Search Results

Search found 6343 results on 254 pages for 'dll injection'.

Page 225/254 | < Previous Page | 221 222 223 224 225 226 227 228 229 230 231 232  | Next Page >

  • Constant error in compiler using C#'s provided objects

    - by dotnetdev
    I have used the built in C# methods to write a compiler, like the following: CodeDomProvider codeProvider = CodeDomProvider.CreateProvider("CSharp"); string Output = "Out.exe"; Button ButtonObject = (Button)sender; this.RadTextBox1.Text = string.Empty; System.CodeDom.Compiler.CompilerParameters parameters = new CompilerParameters(); //Make sure we generate an EXE, not a DLL parameters.GenerateExecutable = true; parameters.OutputAssembly = Output; CompilerResults results = codeProvider.CompileAssemblyFromSource(parameters, RadTextBox1.Text); if (results.Errors.Count > 0) { RadTextBox2.ForeColor = Color.Red; foreach (CompilerError CompErr in results.Errors) { RadTextBox2.Text = RadTextBox2.Text + "Line number " + CompErr.Line + ", Error Number: " + CompErr.ErrorNumber + ", '" + CompErr.ErrorText + ";" + Environment.NewLine + Environment.NewLine; } } else { //Successful Compile RadTextBox2.ForeColor = Color.Blue; Guid guid = Guid.NewGuid(); string PathToExe = Server.MapPath(Path.Combine(@"\Compiled" , Output)); FileStream fs = System.IO.File.Create(PathToExe); using (StreamWriter sw = new StreamWriter(fs)) { sw.Write(RadTextBox1.Text); } Response.WriteFile(PathToExe); When I run this code and write a Main method (such as the code sample in http://msdn.microsoft.com/en-us/library/ms228506(VS.80).aspx, I get this error: Line number 0, Error Number: CS5001, 'Program 'c:\Program Files\Microsoft Visual Studio 9.0\Common7\IDE\Out.exe' does not contain a static 'Main' method suitable for an entry point; The code above is used as the basis of a compiler on my site (not yet live). So you type in code and generate an .exe assembly. But when I enter code into the textbox for code writing (Radtextbox1), even with a main method, I get the error. What gives? Thanks

    Read the article

  • What type of things can cause sgen msbuild task to fail intermittantly with Access Violation?

    - by Mark Allanson
    In our MSBuild file for our project we sgen an assembly containing classes used during xml serialization. The classes are generated via xsd.exe. We use the following SGen task configuration. <SGen ToolPath="$(SdkPath)" ShouldGenerateSerializer="true" UseProxyTypes="false" BuildAssemblyName="AssemblyName.dll" BuildAssemblyPath="Outputs" ContinueOnError="false" /> Intermittantly the following error is thrown when executing the msbuild script on our build server. Originally this error might have occurred once out of every 50 (CI) builds, recently the frequency has been increasing and it now occurs maybe 5-6 out of every 10 builds. The size of the assembly that is being Sgenned is about 410k (circa 35,000 lines of generated code), and when successfull the serialization assembly is about 1.7M in size. When it fails, the output is as follows: Unhandled Exception: System.AccessViolationException: Attempted to read or write protected memory. This is often an indication that other memory is corrupt. E:\Path_ToBuild_Workspace\SolutionBuild.MSBuild(74,5): error MSB6006: "sgen.exe" exited with code -1073741819. We are using Hudson to manage our builds, so the msbuild and sgen processes are therefore spwaned by the Hudson.exe. There's not much out there on the interwebs regarding this type of error from SGen. Certainly nothing concrete.

    Read the article

  • VB.net Saving an MetaFile / EMF as a bitmap ( .tiff)

