TZ01] (34 C) [ 2.174194] thermal LNXTHERM:02: registered as thermal_zone2 [ 2.174207] ACPI: Thermal Zone [TZ02] (34 C) [ 2.174378] thermal LNXTHERM:03: registered as thermal_zone3 [ 2.174392] ACPI: Thermal Zone [TZ03] (34 C) [ 2.174503] ERST: Table is not found! [ 2.174513] GHES: HEST is not enabled! [ 2.174601] isapnp: Scanning for PnP cards... [ 2.176175] Serial: 8250/16550 driver, 32 ports, IRQ sharing enabled [ 2.196702] serial8250: ttyS0 at I/O 0x3f8 (irq = 4) is a 16550A [ 2.292409] serial8250: ttyS1 at I/O 0x2f8 (irq = 3) is a 16550A [ 2.528909] isapnp: No Plug & Play device found [ 2.588733] 00:05: ttyS0 at I/O 0x3f8 (irq = 4) is a 16550A [ 2.624523] 00:06: ttyS1 at I/O 0x2f8 (irq = 3) is a 16550A [ 2.640702] Linux agpgart interface v0.103 [ 2.645138] brd: module loaded [ 2.647452] loop: module loaded [ 2.648149] pata_acpi 0000:00:1f.1: setting latency timer to 64 [ 2.649238] Fixed MDIO Bus: probed [ 2.649315] tun: Universal TUN/TAP device driver, 1.6 [ 2.649327] tun: (C) 1999-2004 Max Krasnyansky <[email protected]> [ 2.649524] PPP generic driver version 2.4.2 [ 2.649824] ehci_hcd: USB 2.0 'Enhanced' Host Controller (EHCI) Driver [ 2.649884] ehci_hcd 0000:00:1d.7: PCI INT D -> GSI 23 (level, low) -> IRQ 23 [ 2.649937] ehci_hcd 0000:00:1d.7: setting latency timer to 64 [ 2.649946] ehci_hcd 0000:00:1d.7: EHCI Host Controller [ 2.650082] ehci_hcd 0000:00:1d.7: new USB bus registered, assigned bus number 1 [ 2.650148] ehci_hcd 0000:00:1d.7: debug port 1 [ 2.654045] ehci_hcd 0000:00:1d.7: cache line size of 64 is not supported [ 2.654093] ehci_hcd 0000:00:1d.7: irq 23, io mem 0xd02c4000 [ 2.668035] ehci_hcd 0000:00:1d.7: USB 2.0 started, EHCI 1.00 [ 2.668392] hub 1-0:1.0: USB hub found [ 2.668413] hub 1-0:1.0: 8 ports detected [ 2.668618] ohci_hcd: USB 1.1 'Open' Host Controller (OHCI) Driver [ 2.668666] uhci_hcd: USB Universal Host Controller Interface driver [ 2.668726] uhci_hcd 0000:00:1d.0: PCI INT A -> GSI 20 (level, low) -> IRQ 20 [ 2.668751] uhci_hcd 0000:00:1d.0: setting latency timer to 64 [ 2.668759] uhci_hcd 0000:00:1d.0: UHCI Host Controller [ 2.668910] uhci_hcd 0000:00:1d.0: new USB bus registered, assigned bus number 2 [ 2.668981] uhci_hcd 0000:00:1d.0: irq 20, io base 0x0000f040 [ 2.669335] hub 2-0:1.0: USB hub found [ 2.669355] hub 2-0:1.0: 2 ports detected [ 2.669508] uhci_hcd 0000:00:1d.1: PCI INT B -> GSI 21 (level, low) -> IRQ 21 [ 2.669531] uhci_hcd 0000:00:1d.1: setting latency timer to 64 [ 2.669538] uhci_hcd 0000:00:1d.1: UHCI Host Controller [ 2.669675] uhci_hcd 0000:00:1d.1: new USB bus registered, assigned bus number 3 [ 2.669739] uhci_hcd 0000:00:1d.1: irq 21, io base 0x0000f020 [ 2.670099] hub 3-0:1.0: USB hub found [ 2.670118] hub 3-0:1.0: 2 ports detected [ 2.670271] uhci_hcd 0000:00:1d.2: PCI INT C -> GSI 22 (level, low) -> IRQ 22 [ 2.670295] uhci_hcd 0000:00:1d.2: setting latency timer to 64 [ 2.670302] uhci_hcd 0000:00:1d.2: UHCI Host Controller [ 2.670435] uhci_hcd 0000:00:1d.2: new USB bus registered, assigned bus number 4 [ 2.670502] uhci_hcd 0000:00:1d.2: irq 22, io base 0x0000f000 [ 2.670869] hub 4-0:1.0: USB hub found [ 2.670888] hub 4-0:1.0: 2 ports detected [ 2.671186] usbcore: registered new interface driver libusual [ 2.671332] i8042: PNP: PS/2 Controller [PNP0303:PS2K,PNP0f03:PS2M] at 0x60,0x64 irq 1,12 [ 2.673408] serio: i8042 KBD port at 0x60,0x64 irq 1 [ 2.673437] serio: i8042 AUX port at 0x60,0x64 irq 12 [ 2.673844] mousedev: PS/2 mouse device common for all mice [ 2.674272] rtc_cmos 00:08: RTC can wake from S4 [ 2.674482] rtc_cmos 00:08: rtc core: registered rtc_cmos as rtc0 [ 2.674529] rtc0: alarms up to one year, y3k, 242 bytes nvram, hpet irqs [ 2.674691] device-mapper: uevent: version 1.0.3 [ 2.674903] device-mapper: ioctl: 4.22.0-ioctl (2011-10-19) initialised: [email protected] [ 2.675024] EISA: Probing bus 0 at eisa.0 [ 2.675037] EISA: Cannot allocate resource for mainboard [ 2.675050] Cannot allocate resource for EISA slot 1 [ 2.675061] Cannot allocate resource for EISA slot 2 [ 2.675072] Cannot allocate resource for EISA slot 3 [ 2.675083] Cannot allocate resource for EISA slot 4 [ 2.675094] Cannot allocate resource for EISA slot 5 [ 2.675105] Cannot allocate resource for EISA slot 6 [ 2.675116] Cannot allocate resource for EISA slot 7 [ 2.675127] Cannot allocate resource for EISA slot 8 [ 2.675137] EISA: Detected 0 cards. [ 2.675161] cpufreq-nforce2: No nForce2 chipset. [ 2.675401] cpuidle: using governor ladder [ 2.675786] cpuidle: using governor menu [ 2.675797] EFI Variables Facility v0.08 2004-May-17 [ 2.676429] TCP cubic registered [ 2.676751] NET: Registered protocol family 10 [ 2.678031] NET: Registered protocol family 17 [ 2.678052] Registering the dns_resolver key type [ 2.678107] Using IPI No-Shortcut mode [ 2.678515] PM: Hibernation image not present or could not be loaded. [ 2.678543] registered taskstats version 1 [ 2.701145] Magic number: 0:84:234 [ 2.701312] rtc_cmos 00:08: setting system clock to 2012-10-04 15:13:51 UTC (1349363631) [ 2.702280] BIOS EDD facility v0.16 2004-Jun-25, 0 devices found [ 2.702294] EDD information not available. [ 2.702858] Freeing unused kernel memory: 740k freed [ 2.703630] Write protecting the kernel text: 5816k [ 2.703692] Write protecting the kernel read-only data: 2376k [ 2.703706] NX-protecting the kernel data: 4424k [ 2.751226] udevd[84]: starting version 175 [ 2.980162] usb 1-1: new high-speed USB device number 2 using ehci_hcd [ 3.001394] r8169 Gigabit Ethernet driver 2.3LK-NAPI loaded [ 3.001474] r8169 0000:01:00.0: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [ 3.001554] r8169 0000:01:00.0: setting latency timer to 64 [ 3.001654] r8169 0000:01:00.0: irq 43 for MSI/MSI-X [ 3.004220] r8169 0000:01:00.0: eth0: RTL8168c/8111c at 0xf8416000, 00:18:92:03:10:46, XID 1c4000c0 IRQ 43 [ 3.004254] r8169 0000:01:00.0: eth0: jumbo features [frames: 6128 bytes, tx checksumming: ko] [ 3.004347] r8169 Gigabit Ethernet driver 2.3LK-NAPI loaded [ 3.005085] r8169 0000:04:00.0: PCI INT A -> GSI 18 (level, low) -> IRQ 18 [ 3.005182] r8169 0000:04:00.0: setting latency timer to 64 [ 3.005292] r8169 0000:04:00.0: irq 44 for MSI/MSI-X [ 3.007187] r8169 0000:04:00.0: eth1: RTL8168c/8111c at 0xf8418000, 00:18:92:03:10:47, XID 1c4000c0 IRQ 44 [ 3.007224] r8169 0000:04:00.0: eth1: jumbo features [frames: 6128 bytes, tx checksumming: ko] [ 3.034417] pata_sch 0000:00:1f.1: version 0.2 [ 3.034518] pata_sch 0000:00:1f.1: setting latency timer to 64 [ 3.036698] scsi0 : pata_sch [ 