  • Ubuntu - why would /var/log/dmesg stop updating after boot? does not show panic/cpu_hung errors which the console shows

    - by Tom G
    So I have an Ubuntu 10.04 install VM on a host. Latest 2.6.38-15-server kernel . /var/log/dmesg displays only the bootup but will stop recording after that. It will not show the trace/cpu_hung errors I am trying to troubleshoot. /var/log/dmesg.0 , dmesg.1 nothing - I did a string search for the text that displays on the console during the crash and NOTHING gets logged anywhere in /var/log/* . I have to call into the provider and ask them to take a screenshot of the console since nothing shows in dmesg. Why would /var/log/dmesg not record kernel panics, or such?

    Read the article

  • Windows Vista Help, OS Installation

    - by Darknight1366
    I've brought Vista Ultimate DVD from my friend, there was a .iso file. I extracted them and found two files(there was some boot files too) : boot.wim install.wim I extracted the boot.wim with WinMount. But I can't extracting the install.wim Should I Burn the whole files(extracted and past files) into a DVD Or, Should I try to extract the install.wim ???? I searched Google, some forums and websites said that the setup.exe can extract the install.wim before starting the Installation.(I found the setup.exe after extracting the boot.wim)

    Read the article

  • Cisco FC SAN switch decision

    - by Chopper3
    I've got to buy a bunch of FC SAN switches in the next week or so, I have to, and want to, buy Cisco MDSs. Servers are HP BL490c G6's in C7000 chassis with Virtual-Connect Flex-10 ethernet interconnects and VC FC interconnects (Emulex HBAs btw), all running ESX 3.5U4 (for now). I think I've only really got two choices; MDS 9509's with dual-supervisors with a single 48-port 4Gb FC card MDS 9222i's with single supervisor and the built-in 18-FC-port/4-GigE-FCIP-port option Both have the same functionality (I think, buying the enterprise licence btw), both have plenty enough performance and adequate ports for now and the next three years. The 9222i's are about 55% the price of the 9509's - logic says get the 'i's but will I really miss the dual-supervisors? I've got lots of 9509's with dual-supervisors that I'm very happy with but I'm not sure I've every benefitted from the dual-sups in the past and they are nearly twice the price - but if I don't buy them and miss them I can't retrofit them later. What are your thoughts?

    Read the article

  • see if cd is marked as bootable

    - by Crash893
    I am trying to install xp on a old laptop (compaq presario 700) with a stored verion of xp that i burn to an iso the copy of xp is legit but it won't boot to it. I am able to boot to the crap recover cd that is basically just dos and to a copy of "ultimate boot cd v5" that i just now downloaded and created from the same computer and burner that the xp cd was made from. everything boots but this xp cd. is there a way to tell if its boot-able

    Read the article

  • Misconfigured external monitor on Mac OS X Snow Leopard 10.6.3

    - by Mike
    I have an external monitor (specifically, an HDTV) hooked up to my 2.53GHz 13" macbook pro. This display works fine and I use it with my mac in clamshell mode (eg. with an external keyboard/mouse and the laptop closed and the built-in mac screen turned off) My Mac has multiple users on it. For User A I can use the mac with the external monitor in both clamshell and dual-monitor setups. For User B, I can use the monitor in a dual-monitor setup, but whenever I switch to clamshell mode the Mac switches to an incorrect output resolution or frequency setting that my HDTV doesn't recognize, resulting in a blank screen and a message about Unsupported Resolution. Chances are I did this to myself by misconfiguring my display settings at some point in the past, but I have no idea how to undo it. I (obviously) can't seen the display to change the settings when it's borked. I can see the display settings if I switch to Dual-monitor mode, but those settings only affect the dual monitor setup; no matter how I change the settings in dual-monitor mode, the clamshell mode setup remains borked. How can I dig myself out of this hole?

    Read the article

  • How to address a recurring low temperature error seen at every boot-up?

