Search Results

Search found 3033 results on 122 pages for 'manual'.

Page 18/122 | < Previous Page | 14 15 16 17 18 19 20 21 22 23 24 25  | Next Page >

  • Biml Workshop presented by Varigence and Linchpin People

    Business Intelligence Markup Language (Biml) automates your BI patterns and eliminates the manual repetition that consumes most of your time. On October 15th come see why BI professionals around the world think Biml is the future of data integration and BI. Need to compare and sync database schemas?Let SQL Compare do the hard work. ”With the productivity I'll get out of this tool, it's like buying time.” Robert Sondles. Download a free trial.

    Read the article

  • ATI card - cannot set refresh rate higher than 60 Hz

    - by KubaV
    I am trying to set refresh rate to 85 Hz or 75 Hz at 1024x768 and 1280x1024. On Windows this works, so my card and monitor have 100% support. xrandr does not work - it gives me configure crtc 1 failed I use FGLRX. Please help Monitor:CRT - HP 92 (manual http://bizsupport2.austin.hp.com/bc/docs/support/SupportManual/lpv09818/lpv09818.pdf) G. card: AMD Radeon HD 6450 Sorry for bad english, I am Czech.

    Read the article

  • i got mysql error on this statement i don't know why [closed]

    - by John Smiith
    i got mysql error on this statement i don't know why error is: #1064 - You have an error in your SQL syntax; check the manual that corresponds to your MySQL server version for the right syntax to use near 'CONSTRAINT fk_objet_code FOREIGN KEY (objet_code) REFERENCES objet(code) ) ENG' at line 6 sql code is CREATE TABLE IF NOT EXISTS `class` ( `numero` int(11) NOT NULL AUTO_INCREMENT, `type_class` varchar(100) DEFAULT NULL, `images` varchar(200) NOT NULL, PRIMARY KEY (`numero`) CONSTRAINT fk_objet_code FOREIGN KEY (objet_code) REFERENCES objet(code) ) ENGINE=InnoDB;;

    Read the article

  • What package (helper app) does recoll need to index images?

    - by hobs
    The File->Show_missing_helpers menu item in the recoll GUI mentions the following missing helper (among others): Perl::Image::ExifTool (image/gif image/jpeg image/png image/tiff image/x-xcf) Per the recoll user manual I installed the perl image exif tool (and library): sudo aptitude install libimage-exif-perl libimage-exiftool-perl but recoll still lists the missing helper and fails to index images. uname -a: Linux AlSSD 3.2.0-30-generic #48-Ubuntu SMP Fri Aug 24 16:52:48 UTC 2012 x86_64 x86_64 x86_64 GNU/Linux

    Read the article

  • What are the differences between Special Edition and the Third Edition of Stroustrup's The C++ Programming Language?

    - by TheBlueCat
    I'm buying a few C++ books after moving from Java. I obviously want to read the reference manual from the man himself, though I cannot tell the difference between these two editions. The special edition is ten pages shorter than the third edition. However, the special edition is recommended over the third edition and it seems this version covers the ASCII standard when the other edition does not. Can anyone shed a bit of light on this?

    Read the article

  • Productivity strategies for one developer using many PCs

    - by DeveloperDon
    In a talk about time management, a famous computer scientist said: "One machine in your life is the right number." He recommended a laptop with a docking station. After trying this approach for about a month, I miss my more powerful desktop (i7 quad core hyperthread), but it is not in my technology road map (or budget) to upgrade from my old Intel Core 2 Duo (2006) notebook this year. What strategies can help me use the desktop while at my desk and without much manual effort the notebook when I am on the go?

    Read the article

  • What's the simplest way to create a page with dynamic elements?

    - by ElendilTheTall
    I'm developing a site, part of which lists training courses with dates and prices. Every year the dates and prices change, which would mean loads of manual code editing to update the pages. What I'd like to do is have a database containing the relevant information, which the course pages then reference, so we can just update the database rather than the HTML. My experience lies in static design - so, what is a simple way to achieve this?

    Read the article

  • When will Ubuntu migrate to GTK+ 3.0?

