Search Results

Search found 31954 results on 1279 pages for 'dependency object'.

Page 1065/1279 | < Previous Page | 1061 1062 1063 1064 1065 1066 1067 1068 1069 1070 1071 1072  | Next Page >

  • Loading not-so-well-formed XML into XDocument (multiple DTD)

    - by Gart
    I have got a problem handling data which is almost well-formed XHTML document except for it has multiple DTD declarations in the beginning: <!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Strict//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-strict.dtd"> <!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 3.2 Final//EN"> <!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 3.2 Final//EN"> <html xmlns="http://www.w3.org/1999/xhtml"> <head> ... </head> <body> ... </body> </html> I need load this data into XDocument object using only the first DTD and ignoring the rest declarations. It is not possible to completely ignore DTD processing because the document may have unusual characters like &acirc; or &euro; etc. The text is retrieved from external source and I have no idea why it comes like this. Obviously my naive attempt to load this document fails with System.Xml.XmlException : Cannot have multiple DTDs: var xmlReaderSettings = new XmlReaderSettings { DtdProcessing = DtdProcessing.Parse XmlResolver = new XmlPreloadedResolver(), ConformanceLevel = ConformanceLevel.Document, }; using (var xmlReader = XmlReader.Create(stream, xmlReaderSettings)) { return XDocument.Load(xmlReader); } What would be the best way to handle this kind of data?

    Read the article

  • SPException: Catastrophic failure (Exception from HRESULT: 0x8000FFF (E_UNEXPECTED) in Sharepoint

    - by BeraCim
    Hi all: I've been trying to programmatically copy custom content type and its custom columns from one web to another for some time now, and every time I get some sort of error or exception. After yet more tries, I received another strange and cryptic exception from Sharepoint after clicking onto a newly copied custom column in a custom content type. I checked the logs, and this is what I got: Failed to find the content type schema for ct-1033-0x1000blahblahblahcontenttypeId while caching feature data. Unknown SPRequest error occurred. More informationL 0x8000ffff Unable to locate the xml-definition for CType with SPContentTypeId '0x0100MorecontenttypeId', exception: Microsoft.SharePoint.SPException: Catastrophic failure(Exception from HRESULT: 0x8000FFFF (E_UNEXPECTED)) ---> System.Runtime.InteropServices.COMException (0x8000FFFF): Catastrophic failure... ... at Microsoft.SharePoint.Library.SPRequestInternalClass.GetGlobalContentTypeXml(String bstrUrl, Int32 type, UInt 32 lcid, Object varIdBytes... It failed to find quite a few content type schema. I'm confused with what Sharepoint is trying to do here, and why a simple process of copying a custom content type from one web to another just wouldn't work in contrast to the information found on the web e.g. this. Appreciate any help to get over this problem. Thanks.

    Read the article

  • VSTO Development - Key Improvements In VS2010 / .NET 4.0?

    - by dferraro
    Hi all, I am trying to make a case to my bosses on why we should use VS2010 for an upcoming Excel Workbook VSTO application. I haven't used VSTO before but have used VBA. With 2010 just around the corner, I wanted to read about the improvements made to see if it was worth using 2010 to develop this application. So far I have read 2 major improvements are ease of deployments and also debugging / com interop improvements ... I was just wondering if there was anything else I wasn't aware of, or if anyone here is actually developing in VSTO and has used 2010 and both 2008 and could help make a case / arm me with information. The main concern of my bosses is deploying .NET 4.0 runtime on the Citrix servers here... however it seems that with 3.5, we would have to deploy the VSTO runtime and PIA's, etc... So really wouldn't deployments be easier with 2010 because installing just the 4.0 runtime is better than having to install the 'VSTO Runtime' as well as PIA's, etc? Or is there something I'm missing here? Anyone here deploy VSTO app in an enterprise and can speak to this? Also - I'm trying to also fight to use C# over VB.NET for this app. Does anyone know any key reasons why (except for my bias on preference of syntax) it would be better to use C# over VB for this? Any key features lacking in VB VSTO development? I've read about the VSTO Power Tools, and one of them describes LINQ enalbment of the Excel Object Model classes - however it says 'a set of C# classes'... Does anyone know if they literally mean C# - so this would not work with VB.NET, or do they just mean the code is written in C#? Anyone ever used these power tools with VB? I am going to download & play with it now, but any help again is greatly appreciated Thanks very much for any information.

    Read the article

  • Swift Mailer email sending problem

    - by air
    i have downloaded Swift Mailer from their website and try to send simple email with following code <?php require_once 'lib/swift_required.php'; $transport = Swift_SmtpTransport::newInstance('smtp.example.org', 25) ->setUsername('your username') ->setPassword('your password') ; $mailer = Swift_Mailer::newInstance($transport); //Create a message $message = Swift_Message::newInstance('Wonderful Subject') ->setFrom(array('[email protected]' => 'John Doe')) ->setTo(array('[email protected]', '[email protected]' => 'A name')) ->setBody('Here is the message itself') ; //Send the message $result = $mailer->send($message); ? once i run the page it gives error Warning: fsockopen() [function.fsockopen]: php_network_getaddresses: getaddrinfo failed: No such host is known. in E:\web_sites\swift_mail\lib\classes\Swift\Transport\StreamBuffer.php on line 233 Warning: fsockopen() [function.fsockopen]: unable to connect to smtp.fiveocean.net:25 (php_network_getaddresses: getaddrinfo failed: No such host is known. ) in E:\web_sites\swift_mail\lib\classes\Swift\Transport\StreamBuffer.php on line 233 Fatal error: Uncaught exception 'Swift_TransportException' with message 'Connection could not be established with host smtp.fiveocean.net [php_network_getaddresses: getaddrinfo failed: No such host is known. #0]' in E:\web_sites\swift_mail\lib\classes\Swift\Transport\StreamBuffer.php:235 Stack trace: #0 E:\web_sites\swift_mail\lib\classes\Swift\Transport\StreamBuffer.php(70): Swift_Transport_StreamBuffer->_establishSocketConnection() #1 E:\web_sites\swift_mail\lib\classes\Swift\Transport\AbstractSmtpTransport.php(101): Swift_Transport_StreamBuffer->initialize(Array) #2 E:\web_sites\swift_mail\lib\classes\Swift\Mailer.php(74): Swift_Transport_AbstractSmtpTransport->start() #3 E:\web_sites\swift_mail\test.php(33): Swift_Mailer->send(Object(Swift_Message)) #4 {main} thrown in E:\web_sites\swift_mail\lib\classes\Swift\Transport\StreamBuffer.php on line 235 if i remove the line $result = $mailer->send($message); then page execute and no error message display, as soon as i add above line to send email, i got error. my outgoing server, port and user id & passwords are correct in my file. Thanks

    Read the article

  • JQuery BlockUI with UpdatePanel Viewstate Issue

    - by Chris
    I am using BlockUI to show a modal. Within the blocked modal I have an update panel. Within the update panel I have a textbox and a button that submits the content back to the server. Everything works fine up to this point (the blockUI is called, the modal appears, and the button performs the postback). However, when the button's click event is fired the value for the textbox is consistently empty even if text was entered. When the update panel updates the textbox shows up blank. It appears that this may be some sort of viewstate issue and I haven't turned off viewstate. <a href="javascript:$.blockUI({ message: $('#divTest') });">SHOW MODAL</a> <div id="divTest" style="display: none;"> <asp:UpdatePanel ID="upTest" UpdateMode="Conditional" runat="server"> <ContentTemplate> <asp:TextBox ID="txtTestVS" runat="server" /><br /> <asp:Button ID="cmdTest" Text="TEST" OnClick="cmdTest_Click" UseSubmitBehavior="false" runat="server" /> </ContentTemplate> </asp:UpdatePanel> SERVER-SIDE: protected void cmdTest_Click(object sender, EventArgs e) { string x = txtTestVS.Text; } String "x" always equal "".

