Search Results

Search found 27248 results on 1090 pages for 'table adapter'.

Page 190/1090 | < Previous Page | 186 187 188 189 190 191 192 193 194 195 196 197  | Next Page >

  • nf_conntrack complaints in dmesg

    - by Alexander Gladysh
    While investigating complains on bad HTTP server performance, I've discovered these lines in dmesg of my Xen XCP host that contains a guest OS with said server: [11458852.811070] net_ratelimit: 321 callbacks suppressed [11458852.811075] nf_conntrack: table full, dropping packet. [11458852.819957] nf_conntrack: table full, dropping packet. [11458852.821083] nf_conntrack: table full, dropping packet. [11458852.822195] nf_conntrack: table full, dropping packet. [11458852.824987] nf_conntrack: table full, dropping packet. [11458852.825298] nf_conntrack: table full, dropping packet. [11458852.825891] nf_conntrack: table full, dropping packet. [11458852.826225] nf_conntrack: table full, dropping packet. [11458852.826234] nf_conntrack: table full, dropping packet. [11458852.826814] nf_conntrack: table full, dropping packet. Complains are repeated every five seconds (number of suppressed callbacks is different each time). What can these sympthoms mean? Is that bad? Any hints? (Note that the question is more narrow than "how to solve specific case of bad HTTP server performance", so I do not give more details on that.) Additional info: $ uname -a Linux MYHOST 3.2.0-24-generic #37-Ubuntu SMP Wed Apr 25 08:43:22 UTC 2012 x86_64 x86_64 x86_64 GNU/Linux $ lsb_release -a No LSB modules are available. Distributor ID: Ubuntu Description: Ubuntu 12.04 LTS Release: 12.04 Codename: precise $ cat /proc/sys/net/netfilter/nf_conntrack_max 1548576 The server is under about 10M hits / day load.

    Read the article

  • Dual mode 802.11n PCI adapters

    - by Mike Thompson
    I have recently bought a DLink DIR-825 router. It is a dual mode (2.4GZ & 5GHZ) 802.11n wireless access point/router. What is a good PCI adapter to pair with it? DLink appear to only make one dual mode adapter, which is the DWA-160 USB adapter. They don't seem to have a PCI adapter in their range, which seems very strange. Do any of the other network manufacturers make a good dual mode adapter?

    Read the article

  • When importing an Access table into Excel, a look-up column is showing all values as numbers

    - by user3651997
    I have a basic Access to Excel question that has me frustrated. I have two Access 2010 data tables. One is a list of managers. The primary key is a manager ID (which is an autonumber because managers can have the same name), and each row also has manager name, manager email, etc. The second data table is a list of departments. The primary key for each row is a unique department code, and the foreign key is a manager ID (autonumber). I used the Look-up Wizard to create this connection. However, Access does not show the manager ID in the foreign key location. It shows Manager Name like I requested when I used the Look-up Wizard. Now I am trying to import the second table (departments) into Excel 2010. I clicked import from Access, chose the Department table, and everything popped into Excel. BUT, the Manager Name column is showing Manager ID instead. So I have a list of numbers instead of names. How can I make Excel show what I see in Access? Thanks!

    Read the article

  • Oracle OpenWorld 2013: First glimpses of the new SOA Suite 12c by Lucas Jellema

    - by JuergenKress
    During this week’s Oracle OpenWorld Conference, we were given some sneak peeks into the short term future of the Oracle SOA Suite. During various roadmap sessions, on the demo grounds as well as in the keynote session by Thomas Kurian (the replay of which you can see here, new features were described and demonstrated, allowing us to get a fairly good overview of what is going to come for SOA Suite - later in 2013 and sometime in 2014 (probably the first half of that year). The SOA Suite plays an important part in the three themes Thomas Kurian set down for the Fusion Middleware suite of products: support for mobility, cloud and business user empowerment. Some of the highlighted new aspects of Oracle SOA Suite are: Adapters to connect from on-premise to in-the-cloud – specifically targeting SalesForce, RightNow and also providing an SDK to create custom integrations into the cloud (the first cloud adapters will be released on 11g, before the end of the year) Mobile enablement by exposing RESTful services that communicate using JSON as well as adding the capability to call out to such services (12c functionality) Enhanced functionality on Exalogic (of course it runs faster on Exalogic, up to 20 times) Modular runtime with a lighter footprint. A brief demonstration of the Cloud Adapter was given by Demed L’Her during said keynote. The next screenshot shows the Adapter wizard for the Cloud Adapter. It allows the developer to pick a specific operation for a specific business object exposed by RightNow (or SalesForce) (the adapter knows about the APIs exposed by RightNow and SalesForce): This next screenshot shows the adapter that is used in SOA Suite 12c to expose a RESTful service on top of an SCA Composite or a Service Bus service: Read the full article here. SOA & BPM Partner Community For regular information on Oracle SOA Suite become a member in the SOA & BPM Partner Community for registration please visit www.oracle.com/goto/emea/soa (OPN account required) If you need support with your account please contact the Oracle Partner Business Center. Blog Twitter LinkedIn Facebook Wiki Mix Forum Technorati Tags: Amis,Lucas Jellema,SOA Suite 12c,SOA Community,Oracle SOA,Oracle BPM,Community,OPN,Jürgen Kress

    Read the article

  • Can I get sensible labels for lm-sensors output for "applesmc-isa-0300"?

    - by TK Kocheran
    2011 8,3 Macbook Pro running 64bit 11.10. When I run sensors from the lm-sensors package, I get a lot of information, but no way to understand it: coretemp-isa-0000 Adapter: ISA adapter Physical id 0: +53.0°C (high = +86.0°C, crit = +100.0°C) Core 0: +53.0°C (high = +86.0°C, crit = +100.0°C) Core 1: +52.0°C (high = +86.0°C, crit = +100.0°C) Core 2: +50.0°C (high = +86.0°C, crit = +100.0°C) Core 3: +49.0°C (high = +86.0°C, crit = +100.0°C) applesmc-isa-0300 Adapter: ISA adapter Left side : 2001 RPM (min = 2000 RPM) Right side : 2001 RPM (min = 2000 RPM) TB0T: +33.2°C TB1T: +33.2°C TB2T: +29.0°C TC0C: +52.8°C TC0D: +47.2°C TC0E: +51.8°C TC0F: +53.0°C TC0J: +1.0°C TC0P: +44.5°C TC1C: +52.0°C TC2C: +52.0°C TC3C: +52.0°C TC4C: +52.0°C TCFC: +0.2°C TCGC: +51.0°C TCSA: +52.0°C TCTD: +0.0°C TG0D: +44.5°C TG0P: +43.2°C THSP: +37.5°C TM0S: +57.5°C TMBS: +0.0°C TP0P: +50.0°C TPCD: +55.0°C The core temp info is really useful and I'm pretty sure that Left/Right Side refers to the two fans within, but otherwise, I have no idea what this information means. Is there something I can use to normalize this information?

