Search Results

Search found 58094 results on 2324 pages for 'http status codes'.

Page 168/2324 | < Previous Page | 164 165 166 167 168 169 170 171 172 173 174 175  | Next Page >

  • Why is ServerVariables["HTTP_REFERER"] skipping a page?

    - by Aaron
    Here is my situation: Page1.aspx redirects to Page2.aspx which does some processing (does not display to the user) and then redirects to Page3.aspx which checks the ServerVariables["HTTP_REFERER"] or Request.UrlReferrer. I understand that the referring information can sometimes be blank and can't be entirely relied upon; however the ServerVariables["HTTP_REFERER"] or Request.UrlReferrer on Page3.aspx is showing Page1.aspx instead of Page2.aspx which I would have expected. Does the referring information only get set if the page displays to the user? Redirecting is done using Response.Redirect in order to change the URL in the address bar of the browser.

    Read the article

  • In Spring MVC, is it possible to have different return types in one request handler method?

    - by Bobo
    For example, if a request succeeds, I will return a View ,if not, return a String indicating error message and set the content-type to either xml or json. Based on what I read, seems like I should use "void" as the return type for handler methods. Check this out: "void if the method handles the response itself (by writing the response content directly, declaring an argument of type ServletResponse / HttpServletResponse for that purpose) or if the view name is supposed to be implicitly determined through a RequestToViewNameTranslator (not declaring a response argument in the handler method signature)."(Spring Framework reference). What I dont understand is what " the view name is supposed to be implicitly determined through a RequestToViewNameTranslator (not declaring a response argument in the handler method signature)" means? Any anyone give me an example?

    Read the article

  • Is there a command-line tool that could tell me if Gzip is really on beyond the Gzip 1 header param?

    - by lucidquiet
    Is there a command-line tool that could tell me if Gzip is on? What I'm looking for is something that can say the stream coming from the server is really gzipped even if the header params say Gzip:1 (which it could be falsely placing in the headers). I don't see a switch in curl, or wget, or tcpdump, or anything, but maybe I'm just missing something, or perhaps there is something else that could provide me this bit of information? Any help would be appreciated.

    Read the article

  • How does one programmatically download files from the web?

    - by ytrp
    How are files downloaded from servers in programming languages like C? I understand higher level languages have magic functions like "download_file_from_url()" but they don't help me understand what is actually going on. I'm a little familiar with sockets but network programming in general is still a black box to me. Thanks for any help.

    Read the article

  • manage messages reported as spam

    - by parm.95
    I want to have an admin page to manage user messages reported as 'spam'. I know how to use MySql and php to have a list of messages reported but I don't know what is the more safe way to access to this page. Local, https,... What strategy use big websites as Facebook, MySpace,... to verify that a message is a true spam and to delete it?

    Read the article

  • Need to include #anchor after querystring list

    - by Bloopy
    Hello, Form is 'get' to a API which operates off of querystring. One of the parameters is a PackageID which indicates a vacation package. In order for the packageID to appear I also need to append '#packages' to the end of the get request. Since not all form 'get' have a package I need this to be dynamic. I've tried adding a hidden field with '#packages' as the value - however the '#' is automatically encoded and therefore not registered when the server grabs the URL. What would be the best way for me to dynamically include '#packages' as it appears in the querystring via javascript? Thanks!

    Read the article

  • Should an edit of a comment be sent through POST or PUT?

    - by the_drow
    I have the following URI: Posts/{postId}/Comments/{commentId} I would like to enable users to edit a comment through my API, should the edit be done with POST or PUT? One one hand, POST updates the contents of a resource so that makes sense but on the other hand PUT replaces it with a new one. So if I understand correctly with POST I need to send only what needs to be updates and with PUT I send the whole resource. Usually in edit forms, the whole resource is loaded anyway so what's the point of using POST? If I take one approach or the other, what are the differences?

    Read the article

  • Break the limit of threading, segmentation fault

    - by user353573
    use pthread_create to create limited number of threads running concurrently Successfully compile and run However, after adding function pointer array to run the function, Segmentation fault Where is wrong? workserver number: 0 Segmentation fault void* workserver(void arg) { int status; while(true) { printf("workserver number: %d\n", (int)arg); ( job_queue[(int)arg])(); sleep(3); status = pthread_mutex_lock(&data.mutex); if(status != 0) printf("%d lock mutex", status); data.value = 1; status = pthread_cond_signal(&data.cond); if(status != 0) printf("%d signal condition", status); status = pthread_mutex_unlock(&data.mutex); if(status != 0) printf("%d unlock mutex", status); } }

    Read the article

  • Sending two servlet responses per request

    - by sangi
    Hi, I write, because I can not solve the following problem. I have a servlet that processes some information. In response I put both text and binary content. How do I get two response, then two html page, starting from the same request? is a thing possible? The first response should continue to do what he does now, while the second would appear to make a popup window to save an image. There are easier ways to achieve the same result? Many thanks in advance

    Read the article

  • Why does php's file_get_contents incorrectly retrieve json files from xkcd?

