  • How to sketch out an event-driven system?

    - by Jordan
    I'm trying to design a system in Node.js (an attempt at solving one of my earlier problems, using Node's concurrency) but I'm running into trouble figuring out how to draw a plan of how the thing should operate. I'm getting very tripped up thinking in terms of callbacks instead of returned values. The flow isn't linear, and it's really boggling my ability to draft it. How does one draw out an operational flow for an event-driven system? I need something I can look at and say "Ok, yes, that's how it will work. I'll start it over here, and it will give me back these results over here." Pictures would be very helpful for this one. Thanks. Edit: I'm looking for something more granular than UML, specifically, something that will help me transition from a blocking and object-oriented programming structure, where I'm comfortable, to a non-blocking and event driven structure, where I'm unfamiliar.

    Read the article

  • Active Directory Time Synchronisation - Time-Service Event ID 50

    - by George
    I have an Active Directory domain with two DCs. The first DC in the forest/domain is Server 2012, the second is 2008 R2. The first DC holds the PDC Emulator role. I sporadically receive a warning from the Time-Service source, event ID 50: The time service detected a time difference of greater than %1 milliseconds for %2 seconds. The time difference might be caused by synchronization with low-accuracy time sources or by suboptimal network conditions. The time service is no longer synchronized and cannot provide the time to other clients or update the system clock. When a valid time stamp is received from a time service provider, the time service will correct itself. Time sync in the domain is configured with the second DC to synchronise using the /syncfromflags:DOMHIER flag. The first DC is configured to sync time using a /syncfromflags:MANUAL /reliable:YES, from a peerlist consisting of a number of UK based stratum 2 servers, such as ntp2d.mcc.ac.uk. I'm confused why I receive this event warning. It implies that my PDC emulator cannot synchronise time with a supposedly reliable external time source, and it quotes a time difference of 5 seconds for 900 seconds. It's worth also mentioning that I used to use a UK pool from ntp.org but I would receive the warning much more often. Since updating to a number of UK based academic time servers, it seems to be more reliable. Can someone with more experience shed some light on this - perhaps it is purely transient? Should I disregard the warning? Is my configuration sound? EDIT: I should add that the DCs are virtual, and installed on two separate VMware ESXi/vSphere physical hosts. I can also confirm that as per MDMarra's comment and best practice, VMware timesync is disabled, since: c:\Program Files\VMware\VMware Tools\VMwareToolboxCmd.exe timesync status returns Disabled. EDIT 2 Some strange new issue has cropped up. I've noticed a pattern. Originally, the event ID 50 warnings would occur at about 1230pm each day. This is interesting since our veeam backup happens at 12 midday. Since I made the changes discussed here, I now receive an event ID 51 instead of 50. The new warning says that: The time sample received from peer server.ac.uk differs from the local time by -40 seconds (Or approximately 40 seconds). This has happened two days in a row. Now I'm even more confused. Obviously the time never updates until I manually intervene. The issue seems to be related to virtualisation and veeam. Something may be occuring when veeam is backing up the PDCe. Any suggestions? UPDATE & SUMMARY msemack's excellent list of resources below (the accepted answer) provided enough information to correctly configure the time service in the domain. This should be the first port of call for any future people looking to verify their configuration. The final "40 second jump" issue I have resolved (there are no more warnings) through adjusting the VMware time sync settings as noted in the veeam knowledge base article here: http://www.veeam.com/kb1202 In any case, should any future reader use ESXi, veeam or not, the resources here are an excellent source of information on the time sync topic and msemack's answer is particularly invaluable.

    Read the article

  • PHP AJAX mysql event calendar - UI for events spanning multiple days

    - by play
    I have built a PHP calendar system and have pretty much everything done but not sure how to deal with a UI issue involving how the events that stretched out over a couple of days. I want to be able to stretch an event that stretches over couple of days in a div that spans those days in the calendar. Basically I would like to know how to achieve what these guys have achieved with the event that stretches out from 21st to 22nd with the yellow div background. I have been trying to see how I can do it with PHP but I feel like I might be trying the wrong thing. Perhaps this is done with javascript?