    Read the article

  • Spooling in SQL execution plans

    - by Rob Farley
    Sewing has never been my thing. I barely even know the terminology, and when discussing this with American friends, I even found out that half the words that Americans use are different to the words that English and Australian people use. That said – let’s talk about spools! In particular, the Spool operators that you find in some SQL execution plans. This post is for T-SQL Tuesday, hosted this month by me! I’ve chosen to write about spools because they seem to get a bad rap (even in my song I used the line “There’s spooling from a CTE, they’ve got recursion needlessly”). I figured it was worth covering some of what spools are about, and hopefully explain why they are remarkably necessary, and generally very useful. If you have a look at the Books Online page about Plan Operators, at http://msdn.microsoft.com/en-us/library/ms191158.aspx, and do a search for the word ‘spool’, you’ll notice it says there are 46 matches. 46! Yeah, that’s what I thought too... Spooling is mentioned in several operators: Eager Spool, Lazy Spool, Index Spool (sometimes called a Nonclustered Index Spool), Row Count Spool, Spool, Table Spool, and Window Spool (oh, and Cache, which is a special kind of spool for a single row, but as it isn’t used in SQL 2012, I won’t describe it any further here). Spool, Table Spool, Index Spool, Window Spool and Row Count Spool are all physical operators, whereas Eager Spool and Lazy Spool are logical operators, describing the way that the other spools work. For example, you might see a Table Spool which is either Eager or Lazy. A Window Spool can actually act as both, as I’ll mention in a moment. In sewing, cotton is put onto a spool to make it more useful. You might buy it in bulk on a cone, but if you’re going to be using a sewing machine, then you quite probably want to have it on a spool or bobbin, which allows it to be used in a more effective way. This is the picture that I want you to think about in relation to your data. I’m sure you use spools every time you use your sewing machine. I know I do. I can’t think of a time when I’ve got out my sewing machine to do some sewing and haven’t used a spool. However, I often run SQL queries that don’t use spools. You see, the data that is consumed by my query is typically in a useful state without a spool. It’s like I can just sew with my cotton despite it not being on a spool! Many of my favourite features in T-SQL do like to use spools though. This looks like a very similar query to before, but includes an OVER clause to return a column telling me the number of rows in my data set. I’ll describe what’s going on in a few paragraphs’ time. So what does a Spool operator actually do? The spool operator consumes a set of data, and stores it in a temporary structure, in the tempdb database. This structure is typically either a Table (ie, a heap), or an Index (ie, a b-tree). If no data is actually needed from it, then it could also be a Row Count spool, which only stores the number of rows that the spool operator consumes. A Window Spool is another option if the data being consumed is tightly linked to windows of data, such as when the ROWS/RANGE clause of the OVER clause is being used. You could maybe think about the type of spool being like whether the cotton is going onto a small bobbin to fit in the base of the sewing machine, or whether it’s a larger spool for the top. A Table or Index Spool is either Eager or Lazy in nature. Eager and Lazy are Logical operators, which talk more about the behaviour, rather than the physical operation. If I’m sewing, I can either be all enthusiastic and get all my cotton onto the spool before I start, or I can do it as I need it. “Lazy” might not the be the best word to describe a person – in the SQL world it describes the idea of either fetching all the rows to build up the whole spool when the operator is called (Eager), or populating the spool only as it’s needed (Lazy). Window Spools are both physical and logical. They’re eager on a per-window basis, but lazy between windows. And when is it needed? The way I see it, spools are needed for two reasons. 1 – When data is going to be needed AGAIN. 2 – When data needs to be kept away from the original source. If you’re someone that writes long stored procedures, you are probably quite aware of the second scenario. I see plenty of stored procedures being written this way – where the query writer populates a temporary table, so that they can make updates to it without risking the original table. SQL does this too. Imagine I’m updating my contact list, and some of my changes move data to later in the book. If I’m not careful, I might update the same row a second time (or even enter an infinite loop, updating it over and over). A spool can make sure that I don’t, by using a copy of the data. This problem is known as the Halloween Effect (not because it’s spooky, but because it was discovered in late October one year). As I’m sure you can imagine, the kind of spool you’d need to protect against the Halloween Effect would be eager, because if you’re only handling one row at a time, then you’re not providing the protection... An eager spool will block the flow of data, waiting until it has fetched all the data before serving it up to the operator that called it. In the query below I’m forcing the Query Optimizer to use an index which would be upset if the Name column values got changed, and we see that before any data is fetched, a spool is created to load the data into. This doesn’t stop the index being maintained, but it does mean that the index is protected from the changes that are being done. There are plenty of times, though, when you need data repeatedly. Consider the query I put above. A simple join, but then counting the number of rows that came through. The way that this has executed (be it ideal or not), is to ask that a Table Spool be populated. That’s the Table Spool operator on the top row. That spool can produce the same set of rows repeatedly. This is the behaviour that we see in the bottom half of the plan. In the bottom half of the plan, we see that the a join is being done between the rows that are being sourced from the spool – one being aggregated and one not – producing the columns that we need for the query. Table v Index When considering whether to use a Table Spool or an Index Spool, the question that the Query Optimizer needs to answer is whether there is sufficient benefit to storing the data in a b-tree. The idea of having data in indexes is great, but of course there is a cost to maintaining them. Here we’re creating a temporary structure for data, and there is a cost associated with populating each row into its correct position according to a b-tree, as opposed to simply adding it to the end of the list of rows in a heap. Using a b-tree could even result in page-splits as the b-tree is populated, so there had better be a reason to use that kind of structure. That all depends on how the data is going to be used in other parts of the plan. If you’ve ever thought that you could use a temporary index for a particular query, well this is it – and the Query Optimizer can do that if it thinks it’s worthwhile. It’s worth noting that just because a Spool is populated using an Index Spool, it can still be fetched using a Table Spool. The details about whether or not a Spool used as a source shows as a Table Spool or an Index Spool is more about whether a Seek predicate is used, rather than on the underlying structure. Recursive CTE I’ve already shown you an example of spooling when the OVER clause is used. You might see them being used whenever you have data that is needed multiple times, and CTEs are quite common here. With the definition of a set of data described in a CTE, if the query writer is leveraging this by referring to the CTE multiple times, and there’s no simplification to be leveraged, a spool could theoretically be used to avoid reapplying the CTE’s logic. Annoyingly, this doesn’t happen. Consider this query, which really looks like it’s using the same data twice. I’m creating a set of data (which is completely deterministic, by the way), and then joining it back to itself. There seems to be no reason why it shouldn’t use a spool for the set described by the CTE, but it doesn’t. On the other hand, if we don’t pull as many columns back, we might see a very different plan. You see, CTEs, like all sub-queries, are simplified out to figure out the best way of executing the whole query. My example is somewhat contrived, and although there are plenty of cases when it’s nice to give the Query Optimizer hints about how to execute queries, it usually doesn’t do a bad job, even without spooling (and you can always use a temporary table). When recursion is used, though, spooling should be expected. Consider what we’re asking for in a recursive CTE. We’re telling the system to construct a set of data using an initial query, and then use set as a source for another query, piping this back into the same set and back around. It’s very much a spool. The analogy of cotton is long gone here, as the idea of having a continual loop of cotton feeding onto a spool and off again doesn’t quite fit, but that’s what we have here. Data is being fed onto the spool, and getting pulled out a second time when the spool is used as a source. (This query is running on AdventureWorks, which has a ManagerID column in HumanResources.Employee, not AdventureWorks2012) The Index Spool operator is sucking rows into it – lazily. It has to be lazy, because at the start, there’s only one row to be had. However, as rows get populated onto the spool, the Table Spool operator on the right can return rows when asked, ending up with more rows (potentially) getting back onto the spool, ready for the next round. (The Assert operator is merely checking to see if we’ve reached the MAXRECURSION point – it vanishes if you use OPTION (MAXRECURSION 0), which you can try yourself if you like). Spools are useful. Don’t lose sight of that. Every time you use temporary tables or table variables in a stored procedure, you’re essentially doing the same – don’t get upset at the Query Optimizer for doing so, even if you think the spool looks like an expensive part of the query. I hope you’re enjoying this T-SQL Tuesday. Why not head over to my post that is hosting it this month to read about some other plan operators? At some point I’ll write a summary post – once I have you should find a comment below pointing at it. @rob_farley

