Search Results

Search found 28747 results on 1150 pages for 'switch case'.

Page 145/1150 | < Previous Page | 141 142 143 144 145 146 147 148 149 150 151 152  | Next Page >

  • Is there a Windows 7 equivalent to the *NIX ability to create a hard link to /dev/null?

    - by minameismud
    I saw another question here that the Windows equivalent to /dev/null is simply NUL. I also know that you can use the mklink command to make sym links (shortcuts) from the command line: MKLINK [[/D] | [/H] | [/J]] Link Target /D Creates a directory symbolic link. Default is a file symbolic link. /H Creates a hard link instead of a symbolic link. /J Creates a Directory Junction. Link specifies the new symbolic link name. Target specifies the path (relative or absolute) that the new link refers to. When I try to use the /j switch to make a hard link ("junction") instead of a simple shortcut to NUL, I get: C:\>mklink /j "C:\Program Files\MyNewHardlinkFolder" NUL Local volumes are required to complete the operation. I can create shortcuts to NUL all day long using the /d switch, but I would much prefer the hard link. Any ideas?

    Read the article

  • Link bonding across multiple switches?

    - by Bryan Agee
    I've read up a little bit on bonding nics with ifenslave; what I'm having trouble understanding is whether there is special configuration needed in order to split the bonds across two switches. For example, if I have several servers that all have two nics each, and two separate switches, do I just configure the bonds and plug 1 nic from each into switch #1 and the other from each into switch #2? or is there more to it than that? If the bonds are active-backup, will a nic failure on single machine mean that server may become disconnected since the rest of the machines are using the primary nic and it's using the secondary? Or do you link the switches with one cable as well?

    Read the article

  • How to get access to console to reset Cisco 3750?

    - by genehack
    I acquired two Cisco 3750 switches from another part of my organization. I was able to complete the standard password/config reset procedure on one without any issues -- boot it, put it into express config mode, telnet in, reset the passwords, etc. The second one doesn't ever boot to the point where it displays anything on the console. When power cycled, the 'SYST' light flashes green a few times, then comes on a solid green and stays lit. None of the other lights ever flash or light up. Holding down the 'MODE' button for up to 30 seconds produces no noticeable effects. Nothing ever comes out on the console. Since I was able to configure the first one without any problems, I know my connectinon is good -- console port configured right, good cable, etc. Is this just a hardware problem with the switch? Is there any way I can recover from this and get the switch back into a state where I can configure it?

    Read the article

  • Why do partially failed/failing switches fail to pass DHCP?

    - by David Mackintosh
    I've noticed this several times: a switch starts to behave oddly. Usually if the switch doesn't fail outright, what tends to get noticed is that DHCP doesn't work. We had a Linksys SRW-224P fail today. Systems which were still connected worked properly, until it came time to renew their DHCP lease. Once the lease expired, they stopped working, but up until then we couldn't detect a failure. This includes PoE VoIP phones -- they work fine until their lease is up, at which point they're done. I've noticed this on the above-mentioned Linksys, three varieties of 3Com, and possibly half a dozen dumb switches. What is it about DHCP that makes it sensitive to failing switches?