    - by hally
    In writing a PHP script to download xkcd comics, i incurred errors when trying to get specific comics (as opposed to the latest one). Specifically, pointing file_get_contents at the following url: xkcd.com/$COMIC_NUM/info.0.json inexplicably retrieved the xhtml version of the comic's page on xkcd.com, and not a JSON file. However, if i request the exact same url in my browser, the correct JSON file is downloaded. I'm not sure why this is happening, but i suspect it has something to do with the request headers being sent. Please help! :S

    Read the article

  • determine if user is using proxy

    - by jefffan24
    Hi I'm creating a game and I would like to be able to tell if a user is using a proxy. If they are than it basically puts a flag on their account. I can make it do the flag and all but I'm not exactly sure how to tell if a user is using a proxy. I've seen you can use headers but I'm not exactly sure which to look for and how you would check if a user "has" a header (besides the normal http_referrer and what not). Any help is greatly appreciated.

    Read the article

  • [.NET][C#] - Is possible to get a web with its links (CSS,JavaScript,Images, CSS-Images) ?

    - by Efrain
    Hi there, I am implementing a CMS, the case is that the "Web-Editable" is in a different domain thus, I would be able just get the page using HttpRequest in order to copy and show it in the CMS server to make it able to change it (DOM just visual purpose) and save the changes to the CSS and JavaScript folder on the "Web-Editable" using FTP. I am not allow to download all the information included on the "Web-Editable" trough the FTP, and there are other dinamic images as well comming from a private database. The question is, anyone knows how to make a httprequest "cascade" to get all the 1st level information you see when you visit a Web? Thank you in advance, Efrain

    Read the article

  • $.ajax + authentication + `@` in username

    - by Koning Baard XIV
    I am creating a web app which uses jQuery to authenticate: $.ajax({ url: "/session/create?format=json", type: "GET", dataType: "json", cache: false, username: $("#signin-email").val(), password: $("#signin-password").val(), success: function(data) { if(data.success) { success = true; } } }); The problem is that the code only makes the AJAX-request when the username does not include things like an @, which is required in my app. Can anyone help me with how I can do this? I do not mind changing the back-end a little bit, but requiring users to have an @-less email is not an option. Oh, my back-end is a Ruby-on-Rails app

    Read the article

  • Multiple requests to server question

    - by embedded
    I have a DB with user accounts information. I've scheduled a CRON job which updates the DB with every new user data it fetches from their accounts. I was thinking that this may cause a problem since all requests are coming from the same IP address and the server may block requests from that IP address. Is this the case? If so, how do I avoid being banned? should I be using a proxy? Thanks

    Read the article

  • HTML actual page link

    - by lore3d
    Hi all, I'm building a website, and i need to know the actual page address in which the user is in, in order to take users in the same page after login. The problem is that every page is generated from variables passed by url and query string, so I dont't know how to recover every variable and assign to it the correct value. How to recover variables name and assign them the correct values? Thanks lore (sorry for my English)

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • Domino HTTP Server: Error - Unable to Bind 1.2.3.4, port 80, port in use or Bind To Host configuration specifies a duplicate IP address/host

    - by pdewaard
    We have a Domino 9.0.1 Server hosted on Ubuntu 14.04 Server, which hosts several other http based Tasks, (Nginx, Couchdb, Confluence on Tomcat). The Ubuntu Server has multiple IPs, all bind correctly to the different Tasks. The Domino SMTP task binds correctly and is working well. All http tasks (other than Domino) are proxied behind Nginx version 1.6x and all are working well, netstat shows no 0.0.0.0 bindings, no one is listening on 1.2.3.4:80 . when I try to load http on the (Domino) server console it failes with HTTP Server: Error - Unable to Bind 1.2.3.4, port 80, port in use or Bind To Host configuration specifies a duplicate IP address/host a couple of times, may be 4 or 5 times then it loads without failure! And: when it comes up, I see http is listening on 80 AND 443, but SSL Connections are not working, nor any error log! It must be a kind of bad magic :-( thanks in advance Pitt

    Read the article

  • .htaccess to redirect any URL from a domain to a fixed URL on another domain

    - by AlexV
    Anyone can help me out with an .htaccess I'm trying to create? I want to redirect foo.com to foo.ca. Any URL from foo.com (with or without www and under http or https) will all be redirected to www.foo.ca. Some examples: http://www.foo.com/ -- http://www.foo.ca/ (http + www) https://www.foo.com/ -- http://www.foo.ca/ (https + www) http://foo.com/bar/ -- http://www.foo.ca/ (http + some url) https://foo.com/bar/ -- http://www.foo.ca/ (https + some url) http://www.foo.com/bar/ -- http://www.foo.ca/ (http + www + some url) https://www.foo.com/bar -- http://www.foo.ca/ (https + www + some url) Many thanks!