    - by pehaada
    Currently I have a third party control that generates a Metafile. I can save the .wmf file to disk with out issue. The problem is how do I render the Metafile as a Tiff file. Currently I have the following code to get my metafile and save it. Dim mf As Metafile = page.GetImage(TXTextControl.Page.PageContent.All) Dim enhMetafileHandle As IntPtr = mf.GetHenhmetafile() Dim h As IntPtr Dim bufferSize As UInteger = GetEnhMetaFileBits(enhMetafileHandle, 0, h) Dim buffer(CInt(bufferSize)) As Byte GetEnhMetaFileBits(enhMetafileHandle, bufferSize, buffer) Dim msMetafileStream As New MemoryStream msMetafileStream.Write(buffer, 0, CInt(bufferSize)) Dim baMetafileData() As Byte baMetafileData = msMetafileStream.ToArray Dim g As Graphics = Graphics.FromImage(mf) mf.Dispose() File.WriteAllBytes("c:\a.wmf", baMetafileData) end sub _ Public Shared Function GetEnhMetaFileBits( ByVal hEMF As System.IntPtr, ByVal nSize As UInteger, ByVal lpData As IntPtr) As UInteger End Function <System.Runtime.InteropServices.DllImportAttribute("gdi32.dll", EntryPoint:="GetEnhMetaFileBits")> _ Public Shared Function GetEnhMetaFileBits(<System.Runtime.InteropServices.InAttribute()> ByVal hEMF As System.IntPtr, ByVal nSize As UInteger, ByVal lpData() As Byte) As UInteger End Function I've tried all sort of IMAGE and Graphic calls and just can't save the meta file as a .tiff. Any suggestions would be great. I even tried to create a new bitmap and draw the metafile onto it. I always end up with a GDI exception being thrown.

    Read the article

  • Dynamic Connection Strings for Strongly Typed DataSet in a Class Library using App.Config

    - by Luc
    This is my first question on StackOverflow.com and I'm not sure if this is the correct way to do this. I found a similar question titled: Modifying the Data Source for the Strongly Typed Dataset Connection String. However, the answer provided is not working for me. I'm not able to comment on it because I don't have enough "reputation points" (again, I just signed up), and I didn't want to provide an "answer", because I don't know the correct answer. My problem is that I need to be able to modify the connection string inside the generated myproject.dll.config file, but doing so has no effect for me at all. My library still uses the default connection string that was setup at design time. I've tried everything I know to try, but still no luck. I've tried working around the issue using multiple different approaches, but still the problem persists. I can't find any help on the internet with my specific problem either. It would be great if somebody could shed some light as to why my modified config file isn't being read. Useful information: I'm using a Strongly Typed DataSet I don't know the actual connection string at design time. The app.config doesn't allow me to specify a 'User' scoped connection string. I'm tied to a class library (no Windows Forms) Thank you for any help! Luc

    Read the article

  • Java Access Token PKCS11 Not found Provider

    - by oracleruiz
    Hello I'm trying to access the keystore from my smartcard in Java. And I'm using the following code.. I'm using the Pkcs11 implementation of OpenSc http://www.opensc-project.org/opensc File windows.cnf = name=dnie library=C:\WINDOWS\system32\opensc-pkcs11.dll Java Code = String configName = "windows.cnf" String PIN = "####"; Provider p = new sun.security.pkcs11.SunPKCS11(configName); Security.addProvider(p); KeyStore keyStore = KeyStore.getInstance("PKCS11", "SunPKCS11-dnie"); =)(= char[] pin = PIN.toCharArray(); keyStore.load(null, pin); When the execution goes by the line with =)(= throws me the following exeption java.security.KeyStoreException: PKCS11 not found at java.security.KeyStore.getInstance(KeyStore.java:635) at ObtenerDatos.LeerDatos(ObtenerDatos.java:52) at ObtenerDatos.obtenerNombre(ObtenerDatos.java:19) at main.main(main.java:27) Caused by: java.security.NoSuchAlgorithmException: no such algorithm: PKCS11 for provider SunPKCS11-dnie at sun.security.jca.GetInstance.getService(GetInstance.java:70) at sun.security.jca.GetInstance.getInstance(GetInstance.java:190) at java.security.Security.getImpl(Security.java:662) at java.security.KeyStore.getInstance(KeyStore.java:632) I think the problem is "SunPKCS11-dnie", but I don't know to put there. I had tried with a lot of combinations... Anyone can help me...

    Read the article

  • VS 2008 does not understand .resource files

    - by Dmitry
    I'm trying to add globalization support to my C# application. According to MSDN, there should be one embedded resource file for neutral culture and satellite DLLs with resource files for other cultures. I've created 2 satellite DLLs without any problems and got my app to automatically load right one using ResourceManager. But I can't embed default neutral culture resource file into my executable. When I remove all satellite DLLs or set culture to some culture I don't have satellite DLL for, I get exception "Could not find any resources appropriate for the specified culture or the neutral culture." when application attempts to create ResourceManager. It looks like VS 2008 does not include my .resource file into main assembly. I've tried different ways to get resource file embedded: compiling it by resgen.exe from text file and adding it to the project; changing its name to add second .resources extension; creating .resx file with same name; etc. And I still don't see the way to get resource file embedded and used by ResourceManager - I'm having same exception. What is the right way to add default neutral culture resource file to application in VS 2008 ?