    Read the article

  • Allowing non-admin users to unstick the print spooler

    - by Reafidy
    I currently have an issue where the print que is getting stuck on a central print server (windows server 2008). Using the "Clear all documents" function does not clear it and gets stuck too. I need non-admin users to be able to clear the print cue from there work stations. I have tried using the following winforms program which I created and allows a user to stop the print spooler, delete printer files in the "C:\Windows\System32\spool\PRINTERS folder" and then start the print spooler but this functionality requires the program to be runs as an administrator, how can I allow my normal users to execute this program without giving them admin privileges? Or is there another way I can allow normal user to clear the print que on the server? Imports System.ServiceProcess Public Class Form1 Private Sub Button1_Click(sender As System.Object, e As System.EventArgs) Handles Button1.Click ClearJammedPrinter() End Sub Public Sub ClearJammedPrinter() Dim tspTimeOut As TimeSpan = New TimeSpan(0, 0, 5) Dim controllerStatus As ServiceControllerStatus = ServiceController1.Status Try If ServiceController1.Status <> ServiceProcess.ServiceControllerStatus.Stopped Then ServiceController1.Stop() End If Try ServiceController1.WaitForStatus(ServiceProcess.ServiceControllerStatus.Stopped, tspTimeOut) Catch Throw New Exception("The controller could not be stopped") End Try Dim strSpoolerFolder As String = "C:\Windows\System32\spool\PRINTERS" Dim s As String For Each s In System.IO.Directory.GetFiles(strSpoolerFolder) System.IO.File.Delete(s) Next s Catch ex As Exception MsgBox(ex.Message) Finally Try Select Case controllerStatus Case ServiceControllerStatus.Running If ServiceController1.Status <> ServiceControllerStatus.Running Then ServiceController1.Start() Case ServiceControllerStatus.Stopped If ServiceController1.Status <> ServiceControllerStatus.Stopped Then ServiceController1.Stop() End Select ServiceController1.WaitForStatus(controllerStatus, tspTimeOut) Catch MsgBox(String.Format("{0}{1}", "The print spooler service could not be returned to its original setting and is currently: ", ServiceController1.Status)) End Try End Try End Sub End Class

    Read the article

  • What is the main reason of adsl modem/routers dying ?

    - by ldigas
    The other day my home adsl modem/router (dwg 684t in this case) died. A guy from the telecom company came, brought another so no problem in day to day operation, but he also left this one. Now, I'm interested ... it didn't fall, it wasn't electrocuted ... but it just doesn't work. What could be the problem ? Can they be fixed ? Is it worth it (in which case I would have two which is always nice) ... What are the usual problems that occur with them ? In this case, I can connect to the router, I can see its settings, I just can't connect to the internet. With the new one everything works. Weird. Edit: Additional question: Can those things be fixed ? I mean, is it worth giving it to a local tinker for him to experiment on it ? I'm not looking for a definite opinion, just your personal advice ... (although in the end I think I'm gonna archive it in the "cylinder register")

    Read the article

  • git : The remote end hung up unexpectedly - too many simultaneous users?

    - by Pritam Barhate
    I asked this first on StackOverflow and I was suggested that I should ask it here: We have a self hosted git server (Gitolite) on a VPS account (CPU:2.68GHz RAM:1824MB). This same VPS is also used to publish our underdevelopment web apps for client demos. (Very little traffic). so the main use of the server is as a Git Server Only. This git server is accessed by a team of 30-40 people for various projects. Our problem is that during the day when 6-7 people are trying to access the server (sometimes same repo) we get frequent error message: ssh: connect to host xxx.xxx.xx.xx port 22: Bad file number fatal: The remote end hung up unexpectedly After trying for 10-15 minutes it generally succeeds. During early mornings and late nights when there are only 1-2 people, git commands work with 100% success rate. Also I would like to note that if I access the other file hosted on the server through HTTP it works fine. I found a couple of questions on StackOverflow and on other sites regarding this. But most of the people point towards SSH key set up or conflicts between Msysgit and Cygns SSH. However I don't think this is the problem in our case as we get this behavior on Windows (using msysgit only) as well as Mac Machines. Also if it was SSH configuration issue then it shouldn't work at all. But in our case it works after 10-15 minutes. I think in our case it might be too many simultaneous connections to same server (or same repo) or something like that. Does there exists a setting or a conf file that needs to modified to solve this problem? Please help me solve this problem or point me in the right direction. Thanks in advance. Pritam.

    Read the article

  • Using curly braces with a standard pc keyboard on a mac laptop

    - by raoulsson
    I have a standard PC keyboard connection to my Mac laptop. All keys work fine but the special characters that need "Alt-Gr" as accelerator keys would not work. I have a Swiss layout where the curly braces are such special keys. However I need them all the time and having to get used to a different layout is too painful (I'd rather get used to a US Layout once and for all). Does anyone have an idea how to switch this? Note: I have managed to switch the option and the command key, so that's not my problem.

