Search Results

Search found 3956 results on 159 pages for 'scripting bridge'.

Page 135/159 | < Previous Page | 131 132 133 134 135 136 137 138 139 140 141 142  | Next Page >

  • How do I stop linux from trying to mount android phone as usb storage?

    - by user1160711
    When I plug in my Motorola Triumph to my fedora 17 linux box USB port, I get an endless series of errors on the linux box as it desperately attempts to mount the phone as a USB drive. Stuff like this: Jun 23 10:26:00 zooty kernel: [528926.714884] end_request: critical target error, dev sdg, sector 4 Jun 23 10:26:00 zooty kernel: [528926.715865] sd 16:0:0:1: [sdg] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE Jun 23 10:26:00 zooty kernel: [528926.715869] sd 16:0:0:1: [sdg] Sense Key : Illegal Request [current] Jun 23 10:26:00 zooty kernel: [528926.715872] sd 16:0:0:1: [sdg] Add. Sense: Invalid field in cdb Jun 23 10:26:00 zooty kernel: [528926.715876] sd 16:0:0:1: [sdg] CDB: Read(10): 28 20 00 00 00 00 00 00 04 00 If I go ahead and tell the phone to allow linux to mount the USB storage, the messages stop, and I get a mounted drive, but if all I want to do is use the debug bridge, my log on linux will continue to fill with this junk. Is there some udev magic I can do to make the system ignore this particular device as far as usb storage goes? I just noticed that if I tell the phone to enable USB storage, let linux recognize the new disk, then tell the phone to disable USB storage again, I get one additional log message about capacity changing to zero, but the endless spew of messages stops, so I guess one work around is to enable and disable USB right away.

    Read the article

  • tc u32 --- how to match L2 protocols in recent kernels?

    - by brownian
    I have a nice shaper, with hashed filtering, built at a linux bridge. In short, br0 connects external and internal physical interfaces, VLAN tagged packets are bridged "transparently" (I mean, no VLAN interfaces are there). Now, different kernels do it differently. I can be wrong with exact kernel verions ranges, please forgive me. Thanks. 2.6.26 So, in debian, 2.6.26 and up (up to 2.6.32, I believe) --- this works: tc filter add dev internal protocol 802.1q parent 1:0 prio 100 \ u32 ht 1:64 match ip dst 192.168.1.100 flowid 1:200 Here, "kernel" matches two bytes in "protocol" field with 0x8100, but counts the beginning of ip packet as a "zero position" (sorry for my English, if I'm a bit unclear). 2.6.32 Again, in debian (I've not built vanilla kernel), 2.6.32-5 --- this works: tc filter add dev internal protocol 802.1q parent 1:0 prio 100 \ u32 ht 1:64 match ip dst 192.168.1.100 at 20 flowid 1:200 Here, "kernel" matches the same for protocol, but counts offset from the beginning of this protocol's header --- I have to add 4 bytes to offset (20, not 16 for dst address). It's ok, seems more logical, as for me. 3.2.11, the latest stable now This works --- as if there is no 802.1q tag at all: tc filter add dev internal protocol ip parent 1:0 prio 100 \ u32 ht 1:64 match ip dst 192.168.1.100 flowid 1:200 The problem is that I couldn't find a way to match 802.1q tag so far. Matching 802.1q tag at past I could do this before as follows: tc filter add dev internal protocol 802.1q parent 1:0 prio 100 \ u32 match u16 0x0ed8 0x0fff at -4 flowid 1:300 Now I'm unable to match 802.1q tag with at 0, at -2, at -4, at -6 or like that. The main issue that I have zero hits count --- this filter is not being checked at all, "wrong protocol", in other words. Please, anyone, help me :-) Thanks!

    Read the article

  • KVM Hosting: How to efficiently replicate guests

    - by javano
    I have three KVM servers each with 1 guest VM, running directly on it's local storage, (so they are essentially getting a dedicated box worth of computing power each). In the event of a host failure I would like the guests replicated to at least one of the other hosts so I can spin it up there, until the failing host is fixed. I am curious about KVM cloning. I can clone a VM live or when it's suspended/shutdown. Obivously suspended VMs will naturally be quicker to clone but these three VMs comprise three parts of a single solution, so I don't want to ever have any one of them shutdown. How can I efficiently clone these VMs between servers? I have had a couple of ideas, but are these insane or, is there a better method I have missed for my scenario? Set up a DRDB partition between box 1 and 2 where VM 1 runs from, and so is replicated between box1 and box 2, repeat between box 2 & 3, and box 3 & 1 (This could be insane, I have never used DRDB only read about it) Just use standard KVM CLI clone options to perform live clones (I'm dubious about this because I don't know how long it will take and what the performance impact will be during) Run a copy of each VM on at least one other host, and have the guest on one host export it's data to the matching guest on another host where it can import that data, scripting this on the guest) Some of other way? Ideas welcome! Side Note These servers have 4x15k SAS drives in a RAID 10 so they aren't rocketing fast, and as I mentioned, each VM runs from the host's local storage, no NAS or SAN etc. So that is why I am asking this question about guest replication. Also, this isn't about disaster recovery. Guests will be exporting their data to a NAS over a VPN, so I am looking at how I can have them quickly spun up in a host failure situation.