    Read the article

  • Inserting instructions into method.

    - by Alix
    Hi, (First of all, this is a very lengthy post, but don't worry: I've already implemented all of it, I'm just asking your opinion.) I'm having trouble implementing the following; I'd appreciate some help: I get a Type as parameter. I define a subclass using reflection. Notice that I don't intend to modify the original type, but create a new one. I create a property per field of the original class, like so: [- ignore this text here; I had to add something or the formatting wouldn't work <-] public class OriginalClass { private int x; } public class Subclass : OriginalClass { private int x; public int X { get { return x; } set { x = value; } } } [This is number 4! Numbered lists don't work if you add code in between; sorry] For every method of the superclass, I create an analogous method in the subclass. The method's body must be the same except that I replace the instructions ldfld x with callvirt this.get_X, that is, instead of reading from the field directly I call the get accessor. I'm having trouble with step 4. I know you're not supposed to manipulate code like this, but I really need to. Here's what I've tried: Attempt #1: Use Mono.Cecil. This would allow me to parse the body of the method into human-readable Instructions, and easily replace instructions. However, the original type isn't in a .dll file, so I can't find a way to load it with Mono.Cecil. Writing the type to a .dll, then load it, then modify it and write the new type to disk (which I think is the way you create a type with Mono.Cecil), and then load it seems like a huge overhead. Attempt #2: Use Mono.Reflection. This would also allow me to parse the body into Instructions, but then I have no support for replacing instructions. I've implemented a very ugly and inefficient solution using Mono.Reflection, but it doesn't yet support methods that contain try-catch statements (although I guess I can implement this) and I'm concerned that there may be other scenarios in which it won't work, since I'm using the ILGenerator in a somewhat unusual way. Also, it's very ugly ;). Here's what I've done: private void TransformMethod(MethodInfo methodInfo) { // Create a method with the same signature. ParameterInfo[] paramList = methodInfo.GetParameters(); Type[] args = new Type[paramList.Length]; for (int i = 0; i < args.Length; i++) { args[i] = paramList[i].ParameterType; } MethodBuilder methodBuilder = typeBuilder.DefineMethod( methodInfo.Name, methodInfo.Attributes, methodInfo.ReturnType, args); ILGenerator ilGen = methodBuilder.GetILGenerator(); // Declare the same local variables as in the original method. IList<LocalVariableInfo> locals = methodInfo.GetMethodBody().LocalVariables; foreach (LocalVariableInfo local in locals) { ilGen.DeclareLocal(local.LocalType); } // Get readable instructions. IList<Instruction> instructions = methodInfo.GetInstructions(); // I first need to define labels for every instruction in case I // later find a jump to that instruction. Once the instruction has // been emitted I cannot label it, so I'll need to do it in advance. // Since I'm doing a first pass on the method's body anyway, I could // instead just create labels where they are truly needed, but for // now I'm using this quick fix. Dictionary<int, Label> labels = new Dictionary<int, Label>(); foreach (Instruction instr in instructions) { labels[instr.Offset] = ilGen.DefineLabel(); } foreach (Instruction instr in instructions) { // Mark this instruction with a label, in case there's a branch // instruction that jumps here. ilGen.MarkLabel(labels[instr.Offset]); // If this is the instruction that I want to replace (ldfld x)... if (instr.OpCode == OpCodes.Ldfld) { // ...get the get accessor for the accessed field (get_X()) // (I have the accessors in a dictionary; this isn't relevant), MethodInfo safeReadAccessor = dataMembersSafeAccessors[((FieldInfo) instr.Operand).Name][0]; // ...instead of emitting the original instruction (ldfld x), // emit a call to the get accessor, ilGen.Emit(OpCodes.Callvirt, safeReadAccessor); // Else (it's any other instruction), reemit the instruction, unaltered. } else { Reemit(instr, ilGen, labels); } } } And here comes the horrible, horrible Reemit method: private void Reemit(Instruction instr, ILGenerator ilGen, Dictionary<int, Label> labels) { // If the instruction doesn't have an operand, emit the opcode and return. if (instr.Operand == null) { ilGen.Emit(instr.OpCode); return; } // Else (it has an operand)... // If it's a branch instruction, retrieve the corresponding label (to // which we want to jump), emit the instruction and return. if (instr.OpCode.FlowControl == FlowControl.Branch) { ilGen.Emit(instr.OpCode, labels[Int32.Parse(instr.Operand.ToString())]); return; } // Otherwise, simply emit the instruction. I need to use the right // Emit call, so I need to cast the operand to its type. Type operandType = instr.Operand.GetType(); if (typeof(byte).IsAssignableFrom(operandType)) ilGen.Emit(instr.OpCode, (byte) instr.Operand); else if (typeof(double).IsAssignableFrom(operandType)) ilGen.Emit(instr.OpCode, (double) instr.Operand); else if (typeof(float).IsAssignableFrom(operandType)) ilGen.Emit(instr.OpCode, (float) instr.Operand); else if (typeof(int).IsAssignableFrom(operandType)) ilGen.Emit(instr.OpCode, (int) instr.Operand); ... // you get the idea. This is a pretty long method, all like this. } Branch instructions are a special case because instr.Operand is SByte, but Emit expects an operand of type Label. Hence the need for the Dictionary labels. As you can see, this is pretty horrible. What's more, it doesn't work in all cases, for instance with methods that contain try-catch statements, since I haven't emitted them using methods BeginExceptionBlock, BeginCatchBlock, etc, of ILGenerator. This is getting complicated. I guess I can do it: MethodBody has a list of ExceptionHandlingClause that should contain the necessary information to do this. But I don't like this solution anyway, so I'll save this as a last-resort solution. Attempt #3: Go bare-back and just copy the byte array returned by MethodBody.GetILAsByteArray(), since I only want to replace a single instruction for another single instruction of the same size that produces the exact same result: it loads the same type of object on the stack, etc. So there won't be any labels shifting and everything should work exactly the same. I've done this, replacing specific bytes of the array and then calling MethodBuilder.CreateMethodBody(byte[], int), but I still get the same error with exceptions, and I still need to declare the local variables or I'll get an error... even when I simply copy the method's body and don't change anything. So this is more efficient but I still have to take care of the exceptions, etc. Sigh. Here's the implementation of attempt #3, in case anyone is interested: private void TransformMethod(MethodInfo methodInfo, Dictionary<string, MethodInfo[]> dataMembersSafeAccessors, ModuleBuilder moduleBuilder) { ParameterInfo[] paramList = methodInfo.GetParameters(); Type[] args = new Type[paramList.Length]; for (int i = 0; i < args.Length; i++) { args[i] = paramList[i].ParameterType; } MethodBuilder methodBuilder = typeBuilder.DefineMethod( methodInfo.Name, methodInfo.Attributes, methodInfo.ReturnType, args); ILGenerator ilGen = methodBuilder.GetILGenerator(); IList<LocalVariableInfo> locals = methodInfo.GetMethodBody().LocalVariables; foreach (LocalVariableInfo local in locals) { ilGen.DeclareLocal(local.LocalType); } byte[] rawInstructions = methodInfo.GetMethodBody().GetILAsByteArray(); IList<Instruction> instructions = methodInfo.GetInstructions(); int k = 0; foreach (Instruction instr in instructions) { if (instr.OpCode == OpCodes.Ldfld) { MethodInfo safeReadAccessor = dataMembersSafeAccessors[((FieldInfo) instr.Operand).Name][0]; byte[] bytes = toByteArray(OpCodes.Callvirt.Value); for (int m = 0; m < OpCodes.Callvirt.Size; m++) { rawInstructions[k++] = bytes[put.Length - 1 - m]; } bytes = toByteArray(moduleBuilder.GetMethodToken(safeReadAccessor).Token); for (int m = instr.Size - OpCodes.Ldfld.Size - 1; m >= 0; m--) { rawInstructions[k++] = bytes[m]; } } else { k += instr.Size; } } methodBuilder.CreateMethodBody(rawInstructions, rawInstructions.Length); } private static byte[] toByteArray(int intValue) { byte[] intBytes = BitConverter.GetBytes(intValue); if (BitConverter.IsLittleEndian) Array.Reverse(intBytes); return intBytes; } private static byte[] toByteArray(short shortValue) { byte[] intBytes = BitConverter.GetBytes(shortValue); if (BitConverter.IsLittleEndian) Array.Reverse(intBytes); return intBytes; } (I know it isn't pretty. Sorry. I put it quickly together to see if it would work.) I don't have much hope, but can anyone suggest anything better than this? Sorry about the extremely lengthy post, and thanks.