    Read the article

  • failure daemon and changing pid number

    - by Alessandra Bilardi
    proftpd, sshd and apache processes run with /etc/init.d/its-script on linux distro. I was monitoring 21, 22 and 80 ports with farm monitoring service: every 5 minutes service check each port and notify only failure. The failures were 5-6 times on 24h. It seems that someone kicks the switch sometimes.. I add monit and collectd monitoring and the monitoring about 21, 22 and 80 ports is every 1 minute. I do not receive farm monitoring service notify. I receive only monit notify about failure and/or succeed/changing pid number of proftpd, sshd or apache process. The failures are still 5-6 times on 24h. collectd monitoing about cpu, load average and each process is regular and there are no peaks. There is nothing kicks the switch but there is something which determines failure monitoring. is it a simple interference or is it indicative of some abnormality? What could cause these failures?

    Read the article

  • Switching to some emacs shell buffers moves the cursor to the beginning of the buffer

    - by yuvilio
    I run Emacs 24 with prelude and a few shells that i invoke at the start ( e.g.: (shell "*shell*_spare") ). When i switch to some of them (C-x b), my cursor lands at the beginning of the buffer, rather than when it last left off (typically the end of the buffer after the last command I ran). The strange thing is that this does not happen for all the shell buffers that I set up in the same way but with different names. When I switch to them, the cursor is where it last left off. Any ideas how I can make the cursor always be where it last was or at the bottom?

    Read the article

  • Program (or perhaps built-in feature of Windows 7) to change wallpaper depending on screen resolution?

    - by Lasse V. Karlsen
    I have a laptop with a resolution of 1680x1050. At work I use 2x 1280x1024 monitors, and sometimes I present using a projector that is 1024x768. My wallpaper, that I made for 1680x1050, looks awful on the other resolutions. Is there anything I can do that would make Windows 7 switch to a different wallpaper that has been cropped appropriately? ie. can I give Windows more than one wallpaper, with different resolutions, and have Windows 7 switch automatically to a matching one? If there is a free (or relatively cheap) piece of software I could download and install that would fix it, that would be OK too.

    Read the article

  • Speakers will not work after I use USB Headset

    - by Josh K
    I am trying to configure my SteelSeries Siberia V2 Frost USB Headset to work with my 2.0 speakers using a jack. My goal is to find a easy way (no restart) to switch playback from my headset and my speakers and vice-versa. If i plug my headset in and make it the default device then restart my application/web page then the sounds works out of headset. If I switch the default to my speakers and restart apps/web pages then sound does not play. I know my speakers are on because if I configure them through windows and test, the sounds play, and sounds also play when I test it through my audio manager. Even if I unplug my headset, I still cannot get sound out of my speakers unless I restart My audio manager is RealTek HD Audio Manager, Windows 7 x64. I have tried the speaker back, usb front. speaker front, usb in front port. I have not tried speaker back, usb back.

    Read the article

  • 10 System LAN latency with ADSL modem as gateway

    - by itsoft3g
    Recently I expanded LAN in my office from 3 to 10 computers. Structure star topology, one ADSL Modem connected to One Switch which is again connected to 10 computers. Also we have Wifi device Netgear which is connected from switch. ADSL Modem acts as the DHCP Server, all the system will have default gateway IP (ADSL Modem's IP) Network latency is now become very high, All the chat severs disconnect often like google talk, skype etc, also internet become very very slow. when all the computer turned on. We have 4 Mbps Download and 100 Kbps upload Net speed. Its look like ADSL Modem cannot able to handle all the connections. I tried to setup a system as default gateway which will connect to modem, not sure how to do this. Please advice on this.