    Read the article

  • Cisco Catalyst 3550 + Alteon 184 Load-Balancing Issues

    - by upkels
    I have just deployed a couple Cisco Catalyst 3550 switches, and a couple Alteon 184 Web Switches for load-balancing. I can ping all RIPs and VIPs to/from the Alteon. Topology Before: (server) <- (Alteon) <- (Internet) Topology Now: (server) <- (3550) <- Alteon <- (Internet) Cisco Port Configuration (Alteon Uplink Port): description LB_1_PORT_9_PRIMARY switchport access vlan 10 switchport mode access switchport nonegotiate speed 100 duplex full Alteon Port 9 Configuration (VLAN 10 WAN): >> Main# /c/port 9/cur Current Port 9 configuration: enabled pref fast, backup gig, PVID 10, BW Contract 1024 name UPLINK >> Main# /c/port 9/fast/cur Current Port 9 Fast link configuration: speed 100, mode full duplex, fctl none, auto off Cisco Configuration (Load-Balanced Servers Port): description LB_1_PORT_1_PRIMARY switchport access vlan 30 switchport mode access switchport nonegotiate speed 100 duplex full Alteon Port 1 Configuration (VLAN 30 LOAD-BALANCED LAN): >> Main# /c/port 1/cur Current Port 1 configuration: enabled pref fast, backup gig, PVID 30, BW Contract 1024 name LB_PORT_1 >> Main# /c/port 1/fast/cur Current Port 1 Fast link configuration: speed 100, mode full duplex, fctl both, auto on Each of my servers are on vlan 10 and 30, properly communicating. I have tried to turn on VLAN tagging on the Alteon, however it seems to cause all communications to stop working. When I tcpdump -i vlan30 on any of the webservers, I see normal ARP communications, and some STP communications, which may or may not be part of the problem: ... 15:00:51.035882 STP 802.1d, Config, Flags [none], bridge-id 801e.00:11:5c:62:fe:80.8041, length 42 15:00:51.493154 IP 10.1.1.254.33923 > 10.1.1.1.http: Flags [S], seq 707324510, win 8760, options [mss 1460], length 0 15:00:51.493336 IP 10.1.1.1.http > 10.1.1.254.33923: Flags [S.], seq 3981707623, ack 707324511, win 65535, options [mss 1460], len gth 0 15:00:51.493778 ARP, Request who-has 10.1.3.1 tell 10.1.3.254, length 46 etc... I'm not sure if I've provided enough information, so please let me know if any more is necessary. Thank you!

    Read the article

  • How to configure network on Windows Server 2008

    - by Gokhan Ozturk
    I have a IBM x3400 Server Machine with Windows Server 2008 R2 installed on it. But, since I am not expert on networking I have some problems. These roles installed on my server: Active Directory DNS File Sharing Hyper-V ISS VPN There is two network card on them. I configured them like this: Local Connection 1: 192.168.30.3 255.255.255.0 192.168.30.2 127.0.0.1 Local Connection 2: 192.168.30.101 255.255.255.0 192.168.30.6 127.0.0.1 My problem is, when I use this Ip gateways, It is sharing internet to all computers. This is not I want. I want to use Local Connection 1 for internal network. I am giving all computers gateway and DNS IP as 192.168.30.3 The Local Connection 2 is for Hyper-V and VPN connections. 192.168.30.2 and 192.168.30.6 are my modem's gateways. I am using 192.168.30.6 external IP for VPN connections. There is two 24 port switches. There is a connection between them and this two ethernet card connected directly to them. And modems are connected to switches as well (Morems are not near the server. They are somewhere in the building). I disabled network Bridge and removed all ethernet cards from it. With this configuration, all computers can ping my server's IP (192.168.30.3) but on server I cannot ping any clients (Request timeout). What is the best way to configure my network? Thank you. Redgards

    Read the article

  • Connect two networks

    - by Meek Barrios
    Connecting two different offices with a wireless link and linux boxes. Hardware: 2 CISCO RV42, 2 Dual Homed Linux Boxes running debian, 2 2Wire and 2 AirMax 5 Configuration is: Office A LAN A (10.1.1.0/24) -> RV42 A (WAN1 - 10.1.1.254) -> 2Wire A (Internet) LINUX A ( ETH0 (LAN) 10.1.1.253, ETH1 (LINK) (10.1.3.3) Wireless Link --- AirMax A <-> AirMax B connected as Wireless Bridge Office B LAN B (10.1.2.0/24) -> RV42 B (WAN1 - 10.1.2.254) -> 2Wire B (Internet) LINUX B ( ETH0 (LAN) 10.1.2.253 -> ETH1 (LINK) (10.1.3.4) Network configuration is: LAN A - Default Gateway 10.1.1.254 RV42 A - Static Route 10.1.3.0/24 on 10.1.1.253 Static Route 10.1.2.0/24 on 10.1.1.253 Default on 192.168.1.1 (WAN1 Internet Access) Linux A - ETH0 10.1.1.253 netmask 255.255.255.0 gw 10.1.1.254 ETH1 10.1.3.3 netmask 255.255.255.0 gw 10.1.3.1 AIRMAX A - 10.1.3.1 netmask 255.255.255.0 gw 10.1.3.1 LAN B - Default Gateway 10.1.2.254 RV42 B - Static Route 10.1.3.0/24 on 10.1.2.253 Static Route 10.1.1.0/24 on 10.1.2.253 Default on 192.168.1.1 (WAN1 Internet Access) Linux B - ETH0 10.1.2.253 netmask 255.255.255.0 gw 10.1.2.254 ETH1 10.1.3.4 netmask 255.255.255.0 gw 10.1.3.2 AIRMAX B - 10.1.3.2 netmask 255.255.255.0 gw 10.1.3.2 Both linux have ip_forward set to 1 and the following on the iptables: iptables -F iptables -X iptables -P FORWARD ACCEPT iptables -P INPUT ACCEPT iptables -P OUTPUT ACCEPT I can ping from Linux B any ip on 10.1.1.0/24 segment and on linux A any ip on 10.1.2.0/24 segment however I cannot connect to HTTP or FTP on those machines. From LAN A I cannot see any other network. I'm looking for some advice for this configuration or a better solution. Regards

