Search Results

Search found 34265 results on 1371 pages for 'oracle advanced computer science'.

Page 142/1371 | < Previous Page | 138 139 140 141 142 143 144 145 146 147 148 149  | Next Page >

  • Computer Vision and AR libraries availabe for Android?!?!?

    - by Arturo
    Hello I am starting out as an Android Developer, and I would like to know if there are any Computer vision libraries or Augmented Reality libraries for the Android SDK , as I am planning to use these libraries for a mobile app. I have read that if I download the NDK, I might be able to "import/use" the C openCV, and ARtoolkit libraries, but I am wondering if this is possible, or if there is a better and easier way of using these tools. Android apps are programmed in Java, yet OpenCV & ARtoolkit use C/C++, any way to use these libraries?!? Thank you!

    Read the article

  • Simple way to implement computer-go board in Java

    - by codingbear
    I want to make a simple Go board to design an Computer Go game. In a go game, you lie a "stone" (white or black) on a position where horizontal and vertical lines intersect. What are some simple ways to restrict users from placing their stones in other locations? Maybe I'm just not seeing a simple solution. EDIT I guess I should rephrase my question better: I want to know how to do the background image of Go board, so that I can lie my stones on the intersection of the horizontal and the vertical lines. I was thinking about getting a just regular Go board image, and when I'm actually rendering stones, I find right position of pixels to lie stones. However, that solution did not seem to be the best solution, since I need to worry about size of stone images and think about proportionality when I either expand or shrink the board window.

    Read the article

  • Computer Vision Website Image Slideshow help

    - by msandbot
    Hi, I'm making an online display of the output of a computer vision algorithm. After running the algorithm I am left with a folder of about 1000 16 bit .tiff files. I need to put those on the website in a list for so that the researchers can click through and find the list. Also there needs to be an image frame with an "animated gif" feel that can be started stopped and played in reverse. Any ideas on the best way to do this? What language to use? I made a simple website in Ruby on Rails but I don't know if it has the capabilities to do what I require.

    Read the article

  • On checking kernel parms HP-UX & Oracle 10.2

    - by [email protected]
    Hi,Just did this little script for a customer wanting to investigate if the kernel parameters of their HP-UX machines fits or not the Oracle 10.2 specifications ( looks like someone checked the "User Verified" at database installation time on some prerequisites)Just want to share ( its in Spanish)Hope it helps!--L Normal 0 21 false false false MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman"; mso-ansi-language:#0400; mso-fareast-language:#0400; mso-bidi-language:#0400;} ### ### check_kernel_parms.sh ### ### ### ###    NAME ###      check_kernel_parms.sh ### ###    DESCRIPTION ###      Comprueba los parametros de kernel ### ###    NOTES ###     Valido para versiones de SO HP-UX y Oracle 10.2 ###     ### ###    MODIFIED   (MM/DD/YY) ###    lvelasco    05/20/10 - Creacion     V_DATE=`/usr/bin/date +%Y%m%d_%H%M%S` if [ "${1}" != 'sin_traza' ]; then   V_FICHERO_LOG=`dirname $0`/`basename $0`.${V_DATE}.log   exec 4>&1   tee ${V_FICHERO_LOG} >&4 |&   exec 1>&p 2>&1 fi   echo "${V_DATE}- check_params.sh *******************************************" echo "Comenzado ejecucion de chequeo de parametros de kernel en maquina `hostname`" echo "****************************************************************************"   UX_VERS=`uname -a | awk '{print $3}'` KCTUNE=/usr/sbin/kctune MEM_TOTAL_MB=`./check_mem` <-- This should return the physical mem of the machine on bytes MEM_TOTAL=$((MEM_TOTAL_MB*1024))     NPROC=$(${KCTUNE} | grep nproc | grep -v '(nproc' | grep -v *nproc | awk '{print $2}') if [ ${NPROC} -lt 4096 ] then        echo "[FAILED] Information: El parametro nproc con valor actual ${NPROC} debe tener una valor superior a 4096" else        echo "[OK] Information: El parametro nproc con valor actual ${NPROC} debe tener una valor superior a 4096" fi     KSI_ALLOC_MAX_T=$(${KCTUNE} | grep ksi_alloc | awk '{print $2}') KSI_ALLOC_MAX=$((NPROC*8)) if [ ${KSI_ALLOC_MAX_T} -lt ${KSI_ALLOC_MAX} ] then        echo "[FAILED] Information: El parametro ksi_alloc_max con valor actual ${KSI_ALLOC_MAX_T} debe tener una valor superior a ${KSI_ALLOC_MAX}" else        echo "[OK] Information: El parametro ksi_alloc_max con valor actual ${KSI_ALLOC_MAX_T} debe tener una valor superior a ${KSI_ALLOC_MAX}" fi       EXECUTABLE_STACK=$(${KCTUNE} | grep executable_stack | awk '{print $2}') if [ ${EXECUTABLE_STACK} -ne 0 ] then        echo "[FAILED] Information: El parametro executable_stack con valor actual ${EXECUTABLE_STACK} debe tener una valor igual a 0" else        echo "[OK] Information: El parametro executable_stack con valor actual ${EXECUTABLE_STACK} debe tener una valor igual a 0" fi       MAX_THREAD_PROC=$(${KCTUNE} | grep max_thread_proc | awk '{print $2}') if [ ${MAX_THREAD_PROC} -lt 1024 ] then        echo "[FAILED] Information: El parametro max_thread_proc con valor actual ${MAX_THREAD_PROC} debe tener una valor superior a 1024" else        echo "[OK] Information: El parametro max_thread_proc con valor actual ${MAX_THREAD_PROC} debe tener una valor superior a 1024" fi     MAXDSIZ=$(${KCTUNE} | grep 'maxdsiz ' | awk '{print $2}') if [ ${MAXDSIZ} -lt 1073741824 ] then        echo "[FAILED] Information: El parametro maxdsiz con valor actual ${MAXDSIZ} debe tener una valor superior a 1073741824" else        echo "[OK] Information: El parametro maxdsiz con valor actual ${MAXDSIZ} debe tener una valor superior a 1073741824" fi     MAXDSIZ_64BIT=$(${KCTUNE} | grep maxdsiz_64bit | awk '{print $2}') if [ ${MAXDSIZ} -lt 2147483648 ] then        echo "[FAILED] Information: El parametro maxdsiz_64bit con valor actual ${MAXDSIZ_64BIT} debe tener una valor superior a 2147483648" else        echo "[OK] Information: El parametro maxdsiz_64bit con valor actual ${MAXDSIZ_64BIT} debe tener una valor superior a 2147483648" fi   MAXSSIZ=$(${KCTUNE} | grep 'maxssiz ' | awk '{print $2}') if [ ${MAXSSIZ} -lt 134217728 ] then        echo "[FAILED] Information: El parametro maxssiz con valor actual ${MAXSSIZ} debe tener una valor superior a 134217728" else        echo "[OK] Information: El parametro maxssiz con valor actual ${MAXSSIZ} debe tener una valor superior a 134217728" fi     MAXSSIZ_64BIT=$(${KCTUNE} | grep maxssiz_64bit | awk '{print $2}') if [ ${MAXSSIZ} -lt 1073741824 ] then        echo "[FAILED] Information: El parametro maxssiz_64bit con valor actual ${MAXSSIZ} debe tener una valor superior a 1073741824" else        echo "[OK] Information: El parametro maxssiz_64bit con valor actual ${MAXSSIZ} debe tener una valor superior a 1073741824" fi     MAXUPRC_T=$(${KCTUNE} | grep maxuprc | awk '{print $2}') MAXUPRC=$(((NPROC*9)/10)) if [ ${MAXUPRC_T} -lt ${MAXUPRC} ] then        echo "[FAILED] Information: El parametro maxuprc con valor actual ${MAXUPRC_T} debe tener una valor superior a ${MAXUPRC}" else        echo "[OK] Information: El parametro maxuprc con valor actual ${MAXUPRC_T} debe tener una valor superior a ${MAXUPRC}" fi   MSGMNI=$(${KCTUNE} | grep msgmni | awk '{print $2}') if [ ${MSGMNI} -lt ${NPROC} ] then        echo "[FAILED] Information: El parametro msgni con valor actual ${MSGMNI} debe tener una valor superior a ${NPROC}" else        echo "[OK] Information: El parametro msgni con valor actual ${MSGMNI} debe tener una valor superior a ${NPROC}" fi     if [ ${UX_VERS} = "B.11.23" ] then        MSGSEG=$(${KCTUNE} | grep msgseg | awk '{print $2}')        if [ ${MSGSEG} -lt 32767 ]        then        echo "[FAILED] Information: El parametro msgseg con valor actual ${MSGSEG} debe tener una valor superior a 32767"        else        echo "[OK] Information: El parametro msgseg con valor actual ${MSGSEG} debe tener una valor superior a 32767"        fi fi   MSGTQL=$(${KCTUNE} | grep msgtql | awk '{print $2}') if [ ${MSGTQL} -lt ${NPROC} ] then        echo "[FAILED] Information: El parametro msgtql con valor actual ${MSGTQL} debe tener una valor superior a ${NPROC}" else        echo "[OK] Information: El parametro msgtql con valor actual ${MSGTQL} debe tener una valor superior a ${NPROC}" fi       if [ ${UX_VERS} = "B.11.23" ] then        NFILE_T=$(${KCTUNE} | grep nfile | awk '{print $2}')        NFILE=$((15*NPROC+2048))        if [ ${NFILE_T} -lt ${NFILE} ]        then        echo "[FAILED] Information: El parametro nfile con valor actual ${NFILE_T} debe tener una valor superior a ${NFILE}"        else        echo "[OK] Information: El parametro nfile con valor actual ${NFILE_T} debe tener una valor superior a ${NFILE}"        fi fi     NFLOCKS=$(${KCTUNE} | grep nflocks | awk '{print $2}') if [ ${NFLOCKS} -lt ${NPROC} ] then        echo "[FAILED] Information: El parametro nflocks con valor actual ${NFLOCKS} debe tener una valor superior a ${NPROC}" else        echo "[OK] Information: El parametro nflocks con valor actual ${NFLOCKS} debe tener una valor superior a ${NPROC}" fi   NINODE_T=$(${KCTUNE} | grep ninode | grep -v vx | awk '{print $2}') NINODE=$((8*NPROC+2048)) if [ ${NINODE_T} -lt ${NINODE} ] then        echo "[FAILED] Information: El parametro ninode con valor actual ${NINODE_T} debe tener una valor superior a ${NINODE}" else        echo "[OK] Information: El parametro ninode con valor actual ${NINODE_T} debe tener una valor superior a ${NINODE}" fi     NCSIZE_T=$(${KCTUNE} | grep ncsize | awk '{print $2}') NCSIZE=$((NINODE+1024)) if [ ${NCSIZE_T} -lt ${NCSIZE} ] then        echo "[FAILED] Information: El parametro ncsize con valor actual ${NCSIZE_T} debe tener una valor superior a ${NCSIZE}" else        echo "[OK] Information: El parametro ncsize con valor actual ${NCSIZE_T} debe tener una valor superior a ${NCSIZE}" fi     if [ ${UX_VERS} = "B.11.23" ] then        MSGMAP_T=$(${KCTUNE} | grep msgmap | awk '{print $2}')        MSGMAP=$((MSGTQL+2))        if [ ${MSGMAP_T} -lt ${MSGMAP} ]        then        echo "[FAILED] Information: El parametro msgmap con valor actual ${MSGMAP_T} debe tener una valor superior a ${MSGMAP}"        else        echo "[OK] Information: El parametro msgmap con valor actual ${MSGMAP_T} debe tener una valor superior a ${MSGMAP}"        fi fi   NKTHREAD_T=$(${KCTUNE} | grep nkthread | awk '{print $2}') NKTHREAD=$((((NPROC*7)/4)+16)) if [ ${NKTHREAD_T} -lt ${NKTHREAD} ] then        echo "[FAILED] Information: El parametro nkthread con valor actual ${NKTHREAD_T} debe tener una valor superior a ${NKTHREAD}" else        echo "[OK] Information: El parametro nkthread con valor actual ${NKTHREAD_T} debe tener una valor superior a ${NKTHREAD}" fi     SEMMNI=$(${KCTUNE} | grep semmni | grep -v '(semm' | awk '{print $2}') if [ ${SEMMNI} -lt ${NPROC} ] then        echo "[FAILED] Information: El parametro semmni con valor actual ${SEMMNI} debe tener una valor superior a ${NPROC}" else        echo "[OK] Information: El parametro semmni con valor actual ${SEMMNI} debe tener una valor superior a ${NPROC}" fi     SEMMNS_T=$(${KCTUNE} | grep semmns | awk '{print $2}') SEMMNS=$((SEMMNI+2)) if [ ${SEMMNS_T} -lt ${SEMMNI} ] then        echo "[FAILED] Information: El parametro semmns con valor actual ${SEMMNS_T} debe tener una valor superior a ${SEMMNS}" else        echo "[OK] Information: El parametro semmns con valor actual ${SEMMNS_T} debe tener una valor superior a ${SEMMNS}" fi   SEMMNU_T=$(${KCTUNE} | grep semmnu | awk '{print $2}') SEMMNU=$((NPROC-4)) if [ ${SEMMNU_T} -lt ${SEMMNU} ] then        echo "[FAILED] Information: El parametro semmnu con valor actual ${SEMMNU_T} debe tener una valor superior a ${SEMMNU}" else        echo "[OK] Information: El parametro semmnu con valor actual ${SEMMNU_T} debe tener una valor superior a ${SEMMNU}" fi     if [ ${UX_VERS} = "B.11.23" ] then        SEMVMX=$(${KCTUNE} | grep msgseg | awk '{print $2}')        if [ ${SEMVMX} -lt 32767 ]        then        echo "[FAILED] Information: El parametro semvmx con valor actual ${SEMVMX} debe tener una valor superior a 32767"        else        echo "[OK] Information: El parametro semvmx con valor actual ${SEMVMX} debe tener una valor superior a 32767"        fi fi     SHMMNI=$(${KCTUNE} | grep shmmni | awk '{print $2}') if [ ${SHMMNI} -lt 512 ] then        echo "[FAILED] Information: El parametro shmmni con valor actual ${SHMMNI} debe tener una valor superior a 512" else        echo "[OK] Information: El parametro shmmni con valor actual ${SHMMNI} debe tener una valor superior a 512" fi     SHMSEG=$(${KCTUNE} | grep shmseg | awk '{print $2}') if [ ${SHMSEG} -lt 120 ] then        echo "[FAILED] Information: El parametro shmseg con valor actual ${SHMSEG} debe tener una valor superior a 120" else        echo "[OK] Information: El parametro shmseg con valor actual ${SHMSEG} debe tener una valor superior a 120" fi   VPS_CEILING=$(${KCTUNE} | grep vps_ceiling | awk '{print $2}') if [ ${VPS_CEILING} -lt 64 ] then        echo "[FAILED] Information: El parametro vps_ceiling con valor actual ${VPS_CEILING} debe tener una valor superior a 64" else        echo "[OK] Information: El parametro vps_ceiling con valor actual ${VPS_CEILING} debe tener una valor superior a 64" fi   SHMMAX=$(${KCTUNE} | grep shmmax | awk '{print $2}') if [ ${SHMMAX} -lt ${MEM_TOTAL} ] then         echo "[FAILED] Information: El parametro shmmax con valor actual ${SHMMAX} debe tener una valor superior a ${MEM_TOTAL}" else         echo "[OK] Information: El parametro shmmax con valor actual ${SHMMAX} debe tener una valor superior a ${MEM_TOTAL}" fi exit 0  