3.039842] scsi1 : pata_sch [ 3.040913] ata1: PATA max UDMA/100 cmd 0x1f0 ctl 0x3f6 bmdma 0xf060 irq 14 [ 3.040940] ata2: PATA max UDMA/100 cmd 0x170 ctl 0x376 bmdma 0xf068 irq 15 [ 3.131850] Initializing USB Mass Storage driver... [ 3.136405] scsi2 : usb-storage 1-1:1.0 [ 3.136642] usbcore: registered new interface driver usb-storage [ 3.136656] USB Mass Storage support registered. [ 3.524465] usb 3-1: new low-speed USB device number 2 using uhci_hcd [ 3.968144] usb 3-2: new full-speed USB device number 3 using uhci_hcd [ 4.137903] scsi 2:0:0:0: Direct-Access TS TS4GUFM-H 1100 PQ: 0 ANSI: 0 CCS [ 4.140067] sd 2:0:0:0: Attached scsi generic sg0 type 0 [ 4.140590] sd 2:0:0:0: [sda] 8028160 512-byte logical blocks: (4.11 GB/3.82 GiB) [ 4.141597] sd 2:0:0:0: [sda] Write Protect is off [ 4.141618] sd 2:0:0:0: [sda] Mode Sense: 43 00 00 00 [ 4.142974] sd 2:0:0:0: [sda] No Caching mode page present [ 4.143000] sd 2:0:0:0: [sda] Assuming drive cache: write through [ 4.145837] sd 2:0:0:0: [sda] No Caching mode page present [ 4.145858] sd 2:0:0:0: [sda] Assuming drive cache: write through [ 4.147931] sda: sda1 sda2 < sda5 > [ 4.150972] sd 2:0:0:0: [sda] No Caching mode page present [ 4.151001] sd 2:0:0:0: [sda] Assuming drive cache: write through [ 4.151023] sd 2:0:0:0: [sda] Attached SCSI disk [ 4.249168] input: HID 046a:004b as /devices/pci0000:00/0000:00:1d.1/usb3/3-1/3-1:1.0/input/input2 [ 4.249579] generic-usb 0003:046A:004B.0001: input,hidraw0: USB HID v1.11 Keyboard [HID 046a:004b] on usb-0000:00:1d.1-1/input0 [ 4.287805] input: HID 046a:004b as /devices/pci0000:00/0000:00:1d.1/usb3/3-1/3-1:1.1/input/input3 [ 4.289235] generic-usb 0003:046A:004B.0002: input,hidraw1: USB HID v1.11 Mouse [HID 046a:004b] on usb-0000:00:1d.1-1/input1 [ 4.297604] input: EloTouchSystems,Inc Elo TouchSystems 2216 AccuTouch\xffffffc2\xffffffae\xffffffae USB Touchmonitor Interface as /devices/pci0000:00/0000:00:1d.1/usb3/3-2/3-2:1.0/input/input4 [ 4.298913] generic-usb 0003:04E7:0050.0003: input,hidraw2: USB HID v1.00 Pointer [EloTouchSystems,Inc Elo TouchSystems 2216 AccuTouch\xffffffc2\xffffffae\xffffffae USB Touchmonitor Interface] on usb-0000:00:1d.1-2/input0 [ 4.299878] usbcore: registered new interface driver usbhid [ 4.299925] usbhid: USB HID core driver [ 4.352639] EXT4-fs (sda1): INFO: recovery required on readonly filesystem [ 4.352661] EXT4-fs (sda1): write access will be enabled during recovery [ 8.519257] EXT4-fs (sda1): recovery complete [ 8.564389] EXT4-fs (sda1): mounted filesystem with ordered data mode. Opts: (null) [ 14.280922] ADDRCONF(NETDEV_UP): eth0: link is not ready [ 14.280944] ADDRCONF(NETDEV_UP): eth1: link is not ready [ 14.310368] udevd[308]: starting version 175 [ 14.353873] Adding 1045500k swap on /dev/sda5. Priority:-1 extents:1 across:1045500k [ 14.428718] lp: driver loaded but no devices found [ 14.521667] EXT4-fs (sda1): re-mounted. Opts: errors=remount-ro [ 15.073459] [drm] Initialized drm 1.1.0 20060810 [ 15.097073] psb_gfx: module is from the staging directory, the quality is unknown, you have been warned. [ 15.180630] gma500 0000:00:02.0: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [ 15.180648] gma500 0000:00:02.0: setting latency timer to 64 [ 15.182117] Stolen memory