    Read the article

  • Linux boot - stop the kernel switching to a new framebuffer mode clearing output

    - by Avio
    I'm working on an embedded system (based onUbuntu 12.04 LTS) and I'm customizing its kernel. I'm having some problem with upstart, mountall and plymouth. Nothing unsolvable I suppose, but the real problem is that I can't diagnose properly what's going on because the kernel (or maybe plymouth) changes the video mode in the middle of the boot process. This completely wipes entire lines of log and prevents any debugging of kernel misconfigurations. My Grub2 config seems to be ok with: GRUB_CMDLINE_LINUX="" GRUB_CMDLINE_LINUX_DEFAULT="acpi=force noplymouth" GRUB_GFXMODE=1024x768x32 GRUB_GFXPAYLOAD_LINUX=keep Here is some relevant output of lspci: 00:00.0 Host bridge: Intel Corporation Mobile 945GSE Express Memory Controller Hub (rev 03) 00:02.0 VGA compatible controller: Intel Corporation Mobile 945GSE Express Integrated Graphics Controller (rev 03) 00:02.1 Display controller: Intel Corporation Mobile 945GM/GMS/GME, 943/940GML Express Integrated Graphics Controller (rev 03) And here is the relevant portion of my kernel configuration: CONFIG_AGP=y CONFIG_AGP_INTEL=y CONFIG_VGA_ARB=y CONFIG_VGA_ARB_MAX_GPUS=16 CONFIG_DRM=y CONFIG_DRM_KMS_HELPER=y CONFIG_DRM_I915=y CONFIG_DRM_I915_KMS=y CONFIG_VIDEO_OUTPUT_CONTROL=y CONFIG_FB=y CONFIG_FB_BOOT_VESA_SUPPORT=y CONFIG_FB_CFB_FILLRECT=y CONFIG_FB_CFB_COPYAREA=y CONFIG_FB_CFB_IMAGEBLIT=y CONFIG_FB_MODE_HELPERS=y CONFIG_FB_VESA=y CONFIG_BACKLIGHT_LCD_SUPPORT=y CONFIG_BACKLIGHT_CLASS_DEVICE=y CONFIG_VGA_CONSOLE=y CONFIG_VGACON_SOFT_SCROLLBACK=y CONFIG_VGACON_SOFT_SCROLLBACK_SIZE=640 CONFIG_DUMMY_CONSOLE=y CONFIG_FRAMEBUFFER_CONSOLE=y CONFIG_FRAMEBUFFER_CONSOLE_DETECT_PRIMARY=y CONFIG_FONT_8x8=y CONFIG_FONT_8x16=y CONFIG_LOGO=y CONFIG_LOGO_LINUX_MONO=y CONFIG_LOGO_LINUX_VGA16=y CONFIG_LOGO_LINUX_CLUT224=y Every other custom/stock kernel boot fine with that Grub2 config. What I would like to have is a single flow of messages on a single console (retaining one screen resolution) from the bootup logo till the login prompt. Does anybody know what I have to tweak to achieve this?

    Read the article

  • what is the reason behind window service stopped ,whether its due to LAN problems or any other issues

    - by Steve
    I have a windowservice which named Trunk which stopped one day i just want to know the reason behind it? this is an entry in the logs, Nov 15 17:54:04.318 :Trunk-1516:Trunk:handle_control_event:Received CTRL_LOGOFF_EVENT, ignore it Nov 25 15:54:52.157 :Trunk-1516:Trunk:ERROR - Process Restart Count (5) Exceeded for:C:\Program Files\secon\11.1.4\bin\vmd Nov 25 15:54:52.157 :Trunk-1516:Trunk:Stopping Trunk ... Nov 25 15:54:52.314 :Trunk-1516:Trunk:Shutting down, signaled C:\Program F Nov 20 15:54:20.345 :SCBridge.RegisterBridge:Exception in method: ScUtility.ScCommandException (0xa08990002): Exception from HRESULT: 0xa08990002 Supplemental Information: None available. at ScServer.ScServiceProcessorRegistryManager.Attach(String serviceProcessor, ScClientInformation clientInfo, FORCE_ATTACH_SPEC forceAttachToMaster) at ScServer.ScServiceProcessorRegistry.Attach(String serviceProcessor, Object clientInfo) at ScServer.ScServiceProcessorRegistry.Attach(String serviceProcessor) at ServerControlInterface.SCBridge.RegisterBridge(String SPName) for system APOLLOSP0 attempting to attach and register with the Bridge i had seen service is registered with specific account, so i thought that user logged off from the machine that may be the reason behind it or any LAN disconnection problem . But Having taken another look at the above entry we seem to have a constant failure being generated in vmd which causes Trunk to detect vmd requires a restart. Most of the time it works OK and the restart count is anything up to 4. In this case the Trunk log confirms that the Restart Count is 5 and so is considered to be exceeded. Presumably, this triggers the termination of the other services and Trunk is actually doing its job.So, coould this just be a timing issue and we need to increase the tolerance level (i.e restart count) or do we need to address the 0xa08990002 error in vmd?

