Search Results

Search found 8323 results on 333 pages for 'execute'.

Page 107/333 | < Previous Page | 103 104 105 106 107 108 109 110 111 112 113 114  | Next Page >

  • RDA Health Checks for SOA

    - by ShawnBailey
    What is a health check in RDA? A health check evaluates something in your environment to determine whether a change needs to be considered in order to avoid a problem or optimize fuctionality. Examples of what this 'something' might be are: Configuration Parameters JVM Options Runtime Statistics What have we done for SOA? In the latest release of RDA, 4.30, we have added a Rule Set for SOA called 'Oracle SOA 11g (11.1.1) Post Installation (Generic)'. This Rule Set contains 14 SOA related health checks. These checks were all derived from common issues / solutions we see in support of the SOA product. Many of the recommendations come from the product documentation while others are covered in the SOA Knowledge Base. Our goal is that you will be able to easily identify the areas of concern and understand the guidance available from the output of the Rule Set. Running the health checks for SOA The rules that the checks use are installed with RDA and bundled by product or functional area into what are called 'Rule Sets'. To view the available Rule Sets simply run the command from the RDA home location: rda.cmd (or .sh) -dT hcve This will bring up a list of the available HCVE (Health Check / Verification Engine) Rule Sets. Each Rule Set contains a group of related rules that are used for evalutation and display of results. A rule can be considered synonymous with a single health check and they are assigned an ID, Name and Description that can be seen when they are executed. The Rule Set for SOA is option number 11 and you just enter this selection at the prompt. The Rule Set will then execute to completion. After running an HCVE Rule Set the tool will write the output to the RDA_HOME/output folder. The simplest way to view the output is to drag the .htm file to a browser but of course it can also be uploaded to a Service Request for evaluation by Oracle Support. Many of the Rule Sets will prompt you for information before they can execute their rules but the SOA Rule Set will identify the SOA domains configured in your RDA setup.cfg file. This means that you don't need to answer all of the questions again about where stuff is but it also means that you must have configured RDA for SOA. To run the Rule Set: Download the latest version of RDA from MOS Doc ID 314422.1 Configure RDA for your SOA domains. Detailed steps can be found here In it's simplest form the command is 'rda.cmd (.sh) -S SOA' Go to the RDA home location and enter the command 'rda.cmd (or .sh) -dT hcve' Select option '11' It should be noted that this our first release of a SOA Rule Set so there will probably be some things we need to clean up or fix. None of these rules will actually modify anything on your system as they are read only and do the evaluations internally. Please let us know if you have any issues with the rules or ideas for new ones so we can make them as useful as possible. The Checks Here is a list of the SOA health checks by ID, Name and Description. ID Name Description A00100 SOA Domain Homes Lists the SOA domains that were indentified from the RDA setup.cfg file A00200 Coherence Protocol Conflict Checks to see if you have both Unicast and Multicast configured in the same domain. Checks both the setDomainEnv and config.xml entries (if it exists). We recommend Unicast with fully qualified host names or IP addresses. A00210 Coherence Fully Qualified Host Checks that the host names are fully qualified or that IP addresses are used. Will fail if unqualified host names are detected. A00220 Unicast Local Host Checks that the Coherence localhost is specified for use with Unicast A00300 JTA Timeout Checks that the JTA timeout is configured for the domain and lists the value. The bundled rule will only list the current values of the JTA timeout for each SOA Domain. In the future the rule with fail with a warning if the value is 300 seconds or lower. It is recommended that timeouts follow the pattern 'syncMaxWaitTime' < EJB Timeouts < JTA Timeout. The 300 second value is important because the EJB Timeouts default to 300 seconds. Additional information can be found in MOS Doc ID 880313.1. A00310 XA Max Time Checks that the JTA Maximum XA call time is set for the domain. Fails if it is not explicitly set or if the value is less than or equal to the default of 12000 ms. A00320 XA Timeout Checks that the XA timeout is enabled and that the value is '0' for the SOA Data Source (SOADataSource-jdbc.xml) A00330 JDBC Statement Timeout Checks that the Statement Timeout is set for all SOA Data Sources. Fails if the value is not set or if it is set to the default of -1. A00400 XA Driver Checks that the SOA Data Source is configured to use an XA driver. Fails if it is not. A00410 JDBC Capacity Settings Checks that the minimum and maximum capacity are equal for all SOA Data Sources. Fails if they are not and lists specifically which data sources failed. A00500 SOA Roles Checks that the default SOA roles 'SOAAdmin' and 'SOAOperator' are configured for the soa-infra application in the file sytem-jazn-data.xml. Fails if they are not. A00700 SOA-INFRA Deployment Checks that the soa-infra application is deployed to either a cluster, all members of a cluster or a stand alone server. A00710 SOA Deployments Checks that the SOA related applications are deployed to the same domain members as soa-infra. A00720 SOA Library Deployments Checks that the SOA related libraries are deployed to the same domain members as soa-infra. A00730 Data Source Deployments Checks that the SOA Data Sources are all targeted to the same domain members as soa-infra