    - by Moma Antero
    Hello, I just got known that GTK+ 3.0.0 has been released. Will Ubuntu 10.10/11.04 come with runtime libraries for GTK+ 3.0? Are these installed by default? Will Ubuntu have development libraries and header files for compilation of GTK+ 3.0 programs? When will Ubuntu (as whole) move to GTK 3? I'm mostly concerned about moving audio-recorder app from GTK+ 2.x to 3.0. References: Migrating from GTK+ 2 to GTK+ 3 guide GTK+ 3 Reference Manual:

    Read the article

  • Standardize SQL Server Installations with Configuration Files

    If you have a requirement to install multiple SQL Server instances with the same settings, you most likely want to do it without following the numerous manual installation steps. The below tip will guide you through how to install a SQL Server instance with less effort. The Future of SQL Server MonitoringMonitor wherever, whenever with Red Gate's SQL Monitor. See it live in action now.

    Read the article

  • llustrated C# 2010 - ISBN 978-1-4302-3282-7 Further comments

    - by TATWORTH
    I am now halfway through readign this books and I continue to be favourably impressed by it. It includes many of the new features of C# 4.0, including one that was new to me. This is a very good C# language manual and I have no hesitation in recommending it both to individuals and to C# development teams.  It is good for those learning C# and for those with years of experiance of C#. You can buy a copy online at http://www.apress.com/book/view/143023282X

    Read the article

  • Supermicro BIOS recovery - SUPER.ROM

    - by Goyuix
    I have a Supermicro X9SCL+-F motherboard that I flashed a beta BIOS to, then the flash went bad when I tried to flash back to the latest stable. I am attempting to recover using their SUPER.ROM recovery from a flash drive without success. I read in the manual that if I hold down Ctrl +Home  while powering on the server I can do a BIOS recovery from a flash drive. I hold down those keys, hear the desired two beeps and I can see the activity LED on the flash drive activate. Unfortunately, instead of the monitor turning on and allowing a BIOS recovery as the manual indicates, I hear five beeps, followed shortly after by 3 beeps. I grabbed the latest BIOS from their site (x9scm2.508.zip) and extracted it to my flash drive and renamed it to SUPER.ROM. Their instructions are not clear if any ROM can serve as the SUPER.ROM file, or if I need a special SUPER.ROM file to initiate the recovery at which time I can supply a known good ROM. Does anyone have any expertise in ROM recovery for Supermicro boards? Am I missing some key step? Can any known good ROM file function as the SUPER.ROM file for recovery?

    Read the article

  • Problems setting NTP sever with w32tm for a DC that is a Hyper-V guest

    - by R.Tonheim
    Hello ! I have tried to sett my DC to get its time from several NTP severs. I follow this answer (http://serverfault.com/questions/24298/w32time-sync-problems-for-hyper-v-guests-w32time-event-ids-38-24-29-35/24299#24299) to do it. First I disable Time Synchronization in the Hyper-V Integration Services for each guest. Then restart the Windows Time serviceon the guest. I had before this used this command: w32tm /config /manualpeerlist:"ntp.uio.no;timekeeper. uio.no;nissen.uio.no;0.no.pool.ntp.org;1.no.pool.ntp.org;2.no.pool.ntp.org" /syn cfromflags:manual /reliable:yes /update And the cmd sad: The command completed successfully. But the time was still 10 min wrong... I run w32tm again after restarted the DC without it having any effect. The w32tm /query /status still say: "Source: Local CMOS Clock" FROM MY CMD: Microsoft Windows [Version 6.0.6002] Copyright (c) 2006 Microsoft Corporation. All rights reserved. C:\Users\Administrator.MHGw32tm /query /status Leap Indicator: 0(no warning) Stratum: 1 (primary reference - syncd by radio clock) Precision: -6 (15.625ms per tick) Root Delay: 0.0000000s Root Dispersion: 10.0000000s ReferenceId: 0x4C4F434C (source name: "LOCL") Last Successful Sync Time: 05.09.2009 20:06:21 Source: Local CMOS Clock Poll Interval: 6 (64s) C:\Users\Administrator.MHGw32tm /config /manualpeerlist:"ntp.uio.no;timekeeper. uio.no;nissen.uio.no;0.no.pool.ntp.org;1.no.pool.ntp.org;2.no.pool.ntp.org" /syn cfromflags:manual /reliable:yes /update The command completed successfully. C:\Users\Administrator.MHGw32tm /query /status Leap Indicator: 0(no warning) Stratum: 1 (primary reference - syncd by radio clock) Precision: -6 (15.625ms per tick) Root Delay: 0.0000000s Root Dispersion: 10.0000000s ReferenceId: 0x4C4F434C (source name: "LOCL") Last Successful Sync Time: 05.09.2009 20:06:21 Source: Local CMOS Clock Poll Interval: 6 (64s) C:\Users\Administrator.MHG