    Read the article

  • GPO startup script not copying files

    - by marcwenger
    I created a GPO startup script to execute for computers in a specific AD container. The script takes a file from the AD netlogon share and places it on a directory on the computer. Given the right permissions (ie: myself) can execute the script just fine and the file copies. But it doesn't work on startup - the file does not copy over from the AD server. The startup script should run as localsystem (am I right?). So the question is why do the files not copy on startup? Could it be because of: Is it permissions of the local system user? Reading the registry is problematic on startup? Obtaining files from the AD netlogon folder is problematic on startup? Am I missing it completely? My test machine does have the registry key and local directories as described in the script. I myself have standard user permissions on the test machine. AD server is Windows 2008, test client is Windows XP SP3 (and soon to be Windows 7, which I assume permissions issues will be inevitable) Dim wShell, fso, oraHome, tnsHome, key, srcDir Set wShell = WScript.CreateObject("WScript.Shell") Set fso = CreateObject("Scripting.FileSystemObject") key = "HKLM\Software\Oracle\Oracle_Home" On Error Resume Next orahome = wShell.RegRead(key) If err.Number = 0 Then tnsHome = oraHome + "\" + "network\admin\" srcDir = wShell.ExpandEnvironmentStrings("%logonserver%") + "\netlogon\UpdatedFiles\" fso.CopyFile srcDir + "file1.ext", tnsHome, true End If Side note: To ensure that the script is properly deployed, I purposely put some errors in the script, and on the next startup the error message appeared. So I know the GPO is deployed properly.

    Read the article

  • PC -> TV HDMI suddenly doesn't work, any other option does

    - by XSlicer
    So my parents wanted to connect their PC to their TV, so they bought a 10m (35 ft) cable. It all worked perfectly. Then my mom tripped over the cable, breaking it. She somehow got a free replacement, but at the same time some more expensive one from an uncle. Now the problem is that this suddenly doesn't work anymore (TV saying "Format not supported"). I've tried several other things to pinpoint the actual problem, but none brought me something conslusive: PC (hdmi) to TV doesn't work (both cables) PC (hdmi) to TV doesn't work (short cable) Laptop (hdmi) to TV work (same cables) BluRay (hdmi) to TV works (same cables) PC (hdmi) to monitor works (same cables) PC (DVI w/ adapter HDMI) to TV works (same cables) I've tried different ports, tried Linux, reinstalling drivers (the graphics card is internal using an i5 sandy bridge. Normally it's running Windows 7 Home Prem, the TV being a Philips 37PFL7605H). So basically, everything works, except that thing what we want. The only things I am thinking of is that the sound is interfering or that the HDMI-output is somehow broken. Or is it anything else? I'm kind of lost.

    Read the article

  • Why does HP Update at remote system trigger RDP printing at local system?

    - by lcbrevard
    This is obscure. When connected with RDP to another system that has HP Update installed on it, either directly running the HP Update or having the notification pop up to ask if you want to run HP Update causes the local system to try to print something to peculiarly-chosen-local-printer. Case 1: Desktop Win 7 Ult system RDP connected to HP Laptop Win 7 Ult system. When HP Update runs on the laptop a dialog for XPS Writer Save As... appears on Desktop system. Even if you put in a name, nothing gets generated and the dialog repeats. And repeats. Until you (a) close the RDP connection and (b) clean out the queued entries. If the HP Update pops up the request to run the update and you are not at the desk when this happens, there can be dozens of queued requests for this bogus printing. NOTE: the XPS Writer is not selected as a default printer on either system. Case 2: (Different) HP Laptop Win 7 Ult system RDP connected to XP Pro "brand X" desktop system but with HP printer drivers installed. If the request to run HP Update notification pops on the XP system, dozens of attempts to print, in this case to a Versa Check Printer driver, are queued. Dismissing the HP request, closing RDP, and cleaning out the queue are required to stop this. NOTE: the Versa Check Writer is not selected as a default printer on either system. THE QUESTION: What the heck is going on here? Some kind of scripting or COM activity that is misdirected?

    Read the article

  • Integrating PayMill: The token filled input field is not created, error "field_invalid_amount"

