Search Results

Search found 13288 results on 532 pages for 'high speed'.

Page 113/532 | < Previous Page | 109 110 111 112 113 114 115 116 117 118 119 120  | Next Page >

  • C# - periodic data reading and Thread.Sleep()

    - by CaldonCZE
    Hello, my C# application reads data from special USB device. The data are read as so-called "messages", each of them having 24 bytes. The amount of messages that must be read per second may differ (maximal frequency is quite high, about 700 messages per second), but the application must read them all. The only way to read the messages is by calling function "ReadMessage", that returns one message read from the device. The function is from external DLL and I cannot modify it. My solution: I've got a seperate thread, that is running all the time during the program run and it's only job is to read the messages in cycle. The received messages are then processed in main application thread. The function executed in the "reading thread" is the following: private void ReadingThreadFunction() { int cycleCount; try { while (this.keepReceivingMessages) { cycleCount++; TRxMsg receivedMessage; ReadMessage(devHandle, out receivedMessage); //...do something with the message... } } catch { //... catch exception if reading failed... } } This solution works fine and all messages are correctly received. However, the application consumes too much resources, the CPU of my computer runs at more than 80%. Therefore I'd like to reduce it. Thanks to the "cycleCount" variable I know that the "cycling speed" of the thread is about 40 000 cycles per second. This is unnecessarily too much, since I need to receive maximum 700 messagges/sec. (and the device has buffer for about 100 messages, so the cycle speed can be even a little lower) I tried to reduce the cycle speed by suspending the thread for 1 ms by Thread.Sleep(1); command. Of course, this didn't work and the cycle speed became about 70 cycles/second which was not enough to read all messages. I know that this attempt was silly, that putting the thread to sleep and then waking him up takes much longer than 1 ms. However, I don't know what else to do: Is there some other way how to slow the thread execution down (to reduce CPU consumption) other than Thread.Sleep? Or am I completely wrong and should I use something different for this task instead of Thread, maybe Threading.Timer or ThreadPool? Thanks a lot in advance for all suggestions. This is my first question here and I'm a beginner at using threads, so please excuse me if it's not clear enough.

    Read the article

  • how to check how many bits in a byte array?

    - by newandfresh
    Im creating a download speed test, and im downloading a 800megabit file to a Byte[] in a memory stream with webClient.DownloadDataAsync(new Uri(link), memStreamArray); How can i check how many bits are in the memStreamArray while downloading? I need this so i can do a calculation on size / time to get the speed in realtime. Im planing on performing this calculation in the webClient.DownloadProgressChanged event.

    Read the article

  • mvc partial views loses track of the images folder when using jquery

    - by jvelez
    This is what I have and it works: $(function(){ $('.slide-out-div').tabSlideOut({ tabHandle: '.handle', //class of the element that will become your tab pathToTabImage: 'http://mhmiisdev2/images/contact_tab.gif', //path to the image for the tab //Optionally can be set using css imageHeight: '122px', //height of tab image //Optionally can be set using css imageWidth: '40px', //width of tab image //Optionally can be set using css tabLocation: 'right', //side of screen where tab lives, top, right, bottom, or left speed: 300, //speed of animation action: 'click', //options: 'click' or 'hover', action to trigger animation topPos: '200px', //position from the top/ use if tabLocation is left or right leftPos: '20px', //position from left/ use if tabLocation is bottom or top fixedPosition: true //options: true makes it stick(fixed position) on scroll }); }); This is what I want and it doesnt work when I change from one controller to another controller. NOTICE THE IMAGE PATH IS NOT ABSOLUTE $(function(){ $('.slide-out-div').tabSlideOut({ tabHandle: '.handle', //class of the element that will become your tab pathToTabImage: '/images/contact_tab.gif', //path to the image for the tab //Optionally can be set using css imageHeight: '122px', //height of tab image //Optionally can be set using css imageWidth: '40px', //width of tab image //Optionally can be set using css tabLocation: 'right', //side of screen where tab lives, top, right, bottom, or left speed: 300, //speed of animation action: 'click', //options: 'click' or 'hover', action to trigger animation topPos: '200px', //position from the top/ use if tabLocation is left or right leftPos: '20px', //position from left/ use if tabLocation is bottom or top fixedPosition: true //options: true makes it stick(fixed position) on scroll }); }); the html for completeness.... <div class="slide-out-div"> <a class="handle" href="http://link-for-non-js-users.html">Content</a> <h3>Medical Variance Reports</h3> <div> <ul> <li><a href="http://mhmssrs2/Reports/Pages/Report.aspx?" target="_blank">Individual Medicines</a></li> </ul> </div> </div> I suspect somehow pathToTabImage: /images/contact_tab.gif' loses its context when browsing throught controllers. Help me understand...