    Read the article

  • RAID1 Broken Mirroring

    - by Sanoj
    I'm having a little server with Windows Small Business Server 2003. I'm using RAID1, via a HighPoint Rocket RAID 1640 RAID-card, using two harddrives. This week the server alarmed, and durig reboot I got the error-message Broken Mirroring (User Manual page 30). I had a few alternatives (see the manual), first I tried Continue, but the server restarted during boot. Next time I took Power Off, and replaced the oldest harddrive with a new one, and when I booted, I selected Rebuild. Then I selected the new harddrive to be the new one. The rebuild-procedure started and a progress bar at 0% showed up, but after a few seconds I got the message Copy Failed!, then the server booted and Windows Server started. Now it works fine. But I guess that I'm just using one harddrive now, and it's not mirrored. I haven't touched the server since then (two days ago). What should I do now? I have no experience of this situation. Anyone that have some guidance?

    Read the article

  • How to configure Farsun USB barcode scanner to not auto-trigger

    - by David Grayson
    At my company we have several USB barcode scanners. I'm not sure exactly what model they are, but I think they are the FG9800 from Farsun because that's what they look like on the exterior. They came with a programming manual that is very similar to this document from the Farsun website. When I scan the "Output Firmware Version" barcode, my scanner types the following into the computer: Farsun V2.00 2011-01-01 Is it possible to configure these scanners so they only read barcodes in response to the trigger button being pressed? I don't want them to automatically read barcodes. Additionally, I want this setting to be remembered while the scanner is turned off. Since this scanner only has a USB port, the only way to configure it that I know of is to scan bar codes from the manual (or make your own). I have tried scanning the configuration bar codes for Single Scan (013300), Single Scan No Trigger (013301), and Laser/CCD Timeout - 5 Seconds (0134005) from this document. Sometimes (but not often) this puts the scanner in to the right mode, where it only scans when the button is pressed. Unfortunately, the scanner seems to always leave this mode when it is power cycled. I have also scanned the "Reset Configuration To Defaults" barcode (0B) many times. We have three different scanners like this and I have not been able to successfully configure any of them. If the things I want are not possible with these Farsun-based scanners, is there some other scanner we can use?

    Read the article

  • Connect bluetooth headphones both to PC and phone at the same time

    - by Sergiy Byelozyorov
    I have recently bought Philips SHB6110. Extract from the 13th page of manual: Therefore you can connect your Bluetooth stereo headset. with a Bluetooth stereo enabled phone to both listen to music and lead calls, or with a Bluetooth phone that does not support Bluetooth stereo (A2DP) to lead calls and at the same time to a Bluetooth audio device (Bluetooth enabled MP3 player, Bluetooth audio adapter etc.) to listen to music. Make sure to pair the phone first with your Bluetooth headset, then turn both the phone and headset off to then pair the Bluetooth audio device. With the SwitchStream feature you can listen to music and monitor your calls at the same time. Even while listening to music, you will hear a ring tone when receiving a call and can switch to the call simply by tapping the button. The manual however doesn't specify how do I connect to both device at the same time. I use Toshiba Satellite Pro P300-1CG laptop with Belkin Mini Bluetooth Adapter and Nokia N95 phone. Operating system is Windows 7 64-bit and I have Skype installed. Both phone and compute can be used for listening to music and talking on the phone (on PC via Skype). Best solution would be if I could connect to PC and phone as the same time and monitor calls both mobile and Skype calls while listening music from Winamp. If that is not possible, then I would like at least to be able to listen music from PC, while monitoring calls from mobile. So, please tell me how do I connect both PC and phone to headphones?

