Search Results

Search found 54446 results on 2178 pages for 'struct vs class'.

Page 199/2178 | < Previous Page | 195 196 197 198 199 200 201 202 203 204 205 206  | Next Page >

  • jQuery: How to find and change multiply th classes between n & n

    - by Ravex
    Hi everyone. I have some table structure: <tr class="row-2"><tr> <tr class="row-3">..<tr> <tr class="row-4">..<tr> <tr class="row-5">..<tr> <tr class="row-6">..<tr> <tr class="row-7"><tr> <tr class="row-8">..<tr> <tr class="row-9">..<tr> <tr class="row-10">..<tr> <tr class="row-11">..<tr> ...etc for this example TR with classes "row-2" and "row-7" is parrent product link wich expand child rows. <script> $(function() { $('tr.parent') .css("cursor","pointer") .css("color","red") .attr("title","Click to expand/collapse") .click(function(){ $(this).siblings('.child-'+this.id).toggle(); }); $('tr[@class^=child-]').hide().children('td'); }); </script> Rows -3...-6 is child of row-2 and Rows -8...-11 is child of row-7 How i can find row-2, row-7, etc then add second class "parrent" and ID similar class (id="row-2", id="row-7", etc)? Also i need add in each TR between row-2 and row-7 class equal previous parrent row. In bottom line i need something like this: <tr class="row-2 parrent" id="row-2"><tr> <tr class="row-3 child-row2">..<tr> <tr class="row-4 child-row2">..<tr> <tr class="row-5 child-row2">..<tr> <tr class="row-6 child-row2">..<tr> <tr class="row-7 parrent" id="row-7"><tr> <tr class="row-8 child-row7">..<tr> <tr class="row-9 child-row7">..<tr> <tr class="row-10 child-row7">..<tr> <tr class="row-11 child-row7">..<tr> ..etc Thanks for any Help.

    Read the article

  • What does class_eval <<-"end_eval", __FILE__, __LINE__ mean in Ruby?

    - by viatropos
    I'm learning how to use class_eval in modules (I'm somewhat familiar with class_eval) and came across this helpful class in resource_controller. In there they have things like this: class_eval <<-"end_eval", __FILE__, __LINE__ def #{block_accessor}(*args, &block) unless args.empty? && block.nil? args.push block if block_given? @#{block_accessor} = [args].flatten end @#{block_accessor} end end_eval What does __FILE__ and __LINE__ do in that context? I know __FILE__ references the current file, but what does that whole thing do exactly? Don't really know how to search for that :).

    Read the article

  • Custom Attributes on Class Members

    - by ccook
    I am using a Custom Attribute to define how a class's members are mapped to properties for posting as a form post (Payment Gateway). I have the custom attribute working just fine, and am able to get the attribute by "name", but would like to get the attribute by the member itself. For example: getFieldName("name"); vs getFieldName(obj.Name); The plan is to write a method to serialize the class with members into a postable string. Here's the test code I have at this point, where ret is a string and PropertyMapping is the custom attribute: foreach (MemberInfo i in (typeof(CustomClass)).GetMember("Name")) { foreach (object at in i.GetCustomAttributes(true)) { PropertyMapping map = at as PropertyMapping; if (map != null) { ret += map.FieldName; } } } Thanks in advance!

    Read the article

  • Cisco Nexus 5000 Vs. UCS 6100

    - by radius
    Hello, I'm a bit lost when I take a look to Nexus 5000 and UCS 6100. The description of Nexus 5000 is quite clear and I see what it does but the description of the UCS 6100 is a bit unclear for me. Could someone told me what would be the difference between a Nexus 5000 with all port at 10G and an UCS 6100 with all port at 10G ? Thanks,

    Read the article

  • Apache mod_proxy vs mod_rewrite

    - by Scott
    What is the difference between using mod_proxy and mod_rewrite? I have a requirement to send certain url patterns through the tomcat, which runs on the same host but under port 8080. I know this is something for mod_proxy, but I"m wondering why I can't just use mod_rewrite, or what the difference is? Probably has to do w/ reverse proxy, and also when in the pipeline it gets handled? Thanks.