    - by GregC
    After updating to latest controller firmware, I started receiving the following error messages: LSI 2208 ROC: Temperature sensor below error threshold on enclosure 1 Sensors 5 thru 7 Is this something I should worry about, or is it a Red Herring? Details: I have a Sans Digital NexentaSTOR 24-disk JBOD enclosure connected to LSI 9286-8e RAID-on-Chip controller with two SAS cables. Seagate ES.2 3TB SAS hard drives populate every bay in the enclosure.

    Read the article

  • DAS vs SAN storage for serving 2 to 4 nodes

    - by Luke404
    We currently have 4 Linux nodes with local storage, arranged in two active/passive pairs with storage mirrored using DRBD, running virtual machines (actually using Xen Hypervisor) for typical hosting workloads (mail, web, a couple VPS, etc.). We're approaching the (presumed) maximum IOPS of those servers, and we're planning to migrate to an external storage solution with two active nodes, with capacity for up to four active nodes. Since we're an all-Dell shop I've done some research and found the MD3200 / MD3200i products should be the ones we're looking for. We are pretty sure we won't be attaching more than 4 hosts on a single storage and I'm wondering if there is any clear advantage for one or the other. In theory I should be able to attach 4 SAS hosts to a single MD3200 (single links on a single controller MD3200, or dual redundant SAS links from each host to a dual-controller MD3200), or 4 iSCSI hosts to a single MD3200i (directly on its 4 GigE ports without any switch, again with dual links for the dual controller option). Both setups should let us implement live VM migration since all hosts can access all the LUNs at the same time, and also some shared filesystem like GFS2 or OCFS2. Also, both setups should allow full redundancy of the whole system (assuming dual controllers in the storage). One difference I can see is that the DAS solution is actually limited to 4 hosts while the iSCSI one should be able to grow to more hosts (adding two GigE switches to the mix). One point for the iSCSI solution is that it would allow us to start out with our current nodes and upgrade them at a later time (we can't add other SAS controllers, but they already have 4 GigE ports each). With the right (iSCSI|SAS) controllers I should be able to connect diskless nodes and boot them off the external storage which I think is a good thing (get rid of any local storage). On the other hand, I would have thought the SAS one to be cheaper but it seems like an MD3200 actually costs a little less than an MD3200i (?) (please note: I've used Dell gear in my examples since that's what we're looking for but I assume the same goes with other vendors) I would like to know if my assumptions above are correct, and if I'm missing any important difference between the two setups.

    Read the article

  • Strange message during the Linux boot and slow start caused by "udevd[336] timeout ... "

    - by Kyrol
    When Debian (wheezy testing version) is loading, at a certain point appears a strange message: udevd[336] timeout usb_id--export /devices/pci0000:00/0000:00:1a.0/usb1/1-1/1-2.2/1-1.2:1.0 video4linux/ [502] after this message, start another message that loops for 120 secs: udevd[336] killing /devices/pci0000:00/0000:00:1a.0/usb1/1-1/1-2.2/1-1.2:1.0 video4linux/ [502] When the loop finish, Debian start normally and nothing seems to be "broken"! I also killed the loop with CTRL-C to break the loop and the system doesn't give any problem. Does anyone know a possible answer?

    Read the article

  • How do I get windows 7 to go full screen in boot camp?

    - by Ryan Michela
    I'm running Windows 7 on an iMac using Bootcamp. At the native resolution of 1290x1200, the desktop fills the entire screen, but when I run games at a lower resolution or reduce the suze of the desktop the visible area is reduced and a large black border surrounds the display. I want to run 1024x768 full screen, not letterboxed. Is there a way to do this? I suspect a problem with the drivers.

    Read the article

  • mdadm: Win7-install created a boot partition on one of my RAID6 drives. How to rebuild?