    Read the article

  • Word 2007 textbox management

    - by TheSavo
    I am updating a user manual that was initially written by somebody else. I know that most manuals are not written in Word, but our office only uses Microsoft Office applications. I am doing fairly well, creating and applying "styles". A lot of the directions in this manual require updated screenshots of the program it documents. … It's a big mess. </rant> One thing I am attempting to do is add “call outs” or Note text boxes like those seen in modern software manuals. I am attempting to do this with the Text box feature. However, I am having a hard time making them uniform in size and positioning. Does Word offer a way to manage the size and other properties of textboxes, similar to the way it allows you to manage text in styles? I feel that this could (or should) be possible. Is it possible to manage Text Boxes the same way you can manage styles?

    Read the article

  • Where do I connect the HDD LED wires on my RAID adapter?

    - by Giffyguy
    I'm using a Promise FastTrak TX8660 with RAID 5. The manual (and Google) just doesn't seem to explain how exactly to connect a standard two-pin HDD LED wire to the eight available pins on the card. The Manual just says - To connect your LED, follow the following diagram: The card itself resembles the diagram: But it doesn't make any sense to me. All I have is a two-pin connecter for HDD LED on the front of my computer case. I don't need anything fancy like the fault LED or seperate indicators for each drive. I just want to be able to see when my RAID 5 array is working, that's all. I don't know what the "R" and "G" stand for, but my HDD LED wires are red and white. I tried connecting the red wire to the "R" pin and the white wire to the "G" pin, but that just makes the LED on the front of my case light up indefinitely, even when the computer is idle. Which pins am I suppose to connect the HDD LED header to for basic activity indication?

    Read the article

  • Postfix rewrite sender: why doesn't this work

    - by Nick Coleman
    I have server A with an IP address only and a dummy FQDN (on the basis all machines should have a FQDN): pants.net.invalid. All mail is relayed through another server elsewhere, which works fine. On server A, Postfix rewrites the sender address with smtp_generic_maps = hash:/etc/postfix/generic. According to the Rewrite manual at http://www.postfix.org/ADDRESS_REWRITING_README.html#remote, this should rewrite all outgoing external mail's Sender address: $ cat /etc/postfix/generic @pants.net.invalid [email protected] but it does not. postmap -q [email protected] returns nothing. This works: [email protected] [email protected] It seems as though it is doing regex matching even though I specify type hash:. Clearly I am misunderstanding the manual. I don't want to use regex or pcre expressions because there are only a couple of users (root and two others) and I don't want the overhead. I can specify the users exactly and it works. But, I would like to know what I am misunderstanding for future reference. Thanks.

    Read the article

  • Block protect (Keep last line of paragraph with next paragraph)

    - by Ed Cottrell
    Is there a way to force Microsoft Word 2010 to keep the last line of a paragraph with the next paragraph? An example of when this is relevant is when starting a block quote; it doesn't look good to have the block quote start at the top of a new page, particularly when it's introduced by a partial sentence, like this: "Lorem ipsum" is sample text widely used in the publishing industry, as the text has spacing roughly similar to that of English and therefore looks "normal" but unintelligible to an English reader's eye, allowing the reader to focus on design elements. It begins, Lorem ipsum dolor sit amet, consectetur adipiscing elit. Nam rhoncus laoreet risus, quis congue leo viverra congue. Suspendisse magna massa, viverra imperdiet est eu, ultrices volutpat lectus. Sed pulvinar est id risus lobortis venenatis. There shouldn't be a page break after "begins," because it looks like the sentence ends abruptly. "Keep lines together" won't work, because by definition we're talking about two paragraphs. "Keep with next" won't work if the first paragraph is larger than a couple of lines, because then you get an awkwardly large space at the bottom of a page. Manual line breaks obviously work, but only when the document is final, which is often less certain than it seems. I know WordPerfect has a feature called "block protect" that does this, but I have not found even an acceptable substitute in Word. I have played with style separators and hidden paragraph breaks, but to no avail. I would love a special character, kind of like the nonbreaking space or zero width optional space, that tells Word to move to the next page if the next paragraph would otherwise start the page. A macro would also be great, but I haven't been able to find a starting point (like how to detect where non-manual page breaks fall). Edit: It looks like "Keep with next" works this way in Word 2013, but I specifically need a fix that works in Word 2010.

