Search Results

Search found 746 results on 30 pages for 'winapi'.

Page 20/30 | < Previous Page | 16 17 18 19 20 21 22 23 24 25 26 27  | Next Page >

  • Can somebody explain this remark in the MSDN CreateMutex() documentation about the bInitialOwner fla

    - by Tom Williams
    The MSDN CreatMutex() documentation (http://msdn.microsoft.com/en-us/library/ms682411%28VS.85%29.aspx) contains the following remark near the end: Two or more processes can call CreateMutex to create the same named mutex. The first process actually creates the mutex, and subsequent processes with sufficient access rights simply open a handle to the existing mutex. This enables multiple processes to get handles of the same mutex, while relieving the user of the responsibility of ensuring that the creating process is started first. When using this technique, you should set the bInitialOwner flag to FALSE; otherwise, it can be difficult to be certain which process has initial ownership. Can somebody explain the problem with using bInitialOwner = TRUE? Earlier in the same documentation it suggests a call to GetLastError() will allow you to determine whether a call to CreateMutext() created the mutex or just returned a new handle to an existing mutex: Return Value If the function succeeds, the return value is a handle to the newly created mutex object. If the function fails, the return value is NULL. To get extended error information, call GetLastError. If the mutex is a named mutex and the object existed before this function call, the return value is a handle to the existing object, GetLastError returns ERROR_ALREADY_EXISTS, bInitialOwner is ignored, and the calling thread is not granted ownership. However, if the caller has limited access rights, the function will fail with ERROR_ACCESS_DENIED and the caller should use the OpenMutex function.

    Read the article

  • Removing and restoring Window borders

    - by Laurence
    I want to remove the window borders of another process in C#; I used RemoveMenu to remove the borders. It almost works but I have 2 problems left: I need to remove the borders twice, the first time the menu bar still exists. I can’t restore the menu’s This is what I already wrote: public void RemoveBorders(IntPtr WindowHandle, bool Remove) { IntPtr MenuHandle = GetMenu(WindowHandle); if (Remove) { int count = GetMenuItemCount(MenuHandle); for (int i = 0; i < count; i++) RemoveMenu(MenuHandle, 0, (0x40 | 0x10)); } else { SetMenu(WindowHandle,MenuHandle); } int WindowStyle = GetWindowLong(WindowHandle, -16); //Redraw DrawMenuBar(WindowHandle); SetWindowLong(WindowHandle, -16, (WindowStyle & ~0x00080000)); SetWindowLong(WindowHandle, -16, (WindowStyle & ~0x00800000 | 0x00400000)); } Can someone show me what I did wrong? I already tried to save the MenuHandle and restore it later, but that doesn't work.

    Read the article

  • Closing a window when it's "no longer needed".

    - by Mason Blier
    This is kind of a hard question to describe, and I've searched for about an hour now to no avail. Essentially, picture a small 'flyout' window like the Windows 7 Wireless Control or the Volume Slider from the system tray(notification area). When you click on the icon, the application pops up with focus, and if you click off of it, the window destroys itself. I thought it woudl be easily solved by simply having my window destroy it self when it loses focus (I've been listening for WM_KILLFOCUS), but the problem is, if the icon is clicked, my window does not always get focus. Since this isn't the case, if the user clicks my icon, and then clicks away because it was a mistake (on the desktop say), then how can I set my app to close? I've tried messing with SPY++ but checking the volume control / wireless control apps are proving difficult as they disappear when I try to get their window/process handles. Thanks!

    Read the article

  • How to lock file in Windows?

    - by matsoor
    How to lock file in Windows so that this file can be opened/read/wrote only by one process? I found out that file can be locked with CreateFile by giving 0 to dwShareMode flag. It works but only the returned handle can be used to work with file. But I want to be able to lock the file to other processes and at the same time to create multiple handles in my process. Please help me to solve this issue or give some tips...

    Read the article

  • WM_SYSCOMMAND oddities

    - by Andreas Rejbrand
    An application recieves the WM_SYSCOMMAND message when the user selects a menu item command on the system menu, and so wParam can be SC_CLOSE, SC_CONTEXTHELP, SC_MAXIMIZE, SC_MINIMIZE, SC_RESTORE etc. That's logical. But one can also send the WM_SYSCOMMAND message to send commands to the Windows Shell. For instance, one can display the start menu (SC_TASKLIST), activate the screen saver (SC_SCREENSAVE), and turn off the monitor (SC_MONITORPOWER). This does not make sense, does it? What does this have to do with the application's system menu? This is more of a "system command", i.e. more of a completely other interpretation of the name "WM_SYSCOMMAND" of the message. It's like the message is used to send command requests to the system. Why is this message used for two seemingly entirely different things, and what thing does the name "SYSCOMMAND" refer to (command on the system menu, or command of the operating system)?