    - by automatix
    I'm implementing the Credit Card Payment form of PayMill according to the Payment Form docu. So I copied the JS from the Bridge docu page and the form from the Payment Form docu page. But no token is created. When I try to debug the JS and add console.info(error.apierror); into the paymillResponseHandler(...) function, I get the error code: field_invalid_amount. According to the support page There are three possible reasons for this error message: no amount value was provided numbers were rounded wrong delimiter symbol But the amuont is provided and I've already tried different delimiter symbols. What "numbers were rounded" means, is not clear. What can be the problem and how to fix this issue? Code: <!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.01 Transitional//EN"> <html> <head> <meta name="generator" content="PSPad editor, www.pspad.com"> <script src="https://ajax.googleapis.com/ajax/libs/jquery/1.7.2/jquery.min.js"></script> <title> </title> </head> <body> <!-- PayMill HEAD start --> <link rel="stylesheet" href="https://netdna.bootstrapcdn.com/twitter-bootstrap/2.2.1/css/bootstrap.no-responsive.no-icons.min.css" /> <script type="text/javascript"> var PAYMILL_PUBLIC_KEY = '51668632777bf03b57f861c5a7278a38'; </script> <script type="text/javascript" src="https://bridge.paymill.com/"></script> <!-- PayMill HEAD stop --> <!-- PayMill FORM start --> <form id="payment-form" class="span4" action="payment.php" method="POST"> <p class="payment-errors alert-error span3" style="display:none;"> </p> <div id="payment-form-cc"> <div class="controls controls-row"> <div class="span2"> <label class="card-number-label">Kreditkarte </label> <input class="card-number span2" type="text" size="20" value="4111111111111111"/> </div> <div class="span1"> <label class="card-cvc-label">CVC </label> <input class="card-cvc span1" type="text" size="4" value="111"/> </div> </div> <div class="controls controls-row"> <div class="span3 card-icon"> </div> </div> <div class="controls controls-row"> <div class="span3"> <label class="card-holdername-label">Karteninhaber </label> <input class="card-holdername span3" type="text" size="20" value="lala"/> </div> </div> <div class="controls controls-row"> <div class="span3"> <label class="card-expiry-label">Gültigkeitsdatum (MM/YYYY) </label> <input class="card-expiry-month span1" type="text" size="2" value="12"/> <span style="float:left;"> / </span> <input class="card-expiry-year span1" type="text" size="4" value="2015"/> </div> </div> </div> <div class="controls controls-row"> <div class="span2"> <label class="amount-label">Betrag </label> <input class="amount span2" type="text" size="5" value="9,99" name="amount"/> </div> <div class="span1"> <label class="currency-label">Währung </label> <input class="currency span1" type="text" size="3" value="EUR" name="currency"/> </div> </div> <div class="controls controls-row"> <div class="span4"> <button class="submit-button btn btn-primary" type="submit" >Pay!</button> </div> </div> </form> <!-- PayMill FORM stop --> <!-- PayMill FOOT start --> <script type="text/javascript"> function paymillResponseHandler(error, result) { if (error) { console.info(error.apierror); // Displays the error above the form $(".payment-errors").text(error.apierror); } else { console.info('OK'); var form = $("#payment-form"); // Output token var token = result.token; // Insert token into form in order to submit to server form.append( "<input type='hidden' name='paymillToken' value='"+token+"'/>" ); // Submit form form.get(0).submit(); } } </script> <script type="text/javascript"> paymill.createToken({ number: $('.card-number').val(), // required exp_month: $('.card-expiry-month').val(), // required exp_year: $('.card-expiry-year').val(), // required cvc: $('.card-cvc').val(), // required amount_int: $('.card-amount-int').val(), // required, e.g. "4900" for 49.00 EUR currency: $('.currency').val(), // required cardholder: $('.card-holdername').val() // optional }, paymillResponseHandler); </script> <!-- PayMill FOOT stop --> </body> </html>

    Read the article

  • xen + debian network after upgrade squeeze to wheeze

    - by rush
    I've got a Debian + Xen server. After a system upgrade to the stable version the network doesn't come up after boot. Every time after reboot I need to bring it up manually. The network configuration was not changed during upgrade. Here is /etc/network/interfaces: auto lo iface lo inet loopback auto eth0 iface eth0 inet static address 11.22.33.44 netmask 255.255.255.0 gateway 11.22.33.1 nameserver 8.8.8.8 After boot ip r shows no route and eth0 has no ip address. Manually ip and route setup goes fine and network starts working. Messages from dmesg about network I've found (looks like nothing interesting) [ 3.894401] ACPI: Fan [FAN3] (off) [ 3.894444] ACPI: Fan [FAN4] (off) [ 4.178348] e1000e 0000:00:19.0: eth0: (PCI Express:2.5GT/s:Width x1) 00:1e:67:14:66:c9 [ 4.178351] e1000e 0000:00:19.0: eth0: Intel(R) PRO/1000 Network Connection [ 4.178392] e1000e 0000:00:19.0: eth0: MAC: 10, PHY: 11, PBA No: 0100FF-0FF [ 4.178413] e1000e 0000:02:00.0: Disabling ASPM L0s L1 [ 4.178432] xen: registering gsi 16 triggering 0 polarity 1 -- [ 4.223667] ata5: DUMMY [ 4.223668] ata6: DUMMY [ 4.289153] e1000e 0000:02:00.0: eth1: (PCI Express:2.5GT/s:Width x1) 00:1e:67:14:66:c8 [ 4.289155] e1000e 0000:02:00.0: eth1: Intel(R) PRO/1000 Network Connection [ 4.289245] e1000e 0000:02:00.0: eth1: MAC: 3, PHY: 8, PBA No: 1000FF-0FF [ 4.506908] usb 1-1: new high-speed USB device number 2 using ehci_hcd [ 4.542920] ata2: SATA link up 3.0 Gbps (SStatus 123 SControl 300) -- [ 10.362999] EXT4-fs (dm-23): mounted filesystem with ordered data mode. Opts: (null) [ 10.419103] EXT4-fs (dm-3): mounted filesystem with ordered data mode. Opts: (null) [ 10.988255] ADDRCONF(NETDEV_UP): eth1: link is not ready [ 13.175533] Event-channel device installed. [ 13.287555] XENBUS: Unable to read cpu state -- [ 13.288670] XENBUS: Unable to read cpu state [ 13.965939] Bridge firewalling registered [ 14.134048] e1000e: eth1 NIC Link is Up 1000 Mbps Full Duplex, Flow Control: Rx/Tx [ 14.283862] ADDRCONF(NETDEV_UP): peth0: link is not ready [ 14.284543] ADDRCONF(NETDEV_CHANGE): eth1: link becomes ready [ 17.800627] e1000e: peth0 NIC Link is Up 1000 Mbps Full Duplex, Flow Control: Rx/Tx [ 17.801377] ADDRCONF(NETDEV_CHANGE): peth0: link becomes ready [ 18.307278] device peth0 entered promiscuous mode [ 24.538899] eth1: no IPv6 routers present [ 28.570902] peth0: no IPv6 routers present I've upgraded two servers and I've such behaviour on two of them. How to fix this and get network starts automatically on boot?