    Read the article

  • It’s On! Oracle Open World 2012 Opens Call for Papers is Open

    - by David Hope-Ross
    Oracle OpenWorld is among the world’s largest industry events for good reason. It offers a vast array of learning and networking opportunities in one of the planet’s great cities.  And one of the key reasons for its popularity among procurement and supply chain professionals is the prominence of presentations by customers.   If you’d like to deliver a presentation based on your experience, now is the time to submit your abstract for review by the selection panel. The competition is strong: roughly 18% of entries are accepted each year from more than 3,000 submissions. Review panels are made up of experts both internal and external to Oracle. Successful submissions often (but not exclusively) focus on customer successes, how-tos, or best practices. What’s in it for you? Recognition, for one thing. Accepted sessions are publicized in the content catalog, which goes live in mid-June, and sessions given by external speakers often prove the most popular. Plus, accepted speakers get a complimentary pass to Oracle OpenWorld with access to all sessions and networking events- that could save you up to $2,595!   Be sure designate your session for inclusion in the correct track by selecting  “APPLICATIONS: Supply Chain Management” or “APPLICATIONS: Sourcing and Procurement” from the Primary Track drop down menu.   We look forward to seeing you in San Francisco!

    Read the article

  • Advanced TSQL Tuning: Why Internals Knowledge Matters

    - by Paul White
    There is much more to query tuning than reducing logical reads and adding covering nonclustered indexes.  Query tuning is not complete as soon as the query returns results quickly in the development or test environments.  In production, your query will compete for memory, CPU, locks, I/O and other resources on the server.  Today’s entry looks at some tuning considerations that are often overlooked, and shows how deep internals knowledge can help you write better TSQL. As always, we’ll need some example data.  In fact, we are going to use three tables today, each of which is structured like this: Each table has 50,000 rows made up of an INTEGER id column and a padding column containing 3,999 characters in every row.  The only difference between the three tables is in the type of the padding column: the first table uses CHAR(3999), the second uses VARCHAR(MAX), and the third uses the deprecated TEXT type.  A script to create a database with the three tables and load the sample data follows: USE master; GO IF DB_ID('SortTest') IS NOT NULL DROP DATABASE SortTest; GO CREATE DATABASE SortTest COLLATE LATIN1_GENERAL_BIN; GO ALTER DATABASE SortTest MODIFY FILE ( NAME = 'SortTest', SIZE = 3GB, MAXSIZE = 3GB ); GO ALTER DATABASE SortTest MODIFY FILE ( NAME = 'SortTest_log', SIZE = 256MB, MAXSIZE = 1GB, FILEGROWTH = 128MB ); GO ALTER DATABASE SortTest SET ALLOW_SNAPSHOT_ISOLATION OFF ; ALTER DATABASE SortTest SET AUTO_CLOSE OFF ; ALTER DATABASE SortTest SET AUTO_CREATE_STATISTICS ON ; ALTER DATABASE SortTest SET AUTO_SHRINK OFF ; ALTER DATABASE SortTest SET AUTO_UPDATE_STATISTICS ON ; ALTER DATABASE SortTest SET AUTO_UPDATE_STATISTICS_ASYNC ON ; ALTER DATABASE SortTest SET PARAMETERIZATION SIMPLE ; ALTER DATABASE SortTest SET READ_COMMITTED_SNAPSHOT OFF ; ALTER DATABASE SortTest SET MULTI_USER ; ALTER DATABASE SortTest SET RECOVERY SIMPLE ; USE SortTest; GO CREATE TABLE dbo.TestCHAR ( id INTEGER IDENTITY (1,1) NOT NULL, padding CHAR(3999) NOT NULL,   CONSTRAINT [PK dbo.TestCHAR (id)] PRIMARY KEY CLUSTERED (id), ) ; CREATE TABLE dbo.TestMAX ( id INTEGER IDENTITY (1,1) NOT NULL, padding VARCHAR(MAX) NOT NULL,   CONSTRAINT [PK dbo.TestMAX (id)] PRIMARY KEY CLUSTERED (id), ) ; CREATE TABLE dbo.TestTEXT ( id INTEGER IDENTITY (1,1) NOT NULL, padding TEXT NOT NULL,   CONSTRAINT [PK dbo.TestTEXT (id)] PRIMARY KEY CLUSTERED (id), ) ; -- ============= -- Load TestCHAR (about 3s) -- ============= INSERT INTO dbo.TestCHAR WITH (TABLOCKX) ( padding ) SELECT padding = REPLICATE(CHAR(65 + (Data.n % 26)), 3999) FROM ( SELECT TOP (50000) n = ROW_NUMBER() OVER (ORDER BY (SELECT 0)) - 1 FROM master.sys.columns C1, master.sys.columns C2, master.sys.columns C3 ORDER BY n ASC ) AS Data ORDER BY Data.n ASC ; -- ============ -- Load TestMAX (about 3s) -- ============ INSERT INTO dbo.TestMAX WITH (TABLOCKX) ( padding ) SELECT CONVERT(VARCHAR(MAX), padding) FROM dbo.TestCHAR ORDER BY id ; -- ============= -- Load TestTEXT (about 5s) -- ============= INSERT INTO dbo.TestTEXT WITH (TABLOCKX) ( padding ) SELECT CONVERT(TEXT, padding) FROM dbo.TestCHAR ORDER BY id ; -- ========== -- Space used -- ========== -- EXECUTE sys.sp_spaceused @objname = 'dbo.TestCHAR'; EXECUTE sys.sp_spaceused @objname = 'dbo.TestMAX'; EXECUTE sys.sp_spaceused @objname = 'dbo.TestTEXT'; ; CHECKPOINT ; That takes around 15 seconds to run, and shows the space allocated to each table in its output: To illustrate the points I want to make today, the example task we are going to set ourselves is to return a random set of 150 rows from each table.  The basic shape of the test query is the same for each of the three test tables: SELECT TOP (150) T.id, T.padding FROM dbo.Test AS T ORDER BY NEWID() OPTION (MAXDOP 1) ; Test 1 – CHAR(3999) Running the template query shown above using the TestCHAR table as the target, we find that the query takes around 5 seconds to return its results.  This seems slow, considering that the table only has 50,000 rows.  Working on the assumption that generating a GUID for each row is a CPU-intensive operation, we might try enabling parallelism to see if that speeds up the response time.  Running the query again (but without the MAXDOP 1 hint) on a machine with eight logical processors, the query now takes 10 seconds to execute – twice as long as when run serially. Rather than attempting further guesses at the cause of the slowness, let’s go back to serial execution and add some monitoring.  The script below monitors STATISTICS IO output and the amount of tempdb used by the test query.  We will also run a Profiler trace to capture any warnings generated during query execution. DECLARE @read BIGINT, @write BIGINT ; SELECT @read = SUM(num_of_bytes_read), @write = SUM(num_of_bytes_written) FROM tempdb.sys.database_files AS DBF JOIN sys.dm_io_virtual_file_stats(2, NULL) AS FS ON FS.file_id = DBF.file_id WHERE DBF.type_desc = 'ROWS' ; SET STATISTICS IO ON ; SELECT TOP (150) TC.id, TC.padding FROM dbo.TestCHAR AS TC ORDER BY NEWID() OPTION (MAXDOP 1) ; SET STATISTICS IO OFF ; SELECT tempdb_read_MB = (SUM(num_of_bytes_read) - @read) / 1024. / 1024., tempdb_write_MB = (SUM(num_of_bytes_written) - @write) / 1024. / 1024., internal_use_MB = ( SELECT internal_objects_alloc_page_count / 128.0 FROM sys.dm_db_task_space_usage WHERE session_id = @@SPID ) FROM tempdb.sys.database_files AS DBF JOIN sys.dm_io_virtual_file_stats(2, NULL) AS FS ON FS.file_id = DBF.file_id WHERE DBF.type_desc = 'ROWS' ; Let’s take a closer look at the statistics and query plan generated from this: Following the flow of the data from right to left, we see the expected 50,000 rows emerging from the Clustered Index Scan, with a total estimated size of around 191MB.  The Compute Scalar adds a column containing a random GUID (generated from the NEWID() function call) for each row.  With this extra column in place, the size of the data arriving at the Sort operator is estimated to be 192MB. Sort is a blocking operator – it has to examine all of the rows on its input before it can produce its first row of output (the last row received might sort first).  This characteristic means that Sort requires a memory grant – memory allocated for the query’s use by SQL Server just before execution starts.  In this case, the Sort is the only memory-consuming operator in the plan, so it has access to the full 243MB (248,696KB) of memory reserved by SQL Server for this query execution. Notice that the memory grant is significantly larger than the expected size of the data to be sorted.  SQL Server uses a number of techniques to speed up sorting, some of which sacrifice size for comparison speed.  Sorts typically require a very large number of comparisons, so this is usually a very effective optimization.  One of the drawbacks is that it is not possible to exactly predict the sort space needed, as it depends on the data itself.  