    Read the article

  • DSL vs Cable latency

    - by tovmeod
    currently I have a 10Mbps DSL line and I'm thinking to switch to a cable since they got 100Mbps for a little less than double the price I'm paying for 10Mbps. In other words the cable company is offering 100Mbps for the price of 20Mbps DSL. Since 10Mbps is more than enough for me I am worried about the latency, I saw this that is just a guy experiment, that shows that cable and DSL are the same in practical terms, and this but I couldn't grasp it, not sure if it is helpful. So my question is if there's any practical difference between cable and DSL, mainly in latency terms but I would be also interested in other advantages/disadvantages. This is for my home connection, I work from home but I don't run any server, I most of the time code, skype and eventually game.

    Read the article

  • svchost.exe @ 100% disk utilization vs. Outlook.ost

    - by Aszurom
    Vista x32 box with Outlook 2007. Outlook is not running. Hasn't been fired up for several reboots. I stopped WMI service and Windows Search service. Machine is mostly quiet, and then servicehost.exe launches an instance and starts banging away at Outlook.ost file. I can't determine what is causing it. I'm watching it in processmon, and trying to investigate it with preocessexplorer. Not having much luck at figuring out why the machine is so interested in that file. NOTHING is running that should be touching it.

    Read the article

  • NAT vs public IP (and blocked ports)

    - by user1646166
    I have a problem with my ISP. They say that they don't block any ports and I have public IP, while I think these both statements are false. Before I talk to them again (which is really tough when my understanding of these terms is different than theirs) I would like to make some things clear. It seems like my computer is behind NAT (is it possible to have public IP and be behind NAT at the same moment?). When I check my IP, through some external server, and type that IP into browser I get a home page of some router (not mine). Isn't that a proof that my IP isn't public? Also, I have problems with making connections via some ports. E.g. when I'm trying to connect through some high port ( 1023) via SSH, it doesn't work. Is it possible that certain range of outgoing ports from my computer are blocked? Or is it simply because that my ssh client (PuTTY) can't receive incoming packets because of blocked incoming ports? To avoid some questions: it's not a problem with my router, I tried connecting my PC directly and it also didn't work, while having connected by 3G using phone with USB tethering, it does work. Thanks!

    Read the article

  • RAID 10: SPAN 2 vs SPAN 4

    - by LaDante Riley
    I am currently configuring RAID 10 (first time doing RAID ever) for a server at work. In the Configuration Utility. I am given the option of either span 2 or span 4. Having never done this before, I was curious if someone could tell me the pros and cons of for each span? Thanks The server is a Poweredge r620 with a PERC H710 mini (Security Capable) RAID controller. I have 8 600GB hard drives. I am creating this server as a network storage drive. I have SQL server historian database whose 1TB storage filled up and after 5 years of logging data.

    Read the article

  • How to Access a Private Variable?

    - by SoulBeaver
    This question isn't meant to sound as blatantly insulting as it probably is right now. This is a homework assignment, and the spec sheet is scarce and poorly designed to say the least. We have a function: double refuel( int liter, GasStation *gs ) { // TODO: Access private variable MaxFuel of gs and decrement. } Sound simple enough? It should be, but the class GasStation comes with no function that accesses the private variable MaxFuel. So how can I access it anyway using the function refuel? I'm not considering creating a function setFuel( int liter ) because the teacher always complains rather energetically if I change his specification. So... I guess I have to do some sort of hack around it, but I'm not sure how to go about this without explicitely changing the only function in GasStation and giving it a parameter so that I can call it here. Any hints perhaps?

    Read the article

  • Extract a C/C++ header file from a C# class exposed to COM

    - by isorfir
    I'm not sure I've setup everything I've needed to in my C# class to properly, but it does work in COM. I've been looking for an example of a C# class that was successfully used in a C/C++ project, but haven't come across anything. I've tried using the OLE/COM Object View app to open the .tlb file and save as .h, but it gives some errors: MIDL1009: unknown argument ignored; MIDL1001: cannot open input file Studio "Studio" isn't the name of the file, it's Syslog, so that raises a red flag to me. Any ideas?