    Read the article

  • matlab's fortran's format equivalents

    - by ldigas
    What would be matlab's equivalent of write(1,'("Speed, resistance, power",3f8.2)')(a(i),i=1,3) I've tried a = [10. 20. 200.] fprintf(unit1,'a = 3%8.1e',a) but I'm still having trouble with it (the whole matlab output formatting thing). Edit for Kenny: for the values of a as given above, it would give (in a new row): Speed, resistance, power 10.00 20.00 200.00

    Read the article

  • How I can check gzip decoding time in the web browser?

    - by user293421
    I want to check the performance of the gzip decoding speed in a web browser. In the Java or c#, we can easily check the gzip decoding time. But I can not measure the decoding time in the web browser. plz help me. I want to check some decoding speed of gzipped html files. With JavaScript can I measure the performance.

    Read the article

  • Why use one dimensional array instead of a two dimensional arrray?

    - by user3869145
    I was doing some work handling a lot of information and my partner told me that I was using too many matrices to manipulate the variables of the problem. The idea was to use one dimension arrays int a[] instead of the 2 dimensional arrays int b[][], to save memory and processing speed of the algorithm. How certain is that this change will accelerate the speed of execution or compilation of my code in c ++?

    Read the article

  • Curl CONNECTION OPTIONS in C++

    - by cinek1lol
    HI I'd like to know how to check out the speed of a file being uploaded in real time using the curl library in c++. This is what I have written: curl_easy_getinfo(curl,CURLINFO_SPEED_UPLOAD,&c); But the manual says that it shows average speed, but even this doesn't seem to work with me, because I can only see a 0. There is one more thing: How to set an upload limit that works, because if I write this: curl_easy_setopt(curl, CURLOPT_MAX_SEND_SPEED_LARGE, 100); I get an error 502 message