SQL Server takes an educated guess based on data types, sizes, and the number of rows expected, but the algorithm is not perfect. In spite of the large memory grant, the Profiler trace shows a Sort Warning event (indicating that the sort ran out of memory), and the tempdb usage monitor shows that 195MB of tempdb space was used – all of that for system use.  The 195MB represents physical write activity on tempdb, because SQL Server strictly enforces memory grants – a query cannot ‘cheat’ and effectively gain extra memory by spilling to tempdb pages that reside in memory.  Anyway, the key point here is that it takes a while to write 195MB to disk, and this is the main reason that the query takes 5 seconds overall. If you are wondering why using parallelism made the problem worse, consider that eight threads of execution result in eight concurrent partial sorts, each receiving one eighth of the memory grant.  The eight sorts all spilled to tempdb, resulting in inefficiencies as the spilled sorts competed for disk resources.  More importantly, there are specific problems at the point where the eight partial results are combined, but I’ll cover that in a future post. CHAR(3999) Performance Summary: 5 seconds elapsed time 243MB memory grant 195MB tempdb usage 192MB estimated sort set 25,043 logical reads Sort Warning Test 2 – VARCHAR(MAX) We’ll now run exactly the same test (with the additional monitoring) on the table using a VARCHAR(MAX) padding column: DECLARE @read BIGINT, @write BIGINT ; SELECT @read = SUM(num_of_bytes_read), @write = SUM(num_of_bytes_written) FROM tempdb.sys.database_files AS DBF JOIN sys.dm_io_virtual_file_stats(2, NULL) AS FS ON FS.file_id = DBF.file_id WHERE DBF.type_desc = 'ROWS' ; SET STATISTICS IO ON ; SELECT TOP (150) TM.id, TM.padding FROM dbo.TestMAX AS TM ORDER BY NEWID() OPTION (MAXDOP 1) ; SET STATISTICS IO OFF ; SELECT tempdb_read_MB = (SUM(num_of_bytes_read) - @read) / 1024. / 1024., tempdb_write_MB = (SUM(num_of_bytes_written) - @write) / 1024. / 1024., internal_use_MB = ( SELECT internal_objects_alloc_page_count / 128.0 FROM sys.dm_db_task_space_usage WHERE session_id = @@SPID ) FROM tempdb.sys.database_files AS DBF JOIN sys.dm_io_virtual_file_stats(2, NULL) AS FS ON FS.file_id = DBF.file_id WHERE DBF.type_desc = 'ROWS' ; This time the query takes around 8 seconds to complete (3 seconds longer than Test 1).  Notice that the estimated row and data sizes are very slightly larger, and the overall memory grant has also increased very slightly to 245MB.  The most marked difference is in the amount of tempdb space used – this query wrote almost 391MB of sort run data to the physical tempdb file.  Don’t draw any general conclusions about VARCHAR(MAX) versus CHAR from this – I chose the length of the data specifically to expose this edge case.  In most cases, VARCHAR(MAX) performs very similarly to CHAR – I just wanted to make test 2 a bit more exciting. MAX Performance Summary: 8 seconds elapsed time 245MB memory grant 391MB tempdb usage 193MB estimated sort set 25,043 logical reads Sort warning Test 3 – TEXT The same test again, but using the deprecated TEXT data type for the padding column: DECLARE @read BIGINT, @write BIGINT ; SELECT @read = SUM(num_of_bytes_read), @write = SUM(num_of_bytes_written) FROM tempdb.sys.database_files AS DBF JOIN sys.dm_io_virtual_file_stats(2, NULL) AS FS ON FS.file_id = DBF.file_id WHERE DBF.type_desc = 'ROWS' ; SET STATISTICS IO ON ; SELECT TOP (150) TT.id, TT.padding FROM dbo.TestTEXT AS TT ORDER BY NEWID() OPTION (MAXDOP 1, RECOMPILE) ; SET STATISTICS IO OFF ; SELECT tempdb_read_MB = (SUM(num_of_bytes_read) - @read) / 1024. / 1024., tempdb_write_MB = (SUM(num_of_bytes_written) - @write) / 1024. / 1024., internal_use_MB = ( SELECT internal_objects_alloc_page_count / 128.0 FROM sys.dm_db_task_space_usage WHERE session_id = @@SPID ) FROM tempdb.sys.database_files AS DBF JOIN sys.dm_io_virtual_file_stats(2, NULL) AS FS ON FS.file_id = DBF.file_id WHERE DBF.type_desc = 'ROWS' ; This time the query runs in 500ms.  If you look at the metrics we have been checking so far, it’s not hard to understand why: TEXT Performance Summary: 0.5 seconds elapsed time 9MB memory grant 5MB tempdb usage 5MB estimated sort set 207 logical reads 596 LOB logical reads Sort warning SQL Server’s memory grant algorithm still underestimates the memory needed to perform the sorting operation, but the size of the data to sort is so much smaller (5MB versus 193MB previously) that the spilled sort doesn’t matter very much.  Why is the data size so much smaller?  The query still produces the correct results – including the large amount of data held in the padding column – so what magic is being performed here? TEXT versus MAX Storage The answer lies in how columns of the TEXT data type are stored.  By default, TEXT data is stored off-row in separate LOB pages – which explains why this is the first query we have seen that records LOB logical reads in its STATISTICS IO output.  You may recall from my last post that LOB data leaves an in-row pointer to the separate storage structure holding the LOB data. SQL Server can see that the full LOB value is not required by the query plan until results are returned, so instead of passing the full LOB value down the plan from the Clustered Index Scan, it passes the small in-row structure instead.  SQL Server estimates that each row coming from the scan will be 79 bytes long – 11 bytes for row overhead, 4 bytes for the integer id column, and 64 bytes for the LOB pointer (in fact the pointer is rather smaller – usually 16 bytes – but the details of that don’t really matter right now). OK, so this query is much more efficient because it is sorting a very much smaller data set – SQL Server delays retrieving the LOB data itself until after the Sort starts producing its 150 rows.  The question that normally arises at this point is: Why doesn’t SQL Server use the same trick when the padding column is defined as VARCHAR(MAX)? The answer is connected with the fact that if the actual size of the VARCHAR(MAX) data is 8000 bytes or less, it is usually stored in-row in exactly the same way as for a VARCHAR(8000) column – MAX data only moves off-row into LOB storage when it exceeds 8000 bytes.  The default behaviour of the TEXT type is to be stored off-row by default, unless the ‘text in row’ table option is set suitably and there is room on the page.  There is an analogous (but opposite) setting to control the storage of MAX data – the ‘large value types out of row’ table option.  By enabling this option for a table, MAX data will be stored off-row (in a LOB structure) instead of in-row.  SQL Server Books Online has good coverage of both options in the topic In Row Data. The MAXOOR Table The essential difference, then, is that MAX defaults to in-row storage, and TEXT defaults to off-row (LOB) storage.  You might be thinking that we could get the same benefits seen for the TEXT data type by storing the VARCHAR(MAX) values off row – so let’s look at that option now.  This script creates a fourth table, with the VARCHAR(MAX) data stored off-row in LOB pages: CREATE TABLE dbo.TestMAXOOR ( id INTEGER IDENTITY (1,1) NOT NULL, padding VARCHAR(MAX) NOT NULL,   CONSTRAINT [PK dbo.TestMAXOOR (id)] PRIMARY KEY CLUSTERED (id), ) ; EXECUTE sys.sp_tableoption @TableNamePattern = N'dbo.TestMAXOOR', @OptionName = 'large value types out of row', @OptionValue = 'true' ; SELECT large_value_types_out_of_row FROM sys.tables WHERE [schema_id] = SCHEMA_ID(N'dbo') AND name = N'TestMAXOOR' ; INSERT INTO dbo.TestMAXOOR WITH (TABLOCKX) ( padding ) SELECT SPACE(0) FROM dbo.TestCHAR ORDER BY id ; UPDATE TM WITH (TABLOCK) SET padding.WRITE (TC.padding, NULL, NULL) FROM dbo.TestMAXOOR AS TM JOIN dbo.TestCHAR AS TC ON TC.id = TM.id ; EXECUTE sys.sp_spaceused @objname = 'dbo.TestMAXOOR' ; CHECKPOINT ; Test 4 – MAXOOR We can now re-run our test on the MAXOOR (MAX out of row) table: DECLARE @read BIGINT, @write BIGINT ; SELECT @read = SUM(num_of_bytes_read), @write = SUM(num_of_bytes_written) FROM tempdb.sys.database_files AS DBF JOIN sys.dm_io_virtual_file_stats(2, NULL) AS FS ON FS.file_id = DBF.file_id WHERE DBF.type_desc = 'ROWS' ; SET STATISTICS IO ON ; SELECT TOP (150) MO.id, MO.padding FROM dbo.TestMAXOOR AS MO ORDER BY NEWID() OPTION (MAXDOP 1, RECOMPILE) ; SET STATISTICS IO OFF ; SELECT tempdb_read_MB = (SUM(num_of_bytes_read) - @read) / 1024. / 1024., tempdb_write_MB = (SUM(num_of_bytes_written) - @write) / 1024. / 1024., internal_use_MB = ( SELECT internal_objects_alloc_page_count / 128.0 FROM sys.dm_db_task_space_usage WHERE session_id = @@SPID ) FROM tempdb.sys.database_files AS DBF JOIN sys.dm_io_virtual_file_stats(2, NULL) AS FS ON FS.file_id = DBF.file_id WHERE DBF.type_desc = 'ROWS' ; TEXT Performance Summary: 0.3 seconds elapsed time 245MB memory grant 0MB tempdb usage 193MB estimated sort set 207 logical reads 446 LOB logical reads No sort warning The query runs very quickly – slightly faster than Test 3, and without spilling the sort to tempdb (there is no sort warning in the trace, and the monitoring query shows zero tempdb usage by this query).  