    Read the article

  • nginx www.domain.com vs domain.com virtualhost

    - by m33lky
    I have an http block where I include virtual hosts for the different domains hosted on the same server. For each virtual host I do: listen domain.com:80; Now, domain2.com works fine. However, when I do www.domain2.com it shows the page for domain1.com! How to properly configure nginx? Does this have something to do whether www is a CNAME or an A record? Update: It looks like you can do the following: listen 80; server_name domain.com www.domain.com;

    Read the article

  • Write Scheme data structures so they can be eval-d back in, or alternative

    - by Jesse Millikan
    I'm writing an application (A juggling pattern animator) in PLT Scheme that accepts Scheme expressions as values for some fields. I'm attempting to write a small text editor that will let me "explode" expressions into expressions that can still be eval'd but contain the data as literals for manual tweaking. For example, (4hss->sexp "747") is a function call that generates a legitimate pattern. If I eval and print that, it becomes (((7 3) - - -) (- - (4 2) -) (- (7 2) - -) (- - - (7 1)) ((4 0) - - -) (- - (7 0) -) (- (7 2) - -) (- - - (4 3)) ((7 3) - - -) (- - (7 0) -) (- (4 1) - -) (- - - (7 1))) which can be "read" as a string, but will not "eval" the same as the function. For this statement, of course, what I need would be as simple as (quote (((7 3... but other examples are non-trivial. This one, for example, contains structs which print as vectors: pair-of-jugglers ; --> (#(struct:hand #(struct:position -0.35 2.0 1.0) #(struct:position -0.6 2.05 1.1) 1.832595714594046) #(struct:hand #(struct:position 0.35 2.0 1.0) #(struct:position 0.6 2.0500000000000003 1.1) 1.308996938995747) #(struct:hand #(struct:position 0.35 -2.0 1.0) #(struct:position 0.6 -2.05 1.1) -1.3089969389957472) #(struct:hand #(struct:position -0.35 -2.0 1.0) #(struct:position -0.6 -2.05 1.1) -1.8325957145940461)) I've thought of at least three possible solutions, none of which I like very much. Solution A is to write a recursive eval-able output function myself for a reasonably large subset of the values that I might be using. There (probably...) won't be any circular references by the nature of the data structures used, so that wouldn't be such a long job. The output would end up looking like `(((3 0) (... ; ex 1 `(,(make-hand (make-position ... ; ex 2 Or even worse if I could't figure out how to do it properly with quasiquoting. Solution B would be to write out everything as (read (open-input-string "(big-long-s-expression)")) which, technically, solves the problem I'm bringing up but is... ugly. Solution C might be a different approach of giving up eval and using only read for parsing input, or an uglier approach where the s-expression is used as directly data if eval fails, but those both seem unpleasant compared to using scheme values directly. Undiscovered Solution D would be a PLT Scheme option, function or library I haven't located that would match Solution A. Help me out before I start having bad recursion dreams again.

    Read the article

  • Harvard vs. Von Neumann architecture

    - by user32569
    Hi. Our teacher told us, that Harvard architecture is the most evolved and produced architecture today and towards future. but I thing becouse os massive averhead of x86 and Von Neumann nased ARM systems that actually Von Neumann is the most used architecture today. Yes, MCUs with Harvard are even more produced, but since they all have just minor purpose (compared to x86 and ARM based) that Von Neumann is actually the one. Or is it really Harvard? And second, I know this is strange question, but does any architecture combining both exists? to have separate memory for data and programs, therefore faster instruction processing, but still able to work with these as Von Neumann? To be able o load amd unload programs to program memory on the fly? Isnt this the way the x86 should have go? Or would there be some bottleneck that pure Von neumann solves? Thanks.