    Read the article

  • Instabilities with Bridged and bonded interfaces

    - by Henry-Nicolas Tourneur
    I did post yesterday to get a working setup with several bridged interfaces used for virtual machines (KVM/libvirt). One of the bridged interface is just using eth3 as its ports while the second one (public traffic) is using an ethernet bonded interface. That setup is working but not all the time ! I can start a download from a vm, then it will stop and freeze! So I don't know if my bridge parameters are correct, could you check the below config ? iface eth3 inet manual auto bond0 iface bond0 inet manual slaves eth1 eth2 pre-up ip link set bond0 up down ip link set bond0 down auto br0 iface br0 inet static address 10.160.0.7 netmask 255.255.255.128 bridge_ports eth3 bridge_fd 9 bridge_hello 2 bridge_maxage 12 bridge_stp on auto br0:1 iface br0:1 inet static address 10.160.0.9 netmask 255.255.255.255 auto br0:2 iface br0:2 inet static address 10.160.0.10 netmask 255.255.255.255 auto br1 iface br1 inet static address 217.4.40.242 netmask 255.255.255.240 gateway 217.4.40.241 pre-up /etc/network/firewall start bridge_ports bond0 bridge_fd 9 bridge_hello 2 bridge_maxage 12 bridge_stp on auto br1:1 iface br1:1 inet static address 217.4.40.252 netmask 255.255.255.255 auto br1:2 iface br1:2 inet static address 217.4.40.253 netmask 255.255.255.255 And yes, it also sometimes speaks about martian on the host: kernel: [249146.055172] martian source 10.160.0.17 from 10.160.0.10, on dev vnet2 kernel: [249146.073122] ll header: ff:ff:ff:ff:ff:ff:54:52:00:76:c3:5c:08:06

    Read the article

  • Monitor reset itself and now I can't set the resolution/settings back to how it was before

    - by verve
    I've had my LG 24" widescreen monitor since 2009 and 2 weeks ago I noticed the monitor turned itself off (never had it done this before) so I switched it back on to find all the settings like gamma, resolution etc. different = looked like it had been reset. Everyone in the house swears they never unplugged and plugged it back in. When I opened a webpage the fonts and zoom on the pages were different and my desktop was strange too; fonts of the icons were different etc. The screen seems blurry and when I watch movies the faces look distorted so I thought I would try to first figure out the resolution it used to be but when I go under "Adjust screen resolution" none of the options work and there is no recommended resolution marked; all the options stretch out the screen and looks terrible so right now I have it set to the least distorted one. Then since the resolution wasn't working I set the other manual settings(done by physical buttons on the monitor) back to how it used to be (luckily, I had written these down). The monitor looks better but the resolution makes it a strain to use. I thought maybe some Windows update caused this crap so I tried to System Restore: didn't work. What went wrong? A few questions: 1) What was the likely cause of the monitor shutting down itself and screwing up the settings I have been using since the day I bought the monitor? 2) Why have the fonts changed everywhere unless this is a HDD/video card problem? 3) How do I find the perfect resolution it used to be? The monitor wants me to set it to 1920 x 1080 but that isn't one of the options although I don't remember what resolution I used before. I use the 16:9 setting while I try the available resolution options but nothing looks good! How do I find what it used to be? Manual available in PDF under Support: http://www.lg.com/ca_en/computer-products/monitors/LG-lcd-monitor-W2442PA-BF.jsp Win 7. IE 9.

    Read the article

  • JSP Content Issue in Tomcat

    - by gautam vegeta
    There is one application where I work where there are still manual builds used i.e manually moving the servlet classes and jsp files from Dev to QA and finally to Prod. This is the method used in this application which cant be changed for some wierd reasons.BTW this is not the problem. We did a manual build where we transferred jsp files from QA to PROD recently. And we noticed that the jsp file content does not correspond to the updated jsp's but have the same content to the jsp file which was present in the server prior to the deployment. We did not re-start tomcat since jsp files upon updation automatically changes its contents. This problem persisted even after 6 hours of deployment If we consider the time standards which are different which may cause some delay. So to fix this we had to individually go into every jsp file and just type something save it and delete this change and save it.Then it worked perfectly. But finally the jsp file content before and after was never changed we just did this to change the modification date. If we think in terms of timestamp problem how can this be possible coz the old jsp files which were present in the server prior to deployment was atlest one month old and the ones getting deployed were defenitely newer than that. Why did this happen? This did not happen when we did same type of deployments earlier. How can we prevent this from happening in the future.