    Read the article

  • How to achieve "Blendability" when using DataServiceCollection in my ViewModel

    - by andlju
    I'm looking at using oData endpoints in my Silverlight client. Naturally, I'm doing MVVM and I want the project to be nice and "Blendable" (i.e. I must be able to cleanly use static data instead of the oData endpoints when in design mode.) Now to the problem. I'd like to use the DataServiceCollection in my ViewModels, since it allows for nice bindable collections without having to worry too much with BeginExecute/EndExecute etc. Now, let's look at some code. My Model interface looks like this: public interface ITasksModel { IQueryable<Task> Tasks { get; } } The oData endpoint implementation of that interface: public class TasksModel : ITasksModel { Uri svcUri = new Uri("http://localhost:2404/Services/TasksDataService.svc"); TaskModelContainer _container; public TasksModel() { _container = new TaskModelContainer(svcUri); } public IQueryable<Task> Tasks { get { return _container.TaskSet; } } } And the "Blendable" design-time implementation: public class DesignModeTasksModel : ITasksModel { private List<Task> _taskCollection = new List<Task>(); public DesignModeTasksModel() { _taskCollection.Add(new Task() { Id = 1, Title = "Task 1" }); _taskCollection.Add(new Task() { Id = 2, Title = "Task 2" }); _taskCollection.Add(new Task() { Id = 3, Title = "Task 3" }); } public IQueryable<Task> Tasks { get { return _taskCollection.AsQueryable(); } } } However, when I try to use this last one in my ViewModel constructor: public TaskListViewModel(ITasksModel tasksModel) { _tasksModel = tasksModel; _tasks = new DataServiceCollection<Task>(); _tasks.LoadAsync(_tasksModel.Tasks); } I get an exception: Only a typed DataServiceQuery object can be supplied when calling the LoadAsync method on DataServiceCollection. First of all, if this is the case, why not make the input parameter of LoadAsync be typed as DataServiceQuery? Second, what is the "proper" way of doing what I'm trying to accomplish?

    Read the article

  • "Message":"Invalid JSON primitive: RecordId."

    - by Radhi
    getting error in ajax call from jquery. here is my jquery function function AddAlbumToMyProfile(AlbumId, AlbumName, AlbumTypeName) { var obj = { AlbumId: AlbumId, AlbumName: AlbumName, AlbumTypeName: AlbumTypeName }; //following is ASP.NET AJAX serialize function to convert //object into jSON. var json = Sys.Serialization.JavaScriptSerializer.serialize(obj); $.ajax({ type: "POST", url: "Gallary.aspx/AddAlbumToMyProfile", data: json, contentType: "application/json; charset=utf-8", dataType: "json", async: true, cache: false, success: function(msg) { if (msg.d == '') { alert("Album Added to your profile"); } else { alert(msg.d); } }, error: function(XMLHttpRequest, textStatus, errorThrown) { } }); } and this is my webmethod [WebMethod] public static string DeleteRecord(Int64 RecordId, Int64 UserId, Int64 UserProfileId, string ItemType, string FileName) { try { string FilePath = HttpContext.Current.Server.MapPath(FileName); XDocument xmldoc = XDocument.Load(FilePath); XElement Xelm = xmldoc.Element("UserProfile"); XElement parentElement = Xelm.XPathSelectElement(ItemType + "/Fields"); (from BO in parentElement.Descendants("Record") where BO.Element("Id").Attribute("value").Value == RecordId.ToString() select BO).Remove(); XDocument xdoc = XDocument.Parse(Xelm.ToString(), LoadOptions.PreserveWhitespace); xdoc.Save(FilePath); UserInfoHandler obj = new UserInfoHandler(); return obj.GetHTML(UserId, UserProfileId, FileName, ItemType, RecordId, Xelm).ToString(); } catch (Exception ex) { HandleException.LogError(ex, "EditUserProfile.aspx", "DeleteRecord"); } return "success"; } can anybody please tell me whats wrong in my code?? i am getting error: {"Message":"Invalid JSON primitive: RecordId.","StackTrace":" at System.Web.Script.Serialization.JavaScriptObjectDeserializer.DeserializePrimitiveObject()\r\n at System.Web.Script.Serialization.JavaScriptObjectDeserializer.DeserializeInternal(Int32 depth)\r\n at System.Web.Script.Serialization.JavaScriptObjectDeserializer.BasicDeserialize(String input, Int32 depthLimit, JavaScriptSerializer serializer)\r\n at System.Web.Script.Serialization.JavaScriptSerializer.Deserialize(JavaScriptSerializer serializer, String input, Type type, Int32 depthLimit)\r\n at System.Web.Script.Serialization.JavaScriptSerializer.Deserialize[T](String input)\r\n at System.Web.Script.Services.RestHandler.GetRawParamsFromPostRequest(HttpContext context, JavaScriptSerializer serializer)\r\n at System.Web.Script.Services.RestHandler.GetRawParams(WebServiceMethodData methodData, HttpContext context)\r\n at System.Web.Script.Services.RestHandler.ExecuteWebServiceCall(HttpContext context, WebServiceMethodData methodData)","ExceptionType":"System.ArgumentException"}

    Read the article

  • Understanding ServiceKnownType in WCF

    - by SLC
    I am having a little trouble understanding ServiceKnownType in WCF. Taken from this blog, the following code does not work: [DataContract(Namespace = “http://mycompany.com/”)] public class Shape{…} [DataContract(Namespace = “http://mycompany.com/”)] public class Circle : Shape {…} [ServiceContract] public interface IMyServer { [OperationContract] bool AddShape(Shape shape); } . IMyServer client = new ChannelFactory<IMyServer>(binding, endPoint).CreateChannel(); client.AddShape(new Circle()); The reason it doesn't work is because you are trying to add a circle, but the servicecontract only allows a Shape. You are supposed to do something with knowntypes, but I am a bit confused about how that works. Since that code is in the service, why doesn't it know automatically that a Circle is derived from Shape? Additionally, what does ServiceKnownType actually do? When ServiceKnownType is put below the DataContract, apparently that makes it work. I am guessing it says hey, this particular object type called Shape can also be a Circle. I am having trouble understanding why it would do it this way around, because if you add a new type like Square you are going to have to add that too, wouldn't it make sense if it cannot infer it, to put the KnownType onto the Square rather than the Shape? So the Square says hey, I am a Shape, and you don't have to fiddle with the Shape class?