    Read the article

  • BIOS upgrade lowers CPU temperature

    - by N.N.
    Setup I've got a system with an Asus P8Z68-V PRO motherboard and an Intel Core i7-2600K CPU running at stock speed (no overlocking) which I cool with a Noctua NH-U12P. On the heatsink I've got the two included fans connected via the included Low-Noise Adapters (L.N.A.) 1100 RPM, 16.9 dB(A). In the BIOS settings I've set the CPU and chassis fan profile to silent. Issue Yesterday I upgraded from BIOS version 0501 to 0606. After the upgrade I checked the temperatures in the BIOS monitor and was surprised to see that the CPU temperature was slightly ~30°C. Before the upgrade the CPU temperature was ~50°C with the same BIOS settings (see the following heading for details on temperatures). How can this be? It seems a bit odd that a BIOS upgrade can lower the CPU temperature by 20°C and it also seems odd that the CPU temperature is lower than the chassis temperature. Temperatures When I've checked temperatures the room temperature has been ~23°C. I haven't changed the placement of the computer nor the hardware or cooling setup between BIOS versions. BIOS version 0501 BIOS monitor: CPU: ~50°C Chassis: ~33°C I haven't got any temperature measures from lm-sensors or the like for version 0501 because I only discovered the issue after upgrading to version 0606 and the BIOS updater utility won't let me downgrade to version 0501 (it says "outdated image" when I try to load version 0501). BIOS version 0606 BIOS monitor: CPU: ~30°C Chassis: ~33°C lm-sensors in Ubuntu 11.04 Desktop 64-bit (sudo sensors after an uptime of 4 h 52 min and a load average of 0.22, 0.18, 0.15): coretemp-isa-0000 Adapter: ISA adapter Core 0: +32.0°C (high = +80.0°C, crit = +98.0°C) coretemp-isa-0001 Adapter: ISA adapter Core 1: +35.0°C (high = +80.0°C, crit = +98.0°C) coretemp-isa-0002 Adapter: ISA adapter Core 2: +29.0°C (high = +80.0°C, crit = +98.0°C) coretemp-isa-0003 Adapter: ISA adapter Core 3: +36.0°C (high = +80.0°C, crit = +98.0°C) The BIOS monitor temperatures was checked directly after the lm-sensors temperatures was checked. BIOS version 0706, 0801, 1101 and 3203 I get the same kind of temperatures both in the BIOS monitor and with lm-sensors in BIOS version 0706, 0801, 1101 and 3203 as in 0606. Information from Asus The 0606 changelog mentions nothing explicitly about CPU temperature (but item 3., as indicated by sidran32, might affect temperatures): P8Z68-V PRO 0606 BIOS with IRST 10.6.0.1002 Enable the support of Intel Rapid Storage Technology version 10.6.0.1002 Release Improve DRAM compatibility Improve System stability Improve compatibility with some Raid card model Increase IGD share memory size to 512MB However the following FAQ might give a hint: FAQs I find that the CPU temperature reading in BIOS is about 10~20 degrees centigrade hotter than the reading in OS. Is it normal? Page Tools Solution That is normal as BIOS does not send idle command to the CPU, making most of the power saving features useless. You should be getting similar reading if you disable EIST/C1E/CPU C3 Report/CPU C6 Report in BIOS.

    Read the article

  • How to change cpufreq settings in Kubuntu

    - by Mr Woody