information [ 15.182127] base in RAM: 0x7f800000 [ 15.182134] size: 7932K, calculated by (GTT RAM base) - (Stolen base), seems wrong [ 15.182143] the correct size should be: 8M(dvmt mode=3) [ 15.234889] Set up 1983 stolen pages starting at 0x7f800000, GTT offset 0K [ 15.235126] [drm] SGX core id = 0x01130000 [ 15.235135] [drm] SGX core rev major = 0x01, minor = 0x02 [ 15.235143] [drm] SGX core rev maintenance = 0x01, designer = 0x00 [ 15.268796] [Firmware Bug]: ACPI: No _BQC method, cannot determine initial brightness [ 15.269888] acpi device:04: registered as cooling_device2 [ 15.270568] acpi device:05: registered as cooling_device3 [ 15.270947] input: Video Bus as /devices/LNXSYSTM:00/device:00/PNP0A08:00/LNXVIDEO:00/input/input5 [ 15.271238] ACPI: Video Device [GFX0] (multi-head: yes rom: no post: no) [ 15.271424] [drm] Supports vblank timestamp caching Rev 1 (10.10.2010). [ 15.271434] [drm] No driver support for vblank timestamp query. [ 15.374694] type=1400 audit(1349363644.167:2): apparmor="STATUS" operation="profile_load" name="/sbin/dhclient" pid=435 comm="apparmor_parser" [ 15.385518] type=1400 audit(1349363644.179:3): apparmor="STATUS" operation="profile_load" name="/usr/lib/NetworkManager/nm-dhcp-client.action" pid=435 comm="apparmor_parser" [ 15.386369] type=1400 audit(1349363644.179:4): apparmor="STATUS" operation="profile_load" name="/usr/lib/connman/scripts/dhclient-script" pid=435 comm="apparmor_parser" [ 15.677514] r8169 0000:01:00.0: eth0: link down [ 15.694828] ADDRCONF(NETDEV_UP): eth0: link is not ready [ 16.537490] gma500 0000:00:02.0: allocated 800x480 fb [ 16.558066] fbcon: psbfb (fb0) is primary device [ 16.747122] gma500 0000:00:02.0: BL bug: Reg 00000000 save 00000000 [ 16.775550] Console: switching to colour frame buffer device 100x30 [ 16.781804] fb0: psbfb frame buffer device [ 16.781812] drm: registered panic notifier [ 16.870168] [drm] Initialized gma500 1.0.0 2011-06-06 for 0000:00:02.0 on minor 0 [ 16.871166] snd_hda_intel 0000:00:1b.0: power state changed by ACPI to D0 [ 16.871186] snd_hda_intel 0000:00:1b.0: power state changed by ACPI to D0 [ 16.871207] snd_hda_intel 0000:00:1b.0: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [ 16.871284] snd_hda_intel 0000:00:1b.0: setting latency timer to 64 [ 29.338953] r8169 0000:01:00.0: eth0: link up [ 29.339471] ADDRCONF(NETDEV_CHANGE): eth0: link becomes ready [ 31.427223] init: failsafe main process (675) killed by TERM signal [ 31.522411] type=1400 audit(1349363660.316:5): apparmor="STATUS" operation="profile_replace" name="/sbin/dhclient" pid=889 comm="apparmor_parser" [ 31.523956] type=1400 audit(1349363660.316:6): apparmor="STATUS" operation="profile_replace" name="/usr/lib/NetworkManager/nm-dhcp-client.action" pid=889 comm="apparmor_parser" [ 31.524882] type=1400 audit(1349363660.320:7): apparmor="STATUS" operation="profile_replace" name="/usr/lib/connman/scripts/dhclient-script" pid=889 comm="apparmor_parser" [ 31.525940] type=1400 audit(1349363660.320:8): apparmor="STATUS" operation="profile_load" name="/usr/sbin/tcpdump" pid=891 comm="apparmor_parser" [ 34.526445] postgres (1003): /proc/1003/oom_adj is deprecated, please use /proc/1003/oom_score_adj instead. [ 40.144048] eth0: no IPv6 routers present

