Search Results

Search found 15043 results on 602 pages for 'foundation framework'.

Page 143/602 | < Previous Page | 139 140 141 142 143 144 145 146 147 148 149 150  | Next Page >

  • Windows 7 Sub-Folders hidden in "Program Files" directory

    - by ron tornambe
    I have Google searched for an hour now and I am confounded. I am using InnoSetup to install a .NET Winforms application that creates directories and folders on the fly. (I have set the folder options to display hidden files, folders...) Although the files that are added to "created" folders appear within the application, they do not show when using Windows Explorer or even when issuing a Dir from a command prompt. I have also modified the application to display (and delete) the contents of these (seemingly imaginary) folders, so I am sure they exist. What am I missing?

    Read the article

  • Microsoft Blend 4 Crashes On Splash Screen [closed]

    - by Giora Ron Genender
    Recently I encountered a big problem: Blend 4 always crashes immediately after a splash screen ends. No error numbers mentioned, just a crash window saying "Blend has been crashed, debug or close". Is anybody else familiar with that problem? I tried to get some help from Google but there were no relevant references. I Clicked "Debug" and JIT Debugger was opened, it threw "FataExecutionEngineError" exception... What does it mean?

    Read the article

  • What happens if I run caspol.exe multiple times?

    - by Maclovin
    Hi there! Caspol.exe is used to modify security policy for the machine policy level, the user policy level, and the enterprise policy level. What I use it for, is setting up av trust between the client and an area on some server. I went through the scripts on the server, and found an interesting script that sets up full trust via caspol between a client in one zone, and an application on the server. That script has been running every day, for every logon, since it was implemented. Can someone tell me the consequences? I guess there is about 500 trusts between the client computer and the server, all which points to the same thing.

    Read the article

  • How to add quotes in visual basic? [on hold]

    - by Poistenec
    I'd like to ask how is it possible to add quotes in VB. I'm trying to run command which contains quotes.. example: Shell("cmd.exe") SendKeys.Send("cd "c:\users\abc def" ") <<<<--- this line SendKeys.Send("{ENTER}") there is an syntax error. the problem is that I need to add quotes to some commands as there is a space in folderpath. As a beginner in VB I'm not really sure how to describe the poblem correctly so I hope you can see the it in my example :/ Thank you all in advance

    Read the article

  • Is is possible to slipstream DotNet 4 into Windows XP ?

    - by user43300
    I tried to use nLite but this program is no longer updated. And it seems it has no capability of dealing with dotNet. On my instalation CD there is DOTNETFX folder with version 1.1, but it seems even this old version is not installed with system. I also read somewhere that it is possible to download dotNet as system update, that is a file with name that begins wih KB.... , so that file could be properly digested by nLite ? Any help in this matter ?

    Read the article

  • Virtual host Alias not routing properly

    - by Jacob
    I apologize if this question has been asked many times in the past. I am not 100% sure of the exact cause of my issue and am out of google magic right now. Basically I have a virtual host file setup with an Alias record that points to a different directory other the document root. It basically looks like this <VirtualHost *:80> ServerName iBusinessCentral.com ServerAdmin [email protected] DocumentRoot /var/www/marketingsites/ ServerAlias iBusinessCentral.com *.iBusinessCentral.com Alias /unsub "/var/www/unsub/site_index/" </VirtualHost> When I navigate to ibusinesscentral.com/unsub/?randomquerystring I am directed to the correct folder. If I remove the query string and navigate to ibusinesscentral.com/unsub/ I am taken to the directory in the document root. The unsub directory is a zend application and I need to be able to navigate to different url paths like ibusinesscentral.com/unsub/unenroll?querystring I have tried using AliasMatch instead of Alias. I have also tried adding a slash after the unsub portion of the Alias record, and have not had any luck to this point. Thanks in advance for any assistance

    Read the article

  • MSBuild: TlbImp error since upgrading to VS 2010

    - by floele
    Hi, since upgrading my project to VS2010, including the use of MSBuild v4 instead of 3.5 (and not making any other changes), I get the following build error and have no clue how to fix it (log from CC.NET): <target name="ResolveComReferences" success="false"> <message level="high"><![CDATA[C:\Programme\Microsoft SDKs\Windows\v7.0A\bin\TlbImp.exe c:\Assemblies\NMSDVDXU.dll /namespace:NMSDVDXLib /machine:X64 /out:obj\x64\Release\Interop.NMSDVDXLib.dll /sysarray /transform:DispRet /reference:c:\Assemblies\Bass.Net.dll /reference:c:\Assemblies\LogicNP.FileView.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\mscorlib.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.Data.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.Design.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.Drawing.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.Management.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.Windows.Forms.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.Xml.dll /reference:C:\WINDOWS\assembly\GAC\stdole\7.0.3300.0__b03f5f7f11d50a3a\stdole.dll ]]></message> <error code="TI0000" file="TlbImp"><![CDATA[A single valid machine type compatible with the input type library must be specified.]]></error> <warning code="MSB3283" file="C:\WINDOWS\Microsoft.NET\Framework\v4.0.30319\Microsoft.Common.targets" line="1558" column="9"><![CDATA[Die Wrapperassembly für die Typbibliothek "NMSDVDXLib" wurde nicht gefunden.]]></warning> <message level="high"><![CDATA[C:\Programme\Microsoft SDKs\Windows\v7.0A\bin\TlbImp.exe c:\Assemblies\StarBurnX12.dll /namespace:RocketDivision.StarBurnX /machine:X64 /out:obj\x64\Release\Interop.RocketDivision.StarBurnX.dll /sysarray /transform:DispRet /reference:c:\Assemblies\Bass.Net.dll /reference:c:\Assemblies\LogicNP.FileView.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\mscorlib.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.Data.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.Design.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.Drawing.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.Management.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.Windows.Forms.dll /reference:C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\System.Xml.dll /reference:C:\WINDOWS\assembly\GAC\stdole\7.0.3300.0__b03f5f7f11d50a3a\stdole.dll ]]></message> <error code="TI0000" file="TlbImp"><![CDATA[A single valid machine type compatible with the input type library must be specified.]]></error> <warning code="MSB3283" file="C:\WINDOWS\Microsoft.NET\Framework\v4.0.30319\Microsoft.Common.targets" line="1558" column="9"><![CDATA[Die Wrapperassembly für die Typbibliothek "RocketDivision.StarBurnX" wurde nicht gefunden.]]></warning> </target> Problem: A single valid machine type compatible with the input type library must be specified. It only applies to the x64 build of my project, x86 still works fine. Apparently, it tries to build a x64 interop assembly from the x86 DLL located in "C:\Assemblies". When executing the TlbImp command with the x64 DLL which is located in a different directory, it works fine. However, I don't know how I can configure my project to use different COM references for the x86 and x64 build. The OS on which the project is being compiled is WinXP x86. Building worked fine when using VS2005 + MSBuild 3.5 Any help would be highly appreciated. I tried building the upgraded project with MSBuild v3.5, but that doesn't work either. It complains about unknown NoWarn codes (probably new in 4.0).