    Read the article

  • WCF events in server-side

    - by Eisenrich
    Hi all, I'm working on an application in WCF and want to receive events in the server side. I have a web that upon request needs to register a fingerprint. The web page request the connection of the device and then every second for 15 seconds requests the answer. The server-side code is apparently "simple" but doesn't work. Here is it: [ServiceContract] interface IEEtest { [OperationContract] void EEDirectConnect(); } class EETest : IEEtest { public void EEDirectConnect() { CZ ee = new CZ(); // initiates the device dll ee.Connect_Net("192.168.1.200", 4011); ee.OnFinger += new _IEEEvents_OnFingerEventHandler(ee_OnFinger); } public void ee_OnFinger() { //here i have a breakpoint; } } every time I put my finger, it should fire the event. in fact if I static void Main() { EETest pp = new EETest(); pp.EEDirectConnect(); } It works fine. but from my proxy it doesn't fire the event. do you have any tips, recommendations, or can you see the error? Thanks everyone.

    Read the article

  • Log4net Logging Problem : Very simple file appender logging not working

    - by contactmatt
    Here's my web.config information <configSections> <section name="log4net" type="log4net.Config.Log4NetConfigurationSectionHandler, log4net"/> </configSections> <log4net> <root> <level value="ALL" /> </root> <appender name="RollingFileAppender" type="log4net.Appender.RollingFileAppender"> <file value="c:\temp\log-file.txt" /> <appendToFile value="true" /> <rollingStyle value="Size" /> <maxSizeRollBackups value="10" /> <maximumFileSize value="1MB" /> <staticLogFileName value="true" /> <layout type="log4net.Layout.SimpleLayout" /> </appender> </log4net> ... Here's the code that initalizes the logger protected void SendMessage() { log4net.Config.XmlConfigurator.Configure(); ILog log = LogManager.GetLogger(typeof(Contact)); ... log.Info("here we go!"); log.Debug("debug afasf"); ... } it doesn't work, no matter what I seem to do. I am referencing the 'log4net.dll' correctly, and by debugging the application i can see that the log object is getting initiated properly. This is a asp.net 3.5 framework web project. Any ideas/suggestions? I thought originally this error may be due to a file write permission constraint, but that doesn't seem to be the case (or so I think).

    Read the article

  • Windows with Plesk Panel installs ActiveState Python 2.5.0 - any thoughts?

    - by B Mahoney
    I expect to run Pylons on a Windows Server 2003 and IIS 6 on a Virtual Private Server (VPS). Most work with the VPS is done through the Plesk 8.6 panel. The Plesk panel has a lot of maintenance advantages for us. However, this Plesk configuration installs ActiveState Python 2.5.0. The Parallels Plesk documents for 8.6 and version 9 insist that only this configuration should be installed. I'm not eager to settle for the baseline 2.5.0. but don't see any safe upgrade path. How has ActiveState Python 2.5.0 been for other users? Can you replace the Parallels\Plesk\Additional\Python with another distribution? I don't want to break Plesk, please. Previously, I followed these instructions, Serving a Pylons app with IIS - Pylons Cookbook Using the default web site IP address, I had Python 2.6.3 installing the ISAPI-WSGI dll in IIS so that I successfully ran Pylons in a virutalenv through IIS using the IP address, no domain name. I would be so happy if I could run this successful configuration for my domains while I must use Plesk. Tips and solutions appreciated.

    Read the article

  • MVC view engine that can render classic ASP?