    Read the article

  • ORA-03113 in code. In addition, TNS-12535 and ORA-03137 in alert file

    - by user1348107
    I've got an exception that contain ORA-03113: (SiPPSS.GetPrintWorkDirectDetail) - ERR:ORA-03113: end-of-file on communication channel Process ID: 7448 Session ID: 30 Serial number: 9802 ?????:12110937 ????:T855 Oracle.DataAccess.Client.OracleException ORA-03113: end-of-file on communication channel Process ID: 7448 Session ID: 30 Serial number: 9802 ?? Oracle.DataAccess.Client.OracleException.HandleErrorHelper(Int32 errCode, OracleConnection conn, IntPtr opsErrCtx, OpoSqlValCtx* pOpoSqlValCtx, Object src, String procedure, Boolean bCheck) ?? Oracle.DataAccess.Client.OracleException.HandleError(Int32 errCode, OracleConnection conn, String procedure, IntPtr opsErrCtx, OpoSqlValCtx* pOpoSqlValCtx, Object src, Boolean bCheck) ?? Oracle.DataAccess.Client.OracleCommand.ExecuteReader(Boolean requery, Boolean fillRequest, CommandBehavior behavior) ?? Oracle.DataAccess.Client.OracleDataAdapter.Fill(DataTable[] dataTables, Int32 startRecord, Int32 maxRecords, IDbCommand command, CommandBehavior behavior) ?? System.Data.Common.DbDataAdapter.Fill(DataTable dataTable) ?? SiPPSS.VSireiMeisaiDsTableAdapters.V_SIREI_MEISAITableAdapter.FillByRunningNoAndProcNo(V_SIREI_MEISAIDataTable dataTable, String RUNNING_NO, String PROC_NO) ?? C:\SVM\trunk\SiPPSSServer\Server\Dao\View\VSireiMeisaiDs.Designer.vb:? 386 ?? SiPPSS.GetPrintWorkDirectDetail.Execute(BLogicParam param) ?? C:\SVM\trunk\SiPPSSServer\Server\BLogic\Screen\Printing\Rprt0701\GetPrintWorkDirectDetail.vb:? 105 In this case, the oracle alert log as beblow: Fatal NI connect error 12170. VERSION INFORMATION: TNS for 64-bit Windows: Version 11.2.0.1.0 - Production Oracle Bequeath NT Protocol Adapter for 64-bit Windows: Version 11.2.0.1.0 - Production Windows NT TCP/IP NT Protocol Adapter for 64-bit Windows: Version 11.2.0.1.0 - Production Time: 01-11?-2012 13:50:45 Tracing not turned on. Tns error struct: ns main err code: 12535 TNS-12535: TNS: ??????·???????? ns secondary err code: 12560 nt main err code: 505 TNS-00505: ??????????? nt secondary err code: 60 nt OS err code: 0 Client address: (ADDRESS=(PROTOCOL=tcp)(HOST=10.41.102.53)(PORT=1794)) Thu Nov 01 13:54:17 2012 Thread 1 cannot allocate new log, sequence 1880 Private strand flush not complete Current log# 1 seq# 1879 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thread 1 advanced to log sequence 1880 (LGWR switch) Current log# 2 seq# 1880 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Thu Nov 01 13:54:21 2012 Archived Log entry 1118 added for thread 1 sequence 1879 ID 0xe48db805 dest 1: Thu Nov 01 14:40:12 2012 Thread 1 cannot allocate new log, sequence 1881 Private strand flush not complete Current log# 2 seq# 1880 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Thread 1 advanced to log sequence 1881 (LGWR switch) Current log# 3 seq# 1881 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Thu Nov 01 14:40:16 2012 Archived Log entry 1119 added for thread 1 sequence 1880 ID 0xe48db805 dest 1: Thu Nov 01 15:27:42 2012 Thread 1 cannot allocate new log, sequence 1882 Private strand flush not complete Current log# 3 seq# 1881 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Thread 1 advanced to log sequence 1882 (LGWR switch) Current log# 1 seq# 1882 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thu Nov 01 15:27:46 2012 Archived Log entry 1120 added for thread 1 sequence 1881 ID 0xe48db805 dest 1: Thu Nov 01 16:23:48 2012 Thread 1 cannot allocate new log, sequence 1883 Private strand flush not complete Current log# 1 seq# 1882 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thread 1 advanced to log sequence 1883 (LGWR switch) Current log# 2 seq# 1883 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Thu Nov 01 16:23:52 2012 Archived Log entry 1121 added for thread 1 sequence 1882 ID 0xe48db805 dest 1: Thu Nov 01 17:05:50 2012 Thread 1 cannot allocate new log, sequence 1884 Private strand flush not complete Current log# 2 seq# 1883 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Thread 1 advanced to log sequence 1884 (LGWR switch) Current log# 3 seq# 1884 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Thu Nov 01 17:05:55 2012 Archived Log entry 1122 added for thread 1 sequence 1883 ID 0xe48db805 dest 1: Thu Nov 01 17:26:52 2012 Fatal NI connect error 12170. VERSION INFORMATION: TNS for 64-bit Windows: Version 11.2.0.1.0 - Production Oracle Bequeath NT Protocol Adapter for 64-bit Windows: Version 11.2.0.1.0 - Production Windows NT TCP/IP NT Protocol Adapter for 64-bit Windows: Version 11.2.0.1.0 - Production Time: 01-11?-2012 17:26:52 Tracing not turned on. Tns error struct: ns main err code: 12535 TNS-12535: TNS: ??????·???????? ns secondary err code: 12560 nt main err code: 505 TNS-00505: ??????????? nt secondary err code: 60 nt OS err code: 0 Client address: (ADDRESS=(PROTOCOL=tcp)(HOST=10.41.102.62)(PORT=1286)) Thu Nov 01 17:27:16 2012 Fatal NI connect error 12170. VERSION INFORMATION: TNS for 64-bit Windows: Version 11.2.0.1.0 - Production Oracle Bequeath NT Protocol Adapter for 64-bit Windows: Version 11.2.0.1.0 - Production Windows NT TCP/IP NT Protocol Adapter for 64-bit Windows: Version 11.2.0.1.0 - Production Time: 01-11?-2012 17:27:16 Tracing not turned on. Tns error struct: ns main err code: 12535 TNS-12535: TNS: ??????·???????? ns secondary err code: 12560 nt main err code: 505 TNS-00505: ??????????? nt secondary err code: 60 nt OS err code: 0 Client address: (ADDRESS=(PROTOCOL=tcp)(HOST=10.41.102.62)(PORT=1285)) Thu Nov 01 18:08:39 2012 Thread 1 advanced to log sequence 1885 (LGWR switch) Current log# 1 seq# 1885 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thu Nov 01 18:08:40 2012 Archived Log entry 1123 added for thread 1 sequence 1884 ID 0xe48db805 dest 1: Thu Nov 01 19:33:21 2012 Thread 1 cannot allocate new log, sequence 1886 Private strand flush not complete Current log# 1 seq# 1885 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thread 1 advanced to log sequence 1886 (LGWR switch) Current log# 2 seq# 1886 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Thu Nov 01 19:33:25 2012 Archived Log entry 1124 added for thread 1 sequence 1885 ID 0xe48db805 dest 1: Thu Nov 01 20:32:25 2012 Thread 1 cannot allocate new log, sequence 1887 Private strand flush not complete Current log# 2 seq# 1886 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Thread 1 advanced to log sequence 1887 (LGWR switch) Current log# 3 seq# 1887 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Thu Nov 01 20:32:29 2012 Archived Log entry 1125 added for thread 1 sequence 1886 ID 0xe48db805 dest 1: Thu Nov 01 21:13:07 2012 Thread 1 advanced to log sequence 1888 (LGWR switch) Current log# 1 seq# 1888 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thu Nov 01 21:13:08 2012 Archived Log entry 1126 added for thread 1 sequence 1887 ID 0xe48db805 dest 1: Thu Nov 01 22:00:00 2012 Setting Resource Manager plan SCHEDULER[0x3006]:DEFAULT_MAINTENANCE_PLAN via scheduler window Setting Resource Manager plan DEFAULT_MAINTENANCE_PLAN via parameter Thu Nov 01 22:00:00 2012 Starting background process VKRM Thu Nov 01 22:00:00 2012 VKRM started with pid=32, OS id=4048 Thu Nov 01 22:00:59 2012 Thread 1 cannot allocate new log, sequence 1889 Private strand flush not complete Current log# 1 seq# 1888 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thread 1 advanced to log sequence 1889 (LGWR switch) Current log# 2 seq# 1889 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Thu Nov 01 22:01:03 2012 Archived Log entry 1127 added for thread 1 sequence 1888 ID 0xe48db805 dest 1: Thu Nov 01 22:32:36 2012 Thread 1 advanced to log sequence 1890 (LGWR switch) Current log# 3 seq# 1890 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Thu