    Read the article

  • How to filter a mysql database with user input on a website and then spit the filtered table back to the website? [migrated]

    - by Luke
    I've been researching this on google for literally 3 weeks, racking my brain and still not quite finding anything. I can't believe this is so elusive. (I'm a complete beginner so if my terminology sounds stupid then that's why.) I have a database in mysql/phpmyadmin on my web host. I'm trying to create a front end that will allow a user to specify criteria for querying the database in a way that they don't have to know sql, basically just combo boxes and checkboxes on a form. Then have this form 'submit' a query to the database, and show the filtered tables. This is how the SQL looks in Microsoft Access: PARAMETERS TEXTINPUT1 Text ( 255 ), NUMBERINPUT1 IEEEDouble; // pops up a list of parameters for the user to input SELECT DISTINCT Table1.Column1, Table1.Column2, Table1.Column3,* // selects only the unique rows in these three columns FROM Table1 // the table where this query is happening WHERE (((Table1.Column1) Like TEXTINPUT1] AND ((Table1.Column2)<=[NUMBERINPUT1] AND ((Table1.Column3)>=[NUMBERINPUT1])); // the criteria for the filter, it's comparing the user input parameters to the data in the rows and only selecting matches according to the equal sign, or greater than + equal sign, or less than + equal sign What I don't get: WHAT IN THE WORLD AM I SUPPOSED TO USE (that isn't totally hard)!? I've tried google fusion tables - doesn't filter right with numerical data or empty cells in rows, can't relate tables I've tried DataTables.net, can't filter right with numerical data and can't use SQL without a bunch of indepth knowledge, not even sure it can if you have that.. I've looked into using jQuery with google spreadsheets, doesn't work at all either I have no idea how I'm supposed to build a front end with my database. Every place that looks promising (like zohocreator) is asking for money, and is far too simplified to be able to do the LIKE criteria or SELECT DISTINCT stuff.

    Read the article

  • ArchBeat Link-o-Rama for November 30, 2012

    - by Bob Rhubart
    Oracle SOA Database Adapter Polling in a Cluster: A Handy Logical Delete Pattern | Carlo Arteaga "Using the SOA database adapter usually becomes easier when the adapter is simply viewed and treated as a gateway between the Oracle SOA composite world and the database world," says Carlo Arteaga. "When viewing the adapter in this light one should come to understand that the adapter is not the ultimate all-in-one solution for database access and database logic needs." OIM 11g : Multi-thread approach for writing custom scheduled job | Saravanan V S Saravanan shares insight and expertise relevant to "designing and developing an OIM schedule job that uses multi threaded approach for updating data in OIM using APIs." When Premature Optimization Isn't | Dustin Marx "Perhaps the most common situations in which I have seen developers make bad decisions under the pretense of 'avoiding premature optimization' is making bad architecture or design choices," says Dustin Marx. Protecting Intranet and Extranet Applications with a Single OAM 11g Deployment | Brian Eidelman Oracle Fusion Middleware A-Team member Brian Eideleman's post, part of the Oracle Access Manager Academy series, explores issues and soluions around setting up a single OAM deployment to protect both intranet and extranet apps. Thought for the Day "Never make a technical decision based upon the politics of the situation, and never make a political decision based upon technical issues." — Geoffrey James Source: SoftwareQuotes.com

    Read the article

  • LM Sensors always returning same (invalid) value for one temp sensor

    - by pkaeding
    I am trying to monitor the temp sensors on a server, and plot them using Cacti. I have lm-sensors installed and working correctly. For example, here is the output from sensors: % sensors acpitz-virtual-0 Adapter: Virtual device temp1: +26.8 C (crit = +100.0 C) temp2: +32.0 C (crit = +60.0 C) coretemp-isa-0000 Adapter: ISA adapter Core 0: +36.0 C (high = +105.0 C, crit = +105.0 C) coretemp-isa-0001 Adapter: ISA adapter Core 1: +42.0 C (high = +105.0 C, crit = +105.0 C) However, when I try to get this data via SNMP, I get only one sensor's temperature correctly, and another one always returns 100.000 C: % snmpwalk -Os -c public -v 1 10.8.0.18 -m ALL lmTempSensors lmTempSensorsIndex.1 = INTEGER: 0 lmTempSensorsIndex.2 = INTEGER: 1 lmTempSensorsDevice.1 = STRING: temp1 lmTempSensorsDevice.2 = STRING: temp1 lmTempSensorsValue.1 = Gauge32: 26800 lmTempSensorsValue.2 = Gauge32: 100000 So, my question is two-fold: Why is the second sensor that is returned by SNMP giving a value of 100 C (when it should be 32 C) Why are my CPU core sensors not being returned by SNMP?