    I have been using Kubuntu, and I would like to change the cpufreq settings. My understanding is that there is no applet for that, and I would have to do it with a script. So I run a command like this: sudo cpufreq-set -g userspace -c 0 -d 800Mhz -u 1200Mhz and when I type cpufreq-info, I get cpufrequtils 007: cpufreq-info (C) Dominik Brodowski 2004-2009 Report errors and bugs to [email protected], please. analyzing CPU 0: driver: acpi-cpufreq CPUs which run at the same hardware frequency: 0 1 CPUs which need to have their frequency coordinated by software: 0 maximum transition latency: 10.0 us. hardware limits: 800 MHz - 2.50 GHz available frequency steps: 2.50 GHz, 2.50 GHz, 2.00 GHz, 1.60 GHz, 1.20 GHz, 800 MHz available cpufreq governors: conservative, ondemand, userspace, powersave, performance current policy: frequency should be within 800 MHz and 1.20 GHz. The governor "userspace" may decide which speed to use within this range. current CPU frequency is 1.20 GHz. cpufreq stats: 2.50 GHz:70.06%, 2.50 GHz:0.97%, 2.00 GHz:4.85%, 1.60 GHz:0.35%, 1.20 GHz:2.89%, 800 MHz:20.88% (193873) analyzing CPU 1: driver: acpi-cpufreq CPUs which run at the same hardware frequency: 0 1 CPUs which need to have their frequency coordinated by software: 1 maximum transition latency: 10.0 us. hardware limits: 800 MHz - 2.50 GHz available frequency steps: 2.50 GHz, 2.50 GHz, 2.00 GHz, 1.60 GHz, 1.20 GHz, 800 MHz available cpufreq governors: conservative, ondemand, userspace, powersave, performance current policy: frequency should be within 2.00 GHz and 2.00 GHz. The governor "performance" may decide which speed to use within this range. current CPU frequency is 2.00 GHz. cpufreq stats: 2.50 GHz:83.43%, 2.50 GHz:1.03%, 2.00 GHz:4.28%, 1.60 GHz:0.01%, 1.20 GHz:1.74%, 800 MHz:9.50% (3208) which shows that everything worked well (on cpu 0). The problem is that if I run cpufreq-info again after few minutes I get cpufrequtils 007: cpufreq-info (C) Dominik Brodowski 2004-2009 Report errors and bugs to [email protected], please. analyzing CPU 0: driver: acpi-cpufreq CPUs which run at the same hardware frequency: 0 1 CPUs which need to have their frequency coordinated by software: 0 maximum transition latency: 10.0 us. hardware limits: 800 MHz - 2.50 GHz available frequency steps: 2.50 GHz, 2.50 GHz, 2.00 GHz, 1.60 GHz, 1.20 GHz, 800 MHz available cpufreq governors: conservative, ondemand, userspace, powersave, performance current policy: frequency should be within 800 MHz and 800 MHz. The governor "performance" may decide which speed to use within this range. current CPU frequency is 800 MHz. cpufreq stats: 2.50 GHz:69.73%, 2.50 GHz:0.97%, 2.00 GHz:4.83%, 1.60 GHz:0.35%, 1.20 GHz:2.92%, 800 MHz:21.20% (193880) analyzing CPU 1: driver: acpi-cpufreq CPUs which run at the same hardware frequency: 0 1 CPUs which need to have their frequency coordinated by software: 1 maximum transition latency: 10.0 us. hardware limits: 800 MHz - 2.50 GHz available frequency steps: 2.50 GHz, 2.50 GHz, 2.00 GHz, 1.60 GHz, 1.20 GHz, 800 MHz available cpufreq governors: conservative, ondemand, userspace, powersave, performance current policy: frequency should be within 800 MHz and 800 MHz. The governor "performance" may decide which speed to use within this range. current CPU frequency is 800 MHz. cpufreq stats: 2.50 GHz:82.94%, 2.50 GHz:1.03%, 2.00 GHz:4.33%, 1.60 GHz:0.01%, 1.20 GHz:1.73%, 800 MHz:9.96% (3215) so it looks like some other process changed the settings. Does anyone know how to fix this? I also tried many different settings, but I get similar behavior.