Nov 01 22:32:37 2012 Archived Log entry 1128 added for thread 1 sequence 1889 ID 0xe48db805 dest 1: Thu Nov 01 22:33:18 2012 Errors in file d:\oracle\diag\rdbms\siporex\siporex\trace\siporex_ora_11884.trc (incident=101313): ORA-03137: TTC protocol internal error : [12333] [8] [49] [50] [] [] [] [] Incident details in: d:\oracle\diag\rdbms\siporex\siporex\incident\incdir_101313\siporex_ora_11884_i101313.trc Thu Nov 01 22:33:21 2012 Trace dumping is performing id=[cdmp_20121101223321] Thu Nov 01 22:40:43 2012 Thread 1 cannot allocate new log, sequence 1891 Private strand flush not complete Current log# 3 seq# 1890 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Thread 1 advanced to log sequence 1891 (LGWR switch) Current log# 1 seq# 1891 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thu Nov 01 22:40:47 2012 Archived Log entry 1129 added for thread 1 sequence 1890 ID 0xe48db805 dest 1: Thu Nov 01 23:47:30 2012 Thread 1 cannot allocate new log, sequence 1892 Private strand flush not complete Current log# 1 seq# 1891 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thread 1 advanced to log sequence 1892 (LGWR switch) Current log# 2 seq# 1892 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Thu Nov 01 23:47:34 2012 Archived Log entry 1130 added for thread 1 sequence 1891 ID 0xe48db805 dest 1: Fri Nov 02 00:49:31 2012 Thread 1 cannot allocate new log, sequence 1893 Private strand flush not complete Current log# 2 seq# 1892 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Thread 1 advanced to log sequence 1893 (LGWR switch) Current log# 3 seq# 1893 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Fri Nov 02 00:49:35 2012 Archived Log entry 1131 added for thread 1 sequence 1892 ID 0xe48db805 dest 1: Fri Nov 02 01:43:12 2012 Thread 1 cannot allocate new log, sequence 1894 Private strand flush not complete Current log# 3 seq# 1893 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Thread 1 advanced to log sequence 1894 (LGWR switch) Current log# 1 seq# 1894 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Fri Nov 02 01:43:17 2012 Archived Log entry 1132 added for thread 1 sequence 1893 ID 0xe48db805 dest 1: Fri Nov 02 01:52:51 2012 Errors in file d:\oracle\diag\rdbms\siporex\siporex\trace\siporex_ora_6124.trc (incident=101273): ORA-03137: TTC protocol internal error : [12333] [4] [80] [82] [] [] [] [] Incident details in: d:\oracle\diag\rdbms\siporex\siporex\incident\incdir_101273\siporex_ora_6124_i101273.trc Fri Nov 02 01:52:54 2012 Trace dumping is performing id=[cdmp_20121102015254] Fri Nov 02 02:00:00 2012 Clearing Resource Manager plan via parameter Fri Nov 02 02:43:37 2012 Thread 1 cannot allocate new log, sequence 1895 Private strand flush not complete Current log# 1 seq# 1894 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thread 1 advanced to log sequence 1895 (LGWR switch) Current log# 2 seq# 1895 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Fri Nov 02 02:43:41 2012 Archived Log entry 1133 added for thread 1 sequence 1894 ID 0xe48db805 dest 1: Fri Nov 02 04:46:18 2012 Thread 1 cannot allocate new log, sequence 1896 Private strand flush not complete Current log# 2 seq# 1895 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Thread 1 advanced to log sequence 1896 (LGWR switch) Current log# 3 seq# 1896 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Fri Nov 02 04:46:22 2012 Archived Log entry 1134 added for thread 1 sequence 1895 ID 0xe48db805 dest 1: Fri Nov 02 04:51:41 2012 Errors in file d:\oracle\diag\rdbms\siporex\siporex\trace\siporex_ora_4048.trc (incident=101425): ORA-03137: TTC protocol internal error : [12333] [4] [67] [85] [] [] [] [] Incident details in: d:\oracle\diag\rdbms\siporex\siporex\incident\incdir_101425\siporex_ora_4048_i101425.trc Fri Nov 02 04:51:44 2012 Trace dumping is performing id=[cdmp_20121102045144] Fri Nov 02 05:54:44 2012 Thread 1 cannot allocate new log, sequence 1897 Private strand flush not complete Current log# 3 seq# 1896 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Thread 1 advanced to log sequence 1897 (LGWR switch) Current log# 1 seq# 1897 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Fri Nov 02 05:54:48 2012 Archived Log entry 1135 added for thread 1 sequence 1896 ID 0xe48db805 dest 1: Fri Nov 02 07:00:34 2012 Thread 1 cannot allocate new log, sequence 1898 Private strand flush not complete Current log# 1 seq# 1897 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thread 1 advanced to log sequence 1898 (LGWR switch) Current log# 2 seq# 1898 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Fri Nov 02 07:00:38 2012 Archived Log entry 1136 added for thread 1 sequence 1897 ID 0xe48db805 dest 1: Fri Nov 02 08:32:41 2012 Thread 1 cannot allocate new log, sequence 1899 Private strand flush not complete Current log# 2 seq# 1898 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Thread 1 advanced to log sequence 1899 (LGWR switch) Current log# 3 seq# 1899 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Fri Nov 02 08:32:45 2012 Archived Log entry 1137 added for thread 1 sequence 1898 ID 0xe48db805 dest 1: Fri Nov 02 09:48:57 2012 Thread 1 advanced to log sequence 1900 (LGWR switch) Current log# 1 seq# 1900 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Fri Nov 02 09:48:58 2012 Archived Log entry 1138 added for thread 1 sequence 1899 ID 0xe48db805 dest 1: Fri Nov 02 10:18:15 2012 Thread 1 cannot allocate new log, sequence 1901 Private strand flush not complete Current log# 1 seq# 1900 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thread 1 advanced to log sequence 1901 (LGWR switch) Current log# 2 seq# 1901 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Fri Nov 02 10:18:19 2012 Archived Log entry 1139 added for thread 1 sequence 1900 ID 0xe48db805 dest 1: Fri Nov 02 10:22:58 2012 Thread 1 cannot allocate new log, sequence 1902 Private strand flush not complete Current log# 2 seq# 1901 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Thread 1 advanced to log sequence 1902 (LGWR switch) Current log# 3 seq# 1902 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Fri Nov 02 10:23:02 2012 Archived Log entry 1140 added for thread 1 sequence 1901 ID 0xe48db805 dest 1: Fri Nov 02 10:27:38 2012 Thread 1 cannot allocate new log, sequence 1903 Checkpoint not complete Current log# 3 seq# 1902 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Thread 1 cannot allocate new log, sequence 1903 Private strand flush not complete Current log# 3 seq# 1902 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO03.LOG Thread 1 advanced to log sequence 1903 (LGWR switch) Current log# 1 seq# 1903 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Fri Nov 02 10:27:45 2012 Archived Log entry 1141 added for thread 1 sequence 1902 ID 0xe48db805 dest 1: Fri Nov 02 10:32:27 2012 Thread 1 cannot allocate new log, sequence 1904 Checkpoint not complete Current log# 1 seq# 1903 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thread 1 cannot allocate new log, sequence 1904 Private strand flush not complete Current log# 1 seq# 1903 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO01.LOG Thread 1 advanced to log sequence 1904 (LGWR switch) Current log# 2 seq# 1904 mem# 0: D:\ORACLE\ORADATA\SIPOREX\REDO02.LOG Fri Nov 02 10:32:34 2012 Archived Log entry 1142 added for thread 1 sequence 1903 ID 0xe48db805 dest 1: Fri Nov 02 10:35:42 2012 Errors in file d:\oracle\diag\rdbms\siporex\siporex\trace\siporex_ora_15856.trc (incident=101353): ORA-03137: TTC protocol internal error : [12333] [8] [49] [50] [] [] [] [] Incident details in: d:\oracle\diag\rdbms\siporex\siporex\incident\incdir_101353\siporex_ora_15856_i101353.trc Fri Nov 02 10:35:44 2012 Trace dumping is performing id=[cdmp_20121102103544] I don't know main reason of this issue as well as how to fixing it. Please help me.