    Read the article

  • How to apply patches or upgrade BAM 11g

    - by anirudh.pucha(at)oracle.com
    In general, before upgrading to latest patchset or applying any BAM adapter patches, always make sure the BAM Adapter staging-mode is set to "nostage". This configuration can be verified by searching "OracleBamAdapter" key word in MiddlewareHome/user_projects/domains//config/config.xml file.To redeploy bam adapter, you should pick "I will make the deployment accessible from the following location" as the "Source accessibility" option and set the path to point to /Oracle_SOA1/soa/connectors/OracleBamAdapter.rar, otherwise, the staging-mode will be unset

    Read the article

  • How to stop fan running always on Asus P8P76LE motherboard with ATI Radeon HD6900

    - by Chris Good
    I'm using Ubuntu 12.04 LTS. I'm not sure if it is the CPU (i7) fan or the video card fan. I've tried using lm-sensors & fancontrol sudo sensors-detect Now follows a summary of the probes I have just done. Just press ENTER to continue: Driver `w83627ehf': * ISA bus, address 0x290 Chip `Nuvoton NCT6776F Super IO Sensors' (confidence: 9) Driver `coretemp': * Chip `Intel digital thermal sensor' (confidence: 9) To load everything that is needed, add this to /etc/modules: # Chip drivers coretemp w83627ehf Like many people, I'm also getting error: /usr/sbin/pwmconfig: There are no pwm-capable sensor modules installed Here is the output of sensors: # sensors radeon-pci-0100 Adapter: PCI adapter temp1: +71.0°C coretemp-isa-0000 Adapter: ISA adapter Physical id 0: +44.0°C (high = +80.0°C, crit = +98.0°C) Core 0: +44.0°C (high = +80.0°C, crit = +98.0°C) Core 1: +40.0°C (high = +80.0°C, crit = +98.0°C) Core 2: +43.0°C (high = +80.0°C, crit = +98.0°C) Core 3: +42.0°C (high = +80.0°C, crit = +98.0°C) I'm hoping some-one has already solved this for my configuration because this seems to be a problem for many people and there are many different suggestions.

    Read the article

  • Organising data access for dependency injection

    - by IanAWP
    In our company we have a relatively long history of database backed applications, but have only just begun experimenting with dependency injection. I am looking for advice about how to convert our existing data access pattern into one more suited for dependency injection. Some specific questions: Do you create one access object per table (Given that a table represents an entity collection)? One interface per table? All of these would need the low level Data Access object to be injected, right? What about if there are dozens of tables, wouldn't that make the composition root into a nightmare? Would you instead have a single interface that defines things like GetCustomer(), GetOrder(), etc? If I took the example of EntityFramework, then I would have one Container that exposes an object for each table, but that container doesn't conform to any interface itself, so doesn't seem like it's compatible with DI. What we do now, in case it helps: The way we normally manage data access is through a generic data layer which exposes CRUD/Transaction capabilities and has provider specific subclasses which handle the creation of IDbConnection, IDbCommand, etc. Actual table access uses Table classes that perform the CRUD operations associated with a particular table and accept/return domain objects that the rest of the system deals with. These table classes expose only static methods, and utilise a static DataAccess singleton instantiated from a config file.

    Read the article

  • how to link a c++ object to a local variable in Lua

    - by MahanGM
    I'm completing my scripting interface with Lua, but recently I've stuck at some point. I have several functions for my Entitiy events like Update(). I have a function called create_entitiy() which instantiate a new entity from a given entity index: function Update() local bullet = create_entity(0, 0, "obj_bullet") end create_entity returns a table which is the properties of the created entity. Now how can I make a connection between bullet variable and my newly created object? Right now for previously added objects to the scene, I simply set a global table for each of them and then after every call to Update(), I go through registered names to find object tables and perform new changes. Like the one below: function Update() if keyboard_key_press(vk_right) then obj_player.x += 3 end I can get obj_player table because I know its name from C++, plus I can get it as a global table and simply reach for the first instance named obj_player. Is there any solution for me to make bullet variable act like this? I was thinking to get all local variables in Update() function and check for every one to see if is it table and it has an unique field attached to it like id, this way I can determine that this is an object table and do the rest of the process. By the way, is this interface going to work easier with luaBind if I implement it? Bottom line: How can I make a local variable in Lua that receives a table from create_entity function and track that local variable to capture it from C++. e. g. function Update() local bullet = create_entity(0, 0, "obj_bullet") bullet.x = 10 <== Commit a change in table end Now I want to get variable bullet from C++. And it's not just this variable, there might be a ton of these local variables with different names.

    Read the article

  • Given a database table where multiple rows have the same values and only the most recent record is to be returned

    - by Jim Lahman
    I have a table where there are multiple records with the same value but varying creation dates.  A sample of the database columns is shown here:   1: select lot_num, to_char(creation_dts,'DD-MON-YYYY HH24:MI:SS') as creation_date 2: from coil_setup 3: order by lot_num   LOT_NUM                        CREATION_DATE        ------------------------------ -------------------- 1435718.002                    24-NOV-2010 11:45:54 1440026.002                    17-NOV-2010 06:50:16 1440026.002                    08-NOV-2010 23:28:24 1526564.002                    01-DEC-2010 13:14:04 1526564.002                    08-NOV-2010 22:39:01 1526564.002                    01-NOV-2010 17:04:30 1605920.003                    29-DEC-2010 10:01:24 1945352.003                    14-DEC-2010 01:50:37 1945352.003                    09-DEC-2010 04:44:22 1952718.002                    25-OCT-2010 09:33:19 1953866.002                    20-OCT-2010 18:38:31 1953866.002                    18-OCT-2010 16:15:25   Notice that there are multiple instances of of the same lot number as shown in bold. To only return the most recent instance, issue this SQL statement: 1: select lot_num, to_char(creation_date,'DD-MON-YYYY HH24:MI:SS') as creation_date 2: from 3: ( 4: select rownum r, lot_num, max(creation_dts) as creation_date 5: from coil_setup group by rownum, lot_num 6: order by lot_num 7: ) 8: where r < 100  LOT_NUM                        CREATION_DATE        ------------------------------ -------------------- 2019416.002                    01-JUL-2010 00:01:24 2022336.003                    06-OCT-2010 15:25:01 2067230.002                    01-JUL-2010 00:36:48 2093114.003                    02-JUL-2010 20:10:51 2093982.002                    02-JUL-2010 14:46:11 2093984.002                    02-JUL-2010 14:43:18 2094466.003                    02-JUL-2010 20:04:48 2101074.003                    11-JUL-2010 09:02:16 2103746.002                    02-JUL-2010 15:07:48 2103758.003                    11-JUL-2010 09:02:13 2104636.002                    02-JUL-2010 15:11:25 2106688.003                    02-JUL-2010 13:55:27 2106882.003                    02-JUL-2010 13:48:47 2107258.002                    02-JUL-2010 12:59:48 2109372.003                    02-JUL-2010 20:49:12 2110182.003                    02-JUL-2010 19:59:19 2110184.003                    02-JUL-2010 20:01:03

    Read the article

  • How to stop fan running always on Asus P8P67LE motherboard with ATI Radeon HD6900

    - by Chris Good
    I'm using Ubuntu 12.04 LTS. I'm not sure if it is the CPU (i7) fan or the video card fan. I've tried using lm-sensors & fancontrol sudo sensors-detect Now follows a summary of the probes I have just done. Just press ENTER to continue: Driver `w83627ehf': * ISA bus, address 0x290 Chip `Nuvoton NCT6776F Super IO Sensors' (confidence: 9) Driver `coretemp': * Chip `Intel digital thermal sensor' (confidence: 9) To load everything that is needed, add this to /etc/modules: # Chip drivers coretemp w83627ehf Like many people, I'm also getting error: /usr/sbin/pwmconfig: There are no pwm-capable sensor modules installed Here is the output of sensors: # sensors radeon-pci-0100 Adapter: PCI adapter temp1: +71.0°C coretemp-isa-0000 Adapter: ISA adapter Physical id 0: +44.0°C (high = +80.0°C, crit = +98.0°C) Core 0: +44.0°C (high = +80.0°C, crit = +98.0°C) Core 1: +40.0°C (high = +80.0°C, crit = +98.0°C) Core 2: +43.0°C (high = +80.0°C, crit = +98.0°C) Core 3: +42.0°C (high = +80.0°C, crit = +98.0°C) I'm hoping some-one has already solved this for my configuration because this seems to be a problem for many people and there are many different suggestions.