    Read the article

  • Do you use an architectural framework for Flex/AIR development?

    - by Christophe Herreman
    Given that Flex is still a relatively young technology, there are already a bunch of architectural frameworks available for Flex/AIR (and Flash) development, the main ones being Cairngorm and PureMVC. The amount of architectural frameworks is remarkable compared to other technologies. I was wondering how many of you use an architectural framework for Flex development. If so, why, or why not if you don't use any? To share my own experience and point of view: I have used Cairngorm (and ARP for Flash development) on a variety of projects and found that at times, we needed to write extra code just to fit into the framework, which obviously didn't feel right. Although I haven't used PureMVC on many occasions, I have the same gut feeling after looking at the examples applications. Architectural frameworks equal religion in some way. Most followers are convinced that their framework is THE framework and are not open or very skeptical when it comes to using other frameworks. (I also find myself hesitant and skeptical to check out new frameworks, but that is mainly because I would rather wait until the hype is over.) In conclusion, I'm thinking that it is better to have a sound knowledge of patterns and practices that you can apply in your application instead of choosing a framework and sticking to it. There is simply no right or wrong and I don't believe that there will ever be a framework that is considered the holy grail.

    Read the article

  • "Could not establish secure channel for SSL/TLS" in .NET CF application on smart phone

    - by Stefan Mohr
    I have a stubborn communications issue with an application running on the .NET Compact Framework 3.5 on Windows Mobile smartphones. I am constructing a web request using this code: UTF8Encoding encoding = new System.Text.UTF8Encoding(); byte[] Data = encoding.GetBytes(HttpUtility.ConstructQueryString(parameters)); httpRequest = WebRequest.Create((domain)) as HttpWebRequest; httpRequest.Timeout = 10000000; httpRequest.ReadWriteTimeout = 10000000; httpRequest.Credentials = CredentialCache.DefaultCredentials; httpRequest.Method = "POST"; httpRequest.ContentType = "application/x-www-form-urlencoded"; httpRequest.ContentLength = Data.Length; Stream SendReq = httpRequest.GetRequestStream(); SendReq.Write(Data, 0, Data.Length); SendReq.Close(); HttpWebResponse httpResponse = (HttpWebResponse)httpRequest.GetResponse(); return httpResponse.GetResponseStream(); The web service functions by receiving a JSON-encoded document as part of the URL (eg. https://site.com/ws/sync??document={"version":"1.0.0","items":[{"item_1":"item1"}]}&user=usr&password=pw), and as a response receives another JSON document as response data. This code runs fine on all emulators and PDAs running WM 5 and 6. We have seen an issue with a couple of customers running Treo smartphones (and only on the Sprint network). We have tested the code on an identical device on the AT&T network (via DeviceAnywhere) and once again the code worked as we expected. This has to be some sort of security policy on the phone, but we've been unable to determine a workaround or diagnose it thoroughly as we cannot reproduce it in house and have had to resort to getting users to assist with running test drivers for us. When this code executes, the user's device throws the following exception: System.Net.WebException Could not establish secure channel for SSL/TLS Stack trace: at System.Net.HttpWebRequest.finishGetRequestStream() at System.Net.HttpWebRequest.GetRequestStream() at OurApp.GetResponseStream(String domain, Hashtable parameters) inner exception: System.IO.IOException Authentication failed because the remote party has closed the transport stream. Stack trace: at System.Net.SslConnectionState.ClientSideHandshake() at System.Net.SslConnectionState.PerformClientHandShake() at System.Net.Connection.connect(Object ignored) at System.Threading.ThreadPool.WorkItem.doWork(Object o) at System.Threading.Timer.ring() Examining the server Apache logs shows no hits from the user's IP - I don't think the device is even attempting to send a packet before failing. If relevant, the server is running Apache on Linux and is written using the TurboGears Python framework. The server certificate is issued by a CA and is still valid. The test driver where this error was copied from was not code signed, however the same error (without the error messages) is signed with a GeoTrust certificate so we don't believe this is a code signing issue. The application installs and launches without issue on all phones - it's just establishing this SSL connection that is breaking for these users. One significant issue in troubleshooting is that there is a substantial inconvenience each time we try out a solution (need to find a "volunteer" customer), so we're really looking for a silver bullet or a better understanding of the handshaking process so we can be reasonably confident we only need to ask the user to test it one or two more times. One final mention: we have tried the sync both over ActiveSync and also over GPRS with identical results. Any thoughts would be greatly appreciated!