    Read the article

  • Can't open COM1 from application launched at startup

    - by n0rd
    I'm using WinLIRC with IR receiver connected to serial port COM1 on Windows 7 x64. WinLIRC is added to Startup folder (Start-All applications-Startup) so it starts every time I log in. Very often (but not all the time) I see initialization error messages from WinLIRC, which continue for some time (couple of minutes) if I retry initialization, and after some retries it initializes correctly and works fine. If I remove it from Startup and start manually at any other moment it starts without errors. I've downloaded WinLIRC sources and added MessageBox calls here and there so I can see what happens during initialization and found out that CreateFile call fails: if((hPort=CreateFile( settings.port,GENERIC_READ | GENERIC_WRITE, 0,0,OPEN_EXISTING,FILE_FLAG_OVERLAPPED,0))==INVALID_HANDLE_VALUE) { char buffer[256]; sprintf_s(buffer, "CreateFile(%s) failed with %d", settings.port, GetLastError()); MessageBox(NULL, buffer, "debug", MB_OK); hPort=NULL; return false; } I see message box saying "CreateFile(COM1) failed with 5", and 5 is an error code for "Access denied" error according to this link. So the question is why opening COM-port can fail with such error right after booting Windows and proceed normally few seconds or minutes later?

    Read the article

  • Native API window designer

    - by Ricardo
    Why isn't there a designer for native api forms in Visual Studio? Similar to Delphi? If there exist some programs, tools etc, please advice. What is the best approach to design complex windows in pure API?

    Read the article

  • Multimonitor taskbar in .Net

    - by kalan
    I have an idea to write a multimotor taskbar application in c# for windows xp. So, does anyone have any information how to put a taskbar on the second monitor, to make it use windows styles, to prevent aplications running on the second monitor to appear in default taskbar, so on... Any help would be ...helpful )))

    Read the article

  • How to get only USB devices not all the devices in the system

    - by new
    Grretings to all, I get devices list from the system. but i am not sure that if i want to get only the usb devices currently in the system means , What class i must specify in the below code ( DWORD Flags ) hDevInfo = SetupDiGetClassDevs(&GUID_DEVINTERFACE_USB_DEVICE, 0, // Enumerator 0, DIGCF_PRESENT | DIGCF_INTERFACEDEVICE );

    Read the article

  • throwing exception from APCProc crashes program

    - by lazy_banana
    I started to do some research on how terminate a multithreaded application properly and I found those 2 post(first, second) about how to use QueueUserAPC to signal other threads to terminate. I thought I should give it a try, and the application keeps crashing when I throw the exception from the APCProc. Code: #include <stdio.h> #include <windows.h> class ExitException { public: char *desc; DWORD exit_code; ExitException(char *desc,int exit_code): desc(desc), exit_code(exit_code) {} }; //I use this class to check if objects are deconstructed upon termination class Test { public: char *s; Test(char *s): s(s) { printf("%s ctor\n",s); } ~Test() { printf("%s dctor\n",s); } }; DWORD CALLBACK ThreadProc(void *useless) { try { Test t("thread_test"); SleepEx(INFINITE,true); return 0; } catch (ExitException &e) { printf("Thread exits\n%s %lu",e.desc,e.exit_code); return e.exit_code; } } void CALLBACK exit_apc_proc(ULONG_PTR param) { puts("In APCProc"); ExitException e("Application exit signal!",1); throw e; return; } int main() { HANDLE thread=CreateThread(NULL,0,ThreadProc,NULL,0,NULL); Sleep(1000); QueueUserAPC(exit_apc_proc,thread,0); WaitForSingleObject(thread,INFINITE); puts("main: bye"); return 0; } My question is why does this happen? I use mingw for compilation and my OS is 64bit. Can this be the reason?I read that you shouldn't call QueueApcProc from a 32bit app for a thread which runs in a 64bit process or vice versa, but this shouldn't be the case.

    Read the article

  • C++ MFC add combo box string item from a widget ID

    - by OzBarry
    I've added a combo box in the gui editor in MSVC 2010 pro in my MFC project. I have a list of strings I am grabbing from an external source and want to add them to my combo box. I've searched for a while, and every post seems to suggest I need to use the CComboBox class, however, I have no idea how to get the class variable from the resource ID of the combobox element in the gui editor. In summary, how do I add a string to my combo box, either using a macro (like CB_ADDSTRING(RESOURCE_ID, "my string");) or using CComboBOx (something like CComboBox::GetObject(RESOURCE_ID)->AddString("blah");). I do not do much win32 api/mfc programming, and just started fiddling around with it.