    - by David Lively
    I'm about to start integrating ASP.NET MVC into an existing 200k+ line classic ASP application. Rewriting the existing code (which runs an entire business, not just the public-facing website) is not an option. The existing ASP 3.0 pages are quite nicely structured (given what was available when this model was put into place nearly 15 years ago), like so: <!--#include virtual="/_lib/user.asp"--> <!--#include virtual="/_lib/db.asp"--> <!--#include virtual="/_lib/stats.asp"--> <!-- #include virtual="/_template/topbar.asp"--> <!-- #include virtual="/_template/lftbar.asp"--> <h1>page name</h1> <p>some content goes here</p> <p>some content goes here</p> <p>.....</p> <h2>Today's Top Forum Posts</h2> <%=forum_top_posts(1)%> <!--#include virtual="/_template/footer.asp"--> ... or somesuch. Some pages will include function and sub definitions, but for the most part these exist in include files. I'm wondering how difficult it would be to write an MVC view engine that could render classic ASP, preferably using the existing ASP.DLL. In that case, I could replace <!--#include virtual="/_lib/user.asp"--> with <%= Html.RenderPartial("lib/user"); %> as I gradually move existing pages from ASP to ASP.NET. Since the existing formatting and library includes are used very extensively, they must be maintained. I'd like to avoid having to maintain two separate versions. I know the ideal way to go about this would be to simply start a new app and say to hell with the ASP code, however, that simply ain't gonna happen. Ideas?

    Read the article

  • Makefile : Build in a separate directory tree

    - by Simone Margaritelli
    My project (an interpreted language) has a standard library composed by multiple files, each of them will be built into an .so dynamic library that the interpreter will load upon user request (with an import directive). Each source file is located into a subdirectory representing its "namespace", for instance : The build process has to create a "build" directory, then when each file is compiling has to create its namespace directory inside the "build" one, for instance, when compiling std/io/network/tcp.cc he run an mkdir command with mkdir -p build/std/io/network The Makefile snippet is : STDSRC=stdlib/std/hashing/md5.cc \ stdlib/std/hashing/crc32.cc \ stdlib/std/hashing/sha1.cc \ stdlib/std/hashing/sha2.cc \ stdlib/std/io/network/http.cc \ stdlib/std/io/network/tcp.cc \ stdlib/std/io/network/smtp.cc \ stdlib/std/io/file.cc \ stdlib/std/io/console.cc \ stdlib/std/io/xml.cc \ stdlib/std/type/reflection.cc \ stdlib/std/type/string.cc \ stdlib/std/type/matrix.cc \ stdlib/std/type/array.cc \ stdlib/std/type/map.cc \ stdlib/std/type/type.cc \ stdlib/std/type/binary.cc \ stdlib/std/encoding.cc \ stdlib/std/os/dll.cc \ stdlib/std/os/time.cc \ stdlib/std/os/threads.cc \ stdlib/std/os/process.cc \ stdlib/std/pcre.cc \ stdlib/std/math.cc STDOBJ=$(STDSRC:.cc=.so) all: stdlib stdlib: $(STDOBJ) .cc.so: mkdir -p `dirname $< | sed -e 's/stdlib/stdlib\/build/'` $(CXX) $< -o `dirname $< | sed -e 's/stdlib/stdlib\/build/'`/`basename $< .cc`.so $(CFLAGS) $(LDFLAGS) I have two questions : 1 - The problem is that the make command, i really don't know why, doesn't check if a file was modified and launch the build process on ALL the files no matter what, so if i need to build only one file, i have to build them all or use the command : make path/to/single/file.so Is there any way to solve this? 2 - Any way to do this in a "cleaner" way without have to distribute all the build directories with sources? Thanks

    Read the article

  • Converting VS2008 Solution to VS2010 Creates compile errors in ASP.NET 3.5 SP1

    - by Lukasz
    I am converting a large solution from Visual Studio 2008 to Visual Studio 2010. The conversion completes without errors. When I go to build the solution one particular section of the application throws error but it didn't when the solution was 2008. Error 1 Could not load file or assembly 'System.Web.DataVisualization, Version=3.5.0.0, Culture=neutral, PublicKeyToken=31bf3856ad364e35' or one of its dependencies. The system cannot find the file specified. C:\MyProject\Results\Result.ascx 3 And C:\CMyProject\Results\Result.ascx(3): Build (web): Could not load file or assembly 'System.Web.DataVisualization, Version=3.5.0.0, Culture=neutral, PublicKeyToken=31bf3856ad364e35' or one of its dependencies. The system cannot find the file specified. The dll is in the bin and it is not in the GAC. The .refresh file is pointing to the correct location. And all sections in the Web.Config are there, if you need to see them let me know. I have gone over the fixes I found online and nothing seems to help. I would really appreciate if someone could help me or point me in the right direction? Thank You.

