Search Results

Search found 17 results on 1 pages for 'bladecenter'.

Page 1/1 | 1 

  • Bladecenter-E Power Module fault

    - by Lihnjo
    We have problem on IBM Bladecenter-E Critical Events Power module 2 is off. DC fault. Power module 4 is off. DC fault. Warnings and System Events Insufficient chassis power to support redundancy What is the best solution for this problem? Thanks AMM Service Data Help SPAPP Capture Available 10/13/2010 17:03:47 1090347 bytes Time: 11/19/2012 11:02:31 UUID: 42E1 5D2F D7BF 41A6 A4A2 48D1 3FB7 0540 MAC Address xx:xx:xx:xx:xx:xx MM Information Name: nnnnn Contact: aaa, bbb, ccc, England Location: [email protected] IP address: 111.222.333.444 Date Time Information GMT offset: +1:00 - Central Europe Time (Western Europe, Algeria, Nigeria, Angola) Adjust for DST: Yes NTP: Enabled NTP Hostname/IP: 111.222.333.444 System Health: Critical System Status Summary One or more monitored parameters are abnormal. Critical Events Power module 2 is off. DC fault. Power module 4 is off. DC fault. Warnings and System Events Insufficient chassis power to support redundancy CHASSIS (BladeCenter-E) in CHASSIS slot: 01 TopoPath is "CHASSIS[1]". Description : BladeCenter-E Width : 1 Sub Type : BladeCenter (BC) Power Mode : 220 v KVM Owner : CHASSIS[1]/BLADE[9] MT Owner : CHASSIS[1]/MGMT_MOD[1] Component Type : CHASSIS Inventory: VPD ID: 336 (decimal) POS ID EXT: 0 (decimal) POS ID: 8 (decimal) Machine Type/Model: 86773RG Machine Serial Number: 99ZL816 Part Number: 39R8561 FRU Number: 39R8563 FRU Serial Number: YK109174W1HV Manufacturer ID: IBM Hardware Revision: 3 (decimal) Manufacture Date: 18 (wk), 07 (yr) UUID: 42E1 5D2F D7BF 41A6 A4A2 48D1 3FB7 0540 (hex) Type Code: 97 (decimal) Sub-type Code: 0 (decimal) IANA Num: 336 (decimal) Product ID: 8 (decimal) Manufacturer Sub ID: FOXC Enviroment data: -------------- Type: : POWER_USAGE Unit: : WATTS Reading: : 0xa Sensor Label: : Midplane Sensor ID: : 0x0 MGMT MOD (Advanced Management Module) in MGMT_MOD slot: 01 TopoPath is "CHASSIS[1]/MGMT_MOD[1]". Description : Advanced Management Module Name : kant Width : 1 Component Role : Primary Component Type : MGMT MOD Insert Time : 28050132 Inventory: VPD ID: 288 (decimal) POS ID EXT: 0 (decimal) POS ID: 4 (decimal) Part Number: 39Y9659 FRU Number: 39Y9661 FRU Serial Number: YK11836CE2RC Manufacturer ID: IBM Hardware Revision: 4 (decimal) Manufacture Date: 50 (wk), 06 (yr) UUID: 1D95 9937 8CA5 11DB 9499 0014 5EDF 1C98 (hex) Type Code: 81 (decimal) Sub-type Code: 1 (decimal) IANA Num: 20301 (decimal) Product ID: 65 (decimal) Manufacturer Sub ID: ASUS Firmware data: Type : AMM firmware Build ID : BPET50P File Name : CNETCMUS.PKT Release Date : 03/26/2010 Release Level : 50 Revision - Major: 80 Port info: ======================================================== Topology Path ID : 1 Label : External Phy Orientation : EXTERNAL Port Number : 1 Type : MGT Physical Meidum : Copper Number of Link Intferfaces : 1 ------------------------------------ Link Ifc ID Number : 1 Link Ifc Transport Protocol : ENET Link Ifc Addr Type : MAC Link Ifc Burned-in Addr : xx:xx:xx:xx:xx:xx Link Ifc Admin Addr : 00:00:00:00:00:00 Link Ifc Addr in use : xx:xx:xx:xx:xx:xx ---------------------------------------------------------- Configuration behaviors: Save Only Enviroment data: -------------- Type: : TEMPERATURE Unit: : DEGREES_C Reading: : 38.00 Sensor Label: : MM Ambient Sensor ID: : 0x0 -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : +4.81 Sensor Label: : +5V Sensor ID: : 0x1b -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : +3.26 Sensor Label: : +3.3V Sensor ID: : 0x19 -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : +11.97 Sensor Label: : +12V Sensor ID: : 0x16 -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : -4.88 Sensor Label: : -5V Sensor ID: : 0x1e -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : +2.47 Sensor Label: : +2.5V Sensor ID: : 0x18 -------------- Type: : VOLTAGE Unit: : VOLTS Reading: : +1.76 Sensor Label: : +1.8V Sensor ID: : 0x15 -------------- Type: : POWER_USAGE Unit: : WATTS Reading: : 0x19 Sensor Label: : kant Sensor ID: : 0x0