    Read the article

  • Install gettext-0.17-1.el5.i386.rpm on CentOS 5.8 i386 gives "/usr/bin/python is needed" error

    - by viji
    I've removed yum by mistake. So, now I'm installing all the dependencies needed by yum manually. One of those is gettext-0.17-1.el5.i386.rpm and when I try to install it gives the following error, error: Failed dependencies: /usr/bin/python is needed by gettext-0.17-1.el5.i386 which is weird since I've installed python 2.6 already in the system. #python -V Python 2.6.8 #which python /usr/local/bin/python So I copied /usr/local/bin/python to /usr/bin/python and even after that I'm getting the same error. Any help is appreciated.

    Read the article

  • Linux missing disk space

    - by cpt.Buggy
    I have KVM vps with strange disk usage: # df -h Filesystem Size Used Avail Use% Mounted on /dev/sdb 493G 1.2G 466G 1% / tmpfs 4.0G 0 4.0G 0% /dev/shm /dev/sda1 96M 41M 51M 45% /boot # du -sh / du: cannot access `/proc/1633/task/1633/fd/4': No such file or directory du: cannot access `/proc/1633/task/1633/fdinfo/4': No such file or directory du: cannot access `/proc/1633/fd/4': No such file or directory du: cannot access `/proc/1633/fdinfo/4': No such file or directory 1021M / How could it be? Where are ~20G of free space?

    Read the article

  • Website load perfectly from localhost but after 3 or 4 hours is not load from remote computer until restart iis

    - by kia
    I have a web application on IIS 7.5 and windows server 2008 r2. It's load perfectly from localhost but after 3 or 4 hours is not load from remote computer until restart iis or recycle pool. Users of this site are about 900 people. Some setting of my pool: .Net frame work version: v2.0 Manage pipe line mode: Integrated Enable 32-Bit applications: true Identity: Administrator Idle time-out: 120 Load user profile: false Rapid fail protection enabled: false Disable recycling for configuration changes: true

    Read the article

  • what is best config for nginx worker_rlimit_nofile and worker_connections 28672