    Read the article

  • Backbone.js, Rails and code duplication

    - by Matteo Pagliazzi
    I'm building a web app and I need a JS framework like Backbone.js to work with my backend rovided by Rails that mostly return JSON objects after DB queries. Searching on the web I've discovered Backbone which seems to be complete, quite populare and actively developed but I've noticed that a lot of things done by Backbone are simply a duplicte of the works done by Rails: for example validation and models. My idea of "perfect" (for my actual needs) JS mvc (it can't be called mvc but i don't have any other names) is something really simple that has a function for each action in my Rails controller that are triggered by a specific event (user/hash changes, click on a button...) and send requests to the server that respond with a JSON object then I'll load a template or execute some JS code. Do you have any concern/suggestion about my idea? Do you know some "micro" js framework like what i have described? If you have worked with backone.js + rails what can you suggest me?

    Read the article

  • T-SQL User-Defined Functions: the good, the bad, and the ugly (part 1)

    - by Hugo Kornelis
    So you thought that encapsulating code in user-defined functions for easy reuse is a good idea? Think again! SQL Server supports three types of user-defined functions. Only one of them qualifies as good. The other two – well, the title says it all, doesn’t it? The bad: scalar functions A scalar user-defined function (UDF) is very much like a stored procedure, except that it always returns a single value of a predefined data type – and because of that property, it isn’t invoked with an EXECUTE statement,...(read more)

    Read the article

  • "AND Operator" in PAM

    - by d_inevitable
    I need to prevent users from authenticating through Kerberos when the encrypted /home/users has not yet been mounted. (This is to avoid corrupting the ecryptfs mountpoint) Currently I have these lines in /etc/pam.d/common-auth: auth required pam_group.so use_first_pass auth [success=2 default=ignore] pam_krb5.so minimum_uid=1000 try_first_pass auth [success=1 default=ignore] pam_unix.so nullok_secure try_first_pass I am planning to use pam_exec.so to execute a script that will exit 1 if the ecyptfs mounts are not ready yet. Doing this: auth required pam_exec.so /etc/security/check_ecryptfs will lock me out for good if ecryptfs for some reason fails. In such case I would like to at least be able to login with a local (non-kerberos) user to fix the issue. Is there some sort of AND-Operator in which I can say that login through kerberos+ldap is only sufficient if both kerberos authentication and the ecryptfs mount has succeeded?

    Read the article

  • Unit testing time-bound code

    - by maasg
    I'm currently working on an application that does a lot of time-bound operations. That is, based on long now = System.currentTimeMillis();, and combined with an scheduler, it will calculate periods of time that parametrize the execution of some operations. e.g.: public void execute(...) { // executed by an scheduler each x minutes final int now = (int) TimeUnit.MILLISECONDS.toSeconds(System.currentTimeMillis()); final int alignedTime = now - now % getFrequency() ; final int startTime = alignedTime - 2 * getFrequency(); final int endTimeSecs = alignedTime - getFrequency(); uploadData(target, startTime, endTimeSecs); } Most parts of the application are unit-tested independently of time (in this case, uploadData has a natural unit test), but I was wondering about best practices for testing time-bound parts that rely on System.currentTimeMillis() ?

    Read the article

  • tail stops displaying in case of a log rotation

    - by Rudy Vissers
    I have to tail the log of a server (servicemix) and the log rotation is enabled. As soon as the rotation happens, tail stops displaying. I did some investigations and it is a bug in Debian : Debian Bug Report. The bug has been around for a long time ago. Does anyone knows if this bug in Ubuntu is to be fixed? I'm on Ubuntu 12.04 64 bit. I don't have to mention that this bug is total hell! Every time I have the problem, I have to interrupt the command tail and re-execute the command!

    Read the article

  • How disable mysql command in sudoers file?

    - by Carlos A. Junior
    How i can disable /usr/bin/mysql command in sudoers file ? ... Actually I've tryed use with this way: %tailonly ALL=!/usr/bin/mysql But when i'm access if user 'tailonly' of group 'tailonly', this command still enabled. In resume, i'm only want that 'tailonly' user access 'tail -f /usr/app/*.log' ... This is possible ? Edit: With this config, the user 'tailonly' still can access mysql terminal with 'mysql' command: $: sudo su $: visudo Cmnd_Alias MYSQL = /usr/bin/mysql Cmnd_Alias TAIL=/usr/bin/tail -f /jacad/jacad3/logs/*.log # User privilege specification root ALL=(ALL:ALL) ALL # Members of the admin group may gain root privileges %admin ALL=(ALL) ALL # Allow members of group sudo to execute any command %sudo ALL=(ALL:ALL) ALL %swa ALL=/etc/init.d/jacad3 stop %swa ALL=/etc/init.d/jacad3 start %swa ALL=/etc/init.d/jacad3 restart %swa ALL=sudoedit /jacad/jacad3/bin/jacad_start.sh %tailonly ALL=ALL,!MYSQL

    Read the article

  • Symbolic link not allowed or link target not accessible: /var/www on Ubuntu 11.04

    - by Jamie Hutber
    I am getting a 403 when i access http://mayfieldafc.local/ upon looking in the apache logs i am getting [Wed Nov 16 12:32:59 2011] [error] [client 127.0.0.1] Symbolic link not allowed or link target not accessible: /var/www I have what i believe to be the correct permissions set on /var/www. hutber can create and delete files, hutber being my user. I can also execute as program on this folder. in mayfields vhost its: <Directory /var/www/mayfieldafc/docroot> Options +FollowSymLinks AllowOverride None Order allow,deny Allow from all </Directory> I am pulling my hair out not being able to work on my sites with my work ubuntu install. I know of nothing else that could be effecting this. So any ideas?