    Read the article

  • Which PHP MVC Framework should I use with MongoDB?

    - by Justin Jenkins
    I have a number of smaller scale PHP projects lined up and would like to take advangtage of a framework. I've read these questions ... What PHP framework would you choose for a new application and why? Picking a PHP MVC Framework I found them useful but I need more specific opinions; here are my major requirements ... MongoDB support (the more 'built-in' the better, a full ORM is not needed however.) MVC (and nice pretty urls ... if you will ... too!) Must work on Apache (2.2) on Ubuntu (10.04.1 LTS), but nginx is also a nice plus. PHP 5.3 or greater. Nice to haves ... I'd prefer more readable code than lots of "shortcut" shorthand coding (that just ends up confusing me later.) I've used PHP for a number of years, but don't use a lot of it's OO (nor do I really care to.) I really love jQuery, so a framework that "thinks" the same way would be nice. Lightweight, I don't need a ton of features ... I just need to make my life easier. I've briefly looked at Lithium, CakePHP, Vork and Symfony ... What would be the best framework for my needs? EDIT: Also docs are pretty important, documentaction with examples! I can't stand to waste time figuring how to use a framework if it would have taken less time to code it myself.

    Read the article

  • Zend models and database relathionships

    - by user608341
    Hi people, i'm starting with Zend Framework and I'm a little bit confused with models and relathionships (one-to-many, many-to-many etc). The "Zend Framework Quick Start" says to create a Zend_Db_Table, a Data Mapper and finally our model class Suppose we have a database like this: table A ( id integer primary key, name varchar(50) ); table B ( id integer primary key, a_id integer references A ); then, i'll create: Application_Model_DbTable_A extends Zend_Db_Table_Abstract, Application_Model_AMapper, Application_Model_A, Application_Model_DbTable_B extends Zend_Db_Table_Abstract, Application_Model_BMapper, Application_Model_B, if I understood, i've to store the references informations in Application_Model_DbTable_A: protected $_dependentTables = array('B'); and Application_Model_DbTable_B: protected $_referenceMap = array( 'A' => array( 'columns' => array('a_id'), 'refTableClass' => 'A', 'refColums' => array('id') ) ); and my models class: class Application_Model_A { protected $_id; protected $_name; public function __construct(array $options = null) { if(is_array($options)) { $this->setOptions($options); } } public function __set($name, $value) { $method = 'set' . $name; if (('mapper' == $name) || !method_exists($this, $method)) { throw new Exception('Invalid property'); } $this->$method($value); } public function __get($name) { $method = 'get' . $name; if (('mapper' == $name) || !method_exists($this, $method)) { throw new Exception('Invalid property'); } return $this->$method(); } public function setOptions(array $options) { $methods = get_class_methods($this); foreach ($options as $key => $value) { $method = 'set' . ucfirst($key); if (in_array($method, $methods)) { $this->$method($value); } } return $this; } public function setName($name) { $this->_name = (string) $name; return $this; } public function getName() { return $this->_name; } public function setId($id) { $this->_id = (int) $id; return $this; } public function getId() { return $this->_id; } class Application_Model_B { protected $_id; protected $_a_id; public function __construct(array $options = null) { if(is_array($options)) { $this->setOptions($options); } } public function __set($name, $value) { $method = 'set' . $name; if (('mapper' == $name) || !method_exists($this, $method)) { throw new Exception('Invalid property'); } $this->$method($value); } public function __get($name) { $method = 'get' . $name; if (('mapper' == $name) || !method_exists($this, $method)) { throw new Exception('Invalid property'); } return $this->$method(); } public function setOptions(array $options) { $methods = get_class_methods($this); foreach ($options as $key => $value) { $method = 'set' . ucfirst($key); if (in_array($method, $methods)) { $this->$method($value); } } return $this; } public function setA_id($a_id) { $this->_a_id = (int) $a_id; return $this; } public function getA_id() { return $this->_a_id; } public function setId($id) { $this->_id = (int) $id; return $this; } public function getId() { return $this->_id; } it's that right?

    Read the article

  • Converting a Visual Studio 2003 Web Project to a Visual Studio 2008 Web Application Project