    Read the article

  • Ext RowEditor.js does not fire 'afteredit' event

    - by terrani
    Hi, I have a Ext grid with RowEditor plugin. I have the following code to add 'afteredit' event to the roweditor object. store.on('update',function(){ }); editor.on("afteredit",function(roweditor,changes,record,index){ $.ajax({ url: $("#web").val() + "/registration/client/address-save" ,type: 'post' ,data: record.json ,dataType: 'json' ,success: function(data){ if(data.success == true){ alert("Update Successfully"); } } }); }); when I click a row and edit a value, sometimes the grid fires 'afteredit' event, but sometimes it doesn't. Do I have a problem with my code above?

    Read the article

  • jQyery bind on ajax load() event

    - by Andrei C
    Hi guys. I have a page which display multiple blocks with results details. Inside each block I have some tags with thichbox jQuery plugin attached( class="thichbox"). http://jquery.com/demo/thickbox/ here is an example of one kind of ampersant tag: <a class="thickbox" title="Please Sign In" href="userloginredir.php?height=220&width=350&deal=3"> Problem comes when I added a jQuery pagination to the page because of to many results displaying on the page. The div component with the results inside is updated through ajax load() event. Below is the pagination script. $(document).ready(function(){ //References var pages = $("#menu_deals li"); var loading = $("#loading_deals"); var content = $("#content_deals"); //show loading bar function showLoading(){ loading .css({visibility:"visible"}) .css({opacity:"1"}) .css({display:"block"}) ; } //hide loading bar function hideLoading(){ loading.fadeTo(1000, 0); }; //Manage click events pages.live('click',function(){ //show the loading bar showLoading(); //Highlight current page number pages.css({'background-color' : ''}); $(this).css({'background-color' : 'yellow'}); //Load content var pageNum = this.id; var targetUrl = "ajax_search_results.php?page=" + pageNum + "&" + $("#dealsForm").serialize() + " #content_d"; content.load(targetUrl, hideLoading); }); //default - 1st page $("#1").css({'background-color' : 'yellow'}); var targetUrl = "ajax_search_results.php?page=1&" + $("#dealsForm").serialize() + " #content_d"; showLoading(); content.load(targetUrl, hideLoading); }); When I added pagination(code above), the thickbox events are not recognized anymore and instead of poping out a window with the login form inside it opens the results in new page (is acting like clicking on a normal link) From my jQuery knowledge this means that the components are not defined in the DOM because the content is updated after document ready triggered. I'm trying to bind the load event with something like this: content.bind('load',???); But I don't know how to pass the load params, targetUrl and the callback function hideLoading, when binding the load event. Please help me out in this matter, already took me more time than possible allowed. Thank you!

    Read the article

  • Why does this C# event handler not respond to this event in this Silverlight application?