SQL Server is passing the in-row pointer structure down the plan and only looking up the LOB value on the output side of the sort. The Hidden Problem There is still a huge problem with this query though – it requires a 245MB memory grant.  No wonder the sort doesn’t spill to tempdb now – 245MB is about 20 times more memory than this query actually requires to sort 50,000 records containing LOB data pointers.  Notice that the estimated row and data sizes in the plan are the same as in test 2 (where the MAX data was stored in-row). The optimizer assumes that MAX data is stored in-row, regardless of the sp_tableoption setting ‘large value types out of row’.  Why?  Because this option is dynamic – changing it does not immediately force all MAX data in the table in-row or off-row, only when data is added or actually changed.  SQL Server does not keep statistics to show how much MAX or TEXT data is currently in-row, and how much is stored in LOB pages.  This is an annoying limitation, and one which I hope will be addressed in a future version of the product. So why should we worry about this?  Excessive memory grants reduce concurrency and may result in queries waiting on the RESOURCE_SEMAPHORE wait type while they wait for memory they do not need.  245MB is an awful lot of memory, especially on 32-bit versions where memory grants cannot use AWE-mapped memory.  Even on a 64-bit server with plenty of memory, do you really want a single query to consume 0.25GB of memory unnecessarily?  That’s 32,000 8KB pages that might be put to much better use. The Solution The answer is not to use the TEXT data type for the padding column.  That solution happens to have better performance characteristics for this specific query, but it still results in a spilled sort, and it is hard to recommend the use of a data type which is scheduled for removal.  I hope it is clear to you that the fundamental problem here is that SQL Server sorts the whole set arriving at a Sort operator.  Clearly, it is not efficient to sort the whole table in memory just to return 150 rows in a random order. The TEXT example was more efficient because it dramatically reduced the size of the set that needed to be sorted.  We can do the same thing by selecting 150 unique keys from the table at random (sorting by NEWID() for example) and only then retrieving the large padding column values for just the 150 rows we need.  The following script implements that idea for all four tables: SET STATISTICS IO ON ; WITH TestTable AS ( SELECT * FROM dbo.TestCHAR ), TopKeys AS ( SELECT TOP (150) id FROM TestTable ORDER BY NEWID() ) SELECT T1.id, T1.padding FROM TestTable AS T1 WHERE T1.id = ANY (SELECT id FROM TopKeys) OPTION (MAXDOP 1) ; WITH TestTable AS ( SELECT * FROM dbo.TestMAX ), TopKeys AS ( SELECT TOP (150) id FROM TestTable ORDER BY NEWID() ) SELECT T1.id, T1.padding FROM TestTable AS T1 WHERE T1.id IN (SELECT id FROM TopKeys) OPTION (MAXDOP 1) ; WITH TestTable AS ( SELECT * FROM dbo.TestTEXT ), TopKeys AS ( SELECT TOP (150) id FROM TestTable ORDER BY NEWID() ) SELECT T1.id, T1.padding FROM TestTable AS T1 WHERE T1.id IN (SELECT id FROM TopKeys) OPTION (MAXDOP 1) ; WITH TestTable AS ( SELECT * FROM dbo.TestMAXOOR ), TopKeys AS ( SELECT TOP (150) id FROM TestTable ORDER BY NEWID() ) SELECT T1.id, T1.padding FROM TestTable AS T1 WHERE T1.id IN (SELECT id FROM TopKeys) OPTION (MAXDOP 1) ; SET STATISTICS IO OFF ; All four queries now return results in much less than a second, with memory grants between 6 and 12MB, and without spilling to tempdb.  The small remaining inefficiency is in reading the id column values from the clustered primary key index.  As a clustered index, it contains all the in-row data at its leaf.  The CHAR and VARCHAR(MAX) tables store the padding column in-row, so id values are separated by a 3999-character column, plus row overhead.  The TEXT and MAXOOR tables store the padding values off-row, so id values in the clustered index leaf are separated by the much-smaller off-row pointer structure.  This difference is reflected in the number of logical page reads performed by the four queries: Table 'TestCHAR' logical reads 25511 lob logical reads 000 Table 'TestMAX'. logical reads 25511 lob logical reads 000 Table 'TestTEXT' logical reads 00412 lob logical reads 597 Table 'TestMAXOOR' logical reads 00413 lob logical reads 446 We can increase the density of the id values by creating a separate nonclustered index on the id column only.  This is the same key as the clustered index, of course, but the nonclustered index will not include the rest of the in-row column data. CREATE UNIQUE NONCLUSTERED INDEX uq1 ON dbo.TestCHAR (id); CREATE UNIQUE NONCLUSTERED INDEX uq1 ON dbo.TestMAX (id); CREATE UNIQUE NONCLUSTERED INDEX uq1 ON dbo.TestTEXT (id); CREATE UNIQUE NONCLUSTERED INDEX uq1 ON dbo.TestMAXOOR (id); The four queries can now use the very dense nonclustered index to quickly scan the id values, sort them by NEWID(), select the 150 ids we want, and then look up the padding data.  The logical reads with the new indexes in place are: Table 'TestCHAR' logical reads 835 lob logical reads 0 Table 'TestMAX' logical reads 835 lob logical reads 0 Table 'TestTEXT' logical reads 686 lob logical reads 597 Table 'TestMAXOOR' logical reads 686 lob logical reads 448 With the new index, all four queries use the same query plan (click to enlarge): Performance Summary: 0.3 seconds elapsed time 6MB memory grant 0MB tempdb usage 1MB sort set 835 logical reads (CHAR, MAX) 686 logical reads (TEXT, MAXOOR) 597 LOB logical reads (TEXT) 448 LOB logical reads (MAXOOR) No sort warning I’ll leave it as an exercise for the reader to work out why trying to eliminate the Key Lookup by adding the padding column to the new nonclustered indexes would be a daft idea Conclusion This post is not about tuning queries that access columns containing big strings.  It isn’t about the internal differences between TEXT and MAX data types either.  It isn’t even about the cool use of UPDATE .WRITE used in the MAXOOR table load.  No, this post is about something else: Many developers might not have tuned our starting example query at all – 5 seconds isn’t that bad, and the original query plan looks reasonable at first glance.  Perhaps the NEWID() function would have been blamed for ‘just being slow’ – who knows.  5 seconds isn’t awful – unless your users expect sub-second responses – but using 250MB of memory and writing 200MB to tempdb certainly is!  If ten sessions ran that query at the same time in production that’s 2.5GB of memory usage and 2GB hitting tempdb.  Of course, not all queries can be rewritten to avoid large memory grants and sort spills using the key-lookup technique in this post, but that’s not the point either. The point of this post is that a basic understanding of execution plans is not enough.  Tuning for logical reads and adding covering indexes is not enough.  If you want to produce high-quality, scalable TSQL that won’t get you paged as soon as it hits production, you need a deep understanding of execution plans, and as much accurate, deep knowledge about SQL Server as you can lay your hands on.  The advanced database developer has a wide range of tools to use in writing queries that perform well in a range of circumstances. By the way, the examples in this post were written for SQL Server 2008.  They will run on 2005 and demonstrate the same principles, but you won’t get the same figures I did because 2005 had a rather nasty bug in the Top N Sort operator.  Fair warning: if you do decide to run the scripts on a 2005 instance (particularly the parallel query) do it before you head out for lunch… This post is dedicated to the people of Christchurch, New Zealand. © 2011 Paul White email: @[email protected] twitter: @SQL_Kiwi