    Read the article

  • Trying to setup first DirectX project (don't understand the error) [on hold]

    - by user1157885
    I've just started learning DirectX with the book "3D Game Programming with DirectX". I just finished setting up all the paths and adding the code to the project which I think I did correctly, but I get this massive error which I don't really understand and is hard to google. Could someone tell me what it means and how to fix it? Error 1 error TRK0002: Failed to execute command: ""C:\Program Files (x86)\Microsoft DirectX SDK (June 2010)\Utilities\bin\x64\fxc.exe" /nologo /Emain /Fo "C:\Desktop\DirectX 11 Projects\box\Win32Project2\Debug\color.cso" /Od /Zi "....\Book Files\3DGameProg\DVD\Code\Chapter 6 Drawing in Direct3D\Box\FX\color.fx"". The handle is invalid.

    Read the article

  • Rewriting URL to get Wordpress "permalink" type URL

    - by user1472575
    I would like my users to enter http://mywebsite.com/the-name-of-my-post and have the following execute: http://mywebsite.com/Default.aspx#&&the-name-of-my-post ...which is what the ScriptManager generates at runtime. I have created an ASP.NET site to replace a Wordpress site that creates "permalinks". This site was around for about 2 years so there are lots of bookmarks and references to these "permalinks" on the search engines etc. Also are there any modules I have to include in my website to get this to work? Is there any configuration that I have to ask my hosting company to make so that this works?

    Read the article

  • Screen problems

    - by Erick
    I struggled a lot in order to install Ubuntu because of a problem with the video drivers caused by when installing the driver and after turning it on it just appears a black screen, which worked for me was to use the terminal with sudo setpci -s 00:02.0 F4.B=0 and the screen starts, but after rebooting the changes won't remain and I have to run that command again. My question is: How can I make the changes permanent and not to be in need to execute that command always when I shut it down? Original Question in Spanish: Problemas con pantalla He batallado mucho al instalar ubuntu por el problema con el controlador de video ya que al instalarlo al encenderla aparece solo una pantalla negra lo que me funciono fue usar desde consola sudo setpci -s 00:02.0 F4.B=0 enciende la pantalla pero al reiniciarla los cambios no se quedan guardados y tengo que volver a ejecutar ese comando mi pregunta es ¿como hacerle para que los cambios queden igual y no tener que estar ejecutando eso siempre que la apago?

    Read the article

  • Handling packet impersonating in client-server model online game

    - by TheDespite
    I am designing a server-client model game library/engine. How do I, and should I even bother to handle frequent update packet possible impersonating? In my current design anyone could copy a packet from someone else and modify it to execute any non-critical action for another client. I am currently compressing all datagrams so that adds just a tad of security. Edit: One way I thought about was to send a unique "key" to the verified client every x_time and then the client has to add that to all of it's update packets until a new key is sent. Edit2: I should have mentioned that I am not concerned about whether the actions described in the packet are available to the client at the time, this is all checked by the server which I thought was obvious. I am only concerned about someone sending packets for another client.