    Read the article

  • IBM BladeCenter S: Disk Configuration

    - by gravyface
    Have just the one storage bay right now (SAS 15K 600GB x 6) and have configured one storage pool in RAID 10 with 4 disks (and two global spares). For each blade, I've created a volume and mapped accordingly: Blade #1 400 GB Blade #2 200 GB Blade #3 100 GB Blade #4 100 GB When I boot up Blade 1 and enter into the UEFI Setup (F1) followed by the Adapters and UEFI Drivers LSI Logic Fusion MPT SAS Driver Utility, I see 4 disks: two are the on-board 73GB drives, the other two are 200GB each and assume I'm being presented with two logical disks from the volume I created and mapped to this blade. I was a bit surprised by this: I figured I would've been presented with one logical drive per volume, not two. I'm assuming I can just configure whatever RAID level I wish that supports two disks, but not really sure what the benefits/trade-offs here. Should I go with RAID 10 on top of RAID 10? RAID 0? Software RAID 0/1/10? Does it even matter? If this is "normal" to see two disks, then I'm going to likely just do some benchmarking and see if it makes a difference changing the RAID levels (my guess is no); if this is not normal, well, please let me know. :)

    Read the article

  • Overview of the IBM BladeCenter

    IBM BladeCenter switches provide the small to mid size business with a number of tactical advantages. Companies can increase storage efficiency by permitting a sharing of disc storage across multiple... [Author: Bob Wall Jr. - Computers and Internet - April 10, 2010]

    Read the article

  • Which Linux distributions work on IBM's JS20 PowerPC blade?

    - by Matthew Rankin
    Which Linux distributions have people successfully gotten working on an IBM JS20 Blade, which has the PowerPC 970 processor? Specifically, I'm interested in distributions other than RHEL and SLES. What gotchas need to be watched out for when installing a particular distribution of Linux on the JS20? Non-Specific Distribution Information IBM's Linux on BladeCenter JS20 IBM's eServer BladeCenter JS20 Whitepaper — "The JS20 blade supports all popular Linux distributions including Red Hat®, Inc., and SUSE LINUX." PenguinPPC Distributions List PPCLinux — "This project is a repository of information on how to run GNU/Linux on PowerPC architectures." Ubuntu Specific Information Ubuntu PowerPC FAQ — "Ubuntu 6.10 was the last officially supported PowerPC version of Ubuntu." Ubuntu PowerPC Download Ubuntu 8.04 PowerPC Supported Hardware Ubuntu 9.10 Ports — Mac (PowerPC) and IBM-PPC (POWER5) server install CD. For Apple Macintosh G3, G4, and G5 computers, including iBooks and PowerBooks as well as IBM OpenPower machines. Debian Specific Information Debian on PowerPC —"We may have a 64bit port in the future." Looks like there is only a 32-bit version available currently. Debian on JS20 blades Installing Debian Etch on IBM JS20s Gentoo Specific Information Gentoo Linux Crux PPC Specific Information Crux PPC

    Read the article

  • Planning to buy a server with at least 48GB Ram, are the blades way to go?

    - by varchar1
    We're planning to host our website for the first time for ourselves. We have currently have a linode of 8 gigs and the memory is going up to 90% most of the time. So I want to move my website to my own server with huge RAM. So this will be first time to manage any physical hardware of a server. So I came across IBM's BladeCenter, found them interesting. So can I just buy the blade and run it? Or do I have to buy the chassis for sure? Also, do I need to buy an UPS? So how hard is it to setup? How about the hard drives? Can I setup them easily? Please advice.