    Read the article

  • What's In Storage?

    - by [email protected]
    Oracle Flies South for Storage Networking Event Storage Networking World (now simply called SNW) is the place you'll find the most-comprehensive education on storage, infrastructure, and the datacenter in the spring of 2010. It's also the place where you'll see Oracle. During the April 12-15 event in Orlando, Florida, the industry's premiere presentations on storage trends and best practices are combined with hands-on labs covering storage management and IP storage. You'll also have the opportunity to learn about Oracle's Sun storage solutions, from Flash and open storage to enterprise disk and tape. Plus, if you stop by booth 207 in the expo hall, you might walk away with a bookish prize: an Amazon Kindle, courtesy of Oracle. Proving, once again, that education can be quite rewarding.

    Read the article

  • Week 15: The Telephone Game

    - by sandra.haan
    Have you ever played a game of telephone? Remember the one where you whispered something like "Once bitten, twice shy" to the person next to you, only to find that after this message has been shared around the circle the last person to repeat it says "Pastrami on Rye"? Messages can get distorted and we want to make sure that your past successes are clearly articulated which is why we have put in place a reference program for our partners. Listen in as Judson tells you how to engage with OPN in the Partner Reference program. Take advantage of the opportunity to promote your success to prospects through Oracle. Find out more and submit your nomination for a reference today. Until next time, The OPN Communications Team

    Read the article

  • Deploy ADF application to the Java Cloud on-demand training by Tom McGinn

    - by JuergenKress
    Learn how to use Oracle Enterprise Pack for Eclipse (OEPE) and SQL Developer to develop ADF applications using Oracle Java Cloud Service and Oracle Database Cloud Service. You see how to use Oracle SQL Developer to copy database schemas and data between a local Oracle database instance and Oracle Database Cloud Service. Then you see how to modify and deploy an Oracle Application Development Framework (Oracle ADF) application to Oracle Cloud by using Oracle Enterprise Pack for Eclipse (OEPE). Watch the on-demand training here. WebLogic Partner Community For regular information become a member in the WebLogic Partner Community please visit: http://www.oracle.com/partners/goto/wls-emea ( OPN account required). If you need support with your account please contact the Oracle Partner Business Center. Blog Twitter LinkedIn Mix Forum Wiki Technorati Tags: Java Cloud,Cloud,education,training,WebLogic,WebLogic Community,Oracle,OPN,Jürgen Kress,ADF