    - by navaneeth
    This walkthrough describes how to convert a Visual Studio .NET 2002 or Visual Studio .NET 2003 Web project to a Visual Studio 2008 Web application project. The Visual Studio 2008 Web application project model is like the Visual Studio 2005 Web application project model. Therefore, the conversion processes are similar. For more information about Web application projects, see ASP.NET Web Application Projects. You can also convert from a Visual Studio .NET Web project to a Visual Studio 2008 Web site project. However, conversion to a Web application project is the approach that is supported, and gives you the convenience of tools to help with the conversion. For example, when you convert to a Visual Studio 2008 Web application project, you can use the Visual Studio Conversion Wizard to automate part of the process. For information about how to convert a Visual Studio .NET Web project to a Visual Studio 2008 Web site, see Common Web Project Conversion Issues and Solutions. There are two parts involved in converting a Visual Studio 2002 or 2003 Web project to a Visual Studio 2008 Web application project. The parts are as follows: Converting the project. You can use the Visual Studio Conversion Wizard for the initial conversion of the project and Web.config files. You can later use the Convert To Web Application command to update the project's files and structure. Upgrading the .NET Framework version of the project. You must upgrade the project's .NET Framework version to either .NET Framework 2.0 SP1 or to .NET Framework 3.5. This .NET Framework version upgrade is required because Visual Studio 2008 cannot target earlier versions of the .NET Framework. You can perform this upgrade during the project conversion, by using the Conversion Wizard. Alternatively, you can upgrade the .NET Framework version after you convert the project.   NoteYou can change a project's .NET Framework version manually. To do so, in Visual Studio open the property pages for the project, click the Application tab, and then select a new version from the Target Framework list. This walkthrough illustrates the following tasks: Opening the Visual Studio .NET project in Visual Studio 2008 and creating a backup of the project files. Upgrading the .NET Framework version that the project targets. Converting the project file and the Web.config file. Converting ASP.NET code files. Testing the converted project. Prerequisites    To complete this walkthrough, you will need: Visual Studio 2008. A Web site project that was created in Visual Studio .NET version 2002 or 2003 that compiles and runs without errors. Converting the Project and Upgrading the .NET Framework Version    To begin, you open the project in Visual Studio 2008, which starts the conversion. It offers you an opportunity to back up the project before converting it. NoteIt is strongly recommended that you back up the project. The conversion works on the original project files, which cannot be recovered if the conversion is not successful.To convert the project and back up the files In Visual Studio 2008, in the File menu, click Open and then click Project. The Open Project dialog box is displayed. Browse to the folder that contains the project or solution file for the Visual Studio .NET project, select the file, and then click Open. NoteMake sure that you open the project by using the Open Project command. If you use the Open Web Site command, the project will be converted to the Web site project format.The Conversion Wizard opens and prompts you to create a backup before converting the project. To create the backup, click Yes. Click Browse, select the folder in which the backup should be created, and then click Next. Click Finish. The backup starts. NoteThere might be significant delays as the Conversion Wizard copies files, with no updates or progress indicated. Wait until the process finishes before you continue.When the conversion finishes, the wizard prompts you to upgrade the targeted version of the .NET Framework for the project. To upgrade to the .NET Framework 3.5, click Yes. To upgrade the project to target the .NET Framework 2.0 SP1, click No. It is recommended that you leave the check box selected that asks whether you want to upgrade all Webs in the solution. If you upgrade to .NET Framework 3.5, the project's Web.config file is modified at the same time as the project file. When the upgrade and conversion have finished, a message is displayed that indicates that you have completed the first step in converting your project. Click OK. The wizard displays status information about the conversion. Click Close. Testing the Converted Project    After the conversion has finished, you can test the project to make sure that it runs. This will also help you identify code in the project that must be updated. To verify that the project runs If you know about changes that are required for the code to run with the new version of the .NET Framework, make those changes. In the Build menu, click Build. Any missing references or other compilation issues in the project are displayed in the Error List window. The most likely issues are missing assembly references or issues with dynamically generated types. In Solution Explorer, right-click the Web page that will be used to launch the application, and then click Set as Start Page. On the Debug menu, click Start Debugging. If debugging is not enabled, the Debugging Not Enabled dialog box is displayed. Select the option to add a Web.config file that has debugging enabled, and then click OK. Verify that the converted project runs as expected. Do not continue with the conversion process until all build and run-time errors are resolved. Converting ASP.NET Code Files    ASP.NET Web page files and user-control files in Visual Studio 2008 that use the code-behind model have an associated designer file. The files that you just converted will have an associated code-behind file, but no designer file. Therefore, the next step is to generate designer files. NoteOnly ASP.NET Web pages and user controls that have their code in a separate code file require a separate designer file. For pages that have inline code and no associated code file, no designer file will be generated.To convert ASP.NET code files In Solution Explorer, right-click the project node, and then click Convert To Web Application. The files are converted. Verify that the converted code files have a code file and a designer file. Build and run the project to verify the results of the conversion.

    Read the article

  • How to install Huawei Mobile broadband EC306?

    - by serviteur
    How to install Huawei Mobile Broadband EC 306 EVDO RevB in Ubuntu 12.04 LTS 64bit ? Best Regards Excuses me for my bad english When I connect the modem on ubuntu, it fails to mount system and furthermore it is not recognized as a CD-ROM. I is not installed Windows on my computer, but I try to open the modem under Windows on a PC friend, There is no script file called "Linux", but only Windows. lsusb : serviteur@creation:~$ lsusb Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 002 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 003 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 004 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 005 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 006 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 007 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 008 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 007 Device 002: ID 15d9:0a4c Trust International B.V. USB+PS/2 Optical Mouse Bus 001 Device 007: ID 12d1:1506 Huawei Technologies Co., Ltd. E398 LTE/UMTS/GSM Modem/Networkcard dmesg Q: 0 ANSI: 2 [16619.060771] sr1: scsi-1 drive [16619.060955] sr 13:0:0:0: Attached scsi CD-ROM sr1 [16619.061099] sr 13:0:0:0: Attached scsi generic sg3 type 5 [16619.061358] sd 14:0:0:0: Attached scsi generic sg4 type 0 [16619.063654] sd 14:0:0:0: [sdc] Attached SCSI removable disk [16634.224923] usb 1-6: USB disconnect, device number 6 [16638.468041] usb 1-6: new high-speed USB device number 7 using ehci_hcd [16638.586210] option 1-6:1.0: GSM modem (1-port) converter detected [16638.586316] usb 1-6: GSM modem (1-port) converter now attached to ttyUSB0 [16638.586435] option 1-6:1.1: GSM modem (1-port) converter detected [16638.586517] usb 1-6: GSM modem (1-port) converter now attached to ttyUSB1 [16638.586607] option 1-6:1.2: GSM modem (1-port) converter detected [16638.586676] usb 1-6: GSM modem (1-port) converter now attached to ttyUSB2 [16638.586752] option 1-6:1.3: GSM modem (1-port) converter detected [16638.586828] usb 1-6: GSM modem (1-port) converter now attached to ttyUSB3 [16638.586929] option 1-6:1.4: GSM modem (1-port) converter detected [16638.586997] usb 1-6: GSM modem (1-port) converter now attached to ttyUSB4 [16638.587114] option 1-6:1.5: GSM modem (1-port) converter detected [16638.587187] usb 1-6: GSM modem (1-port) converter now attached to ttyUSB5 [16638.646686] option1 ttyUSB5: GSM modem (1-port) converter now disconnected from ttyUSB5 [16638.646706] option 1-6:1.5: device disconnected [16638.660755] scsi15 : usb-storage 1-6:1.5 [16638.663284] option1 ttyUSB4: GSM modem (1-port) converter now disconnected from ttyUSB4 [16638.663301] option 1-6:1.4: device disconnected [16638.689043] scsi16 : usb-storage 1-6:1.4