    Read the article

  • Cisco ASA not forwarding traffic from one interface to another

    - by Antoine Benkemoun
    Hello ServerFault, I am needing help in the configuration process of my Cisco ASA 5510. I have set up 4 Cisco ASA interconnected together via a big LAN. Each Cisco ASA has 3 or 4 LANs attached to them. The IP routing part is taken care of by OSPF. My problem is on another level. A computer connected to one of the LANs attached to an ASA has no problem communicating with the outside world. The outside world being anything "after" the ASA. My problem is that I am completely unable to have them communicate with another LAN connected to the same ASA. To rephrase this, I am unable to send traffic from one interface of a given ASA to another interface of the same ASA. My configuration is the following : ! hostname Fuji ! interface Ethernet0/0 speed 100 duplex full nameif outside security-level 0 ip address 10.0.0.2 255.255.255.0 no shutdown ! interface Ethernet0/1 speed 100 duplex full nameif cs4 no shutdown security-level 100 ip address 10.1.4.1 255.255.255.0 ! interface Ethernet0/2 speed 100 duplex full no shutdown ! interface Ethernet0/2.15 vlan 15 nameif cs5 security-level 100 ip address 10.1.5.1 255.255.255.0 ! interface Ethernet0/2.16 vlan 16 nameif cs6 security-level 100 ip address 10.1.6.1 255.255.255.0 ! interface Management0/0 speed 100 duplex full nameif management security-level 100 ip address 10.6.0.252 255.255.255.0 ! access-list nat_cs4 extended permit ip 10.1.4.0 255.255.255.0 any access-list acl_cs4 extended permit ip 10.1.4.0 255.255.255.0 any access-list nat_cs5 extended permit ip 10.1.5.0 255.255.255.0 any access-list acl_cs5 extended permit ip 10.1.5.0 255.255.255.0 any access-list nat_cs6 extended permit ip 10.1.6.0 255.255.255.0 any access-list acl_cs6 extended permit ip 10.1.6.0 255.255.255.0 any ! access-list nat_outside extended permit ip any any access-list acl_outside extended permit ip any 10.1.4.0 255.255.255.0 access-list acl_outside extended permit ip any 10.1.5.0 255.255.255.0 access-list acl_outside extended permit ip any 10.1.6.0 255.255.255.0 ! nat (outside) 0 access-list nat_outside nat (cs4) 0 access-list nat_cs4 nat (cs5) 0 access-list nat_cs5 nat (cs6) 0 access-list nat_cs6 ! static (outside,cs4) 0.0.0.0 0.0.0.0 netmask 0.0.0.0 static (outside,cs5) 0.0.0.0 0.0.0.0 netmask 0.0.0.0 static (outside,cs6) 0.0.0.0 0.0.0.0 netmask 0.0.0.0 ! static (cs4,outside) 10.1.4.0 10.1.4.0 netmask 255.255.255.0 static (cs4,cs5) 10.1.4.0 10.1.4.0 netmask 255.255.255.0 static (cs4,cs6) 10.1.4.0 10.1.4.0 netmask 255.255.255.0 ! static (cs5,outside) 10.1.5.0 10.1.5.0 netmask 255.255.255.0 static (cs5,cs4) 10.1.5.0 10.1.5.0 netmask 255.255.255.0 static (cs5,cs6) 10.1.5.0 10.1.5.0 netmask 255.255.255.0 ! static (cs6,outside) 10.1.6.0 10.1.6.0 netmask 255.255.255.0 static (cs6,cs4) 10.1.6.0 10.1.6.0 netmask 255.255.255.0 static (cs6,cs5) 10.1.6.0 10.1.6.0 netmask 255.255.255.0 ! access-group acl_outside in interface outside access-group acl_cs4 in interface cs4 access-group acl_cs5 in interface cs5 access-group acl_cs6 in interface cs6 ! router ospf 1 network 10.0.0.0 255.255.255.0 area 1 network 10.1.4.0 255.255.255.0 area 1 network 10.1.5.0 255.255.255.0 area 1 network 10.1.6.0 255.255.255.0 area 1 log-adj-changes ! There is nothing really complicated in this configuration. It just NATs from one interface to another and that's it. I have tried enabling same-security-traffic permit inter-interface but that doesn't help. I therefore must be missing something a little bit more complicated. Does anyone know why I cannot foward traffic from one interface to another ? Thank you in advance for your help, Antoine

    Read the article

  • Weird screeching sounds coming from computer

    - by EGHDK
    My computer makes a high pitched whine noise that initially was coming from my SSD, but now I recently installed more ram into my laptop and it makes a new sounds. I don't want my ram or SSD to die on me. Are there any tests to test both of these? Again, these are really high pitched whine(y) sounds that you wouldn't hear normally, but when I'm home alone and it's silent, the noise sounds as loud as can be.

    Read the article

  • Monitoring the Server load In Windows NT and triggering a scheduled task

    - by Gnanesh
    Hi, I am having the following problem. I am running a Windows NT server. I need to monitor the server utilization continuously (automated process) and need to know if the server load is high. And if it high I need to trigger a scheduled task. Can we write a VB script in order to do this? Can someone please help me? Kindly let me know in case you require more info on this Thanks

    Read the article

  • Is this a HPC or HA mySQL cluster?

    - by Louise Hoffman
    Can someone tell me if this is a High Performance Compute or High Available mySQL cluster? There is a picture of the setup. This is part of the config.ini they talk about [ndbd default] NoOfReplicas=2 # Number of replicas Is it correct understood that NoOfReplicas determines if I have a HPC or a HA cluster?