    Read the article

  • Override an IOCTL Handler in PQOAL

    - by Kate Moss' Big Fan
    When porting or creating a BSP to a new platform, we often need to make change to OEMIoControl or HAL IOCTL handler for more specific. Since Microsoft introduced PQOAL in CE 5.0 and more and more BSP today leverages PQOAL to simplify the OAL, we no longer define the OEMIoControl directly. It is somehow analogous to migrate from pure Windows SDK to MFC; people starts to define those MFC handlers and forgot the WinMain and the big message loop. If you ever take a look at the interface between OAL and Kernel, PUBLIC\COMMON\OAK\INC\oemglobal.h, the pfnOEMIoctl is still there just as the entry point of Windows Program is WinMain since day one. (For those may argue about pfnOEMIoctl is not OEMIoControl, I will encourage you to dig into PRIVATE\WINCEOS\COREOS\NK\OEMMAIN\oemglobal.c which initialized pfnOEMIoctl to OEMIoControl. The interface is just to split OAL and Kernel which no longer linked to one executable file in CE 6, all of the function signature is still identical) So let's trace into PQOAL to realize how it implements OEMIoControl and how can we override an IOCTL handler we interest. First thing to know is the entry point (just as finding the WinMain in MFC), OEMIoControl is defined in PLATFORM\COMMON\SRC\COMMON\IOCTL\ioctl.c. Basically, it does nothing special but scan a pre-defined IOCTL table, g_oalIoCtlTable, and then execute the handler. (The highlight part) Other than that is just for error handling and the use of critical section to serialize the function. BOOL OEMIoControl(     DWORD code, VOID *pInBuffer, DWORD inSize, VOID *pOutBuffer, DWORD outSize,     DWORD *pOutSize ) {     BOOL rc = FALSE;     UINT32 i; ...     // Search the IOCTL table for the requested code.     for (i = 0; g_oalIoCtlTable[i].pfnHandler != NULL; i++) {         if (g_oalIoCtlTable[i].code == code) break;     }     // Indicate unsupported code     if (g_oalIoCtlTable[i].pfnHandler == NULL) {         NKSetLastError(ERROR_NOT_SUPPORTED);         OALMSG(OAL_IOCTL, (             L"OEMIoControl: Unsupported Code 0x%x - device 0x%04x func %d\r\n",             code, code >> 16, (code >> 2)&0x0FFF         ));         goto cleanUp;     }            // Take critical section if required (after postinit & no flag)     if (         g_ioctlState.postInit &&         (g_oalIoCtlTable[i].flags & OAL_IOCTL_FLAG_NOCS) == 0     ) {         // Take critical section                    EnterCriticalSection(&g_ioctlState.cs);     }     // Execute the handler     rc = g_oalIoCtlTable[i].pfnHandler(         code, pInBuffer, inSize, pOutBuffer, outSize, pOutSize     );     // Release critical section if it was taken above     if (         g_ioctlState.postInit &&         (g_oalIoCtlTable[i].flags & OAL_IOCTL_FLAG_NOCS) == 0     ) {         // Release critical section                    LeaveCriticalSection(&g_ioctlState.cs);     } cleanUp:     OALMSG(OAL_IOCTL&&OAL_FUNC, (L"-OEMIoControl(rc = %d)\r\n", rc ));     return rc; }   Where is the g_oalIoCtlTable? It is defined in your BSP. Let's use DeviceEmulator BSP as an example. The PLATFORM\DEVICEEMULATOR\SRC\OAL\OALLIB\ioctl.c defines the table as const OAL_IOCTL_HANDLER g_oalIoCtlTable[] = { #include "ioctl_tab.h" }; And that leads to PLATFORM\DEVICEEMULATOR\SRC\INC\ioctl_tab.h which defined some of IOCTL handler but others are defined in oal_ioctl_tab.h which is under PLATFORM\COMMON\SRC\INC\. Finally, we got the full table body! (Just like tracing MFC, always jumping back and forth). The format of table is very straight forward, IOCTL code, Flags and Handler Function // IOCTL CODE,                          Flags   Handler Function //------------------------------------------------------------------------------ { IOCTL_HAL_INITREGISTRY,                   0,  OALIoCtlHalInitRegistry     }, { IOCTL_HAL_INIT_RTC,                       0,  OALIoCtlHalInitRTC          }, { IOCTL_HAL_REBOOT,                         0,  OALIoCtlHalReboot           }, The PQOAL scans through the table until it find a matched IOCTL code, then invokes the handler function. Since it scans the table from the top which means if we define TWO handler with same IOCTL code, the first one is always invoked with no exception. Now back to the PLATFORM\DEVICEEMULATOR\SRC\INC\ioctl_tab.h, with the following table { IOCTL_HAL_INITREGISTRY,                   0,  OALIoCtlDeviceEmulatorHalInitRegistry     }, ... #include <oal_ioctl_tab.h> Note the IOCTL_HAL_INITREGISTRY handler are defined in both BSP's local ioctl_tab.h and the common oal_ioctl_tab.h, but due to BSP's local handler comes before "#include <oal_ioctl_tab.h>" so we know the OALIoCtlDeviceEmulatorHalInitRegistry always get called. In this example, the DeviceEmulator BSP overrides the IOCTL_HAL_INITREGISTRY handler from OALIoCtlHalInitRegistry to OALIoCtlDeviceEmulatorHalInitRegistry by manipulating the g_oalIoCtlTable table. (In some point of view, it is similar to message map in MFC) Please be aware, when you override an IOCTL handler in PQOAL, you may want to clone the original implementation to your BSP and change to meet your need. It is recommended and save you the redundant works but remember to rename the handler function (Just like the DeviceEmulator it changes the name of OALIoCtlHalInitRegistry to OALIoCtlDeviceEmulatorHalInitRegistry). If you don't change the name, linker may not be happy (due to name conflict) and the more important is by using different handler name, you could always redirect the handler back to original one. (It is like the concept of OOP that calling a function in base class; still not so clear? I am goinf to show you soon!) The OALIoCtlDeviceEmulatorHalInitRegistry setups DeviceEmulator specific registry settings and in the end, if everything goes well, it calls the OALIoCtlHalInitRegistry (PLATFORM\COMMON\SRC\COMMON\IOCTL\reginit.c) to do the rest.     if(fOk) {         fOk = OALIoCtlHalInitRegistry(code, pInpBuffer, inpSize, pOutBuffer,             outSize, pOutSize);     } Now you got the picture, whenever you want to override an IOCTL hadnler that is implemented in PQOAL just Clone the handler function to your BSP as a template. Simple name change for the handler function, and a name change in the IOCTL table header file that maps the IOCTL with the function Implement your IOCTL handler and whenever you need to redirect it back just calling the original handler function. It is the standard way of implementing a custom IOCTL and most Microsoft developers prefer. The mapping of IOCTL routine to IOCTL code is platform specific - you control the header file that does that mapping.