    Read the article

  • VS 2010 ALM Whitepapers &ndash; link from Neno Loje

    - by johndoucette
    Overview of Visual Studio ALM Whitepapers by Microsoft Overview Visual Studio 2010 Quick Reference Guidance Installation, Configuration & Administration Team Foundation Installation Guide for Visual Studio Team System 2010 Administration Guide for Microsoft Visual Studio 2010 Team Foundation Server Visual Studio 2010 TFS Upgrade Guide Visual Studio 2010 and Team Foundation Server 2010 VM Factory TFS Integration Platform Visual Studio 2010 Licensing White Paper Requirements Visual Studio 2010 Team Foundation Server Requirements Management Guidance Version Control & Configuration Management Visual Studio TFS Branching Guide 2010 Some guide or whitepaper missing? Let me know!

    Read the article

  • E160 ubuntu 12.04 can't detect the modem

    - by Matt
    i've got problem with e160 on ubuntu 12.04. I'cant configure network manager and connect because NM can't see the e160. I;ve tried lot of solutions with no result. ateusz@mateusz-Aspire-5738:~$ sudo usb_modeswitch -v 0x12d1 -p 0x1003 -H [sudo] password for mateusz: aLooking for default devices ... found matching product ID adding device Found device in default mode, class or configuration (1) Accessing device 002 on bus 001 ... Getting the current device configuration ... OK, got current device configuration (1) Using first interface: 0x00 Using endpoints 0x01 (out) and 0x82 (in) Not a storage device, skipping SCSI inquiry USB description data (for identification) ------------------------- Manufacturer: HUAWEI Technology Product: HUAWEI Mobile Serial No.: not provided ------------------------- Sending Huawei control message ... OK, Huawei control message sent - Run lsusb to note any changes. Bye. Dmesg [ 521.480062] usb 1-4: reset high-speed USB device number 4 using ehci_hcd [ 521.617792] option 1-4:1.1: GSM modem (1-port) converter detected [ 521.617945] usb 1-4: GSM modem (1-port) converter now attached to ttyUSB0 [ 521.618062] option 1-4:1.0: GSM modem (1-port) converter detected [ 521.618232] usb 1-4: GSM modem (1-port) converter now attached to ttyUSB1 [ 530.840276] option: option_instat_callback: error -108 [ 530.840455] option1 ttyUSB1: GSM modem (1-port) converter now disconnected from ttyUSB1 [ 530.840484] option 1-4:1.0: device disconnected [ 537.680378] option1 ttyUSB0: GSM modem (1-port) converter now disconnected from ttyUSB0 [ 537.680398] option 1-4:1.1: device disconnected [ 537.792088] usb 1-4: reset high-speed USB device number 4 using ehci_hcd [ 537.929549] option 1-4:1.1: GSM modem (1-port) converter detected [ 537.929702] usb 1-4: GSM modem (1-port) converter now attached to ttyUSB0 [ 537.929818] option 1-4:1.0: GSM modem (1-port) converter detected [ 537.929993] usb 1-4: GSM modem (1-port) converter now attached to ttyUSB1 [ 547.224294] option: option_instat_callback: error -108 [ 547.224470] option1 ttyUSB1: GSM modem (1-port) converter now disconnected from ttyUSB1 [ 547.224511] option 1-4:1.0: device disconnected [ 556.988066] tty_ldisc_hangup: waiting (usb-storage) for ttyUSB0 took too long, but we keep waiting... [ 558.990663] option1 ttyUSB0: GSM modem (1-port) converter now disconnected from ttyUSB0 [ 558.990698] option 1-4:1.1: device disconnected [ 559.100068] usb 1-4: reset high-speed USB device number 4 using ehci_hcd [ 559.241293] option 1-4:1.1: GSM modem (1-port) converter detected [ 559.241446] usb 1-4: GSM modem (1-port) converter now attached to ttyUSB0 [ 559.241565] option 1-4:1.0: GSM modem (1-port) converter detected [ 559.241739] usb 1-4: GSM modem (1-port) converter now attached to ttyUSB1 [ 568.728283] option: option_instat_callback: error -108 [ 568.728466] option1 ttyUSB1: GSM modem (1-port) converter now disconnected from ttyUSB1 [ 568.728496] option 1-4:1.0: device disconnected lsusb Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 002 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 003 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 004 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 005 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 006 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 007 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 008 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 002 Device 003: ID 064e:a103 Suyin Corp. Acer/HP Integrated Webcam [CN0314] Bus 005 Device 002: ID 09da:c20a A4 Tech Co., Ltd Bus 001 Device 002: ID 12d1:1003 Huawei Technologies Co., Ltd. E220 HSDPA Modem / E230/E270/E870 HSDPA/HSUPA Modem