    Read the article

  • Help Using NetuserAdd() and NetLocalGroupAddMembers() in C++

    - by Brett Powell
    So I think I almost got it. I create my dummy account with one function, and wrote a second function to add it to the Remote Desktop group. Problem is, the Administrator account is the one logged in, so I am not sure how to specify what account to add to the group. Here is my code... The user is being created properly... void AddRDPUser() { USER_INFO_1 ui; DWORD dwLevel = 1; DWORD dwError = 0; NET_API_STATUS nStatus; ui.usri1_name = L"BrettXFactor"; ui.usri1_password = L"XfactorsServer96"; ui.usri1_priv = USER_PRIV_USER; ui.usri1_home_dir = NULL; ui.usri1_comment = NULL; ui.usri1_flags = UF_SCRIPT; ui.usri1_script_path = NULL; nStatus = NetUserAdd(NULL, dwLevel, (LPBYTE)&ui, &dwError); } But I dont know how to specify to add them to this group since they are not logged in. Any help would be appreciated void AddToGroup() { LOCALGROUP_MEMBERS_INFO_3 lgmi3; DWORD dwLevel = 3; DWORD totalEntries = 1; NET_API_STATUS nStatus; LPCWSTR TargetGroup = L"Remote Desktop Users"; LPSTR sBuffer = NULL; memset(sBuffer, 0, 255); DWORD nBuffSize = sizeof(sBuffer); if(GetUserNameEx(NameDnsDomain, sBuffer, &nBuffSize)==0) { Msg("Failed to add User to Group\n"); return; } LPWSTR user_name = (LPWSTR)sBuffer; lgmi3.lgrmi3_domainandname = user_name; nStatus = NetLocalGroupAddMembers(NULL, TargetGroup, 3, (LPBYTE)&lgmi3, totalEntries); }

    Read the article

  • Accessing and inheriting Windows Message for other Windows Message in Delphi

    - by HX_unbanned
    I am using WMSysCommand messages to modify Caption bar button ( Maximize / Minimize ) behaivor and recent update requiered to use WMNCHitTest, but I do not want to split these two related messages in multiplie procedures because of lengthy code. Can I access private declaration ( message ) from other message? And if I can - How to do it? procedure TForm1.WMNCHitTest(var Msg: TWMNCHitTest) ; begin SendMessage(Handle, HTCAPTION, WM_NCHitTest, 0); // or other wParam or lParam ???? end; procedure TForm1.WMSysCommand; begin if (Msg.CmdType = SC_MAXIMIZE or 61488) or (Msg.Result = htCaption or 2) then // if command is Maximize or reciever message of Caption Bar click begin if CheckWin32Version(6, 0) then Constraints.MaxHeight := 507 else Constraints.MaxHeight := 499; Constraints.MaxWidth := 0; end else if (Msg.CmdType = SC_MINIMIZE or 61472) or (Msg.Result = htCaption or 2) then // if command is Minimize begin if (EnsureRange(Width, 252, 510) >= (510 / 2)) then PreviewOpn.Caption := '<' else PreviewOpn.Caption := '>'; end; DefaultHandler(Msg); // reset Message handler to default ( Application ) end; Soo ... do I think correctly and sipmly do not know correct commands or I am thinking total bullsh*t? Regards. Thanks for any help...

    Read the article

  • Alternate for MoveTo and LineTo in win32, MFC

    - by mukesh
    Hi i am working on some high resolution display features in which have to draw the vertical line , i am using Moveto() and lineTO() , but it is much time taking... can anyone suggest me , what we can use instead of it ...to optimize the performance... see the scene is , in order to draw 100 Vertical lines it is taking 84ms time, we need to reduce it to 5 ms something.. please refer me any alternate fot that. Thanks, Mukesh

    Read the article

  • Raising event on reading file?

    - by blez
    I have external app reading files, I want to hook that to get event in my app. But I cannot find a sources hooking ReadFile (or something else that can help me achieve that). Any ideas how to do that? It must be done in User-Mode. I was thinking for something similar to Process Monitor. I wonder how it does it..

    Read the article

  • How can I set different Tooltip text for each item in a listbox?

    - by Michael Lang
    I have a listbox that is databound to a Collection of objects. The listbox is configured to display an identifier property of each object. I would like to show a tooltip with information specific to the item within the listbox that is being hovered over rather than one tooltip for the listbox as a whole. I am working within WinForms and thanks to some helpful blog posts put together a pretty nice solution, which I wanted to share. I'd be interested in seeing if there's any other elegant solutions to this problem, or how this may be done in WPF.