    Read the article

  • Why does calling CreateDXGIFactory prevent my program from exiting?

    - by smoth190
    I'm using CreateDXGIFactory to get the graphics adapters and display modes. When I call it, it works fine and I get all the data. However, when I exit my program, the main Win32 thread exits, but something stays open because it keeps debugging. Does CreateDXGIFactory create an extra thread and I'm not closing it? I don't understand. The only thing I would suspect is that in the documentation it says it doesn't work if it's called from DllMain. It is in a DLL, but it's not called from DllMain. And it doesn't fail, either. I'm using DirectX 11. Here is the function that initializes DirectX. I haven't gotten past retrieving the refresh rate because of this problem. I commented everything out to pinpoint the problem. bool CGraphicsManager::InitDirectX(HWND hWnd, int width, int height) { HRESULT result; IDXGIFactory* factory; IDXGIOutput* output; IDXGIAdapter* adapter; DXGI_MODE_DESC* displayModes; DXGI_ADAPTER_DESC adapterDesc; unsigned int modeCount = 0; unsigned int refreshNum = 0; unsigned int refreshDen = 0; //First, we need to get the monitors refresh rater result = CreateDXGIFactory(__uuidof(IDXGIFactory), (void**)&factory); //if(FAILED(result)) //{ //MemoryUtil::MessageBoxError(TEXT("InitDirectX"), 0, 0, TEXT("Failed to create DXGI factory\nError:\n%s"), DXGetErrorDescription(result)); //return false; //} /*//Create a graphics card adapter result = factory->EnumAdapters(0, &adapter); if(FAILED(result)) { MemoryUtil::MessageBoxError(TEXT("InitDirectX"), 0, 0, TEXT("Failed to get graphics adapters\nError:\n%s"), DXGetErrorDescription(result)); return false; } //Get the output result = adapter->EnumOutputs(0, &output); if(FAILED(result)) { MemoryUtil::MessageBoxError(TEXT("InitDirectX"), 0, 0, TEXT("Failed to get adapter output\nError:\n%s"), DXGetErrorDescription(result)); return false; } //Get the modes result = output->GetDisplayModeList(DXGI_FORMAT_R8G8B8A8_UNORM, DXGI_ENUM_MODES_INTERLACED, &modeCount, 0); if(FAILED(result)) { MemoryUtil::MessageBoxError(TEXT("InitDirectX"), 0, 0, TEXT("Failed to get mode count\nError:\n%s"), DXGetErrorDescription(result)); return false; } displayModes = new DXGI_MODE_DESC[modeCount]; result = output->GetDisplayModeList(DXGI_FORMAT_R8G8B8A8_UNORM, DXGI_ENUM_MODES_INTERLACED, &modeCount, displayModes); if(FAILED(result)) { MemoryUtil::MessageBoxError(TEXT("InitDirectX"), 0, 0, TEXT("Failed to get display modes\nError:\n%s"), DXGetErrorDescription(result)); return false; } //Now we need to find one for our screen size for(unsigned int i = 0; i < modeCount; i++) { if(displayModes[i].Width == (unsigned int)width) { if(displayModes[i].Height == (unsigned int)height) { refreshNum = displayModes[i].RefreshRate.Numerator; refreshDen = displayModes[i].RefreshRate.Denominator; break; } } } //Store the video card data result = adapter->GetDesc(&adapterDesc); if(FAILED(result)) { MemoryUtil::MessageBoxError(TEXT("InitDirectX"), 0, 0, TEXT("Failed to get adapter description\nError:\n%s"), DXGetErrorDescription(result)); return false; } m_videoCard = new CVideoCard(); MemoryUtil::CreateGameObject(m_videoCard); m_videoCard->VideoCardMemory = (unsigned int)(adapterDesc.DedicatedVideoMemory); wcstombs_s(0, m_videoCard->VideoCardDescription, 128, adapterDesc.Description, 128);*/ //ReleaseCOM(output); //ReleaseCOM(adapter); ReleaseCOM(factory); //DeletePointerArray(displayModes); return true; } Also, I don't know if this means anything, but this is some of the output log when the function is commented out: //... 'LostRock.exe': Loaded 'C:\Windows\SysWOW64\msvcr100d.dll', Symbols loaded. 'LostRock.exe': Loaded 'C:\Windows\SysWOW64\imm32.dll', Cannot find or open the PDB file 'LostRock.exe': Loaded 'C:\Windows\SysWOW64\msctf.dll', Cannot find or open the PDB file 'LostRock.exe': Loaded 'C:\Windows\SysWOW64\uxtheme.dll', Cannot find or open the PDB file 'LostRock.exe': Loaded 'C:\Program Files (x86)\Common Files\microsoft shared\ink\tiptsf.dll', Cannot find or open the PDB file 'LostRock.exe': Loaded 'C:\Windows\SysWOW64\ole32.dll', Cannot find or open the PDB file 'LostRock.exe': Loaded 'C:\Windows\SysWOW64\oleaut32.dll', Cannot find or open the PDB file 'LostRock.exe': Loaded 'C:\Windows\SysWOW64\clbcatq.dll', Cannot find or open the PDB file 'LostRock.exe': Loaded 'C:\Windows\SysWOW64\oleacc.dll', Cannot find or open the PDB file The program '[6560] LostRock.exe: Native' has exited with code 0 (0x0). And when it isn't commented out... //... 'LostRock.exe': Loaded 'C:\Windows\SysWOW64\cfgmgr32.dll', Cannot find or open the PDB file 'LostRock.exe': Loaded 'C:\Windows\SysWOW64\devobj.dll', Cannot find or open the PDB file 'LostRock.exe': Loaded 'C:\Windows\SysWOW64\wintrust.dll', Cannot find or open the PDB file 'LostRock.exe': Loaded 'C:\Windows\SysWOW64\crypt32.dll', Cannot find or open the PDB file 'LostRock.exe': Loaded 'C:\Windows\SysWOW64\msasn1.dll', Cannot find or open the PDB file 'LostRock.exe': Unloaded 'C:\Windows\SysWOW64\setupapi.dll' 'LostRock.exe': Unloaded 'C:\Windows\SysWOW64\devobj.dll' 'LostRock.exe': Unloaded 'C:\Windows\SysWOW64\cfgmgr32.dll' 'LostRock.exe': Loaded 'C:\Windows\SysWOW64\clbcatq.dll', Cannot find or open the PDB file 'LostRock.exe': Loaded 'C:\Windows\SysWOW64\oleacc.dll', Cannot find or open the PDB file The thread 'Win32 Thread' (0xb94) has exited with code 0 (0x0). The program '[8096] LostRock.exe: Native' has exited with code 0 (0x0). //This is called when I click "Stop Debugging" P.S. I know it is CreateDXGIFactory because if I comment it out, the program exits correctly.