    - by Edward Tanguay
    Can anyone tell me why the following code successfully executes this event: OnLoadingComplete(this, null); but never executes this event handler? void initialDataLoader_OnLoadingComplete(object obj, DataLoaderArgs args) CODE: using System; using System.Collections.Generic; using System.Linq; using System.Windows.Controls; using System.Diagnostics; namespace TestEvent22928 { public partial class MainPage : UserControl { public MainPage() { InitializeComponent(); DataLoader initialDataLoader = new DataLoader("initial"); initialDataLoader.RegisterText("test1", "http://test:111/testdata/test1.txt"); initialDataLoader.RegisterText("test2", "http://test:111/testdata/test2.txt"); initialDataLoader.BeginLoading(); initialDataLoader.OnLoadingComplete += new DataLoader.LoadingComplete(initialDataLoader_OnLoadingComplete); } void initialDataLoader_OnLoadingComplete(object obj, DataLoaderArgs args) { Debug.WriteLine("loading complete"); //WHY DOES EXECUTION NEVER GET HERE? } } public class DataManager { public DataLoader CreateDataloader(string dataloaderIdCode) { DataLoader dataLoader = new DataLoader(dataloaderIdCode); return dataLoader; } } public class DataLoader { public string IdCode { get; set; } public List<DataItem> DataItems { get; set; } public delegate void LoadingComplete(object obj, DataLoaderArgs args); public event LoadingComplete OnLoadingComplete = delegate { }; private int dataItemCurrentlyLoadingIndex; public DataLoader(string idCode) { IdCode = idCode; DataItems = new List<DataItem>(); dataItemCurrentlyLoadingIndex = -1; } public void RegisterText(string idCode, string absoluteSourceUrl) { DataItem dataItem = new DataItem { IdCode = idCode, AbsoluteSourceUrl = absoluteSourceUrl, Kind = DataItemKind.Text }; DataItems.Add(dataItem); } public void BeginLoading() { LoadNext(); } private void LoadNext() { dataItemCurrentlyLoadingIndex++; if (dataItemCurrentlyLoadingIndex < DataItems.Count()) { DataItem dataItem = DataItems[dataItemCurrentlyLoadingIndex]; Debug.WriteLine("loading " + dataItem.IdCode + "..."); LoadNext(); } else { OnLoadingComplete(this, null); //EXECUTION GETS HERE } } } public class DataItem { public string IdCode { get; set; } public string AbsoluteSourceUrl { get; set; } public DataItemKind Kind { get; set; } public object DataObject { get; set; } } public enum DataItemKind { Text, Image } public class DataLoaderArgs : EventArgs { public string Message { get; set; } public DataItem DataItem { get; set; } public DataLoaderArgs(string message, DataItem dataItem) { Message = message; DataItem = dataItem; } } }

    Read the article

  • Why do System.IO.Log SequenceNumbers have variable length?

    - by Doug McClean
    I'm trying to use the System.IO.Log features to build a recoverable transaction system. I understand it to be implemented on top of the Common Log File System. The usual ARIES approach to write-ahead logging involves persisting log record sequence numbers in places other than the log (for example, in the header of the database page modified by the logged action). Interestingly, the documentation for CLFS says that such sequence numbers are always 64-bit integers. Confusingly, however, the .Net wrapper around those SequenceNumbers can be constructed from a byte[] but not from a UInt64. It's value can also be read as a byte[], but not as a UInt64. Inspecting the implementation of SequenceNumber.GetBytes() reveals that it can in fact return arrays of either 8 or 16 bytes. This raises a few questions: Why do the .Net sequence numbers differ in size from the CLFS sequence numbers? Why are the .Net sequence numbers variable in length? Why would you need 128 bits to represent such a sequence number? It seems like you would truncate the log well before using up a 64-bit address space (16 exbibytes, or around 10^19 bytes, more if you address longer words)? If log sequence numbers are going to be represented as 128 bit integers, why not provide a way to serialize/deserialize them as pairs of UInt64s instead of rather-pointlessly incurring heap allocations for short-lived new byte[]s every time you need to write/read one? Alternatively, why bother making SequenceNumber a value type at all? It seems an odd tradeoff to double the storage overhead of log sequence numbers just so you can have an untruncated log longer than a million terabytes, so I feel like I'm missing something here, or maybe several things. I'd much appreciate it if someone in the know could set me straight.

    Read the article

  • AppDomain.UnhandeledException event not fired

    - by Yaakov Davis
    In a WPF application, the app simply crashes, without the above event being fired. (I'm also registered to DispatcherUnhandeledException, which doesn't fire as well.) I conclude that it doesn't fire since the handler is defined to place a log entry. When looking at the log, there's no corresponding entry. It happens in a production environment; I'm unable to point at a particular scenario. I've read few descriptions on scenarios where this might happen, but I still don't have a clear grasp on this. Can anyone share his experience / knowledge on this? How can I find the root of the crash and solve it? Many thanks.

    Read the article

  • How to use Event notification in Solaris 10 when a directory change

    - by user357594
    I read the following page: Robert Benson's article on ECF developers.sun.com/solaris/articles/event_completion.html I also read the Solaris man pages but they are not very clear of how to use event notifications for directories. For example, If I add a new file into a directory, I would like to get some notification of that event. I found this link: blogs.sun.com/praks/entry/file_events_notification Which has what I need but it is for Solaris 11 ( which is not in the market yet). Based on the link below, I don't want to use poll because I want to get the performance advantage of events. blogs.sun.com/dap/entry/event_ports_and_performance Any suggestion is highly appreciated! -Armando.