    Read the article

  • Just re-installed Ubuntu 14.04, unstable wireless connection, Lenovo ThinkPad X200

    - by Mark Lawtie
    I re-installed Ubuntu 14.04 as I was having problems with unstable wireless connection... Following re-installation I am having the same problem: connection randomly dropping out, then reconnecting... all my other devices are running well when connected I am a bit of a computer novice so any help would be greatly appreciated... I am running Lenovo ThinkPad X200 laptop... Thanks! mark@mark-ThinkPad-X200:~$ lspci 00:00.0 Host bridge: Intel Corporation Mobile 4 Series Chipset Memory Controller Hub (rev 07) 00:02.0 VGA compatible controller: Intel Corporation Mobile 4 Series Chipset Integrated Graphics Controller (rev 07) 00:02.1 Display controller: Intel Corporation Mobile 4 Series Chipset Integrated Graphics Controller (rev 07) 00:03.0 Communication controller: Intel Corporation Mobile 4 Series Chipset MEI Controller (rev 07) 00:19.0 Ethernet controller: Intel Corporation 82567LM Gigabit Network Connection (rev 03) 00:1a.0 USB controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #4 (rev 03) 00:1a.1 USB controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #5 (rev 03) 00:1a.2 USB controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #6 (rev 03) 00:1a.7 USB controller: Intel Corporation 82801I (ICH9 Family) USB2 EHCI Controller #2 (rev 03) 00:1b.0 Audio device: Intel Corporation 82801I (ICH9 Family) HD Audio Controller (rev 03) 00:1c.0 PCI bridge: Intel Corporation 82801I (ICH9 Family) PCI Express Port 1 (rev 03) 00:1c.1 PCI bridge: Intel Corporation 82801I (ICH9 Family) PCI Express Port 2 (rev 03) 00:1c.3 PCI bridge: Intel Corporation 82801I (ICH9 Family) PCI Express Port 4 (rev 03) 00:1d.0 USB controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #1 (rev 03) 00:1d.1 USB controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #2 (rev 03) 00:1d.2 USB controller: Intel Corporation 82801I (ICH9 Family) USB UHCI Controller #3 (rev 03) 00:1d.7 USB controller: Intel Corporation 82801I (ICH9 Family) USB2 EHCI Controller #1 (rev 03) 00:1e.0 PCI bridge: Intel Corporation 82801 Mobile PCI Bridge (rev 93) 00:1f.0 ISA bridge: Intel Corporation ICH9M-E LPC Interface Controller (rev 03) 00:1f.2 SATA controller: Intel Corporation 82801IBM/IEM (ICH9M/ICH9M-E) 4 port SATA Controller [AHCI mode] (rev 03) 00:1f.3 SMBus: Intel Corporation 82801I (ICH9 Family) SMBus Controller (rev 03) 03:00.0 Network controller: Intel Corporation PRO/Wireless 5100 AGN [Shiloh] Network Connection mark@mark-ThinkPad-X200:~$ mark@mark-ThinkPad-X200:~$ lsusb Bus 002 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 008 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 007 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 006 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 005 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 004 Device 026: ID 0a5c:2145 Broadcom Corp. BCM2045B (BDC-2.1) [Bluetooth Controller] Bus 004 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 003 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub mark@mark-ThinkPad-X200:~$