    Read the article

  • ODEE Green Field (Windows) Part 5 - Deployment and Validation

    - by AndyL-Oracle
    And here we are, almost finished with our installation of Oracle Documaker Enterprise Edition ("ODEE") in a Windows green field environment. Let's recap what we've done so far: In part 1, I went over the basic process that I intended to show with installing an ODEE on a green field server. I walked you through the basic installation of Oracle 11g database In part 2, I covered the installation of WebLogic application server. In part 3, I showed you how to install SOA Suite for WebLogic. In part 4, we did the first part of the installation of ODEE itself. What remains after all of that, is the deployment of the ODEE components onto the database and application server - so let's get to it! DATABASE First, we'll deploy the schemas to the database. The schemas are created during the ODEE installation according to the responses provided during the install process. To deploy the schemas, you'll need to login to the database server in your green field environment. Open a command line and CD into ODEE_HOME\documaker\database\oracle11g.Run SQLPLUS as SYSDBA and execute dmkr_admin.sql:  sqlplus / as sysdba @dmkr_admin.sql Execute dmkr_asline.sql, dmkr_admin_correspondence_example.sql.  If you require additional languages, run the appropriate SQL scripts (e.g. dmkr_asline_es.sql for Spanish). APPLICATION SERVER Next, we'll deploy the WebLogic domain and it's components - Documaker web services, Documaker Interactive, Documaker dashboard, and more. To deploy the components, you'll need to login to the application server in your green field environment. 1. Open Windows Explorer and navigate to ODEE_HOME\documaker\j2ee\weblogic\oracle11g\scripts.2. Using a text editor such as Notepad++, modify weblogic_installation_properties and set location of MIDDLEWARE_HOME and ODEE HOME. If you have used the defaults you’ll probably need to change the E: to C: and that’s it. Save the changes.3. Continuing in the same directory, use your text editor to modify set_middleware_env.cmd and set the drive and path to MIDDLEWARE_HOME. If you have used the defaults you’ll probably need to just change E: to C: and that’s it. Save the changes.4. In the same directory, execute wls_create_domain.cmd by double-clicking it. This should run to completion. If it does not, review any errors and correct them, and rerun the script.5. In the same directory, execute wls_add_correspondence.cmd by double-clicking it - again this should run to completion. 6. Next, we'll start the AdminServer - this is the main WebLogic domain server. To start it, use Windows Explorer and navigate to MIDDLEWARE_HOME\user_projects\domains\idocumaker_domain. Double-click startWebLogic.cmd and the server startup will begin. Once you see output that indicates that the server status changed to RUNNING you may proceed.  a. Note: if you saw database connection errors, you probably didn’t make sure your database name and connection type match. You can change this manually in the WebLogic Console. Open a browser and navigate to http://localhost:7001/console (replace localhost with the name of your application server host if you aren't opening the browser on the server), and login with the the weblogic credential you provided in the ODEE installation process. b. Once you're logged in, open Services?Data Sources. Select dmkr_admin and click Connection Pool.  c. The end of the URL should match the connection type you chose. If you chose ServiceName, the URL should be: jdbc:oracle:thin:@//<hostname>:1521/<serviceName> and if you chose SID, the URL should be: jdbc:oracle:thin:@//<hostname>:1521/<SIDname> d. An example serviceName is a fully qualified DNS-style name, e.g. "idmaker.us.oracle.com". (It does not need to actually resolve in DNS). An example SID is just a name, e.g. IDMAKER. e. Save the change and repeat for the data source dmkr_asline.  f. You will also need to make the same changes in the ODEE_HOME/documaker/docfactory/config/context/.bindings file - open the file in a text editor, locate the URL lines and make the appropriate change, then save the file.  7. Back in the ODEE_HOME\documaker\j2ee\weblogic\oracle11g\scripts directory, execute create_users_groups.cmd. 8. In the same directory, execute create_users_groups_correspondence_example.cmd. 9. Open a browser and navigate to http://localhost:7001/jpsquery. Replace localhost with the name of your application server host if you aren't running the browser on the application server. If you changed the default port for the AdminServer from 7001, use the port you changed it to. You should see output like this: 10. Start the WebLogic managed servers by opening a command prompt and navigating to MIDDLEWARE_HOME/user_projects/domains/idocumaker_domain/bin/. When you start the servers listed below, you will be prompted to enter the WebLogic credentials to start the server. You can prevent this by providing the credential in the startManagedwebLogic.cmd file for the WLS_USER and WLS_PASS values. Note that the credential will be stored in cleartext. To start the server, type in the command shown. a. Start the JMS Server: ./startManagedWebLogic.cmd jms_server b. Start Dashboard/Documaker Administrator: ./startManagedWebLogic.cmd dmkr_server c. Start Documaker Interactive for Correspondence: ./startManagedWebLogic.cmd idm_server SOA Composites  If you're planning on testing out the approval process components of BPEL that can be used with Documaker Interactive, then use the following steps to deploy the SOA composites. If you're not going to use BPEL, you can skip to the next section.1. Stop the servers listed in the previous section (Step 10) in the reverse order that they were started.2. Run the Domain configuration command: navigate to and execute MIDDLEWARE_HOME/wlserver_10.3/common/bin/config.cmd.3. Select Extend and click next. 4. Select the iDocumaker Domain and click Next. 5. Select the Oracle SOA Suite – 11.1.1.0 (this may automatically select other components which is OK). Click Next. 6. View the Configure JDBC resources screen. You should not make any changes. Click Next. 7. Check both connections and click Test Connections. After successful test, click Next. If the tests fail, something is broken. Go back to configure JDBC resources and check your service name/SID. 8. Check all schemas. Set a password (will be the same for all schemas). Enter the database information (service name, host name, port). Click Next. 9. Connections should test successfully. If not, go back and fix any errors. Click Next. 10. Click Next to pass through Optional Configuration. 11. Click Extend. 12. Click Done. 13. Open a terminal window and navigate to/execute: ODEE_HOME/documaker/j2ee/weblogic/oracle11g/bpel/antbuild.cmd14. Start the WebLogic Servers – AdminServer, jms_server, dmkr_server, idm_server. If you forgot how to do this, see the previous section Step 10. Note: if you previously changed the startManagedWebLogic.cmd script for WLS_USER and WLS_PASS you will need to make those changes again. 15. Start the WebLogic server soa_server1: MIDDLEWARE_HOME/user_projects/domains/idocumaker_domain/bin/startManagedWebLogic.cmd soa_server116. Open a browser to http://localhost:7001/console and login. 17. Navigate to Services?Data Sources and select DMKR_ASLINE. 18. Click the Targets tab. Check soa_server1, then click Save. Repeat for the DMKR_ADMIN data source. 19. Open a command prompt and navigate to ODEE_HOME/j2ee/weblogic/oracle11g/scripts, then execute deploy_soa.cmd. That's it! (As if that wasn't enough?) DOCUMAKER Deploy the sample MRL resources by navigating to/executing ODEE_HOME/documaker/mstrres/dmres/deploysamplemrl.bat. You should see approximately 500 resources deployed into the database. Start the Factory Services. Start?Run?services.msc. Locate the service named "ODDF xxxx" and right-click, select Start. Note that each Assembly Line has a separate Factory setup, including its own Factory service and Docupresentment service. The services are named for the assembly line and the machine on which they are installed (because you could have multiple machines servicing a single assembly line, so this allows for easy scripting to control all the services if you choose to do so. Repeat for the Docupresentment service. Note that each Assembly Line has a separate Docupresentment. Using Windows Explorer, navigate to ODEE_HOME/documaker/mstrres/dmres/input and select one of the XML files, and copy it into ODEE_HOME/documaker/hotdirectory. Note: if you chose a different hot directory during installation, copy the file there instead. Momentarily you should see the XML file disappear! Open browser and navigate to http://localhost:10001/DocumakerDashboard (previous versions 12.0-12.2 use http://localhost:10001/dashboard) and verify that job processed successfully. Note that some transactions may fail if you do not have a properly configured email server, and this is ok. You can set up a simple SMTP server (just search the internet for "SMTP developer" and you'll get several to choose from.  So... that's it? Where are we at this point? You now have a completely functional ODEE installation, from soup to nuts as they say. You can further expand your installation by doing some of the following activities: clustering WebLogic services configuring WebLogic for redundancy configuring Oracle 11g for RAC adding additional Factory servers for redundancy/processing capacity setting up a real MRL (instead of the sample resources) testing Documaker Web Services for job submission and more!  I certainly hope you've enjoyed this and find it useful. If you find yourself running into trouble, visit the Oracle Community for Documaker - there is plenty of activity there and you can ask questions. For more concentrated assistance, you can engage an Oracle consultant who is a subject matter expert to assist you. Feel free to email me [andy (dot) little (at) oracle (dot) com] and I can connect you with the appropriate resource to get started. Best of luck! -Andy 

    Read the article

  • Bajaj Electical Lites up India with Oracle SCM Apps!

    - by [email protected]
    The Executive Team from Bajaj Electricals/India did a fantastic job of summarizing their Oracle Experience in a 5 minute clip below. Their Chairman, Mr Baja, along with Ram/GM and several other business leaders highlighted the decision to select Oracle and Oracle consulting to connect thier business applications to meet the needs of a growing country.  Its a clip worth listening to and provides keen insight into both the vision and results. http://www.oracle.com/pls/ebn/live_viewer.main?p_direct=yes&p_shows_id=8226860

    Read the article

  • Alaska Airlines Takes Off with Siebel Loyalty and Marketing

    - by tony.berk
    Who likes junk mail? Not me! But I don't mind targeted messages that are relevant to me. Alaska Airlines greatly improved their ability to be more personal with their customers by replacing a legacy mainframe loyalty system with Siebel Loyalty and Siebel Marketing. Which means, as an Alaska Airlines customer, I get less junk mail! With improved access to customer profile information in Siebel, Alaska Airlines presents targeted, relevant offers on their website and via email. At the same time, Alaska Airlines has reduced their speed-to-market with promotions by 150 percent and can now implement new partner marketing programs twice as fast. Finally, as Steve Jarvis, VP of Marketing, Sales and Customer Experience at Alaska Airlines, points out in the video, Alaska Airlines can now reach all 22 million of their annual passengers, not just the 10% who were in the legacy loyalty system. To see other customer success stories, visit Siebel CRM Success. Click here to learn more about Oracle's CRM products.

    Read the article

  • Customer Centricity: It's Not Easy, But Worth It

    - by tony.berk
    Defining customer centricity is relatively easy: focusing on the customer and their experiences and interactions with your company. Implementing a customer centric strategy is not so easy. We've highlighted customers who have focused on their customers and experienced great success including SJ, the Swedish rail operator, and Vopak, the world's largest provider of conditioned storage facilities for bulk liquids. In this interview with Stuart Lennie, President, Volvo IT, North America and VP, Volvo's Global Sales to Order Solutions Unit, we get the opportunity to learn from another company that is not just talking about the customer, but actually implementing the significant strategic shifts required to become customer centric. Volvo has developed a vision, a strategy and a methodology to keep existing customers by understanding what is important to them. To see other customer success stories, visit Siebel CRM Success. Click here, to learn more about Oracle's CRM products.

    Read the article

  • New OTL Top Error Documents

    - by Oracle_EBS
    We would like to take this opportunity to announce new documents that are aimed at easing your experience when faced with troubleshooting Oracle Time and Labor issues. To this end we would like to highlight related and updated documentation regarding the top most reported OTL issues. Similar to the iRecruitment top error document updates announced in our EBS HCM Newsletter for December 2011, we proactively analyzed the issues reported on Oracle Time and Labor, identifying and consolidating knowledge content for the top 3 - 4 error messages in My Oracle Support documents. These new documents are as follows: Document Content Type Note ID: Oracle Time and Labor (OTL) Timekeeper issues Functional 1380612.1 Oracle Time and Labor (OTL) Approval issues Functional 1383990.1 Oracle Time and Labor (OTL) Retrieval issues Functional 1385426.1 These documents are now available via our Oracle Time and Labor Information Center Doc ID 1293475.1. As always, we very much welcome your feedback should you use these documents. Please add your views by using the "Rate This Document" feature should you wish to share your experience and any further improvement suggestions.