    Read the article

  • Unable to record using Jmeter: [help me very urgent]

    - by krish
    Hi, I am trying to record a http web page using Jmeter 2.3.3 version.I has setup the JMeter proxy and tried, but did n't work. I have followed the below steps. 1. Launch jmeter 2.3.3, added thred group to test plan 2. Under Workbench-add-non-test elements- added HTTP proxy server. proxy server setting are port:9090, target:use recording controller, grouping:donot group samplers, Type:HTTp request and checked the boxes of all under http sampler settings 3.Saved the settings 4. Now in browser(IE 7.0 or firefox 3.0.16), under connection settings, setup the manual proxy settings as local host and port as 9090(no auto detect settings nothing, only manual proxy). Setting saved 5.Now in the jmeter, started the http proxy server. 6. Open a browser and hit the webpage needs to be tested. The page is not opened. In fact because of the changes made in browsers, no pages are opened. Whenever i try hitting a page, the pages are recorded in the Jmeter. but without the page open, how can i test. I looking for an immediate answer and my work is blocked. Immediate answer would be appreciated.

    Read the article

  • Stop the constant random reboots of my GIGABYTE GA-B75M-D3V

    - by Frederic
    I've got some issues with a new system. It's rebooting constantly. The system consists of a: brand new: Gigabyte GA-B75M-D3V with F9 BIOS (latest) Intel Core i5-3470 Ivy Bridge 2x 8GB G.SKILL Ripjaws 1600MHz memory (mem-tested x-86) coming from a stable system: Creative Soundcard X-FI Titanium Asus Radeon HD4850 OCZ Vertex 3 120G SSD Sata 3 Hard disk 1TB Sata 2 ASUS Blu-ray Drive PSU 400w Connected peripherals : Toshiba tv (displayport on dvi of MB or HD4850) Wired mouse, wireless keyboard (logitech) Bluetooth usb key Azio main problem : it's not possible to read the errors from the MB. nothing on the manual neither on internet. At the beginning, I received a MB with graphic problems and the problem of rebooting. I RMA'd it. The new one doesn't have any graphic problems. but it's still constantly rebooting. I removed everything except the HD, the sound-card, the blu-ray drive and the wireless keyboard. It's still unexpectdly rebooting. I'm running a test with just the motherboard and the HD. I will update this text after the test. I've got some questions : Somebody have an idea of a test? The PSU could cause that problem? I used it a lot of years with the stable system. Update 1: BTW, if anyone has the same problem, the manual won't say it but you'll need to reset the bios between two tests (the screwdriver on the two pins) if you suspect a problem of compatibility .

    Read the article

  • How to remove static IP from Mitel 5312 and enable DHCP

    - by jimbo
    I'm not sure this is the right forum for this question -- although I'm confident I'll be told if not! -- but I've read the fine manual (at least, such a manual as I have), I've googled and I cannot get any insight into where to even start solving this problem. I have a bunch of Mitel 5312 handsets, talking to a 3300 ICP controller. Some handsets are at a remote location, get an address from my DHCP server over there, and use the Mitel "Teleworker" extension to connect in over the Internet. The remaining handsets were set up with static IPs by a BT-supplied engineer, on the same subnet as the ICP itself. So far, so good. I have one remaining teleworker licence, and need to move a handset from the home location to the remote. I've managed to boot it and configure teleworker, but I cannot for the life of me see where I tell it to forget its static IP, and make a DHCP request. Any ideas? Should I be looking on the controller, or holding magic combinations of buttons on the handset itself? EDIT: Following some advice from Robert, below, I've broken out a spare device and reassigned the profile for this user's extension to the MAC of the new phone, and a new profile to the old MAC. Unfortunately this still doesn't get me anywhere -- the new handset now asks for the teleworker install password. I suspect I'm going to have to get a Mitel engineer involved here, since I've never been given that password... Unless anyone has any great ideas?

    Read the article