    Read the article

  • Giant battery consumption with dual graphics solution (only i-gpu working)

    - by Noel
    I use a Laptop with Intel Core i7 SandyBridge and integrated Intel HD3000 graphics as well as a Nvidia Geforce GTS 555M. So far, I got the impression my Laptop was running with the Nvidia graphics adapter only because the fan was always running on highest speed (and loudest noise) and it was getting very hot even when doing nothing. Also the battery is empty after ~40-50 minutes (while having ~4-5 hours with Intel graphics in Win7). Since this can't be healthy I wanted to switch to the integrated graphics instead. I was fairly surprised when the System Information showed me that the as graphics adapter I use "Intel M". Why is my battery empty so fast with Ubuntu? Without using the NVIDIA graphics adapter? Summary: I DONT WANT to use the Nvidia graphics adapter (OPTIMUS), I just want the Intel solution. As I have understood, the Intel solution is running already, emptying my battery 10x as fast as Win7. What is wrong? Any ideas?

    Read the article

  • Checking for DBNull

    - by Jim Lahman
    Using a table adapter to a SQL Server database table that returns a NULL record.  We determine the fields are NULL by comparing against System.DBNull Looking the NULL records in SQL Management studio   Using a table adapter to retrieve a record   1: try 2: { 3: this.vTrackingTableAdapter.FillByTrkZone(this.dsL1Write.vTracking, iTrkZone); 4: } 5: catch (Exception ex) 6: { 7: sLogMessage = String 8: .Format("Error getting coil number from tracking table at {0} - {1}", 9: sTrkName, 10: ex.Message); 11: throw new CannotReadTrackingTableException(sLogMessage); 12: }   Looking at the record as it returned from the table adapter:   ItemArrayObject Column [0] ChargeCoilNumber [1] HeadWeldZone [2] TailWeldZone [3] ZoneLen [4] ZoneCoilLen [5] Confirmed [6] Validated [7] EntryWidth [8] EntryThickness   Since each item in the ItemArray is an object, we can test for null   1: if (dsL1Write.vTracking.Rows[0].ItemArray[0] == System.DBNull.Value) 2: { 3: throw new NoCoilAtPORException("NULL coil found at tracking zone " + sTrkName); 4: }   If no records were returned by the table adapter 1: if (dsL1Write.vTracking.Rows.Count == 0) 2: { 3: throw new NoCoilAtPORException("No coils found at tracking zone " + sTrkName); 4: }