    - by EXIT_FAILURE
    My problem happened when I attempted to install Windows 7 on it's own SSD. The Linux OS I used which has knowledge of the software RAID system is on a SSD that I disconnected prior to the install. This was so that windows (or I) wouldn't inadvertently mess it up. However, and in retrospect, foolishly, I left the RAID disks connected, thinking that windows wouldn't be so ridiculous as to mess with a HDD that it sees as just unallocated space. Boy was I wrong! After copying over the installation files to the SSD (as expected and desired), it also created an ntfs partition on one of the RAID disks. Both unexpected and totally undesired! . I changed out the SSDs again, and booted up in linux. mdadm didn't seem to have any problem assembling the array as before, but if I tried to mount the array, I got the error message: mount: wrong fs type, bad option, bad superblock on /dev/md0, missing codepage or helper program, or other error In some cases useful info is found in syslog - try dmesg | tail or so dmesg: EXT4-fs (md0): ext4_check_descriptors: Block bitmap for group 0 not in group (block 1318081259)! EXT4-fs (md0): group descriptors corrupted! I then used qparted to delete the newly created ntfs partition on /dev/sdd so that it matched the other three /dev/sd{b,c,e}, and requested a resync of my array with echo repair > /sys/block/md0/md/sync_action This took around 4 hours, and upon completion, dmesg reports: md: md0: requested-resync done. A bit brief after a 4-hour task, though I'm unsure as to where other log files exist (I also seem to have messed up my sendmail configuration). In any case: No change reported according to mdadm, everything checks out. mdadm -D /dev/md0 still reports: Version : 1.2 Creation Time : Wed May 23 22:18:45 2012 Raid Level : raid6 Array Size : 3907026848 (3726.03 GiB 4000.80 GB) Used Dev Size : 1953513424 (1863.02 GiB 2000.40 GB) Raid Devices : 4 Total Devices : 4 Persistence : Superblock is persistent Update Time : Mon May 26 12:41:58 2014 State : clean Active Devices : 4 Working Devices : 4 Failed Devices : 0 Spare Devices : 0 Layout : left-symmetric Chunk Size : 4K Name : okamilinkun:0 UUID : 0c97ebf3:098864d8:126f44e3:e4337102 Events : 423 Number Major Minor RaidDevice State 0 8 16 0 active sync /dev/sdb 1 8 32 1 active sync /dev/sdc 2 8 48 2 active sync /dev/sdd 3 8 64 3 active sync /dev/sde Trying to mount it still reports: mount: wrong fs type, bad option, bad superblock on /dev/md0, missing codepage or helper program, or other error In some cases useful info is found in syslog - try dmesg | tail or so and dmesg: EXT4-fs (md0): ext4_check_descriptors: Block bitmap for group 0 not in group (block 1318081259)! EXT4-fs (md0): group descriptors corrupted! I'm a bit unsure where to proceed from here, and trying stuff "to see if it works" is a bit too risky for me. This is what I suggest I should attempt to do: Tell mdadm that /dev/sdd (the one that windows wrote into) isn't reliable anymore, pretend it is newly re-introduced to the array, and reconstruct its content based on the other three drives. I also could be totally wrong in my assumptions, that the creation of the ntfs partition on /dev/sdd and subsequent deletion has changed something that cannot be fixed this way. My question: Help, what should I do? If I should do what I suggested , how do I do that? From reading documentation, etc, I would think maybe: mdadm --manage /dev/md0 --set-faulty /dev/sdd mdadm --manage /dev/md0 --remove /dev/sdd mdadm --manage /dev/md0 --re-add /dev/sdd However, the documentation examples suggest /dev/sdd1, which seems strange to me, as there is no partition there