    Read the article

  • Bonding: works only for download

    - by Crazy_Bash
    I would like to install bonding with 4 links with mode 4. but only "download/receiving" works with bondig. for transmitting the system chooses one link. ifconfig bond0 Link encap:Ethernet HWaddr 90:E2:BA:0F:76:B4 inet addr:ip Bcast:ip Mask:255.255.255.248 inet6 addr: fe80::92e2:baff:fe0f:76b4/64 Scope:Link UP BROADCAST RUNNING MASTER MULTICAST MTU:1500 Metric:1 RX packets:239187413 errors:0 dropped:10944 overruns:0 frame:0 TX packets:536902370 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:14688536197 (13.6 GiB) TX bytes:799521192901 (744.6 GiB) eth2 Link encap:Ethernet HWaddr 90:E2:BA:0F:76:B4 UP BROADCAST RUNNING SLAVE MULTICAST MTU:1500 Metric:1 RX packets:54969488 errors:0 dropped:0 overruns:0 frame:0 TX packets:2537 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:3374778591 (3.1 GiB) TX bytes:314290 (306.9 KiB) eth3 Link encap:Ethernet HWaddr 90:E2:BA:0F:76:B4 UP BROADCAST RUNNING SLAVE MULTICAST MTU:1500 Metric:1 RX packets:64935805 errors:0 dropped:1 overruns:0 frame:0 TX packets:2532 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:3993499746 (3.7 GiB) TX bytes:313968 (306.6 KiB) eth4 Link encap:Ethernet HWaddr 90:E2:BA:0F:76:B4 UP BROADCAST RUNNING SLAVE MULTICAST MTU:1500 Metric:1 RX packets:57352105 errors:0 dropped:2 overruns:0 frame:0 TX packets:536894778 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:3524236530 (3.2 GiB) TX bytes:799520265627 (744.6 GiB) eth5 Link encap:Ethernet HWaddr 90:E2:BA:0F:76:B4 UP BROADCAST RUNNING SLAVE MULTICAST MTU:1500 Metric:1 RX packets:61930025 errors:0 dropped:3 overruns:0 frame:0 TX packets:2540 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:3796021948 (3.5 GiB) TX bytes:314274 (306.9 KiB) lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:16436 Metric:1 RX packets:62 errors:0 dropped:0 overruns:0 frame:0 TX packets:62 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:5320 (5.1 KiB) TX bytes:5320 (5.1 KiB) those are my configs: DEVICE="eth2" BOOTPROTO="none" MASTER=bond0 SLAVE=yes USERCTL=no NM_CONTROLLED="no" ONBOOT="yes" DEVICE="eth3" BOOTPROTO="none" MASTER=bond0 SLAVE=yes USERCTL=no NM_CONTROLLED="no" ONBOOT="yes" DEVICE="eth4" BOOTPROTO="none" MASTER=bond0 SLAVE=yes USERCTL=no NM_CONTROLLED="no" ONBOOT="yes" DEVICE="eth5" BOOTPROTO="none" MASTER=bond0 SLAVE=yes USERCTL=no NM_CONTROLLED="no" ONBOOT="yes" DEVICE=bond0 IPADDR=<ip> BROADCAST=<ip> NETWORK=<ip> GATEWAY=<ip> NETMASK=<ip> USERCTL=no BOOTPROTO=none ONBOOT=yes NM_CONTROLLED=no cat /proc/net/bonding/bond0 Ethernet Channel Bonding Driver: v3.7.1 (April 27, 2011) Bonding Mode: IEEE 802.3ad Dynamic link aggregation Transmit Hash Policy: layer2 (0) MII Status: up MII Polling Interval (ms): 100 Up Delay (ms): 0 Down Delay (ms): 0 802.3ad info LACP rate: slow Aggregator selection policy (ad_select): stable Active Aggregator Info: Aggregator ID: 1 Number of ports: 4 Actor Key: 17 Partner Key: 11 Partner Mac Address: 00:24:51:12:63:00 Slave Interface: eth2 MII Status: up Speed: 1000 Mbps Duplex: full Link Failure Count: 0 Permanent HW addr: 90:e2:ba:0f:76:b4 Aggregator ID: 1 Slave queue ID: 0 Slave Interface: eth3 MII Status: up Speed: 1000 Mbps Duplex: full Link Failure Count: 0 Permanent HW addr: 90:e2:ba:0f:76:b5 Aggregator ID: 1 Slave queue ID: 0 Slave Interface: eth4 MII Status: up Speed: 1000 Mbps Duplex: full Link Failure Count: 0 Permanent HW addr: 90:e2:ba:0f:76:b6 Aggregator ID: 1 Slave queue ID: 0 Slave Interface: eth5 MII Status: up Speed: 1000 Mbps Duplex: full Link Failure Count: 0 Permanent HW addr: 90:e2:ba:0f:76:b7 Aggregator ID: 1 Slave queue ID: 0 /etc/modprobe.d/bonding.conf alias bond0 bonding options bond0 mode=4 miimon=100 updelay=200 #downdelay=200 xmit_hash_policy=layer3+4 lacp_rate=1 Linux: Linux 3.0.0+ #1 SMP Fri Oct 26 07:55:47 EEST 2012 x86_64 x86_64 x86_64 GNU/Linux what i've tried: downdelay=200 xmit_hash_policy=layer3+4 lacp_rate=1 mode 6