    Read the article

  • Reference Data Management

    - by rahulkamath
    Normal 0 false false false EN-US X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} table.MsoTableColorfulListAccent2 {mso-style-name:"Colorful List - Accent 2"; mso-tstyle-rowband-size:1; mso-tstyle-colband-size:1; mso-style-priority:72; mso-style-unhide:no; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-tstyle-shading:#F8EDED; mso-tstyle-shading-themecolor:accent2; mso-tstyle-shading-themetint:25; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Calibri","sans-serif"; color:black; mso-themecolor:text1;} table.MsoTableColorfulListAccent2FirstRow {mso-style-name:"Colorful List - Accent 2"; mso-table-condition:first-row; mso-style-priority:72; mso-style-unhide:no; mso-tstyle-shading:#9E3A38; mso-tstyle-shading-themecolor:accent2; mso-tstyle-shading-themeshade:204; mso-tstyle-border-bottom:1.5pt solid white; mso-tstyle-border-bottom-themecolor:background1; color:white; mso-themecolor:background1; mso-ansi-font-weight:bold; mso-bidi-font-weight:bold;} table.MsoTableColorfulListAccent2LastRow {mso-style-name:"Colorful List - Accent 2"; mso-table-condition:last-row; mso-style-priority:72; mso-style-unhide:no; mso-tstyle-shading:white; mso-tstyle-shading-themecolor:background1; mso-tstyle-border-top:1.5pt solid black; mso-tstyle-border-top-themecolor:text1; color:#9E3A38; mso-themecolor:accent2; mso-themeshade:204; mso-ansi-font-weight:bold; mso-bidi-font-weight:bold;} table.MsoTableColorfulListAccent2FirstCol {mso-style-name:"Colorful List - Accent 2"; mso-table-condition:first-column; mso-style-priority:72; mso-style-unhide:no; mso-ansi-font-weight:bold; mso-bidi-font-weight:bold;} table.MsoTableColorfulListAccent2LastCol {mso-style-name:"Colorful List - Accent 2"; mso-table-condition:last-column; mso-style-priority:72; mso-style-unhide:no; mso-ansi-font-weight:bold; mso-bidi-font-weight:bold;} table.MsoTableColorfulListAccent2OddColumn {mso-style-name:"Colorful List - Accent 2"; mso-table-condition:odd-column; mso-style-priority:72; mso-style-unhide:no; mso-tstyle-shading:#EFD3D2; mso-tstyle-shading-themecolor:accent2; mso-tstyle-shading-themetint:63; mso-tstyle-border-top:cell-none; mso-tstyle-border-left:cell-none; mso-tstyle-border-bottom:cell-none; mso-tstyle-border-right:cell-none; mso-tstyle-border-insideh:cell-none; mso-tstyle-border-insidev:cell-none;} table.MsoTableColorfulListAccent2OddRow {mso-style-name:"Colorful List - Accent 2"; mso-table-condition:odd-row; mso-style-priority:72; mso-style-unhide:no; mso-tstyle-shading:#F2DBDB; mso-tstyle-shading-themecolor:accent2; mso-tstyle-shading-themetint:51;} Reference Data Management Oracle Data Relationship Management (DRM) has always been extremely powerful as an Enterprise MDM solution that can help manage changes to master data in a way that influences enterprise structure, whether it be mastering chart of accounts to enable financial transformation, or revamping organization structures to drive business transformation and operational efficiencies, or mastering sales territories in light of rapid fire acquisitions that require frequent sales territory refinement, equitable distribution of leads and accounts to salespersons, and alignment of budget/forecast with results to optimize sales coverage. Increasingly, DRM is also being utilized by Oracle customers for reference data management, an emerging solution space that deserves some explanation. What is reference data? Reference data is a close cousin of master data. While master data may be more rapidly changing, requires consensus building across stakeholders and lends structure to business transactions, reference data is simpler, more slowly changing, but has semantic content that is used to categorize or group other information assets – including master data – and give them contextual value. The following table contains an illustrative list of examples of reference data by type. Reference data types may include types and codes, business taxonomies, complex relationships & cross-domain mappings or standards. Types & Codes Taxonomies Relationships / Mappings Standards Transaction Codes Industry Classification Categories and Codes, e.g., North America Industry Classification System (NAICS) Product / Segment; Product / Geo Calendars (e.g., Gregorian, Fiscal, Manufacturing, Retail, ISO8601) Lookup Tables (e.g., Gender, Marital Status, etc.) Product Categories City à State à Postal Codes Currency Codes (e.g., ISO) Status Codes Sales Territories (e.g., Geo, Industry Verticals, Named Accounts, Federal/State/Local/Defense) Customer / Market Segment; Business Unit / Channel Country Codes (e.g., ISO 3166, UN) Role Codes Market Segments Country Codes / Currency Codes / Financial Accounts Date/Time, Time Zones (e.g., ISO 8601) Domain Values Universal Standard Products and Services Classification (UNSPSC), eCl@ss International Classification of Diseases (ICD) e.g., ICD9 à IC10 mappings Tax Rates Why manage reference data? Reference data carries contextual value and meaning and therefore its use can drive business logic that helps execute a business process, create a desired application behavior or provide meaningful segmentation to analyze transaction data. Further, mapping reference data often requires human judgment. Sample Use Cases of Reference Data Management Healthcare: Diagnostic Codes The reference data challenges in the healthcare industry offer a case in point. Part of being HIPAA compliant requires medical practitioners to transition diagnosis codes from ICD-9 to ICD-10, a medical coding scheme used to classify diseases, signs and symptoms, causes, etc. The transition to ICD-10 has a significant impact on business processes, procedures, contracts, and IT systems. Since both code sets ICD-9 and ICD-10 offer diagnosis codes of very different levels of granularity, human judgment is required to map ICD-9 codes to ICD-10. The process requires collaboration and consensus building among stakeholders much in the same way as does master data management. Moreover, to build reports to understand utilization, frequency and quality of diagnoses, medical practitioners may need to “cross-walk” mappings -- either forward to ICD-10 or backwards to ICD-9 depending upon the reporting time horizon. Spend Management: Product, Service & Supplier Codes Similarly, as an enterprise looks to rationalize suppliers and leverage their spend, conforming supplier codes, as well as product and service codes requires supporting multiple classification schemes that may include industry standards (e.g., UNSPSC, eCl@ss) or enterprise taxonomies. Aberdeen Group estimates that 90% of companies rely on spreadsheets and manual reviews to aggregate, classify and analyze spend data, and that data management activities account for 12-15% of the sourcing cycle and consume 30-50% of a commodity manager’s time. Creating a common map across the extended enterprise to rationalize codes across procurement, accounts payable, general ledger, credit card, procurement card (P-card) as well as ACH and bank systems can cut sourcing costs, improve compliance, lower inventory stock, and free up talent to focus on value added tasks. Specialty Finance: Point of Sales Transaction Codes and Product Codes In the specialty finance industry, enterprises are confronted with usury laws – governed at the state and local level – that regulate financial product innovation as it relates to consumer loans, check cashing and pawn lending. To comply, it is important to demonstrate that transactions booked at the point of sale are posted against valid product codes that were on offer at the time of booking the sale. Since new products are being released at a steady stream, it is important to ensure timely and accurate mapping of point-of-sale transaction codes with the appropriate product and GL codes to comply with the changing regulations. Multi-National Companies: Industry Classification Schemes As companies grow and expand across geographies, a typical challenge they encounter with reference data represents reconciling various versions of industry classification schemes in use across nations. While the United States, Mexico and Canada conform to the North American Industry Classification System (NAICS) standard, European Union countries choose different variants of the NACE industry classification scheme. Multi-national companies must manage the individual national NACE schemes and reconcile the differences across countries. Enterprises must invest in a reference data change management application to address the challenge of distributing reference data changes to downstream applications and assess which applications were impacted by a given change.

    Read the article

  • OUCH! Laptop running SUPER HOT after 12.10 upgrade!

    - by dinkelk
    I was running 12.04 for 6 months, my laptop ran almost silently and cool enough to hold on my lap. I updated to 12.10 and now my computer gets too hot to hold on my lap and the fan is constantly running on full blast. This is the output of sensors: acpitz-virtual-0 Adapter: Virtual device temp1: +84.0°C (crit = +99.0°C) coretemp-isa-0000 Adapter: ISA adapter Physical id 0: +84.0°C (high = +86.0°C, crit = +100.0°C) Core 0: +74.0°C (high = +86.0°C, crit = +100.0°C) Core 1: +72.0°C (high = +86.0°C, crit = +100.0°C) Core 2: +75.0°C (high = +86.0°C, crit = +100.0°C) Core 3: +84.0°C (high = +86.0°C, crit = +100.0°C) radeon-pci-0100 Adapter: PCI adapter temp1: +76.0°C I have an HP Pavilion dv6, i7, amd radeon graphics. Please let me know if you need additional information. What could be different between the two Ubuntu editions that caused such a drastic change? Edit 1: Per @Paul's suggestion, I ran htop to try to narrow down the problem. Here is the result! (left side of terminal) (right side of terminal) This is about 10 minutes after boot-up, htop, yakuake, and a chrome page with 1 tab opened to this question are all that I have manually opened. The most taxing program to the CPU is htop itself. I think that the problem must lie elsewhere; my temps are already up to ~65C for the CPU and ~69C for the GPU, with nearly 0% CPU usage.

    Read the article

  • Laptop runs HOT after 12.10 upgrade!

    - by dinkelk
    I was running 12.04 for 6 months, my laptop ran almost silently and cool enough to hold on my lap. I updated to 12.10 and now my computer gets too hot to hold on my lap and the fan is constantly running on full blast. This is the output of sensors: acpitz-virtual-0 Adapter: Virtual device temp1: +84.0°C (crit = +99.0°C) coretemp-isa-0000 Adapter: ISA adapter Physical id 0: +84.0°C (high = +86.0°C, crit = +100.0°C) Core 0: +74.0°C (high = +86.0°C, crit = +100.0°C) Core 1: +72.0°C (high = +86.0°C, crit = +100.0°C) Core 2: +75.0°C (high = +86.0°C, crit = +100.0°C) Core 3: +84.0°C (high = +86.0°C, crit = +100.0°C) radeon-pci-0100 Adapter: PCI adapter temp1: +76.0°C I have an HP Pavilion dv6, i7, amd radeon graphics. Please let me know if you need additional information. What could be different between the two Ubuntu additions that caused such a drastic change? Edit 1: Per @Paul's suggestion, I ran htop to try to narrow down the problem. Here is the result! This is about 10 minutes after boot-up, htop, yakuake, and a chrome page with 1 tab opened to this question are all that I have manually opened. The most taxing program to the CPU is htop itself. I think that the problem must lie elsewhere; my temps are already up to ~65C for the CPU and ~69C for the GPU, with nearly 0% CPU usage.