    Read the article

  • Windows API Textfield with offset characters

    - by genesys
    Hi there! Is it possible using the Windows API, to create a textfield that lets me offset characters by exact pixels? if so - how? for example, I would like to place two O letters on top of each other, such that they form something like an 8 ? context is an application for a language where most of the glyphs are written left to right, but sometimes some of the glyphs are stacket on top of each other. Windows API because the framework we're using already uses the Windows API for the whole GUI. Thanks!

    Read the article

  • How can I (is there a way to) convert an HRESULT into a system specific error message?

    - by Billy ONeal
    According to this, there's no way to convert a HRESULT error code into a Win32 error code. Therefore (at least to my understanding), my use of FormatMessage in order to generate error messages (i.e. std::wstring Exception::GetWideMessage() const { using std::tr1::shared_ptr; shared_ptr<void> buff; LPWSTR buffPtr; DWORD bufferLength = FormatMessageW( FORMAT_MESSAGE_FROM_SYSTEM | FORMAT_MESSAGE_ALLOCATE_BUFFER | FORMAT_MESSAGE_IGNORE_INSERTS, NULL, GetErrorCode(), 0, reinterpret_cast<LPWSTR>(&buffPtr), 0, NULL); buff.reset(buffPtr, LocalFreeHelper()); return std::wstring(buffPtr, bufferLength); } ) does not work for HRESULTs. How do I generate these kinds of system-specific error strings for HRESULTs?

    Read the article

  • Virtualization of Legacy API and co-existence with more modern API?

    - by Pharaun
    I don't mean for this question to be a flame bait but I'll be using Microsoft and their win32 API as a example of a legacy API. Now what I am wondering here is Microsoft is spending a lots of their money and energy in maintaining their legacy API, including all of the "glitches/bugs/workaround" that are needed to keep the API functioning the same. Now I'm aware that in Windows 7 they are providing a way for the customer to run their application in a "Windows XP" VM which would be one such way for them to start cleaning up their win32 API because they could then push all of the application into the "Windows XP" VM. So now what I am wondering is, is it possible to virtualization a legacy API in such way that an customer/program can still access and use it, yet at the same time be able to take advantage of the newer version/API? Because as far as I understand it, if the application is ran in the "Windows XP" VM, it won't be able to access any of the newer API/feature of Windows 7.

    Read the article

  • How to make a single line systabcontrol32 that scrolls but doesn't show a scrollbar

    - by TheNewbie
    Hi I'm creating a systabcontrol32 control with the TCS_SINGLELINE style when I resize my window so the tab won't fit an up-down control appears that should allow me to scroll so I can see all the tabs. The thing is that the up-down buttons don't seem to work unless I add a the WS_HSCROLL property to the tab control witch makes it ugly as hell. It could be cool if the up-down could scroll the tabs without need to add the scrollbar (even more since the scroll bar doesn't seem to work, it just sits there and I can't click it).

    Read the article

  • why create CLSID_CaptureGraphBuilder2 instance always failed in a machine

    - by Yigang Wu
    It's a real strange issue, the machine information below is from DXDiag. There is no error reported, but create CLSID_CaptureGraphBuilder2 instance always failed in the machine. It's okay to create CLSID_FilterGraph. Before create CLSID_CaptureGraphBuilder2, I have called CoInitialize and created CLSID_FilterGraph. Only this machine has the error, what dll related with this interface or any function needed to call before to make it work? Thanks in advance. System Information Time of this report: 4/24/2010, 09:46:58 Machine name: TURION Operating System: Windows XP Home Edition (5.1, Build 2600) Service Pack 3 (2600.xpsp_sp3_qfe.100216-1510) Language: Japanese (Regional Setting: Japanese) System Manufacturer: To Be Filled By O.E.M. System Model: MS-7145 BIOS: Default System BIOS Processor: AMD Turion(tm) 64 Mobile Technology MT-30, MMX, 3DNow, ~1.6GHz Memory: 768MB RAM Page File: 376MB used, 1401MB available Windows Dir: C:\WINDOWS DirectX Version: DirectX 9.0c (4.09.0000.0904) DX Setup Parameters: Not found DxDiag Version: 5.03.2600.5512 32bit Unicode DxDiag Notes DirectX Files Tab: No problems found. Display Tab 1: No problems found. Sound Tab 1: No problems found. Sound Tab 2: No problems found. Music Tab: No problems found. Input Tab: No problems found. Network Tab: No problems found.

    Read the article

< Previous Page | 16 17 18 19 20 21 22 23 24 25 26 27  | Next Page >