    Read the article

  • Why should I use Amazon Route 53 over my registrar's DNS servers?

    - by Abtin Forouzandeh
    I am building a site that I anticipate will have high usage. Currently, my registrar (GoDaddy) is handling DNS. However, Amazon's Route 53 looks interesting. They promise high speed and offer globally distributed DNS servers and a programmable interface. While GoDaddy doesn't offer a programmable interface, I assume their servers are geographically distributed as well. What are the main reasons I should opt to use Amazon Route 53 over free registrar-based DNS?

    Read the article

  • How can order of IP addresses issued be controlled?

    - by warren
    Every home router I've setup/used issues addresses from low to high. However, dhcpd from the Internet Systems Consortium seems to issue addresses in reverse order - ie, high to low. Is there a way to change this so that addresses are issued starting at the bottom of the range, and progress higher?

    Read the article

  • Linux software RAID6: rebuild slow

    - by Ole Tange
    I am trying to find the bottleneck in the rebuilding of a software raid6. ## Pause rebuilding when measuring raw I/O performance # echo 1 > /proc/sys/dev/raid/speed_limit_min # echo 1 > /proc/sys/dev/raid/speed_limit_max ## Drop caches so that does not interfere with measuring # sync ; echo 3 | tee /proc/sys/vm/drop_caches >/dev/null # time parallel -j0 "dd if=/dev/{} bs=256k count=4000 | cat >/dev/null" ::: sdbd sdbc sdbf sdbm sdbl sdbk sdbe sdbj sdbh sdbg 4000+0 records in 4000+0 records out 1048576000 bytes (1.0 GB) copied, 7.30336 s, 144 MB/s [... similar for each disk ...] # time parallel -j0 "dd if=/dev/{} skip=15000000 bs=256k count=4000 | cat >/dev/null" ::: sdbd sdbc sdbf sdbm sdbl sdbk sdbe sdbj sdbh sdbg 4000+0 records in 4000+0 records out 1048576000 bytes (1.0 GB) copied, 12.7991 s, 81.9 MB/s [... similar for each disk ...] So we can read sequentially at 140 MB/s in the outer tracks and 82 MB/s in the inner tracks on all the drives simultaneously. Sequential write performance is similar. This would lead me to expect a rebuild speed of 82 MB/s or more. # echo 800000 > /proc/sys/dev/raid/speed_limit_min # echo 800000 > /proc/sys/dev/raid/speed_limit_max # cat /proc/mdstat md2 : active raid6 sdbd[10](S) sdbc[9] sdbf[0] sdbm[8] sdbl[7] sdbk[6] sdbe[11] sdbj[4] sdbi[3](F) sdbh[2] sdbg[1] 27349121408 blocks super 1.2 level 6, 128k chunk, algorithm 2 [9/8] [UUU_UUUUU] [=========>...........] recovery = 47.3% (1849905884/3907017344) finish=855.9min speed=40054K/sec But we only get 40 MB/s. And often this drops to 30 MB/s. # iostat -dkx 1 sdbc 0.00 8023.00 0.00 329.00 0.00 33408.00 203.09 0.70 2.12 1.06 34.80 sdbd 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 sdbe 13.00 0.00 8334.00 0.00 33388.00 0.00 8.01 0.65 0.08 0.06 47.20 sdbf 0.00 0.00 8348.00 0.00 33388.00 0.00 8.00 0.58 0.07 0.06 48.00 sdbg 16.00 0.00 8331.00 0.00 33388.00 0.00 8.02 0.71 0.09 0.06 48.80 sdbh 961.00 0.00 8314.00 0.00 37100.00 0.00 8.92 0.93 0.11 0.07 54.80 sdbj 70.00 0.00 8276.00 0.00 33384.00 0.00 8.07 0.78 0.10 0.06 48.40 sdbk 124.00 0.00 8221.00 0.00 33380.00 0.00 8.12 0.88 0.11 0.06 47.20 sdbl 83.00 0.00 8262.00 0.00 33380.00 0.00 8.08 0.96 0.12 0.06 47.60 sdbm 0.00 0.00 8344.00 0.00 33376.00 0.00 8.00 0.56 0.07 0.06 47.60 iostat says the disks are not 100% busy (but only 40-50%). This fits with the hypothesis that the max is around 80 MB/s. Since this is software raid the limiting factor could be CPU. top says: PID USER PR NI VIRT RES SHR S %CPU %MEM TIME+ COMMAND 38520 root 20 0 0 0 0 R 64 0.0 2947:50 md2_raid6 6117 root 20 0 0 0 0 D 53 0.0 473:25.96 md2_resync So md2_raid6 and md2_resync are clearly busy taking up 64% and 53% of a CPU respectively, but not near 100%. The chunk size (128k) of the RAID was chosen after measuring which chunksize gave the least CPU penalty. If this speed is normal: What is the limiting factor? Can I measure that? If this speed is not normal: How can I find the limiting factor? Can I change that?