    Read the article

  • Trying to communicate between virtual servers on the same host through ipv6

    - by Daniele Testa
    I am running KVM on a host with 2 virtual servers. Each virtual server has a own bridge interface on the host VPS1 has br1 VPS2 has br2 Each virtual server has a own ipv4 and a ipv6. The virtual servers has no problem communicating with internet or with eachother through ipv4. However, with ipv6, they can only communicate with internet and NOT with eachother. The host can ping the 2 virtual servers without any problems, but they cannot ping eachother. iptables has been set to ACCEPT on all chains, so it is not the problem. VPS1 has ipv6 = 2a01:4f8:xxx:xxx::10 VPS2 has ipv6 = 2a01:4f8:xxx:xxx::5 the host has the following routes set: ip route add 2a01:4f8:xxx:xxx::10 dev br1 ip route add 2a01:4f8:xxx:xxx::5 dev br2 When I do a ping from VPS2 to VPS1, I see the following on the host: tcpdump -i br1 15:32:27.704404 IP6 2a01:4f8:xxx:xxx::10 > ff02::1:ff00:5: ICMP6, neighbor solicitation, who has 2a01:4f8:xxx:xxx::5, length 32 So it seems like the host is seeing the request coming from VPS1 on br1. But for some reason, it does not forward it to br2. Instead it is asking where the destination IP is through ipv6 multicast. Anyone has a clue what is going on? I find this very strange, as it is working fine with ipv4 with the exact same settings and routes.

    Read the article

  • Is there a standard method for assigning nameservers to servers in a Windows domain?

    - by HopelessN00b
    As the title asks, I'm wondering if there's any standard or "best practice" for how to actually assign nameservers (DNS) and manage the nameserver configuration for client servers on a Windows domain. I'm talking about the setting circled in the below image, in case the language of the question is not clear enough: This is for a large, multi-site environment, where ideally/hopefully all servers point at their site's Domain Controller as the primary DNS server, and a DNS server at a different site as the secondary DNS server. For simplicity's sake, we can say that the secondary server would be the Domain Controller at the home site for everyone, and there are no tertiary DNS servers (even though that's not actually the case). Try as I might, I can't seem to find a GPO setting for this (at least on FL 2003 R2, the Computer Configuration - Administrative Templates - Network - DNS Client - DNS Servers GPO is Supported on: Windows XP Professional only), and I find it rather hard to believe that the "best"/"standard" solution would therefore be either scripting up something to apply the DNS settings per site, or using a DHCP server to push those configurations out to the other servers via the DHCP Scope Options. So, is there a standard way of managing this configuration? (That's hopefully not "a script" or "DHCP Scope Option.)

    Read the article

  • A web app provider has asked for specific browser config

    - by Matthew
    They have asks to turn off caching on our browsers. I was aghast that they would ask such a thing. I said to them; To avoid caching it is best practice to use; <meta http-equiv="pragma" content="no-cache" /> <meta http-equiv="cache-control" content="no-cache" /> This should work across all browsers. Their reply was; We need to refresh javascript at runtime, this will not help us – any more ideas? I replied; Unsure what you mean by “refresh javascript at runtime”. If you are using ajax, browser caching can effect the XMLHttpRequest open method. Adding these meta tags to the source has fixed this for me in the past. Browser caching only caches resources, it should have no effect on site scripting. These meta tags will bypass browser caching. This is a reasonable request, isn't it?

    Read the article

  • Windows 8 Install Hanging at first white-font boot splash

    - by Omega
    I'm trying to install the Windows 8 preview on my Samsung Series 9 (2012, Ivy Bridge). I've done a bit of a custom scheme with this one: I'm using EFI/UEFI on this system. I've seen no indication that this system supports secure boot (yay!) My SSD is set up with GPT Ubuntu is already installed and working great via UEFI. I'm trying to boot the Windows 8 install from a USB stick via UEFI I don't have access to a CD drive. The problem is that the boot seems to hang at the very first splash screen that looks like this. White windows font, the little beads don't show up. My USB stick has an activity light and it does blink for the first few seconds, but then goes back to it's "nobody is talking to me" idle pulse. What I know: UEFI booting is definitely working. Windows 8 for those few seconds seems to have some kind of access to the USB drive. My Series 9 is running the latest BIOS/firmware. Any idea what I might be able to do to get Windows 8 installed??

    Read the article

  • What is a suitable simple, open web server for Windows?

    - by alficles
    I'm looking for a dead simple web server for Windows. Load will not be high as it will be primarily serving binaries for a WPKG update service. It needs to serve the entire contents of a single folder over HTTP on a configurable (high) port. No CGI or other scripting is required, but it might be nice for future features. I started with Mongoose, since it doesn't even have an installation requirement (a very nice perk), but it fails to start when run as a service. (Technically, it acts as it's own installer.) I've investigated LighTPD as well, but it appears to be minimally (at best) tested on Windows. And naturally, I'm looking for something free. As in beer is good, but speech is better, as always. Edit: I didn't mention this initially, but non-tech people will be doing the install. They'll have whatever script I write for the install, but the goal is a simple system that is easy to troubleshoot. (I almost worded this question "What is the best...", but Serverfault rightly observed that that is a subjective question. And it's really not an optimization problem, any suitable solution will work. I just can't seem to find one for Windows.)