    Read the article

  • Cutting Subscriber Churn with Media Intelligence

    - by Oracle M&E
    There's lots of talk in media and entertainment companies about using "big data".  But it's often hard to see through the hype and understand how big data brings benefits in the real world.  How about being able to predict with 92% accuracy which subscribers intend to cancel their subscription - and put in place a renewal strategy to dramatically reduce that churn?  That's what Belgian media company De Persgroep has achieved with Oracle's Media Intelligence solution.  "One of the areas in which we're able to achieve beautiful results using big data is the churn prediction," De Persgroep's CIO Luc Verbist explains in a new Oracle video.  "Based on all the data that we collect on websites and all your behavior, payment behavior and so on, we're able to make a prediction model, which, with an accuracy of 92 percent, is able to predict that you probably won't renew your newspaper, anymore. So our approach to renewal is completely different to the people in that segment than towards the other people. And this has brought us a lot of value and a lot of customers who didn't stop their newspaper where else they would have done so." De Persgroep is using Oracle's Big Data Appliance, along with software from Oracle partner NGDATA to build up a detailed "DNA profile" of each individual customer, based on every interaction, in real time.  This means that any change in behavior - a drop in content consumption, a late subscription payment, a negative social media comment - is captured.  Applying advanced data modeling techniques automatically converts those raw interactions into data with real business meaning - like that customer's risk of churning. The very same data profile - comprising hundreds if individual dimensions - can simultaneously drive targeted marketing campaigns - informing audience about new content that's most relevant and encouraging them to subscribe.  It can power content recommendations and personalization right in the content sites and apps. And it can link directly into digital advertising networks via platforms like Oracle's BlueKai data management platform (DMP), to drive increased advertising CPMs. Using Oracle's Media Intelligence solution enables this across De Persgroep's business - comprising eight newspapers and 25 magazines published in Belgium and The Netherlands, and digital properties including websites with 6m daily unique visitors, along with TV and radio stations. "The company strategy is in fact a customer-centric strategy, so we want to get a 360-view about our customers, about our prospects. And the big data project helped us to achieve that goal," says Verbist. Using Oracle's Big Data Appliance to underpin the solution created huge savings.   "The selection of the Big Data Appliance was quite easy.  It was very quick to install, very easy to install, as well. And it was far cheaper than building our own Hadoop cluster. So it was in fact a non-brainer," Verbist explains. Applying Media Intelligence approach has yielded incredible results for De Persgroep, including: Improved products - with a new understanding of how readers are consuming print and digital content across the day Improved customer segmentation - driving a 6X improvement in customer prospecting and acquisition when contacting a specific segment Having the project up and running in three months And that has led to competitive benefits for De Persgroep, as Luc Verbist explains: "one of the results we saw since we started using big data is that we're able to increase the gap between we as the market leader, and the second [by] more than 20 percent."

    Read the article

  • Adatintegrációs rendezvény HOUG tagoknak, DW/BI és Database szakosztály

    - by user645740
    2011. június 29-én szerdán lesz a HOUG szervezet Oracle adatintegrációs rendezvénye. Részvételi feltétel: HOUG tagság! Ha HOUG tag, akkor azért jöjjön, ha Oracle felhasználó és még nem HOUG tag, akkor lépjen be gyorsan a HOUG egyesületbe! Témák: adatintegráció, ELT-ETL, OWB, ODI, GoldenGate, RAC, Active Data Guard, stb. Az Oracle Warehouse Buildernek sok felhasználója van Magyarországon, és nem csupán az adattárházas-BI környezetekben. Az ELT területen Oracle Data Integratorra fókuszál az Oracle, ami heterogén környezetekben kiválóan muködik, azaz nem csak Oracle adatbázisokkal. Katt ide: HOUG szervezet Oracle adatintegrációs rendezvénye.

    Read the article

  • Oracle Tutor: *** CAUTION to Word .docx Users ***

    - by [email protected]
    Microsoft released a security update KB969604 for Office 2007 (around June 2009) This update causes document variables within Word docx files to be scrambled. This update might still be pushed out via Office 2007 updates DO NOT save files as docx using MS OFFICE 2007 until you apply the MS hotfix # 970942 available here If you are using Windows XP with Office 2003 or Office 2000 and have installed an older Office 2007 compatibility pack, documents saved as docx may also cause the scrambled document variables. Installing the 2007 compatibility pack published on 1/6/2010 (version 4) will prevent the document variables from becoming corrupt. Those on Windows 2000 may not be able to install the latest compatibility pack, or the compatibility pack may not function properly. This situation will hopefully be rectified in the coming months. What is a document variable? Document variables store data inside the document, invisible to the user. The Tutor software uses them when converting the document to HTML and when creating the flowchart, just to name a couple of uses. How will you know if a document's variables are scrambled? The difficulty in diagnosing the issue is that the symptoms can take myriad forms. There isn't a single error message or a single feature that one can point to and say, "test for the problem by doing this." The best clue about the error is seeing any kind of string in an error message that has garbage characters, question marks, xml code snippets, or just nonsense. Such as "Language ?????????????xlr;lwlerkjl could not be found." It is also possible to see the corrupted data in the footers of the Word docs. And, just because the footers look correct does not mean that the document variables are not corrupted. The corruption problem does not occur in every document variable in the document, just some of them. Often it is less than a quarter of them. What is the difference between docx files and doc files? Office 2007 uses Office Open XML formats with .docx and .docm filename extensions. - Docx is an Office Open XML word document. - Docm is a macro enabled Office Open XML document. This means the file structure behind the scenes is quite different from the binary file formats used prior to Office 2007 such as .doc, .dot, .xls, and .ppt. Solution Summary: For Windows XP and Word 2007: Install the hotfix, or save files as *.doc For Windows XP and Word 2000 and 2003: Install the latest compatibility pack or save files as *.doc For Windows 2000 with Word 2000 or 2003, do not use any compatibility pack, save files as *.doc Emily Chorba Principle Product Manager for Oracle Tutor

    Read the article

  • BPM+SOA Governance Hands-On-Workshops 17.3. Hannover, 22.3. Hamburg, 24.3. Potsdam

    - by franziska.schneider(at)oracle.com
    Oracle Hands-on Workshop: Entdecken Sie die Flexibilität und Leistungsfähigkeit der BPM-Suite und dem Enterprise Repository. Geschäftprozessmodellierung (BPM) und -ausführung ist aufgrund leistungsfähiger und einfacher anzuwendender Tools für immer mehr Unternehmen eine sinnvolle Lösung. Ein wichtiger Aspekt dabei ist das reibungslose Zusammenspiel zwischen den Fachabteilungen und der Software-Entwicklung. Die Abstimmung zwischen der Fachabteilung, welche die Prozesse modelliert, und den Entwicklern, welche die Services bereitstellen, kann durch SOA-Governance Methodiken gesteuert werden. Dabei muss es nicht immer gleich ein umfassendes Governance-Modell sein, aber eine gewisse Abstimmung ist sinnvoll. In diesem Handson-Workshop soll ein gangbarer Mittelweg aufgezeigt werden. In den Workshops von Oracle können Sie sich mit Kollegen austauschen, sich die neueste Technik direkt von den Oracle Experten zeigen lassen und an praktischen Übungen teilnehmen. Auf dieser Veranstaltung sind Sie richtig, wenn Sie mit der Oracle BPM-Suite in die Modellierung von BPMN Geschäftsprozessen einsteigen möchten, das Oracle Enterprise Repository als zentrale Verwaltungsplattform kennenlernen möchten, lernen möchten, wie Sie Einblick in die Abhängigkeiten Ihrer SOA bekommen und wie Sie die Abstimmung zwischen IT und Fachbereich werkzeugunterstützt optimieren können. Nutzen Sie diese Chance, neue Kontakte zu knüpfen! Melden Sie sich hier gleich für die kostenlose Veranstaltung an.

    Read the article

  • Together at Last

    - by [email protected]
    OpenWorld, JavaOne, and Oracle Develop Get ready to converge on the ultimate IT convergence. Join us September 19-23 in San Francisco to attend Oracle OpenWorld, JavaOne, and Oracle Develop. With our new and complete technology stack apps-to-disk approach, there's something here for everyone. For all the nitty-gritty details, check out this recent article from Oracle Magazine. Better yet, reserve your place now on our registration page. We'll turn your visit to the city of the Golden Gate into a golden opportunity for your enterprise.

    Read the article

  • More Collateral to drive Remarketer Activity

    - by martin.morganti(at)oracle.com
    Over the last few months we have added a range of marketing materials to the Remarketer Level pages including an extensive set of Marketing Kits to support the Solution Kits previously available. As part of the continuing program, we have just added some additional training for Remarketers at no cost. In addition to the Oracle 1-Click Technology Products Guided Learning Path which explains about the program and how to position the products, we have added Oracle Database 11g 1-Click Technology Sales Guided Learning Path. This Learning path allows Remarketers to get access to more detailed training on the Oracle 11G database and so develop their understanding of the opportunities they could be benefiting from today, by reselling the 1-click products. This is in direct response to requests to make more training available to the Remarketers, so take the opportunity to let your Remarketer customers and prospects know about this additional training and how they can Jump Start a resell business with Oracle today with No Fees, No Barriers and No Excuses.