    Read the article

  • Finding spoofed IP address on network

    - by Jared
    I have a few IP spoof dropped messages coming out of my Sonicwall firewall, we'll call them Source A and Source B. Both of these sources have the same mac address indicating they're coming from the layer 3 switch behind my firewall. Source A has an ip within a valid subnet on my network and it shows up in the ARP table of my layer 3 switch. I was able to trace the exact location and fix the issue. Source B's ip however, is not within valid subnet on my network and it's not showing up in my layer 3 switches arp table. Any idea how I can trace the location of this device within my network? Thanks in advance.

    Read the article

  • How to check if a server runs in pressing mode

    - by Ice
    Hi there, Layout: i have at customer side a server (win2003 R2 SP2 standard edition 32-bit) with a sql-server 2005 and some databases. This system starts with the /3GB-Switch. The system reports 3.25 GB RAM and taskmanager reports the process of sqlserver.exe with 2758255 K as the process with the highest consumption. The OS separates RAM for applications and for itself, normaly 50:50. But here we have the /3GB-Switch aktivated and i think the part for the applications is more than 50% of RAM. Knowledge (or better not knowledge): Somebody told me that if the OS runs out of memory within his part of RAM, the server runs into pressing mode. Questions: What is this pressing mode? Is pressing mode possible at all in this szenario? What should be done to get more performance out of this sql-server, beside optimizing the database and all this stuff.

    Read the article

  • Virtualbox fullscreen mode problem

    - by AtharvaI
    hi all I have a slightly weird issue with virtualbox. My host OS is Win7 (64-bit) and guest OS is Ubuntu 10.10(64-bit). When I switch to fullscreen mode in virtualbox, ubuntu display resizes to fit my screen size. however, after that the display is not updated. So if i click a menu or something I don't see it appear. but it seems to work in the background. if i click a menu in fullscreen mode, i don't see anything happen, but if then switch to windowed mode I see the menu already open. I have installed virtuabox guest additions. if any has a similar issue or has found a solution please let me know thanks.

    Read the article

  • How should I troubleshoot a problematic wireless connection on Linux?

    - by Gearoid Murphy
    I recently purchased a netgear 150 usb wireless dongle for use with my 11.10 Xubuntu amd64 system. Using the network-manager interface, I can see local wireless networks and enter the authentication details for my local wireless lan. Unfortunately, the connection does not seem to work, I keep getting notifications that my wireless has disconnected (but none indicating that I've connected). When I examine syslog, it seems to indicate that I've successfully associated with the wireless switch and that dhcp has successfully acquired an ip address but the log shows that the dhcp process keeps sending requests, eventually dropping the connection. 'ifconfig wlan0' never shows the dhcp address logged in syslog. I suspect that the problem lies with the usb dongle, my configuration or the wireless switch but I am not certain how to isolate the problem, can anyone provide some insight on how I should go about homing in on the cause of this problem or verifying the functionality of the individual components, thanks.

    Read the article

  • Second network card configuration not working.