as far as linux is concerned, just unallocated space. Maybe these commands won't work without. Maybe it makes sense to mirror the partition table of one of the other raid devices that weren't touched, before --re-add. Something like: sfdisk -d /dev/sdb | sfdisk /dev/sdd Bonus question: Why would the Windows 7 installation do something so st...potentially dangerous? Update I went ahead and marked /dev/sdd as faulty, and removed it (not physically) from the array: # mdadm --manage /dev/md0 --set-faulty /dev/sdd # mdadm --manage /dev/md0 --remove /dev/sdd However, attempting to --re-add was disallowed: # mdadm --manage /dev/md0 --re-add /dev/sdd mdadm: --re-add for /dev/sdd to /dev/md0 is not possible --add, was fine. # mdadm --manage /dev/md0 --add /dev/sdd mdadm -D /dev/md0 now reports the state as clean, degraded, recovering, and /dev/sdd as spare rebuilding. /proc/mdstat shows the recovery progress: md0 : active raid6 sdd[4] sdc[1] sde[3] sdb[0] 3907026848 blocks super 1.2 level 6, 4k chunk, algorithm 2 [4/3] [UU_U] [>....................] recovery = 2.1% (42887780/1953513424) finish=348.7min speed=91297K/sec nmon also shows expected output: ¦sdb 0% 87.3 0.0| > |¦ ¦sdc 71% 109.1 0.0|RRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRR > |¦ ¦sdd 40% 0.0 87.3|WWWWWWWWWWWWWWWWWWWW > |¦ ¦sde 0% 87.3 0.0|> || It looks good so far. Crossing my fingers for another five+ hours :) Update 2 The recovery of /dev/sdd finished, with dmesg output: [44972.599552] md: md0: recovery done. [44972.682811] RAID conf printout: [44972.682815] --- level:6 rd:4 wd:4 [44972.682817] disk 0, o:1, dev:sdb [44972.682819] disk 1, o:1, dev:sdc [44972.682820] disk 2, o:1, dev:sdd [44972.682821] disk 3, o:1, dev:sde Attempting mount /dev/md0 reports: mount: wrong fs type, bad option, bad superblock on /dev/md0, missing codepage or helper program, or other error In some cases useful info is found in syslog - try dmesg | tail or so And on dmesg: [44984.159908] EXT4-fs (md0): ext4_check_descriptors: Block bitmap for group 0 not in group (block 1318081259)! [44984.159912] EXT4-fs (md0): group descriptors corrupted! I'm not sure what do do now. Suggestions? Output of dumpe2fs /dev/md0: dumpe2fs 1.42.8 (20-Jun-2013) Filesystem volume name: Atlas Last mounted on: /mnt/atlas Filesystem UUID: e7bfb6a4-c907-4aa0-9b55-9528817bfd70 Filesystem magic number: 0xEF53 Filesystem revision #: 1 (dynamic) Filesystem features: has_journal ext_attr resize_inode dir_index filetype extent flex_bg sparse_super large_file huge_file uninit_bg dir_nlink extra_isize Filesystem flags: signed_directory_hash Default mount options: user_xattr acl Filesystem state: clean Errors behavior: Continue Filesystem OS type: Linux Inode count: 244195328 Block count: 976756712 Reserved block count: 48837835 Free blocks: 92000180 Free inodes: 243414877 First block: 0 Block size: 4096 Fragment size: 4096 Reserved GDT blocks: 791 Blocks per group: 32768 Fragments per group: 32768 Inodes per group: 8192 Inode blocks per group: 512 RAID stripe width: 2 Flex block group size: 16 Filesystem created: Thu May 24 07:22:41 2012 Last mount time: Sun May 25 23:44:38 2014 Last write time: Sun May 25 23:46:42 2014 Mount count: 341 Maximum mount count: -1 Last checked: Thu May 24 07:22:41 2012 Check interval: 0 (<none>) Lifetime writes: 4357 GB Reserved blocks uid: 0 (user root) Reserved blocks gid: 0 (group root) First inode: 11 Inode size: 256 Required extra isize: 28 Desired extra isize: 28 Journal inode: 8 Default directory hash: half_md4 Directory Hash Seed: e177a374-0b90-4eaa-b78f-d734aae13051 Journal backup: inode blocks dumpe2fs: Corrupt extent header while reading journal super block