    Read the article

  • Reset DRAC/MC password on Dell BladeCentre 1855

    - by Farseeker
    I have a Dell Blade Centre 1855, and nobody knows what the root password for the DRAC/MC card in the blade chassis is (I tried root/calvin). I do not have IP access to the DRAC/MC, nor do I have physical access to the back of the blade centre to access the DRAC/MC module. I do have serial access (and can see the login prompt in hyperterm). I do have physical access to the FRONT of the chassis (the back of the cabinet is locked and lo-and-behold the key cannot be found). Does anyone know how to reset the password? Every piece of literature I find on the internet tells me I need to log in, or run racadm on the host machine (which I can't, because it's inside a blade chassis). If someone does know how to do it with physical access to the back of the bladecentre, please post it anyway, as I'm sure I'll get access to the back of the cabinet one day)

    Read the article

  • Restart Fibre channel controller after blade bootup IBM HS bladecentre

    - by Spence
    I have a remote system that needs to resume on startup. If the system is simply powered on then the blades boot before the SAN is online and then the only thing you can do is restart the systems. Is it possible to restart the fibre channel controller? That way I could have a system restart the controller after boot, connect to the SAN and then restart all servers requiring SAN information? Please note that I'm not a sys admin, just shooting for ideas to get a clean startup to work, apologies if my terminology is wrong.

    Read the article

  • Communicating via Command Mode with IBM HS22 IMM via AMM

    - by MikeyB
    On previous model blades that contained a BMC, I was able to communicate from our external management station via pass-through commands to the BMC to do things such as power blades on/off, set VPD parameters, reboot the BMC, etc. Now on the HS22, a bunch of things happen differently. For example, we can no longer use the same pass-through commands to write VPD information pages and have them persist across reboots of the IMM - it looks as though those VPD pages are populated from information contained in the IMM. How do we use the Advanced Settings Utility from an external host to communicate with HS22 IMMs? Alternatively, what TCP Command Mode commands do we need to send to the AMM to communicate with the IMM? For our purposes, we specifically cannot communicate with the IMM from the blade itself. Specific example: When I send a pass-thru IPMI command via the AMM to the blade BMC to write information (such as MTM, Serial) into VPD page 0x10, it persists on blades with a BMC (HS21 for example). I can send the same IPMI command to write data to the VPD page on the HS22, however it does not persist across reboots of the IMM. What IPMI commands do I need to send to the IMM? What IPMI commands are asu sending when it sets the MTM & Serial?

    Read the article

  • IBM Bladecentre H Bootup

    - by Spence
    I have a bladecentre with blades, network and a SAN in a single rack. What I'd like to do is control the startup of the bladecentre so that when the rack is powered on that the blades will delay their bootup until the SAN is powered on correctly. Is this even possible? We have an AMM in the chassis if that helps. Basically we are looking into the reboot that occurs after power is restored to a UPS. I sincerely apologise for the noobness of this question, but I am a software guy trying to help :)

    Read the article

  • IBM Bladecentre H Bootup Sequence Control

    - by Spence
    I have a bladecentre with blades, network and a SAN in a single rack. What I'd like to do is control the startup of the bladecentre so that when the rack is powered on that the blades will delay their bootup until the SAN is powered on correctly. Is this even possible? We have an AMM in the chassis if that helps. Basically we are looking into the reboot that occurs after power is restored to a UPS. I sincerely apologise for the noobness of this question, but I am a software guy trying to help :)

    Read the article

  • Load balancing + NAT issue on BNT GBE 2-7 gear

    - by Clément Game
    Hi guys, I've got troubles configuring an Hardware load-Balancer with NAT functions. I have the following architecture: Internet === VIP (public) LB (private ip) ==== private addressed servers When a connection is initialised from the outside (internet) , the LB correctly forwards the SYN packet to one of the private servers. But when these servers want to reply with a SYN/ACK there is a problem. the initial SYN packet had as ip header : VIP = Private_server_Address But the private servers cannot reach VIP from their side (this is normal since it's nated), and then provide a correct reply. Have you guys any solution to correctly forward the packets to their correct destination ? Note: The load balancer, which is the default gw for the servers, also has a NAT rule for "masquerading" (actually more SNAT than real masquerading) Regards, Clément.

    Read the article

  • System X Marks the Spot

    Server Snapshot: IBM's innovation isn't limited to its POWER-based servers. A host of new System x and BladeCenter offerings are poised to bring Big Blue to the top volume spot.

    Read the article

  • System X Marks the Spot

    Server Snapshot: IBM's innovation isn't limited to its POWER-based servers. A host of new System x and BladeCenter offerings are poised to bring Big Blue to the top volume spot.

    Read the article

  • arcserve vs backup exec vray

    - by Luigi
    I have to buy one backup software to backup a vmware environment with the following server/applications: mixed microsoft windows 2003/2008/2012 server standard environment sql server 2005/2008 mixed linux centos/ubuntu servers postgresql sap environment exchange 2007 linux fileservers windows fileservers active directory random applications/sqlserver/fileserver on workstations xp/7/8 my hardware is: 5 blades on ibm bladecenter, various san, lto4 on 4gbit fiber channel connected to a windows2003 blade where I will install the backup software (backupexec or arcserve). What are your advice and comments over backupexec vray or arcserve choice ? I know that arcserve have a lower price. I used backup exec for some years but I found it pretty complicated. Thank you.