    Read the article

  • Free Document/Content Management System Using SharePoint 2010

    - by KunaalKapoor
    That’s right, it’s true. You can use the free version of SharePoint 2010 to meet your document and content management needs and even run your public facing website or an internal knowledge bank.  SharePoint Foundation 2010 is free. It may not have all the features that you get in the enterprise license but it still has enough to cater to your needs to build a document management system and replace age old file shares or folders. I’ve built a dozen content management sites for internal and public use exploiting SharePoint. There are hundreds of web content management systems out there (see CMS Matrix).  On one hand we have commercial platforms like SharePoint, SiteCore, and Ektron etc. which are the most frequently used and on the other hand there are free options like WordPress, Drupal, Joomla, and Plone etc. which are pretty common popular as well. But I would be very surprised if anyone was able to find a single CMS platform that is all things to all people. Infact not a lot of people consider SharePoint’s free version under the free CMS side but its high time organizations benefit from this. Through this blog post I wanted to present SharePoint Foundation as an option for running a FREE CMS platform. Even if you knew that there is a free version of SharePoint, what most people don’t realize is that SharePoint Foundation is a great option for running web sites of all kinds – not just team sites. It is a great option for many reasons, but in reality it is supported by Microsoft, and above all it is FREE (yay!), and it is extremely easy to get started.  From a functionality perspective – it’s hard to beat SharePoint. Even the free version, SharePoint Foundation, offers simple data connectivity (through BCS), cross browser support, accessibility, support for Office Web Apps, blogs, wikis, templates, document support, health analyzer, support for presence, and MUCH more.I often get asked: “Can I use SharePoint 2010 as a document management system?” The answer really depends on ·          What are your specific requirements? ·          What systems you currently have in place for managing documents. ·          And of course how much money you have J Benefits? Not many large organizations have benefited from SharePoint yet. For some it has been an IT project to see what they can achieve with it, for others it has been used as a collaborative platform or in many cases an extended intranet. SharePoint 2010 has changed the game slightly as the improvements that Microsoft have made have been noted by organizations, and we are seeing a lot of companies starting to build specific business applications using SharePoint as the basis, and nearly every business process will require documents at some stage. If you require a document management system and have SharePoint in place then it can be a relatively straight forward decision to use SharePoint, as long as you have reviewed the considerations just discussed. The collaborative nature of SharePoint 2010 is also a massive advantage, as specific departmental or project sites can be created quickly and easily that allow workers to interact in a variety of different ways using one source of information.  This also benefits an organization with regards to how they manage the knowledge that they have, as if all of their information is in one source then it is naturally easier to search and manage. Is SharePoint right for your organization? As just discussed, this can only be determined after defining your requirements and also planning a longer term strategy for how you will manage your documents and information. A key factor to look at is how the users would interact with the system and how much value would it get for your organization. The amount of data and documents that organizations are creating is increasing rapidly each year. Therefore the ability to archive this information, whilst keeping the ability to know what you have and where it is, is vital to any organizations management of their information life cycle. SharePoint is best used for the initial life of business documents where they need to be referenced and accessed after time. It is often beneficial to archive these to overcome for storage and performance issues. FREE CMS – SharePoint, Really? In order to show some of the completely of what comes with this free version of SharePoint 2010, I thought it would make sense to use Wikipedia (since every one trusts it as a credible source). Wikipedia shows that a web content management system typically has the following components: Document Management:   -       CMS software may provide a means of managing the life cycle of a document from initial creation time, through revisions, publication, archive, and document destruction. SharePoint is king when it comes to document management.  Version history, exclusive check-out, security, publication, workflow, and so much more.  Content Virtualization:   -       CMS software may provide a means of allowing each user to work within a virtual copy of the entire Web site, document set, and/or code base. This enables changes to multiple interdependent resources to be viewed and/or executed in-context prior to submission. Through the use of versioning, each content manager can preview, publish, and roll-back content of pages, wiki entries, blog posts, documents, or any other type of content stored in SharePoint.  The idea of each user having an entire copy of the website virtualized is a bit odd to me – not sure why anyone would need that for anything but the simplest of websites. Automated Templates:   -       Create standard output templates that can be automatically applied to new and existing content, allowing the appearance of all content to be changed from one central place. Through the use of Master Pages and Themes, SharePoint provides the ability to change the entire look and feel of site.  Of course, the older brother version of SharePoint – SharePoint Server 2010 – also introduces the concept of Page Layouts which allows page template level customization and even switching the layout of an individual page using different page templates.  I think many organizations really think they want this but rarely end up using this bit of functionality.  Easy Edits:   -       Once content is separated from the visual presentation of a site, it usually becomes much easier and quicker to edit and manipulate. Most WCMS software includes WYSIWYG editing tools allowing non-technical individuals to create and edit content. This is probably easier described with a screen cap of a vanilla SharePoint Foundation page in edit mode.  Notice the page editing toolbar, the multiple layout options…  It’s actually easier to use than Microsoft Word. Workflow management: -       Workflow is the process of creating cycles of sequential and parallel tasks that must be accomplished in the CMS. For example, a content creator can submit a story, but it is not published until the copy editor cleans it up and the editor-in-chief approves it. Workflow, it’s in there. In fact, the same workflow engine is running under SharePoint Foundation that is running under the other versions of SharePoint.  The primary difference is that with SharePoint Foundation – you need to configure the workflows yourself.   Web Standards: -       Active WCMS software usually receives regular updates that include new feature sets and keep the system up to current web standards. SharePoint is in the fourth major iteration under Microsoft with the 2010 release.  In addition to the innovation that Microsoft continuously adds, you have the entire global ecosystem available. Scalable Expansion:   -       Available in most modern WCMSs is the ability to expand a single implementation (one installation on one server) across multiple domains. SharePoint Foundation can run multiple sites using multiple URLs on a single server install.  Even more powerful, SharePoint Foundation is scalable and can be part of a multi-server farm to ensure that it will handle any amount of traffic that can be thrown at it. Delegation & Security:  -       Some CMS software allows for various user groups to have limited privileges over specific content on the website, spreading out the responsibility of content management. SharePoint Foundation provides very granular security capabilities. Read @ http://msdn.microsoft.com/en-us/library/ee537811.aspx Content Syndication:  -       CMS software often assists in content distribution by generating RSS and Atom data feeds to other systems. They may also e-mail users when updates are available as part of the workflow process. SharePoint Foundation nails it.  With RSS syndication and email alerts available out of the box, content syndication is already in the platform. Multilingual Support: -       Ability to display content in multiple languages. SharePoint Foundation 2010 supports more than 40 languages. Read More Read more @ http://msdn.microsoft.com/en-us/library/dd776256(v=office.12).aspxYou can download the free version from http://www.microsoft.com/en-us/download/details.aspx?id=5970