    Read the article

  • How load WebView with another URL when navigated through tab bar viewController

    - by TechFusion
    Hello, I have created window based application, root controller as Tab bar controller. WebView is being loaded in Tab bar interfaced ViewController's View.WebView is created using IB.WebView object declared in ViewController as per below. //ViewController.h @interface ViewController:UIViewController{ IBOutlet UIWebview *Webview; } @property(nonatomic,retain)IBOutlet UIWebview *Webview; @end I am calling [WebView loadrequest] method in -viewDidLoad method and stopLoading will be called in -viewWillDisappear method. I am again reload it in -viewWillAppear:animated method to load it again when tab bar is pressed. //ViewController.m @implementation viewcontroller @synthesize Webview; -(void)viewDidLoad{ [super viewDidLoad]; [self.Webview loadRequest:[NSURLRequest requestWithURL:[NSURL URLWithString:@"www.apple.com"]]]; } -(void)viewWillAppear:(BOOL)animated{ [super viewWillAppear:animated]; [self.Webview reload]; } -(void)viewWillDisappear:(BOOL)animated{ [super viewWillDisappear:animated]; [self.Webview stopLoading]; } I am releasing WebView in -ViewDidUnload method -(void)viewDidUnload{ [super viewDidUnload]; [Webview release]; } -(void)dealloc{ [Webview release]; [super dealloc]; } Does Webview released correctly ? Here how to kill connection with URL when ViewWillDisappear method called ? How to load View with Different URL then it's loaded in -viewDidLoad method when ViewController interfaced tab is pressed ? Means if naviagated from one tab to another that ViewController interface tab which has WebView should load request with another URL. Does it correct to call [self.Webview loadRequest:[NSURLRequest requestWithURL:[NSURL URLWithString:@"www.stackoverflow.com"]]]; this method again in -viewWillAppear:animated method to load with another URL ? Thanks,

    Read the article

  • Visual C# GUI Designer - Recommended way of removing generated event handler-code & basic tutorial

    - by cusack
    Hi, I'm new to the Visual C# designer so these are general and pretty basic question on how to work with the designer. When we for instance add a label to a form and then double-click on it in the Visual C# designer (I'm using Microsoft Visual C# 2008 Express Edition), the following things happen: The designer generates code within Form1.Designer.cs (assume default names for simplicity) to add the label, then with the double-click it will add the event handler label1_Click to the label within Form1.Designer.cs, using the following code this.label1.Click += new System.EventHandler(this.label1_Click); and it adds the event handler method to Form1.cs private void label1_Click(object sender, EventArgs e) { } If I now remove the label only the code within Form1.Designer.cs will be removed but the label1_Click method will stay within Form1.cs even if it isn't used by anything else. But if I'm using reset within Properties-Events for the Click-event from within the designer even the label1_Click method in Form1.cs will be removed. 1.) Isn't that a little inconsistent behavior? 2.) What is the recommended way of removing such generated event handler-code? 3.) What is the best "mental approach"/best practice for using the designer? I would approach it by mental separation in the way that Form1.cs is 100% my responsibility and that on the other hand I'm not touching the code in Form1.Designer.cs at all. Does that make sense or not? Since sometimes the designer removes sth. from Form1.cs I'm not sure about this. 4.) Can you recommend a simple designer tutorial that assumes no Visual C# designer knowledge but expects/doesn't explain C#. The following one is an example of what I would not want it explains what a c#-comment is and I'd prefer text over video as well: http://msdn.microsoft.com/en-us/beginner/bb964631.aspx