    Read the article

  • Bound external Cisco CIGESM ports to a specific BladeServer

    - by Vinícius Ferrão
    We have an IBM BladeCenter with 14 blade servers and one external Cisco CIGESM for Ethernet connectivity. Since this hardware is a little old, we will use it for other services, and we want to run a pfSense instance on one of the blades. It's just an Firewall Appliance, but it needs two network interfaces: one for the WAN and the other one for LAN access. Our architecture works on top of static routes, we don't use NAT, so we got the WAN IP in one interface routing to the another one. The main problem is how to plug the WAN cable in one of the four external ports and make it exclusive to the blade server containing the firewall. And we also need an exit port that goes through a 3COM 4200G switch that makes the internal routing and VLAN separation. Thanks in advance

    Read the article

  • MultiPath configuration on RHEL5 and Clariion CX-300

    - by Kamil Z
    I have problem with discovering my FC-connected CX-300 storage. Frankly speaking I'm complete novice in FibreChannel, so step by step explanation would be appreciated. My configuration consist of two IBM HS20 blades with RHEL5.4 on board and 2x Qlogic ISP2422-based 4Gb Fibre Channel HBAs on each blade. As a FC switch there are two Brocades built in BladeCenter Chassis, and finally there is EMC Clariion CX-300. CX300, and Brocade switches should be configured properly, because they were working fine with previous configuration, which main defference was RHEL3 instead RHEL5.4 Below there is my output from several usefull commands: #lspci | grep Fibre 06:01.0 FibreChannle: Qlogic Corp. ISP2422-based 4Gb Fibre Channel to PCI-X HBA (rev 02) 06:01.1 FibreChannle: Qlogic Corp. ISP2422-based 4Gb Fibre Channel to PCI-X HBA (rev 02) #lsmod | grep qla qla2xxx 1084741 0 scsi_transport_fc 37577 1 qla2xxx scsi_mod 141717 10 scsi_dh,qla2xxx,sg,scsi_transport_fc,usb_storage,libata,mptspi,mptscsih,scsi_transport_spi,sd_mod #cat /proc/scsi/scsi Attached Devices: Host: scsi0 Channel: 00 Id: 00 Lun: 00 Vendor: LSILOGIC Model: 1030 IM IM Rev: 1000 Type: Direct-Access ANSI SCSI revision: 02 Host: scsi0 Channel: 01 Id: 00 Lun: 00 Vendor: IBM-ESXS Model: ST936701LC FN Rev: B418 Type: Direct-Access ANSI SCSI revision: 04 Host: scsi0 Channel: 01 Id: 00 Lun: 00 Vendor: IBM-ESXS Model: ST936701LC FN Rev: B418 Type: Direct-Access ANSI SCSI revision: 04 I'd followed instructions from this site (editing /etc/multipath.conf), but i failed after multipath -ll - the output was empty. Do you have any suggestions about discovering FC Connected LUNs in such configuration?

    Read the article

  • Oracle Expands Sun Blade Portfolio for Cloud and Highly Virtualized Environments