    Read the article

  • File creation time on Windows vs Linux

    - by Sergei
    We have following setup: mountserver - debian linux fileserver1 - Windows 2008 R2 Storage server fileserver2 - Celerra NS20 exporting CIFS share workstation - windows 7 with mapped drive to share on fileserver2 What we are doing: mounted share from fileserver1 on mountserver, e.g. /shared/fileserver1 mounted share from fileserver2 on mountserver, e.g. /shared/fileserver2 ran rsync on mountserver to sync data from fileserver1 to fileserver2.Used atime as parameter to sync data not older than X after a while tried to delete data older that Y on /shared/fileserver2. From what I see, linux stat command on mountserver returns following when quering file on /shared/fileserver2: At the same time when I open property for the same file using mapped drive connected to fileserver2,I see following for the same file: As you can see, Created date of 12 August shown in Windows Explorer is nowhere to be seen using stat command Am I missing something here?

    Read the article

  • Routing protocols, distance vector vs link state

    - by Artem Barger
    I'm trying to figure out the differences(pros/cons) between two routing protocols approach and I would be great-full for any help, advice and explanation. As far I can say that it seems like distance vector is more static and more local based routing, since it doesn't know the network state whereas link state is more aware of current states therefore it seems more natural to use it over distance-vector, but I have a feeling like I'm missing something. And I would be glad to here about more aspects and different issues I have to consider while choosing one of them.

    Read the article

  • Adding a second IP address for IIS - static vs dynamic A records

    - by serialhobbyist
    I'm looking to add a second IP address to IIS so that I can run two sites with different SSL certificates. When I added one on my play box and ran ipconfig /registerdns both addresses were registered in DNS with the server's name. So, I deleted the A record for the new IP address and rebooted. That also registered both names. So, then I went into the network config for the adapter and, on the DNS tab, unchecked "Register this connection's addresses in DNS". I deleted the A record for the new IP address again and re-ran ipconfig /registerdns. This time, it deleted the A record for the old IP address and didn't created one for the new address. Neither of these is what I want: I want the main IP address to be registered and refreshed automatically as a dynamic DNS record and the second IP address to be registered and managed as a static address. Is there any way to achieve this?

    Read the article

  • Reconciling vmware memory vs windows memory usage

    - by RyanW
    I have a Windows 2008 R2 64 bit virtual machine on ESXi 4.1 host. The host reports that the virtual machine is actively using less than 1 GB of memory. But, in Windows it's reporting the machine is using 7 GB of memory, even though the total of the processes listed in task manager is less than 1 GB. The machine is rather unresponsive and I'm concerned this is impacting other applications (server's purpose is to run ASP.NET state server process, which has been having trouble and led me to spot the memory question). I just noticed High memory usage Windows Server 2008r2 on VMware and will be looking through those documents more, but what is causing this?

    Read the article

  • VS 2008 Profiler - Caller/Callee view showing bottom of stack

    - by Ncc
    Hello, I am currently trying to profile a class contained in a different assembly. To do this I created a small console application which calls into the public entry point of the class I want to profile. This enrty point is called Run(). This is working fine when I run my Console application in Debug mode and I can step into the Run() method. The Run() method calls a variety of other methods in its own assembly and other assemblies. However, when I create a new profiler of type "Instrumentation" in VS 2008, and run the profiler, the report shows my Main() function calling Run(), but in turn, when viewing the Caller/Callee report for my Run() method the report shows that the Run() method is the bottom of the stack. This is clearly not the case - could anyone please suggest why this is happening? Thanks.

    Read the article

  • UPS vs Solar Power in case of power failure for a server [on hold]