    Read the article

  • Visual Studio 2008. MFC event wizard broken

    - by G Forty
    OK, so it's almost a programming question - The VS2008 dialog event wizard has stopped working. Double-clicking on a button in an MFC dialog project does not fire the wizard as usual and a right-click to get to the 'Add Event Handler...' shows a dialog with no message types. Further to this the MFC message mapping and virtual class listing that generally appears in the properties window (Alt + Enter) is now empty. Has anyone elese seen this and if so, how'd they fix it? I have 'repaired' my VS08 installation ... Thx++ Jerry

    Read the article

  • How to get the current eventNumber for creating an event with NSEvent

    - by Chris
    Hello I'm creating an os x application for which I try to add a remote interface. For this I need to be able to send mouse down and mouse up commands to the window of my application. I found code with which I can successfully do this, it looks as follows: int mask = 0x100; NSEvent* eventMouseDown = [NSEvent mouseEventWithType:NSLeftMouseDown location:p modifierFlags:mask timestamp:[NSDate timeIntervalSinceSystemStartup] windowNumber:[w windowNumber] context:[NSGraphicsContext graphicsContextWithWindow:w] eventNumber:++eventCounter +42599 clickCount:1 pressure:0]; NSLog(@"Mouse down event: %@", eventMouseDown); [[NSApplication sharedApplication] sendEvent:eventMouseDown]; I have only one problem with this code thought and this is the eventNumer parameter. As far as I found out it is a number which get increased with each event. But I cannot find a way to find the current number from where on I need to increase. The number I use there currently is just try and error and also does not seam to work always.

    Read the article

  • How to change a field value during the ItemUpdating event

    - by Buzzby
    Hi I am trying to set the value of a field on a ListItem in an event receiver but its not working All i am doing during the event is properties.AfterProperties[<field internal name>] = 1; No errors are thrown but the the field i'm setting does not change. I have also tried properties.ListItem[<field internal name>] = 1; properties.ListItem.Update(); Have also tried SystemUpdate(); I know i am meant to be setting the afterproperties but think i am missing an obvious step. Thanks

    Read the article

  • C# event or delegate or other solution?

    - by user295734
    Looking for some help or programmng ideas or mayeb there is some pattern that would help. Have an application that needs to fire alot of events sequentially, it could up to 100 or more unique events, it will be dynamic depeneding on the situation. Trying to find the best practice for doing this. My main idea right now is to create a list of objects iterate thru them, and fire each event. This seems wrong, or bad practice. Or maybe have one object and pass a list or params into one event? Or am I missing some feature in .NET that i could be using or implementing?

    Read the article

  • how change nginx temp & log folder or disable logging completely

    - by Ehsan Khodarahmi
    I'm running nginx 1.3.5 under windows seven, I need to execute nginx directly from a read-only media (CD or DVD), but when I want to run it, it fails with this error: nginx: [alert] could not open error log file: CreateFile() "logs/error.log" fail ed (5: Access is denied) 2012/08/28 13:52:46 [emerg] 5604#2864: CreateDirectory() "J:\nginx-1.3.5/temp/client_body_temp" failed (5: Access is denied) where J is my CD-ROM drive letter. I've changed nginx.conf to disable logging completely, but seems anyway it still tries to build a file named 'error.log' in '/logs' folder & some extra temporary contents in '/temp' folder at the startup, so I want to change 'logs' & 'temp' directory path to windows temp folder (%temp%), but I dont have any idea that how can I do it. Also I want to know why nginx still creates 'logs/error.log' after disableing error logging ?

    Read the article

  • How to check if windows has automatic updates waiting from the command line?

    - by Lee
    If a Windows server (2k3/2k8) is set to "download but not install" updates, is there a way to check from the command line.. perhaps a log file or something I can check with powershell, to see if there are any updates actually waiting to be installed? I'm trying to prevent having to manually log on to each server to check, even though they want the "trigger" pulled manually. We have an automation system in place I can use (CA Autosys) - just not sure what to have it look for.