    - by Ferhat Hatay
    Oracle announced the expansion of Sun Blade Portfolio for cloud and highly virtualized environments that deliver powerful performance and simplified management as tightly integrated systems.  Along with the SPARC T3-1B blade server, Oracle VM blade cluster reference configuration and Oracle's optimized solution for Oracle WebLogic Suite, Oracle introduced the dual-node Sun Blade X6275 M2 server module with some impressive benchmark results.   Benchmarks on the Sun Blade X6275 M2 server module demonstrate the outstanding performance characteristics critical for running varied commercial applications used in cloud and highly virtualized environments.  These include best-in-class SPEC CPU2006 results with the Intel Xeon processor 5600 series, six Fluent world records and 1.8 times the price-performance of the IBM Power 755 running NAMD, a prominent bio-informatics workload.   Benchmarks for Sun Blade X6275 M2 server module  SPEC CPU2006  The Sun Blade X6275 M2 server module demonstrated best in class SPECint_rate2006 results for all published results using the Intel Xeon processor 5600 series, with a result of 679.  This result is 97% better than the HP BL460c G7 blade, 80% better than the IBM HS22V blade, and 79% better than the Dell M710 blade.  This result demonstrates the density advantage of the new Oracle's server module for space-constrained data centers.     Sun Blade X6275M2 (2 Nodes, Intel Xeon X5670 2.93GHz) - 679 SPECint_rate2006; HP ProLiant BL460c G7 (2.93 GHz, Intel Xeon X5670) - 347 SPECint_rate2006; IBM BladeCenter HS22V (Intel Xeon X5680)  - 377 SPECint_rate2006; Dell PowerEdge M710 (Intel Xeon X5680, 3.33 GHz) - 380 SPECint_rate2006.  SPEC, SPECint, SPECfp reg tm of Standard Performance Evaluation Corporation. Results from www.spec.org as of 11/24/2010 and this report.    For more specifics about these results, please go to see http://blogs.sun.com/BestPerf   Fluent The Sun Fire X6275 M2 server module produced world-record results on each of the six standard cases in the current "FLUENT 12" benchmark test suite at 8-, 12-, 24-, 32-, 64- and 96-core configurations. These results beat the most recent QLogic score with IBM DX 360 M series platforms and QLogic "Truescale" interconnects.  Results on sedan_4m test case on the Sun Blade X6275 M2 server module are 23% better than the HP C7000 system, and 20% better than the IBM DX 360 M2; Dell has not posted a result for this test case.  Results can be found at the FLUENT website.   ANSYS's FLUENT software solves fluid flow problems, and is based on a numerical technique called computational fluid dynamics (CFD), which is used in the automotive, aerospace, and consumer products industries. The FLUENT 12 benchmark test suite consists of seven models that are well suited for multi-node clustered environments and representative of modern engineering CFD clusters. Vendors benchmark their systems with the principal objective of providing comparative performance information for FLUENT software that, among other things, depends on compilers, optimization, interconnect, and the performance characteristics of the hardware.   FLUENT application performance is representative of other commercial applications that require memory and CPU resources to be available in a scalable cluster-ready format.  FLUENT benchmark has six conventional test cases (eddy_417k, turbo_500k, aircraft_2m, sedan_4m, truck_14m, truck_poly_14m) at various core counts.   All information on the FLUENT website (http://www.fluent.com) is Copyrighted1995-2010 by ANSYS Inc. Results as of November 24, 2010. For more specifics about these results, please go to see http://blogs.sun.com/BestPerf   NAMD Results on the Sun Blade X6275 M2 server module running NAMD (a parallel molecular dynamics code designed for high-performance simulation of large biomolecular systems) show up to a 1.8X better price/performance than IBM's Power 7-based system.  For space-constrained environments, the ultra-dense Sun Blade X6275 M2 server module provides a 1.7X better price/performance per rack unit than IBM's system.     IBM Power 755 4-way Cluster (16U). Total price for cluster: $324,212. See IBM United States Hardware Announcement 110-008, dated February 9, 2010, pp. 4, 21 and 39-46.  Sun Blade X6275 M2 8-Blade Cluster (10U). Total price for cluster:  $193,939. Price/performance and performance/RU comparisons based on f1ATPase molecule test results. Sun Blade X6275 M2 cluster: $3,568/step/sec, 5.435 step/sec/RU. IBM Power 755 cluster: $6,355/step/sec, 3.189 step/sec/U. See http://www-03.ibm.com/systems/power/hardware/reports/system_perf.html. See http://www.ks.uiuc.edu/Research/namd/performance.html for more information, results as of 11/24/10.   For more specifics about these results, please go to see http://blogs.sun.com/BestPerf   Reverse Time Migration The Reverse Time Migration is heavily used in geophysical imaging and modeling for Oil & Gas Exploration.  The Sun Blade X6275 M2 server module showed up to a 40% performance improvement over the previous generation server module with super-linear scalability to 16 nodes for the 9-Point Stencil used in this Reverse Time Migration computational kernel.  The balanced combination of Oracle's Sun Storage 7410 system with the Sun Blade X6275 M2 server module cluster showed linear scalability for the total application throughput, including the I/O and MPI communication, to produce a final 3-D seismic depth imaged cube for interpretation. The final image write time from the Sun Blade X6275 M2 server module nodes to Oracle's Sun Storage 7410 system achieved 10GbE line speed of 1.25 GBytes/second or better performance. Between subsequent runs, the effects of I/O buffer caching on the Sun Blade X6275 M2 server module nodes and write optimized caching on the Sun Storage 7410 system gave up to 1.8 GBytes/second effective write performance. The performance results and characterization of this Reverse Time Migration benchmark could serve as a useful measure for many other I/O intensive commercial applications. 3D VTI Reverse Time Migration Seismic Depth Imaging, see http://blogs.sun.com/BestPerf/entry/3d_vti_reverse_time_migration for more information, results as of 11/14/2010.                            

    Read the article

1