    - by Zen 8000k
    I am looking for a low power, low end pc able to run 24/7 without overheating and a way to support it in case of power failure. Power failures can be up to 72 hours. The pc dosen't need a monitor or keyboard. A modem must also be protected in case of power failure. When i say low end, i don't mean crap. The cpu needs to be x86 and have at least 1k cpu in this chart: http://www.cpubenchmark.net/index.php What's the best way to do this? EDIT: more info. I need to run a home server. The server will perform light tasks mainly. A x86 cpu sadly is the only route for my use. I want to be able to run the server and the router/modem in case of power failure. Now, regarding how long the power will fail: 1) 1 hours is OK for most situations. (say 90%) 2) 3 hours is OK (say 98%) 3) 6 hours is more thank OK. (say 99.5%) 4) On extreme cases the power might fail days. I believe this is very unlikely to happen. More is great but, really, how ofter power will fail more than 3 hours? I believe once every year at best. Well, that's too rare to care about. Given the above, I am looking for a cost effective way to archive 1-3 hour power or 6 hour if possible. Solutions: You guys give me great ideas. 1) Power generator: no good as power will fail for 10 seconds before returning. Also I read online, "clean" power generators cost 1.5k+, so it's out of budged. Non clean generator might damage electronics, right? 2) Solar power: i don't know for sure about this. Sounds like a great idea, too good to be true, honestly. For only 200$ i get 100+w? What are the drawbacks here? 3) UPS: This seems to be the best. The only problem is the cost. Cost < 200$ = great 400$ = budged limit

    Read the article

  • Advantages of a 130W vs 90W ac adapter?

    - by David
    I purchased a Lenovo T420S laptop with a 90W/20V AC adapter P/N 42t4426 through my IT department. Subsequently, I ordered a replacement adapter and received a 135W/20V AC adapter P/N 45N0054. The 135W version is about twice as big and heavy as the 90W version. Is there an advantage to the 135W version like faster battery recharging? Are there any negative effects (other than weight), like reduced battery life?

    Read the article

  • Data Archiving vs not

    - by Recursion
    For the sake of data integrity, is it wiser to archive your files or just leave them unarchived. No compression is being used. My thinking is that if you leave your files unarchived, if there is some form of corruption it will only hurt a smaller number of files. Though if you archive, lets say all of your documents, if there is even the slightest corruption, the entire archive is unrecoverable. So whats the best way to keep a clean file system, but not be subject to data corruption.

    Read the article

  • SpeedTracer NETWORK_RESOURCE_RESPONSE vs NETWORK_RESOURCE_FINISH

    - by Ben Flynn
    I'm using SpeedTracer with GoogleChrome to measure the load times of requested resources. The SpeedTracer site says: NETWORK_RESOURCE_RESPONSE "Indicates that the renderer has started receiving bits from the resource loader" NETWORK_RESOURCE_FINISH "Indictes a resource load is successful and complete." In my mind that means we would always see a network resource response (bytes are arriving) before we see a finish (all bytes received). This doesn't seem to be the case at all. Here is a sample: Request Timing @33519ms for 926ms Response Timing @34445ms for -847ms Total Timing @33519ms for 78ms I'm guessing response time isn't supposed to be negative. Can someone explain this or is this a bug? I'm using Chrome 10.0.612.3 dev with a SpeedTracer I downloaded today.

    Read the article

  • Script or automate feature class creation in ESRI/ArcSDE

    - by Keith G
    I'm looking for info on how to write SQL scripts to automate the creation of a versioned feature class in ArcSDE I want to be able to automate the process itself as well as put the scripts under version control. Can anyone point me to a resource that explains how to do this? Is this even possible? It seems like there are lots of interrelationships between tables and data when a feature class is added. P.S. It doesn't have to be pure SQL, but it should be some kind of scripting so we can save to version control and run outside of ESRI desktop tools.

    Read the article

  • C# Changing class method at run-time

    - by Flavio
    Hi, I need to extend the behavior of an instance, but I don't have access to the original source code of that instance. For example: /* I don't have the source code for this class, only the runtime instance */ Class AB { public void execute(); } in my code I would to intercept every call to execute, compute some sutff and then call the original execute, something like /* This is how I would like to modify the method invokation */ SomeType m_OrgExecute; { AB a = new AB(); m_OrgExecute = GetByReflection( a.execute ); a.execute = MyExecute; } void MyExecute() { System.Console.Writeln( "In MyExecute" ); m_OrgExecute(); } Is that possible? Does anyone have a solution for this problem?

    Read the article

< Previous Page | 195 196 197 198 199 200 201 202 203 204 205 206  | Next Page >