    Read the article

  • aticonfig detects all graphics cards, but amdcccle shows the cards as disabled

    - by DevZer0
    I been having the strangest problem since few days ago. I have 3 ATI graphics cards and the aticonfig --list-adapter shows the following output * 0. 01:00.0 AMD Radeon HD 7900 Series 1. 02:00.0 AMD Radeon HD 7900 Series 2. 05:00.0 AMD Radeon HD 7900 Series when i do aticonfig --adapter=all --initial -f it generates the correct X config also. but after rebooting the output only show on primary monitor and when i look in amdcccle it shows the other 2 adapters as disabled. I tried with monitors attached and dummy plugs both but the situation doesn't change. Any idea whats causing this? also right clicking and making the adapter enabled in amdcccle and saving changes causes the X config to only have the adapter section and no screen section. after reboot the situation stays the same.

    Read the article

  • SQL Server 2005 Service Pack 3 won’t install.

    - by AngryHacker
    I am trying to install SQL Server 2005 Service Pack 3 and it keeps failing. Comes back with the following: Microsoft SQL Server 2005 - Update 'Service Pack 3 for SQL Server Database Services 2005 ENU (KB955706)' could not be installed. Error code 1603. The detailed dump reveals the following: MSI (s) (90:C8) [13:50:17:776]: Note: 1: 1729 MSI (s) (90:C8) [13:50:17:776]: Transforming table Error. MSI (s) (90:C8) [13:50:17:776]: Note: 1: 2262 2: Error 3: -2147287038 MSI (s) (90:C8) [13:50:17:792]: Transforming table Error. MSI (s) (90:C8) [13:50:17:792]: Transforming table Error. MSI (s) (90:C8) [13:50:17:792]: Note: 1: 2262 2: Error 3: -2147287038 MSI (s) (90:C8) [13:50:17:792]: Transforming table Error. MSI (s) (90:C8) [13:50:17:792]: Note: 1: 2262 2: Error 3: -2147287038 MSI (s) (90:C8) [13:50:17:792]: Transforming table Error. MSI (s) (90:C8) [13:50:17:792]: Note: 1: 2262 2: Error 3: -2147287038 MSI (s) (90:C8) [13:50:17:792]: Transforming table Error. MSI (s) (90:C8) [13:50:17:792]: Note: 1: 2262 2: Error 3: -2147287038 MSI (s) (90:C8) [13:50:17:807]: Transforming table Error. MSI (s) (90:C8) [13:50:17:807]: Transforming table Error. MSI (s) (90:C8) [13:50:17:807]: Note: 1: 2262 2: Error 3: -2147287038 MSI (s) (90:C8) [13:50:17:807]: Transforming table Error. MSI (s) (90:C8) [13:50:17:807]: Note: 1: 2262 2: Error 3: -2147287038 MSI (s) (90:C8) [13:50:17:807]: Transforming table Error. MSI (s) (90:C8) [13:50:17:807]: Note: 1: 2262 2: Error 3: -2147287038 MSI (s) (90:C8) [13:50:17:807]: Product: Microsoft SQL Server 2005 -- Configuration failed. Does it mean anything to anybody? Btw, this Q originally came from SO (936895)

    Read the article

  • Persisting high score table in flash game without a network. (Featuring: HttpListenerException)

    - by bearcdp
    Hi everyone, this question is very programming-centric, but it's for a game so I figured I might as well post it here. I'm doing polishing work on a GGJ '11 game because it will be shown at an indie arcade tomorrow afternoon, and they're expecting our final build in the morning. We'd like to have a high score table that displays during attract mode, but since it's Flash (Flixel) it would require some networking, Mochi, or something to keep a record of these scores. Only problem is the machine we'd be running on probably won't have network access. As a quick solution, I thought I'd just write up a dinky little high score server in C#/.NET that could take basic GET requests for submitting scores and getting the score list. We're talking REAL basic, like blocking while waiting for an incoming request, run & forget console app, etc. There's no guarantee that our .swf won't get reloaded, and we'd like the scores to persist, so this server would pretty much exists to keep a safe copy of the scores that the game can add to and request, and occasionally the server will write the scores to a flat text file. But, HttpListener is giving me Error Code 87 'The parameter is incorrect.' Have any idea what I'm doing wrong? Or better yet, am I barking up the wrong tree and missing an obviously simpler solution? This is all I've got so far in my Main(): HttpListener listener = new HttpListener(); listener.Prefixes.Add("http://localhost:66666/"); listener.Start(); The exception happens at listener.Start(); and the stack trace is: at System.Net.HttpListener.AddAllPrefixes() at System.Net.HttpListener.Start() at WOSEBCE_ScoreServer.Program.Main(String[] args) in C:\Users\Michael\Documents\Visual Studio 2010\VS2010 Projects\WOSEBCE_ScoreServer\WOSEBCE_ScoreServer\Program.cs:line 24 at System.AppDomain._nExecuteAssembly(RuntimeAssembly assembly, String[] args) at System.AppDomain.ExecuteAssembly(String assemblyFile, Evidence assemblySecurity, String[] args) at Microsoft.VisualStudio.HostingProcess.HostProc.RunUsersAssembly() at System.Threading.ThreadHelper.ThreadStart_Context(Object state) at System.Threading.ExecutionContext.Run(ExecutionContext executionContext, ContextCallback callback, Object state, Boolean ignoreSyncCtx) at System.Threading.ExecutionContext.Run(ExecutionContext executionContext, ContextCallback callback, Object state) at System.Threading.ThreadHelper.ThreadStart()

    Read the article

  • My partition table is facing limitations; having problems creating more partitions

    - by Terence
    I first noticed an issue when trying to install Linux Mint 14 as a third OS alongside Ubuntu 12.10 and Windows 7 - I was unable to create another partition to install Mint to. Poking around, I realised that I had reached the limit of primary partitions: (from left to right of the table) 1) a ~100 MB primary partition that I meant to use for storing Grub files but never got down to, 2) a 25 GB extended partition, with the entire partition containing an ext4 Ubuntu partition, 3) a ~513 GB partition containing Windows 7, 4) some ~50 GB of unallocated space, and finally 5) a 4 GB swap partition. I decided to wipe off the first ~100 MB partition, which I didn't need anyway. This brought me to a dilemma, however: as Ubuntu, during initial installation, had created an extended partition for itself, which meant that I could not create any more. Having an extended partition for Ubuntu is virtually useless as there is only enough space to contain Ubuntu itself, and the benefits of extended are worthless here. And if I go ahead and install Mint now, I would face the same issue of too many primary partitions in the future should I want to create any more. What I'd really like to do is this: convert the current extended partition into a normal primary partition, and create a new extended partition in the unallocated space for all future partitions. Is this possible, and if so how? Thanks in advance!

    Read the article

< Previous Page | 186 187 188 189 190 191 192 193 194 195 196 197  | Next Page >