    Read the article

  • C# property in a form class only accessable after formload event

    - by Spooky2010
    using vs2008, c# Howdy, Im instantiating and calling Form B from Form A. FormB has some custom properties, to allow me to pass it things like sqlAdaptors and dataset instances. When i instantiate and show Form B from Form A as a dialog form with a Using statement, it all works fine, but i find the properties i pass are not available in Form B until after the form_load event has fired. I was under the impression the properties when passed to a instantiated class should be available from a constructor, but this is not the case. If it try to access the properties before the form load event i get a null reference exception. Is this correct behavior ? It is very annoying. thanks for any help

    Read the article

  • Javascript Prototype Best Practice Event Handlers

    - by nahum
    Hi this question is more a consulting of best practice, Sometimes when I'm building a complete ajax application I usually add elements dynamically for example. When you'r adding a list of items, I do something like: var template = new Template("<li id='list#{id}'>#{value}</li>"); var arrayTemplate = []; arrayOfItem.each(function(item, index){ arrayTemplate.push(template.evaluate( id : index, value : item)) }); after this two options add the list via "update" or "insert" ----- $("elementToUpdate").update("<ul>" + arrayTemplate.join("") + "</ul">); the question is how can I add the event handler without repeat the process of read the array, this is because if you try add a Event before the update or insert you will get an Error because the element isn't still on the DOM. so what I'm doing by now is after insert or update: arrayOfItem.each(function(item, index){ $("list" + index).observe("click", function(){ alert("I see the world"); }) }); so the question is exist a better way to doing this??????

    Read the article

  • Google maps event problem with flex actionscript

    - by DEH
    I am able to render a google map on a flex canvas. I create the map using the code below and then place markers on it in the onMapReady method (not shown) var map:com.google.maps.Map=new com.google.maps.Map(); map.id="map"; map.key="bla bla"; _mapCanvas.addChild(map); map.addEventListener(MapEvent.MAP_READY,onMapReady); It all works fine. However, if I remove the map and then set _mapCanvas to null, then run exactly the same code again, the onMapReady event does not fire. It is weird, but once a map has been created and deleted, the onMapReady event never seems to fire again. Anyone got any ideas? Thanks.

    Read the article

  • Basic QT Event handling / Threading questions ?

    - by umanga
    Greetings , I am new to QT (4.6) and have some basic questions regarding its event mechanism.I come from Swing background so I am trying to compare it with QT. 1) Does Event-processing-loop run in seperate thread? (like EventDispatch thread in Swing) ? 2) If we open several 'QMainWindow' do they run in several threads? 3) Whats the best way to run an intensive process in a seperate thread? (like SwingWorker in Swing ? ) 4) If intesive-process runs in a seperate thread ,is it possible to call UI methods like update(),repaint() from that process? thanks in advance.

    Read the article

  • WPF UserControl event called only once?

    - by 742
    Hi Everyone, I need to bind two-way a property of a user control to a property of a containing user control. I also need to set a default value to the property from code in the child (cannot be done easily from XAML tags). If I call my code from the child constructor, the value is set in the parent but the change callback routine is not triggered (my understanding is that the parent doesn't yet exist at the time the child is created). My current workaround is to catch the Loaded event of the child and to call the code from the handler. Howver as Loaded is called more than once, I need to set a flag to set the property only the first time. I don't like this way, but I don't know if there is a single shot event that could be used, or if this can be done otherwise. Any feedback based on your experience?

    Read the article

  • How to add the UAC shield icon to program that still must target XP?

    - by bsruth
    I have a program that still must target Windows XP (_WIN32_WINNT 0x501), as most of our customers still use XP. However, we have been shipping Vista for a while, and are now pushing Windows 7 upgrades. For the software to work correctly on the newer OSs, there are a couple operations that require UAC elevation. I have the elevation code working, but would like to have the UAC icon present on the buttons that launch the UAC process. Unfortunately, all of the options defined in Microsoft's UAC UI document require _WIN32_WINNT 0x600 or newer. Is there any way to get the appropriate UAC icon (Vista and 7 use different ones) to show on the button while still being able to target XP (where no icon will be shown)? I'm using C++, but may be able to adapt a .NET solution.