    Read the article

  • Cisco IOS ACL: Don't permit incoming connections just because they are from port 80

    - by cjavapro
    I am going much based on my memory and I may not be correct on all of this. On a Cisco 851 (IOS) that uses a BVI or a bridge-route (the servers on the inside are configured with static and public IP addresses). I would apply two access lists (both end with deny ip any any log) on FastEthernet4 (the WAN port). There would be one for FA4 in and another for FA4 out. FA4 out would have a line like access-list 110 permit 98.76.54.0 0.0.0.255 gt 1023 any eq http I think this means from 98.76.54.* with a from port of at least 1024 can connect to any other machine with a destination port 80. So, then I have to allow the response to the HTTP connection. FA4 in would have a line like access-list 120 permit any eq http 98.76.54.0 0.0.0.255 gt 1023 Now the problem with that is that anybody on the outside can set their from port to port 80 and then connect to any inside port that is at least 1024. How do we prevent this and require the incoming data to be a response to the outgoing data.

    Read the article

  • xrandr fails when 3rd monitor has higher resolution

    - by Pi3cH
    I tried many combinations with xrandr command under lubuntu 12.04 to setup my three monitors DVI (DELL 1) left detected as HDMI1 HDMI (LG E2290) middle detected as HDMI2 VGA (DELL 2) right detected as VGA1 I can get the display with fix 1280x1024 on all the monitors. But once I setup 1280x1024 + 1920x1080 + 1280x1024, I get blank screen on all the monitors. Sometimes it throws crts fail error instead of blanking out. Anyone have similar issues? any solutions/workarounds? P.S. I can setup two monitors using 1280x1280 and 1920x1080 P.S.S. HDMI2 required at least 1920x1080 to display sharp picture. Outputs (it seems graphic card supports up to 8192x8192): xrandr Screen 0: minimum 320 x 200, current 3840 x 1024, maximum 8192 x 8192 VGA1 connected 1280x1024+2560+0 (normal left inverted right x axis y axis) 338mm x 270mm 1280x1024 60.0*+ 75.0 1152x864 75.0 1024x768 75.1 60.0 800x600 75.0 60.3 640x480 75.0 60.0 720x400 70.1 HDMI1 connected 1280x1024+0+0 (normal left inverted right x axis y axis) 376mm x 301mm 1280x1024 60.0*+ 75.0 1152x864 75.0 1024x768 75.1 60.0 800x600 75.0 60.3 640x480 75.0 60.0 720x400 70.1 HDMI2 connected 1280x1024+1280+0 (normal left inverted right x axis y axis) 477mm x 268mm 1920x1080 60.0 + 1680x1050 60.0 1280x1024 75.0 60.0* 1152x864 75.0 1024x768 75.1 60.0 800x600 75.0 60.3 640x480 75.0 60.0 720x400 70.1 DP1 disconnected (normal left inverted right x axis y axis) DP2 disconnected (normal left inverted right x axis y axis) 3 CRTs (0,1 VGA, 0,1,2 for other HDMI) xrandr --verbose VGA1 connected 1280x1024+2560+0 (0x47) normal (normal left inverted right x axis y axis) 338mm x 270mm Identifier: 0x42 Timestamp: 51324 Subpixel: unknown Gamma: 1.0:1.0:1.0 Brightness: 1.0 Clones: CRTC: 0 CRTCs: 0 1 ... HDMI1 connected 1280x1024+0+0 (0x47) normal (normal left inverted right x axis y axis) 376mm x 301mm Identifier: 0x43 Timestamp: 51324 Subpixel: unknown Gamma: 1.0:1.0:1.0 Brightness: 1.0 Clones: CRTC: 1 CRTCs: 0 1 2 ... HDMI2 connected 1280x1024+1280+0 (0x47) normal (normal left inverted right x axis y axis) 477mm x 268mm Identifier: 0x44 Timestamp: 51324 Subpixel: unknown Gamma: 1.0:1.0:1.0 Brightness: 1.0 Clones: CRTC: 2 CRTCs: 0 1 2 Below command fails: xrandr --output VGA1 --auto --output HDMI2 --auto --left-of VGA1 --output HDMI1 --auto --left-of HDMI2 Below command passes: xrandr --output VGA1 --auto --output HDMI2 --mode 1280x1024 --rate 60.0 --left-of VGA1 --output HDMI1 --auto --left-of HDMI2 Graphic card VGA compatible controller: Intel Corporation Ivy Bridge Graphics Controller (rev 09)

    Read the article

  • iCloud backup merges or overwrites?

    - by Joe McMahon
    The following happened today (it was six AM my time, so yeah, I was dumb and dropped stitches in this process): A friend had a problem with her iPhone and needed to reset it. Unfortunately she did the reset while connected to iTunes and the restore process kicked in. In my sleepy state, I told her to go ahead. She did, and restored the most recent local (iTunes) backup (from July last year - she doesn't back up often, as she has an Air which is pretty full). During setup on the phone, she was prompted to merge data with the iCloud copy, and did so. There was no "restore from iCloud" prompt. Obviously I should have made sure she was disconnected from iTunes before she did the reset, or had her set it up as a new device and then restored from iCloud, but water under the bridge now. (Side question: could I have had her disconnect and then restart the phone again and avoid this whole process?) The question is: was the "merge" that happened in this process a true merge, or a replace? Her passwords for Mail were wrong, since they were the old ones from the old backup. If she does the wipe data and restore from iCloud, will she get her old SMSes and calendar entries back? Or did the merge decide that the phone, despite it being "old" was right and therefore the SMSes, calendar entries, etc. were discarded? As a recovery option, I have a 4-day-old iTunes backup here from ~/Library/Application Support/MobileSync/Backup, but she and the phone are 3000 miles away, and it's 8GB, so I can't easily restore it for her. I do have the option of encrypting it and mailing it on a data stick if the iCloud backup is now toast. Should she try the wipe and restore from the cloud (after backing up locally), or should I just get the more-recent backup in the mail? My goal is to get everything (especially the SMSes) back to the most recent version possible.