    - by Sebas
    I have 4 servers running Centos 5. All of them have two ethernet network cards. I have configured 192.168.1.x IP addresses on their eth0 card. They are all connected to the same switch using their eth0 card and they are all working. I have configured 10.72.11.x IP addresses on their eth1 card.They are all connected to the same switch - a different one from the switch used with eth0 card - using their eth1 card and they are NOT all working. Their configuration files is like: DEVICE=eth1 BOOTPROTO=static IPADDR=10.72.11.236 BROADCAST=10.72.11.191 NETMASK=255.255.255.192 NETWORK=10.72.11.128 HWADDR=84:2B:2B:55:4B:98 IPV6INIT=yes IPV6_AUTOCONF=yes ONBOOT=yes The interfase is starting and configured as I need. [root@sql1 network-scripts]# ifconfig eth0 Link encap:Ethernet HWaddr 84:2B:2B:55:4B:97 inet addr:192.168.1.105 Bcast:192.168.1.255 Mask:255.255.255.0 inet6 addr: fe80::862b:2bff:fe55:4b97/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:2981 errors:0 dropped:0 overruns:0 frame:0 TX packets:319 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:386809 (377.7 KiB) TX bytes:66134 (64.5 KiB) Interrupt:36 Memory:da000000-da012800 eth1 Link encap:Ethernet HWaddr 84:2B:2B:55:4B:98 inet addr:10.72.11.236 Bcast:10.72.11.191 Mask:255.255.255.192 UP BROADCAST MULTICAST MTU:1500 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:0 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:0 (0.0 b) TX bytes:0 (0.0 b) Interrupt:48 Memory:dc000000-dc012800 I also added a route-eth1 file that looks like: 10.0.0.0/8 via 10.72.11.254 Routing looks fine to me: [root@sql1 network-scripts]# netstat -rn Kernel IP routing table Destination Gateway Genmask Flags MSS Window irtt Iface 10.72.11.192 0.0.0.0 255.255.255.192 U 0 0 0 eth1 192.168.1.0 0.0.0.0 255.255.255.0 U 0 0 0 eth0 169.254.0.0 0.0.0.0 255.255.0.0 U 0 0 0 eth1 10.0.0.0 10.72.11.254 255.0.0.0 UG 0 0 0 eth1 0.0.0.0 192.168.1.1 0.0.0.0 UG 0 0 0 eth0 But I cannot ping one server from the other. [root@sql1 network-scripts]# ping 10.72.11.235 PING 10.72.11.235 (10.72.11.235) 56(84) bytes of data. From 10.72.11.236 icmp_seq=1 Destination Host Unreachable From 10.72.11.236 icmp_seq=2 Destination Host Unreachable From 10.72.11.236 icmp_seq=3 Destination Host Unreachable From 10.72.11.236 icmp_seq=4 Destination Host Unreachable From 10.72.11.236 icmp_seq=5 Destination Host Unreachable From 10.72.11.236 icmp_seq=6 Destination Host Unreachable ^C --- 10.72.11.235 ping statistics --- 7 packets transmitted, 0 received, +6 errors, 100% packet loss, time 6033ms , pipe 3 What am I doing wrong?

    Read the article

  • Laptop changes closing lid power options based on media/music playing

    - by Backdraft
    Hi, This is on a Lenovo X60 running Windows 7 Professional. This is just a pet peeve of mine, but I was wondering if it were somehow possible to have my laptop autodetect whether any media/music is playing on and change/switch the "Close lid" options under Power Options, ie. when something is playing change state to "Do Nothing" otherwise change state to "Sleep". I guess I can probably set a some key combo up with AutoHotKey to do it, but was hoping Windows could detect and switch my Power Options automatically. Thanks.

    Read the article

  • Issue with InnoDB engine while enabling and [ skip-innodb ]

    - by Ahn
    How to enable InnoDB, which was previously disabled with skip-innodb option. Case 1: Disabled the innodb with skip-innodb option and show engines givens as below. Engine | Support ... | InnoDB | NO ...... Case 2: As I want to enable the innodb, I commanded the #skip-innodb option and restarted. But now the show engines even not showing the InnoDB engine in the list. ? Mysql Version : 5.1.57-community-log OS : CentOS release 5.7 (Final) Log: 120622 13:06:36 InnoDB: Initializing buffer pool, size = 8.0M 120622 13:06:36 InnoDB: Completed initialization of buffer pool InnoDB: No valid checkpoint found. InnoDB: If this error appears when you are creating an InnoDB database, InnoDB: the problem may be that during an earlier attempt you managed InnoDB: to create the InnoDB data files, but log file creation failed. InnoDB: If that is the case, please refer to InnoDB: http://dev.mysql.com/doc/refman/5.1/en/error-creating-innodb.html 120622 13:06:36 [ERROR] Plugin 'InnoDB' init function returned error. 120622 13:06:36 [ERROR] Plugin 'InnoDB' registration as a STORAGE ENGINE failed. 120622 13:06:36 [Note] Event Scheduler: Loaded 0 events 120622 13:06:36 [Note] /usr/sbin/mysqld: ready for connections. Version: '5.1.57-community-log' socket: '/data/mysqlsnd/mysql.sock1' port: 3307 MySQL Community Server (GPL)