    Read the article

  • PowerPoint slide resolution? (Optimizing video playback)

    - by Dan
    In PowerPoint 2007, there seems to be no way of changing the resolution slide (only the aspect ratio and the output resolution can be chnaged?). If this is the case, then how do I optimize an inserted video for playback using an HD projector? Can I simply insert a video at high resolution and scale it down to fit the slide? Will these extra pixels come to use if the output resolution is high? Thanks!

    Read the article

  • Are these acceptable temperatures for my laptop?

    - by WilliamKF
    I just installed SpeedFan 4.0 since my laptop's fan seems to be continually running at a high speed. It reports these numbers: GPU: 74C Temp1 (ACPI): 75C Temp2 (ACPI): 95C Core 0: 89C Core 1: 89C These seem awfully high to me, should I be concerned? This is an HP EliteBook 8730w with Intel(R) Core(TM)2 Extreme CPU X9100 @ 3.06GHz and nVidia Quadro FX 3700M.

    Read the article

  • Are these acceptable temperatures for my laptop?

    - by WilliamKF
    I just installed SpeedFan 4.0 since my laptop's fan seems to be continually running at a high speed. It reports these numbers: GPU: 74C Temp1 (ACPI): 75C Temp2 (ACPI): 95C Core 0: 89C Core 1: 89C These seem awfully high to me, should I be concerned? This is an HP EliteBook 8730w with Intel(R) Core(TM)2 Extreme CPU X9100 @ 3.06GHz and nVidia Quadro FX 3700M.

    Read the article

  • Server Load Check

    - by ntechi
    Is it possible to trace which file or process or database query is effecting the load on a VPS? I am using Centos with 512 MB Guarantee Memory and 1 GB burst Memory, I am running 3 wordpress sites from it, where all are having daily traffic of 30-100 visitors each, After every 2-3 days I need to restart my VPS because the resources are taking high usage of memory, I tried running top command and it shows Apache as high, But is it possible to check which website is taking load? Here is my 'top -c' command output results

    Read the article

  • Determining which database instance makes biggest IO

    - by user2008937
    Assuming that I have a dedicated server on which I am running multiple instances of mysql and postresql servers. How without iotop determine which instance in particular time (proc/pid/io shows data collected in some peroid of time) makes the biggest IO (so it increases IOWAIT)? When lots of ppl do something on DB then I clearly see which instance is making the load because of high cpu usage, but I had a situation when the cpu usage was just normal, but very high iowait made a huge load on server and i had problem finding process that was making some outstanding IO

    Read the article

< Previous Page | 109 110 111 112 113 114 115 116 117 118 119 120  | Next Page >