    Read the article

  • How to set up a one-man research in the difference between BDD and Waterfall?

    - by Martijn van der Maas
    Earlier, I asked a question about how to measure the quality of a project. The outcome of that question was that the quality of the project can be divided into two parts: Internal quality (code quality, measurable by code quality metrics) External quality (Acceptance test, how well the software meets the requirements) So based on that, I want to set up some research and validate the outcome of the project. The problem is, I will conduct this research on my own, so it's not possible to run the project once in BDD style and the other one in waterfall by myself. It's also not possible to compare BDD and waterfall projects on a larger scale, due to the fact that there are not enough BDD projects that can be measured because of the age of BDD. So, my question is: did anybody face this problem? How could I execute my experiment in such a way that it is of scientific value?

    Read the article

  • Ubuntu Server 12.04 + Wine + Filezilla FTP Server help

    - by Rebecca Joy
    I am not very experienced with non-windows operating systems, so please if you can answer, consider me to be a complete newbie with this. I have a Ubuntu Server 12.04, I installed Wine on it so I could install some familiar programs with GUI on my Ubuntu. I installed Filezilla Server using Wine, that went fine, the server is running, but I cannot find the GUI anywhere. I know it is running because in the winefile, if I execute the filezille server.exe, it says it is already running. However I have not been able to configure anything on the filezilla server because I can't see it anywhere. What am I missing?

    Read the article

  • why not use unmanaged safe code in c#

    - by user613326
    There is an option in c# to execute code unchecked. It's generally not advised to do so, as managed code is much safer and it overcomes a lot of problems. However I am wondering, if you're sure your code won't cause errors, and you know how to handle memory then why (if you like fast code) follow the general advice? I am wondering this since I wrote a program for a video camera, which required some extremely fast bitmap manipulation. I made some fast graphical algorithms myself, and they work excellent on the bitmaps using unmanaged code. Now I wonder in general, if you're sure you don't have memory leaks, or risks of crashes, why not use unmanaged code more often ? PS my background: I kinda rolled into this programming world and I work alone (I do so for a few years) and so I hope this software design question isn't that strange. I don't really have other people out there like a teacher to ask such things.

    Read the article

  • Source Control and SQL Development &ndash; Part 3

    - by Ajarn Mark Caldwell
    In parts one and two of this series, I have been specifically focusing on the latest version of SQL Source Control by Red Gate Software.  But I have been doing source-controlled SQL development for years, long before this product was available, and well before Microsoft came out with Database Projects for Visual Studio.  “So, how does that work?” you may wonder.  Well, let me share some of the details of how we do it where I work… The key to this approach is that everything is done via Transact-SQL script files; either natively written T-SQL, or generated.  My preference is to write all my code by hand, which forces you to become better at your SQL syntax.  But if you really prefer to use the Management Studio GUI to make database changes, you can still do that, and then you use the Generate Scripts feature of the GUI to produce T-SQL scripts afterwards, and store those in your source control system.  You can generate scripts for things like stored procedures and views by right-clicking on the database in the Object Explorer, and Choosing Tasks, Generate Scripts (see figure 1 to the left).  You can also do that for the CREATE scripts for tables, but that does not work when you have a table that is already in production, and you need to make just a simple change, such as adding a new column or index.  In this case, you can use the GUI to make the table changes, and then instead of clicking the Save button, click the Generate Change Script button (). Then, once you have saved the change script, go ahead and execute it on your development database to actually make the change.  I believe that it is important to actually execute the script rather than just click the Save button because this is your first test that your change script is working and you didn’t somehow lose a portion of the change. As you can imagine, all this generating of scripts can get tedious and tempting to skip entirely, so again, I would encourage you to just get in the habit of writing your own Transact-SQL code, and then it is just a matter of remembering to save your work, just like you are in the habit of saving changes to a Word or Excel document before you exit the program. So, now that you have all of these script files, what do you do with them?  Well, we organize ours into folders labeled ChangeScripts, Functions, Views, and StoredProcedures, and those folders are loaded into our source control system.  ChangeScripts contains all of the table and index changes, and anything else that is basically a one-time-only execution.  Of course you want to write your scripts with qualifying logic so that if a script were accidentally run more than once in a database, it would not crash nor corrupt anything; but these scripts are really intended to be run only once in a database. Once you have your initial set of scripts loaded into source control, then making changes, such as altering a stored procedure becomes a simple matter of checking out your CREATE PROCEDURE* script, editing it in SSMS, saving the change, executing the script in order to effect the change in your database, and then checking the script back in to source control.  Of course, this is where the lack of integration for source control systems within SSMS becomes an irritation, because this means that in addition to SSMS, I also have my source control client application running to do the check-out and check-in.  And when you have 800+ procedures like we do, that can be quite tedious to locate the procedure I want to change in source control, check it out, then locate the script file in my working folder, open it in SSMS, do the change, save it, and the go back to source control to check in.  Granted, it is not nearly as burdensome as, say, losing your source code and having to rebuild it from memory, or losing the audit trail that good source control systems provide.  It is worth the effort, and this is how I have been doing development for the last several years. Remember that everything that the SQL Server Management Studio does in modifying your database can also be done in plain Transact-SQL code, and this is what you are storing.  And now I have shown you how you can do it all without spending any extra money.  You already have source control, or can get free, open-source source control systems (almost seems like an oxymoron, doesn’t it) and of course Management Studio is free with your SQL Server database engine software. So, whether you spend the money on tools to make it easier, or not, you now have no excuse for not using source control with your SQL development. * In our current model, the scripts for stored procedures and similar database objects are written with an IF EXISTS…DROP… at the top, followed by the CREATE PROCEDURE… section, and that followed by a section that assigns permissions.  This allows me to run the same script regardless of whether the procedure previously existed in the database.  If the script was only an ALTER PROCEDURE, then it would fail the first time that procedure was deployed to a database, unless you wrote other code to stub it if it did not exist.  There are a few different ways you could organize your scripts for deployment, each with its own trade-offs, but I think it is absolutely critical that whichever way you organize things, you ensure that the same script is run throughout the deployment cycle, and do not allow customizations to creep in between TEST and PROD.  If you do, then you have broken the integrity of your deployment process because what you deployed to PROD was not exactly the same as what was tested in TEST, so you effectively have now released untested code into PROD.