    Read the article

  • ODEE Green Field (Windows) Part 4 - Documaker

    - by AndyL-Oracle
    Welcome back! We're about nearing completion of our installation of Oracle Documaker Enterprise Edition ("ODEE") in a green field. In my previous post, I covered the installation of SOA Suite for WebLogic. Before that, I covered the installation of WebLogic, and Oracle 11g database - all of which constitute the prerequisites for installing ODEE. Naturally, if your environment already has a WebLogic server and Oracle database, then you can skip all those components and go straight for the heart of the installation of ODEE. The ODEE installation is comprised of two procedures, the first covers the installation, which is running the installer and answering some questions. This will lay down the files necessary to install into the tiers (e.g. database schemas, WebLogic domains, etcetera). The second procedure is to deploy the configuration files into the various components (e.g. deploy the database schemas, WebLogic domains, SOA composites, etcetera). I will segment my posts accordingly! Let's get started, shall we? Unpack the installation files into a temporary directory location. This should extract a zip file. Extract that zip file into the temporary directory location. Navigate to and execute the installer in Disk1/setup.exe. You may have to allow the program to run if User Account Control is enabled. Once the dialog below is displayed, click Next. Select your ODEE Home - inside this directory is where all the files will be deployed. For ease of support, I recommend using the default, however you can put this wherever you want. Click Next. Select the database type, database connection type – note that the database name should match the value used for the connection type (e.g. if using SID, then the name should be IDMAKER; if using ServiceName, the name should be “idmaker.us.oracle.com”). Verify whether or not you want to enable advanced compression. Note: if you are not licensed for Oracle 11g Advanced Compression option do not use this option! Terrible, terrible calamities will befall you if you do! Click Next. Enter the Documaker Admin user name (default "dmkr_admin" is recommended for support purposes) and set the password. Update the System name and ID (must be unique) if you want/need to - since this is a green field install you should be able to use the default System ID. The only time you'd change this is if you were, for some reason, installing a new ODEE system into an existing schema that already had a system. Click Next. Enter the Assembly Line user name (default "dmkr_asline" is recommended) and set the password. Update the Assembly Line name and ID (must be unique) if you want/need to - it's quite possible that at some point you will create another assembly line, in which case you have several methods of doing so. One is to re-run the installer, and in this case you would pick a different assembly line ID and name. Click Next. Note: you can set the DB folder if needed (typically you don’t – see ODEE Installation Guide for specifics. Select the appropriate Application Server type - in this case, our green field install is going to use WebLogic - set the username to weblogic (this is required) and specify your chosen password. This credential will be used to access the application server console/control panel. Keep in mind that there are specific criteria on password choices that are required by WebLogic, but are not enforced by the installer (e.g. must contain a number, must be of a certain length, etcetera). Choose a strong password. Set the connection information for the JMS server. Note that for the 12.3.x version, the installer creates a separate JVM (WebLogic managed server) that hosts the JMS server, whereas prior editions place the JMS server on the AdminServer.  You may also specify a separate URL to the JMS server in case you intend to move the JMS resources to a separate/different server (e.g. back to AdminServer). You'll need to provide a login principal and credentials - for simplicity I usually make this the same as the WebLogic domain user, however this is not a secure practice! Make your JMS principal different from the WebLogic principal and choose a strong password, then click Next. Specify the Hot Folder(s) (comma-delimited if more than one) - this is the directory/directories that is/are monitored by ODEE for jobs to process. Click Next. If you will be setting up an SMTP server for ODEE to send emails, you may configure the connection details here. The details required are simple: hostname, port, user/password, and the sender's address (e.g. emails will appear to be sent by the address shown here so if the recipient clicks "reply", this is where it will go). Click Next. If you will be using Oracle WebCenter:Content (formerly known as Oracle UCM) you can enable this option and set the endpoints/credentials here. If you aren't sure, select False - you can always go back and enable this later. I'm almost 76% certain there will be a post sometime in the future that details how to configure ODEE + WCC:C! Click Next. If you will be using Oracle UMS for sending MMS/text messages, you can enable and set the endpoints/credentials here. As with UCM, if you're not sure, don't enable it - you can always set it later. Click Next. On this screen you can change the endpoints for the Documaker Web Service (DWS), and the endpoints for approval processing in Documaker Interactive. The deployment process for ODEE will create 3 managed WebLogic servers for hosting various Documaker components (JMS, Interactive, DWS, Dashboard, Documaker Administrator, etcetera) and it will set the ports used for each of these services. In this screen you can change these values if you know how you want to deploy these managed servers - but for now we'll just accept the defaults. Click Next. Verify the installation details and click Install. You can save the installation into a response file if you need to (which might be useful if you want to rerun this installation in an unattended fashion). Allow the installation to progress... Click Next. You can save the response file if needed (e.g. in case you forgot to save it earlier!) Click Finish. That's it, you're done with the initial installation. Have a look around the ODEE_HOME that you just installed (remember we selected c:\oracle\odee_1?) and look at the files that are laid down. Don't change anything just yet! Stay tuned for the next segment where we complete and verify the installation. 

    Read the article

  • BI Publisher at OpenWorld 2012

    - by mdonohue
    For those going to OpenWorld, hope you can join us for any of the following Sessions, Hands On Labs or just stop by and visit us in the DEMOgrounds: Moscone South S-262 Oracle Business Intelligence Publisher Overview, What’s New, and What’s Planned Monday, 1-Oct 13:45 - 14:45Moscone South - 305Mike Donohue - Oraclewith Ed Farler - CSC Oracle Business Intelligence Publisher: Reporting for Oracle Applications Wednesday, 3-Oct 11:45 - 12:45Palace Hotel - RoseMike Donohue - OracleNote: new room to accommodate everyone who pre-registered Oracle Business Intelligence Publisher Best Practices: Be a Reporting Superstar Wednesday, 3-Oct 15:30 - 16:30Moscone South - 305Nikos Psomas & Klaus Fabian - Oracle Two sessions of the Hands on Lab:  Building Reports and Data Models in Oracle Business Intelligence Publisher Tuesday 2-Oct 17:00 - 18:00andThursday 4-Oct 11:15 - 12:15Marriott Marquis - Salon 5/6Nikos Psomas, Klaus Fabian & Kasturi Shekar -- Oracle You can also download the Focus on BI Publisher sheet that lists all Publisher related Sessions, Labs and DEMOground stations. Hope to see you there.

    Read the article

  • This week in the OTN Architect Center

    - by Bob Rhubart
    Updated every Monday, the Oracle Technology Network Architect Center is your one-stop for the latest content drawn from across the architect community. You find the articles and white papers, the latest ArchBeat Podcast, selected blog posts from community leaders, a list of events for architects, along with the latest information on Oracle products. Featured this week: A Fusion Applications Technical Overview A sample chapter from Managing Oracle Fusion Applications by Richard Bingham, new from Oracle Press. Oracle Optimized Solution for Lifecycle Content Management A new white paper from Donna Harland and Nick Kloski. Toronto Architect Day Panel Discussion - Part 2 The second of a four-part program featuring a live recording of the panel discussion from OTN Architect Day in Toronto, featuring Oracle ACE Director Cary Millsap, InfoQ.com editor and co-founder Floyd Marinescu, and members of Oracle's Enterprise Architecture team. Check it out: OTN Architect Center

    Read the article

  • What's On Tap for Tuesday

    - by Oracle OpenWorld Blog Team
     By Karen Shamban  What's on tap for Tuesday, October 2? Beside a visit or two to get a drink (coffee in the a.m., beer in the p.m.) at the Tap and Brew, that is?  Lots, of course. Registration Moscone West, Moscone South, Hilton San Francisco, 7:00 a.m. - 5:30 p.m. Westin St. Francis, 7:00 a.m. - 4:30 p.m. Oracle OpenWorld Keynote featuring Oracle Executive Vice President Thomas Kurian Moscone North Hall D, 8:00 a.m. - 9:45 a.m. Oracle OpenWorld Keynote featuring Oracle CEO Larry Ellison Moscone North Hall D, 2:45 p.m. - 4:30 p.m. Exhibition Halls Open Moscone North and Moscone West, 9:45 a.m. - 6:00 p.m. General Sessions Various times and locations Sessions, Demos, Labs, BOFs Various times and locations Oracle OpenWorld Music Festival Various times and locations Hope you're enjoying the conference, the networking, the energy, and the city!

    Read the article

  • Critical Patch Updates During EBS 11i Exception to Sustaining Support Period

    - by Elke Phelps (Oracle Development)
    As previously blogged in the EBS 11i and 12.1 Support Timeline Changes entry, two important changes to the Oracle Lifetime Support policies were announced at Oracle OpenWorld 2012 - San Francisco.  These changes affect E-Business Suite Releases 11i and 12.1. Critical Patch Updates for EBS 11i during the Exception to Sustaining Support Period You may be wondering about the availability of Critical Patch Updates (CPU) for EBS 11i during the Exception to Sustaining Support period.  The following details the E-Business Suite Critical Patch Update support policy for EBS 11i during the Exception to Sustaining Support period: Oracle will continue to provide CPUs containing critical security fixes for E-Business Suite 11i.  CPUs will be packaged and released as as cumulative patches for both ATG RUP 6 and ATG RUP 7. As always, we try to minimize the number of patches and dependencies required for uptake of a CPU; however, there have been quite a few changes to the 11i baseline since its release.  For dependency reasons the 11i CPUs may require a higher number of files in order to bring them up to a consistent, stable, and well tested level. EBS 11i customer will continue to receive CPUs up to and including the October 2014 CPU. Where can I learn more? There are two interlocking policies that affect the E-Business Suite:  Oracle's Lifetime Support policies for each EBS release (timelines which were updated by this announcement), and the Error Correction Support policies (which state the minimum baselines for new patches). For more information about how these policies interact, see: Understanding Support Windows for E-Business Suite Releases What about E-Business Suite technology stack components? Things get more complicated when one considers individual techstack components such as Oracle Forms or the Oracle Database.  To learn more about the interlocking EBS+techstack component support windows, see these two articles: On Apps Tier Patching and Support: A Primer for E-Business Suite Users On Database Patching and Support: A Primer for E-Business Suite Users Where can I learn more about Critical Patch Updates?The Critical Patch Update Advisory is the starting point for relevant information. It includes a list of products affected, pointers to obtain the patches, a summary of the security vulnerabilities, and links to other important documents.  Related Articles EBS 11i and 12.1 Support Timeline Changes Frequently Asked Questions about Latest EBS Support Changes Extended Support Fees Waived for E-Business Suite 11i and 12.0

    Read the article

< Previous Page | 138 139 140 141 142 143 144 145 146 147 148 149  | Next Page >