    - by Binh Nguyen
    i have issue of web-brower response ( especially on ie ) very slow, some time time out, and sometime hang out up to 20 seconds for one file redirect 301 when test with "f12 derverloper tool of ie" .. it report wait/start time very long. but after got connected the elements on web weill be dowload and show out fast ( test at xaluan.com ) It most happen when active user on web more than 2100 ( use google real time live analytic ). server running cenos 5 with ngix, apache, 32core cpu, 96G ram, raid 10 sas hdd.. == flowing is my config == user nobody; # no need for more workers in the proxy mode worker_processes 28; #old 32 #good at 24 error_log /var/log/nginx/error.log; #old add in end: info worker_rlimit_nofile 22528; events { worker_connections 22528; use epoll; # you should use epoll here for Linux kernels 2.6.x } http { server_name_in_redirect off; server_names_hash_max_size 10240; server_names_hash_bucket_size 1024; include mime.types; default_type application/octet-stream; server_tokens off; disable_symlinks off; sendfile on; tcp_nopush on; tcp_nodelay on; server_name_in_redirect off; server_names_hash_max_size 10240; server_names_hash_bucket_size 1024; include mime.types; default_type application/octet-stream; server_tokens off; disable_symlinks off; sendfile on; tcp_nopush on; tcp_nodelay on; keepalive_timeout 25; #old 5 gzip on; #old on gzip_vary on; gzip_disable "MSIE [1-6]\."; gzip_proxied any; gzip_http_version 1.1; gzip_min_length 1000; gzip_comp_level 6; gzip_buffers 16 8k; ignore_invalid_headers on; client_header_timeout 1m; #3m client_body_timeout 1m; #3m send_timeout 1m; #3m reset_timedout_connection on; connection_pool_size 256; client_header_buffer_size 256k; large_client_header_buffers 4 256k; client_max_body_size 100M; client_body_buffer_size 256k; request_pool_size 32k; output_buffers 4 32k; postpone_output 1460; proxy_temp_path /tmp/nginx_proxy/; client_body_in_file_only on; log_format bytes_log "$msec $bytes_sent ."; limit_conn_zone $binary_remote_addr zone=limit_per_ip:1m; limit_conn limit_per_ip 20; limit_req_zone $binary_remote_addr zone=allips:5m rate=200r/s; limit_req zone=allips burst=200 nodelay; include "/etc/nginx/vhosts/*"; } =========== I have play around with worker config 1- tried increase as some one suggess: worker_rlimit_nofile = worker_connections = worker_processes * 1024 = 32768 2- tried to set low: worker_processes = 28 and other worker at 22582 and other solution too .. but not work cause some time it make server load hight very quick 3- tried to comment out the # worker_rlimit_nofile . so it will be unlimited. it look like solved a bit about issue response time. but it also make server high load quick in peak time... Please help thanks PS: other apache you may have look for help me out thanks Listen 0.0.0.0:8081 User nobody Group nobody ExtendedStatus On ServerAdmin [email protected] ServerName server.xaluan.com LogLevel warn # These can be set in WHM under 'Apache Global Configuration' Timeout 100 TraceEnable Off ServerSignature Off ServerTokens ProductOnly FileETag None StartServers 15 <IfModule prefork.c> MinSpareServers 20 MaxSpareServers 50 #MaxSpareServers 40 </IfModule> ServerLimit 1572 MaxClients 1572 MaxRequestsPerChild 4000 # MaxRequestsPerChild 3000 KeepAlive On KeepAliveTimeout 3 MaxKeepAliveRequests 300 #MaxKeepAliveRequests 130

    Read the article

  • Flash Backed Write Cache (FBWC) without capacitor pack

    - by Martyn
    I brought a HP Smart Array P410 controller and it is installed and working fine in a HP Prolient Microserver with 4 drives in two RAID 1 arrays. I didn’t realise however that it came without any cache so would only work by directly writing straight to the disk, and the performance was horrible. So I then brought the 512MB Flash Backed Write Cache (FBWC) memory module as I was under the impression that with FBWC I would not need a battery. I got this idea from a forum post. "What do you guys think of the choice between 'BBWC' (battery backed write cache) and 'FBWC' (flash backed write cache)? The flashed based ones use non-volitile memory so need no battery." After installing the cache module however the server pretty much won’t boot. The P410 has a flashing amber light on it, and from the manual that doesn’t sound good. I’ve managed to get to the on board BIOS once and even managed to get to boot to the HP Array Configuration Utility (ACU) CD once, but every other time the Server continuingly reboots once it get to the POST screen and reads ARRAY INITILIZING %%%. The one time I reached the ACU, it reported a problem with the Cache Module. To me, it seems like the cache module is faulty, however the supplier tells me “Do you have an FBWC battery pack, p/n 587324-001, because that is required for the cache to work. If you have it, please complete an RMA form and we'll send a replacement / credit.” Does this sound right to you? I’ve been ordering the parts from the US and I don’t want to spend $77 + $40 p&p on a battery, wait a week for the shipping to find the card is faulty, and I don’t want to send back a working card?