    Read the article

  • Alfa AWUS036H USB wireless adapter not recognized

    - by GFiasco
    The Alfa AWUS036H USB wireless adapter will not be recognized by my netbook (Ubuntu 14.04, Asus X201E). As I understand it, the drivers should already be built in to this version of Linux, but I tried a make/make install of the latest Realtek drivers (as mentioned on How do I install drivers for the Alfa AWUS036H USB wireless adapter?) and it didn't work. I then followed the advice of this thread (ALFA AWUS036NH driver) and did a make/make install of the most up-to-date backport of the drivers, but that didn't work. At this point I tried a series of commands from this thread (http://ubuntuforums.org/showthread.php?t=2187780) in an attempt to identify the problem, but at no point could I get the laptop to ever recognize the USB adapter. I have also troubleshot the USB cable itself, tried both the USB 2.0 and 3.0 ports on the laptop, have never received an error message regarding a need to update the firmware, and have seemingly successfully installed all manner of variation of Realtek drivers which were supposed to make the adapter work. (I also tried to delete/clean up after each install, in the hope I wasn't making things worse.) Not sure what I should do next. Please let me know if I need to post any more information. Thanks very much for your help. EDIT: Before inserting Alpha USB adapter: :~$ lsusb Bus 002 Device 002: ID 8087:0024 Intel Corp. Integrated Rate Matching Hub Bus 002 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 001 Device 004: ID 0bda:570c Realtek Semiconductor Corp. Bus 001 Device 026: ID 13d3:3393 IMC Networks Bus 001 Device 002: ID 8087:0024 Intel Corp. Integrated Rate Matching Hub Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 004 Device 001: ID 1d6b:0003 Linux Foundation 3.0 root hub Bus 003 Device 002: ID 03f0:3112 Hewlett-Packard Bus 003 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub After inserting Alpha USB adapter (USB 3.0 port, no change): :~$ lsusb Bus 002 Device 002: ID 8087:0024 Intel Corp. Integrated Rate Matching Hub Bus 002 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 001 Device 004: ID 0bda:570c Realtek Semiconductor Corp. Bus 001 Device 026: ID 13d3:3393 IMC Networks Bus 001 Device 002: ID 8087:0024 Intel Corp. Integrated Rate Matching Hub Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Bus 004 Device 001: ID 1d6b:0003 Linux Foundation 3.0 root hub Bus 003 Device 002: ID 03f0:3112 Hewlett-Packard Bus 003 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub Ran tail -f /var/log/syslog, inserted device, no recognition (last entry is dated 16:17:01, so an hour ago). Going to check on an Ubuntu 14.04 laptop and Windows XP desktop. I'll update after. Thanks for your help to this point.

    Read the article

  • How to update correctly an Entity Model after changes of database structure?

    - by Slauma
    I've made some changes in the table structure and especially the relationships between tables in my SQL Server database. Now I want to update my Entity model based on this new database structure. Right clicking on the edmx file I find the option "Update model from database". But when I do this I get kind of a 50% update: The new columns appear in the Entity classes but I am confused about a lot of navigation properties which are still there in the model although the corresponding foreign key relationships do not exist anymore in the database. Am I doing something wrong? Or is there another option to update the model including deletion of navigation properties? Or do I have to delete those navigation properties manually in the model files? I am using Entity Framework Version 1 (VS 2008 SP1). Thanks for help in advance!

    Read the article

  • AuthSub target path prefix does not match the provided "next" URL

    - by dweebsonduty
    I am trying to use the Gcal API in PHP. I am using the ZEND framework function getAuthSubUrl($company) { $next = "http://$company.mysite.com"; $scope = 'http://www.google.com/calendar/feeds/'; $secure = false; $session = true; return (Zend_Gdata_AuthSub::getAuthSubTokenUri($next, $scope, $secure, $session)); } $authSubUrl = getAuthSubUrl(); echo "<a href=\"$authSubUrl\">login to your Google account"</a> I am not sure what I am doing wrong here. I am following the google example almost exactly. They do have $next = getCurrentUrl(); in their expample but I am getting undefined errors when I try that.

    Read the article

  • LinkDemand error on webserver when using TraceSource

    - by robertpnl
    Hi, On a webserver (shared hosting provider) I published a website with a ADO.Net Framework model in use with MySql Connector 6.3.1. When I request a page, a Security Exception will be happen with this error messages: "LinkDemand The type of the first permission that failed was: System.Security.Permissions.SecurityPermission The Zone of the assembly that failed was: MyComputer ". This exception raised when code collect the listeners of a tracksource: public class MySqlTrace { private static TraceSource source = new TraceSource("mysql"); static MySqlTrace() { foreach (TraceListener listener in source.Listeners) // <-- Exception throw here { // ... } } } The web.config doesn't have any trace data or system.diagnostics. My question is, why will a get a LinkDemand security exception during collecting the source listeners. What can maybe be wrong in here?

    Read the article

  • Using LIKE operator in LINQ to Entity

    - by Draconic
    Hi, everybody! Currently in our project we are using Entity Framework and LINQ. We want to create a search feature where the Client fills different filters but he isn't forced to. To do this "dynamic" query in LINQ, we thought about using the Like operator, searching either for the field, or "%" to get everything if the user didn't fill that field. The joke's on us when we discovered it didn't support Like. After some searching, we read several answers where it's sugested to use StartsWith, but it's useless for us. Is the only solution using something like: ObjectQuery<Contact> contacts = db.Contacts; if (pattern != "") { contacts = contacts.Where(“it.Name LIKE @pattern”); contacts.Parameters.Add(new ObjectParameter(“pattern”, pattern); } However, we'd like to stick with linq only. Happy coding!

    Read the article

  • Zend - combobox value depending on another combobox value

    - by Sorin Adrian Carbunaru
    Is there a way in Zend Framework to fill a combobox with values depending on the value chosen in a previous combobox, but on the same page? In my case I have a combobox for domain and one for specialization. If i choose Informatics in the first combobox (domain), I want to fill the second one with a single specialization - "Informatics". But if I choose Math in the first, I want to fill the second one with two specialization: "Mathematics" and "Mathematics & Informatics". Thank you! Sorin

    Read the article

  • Display empty textbox using Html.TextBoxFor on a not-null property in an EF entity.

    - by hungster
    I am using Entity Framework (v4) entities. I have an entity called Car with a Year property of type integer. The Year property does not allow NULL. I have the following in my Create view: <%= Html.TextBoxFor(model => model.Year) %> I am required to return a new Car object (due to other requirements) in my HttpGet Create action in the CarController. Currently, a zero is displayed in the Year textbox because the Year property does not allow NULL. I would like to display an empty textbox in the Create view. How do I do this?

    Read the article

< Previous Page | 139 140 141 142 143 144 145 146 147 148 149 150  | Next Page >