    Read the article

  • Instantiate an .aspx that is an embedded resource of an assembly

    - by asbjornu
    I have an ASP.NET (MVC) application in which I would like to load WebForms .aspx files that are embedded as resources in 3rd party assemblies. The reason I want to do this is to make a sort of "plug-in" system where a .dll file can be dropped in a folder and then picked up at runtime to provide additional functionality to the base application. I've gotten the plugin system to work (I'm using MEF) with plugins written in ASP.NET MVC (Views and Controllers), but for plain old ASP.NET (Pages), I've got myself into a bit of a problem. For the execution of the embedded .aspx file (which, in the usual WebForm way Inherits="My.BasePage") I've created a custom VirtualPathProvider, ResourceFile ControllerFactory and PageController. Within the PageController I've overridden the Execute(RequestContext) method and within it I'm trying to compile the .aspx with BuildManager.CreateInstanceFromVirtualPath(virtualPath, type). When doing this, I get the error message "Could not load type 'My.BasePage'", even though I'm giving the BuildManager the System.Type of My.BasePage in the call to CreateInstanceFromVirtualPath. I seem to be stuck at this point. I've tried to Server.Transfer() to the custom VirtualPathProvider handled URL to the same .aspx file, but that fails with the same error message. How can I help BuildManager find out where My.BasePage is defined and how come the Type requiredBaseType parameter of CreateInstanceFromVirtualPath seems to be ignored? I've tried to call BuildManager.AddReferencedAssembly(), but that only fails with "This method can only be called during the application's pre-start initialization stage". MSDN says: "The method must be called during the Application_PreStartInit stage of the application", but I have no such event in my HttpApplication object and find absolutely zero information about it on the internet. Either way, I don't want to be calling BuildManager.AddReferencedAssembly() in or before the Application_Start event, since that makes me have to recycle the whole application to be able to add new plugins to the system. Does anyone have any clues? Any other ideas on how I can "execute" an .aspx file that is embedded as a resource within an assembly through reflection? Can I for instance pre-compile the .aspx file within the same assembly as the base Page class it inherits?

    Read the article

  • How can I force Javascript garbage collection in IE? IE is acting very slow after AJAX calls & DOM

    - by RenderIn
    I have a page with chained drop-downs. Choosing an option from the first select populates the second, and choosing an option from the second select returns a table of matching results using the innerHtml function on an empty div on the page. The problem is, once I've made my selections and a considerable amount of data is brought onto the page, all subsequent Javascript on the page runs exceptionally slowly. It seems as if all the data I pulled back via AJAX to populate the div is still hogging a lot of memory. I tried setting the return object which contains the AJAX results to null after calling innerHtml but with no luck. Firefox, Safari, Chrome and Opera all show no performance degradation when I use Javascript to insert a lot of data into the DOM, but in IE it is very apparent. To test that it's a Javascript/DOM issue rather than a plain old IE issue, I created a version of the page that returns all the results on the initial load, rather than via AJAX/Javascript, and found IE had no performance problems. FYI, I'm using jQuery's jQuery.get method to execute the AJAX call. EDIT This is what I'm doing: <script type="text/javascript"> function onFinalSelection() { var searchParameter = jQuery("#second-select").val(); jQuery.get("pageReturningAjax.php", {SEARCH_PARAMETER: searchParameter}, function(data) { jQuery("#result-div").get(0).innerHtml = data; //jQuery("#result-div").html(data); //Tried this, same problem data = null; }, "html"); } </script>

    Read the article

  • E2251 Ambiguous overloaded call to ....

    - by Eric M
    I inherited some Delphi components/code that currently compiles with C++ Builder 2007. I'm simply now trying to compile the components with C++ Builder RAD XE. I don't know Delphi (object pascal). Here are the versions of the 'Supports' functions that appear to be in conflict. Is there a compiler switch I can use to make RAD XE backward compatible? Or is there something I can do to these function calls to correct the ambiguous nature? {$IFNDEF DELPHI5} procedure FreeAndNil(var Obj); var Temp: TObject; begin Temp := TObject(Obj); Pointer(Obj) := nil; Temp.Free; end; function Supports(const Instance: IUnknown; const Intf: TGUID; out Inst): Boolean; overload; begin Result := (Instance <> nil) and (Instance.QueryInterface(Intf, Inst) = 0); end; function Supports(Instance: TObject; const Intf: TGUID; out Inst): Boolean; overload; var Unk: IUnknown; begin Result := (Instance <> nil) and Instance.GetInterface(IUnknown, Unk) and Supports(Unk, Intf, Inst); end; {$ENDIF} {$IFNDEF DELPHI6} function Supports(const Instance: TObject; const IID: TGUID): Boolean; var Temp: IUnknown; begin Result := Supports(Instance, IID, Temp); end; {$ENDIF}

    Read the article

  • How to play non buffered .wav with MediaStreamSource implementation in Silverlight 4?

    - by kyrisu
    Background I'm trying to stream a wave file in Silverlight 4 using MediaStreamSource implementation found here. The problem is I want to play the file while it's still buffering, or at least give user some visual feedback while it's buffering. For now my code looks like that: private void button1_Click(object sender, RoutedEventArgs e) { HttpWebRequest request = (HttpWebRequest)HttpWebRequest.Create(new Uri(App.Current.Host.Source, "../test.wav")); //request.ContentType = "audio/x-wav"; request.AllowReadStreamBuffering = false; request.BeginGetResponse(new AsyncCallback(RequestCallback), request); } private void RequestCallback(IAsyncResult ar) { this.Dispatcher.BeginInvoke(delegate() { HttpWebRequest request = (HttpWebRequest)ar.AsyncState; HttpWebResponse response = (HttpWebResponse)request.EndGetResponse(ar); WaveMediaStreamSource wavMss = new WaveMediaStreamSource(response.GetResponseStream()); try { me.SetSource(wavMss); } catch (InvalidOperationException) { // This file is not valid } me.Play(); }); } The problem is that after settings request.AllowREadStreamBuffer to false the stream does not support seeking and the above mentioned implementation throws an exception (keep in mind I've put some of the position setting logic into if(stream.CanSeek) block): Read is not supported on the main thread when buffering is disabled Question Is there a way to play wav stream without buffering it in advance?

    Read the article

  • How to implement progress bar and backgroundworker for database calls C#?

    - by go-goo-go
    How to implement progress bar and backgroundworker for database calls C#? I do have some methods that deal with large amounts of data. They do last a lot, so in my windows application, i wanna do something to tell users that the data are being processed. So i thought of using progress bar or status strip label, but since there is a single ui thread, the thread where the database-dealing methods are executed, ui controls are not updated, so progress bar or status strip label are useless to me. I've already seen some examples, but they deal with for-loops, ex: for(int i = 0; i < count; i++){ System.Threading.Thread.Sleep(70); // ... do analysis ... bgWorker.ReportProgress((100 * i) / count);} private void bgWorker_ProgressChanged(object sender, ProgressChangedEventArgs e){ progressBar.Value = Math.Min(e.ProgressPercentage, 100);} Can anybody give an example where I can use a method call, not a for-loop, and let the progress bar run while this method is executing??? thnx in advance, any help and hint is highly appreciated.

    Read the article

  • Rails ActiveRecord - Best way to perform an include?