    Read the article

  • Apache2 proxypass

    - by gatsby
    i'm trying to figure out why my apache2 reverse proxy doesn't work... hope someone can clarify. i'm using an apache server as a gateway with proxy pass: 10.184.1.2 is the IP. these are PP instructions i inserted in the 000-default config file. ProxyPass / http://192.168.102.31/ ProxyPassReverse / http://192.168.102.31/ the host 192.168.102.31 is an internal IP of a subnet wich is not reachable directly by clients, but only by the apache gateway. when i try to access such a address: http://apache_gateway_name/dir i see the client trying to reach 192.168.102.31 address and of course timeout occurs. can someone help? Best regards

    Read the article

  • nginx + php-fpm cycle redirection error on linode new vps

    - by chifliiiii
    I'm new to nginx, and I'm trying to make my first server run. I followed this guide as I'm trying to use it for a multisite wordpress site. After installing everything, I get a 500 Internal server error. If I check logs, I see this: 012/09/27 08:55:54 [error] 11565#0: *8 rewrite or internal redirection cycle while internally redirecting to "/index.html", client: xxx.xxx.xxx.xxx, server: localhost, request: "GET /favicon.ico HTTP/1.1", host: "www.mydomain.com" 2012/09/27 08:59:32 [error] 11618#0: *1 rewrite or internal redirection cycle while internally redirecting to "/index.html", client: xxx.xxx.xxx.xxx, server: localhost, request: "GET /phpmyadmin HTTP/1.1", host: "www.mydomain.com" My conf files are the following: nano /etc/nginx/sites-available/mydomain.com server { listen 80 default_server; server_name mydomain.com *.mydomain.com; root /srv/www/aciup.com/public; access_log /srv/www/mydomain.com/log/access.log; error_log /srv/www/mydomain.com/log/error.log; location / { index index.php; try_files $uri $uri/ /index.php?$args; } # Add trailing slash to */wp-admin requests. rewrite /wp-admin$ $scheme://$host$uri/ permanent; # Directives to send expires headers and turn off 404 error logging. location ~* \.(js|css|png|jpg|jpeg|gif|ico)$ { expires 24h; log_not_found off; } # this prevents hidden files (beginning with a period) from being served location ~ /\. { access_log off; log_not_found off; deny all; } # Pass uploaded files to wp-includes/ms-files.php. rewrite /files/$ /index.php last; if ($uri !~ wp-content/plugins) { rewrite /files/(.+)$ /wp-includes/ms-files.php?file=$1 last; } # Rewrite multisite '.../wp-.*' and '.../*.php'. if (!-e $request_filename) { rewrite ^/[_0-9a-zA-Z-]+(/wp-.*) $1 last; rewrite ^/[_0-9a-zA-Z-]+.*(/wp-admin/.*\.php)$ $1 last; rewrite ^/[_0-9a-zA-Z-]+(/.*\.php)$ $1 last; } location ~ \.php$ { client_max_body_size 25M; fastcgi_pass unix:/var/run/php5-fpm.sock; fastcgi_index index.php; include /etc/nginx/fastcgi_params; } } nano /etc/nginx/nginx.conf user www-data; worker_processes 4; worker_cpu_affinity 0001 0010 0100 1000; error_log /var/log/nginx/error.log; pid /var/run/nginx.pid; events { worker_connections 2048; } http { include /etc/nginx/mime.types; access_log /var/log/nginx/access.log; sendfile on; tcp_nopush on; keepalive_timeout 5; tcp_nodelay on; server_tokens off; gzip on; gzip_types text/plain text/css application/x-javascript text/xml application/xml application/xml+rss text/javascript; gzip_disable "MSIE [1-6]\.(?!.*SV1)"; include /etc/nginx/conf.d/*.conf; include /etc/nginx/sites-enabled/*; } Any help will be appreciated.

    Read the article

  • SUSE linux nginx and phpmyadmin 404 errors

    - by user968808
    I've installed nginx and phpmyadmin etc and most things work fine. I'm getting random problems though... e.g. when I click drop I get a message on the screen to say its updating and then the page does not refresh afterwards. Also randomly get 404 errors if I check all when trying to delete rows out of a database. Or if I import a file over around 10-20 rows i get 404 page not found. Where have I gone wrong?

    Read the article

  • How do I configure networking on CentOS 6 running on hyper-v?