    Read the article

  • Installing ionCube on Windows 2008 64bit

    - by JoJo
    I've been trying to install ionCube onto my server but have not been having a lot of luck! My server is: Windows 2008 64bit PHP 5.3.14 Thread Safe disabled running as FastCGI In my PHP.ini I have : zend_extension="C:\Program Files (x86)\PHP\ext\ioncube_loader_win_5.2.dll" The path is correct. The DLL is from the x86 NONTS VC9 version of ionCube and PHP is using the MSVC9 (Visual C++ 2008) compiler though I have also tried using the x86 NONTS VC6 version of ionCube. I'm not getting any error but I'm also not getting ionCube when using phpinfo(): This program makes use of the Zend Scripting Language Engine: Zend Engine v2.3.0, Copyright (c) 1998-2012 Zend Technologies Apart from the mail application pools I have also set all the applications in the application pool in IIS7 to use 32bit mode. I don't know if FastCGI is running under 64 or 32 bit mode nor how to switch it or whether it would make a difference? I know it can be a problem installing ionCube onto 64bit Windows but I have also come across threads whereby other people have also [somehow] managed to get it working but even though I seem to be doing the same as them I still can't get it working.

    Read the article

  • High-performance Academic Server [closed]

    - by PHPsmith
    Suppose I want to build a server for the university's academic interests. The server is dedicated only to a site, where users (students and lecturers) just view and fill the academic data. But at a time (e.g. once a semester), about 12,000 students will access the site simultaneously. Due to limitation of resources, I have to build the server using free software (except for the operating system Windows 7, the university has been prepared). The hardware is also limited to the usual 4-core computers (eg, Ivy Bridge Intel Core i7-3770) with approximately 16GB of memory (DDR3 1600 MHz), equipped with an RJ-45 port (Intel 82 579 Gigabit Ethernet). With all these limitations, I have to choose the software (web server, database, etc) are appropriate for this purpose is achieved. I decided to create a site in PHP. Please help me by answering the following questions based on your expertise. (my prime candidate software to consider after googling) Web server which is faster & stable & secure, when implemented and optimized for PHP? And why? (nginx) PHP accelerator which is faster & stable & compatible with the selected web server? And why? (APC with Zend Optimizer+) Database which is faster & stable & secure, when implemented and optimized for selected web server and selected PHP accelerator? (MySQL) Are there any errors that have been or will be happening from my condition is? If there is, please enlighten me? Is there anything else I need to know in order to achieve this goal? If there is, please enlighten me? I understand that the performance also depends on the implementation of source-code program, so I assume it will create a site with the best efficiency (e.g. using AJAX).

    Read the article

  • KVM virtual machine unable to access internet

    - by peachykeen
    I have KVM set up to run a virtual machine (Windows Home Server 2011 acting as a build agent) on a dedicated server (CentOS 6.3). Recently, I ran updates on the host, and the virtual machine is now unable to connect to the internet. The virtual network is running through NAT, the host has an interface (eth0:0) set up with a static IP (virt-manager shows the network and its IP correctly), and all connections to that IP should be sent to the guest. The host and guest can ping one another, but the guest cannot ping anything above the host, nor can I ping the guest from anywhere else (I can ping the host). Results from the guest to another server under my control and from an external system to the guest both return "Destination port unreachable". Running tcpdump on the host and destination shows the host replying to the ping, but the destination never sees it (it doesn't even look like the host is bothering to send it on at all, which leads me to suspect iptables). The ping output matches that, listing replies from 192.168.100.1. The guest can resolve DNS, however, which I find rather odd. The guest's network settings (connection TCP/IPv4 properties) are set up with a static local IP (192.168.100.128), mask of 255.255.255.0, and gateway and DNS at 192.168.100.1. When originally setting up the vm/net, I had set up some iptables rules to enable bridging, but after my hosting company complained about the bridge, I set up a new virtual net using NAT and believe I removed all the rules. The VM's network was working perfectly fine for the last few months, until yesterday. I haven't heard anything from the hosting company, didn't change anything on the guest, so as far as I know, nothing else has changed (unfortunately the list of packages updated has since fallen off scrollback and I didn't note it down).

    Read the article

  • Xen virtual host can reach some sites but not others

    - by Tun H S Lee
    Okay, this is killing me. Debian Squeeze, Xen 4.0, brand new install. No iptables rules whatsoever except for the ones added by the default xen bridge script. Dom0 can reach the entire world, no problems. DomU can receive packets from some hosts, but not from others. For instance, if I ping Host A, it works fine. If I ping Host B, the DomU reports 100% packet loss. The hosts are random, but consistent (even after reboots). I can see no pattern to why some work and others don't. In fact, in some cases, different virtual hosts on the same server (an other server at a different data center) are divided; some work and others do not. I can reboot (DomU or Dom0 too) and the same hosts will work or fail as before. If I tcpdump on the Host B while pinging from the DomU, everything looks fine. It sees the echo request coming in and says it's sending one back. However, if I tcpdump peth0 on the Dom0, it never sees the echo reply. Any ideas what could be happening? I'm tearing my hair out here.

    Read the article

< Previous Page | 131 132 133 134 135 136 137 138 139 140 141 142  | Next Page >