    Read the article

  • Updating a database connection password using a script

    - by Tim Dexter
    An interesting customer requirement that I thought was worthy of sharing today. Thanks to James for the requirement and Bryan for the proposed solution and me for testing the solution and proving it works :0) A customers implementation of Sarbanes Oxley requires them to change all database account passwords every 90 days. This is scripted leveraging shell scripts today for most of their environments. But how can they manage the BI Publisher connections? Now, the customer is running 11g and therefore using weblogic on the middle tier, which is the first clue to Bryans proposed solution. To paraphrase and embellish Bryan's solution a little; why not use a JNDI connection from BIP to the database. Then employ the web logic scripting engine to make updates to the JNDI as needed? BIP is completely uninvolved and with a little 'timing' users will be completely unaware of the password updates i.e. change the password when reports are not being executed. Perfect! James immediately tracked down the WLST script that could be used here, http://middlewaremagic.com/weblogic/?p=4261 (thanks Ravish) Now it was just a case of testing the theory. Some steps: Create the JNDI connection in WLS Create the JNDI connection in BI Publisher pointing to the WLS connection Build new data models using or re-point data sources to use the JNDI connection. Create the WLST script to update the WLS JNDI password as needed. Test! Some details. Creating the JNDI connection in web logic is pretty straightforward. Log into hte console and look for Data Sources under the Services section of the home page and click it Click New >> Generic Datasource Give the connection a name. For the JNDI name, prefix it with 'jdbc/' so I have 'jdbc/localdb' - this name is important you'll need it on the BIP side. Select your db type - this will influence the drivers and information needed on the next page. Being a company man, Im using an Oracle db. Click Next Select the driver of choice, theres lots I know, you can read about them I just chose 'Oracle's Driver (Thin) for Instance connections; Versions 9.0.1 and later' Click Next >> Next Fill out the db name (SID), server, port, username to connect and password >> Next Test the config to ensure you can connect. >> Next Now you need to deploy the connection to your BI server, select it and click Next. You're done with the JNDI config. Creating the JNDI connection on the Publisher side is covered here. Just remember to the connection name you created in WLS e.g. 'jdbc/localdb' Not gonna tell you how to do this, go read the user guide :0) Suffice to say, it works. This requires a little reading around the subject to understand the scripting engine and how to execute scripts. Nicely covered here. However a bit of googlin' and I found an even easier way of running the script. ${ServerHome}/common/bin/wlst.sh updatepwd.py Where updatepwd.py is my script file, it can be in another directory. As part of the wlst.sh script your environment is set up for you so its very simple to execute. The nitty gritty: Need to take Ravish's script above and create a file with a .py extension. Its going to need some modification, as he explains on the web page, to make it work in your environment. I played around with it for a while but kept running into errors. The script as is, tries to loop through all of your connections and modify the user and passwords for each. Not quite what we are looking for. Remember our requirement is to just update the password for a given connection. I also found another issue with the script. WLS 10.x does not allow updates to passwords using clear type ie un-encrypted text while the server is in production mode. Its a bit much to set it back to developer mode bounce it, change the passwords and then bounce and then change back to production and bounce again. After lots of messing about I finally came up with the following: ############################################################################# # # Update password for JNDI connections # ############################################################################# print("*** Trying to Connect.... *****") connect('weblogic','welcome1','t3://localhost:7001') print("*** Connected *****") edit() startEdit() print ("*** Encrypt the password ***") en = encrypt('hr') print "Encrypted pwd: ", en print ("*** Changing pwd for LocalDB ***") dsName = 'LocalDB' print 'Changing Password for DataSource ', dsName cd('/JDBCSystemResources/'+dsName+'/JDBCResource/'+dsName+'/JDBCDriverParams/'+dsName) set('PasswordEncrypted',en) save() activate() Its pretty simple and you can expand on it to loop through the data sources and change each as needed. I have hardcoded the password into the file but you can pass it as a parameter as needed using the properties file method. Im not going to get into the detail of that here but its covered with an example here. Couple of points to note: 1. The change to the password requires a server bounce to get the changes picked up. You can add that to the shell script you will use to call the script above. 2. The script above needs to be run from the MW_HOME\user_projects\domains\bifoundation_domain directory to get the encryption libraries set correctly. My command to run the whole script was: d:\oracle\bi_mw\wlserver_10.3\common\bin\wlst.cmd updatepwd.py - where wlst.cmd is the scripting command line and updatepwd.py was my update password script above. I have not quite spoon fed everything you need to make it a robust script but at least you know you can do it and you can work out the rest I think :0)