    - by LonelyLonelyNetworkN00b
    I'm not using legacy adapters, and i've installed Linux Integration Components 3.2. THe problem i'm facing is that the command 'setup' or 'system-config-network' doesn't list any network interfaces. If i run ifconfig -a i can see both the network cards i've attached. By setting a ip using ifconfig i can get network connectivity. The problem is that it's not persistent after a reboot. I'm a 100% centos newbie, but I figure it has something to do with that the centos installer couldn't see the NICs on install. How can I fix this?

    Read the article

  • Is there anything like mail goggles for outlook?

    - by Eugene M
    Gmail has a cool feature that requires user interaction to send an email at certain hours of the day called mail goggles. Is there anything remotely like this for outlook? More specifically, what I'd like is some dialog that has a personal reminder (to make sure certain steps have been taken, like seeing who needs cc'd) and some sort of forced user interaction, like a checkbox. The tool would prevent you from sending he email until you had completed the interaction. If not, would it be possible to make something like this in VBA or as an addin? I realize this sounds like a really annoying feature, but I have a friend who is having a lot of trouble building certain email habits and this would be a sure-fire way to help.

    Read the article

  • Does lighter wallpaper consumes lesser power than a Darker one

    - by Lamb
    My VAIO advised me to switch to a White Background, to reduce power consumption. But it seems contradictory to common logic. Its like saying a brighter Torch consuming less than a dimmer one. Common Logic says that, Screen is BLACK when not using any POWER, so displaying black color should not consume any power (because without powering any pixel it gives black color) Also a white screen gives me more light than a darker one, so it should use more Energy. White Wallpaper = More Light Output = More Electrical Energy Consumed Black Wallpaper = Less Light = Less Electricity Consumed My question is - Is there anything wrong with the above argument ? A Lighter Wallpaper consumes less power than a Darker one. Is it true ? If yes, Why ?

    Read the article

  • Windows 7 task bar stuck in hiding, how to fix?

    - by Rainer Blome
    In Windows 7, I use the "Auto-hide the task bar" feature. Usually, it works fine: As soon as the pointer touches the screen bottom, the task bar pops up. However sometimes, it refuses to rise. Pressing the "Windows" key (or Ctrl-ESC) makes the start menu appear, forcing the task bar from hinding as well. Once I've done this, the task-bar auto-rises again. This is annoying, it interrupts flow. Has anyone else noticed this? How do I avoid this? Searching for "Windows 7 task bar auto-raise" shows that at least one other person experienced this problem: http://answers.microsoft.com/en-us/windows/forum/windows_7-desktop/how-can-i-fix-the-taskbars-auto-hide/8cdf6369-7354-4d29-9249-b7096ed0e28b?msgId=6dac3361-9d0f-4a9e-8642-b91a72826ba4 To answer the question posed by the "helpful" support engineer on the above page, of course I am running some apps when this happens, usually Explorer, Firefox, Eclipse, Cygwin/X, Xterm, Emacs, Notes, VPN client, Firewall. If my memory serves correctly, I have seen this behavior on earlier versions of Windows as well, XP at least. To reproduce this behavior, I tried switching between apps, and bringing apps to open other windows. I am unable to reproduce this behavior so far. So far, it appears to happen out of the blue, sometimes multiple times a day. Looks like a bug to me. The task bar should raise no matter what.

    Read the article

  • including files in a symlink directory when backing up with duplicity

    - by Rob
    I'm backing up using Duplicity, great tool. I'm unable to include files in the backup that are within a directory that is a symlink. Using the following: duplicity <dup args> --include /var/www/**/current --exclude '**' duplicity will only backup the symlink I've tried: duplicity <dup args> --include /var/www/**/current/* --exclude '**' # and duplicity <dup args> --include /var/www/**/current/** --exclude '**' Not even then symlink is backed up. the "current" directory links to directory like: /var/www/host.com/de9f2c7fd25e1b3afad3e85a0bd17d9b100db4b3 The files contains a few static html & css files. I want those files to be backed up, regardless of which sha'd directory "current" points to. Any help appreciated.

    Read the article

< Previous Page | 4 5 6 7 8 9 10 11 12 13 14 15  | Next Page >