    - by dwhite
    I have three models: class Book < ActiveRecord::Base has_many :collections has_many :users, :through => :collections end class User < ActiveRecord::Base has_many :collections has_many :books, :through => :collections end class Collection < ActiveRecord::Base belongs_to :book belongs_to :user end I'm trying to display a list of the books and have a link to either add or remove from the user's collection. I can't quite figure out the best syntax to do this. For example, if I do the following: Controller class BooksController < ApplicationController def index @books = Book.all end end View ... <% if book.users.include?(current_user) %> ... or obviously the inverse... ... <% if current_user.books.include?(book) %> ... Then queries are sent for each book to check on that include? which is wasteful. I was thinking of adding the users or collections to the :include on the Book.all, but I'm not sure this is the best way. Effectively all I need is the book object and just a boolean column of whether or not the current user has the book in their collection, but I'm not sure how to forumlate the query in order to do that. Thanks in advance for your help. -Damien

    Read the article

  • Silverlight 4 WriteableBitmap ScaleTransform Exception but was working in v3

    - by Imran
    I am getting the following exception for code that used to work in silverlight 3 but has stopped working since upgrading to silverlight 4: System.AccessViolationException was unhandled Message=Attempted to read or write protected memory. This is often an indication that other memory is corrupt. namespace SilverlightApplication1 { public partial class MainPage : UserControl { public MainPage() { InitializeComponent(); } private void button1_Click(object sender, RoutedEventArgs e) { var OpenFileDialog = new OpenFileDialog(); OpenFileDialog.Filter = "*.jpg|*.jpg"; if (OpenFileDialog.ShowDialog() == true) { var file = OpenFileDialog.Files.ToArray()[0]; ScaleStreamAsBitmap(file.OpenRead(), 200); } } public static WriteableBitmap ScaleStreamAsBitmap(Stream file, int maxEdgeLength) { file.Position = 0; var src = new BitmapImage(); var uiElement = new System.Windows.Controls.Image(); WriteableBitmap b = null; var t = new ScaleTransform(); src.SetSource(file); uiElement.Source = src; //force render uiElement.Effect = new DropShadowEffect() { ShadowDepth = 0, BlurRadius = 0 }; ; //calc scale double scaleX = 1; double scaleY = 1; if (src.PixelWidth > maxEdgeLength) scaleX = ((double)maxEdgeLength) / src.PixelWidth; if (src.PixelHeight > maxEdgeLength) scaleY = ((double)maxEdgeLength) / src.PixelHeight; double scale = Math.Min(scaleX, scaleY); t.ScaleX = scale; t.ScaleY = scale; b = new WriteableBitmap(uiElement, t); return b; } } } Thanks

    Read the article

  • Why is jQuery so widely adopted versus other Javascript frameworks?

    - by Andrew Moore
    I manage a group of programmers. I do value my employees opinion but lately we've been divided as to which framework to use on web projects. I personally favor MooTools, but some of my team seems to want to migrate to jQuery because it is more widely adopted. That by itself is not enough for me to allow a migration. I have used both jQuery and MooTools. This particular essay tends to reflect how I feel about both frameworks. jQuery is great for DOM Manipulation, but seem to be limited to helping you do that. Feature wise, both jQuery and MooTools allow for easy DOM Selection and Manipulation: // jQuery $('#someContainer div[class~=dialog]') .css('border', '2px solid red') .addClass('critical'); // MooTools $('#someContainer div[class~=dialog]') .setStyle('border', '2px solid red') .addClass('critical'); Both jQuery and MooTools allow for easy AJAX: // jQuery $('#someContainer div[class~=dialog]') .load('/DialogContent.html'); // MooTools (Using shorthand notation, you can also use Request.HTML) $('#someContainer div[class~=dialog]') .load('/DialogContent.html'); Both jQuery and MooTools allow for easy DOM Animation: // jQuery $('#someContainer div[class~=dialog]') .animate({opacity: 1}, 500); // MooTools (Using shorthand notation, you can also use Fx.Tween). $('#someContainer div[class~=dialog]') .set('tween', {duration: 500}) .tween('opacity', 1); jQuery offers the following extras: Large community of supporters Plugin Repository Integration with Microsoft's ASP.NET and VisualStudio Used by Microsoft, Google and others MooTools offers the following extras: Object Oriented Framework with Classic OOP emulation for JS Extended native objects Higher consistency between browsers for native functions support. More easy code reuse Used by The World Wide Web Consortium, Palm and others. Given that, it seems that MooTools does everything jQuery does and more (some things I cannot do in jQuery and I can in MooTools) but jQuery has a smaller learning curve. So the question is, why did you or your team choose jQuery over another JavaScript framework? Note: While I know and admit jQuery is a great framework, there are other options around and I'm trying to take a decision as to why jQuery should be our choice versus what we use right now (MooTools)?

    Read the article

  • Can you force a MPMoviePlayerPlaybackDidFinishNotification ?

    - by Jonathan
    Hi, I have several movies that are played and presented using this code. As you can see I also have removed the default movie controls and have added a custom overlay which essentially just stops the video. Here is my problem... When I stop the movie with my custom overlay button, I don't seem to be getting the 'MPMoviePlayerPlaybackDidFinishNotification' Note: everything works normal if I let the movie play through and it stop by itself. Is the any way of 'forcing' the PlaybackDidFinish notification? Can I do something like this [self moviePlayBackDidFinish:something]; ? Thank You! - (void) playMovie { NSString *path = [[NSBundle mainBundle] pathForResource:@"movie_frog" ofType:@"m4v"]; NSURL *url = [NSURL fileURLWithPath:path]; MPMoviePlayerController *mp = [[MPMoviePlayerController alloc] initWithContentURL:url]; if(mp) { self.myMoviePlayer = mp; [mp release]; //movie view [self.view addSubview:myMoviePlayer.view]; myMoviePlayer.view.frame = CGRectMake(0.0,0.0,480,320); self.myMoviePlayer.controlStyle = MPMovieControlStyleNone; [self.myMoviePlayer play]; //videoNav _videoNav = [[videoNav alloc] initWithNibName:@"videoNav" bundle:nil]; [self.view addSubview:_videoNav.view]; [[NSNotificationCenter defaultCenter] addObserver:self selector:@selector(moviePlayBackDidFinish:) name:MPMoviePlayerPlaybackDidFinishNotification object:nil]; } }

    Read the article

  • Problem loading Oracle client libraries when running in a NAnt build

    - by Chris Farmer
    I am trying to use dbdeploy to manage Oracle schema changes. I can run it successfully from the command line to get it to generate my change scripts, but when I try to execute it via the dbdeploy NAnt task running through TeamCity, I get an error: System.Data.OracleClient requires Oracle client software version 8.1.7 or greater. I do have the Oracle 10.2.0.2 client software installed. It's the first entry in the system path, and the dbdeploy.exe app is able to successfully negotiate an Oracle connection. The dbdeploy code dynamically loads the System.Data.OracleClient assembly, which in-turn tries to use the Oracle client bits to talk to the database. This is what is failing in my NAnt environment. I have verified the following points: The same user identity is running the process in both cases The same working directory is used in both cases The same dbdeploy code is running in both cases and with the same supplied parameters The same database connection string is being used in both cases The same ADO.NET assembly is being dynamically loaded in both cases (System.Data.OracleClient, Version=1.0.5000.0, Culture=neutral, PublicKeyToken=b77a5c561934e089) Here's the top of the stack trace during the error: at System.Data.OracleClient.OCI.DetermineClientVersion() at System.Data.OracleClient.OracleInternalConnection.OpenOnLocalTransaction (String userName, String password, String serverName, Boolean integratedSecurity, Boolean unicode, Boolean omitOracleConnectionName) at System.Data.OracleClient.OracleInternalConnection..ctor( OracleConnectionString connectionOptions) at System.Data.OracleClient.OracleConnectionFactory.CreateConnection( DbConnectionOptions options, Object poolGroupProviderInfo, DbConnectionPool pool, DbConnection owningObject) at System.Data.ProviderBase.DbConnectionFactory.CreatePooledConnection( DbConnection owningConnection, DbConnectionPool pool, DbConnectionOptions options) at System.Data.ProviderBase.DbConnectionPool.CreateObject( DbConnection owningObject) at System.Data.ProviderBase.DbConnectionPool.UserCreateRequest( DbConnection owningObject) at System.Data.ProviderBase.DbConnectionPool.GetConnection( DbConnection owningObject) at System.Data.ProviderBase.DbConnectionFactory.GetConnection( DbConnection owningConnection) at System.Data.ProviderBase.DbConnectionClosed.OpenConnection( DbConnection outerConnection, DbConnectionFactory connectionFactory) at System.Data.OracleClient.OracleConnection.Open() at Net.Sf.Dbdeploy.Database.DatabaseSchemaVersionManager. GetCurrentVersionFromDb() My main question is this: how can I discover what's different about these running environments to see why my Oracle client software can't be loaded?