    Read the article

  • Unable to add host running ubuntu for nagios monitoring?

    - by karthick87
    I am unable to add ubuntu server in nagios monitoring. I am getting "CHECK_NRPE: Socket timeout after 40 seconds." error for few services "CPU Load, Cron File Check, Current Users, Disk Check, NTP Daemon, Time Check, Total Processes, Zombie Processes". Please find the snapshot for the same below, Details: Installed nrpe plugin in ubuntu host. On running the below command from remote host running ubuntu (not nagios server) am getting the following output, root@ubuntu-cacher:~# /usr/local/nagios/libexec/check_nrpe -H localhost NRPE v2.13 But in nagios server i am getting "CHECK_NRPE: Socket timeout after 40 seconds." error. Additional Information: Am running nrpe under xinetd, when i execute the following command i dont get any output, root@ubuntu-cacher:~# netstat -at | grep nrpe But getting the following output when checking, root@ubuntu-cacher:~# netstat -ant|grep 5666 tcp 0 0 0.0.0.0:5666 0.0.0.0:* LISTEN tcp 0 0 172.29.*.*:5666 172.29.*.*:33693 ESTABLISHED tcp 0 0 172.29.*.*:5666 172.29.*.*:33692 ESTABLISHED

    Read the article

  • Broken keyboard shortcuts

    - by c089
    When I freshly installed maverick on my new notebook, I set up my keyboard shortcuts like this: Switch to WS 1 = Mod4+1, Move Window to WS 1 = Mod4+Shift+1, Switch to WS 2 = Mod4+2 and so on (Mod4 being the "Windows" key). But now the three-key combinations (i.e. the ones I use for "move to...") stopped working. When I go to keyboard preferences, I still see them and I can even change them to a different combination and then again to the desired one - but they won't execute the window movement afterwards :/ Any suggestions how to fix this?