    Read the article

  • esx 4 - c7000 - cisco 3020

    - by gdavid
    I have 4 blades with esx 4 installed in a HP c7000 enclosure. They have 6 cisco 3020 for hp switches in the backend. The plan was to use 2 switches for iSCSI traffic and the other 4 for data traffic. I am having a problem trunking the switches to our existing environment. The documentation i keep finding online has commands/features that are not available on the 3020 switch. Does anyone have this setup anywhere? I am looking to do Virtual Switch Tagging (VST) so i can control the machines vlan via the port groups. The only time any configuration worked for us was when our network team placed the command switchport native vlan x this setup only allowed vlan x to pass traffic and only when the port group was in vlan 0. Ideas? thanks for any help. -GD

    Read the article

  • zero downtime during database scheme upgrade on SQL 2008

    - by eject
    I have web application on IIS7 with SQL server 2008 as RDBMS. Need get 0 downtime during future upgrades of ASP.NET code and DB schema as well. I need to get right scenario for this. I have 2 web servers and 2 sql servers and one http load balancer whcih allows to switch web backend server for web requests. Main goal is to make 1st web server and DB server up and running, update code and db schema on 2nd server and then switch all the requests to 2nd server and then main problem - how to copy data from 1st database 2nd (which was changed during upgrade).

    Read the article

  • How to have 2 windows machines on the same network with the same IP address

    - by Stu
    I have a custom made ADC device that is spitting out data by addressed UDP packets. I have that device plugged into a 4 port switch. I have one windows embedded standard 7 machine which is the normal recipient of that data. To be able to receive the data (Using LabVIEW) the windows network adapter IPv4 settings must have a static IP address that corresponds to the UDP packet destination. I would like to add a second windows machine (This one is just regular Win 7 Pro) to simultaneously catch the data, however with all devices connected to the switch, the Win 7 Pro machine recognizes an IP address conflict and will not take the setting for the required static IP address. (The network adaptor settings show that the correct value has been entered but ipconfig shows that it is not actually set.) Neither windows machine needs to transmit network data, they only need to be able to receive the UDP data from the ADC device. Is there any way to disable this IP address conflict detection 'feature' of windows networking?

    Read the article

  • Multicasting Windows 7 Image

    - by LawnChairSkank
    I am trying to deploy some new machines with windows 7 for the first time in our computer labs. We used to use third party imaging software and then run sysprep after the image was copied(XP), but it seems you can't go that route with windows 7. We set up a new imaging server with the windows system image manager, but when we try to multicast the image it pretty much takes down our whole staff and faculty network. I heard you can turn on a multicast feature on our cisco switches to help with the issue, but that it also slows the switches to a crawl. Another idea we have tried was pulling the the computer lab switch off the main network and plugging the imaging server directly into the computer lab switch so the multicast doesn't take down our network, but it doesn't seem to work without being able to hit a domain controller. Is there a way to multicast without taking out the network? I feel like I am missing something... Thanks in advance

    Read the article

  • Is it possible to use multi keyboards with multi keyboard layouts simultaneously?

    - by mono
    Considering to switch to dvorak layout, but this terminal is used by multi users as the same user account. It is unacceptable to ask all people to switch layout, plus it is hard to use dvorak layout with a keyboard qwerty-ly labeled. But there are spare (USB,qwerty) keyboards, so if I plug another keyboard in and be able to use multi layouts on different psyical keyboard simultaneously (I will rearrange letters on keys), the problem get solved. solution for either windows or linux is fine. anyway thanks all.

    Read the article

< Previous Page | 141 142 143 144 145 146 147 148 149 150 151 152  | Next Page >