    Read the article

  • Vista won't boot. BSOD: Page fault in nonpaged area

    - by user31576
    Here's the story: I let Windows Update do the updates it wanted to do, then rebooted the computer. The updating process was taking time so I went away. When I came back, my computer was rebooting. It got as far as the Windows logo with the laoding bar. BSOD'd. Rebooted. And I'm stuck in this loop ever since. Looked up on the net, the "Page fault in nonpaged area" seems to be linked to faulty RAM or drivers. So I ran a memory test, it found no error. When I try in safe mode (with promt) I can see a list of drivers being loaded, then I get the same BSOD. I tried to repair using the Vista DVD, it says "nothing to repair". I tried to restore to a previous state, it says "no restore point found". So, my guess is, it's got something to do with the drivers. How can I identify the one causing the BSOD? If you have any other leads, What can I do? By the way, I'm writing from this very computer, running a linux distro I installed after the BSOD loop started. So i guess it's not an hardware issue. I have backed up important data, and will format and reinstall Windows if I must. But I'd like to avoid that. Thanks in advance for any help you can give me.

    Read the article

  • Mount "Macrium Reflect" on a partition, boot from there ?

    - by b e
    Can Macrium's Reflect recovery CD be mounted/used with GRUB ? If the cd can be 'put' (loaded/mounted/...) in a partition, then the only disc needed would be the actual recovery disc, which could be on an external hard drive, or even on the same machine in another partition, thus allowing on to recover using only what's on the machine itself. I have WXPpro and Xubuntu8.04 double mounted, really happy with them together, use each right now to fix problems with the other when they come up. Also have a partition for the Reflect CD, but I just can't get it to load from Grub, which would be great... Thanks for any thoughts, probably someone has already done this I know !

    Read the article

  • How to swap ctrl and fn key on a MacBook Pro running Windows 7 via Boot Camp?

    - by hobbes3
    There are sooooo many discussion on the internet about swapping the fn and ctrl key on a MacBook Pro. On the Mac side, a new software called ReMap4MacBook does a perfect job swapping the two key. But on the PC side (specifically Windows 7), I can't really find a definitive answer. Most post refer to this article but I read the loooong article and followed the instructions to no avail. I remember there used to be a program (maybe it was on XP) that not only swapped the two keys but it also controlled the fans on the MacBook Pro. But I can't remember the name and I also recall that that program stopped being updated like years ago. EDIT: It's called Input Remapper. So I am hoping there exist a simple program that I can simply run to swap those two keys.

    Read the article

  • hiberfil.sys and pagefile.sys... rebuilt on boot?

    - by spender
    I need to take an image of a drive. I'm working from a bootable CD, so I have the option to decruft before taking the image. The Windows installation on the drive has both hyberfil.sys and pagefile.sys which I would rather not include in the image. If I delete these from the drive, will Windows recreate these files if necessary? EDIT The Windows installation on the drive in question was shut-down cleanly.

    Read the article

  • Methodologies for performance-testing a WAN link

    - by Chopper3
    We have a pair of new diversely-routed 1Gbps Ethernet links between locations about 200 miles apart. The 'client' is a new reasonably-powerful machine (HP DL380 G6, dual E56xx Xeons, 48GB DDR3, R1 pair of 300GB 10krpm SAS disks, W2K8R2-x64) and the 'server' is a decent enough machine too (HP BL460c G6, dual E55xx Xeons, 72GB, R1 pair of 146GB 10krpm SAS disks, dual-port Emulex 4Gbps FC HBA linked to dual Cisco MDS9509s then onto dedicated HP EVA 8400 with 128 x 450GB 15krpm FC disks, RHEL 5.3-x64). Using SFTP from the client we're only seeing about 40Kbps of throughput using large (2GB) files. We've performed server to 'other local server' tests and see around 500Mbps through the local switches (Cat 6509s), we're going to do the same on the client side but that's a day or so away. What other testing methods would you use to prove to the link providers that the problem is theirs?