    Read the article

  • Support for nested model and class validation with ASP.NET MVC 2.0

    - by Diep-Vriezer
    I'm trying to validate a model containing other objects with validation rules using the System.ComponentModel.DataAnnotations attributes was hoping the default MVC implementation would suffice: var obj = js.Deserialize(json, objectInfo.ObjectType); if(!TryValidateModel(obj)) { // Handle failed model validation. } The object is composed of primitive types but also contains other classes which also use DataAnnotications. Like so: public class Entry { [Required] public Person Subscriber { get; set; } [Required] public String Company { get; set; } } public class Person { public String FirstName { get; set;} [Required] public String Surname { get; set; } } The problem is that the ASP.NET MVC validation only goes down 1 level and only evaluates the properties of the top level class, as can be read on digitallycreated.net/Blog/54/deep-inside-asp.net-mvc-2-model-metadata-and-validation. Does anyone know an elegant solution to this? I've tried xVal, but they seem to use a non-recursive pattern (http://blog.stevensanderson.com/2009/01/10/xval-a-validation-framework-for-aspnet-mvc/). Someone must have run into this problem before right? Nesting objects in your model doesn't seem so weird if you're designing a web service.

    Read the article

  • How to change the border color of a Grouped UITableView

    - by ctpenrose
    This concerns iPhoneOS-sdk-3.2 I am having difficulty changing the border color of a grouped UITableView. I can change the cell background color, separator color, text color, quite easily now, and the rounded corners clip correctly, even when highlighted with whatever colors I have chosen. However the surrounding border remains infuriatingly gray despite many different attempts. I have read all of the related posts I can find via Google, let alone stackoverflow. I have tried both a programmatic and xib-based solution and both provide the same results. I will share the programmatic version below: I have a UIViewController subclass rather than a UITableViewController subclass to act as a UITableView delegate -- I chose this route as I am coding on the iPad and UITableViewController reportedly takes over the whole screen. loadView method of my UIViewController subclass: - (void) loadView { self.view = [[UIView alloc] initWithFrame:[[UIScreen mainScreen] applicationFrame]]; [self.view release]; self.view.backgroundColor = [UIColor blackColor]; // add and configure UITableView CGRect tableViewRect = CGRectMake(0., 0., 256., 768.); myTableView = [[UITableView alloc] initWithFrame:tableViewRect style:UITableViewStyleGrouped]; // set the tableview delegate to this object and the datasource to the datasource which has already been set myTableView.delegate = self; myTableView.dataSource = self; myTableView.sectionIndexMinimumDisplayRowCount=1; myTableView.backgroundColor = [UIColor clearColor]; myTableView.separatorColor = [UIColor whiteColor]; myTableView.separatorStyle = UITableViewCellSeparatorStyleSingleLine; myTableView.opaque = NO; // add the table view to our background view [self.view addSubview:myTableView]; [myTableView release]; }

    Read the article

  • NSTextField autocomplete

    - by Rasmus Styrk
    Does anyone know of any class or lib that can implement autocompletion to an NSTextField? I'am trying to get the standard autocmpletion to work but it is made as a synchronous api. I get my autocompletion words via an api call over the internet. What have i done so far is: - (void)controlTextDidChange:(NSNotification *)obj { if([obj object] == self.searchField) { [self.spinner startAnimation:nil]; [self.wordcompletionStore completeString:self.searchField.stringValue]; if(self.doingAutocomplete) return; else { self.doingAutocomplete = YES; [[[obj userInfo] objectForKey:@"NSFieldEditor"] complete:nil]; } } } When my store is done, i have a delegate that gets called: - (void) completionStore:(WordcompletionStore *)store didFinishWithWords:(NSArray *)arrayOfWords { [self.spinner stopAnimation:nil]; self.completions = arrayOfWords; self.doingAutocomplete = NO; } The code that returns the completion list to the nstextfield is: - (NSArray *)control:(NSControl *)control textView:(NSTextView *)textView completions:(NSArray *)words forPartialWordRange:(NSRange)charRange indexOfSelectedItem:(NSInteger *)index { *index = -1; return self.completions; } My problem is that this will always be 1 request behind and the completion list only shows on every 2nd char the user inputs. I have tried searching google and SO like a mad man but i cant seem to find any solutions.. Any help is much appreciated.

    Read the article

  • Creating a Custom EventAggregator Class

    - by Phil
    One thing I noticed about Microsoft's Composite Application Guidance is that the EventAggregator class is a little inflexible. I say that because getting a particular event from the EventAggregator involves identifying the event by its type like so: _eventAggregator.GetEvent<MyEventType>(); But what if you want different events of the same type? For example, if a developer wants to add a new event to his application of type CompositePresentationEvent<int>, he would have to create a new class that derives from CompositePresentationEvent<int> in a shared library somewhere just to keep it separate from any other events of the same type. In a large application, that's a lot of little two-line classes like the following: public class StuffHappenedEvent : CompositePresentationEvent<int> {} public class OtherStuffHappenedEvent : CompositePresentationEvent<int> {} I don't really like that approach. It almost feels dirty to me, partially because I don't want a million two-line event classes sitting around in my infrastructure dll. What if I designed my own simple event aggregator that identified events by an event ID rather than the event type? For example, I could have an enum such as the following: public enum EventId { StuffHappened, OtherStuffHappened, YetMoreStuffHappened } And my new event aggregator class could use the EventId enum (or a more general object) as a key to identify events in the following way: _eventAggregator.GetEvent<CompositePresentationEvent<int>>(EventId.StuffHappened); _eventAggregator.GetEvent<CompositePresentationEvent<int>>(EventId.OtherStuffHappened); Is this good design for the long run? One thing I noticed is that this reduces type safety. In a large application, is this really as important of a concern as I think it is? Do you think there could be a better alternative design?

    Read the article

< Previous Page | 1061 1062 1063 1064 1065 1066 1067 1068 1069 1070 1071 1072  | Next Page >