    Read the article

  • Node.js running under IIS Express Keeps Crashing

    - by PazoozaTest Pazman
    I recently resinstalled Windows 7 on my machine and went back to downloading and installing the tools to help me continue developing node.js windows azure web applications. I followed the instructions given on the node.js azure site: http://www.windowsazure.com/en-us/develop/nodejs/ and using web installer 4.0 it says I have successfully installed these tools: Windows Azure Powershell Windows Azure SDK for Node.js - June 2012 Windows Azure SDK for .Net (VS 2012 RC) - June 2012 IIS Recommend Configuration The problem I am experiencing is that when I run the site using powershell e.g: start-azureemulator -launch it goes ahead and runs IIS Express, and after several minutes IIS Express crashes with the following information: Problem signature: Problem Event Name: APPCRASH Application Name: iisexpress.exe Application Version: 8.0.8298.0 Application Timestamp: 4f620349 Fault Module Name: iiscore.dll Fault Module Version: 8.0.8298.0 Fault Module Timestamp: 4f63b65c Exception Code: c0000005 Exception Offset: 00021767 OS Version: 6.1.7601.2.1.0.256.28 Locale ID: 1033 Additional Information 1: f66d Additional Information 2: f66d807b515d6b2dc6f28f66db769a01 Additional Information 3: 7b2f Additional Information 4: 7b2f6797d07ebc2c23f2b227e779722e I am running 2 instances each time, and both of them crash one after the other. Is anyone experiencing something similar and fix this issue ? Is their an upgrade I need to do ? I've run windows update but it says I've got all the latest updates etc. Can I tell the powershell cmdlet to use IIS 7 instead of IIS Express? I'm guessing its something to do with IIS Express on my machine. I did some hunting around and found this person here who experienced a similar problem: https://github.com/tjanczuk/iisnode/issues/149 I've got a cron job running every 1 second, to check if any website totals need to be updated. Could this be causing IIS Express to crash? Cheers

    Read the article

  • JOAL with JNLPAppletLauncher Problem

    - by user347445
    Hi, I am developing a Java Applet that makes use of JOAL. In order to avoid annoying dialogues I wanted to load JOAL with the JNLPAppletLauncher as it is shown on https://jogl-demos.dev.java.net/applettest-joal.html Unfortunately with this approach I get this exception: JNLPAppletLauncher.loadLibrary("joal_native") loading: C:\Users\Barbara\AppData\Local\Temp\jnlp-applet\jln7379734545861869319\jln1640167325490042232\joal_native.dll Exception in thread "AWT-EventQueue-2" java.lang.RuntimeException: Can not get proc address for method "alcCaptureCloseDevice": Couldn't set value of field "_addressof_alcCaptureCloseDevice" in class net.java.games.joal.impl.ALCProcAddressTable at com.sun.gluegen.runtime.ProcAddressHelper.resetProcAddressTable(ProcAddressHelper.java:113) at net.java.games.joal.impl.ALProcAddressLookup.resetALCProcAddressTable(ALProcAddressLookup.java:109) at net.java.games.joal.impl.ALCImpl.alcOpenDevice(ALCImpl.java:341) at net.java.games.joal.util.ALut.alutInit(ALut.java:69) at demos.devmaster.lesson1.SingleStaticSource.initialize(SingleStaticSource.java:194) at demos.devmaster.lesson1.SingleStaticSource.access$000(SingleStaticSource.java:57) at demos.devmaster.lesson1.SingleStaticSource$1.actionPerformed(SingleStaticSource.java:79) at javax.swing.AbstractButton.fireActionPerformed(Unknown Source) at javax.swing.AbstractButton$Handler.actionPerformed(Unknown Source) at javax.swing.DefaultButtonModel.fireActionPerformed(Unknown Source) at javax.swing.DefaultButtonModel.setPressed(Unknown Source) at javax.swing.plaf.basic.BasicButtonListener.mouseReleased(Unknown Source) at java.awt.Component.processMouseEvent(Unknown Source) at javax.swing.JComponent.processMouseEvent(Unknown Source) at java.awt.Component.processEvent(Unknown Source) at java.awt.Container.processEvent(Unknown Source) at java.awt.Component.dispatchEventImpl(Unknown Source) at java.awt.Container.dispatchEventImpl(Unknown Source) at java.awt.Component.dispatchEvent(Unknown Source) at java.awt.LightweightDispatcher.retargetMouseEvent(Unknown Source) at java.awt.LightweightDispatcher.processMouseEvent(Unknown Source) at java.awt.LightweightDispatcher.dispatchEvent(Unknown Source) at java.awt.Container.dispatchEventImpl(Unknown Source) at java.awt.Component.dispatchEvent(Unknown Source) at java.awt.EventQueue.dispatchEvent(Unknown Source) at java.awt.EventDispatchThread.pumpOneEventForFilters(Unknown Source) at java.awt.EventDispatchThread.pumpEventsForFilter(Unknown Source) at java.awt.EventDispatchThread.pumpEventsForHierarchy(Unknown Source) at java.awt.EventDispatchThread.pumpEvents(Unknown Source) at java.awt.EventDispatchThread.pumpEvents(Unknown Source) at java.awt.EventDispatchThread.run(Unknown Source) Caused by: java.lang.RuntimeException: Unable to find and load OpenAL library at net.java.games.joal.impl.ALProcAddressLookup$DynamicLookup.dynamicLookupFunction(ALProcAddressLookup.java:66) at com.sun.gluegen.runtime.ProcAddressHelper.resetProcAddressTable(ProcAddressHelper.java:106) ... 30 more I am using Firefox 3.6.3, Java 1.6._017 and am on a Windows 7 Machine. I also tried this on another computer with Windows XP and on one with Linux, always with the same result, so it does not seem to be specific for my computer. I also get the same result for IE8. Any ideas how I could fix this? Thank you very much.