    Read the article

  • Database Owner Conundrum

    - by Johnm
    Have you ever restored a database from a production environment on Server A into a development environment on Server B and had some items, such as Service Broker, mysteriously cease functioning? You might want to consider reviewing the database owner property of the database. The Scenario Recently, I was developing some messaging functionality that utilized the Service Broker feature of SQL Server in a development environment. Within the instance of the development environment resided two databases: One was a restored version of a production database that we will call "RestoreDB". The second database was a brand new database that has yet to exist in the production environment that we will call "DevDB". The goal is to setup a communication path between RestoreDB and DevDB that will later be implemented into the production database. After implementing all of the Service Broker objects that are required to communicate within a database as well as between two databases on the same instance I found myself a bit confounded. My testing was showing that the communication was successful when it was occurring internally within DevDB; but the communication between RestoreDB and DevDB did not appear to be working. Profiler to the rescue After carefully reviewing my code for any misspellings, missing commas or any other minor items that might be a syntactical cause of failure, I decided to launch Profiler to aid in the troubleshooting. After simulating the cross database messaging, I noticed the following error appearing in Profiler: An exception occurred while enqueueing a message in the target queue. Error: 33009, State: 2. The database owner SID recorded in the master database differs from the database owner SID recorded in database '[Database Name Here]'. You should correct this situation by resetting the owner of database '[Database Name Here]' using the ALTER AUTHORIZATION statement. Now, this error message is a helpful one. Not only does it identify the issue in plain language, it also provides a potential solution. An execution of the following query that utilizes the catalog view sys.transmission_queue revealed the same error message for each communication attempt: SELECT     * FROM        sys.transmission_queue; Seeing the situation as a learning opportunity I dove a bit deeper. Reviewing the database properties  The owner of a specific database can be easily viewed by right-clicking the database in SQL Server Management Studio and selecting the "properties" option. The owner is listed on the "General" page of the properties screen. In my scenario, the database in the production server was created by Frank the DBA; therefore his server login appeared as the owner: "ServerName\Frank". While this is interesting information, it certainly doesn't tell me much in regard to the SID (security identifier) and its existence, or lack thereof, in the master database as the error suggested. I pulled together the following query to gather more interesting information: SELECT     a.name     , a.owner_sid     , b.sid     , b.name     , b.type_desc FROM        master.sys.databases a     LEFT OUTER JOIN master.sys.server_principals b         ON a.owner_sid = b.sid WHERE     a.name not in ('master','tempdb','model','msdb'); This query also helped identify how many other user databases in the instance were experiencing the same issue. In this scenario, I saw that there were no matching SIDs in server_principals to the owner SID for my database. What login should be used as the database owner instead of Frank's? The system stored procedure sp_helplogins will provide a list of the valid logins that can be used. Here is an example of its use, revealing all available logins: EXEC sp_helplogins;  Fixing a hole The error message stated that the recommended solution was to execute the ALTER AUTHORIZATION statement. The full statement for this scenario would appear as follows: ALTER AUTHORIZATION ON DATABASE:: [Database Name Here] TO [Login Name]; Another option is to execute the following statement using the sp_changedbowner system stored procedure; but please keep in mind that this stored procedure has been deprecated and will likely disappear in future versions of SQL Server: EXEC dbo.sp_changedbowner @loginname = [Login Name]; .And They Lived Happily Ever After Upon changing the database owner to an existing login and simulating the inner and cross database messaging the errors have ceased. More importantly, all messages sent through this feature now successfully complete their journey. I have added the ownership change to my restoration script for the development environment.

    Read the article

  • How does throwing an ArgumentNullException help?

    - by Scott Whitlock
    Let's say I have a method: public void DoSomething(ISomeInterface someObject) { if(someObject == null) throw new ArgumentNullException("someObject"); someObject.DoThisOrThat(); } I've been trained to believe that throwing the ArgumentNullException is "correct" but an "Object reference not set to an instance of an object" error means I have a bug. Why? I know that if I was caching the reference to someObject and using it later, then it's better to check for nullity when passed in, and fail early. However, if I'm dereferencing it on the next line, why are we supposed to do the check? It's going to throw an exception one way or the other. Edit: It just occurred to me... does the fear of the dereferenced null come from a language like C++ that doesn't check for you (i.e. it just tries to execute some method at memory location zero + method offset)?

    Read the article

  • Calling MSSQL stored procedure from Zend Controller ? Any other approaches?

    - by Bhavin Rana
    MSSQL and DB, Zend as PHP Framework, I am using this way to call SP with I/P Parameters and to get O/p Parameters. It seems I am writing SQL code in PHP. Any other good approaches? $str1 = "DECLARE @Msgvar varchar(100); DECLARE @last_id int; exec DispatchProduct_m_Ins $DispatchChallanId,'$FRUNo',$QTY,$Rate,$Amount, ".$this->cmpId.",".$this->aspId.",".$this->usrId.",@Msg = @Msgvar OUTPUT,@LAST_ID = @last_id OUTPUT; SELECT @Msgvar AS N'@Msg',@last_id AS '@LAST_ID'; ";//Calling SP $stmt = $db->prepare($str1); $stmt->execute(); $rsDispProd = $stmt->fetchAll(); $DispatchProductId = $rsDispProd[0]["@LAST_ID"];//get last ins ID as O/p Parameter

    Read the article

  • T-SQL User-Defined Functions: the good, the bad, and the ugly (part 1)

    - by Hugo Kornelis
    So you thought that encapsulating code in user-defined functions for easy reuse is a good idea? Think again! SQL Server supports three types of user-defined functions. Only one of them qualifies as good. The other two – well, the title says it all, doesn’t it? The bad: scalar functions A scalar user-defined function (UDF) is very much like a stored procedure, except that it always returns a single value of a predefined data type – and because of that property, it isn’t invoked with an EXECUTE statement,...(read more)

    Read the article

  • Can I force window to open on top of other windows when opened by keyboard shortcut?

    - by Rasmus
    I use SpaceFM as my primary file manager on Ubuntu. I typically open folder directly by keyboard shortcuts, so, e.g. Ctrl+Super+W opens my Work folder. Specifically, I use execute the command spacefm -w /home/rasmus/Work/ by the above shortcut, with the -w ensuring that SpaceFM opens a new window. However, this new window is not always open on top of the last active window on the workspace. This is rather annoying, as it means I sometimes have to "dig" for the newly opened window. So, my question is: Is there something additional I can add to the executed command that will ensure that the fresh window is opened on top? Alternative solutions to the same effect are welcome.

    Read the article

< Previous Page | 103 104 105 106 107 108 109 110 111 112 113 114  | Next Page >