    Read the article

  • DIMMs: Single vs. Double vs. Quad Rank

    - by MikeyB
    What difference does the 'Rank' of DIMMs make to server memory? For example, when looking at server configurations I see the following being offered for the same server: 2GB (1x2GB) Single Rank PC3-10600 CL9 ECC DDR3-1333 VLP RDIMM 2GB (1x2GB) Dual Rank PC3-10600 CL9 ECC DDR3-1333 VLP RDIMM Given the option of Single Rank vs. Dual Rank or Dual Rank vs. Quad Rank is one always: Faster? Cheaper? Higher Bandwidth?

    Read the article

  • Mount "Macrium Reflect" on a partition, boot from there?

    - by b e
    Can Macrium's Reflect recovery CD be mounted/used with GRUB ? If the cd can be 'put' (loaded/mounted/...) in a partition, then the only disc needed would be the actual recovery disc, which could be on an external hard drive, or even on the same machine in another partition, thus allowing on to recover using only what's on the machine itself. I have WXPpro and Xubuntu8.04 double mounted, really happy with them together, use each right now to fix problems with the other when they come up. Also have a partition for the Reflect CD, but I just can't get it to load from Grub, which would be great... Thanks for any thoughts, probably someone has already done this I know !

    Read the article

  • How can I load one image over network to multiple computers on boot?

    - by user754730
    A few years ago I saw this in a company but I don't know how it was built. There was 1 Computer (I don't know if Windows Server or plain Windows 7 - the server) and 3 other computers (Windows 7 - the clients). As soon as the Windows 7 clients were started, they all started up the same image (Don't know if the same image file or just the same state) over network and were able to work on the computer. As soon as the machine was shutdown, all the changes made to the system were erased. How could I build a system like this so I have 1 image file which I keep up to date and then feed it to the other machines in my network? It would look this this basically:

    Read the article

  • Collecting and viewing statistical data on website usage? Want to give Google Analytics the boot.

    - by amn
    I have always been somewhat reluctant to "outsource" site statistics to Google. We have an Apache server running on a Windows server. I am pretty sure all the foundation to collect the needed visitor data are there. I would like to stop using GA, and use some form of application where the data does not travel to a third party but remains at the host, or at least travels to the remote administrator, if it is a log analyzer in a browser. What are my options?

    Read the article

  • CPU running at full capacity when boot to DOS?

    - by Kevin H
    Does the CPU is run at 100% or near full capacity when the computer is booted into MS-DOS? Will the CPU temperature become higher even though we are not running any program in DOS mode? In Windows, we can see the CPU usage in % of utilization in Task Manager. From what I heard, CPU is running at near 100% capacity in DOS OS or in the BIOS MAIN screen. Is this caused by lack of CPU optimization in DOS OS?

    Read the article

  • How to measure startup time and order of Windows services on boot?

    - by djangofan
    I am not asking how to measure server startup time here. I am wondering if anyone knows of a tool that can measure and show a graph of the startup time and order of all the windows services during system startup. I saw a software program shown on my local Portland news last week that does this but I am unable to remember what it was called or anything else about it. All I remember is that it was a "tech" news story to help computer users with their computers. So, I know the software exists and I am trying to find it.

    Read the article

  • Can you boot/install/restore a MacBook Pro with a MacBook Air USB stick?

    - by zekel
    The new MacBook Airs don't have optical drives, so you can't install or restore the OS via DVD. They include a little USB stick for this purpose. I have a MacBook Pro and a MacBook Air. Does anyone know if it will work with my MacBook Pro? I'm thinking about removing my optical drive to put in another HD. The only sticky situation I might get into is if I need to do an install or restore on the road without an external DVD drive. (Good article on replacing optical drive with hard drive enclosure: remiel.info/post/1601242301/making-the-leap-to-ssd-on-a-macbook)

    Read the article