    Read the article

  • Postfix how to triggering my script when outgoing email status is sent?

    - by Laszlo Malina
    I want to run a program when postfix has successfully sent out a mail (local or remote). I would like to pass the headers to program and if possible also the destination ip or address (exclude spam filter delivery). I just have an idea: Delivery Status Notification processing via uniqe transport program, but I'd prefer the above. My goal is to be recorded lifetime (events) of email: it came, it went out (from, to, subject, datetime, message id, message status: bounce, sent). I would only need the state of the outgoing mail, because incoming and bounce program is working. It is possible to trigger a program (similar to a transport pipe/spawn) or DSN "cheat" stay? Thanks in advance for any reply!

    Read the article

  • Linux service --status-all shows "Firewall is stopped." what service does firewall refer to?

    - by codewaggle
    I have a development server with the lamp stack running CentOS: [Prompt]# cat /etc/redhat-release CentOS release 5.8 (Final) [Prompt]# cat /proc/version Linux version 2.6.18-308.16.1.el5xen ([email protected]) (gcc version 4.1.2 20080704 (Red Hat 4.1.2-52)) #1 SMP Tue Oct 2 22:50:05 EDT 2012 [Prompt]# yum info iptables Loaded plugins: fastestmirror Loading mirror speeds from cached hostfile * base: mirror.anl.gov * extras: centos.mirrors.tds.net * rpmfusion-free-updates: mirror.us.leaseweb.net * rpmfusion-nonfree-updates: mirror.us.leaseweb.net * updates: mirror.steadfast.net Installed Packages Name : iptables Arch : x86_64 Version : 1.3.5 Release : 9.1.el5 Size : 661 k Repo : installed .... Snip.... When I run: service --status-all Part of the output looks like this: .... Snip.... httpd (pid xxxxx) is running... Firewall is stopped. Table: filter Chain INPUT (policy DROP) num target prot opt source destination 1 RH-Firewall-1-INPUT all -- 0.0.0.0/0 0.0.0.0/0 Chain FORWARD (policy DROP) num target prot opt source destination 1 RH-Firewall-1-INPUT all -- 0.0.0.0/0 0.0.0.0/0 Chain OUTPUT (policy ACCEPT) num target prot opt source destination Chain RH-Firewall-1-INPUT (2 references) ....Snip.... iptables has been loaded to the kernel and is active as represented by the rules being displayed. Checking just the iptables returns the rules just like status all does: [Prompt]# service iptables status Table: filter Chain INPUT (policy DROP) num target prot opt source destination 1 RH-Firewall-1-INPUT all -- 0.0.0.0/0 0.0.0.0/0 Chain FORWARD (policy DROP) num target prot opt source destination 1 RH-Firewall-1-INPUT all -- 0.0.0.0/0 0.0.0.0/0 Chain OUTPUT (policy ACCEPT) num target prot opt source destination Chain RH-Firewall-1-INPUT (2 references) .... Snip.... Starting or restarting iptables indicates that the iptables have been loaded to the kernel successfully: [Prompt]# service iptables restart Flushing firewall rules: [ OK ] Setting chains to policy ACCEPT: filter [ OK ] Unloading iptables modules: [ OK ] Applying iptables firewall rules: [ OK ] Loading additional iptables modules: ip_conntrack_netbios_n[ OK ] [Prompt]# service iptables start Flushing firewall rules: [ OK ] Setting chains to policy ACCEPT: filter [ OK ] Unloading iptables modules: [ OK ] Applying iptables firewall rules: [ OK ] Loading additional iptables modules: ip_conntrack_netbios_n[ OK ] I've googled "Firewall is stopped." and read a number of iptables guides as well as the RHEL documentation, but no luck. As far as I can tell, there isn't a "Firewall" service, so what is the line "Firewall is stopped." referring to?

    Read the article

< Previous Page | 164 165 166 167 168 169 170 171 172 173 174 175  | Next Page >