    Read the article

  • Windows Media Encoder object not created in ASP.NET on MS Server 2003 64 bit

    - by Ron
    Hello, I created (and used) a Windows Media Encoder object in Microsoft Visual C# 2008 Express Edition on MS Server 2003 64 bit. This worked fine. However, when I attempted to create the equivalent Windows Media Encoder object using Microsoft Visual Web Developer 2008 on MS Server 2003 64 bit, the following exception was thrown: "Retrieving the COM class factory for component with CLSID {632B606A-BBC6-11D2-A329-006097C4E476} failed due to the following error: 80040154." It cannot be that the component isn’t registered, because both have a reference to the same WMEncEng.dll file. The Microsoft Visual Web Developer 2008 code also worked fine on XP 32 bit. Could it be a problem with permissions? Regardless, anyone have any ideas why this problem is occurring and, more importantly, how to resolve it? Thank you. Here are the two code snippets from MS Server 2003 64 bit: Microsoft Visual Web Developer 2008 (did not work): using System; using WMEncoderLib; namespace TestWMEnc { public partial class _Default : System.Web.UI.Page { protected void Page_Load(object sender, EventArgs e) { try { WMEncoder encoder = new WMEncoder(); //exception thrown // ... } catch (Exception err) { string exception = err.Message; } } } } Microsoft Visual C# 2008 Express Edition (worked fine): using System; using System.Windows.Forms; using WMEncoderLib; namespace testWMEncoder { public partial class Form1 : Form { public Form1() { InitializeComponent(); } private void button1_Click(object sender, EventArgs e) { try { WMEncoder encoder = new WMEncoder(); // ... } catch (Exception err) { string exception = err.Message; } } } }

    Read the article

  • How do I lock the workstation from a windows service?

    - by Brad Mathews
    Hello, I need to lock the workstation from a windows service written in VB.Net. I am writing the app on Windows 7 but it needs to work under Vista and XP as well. User32 API LockWorkStation does not work as it requires an interactive desktop and I get return value of 0. I tried calling %windir%\System32\rundll32.exe user32.dll,LockWorkStation from both a Process and from Shell, but still nothing happens. Setting the service to interact with the desktop is a no-go as I am running the service under the admin account so it can do some other stuff that requires admin rights - like disabling the network, and you can only select the interact with desktop option if running under Local System Account. That would be secondary question - how to run another app with admin rights from a service running under Local System Account without bugging the user. I am writing an app to control my kids computer/internet access (which I plan to open source when done) so I need everything to happen as stealthily as possible. I have a UI that handles settings and status notifications in the taskbar, but that is easy to kill and thus defeat the locking. I could make another hidden Windows Forms app to handle the locking, but that just seems a rather inelegant solution. Better ideas anyone? Thanks! Brad

    Read the article

  • Are there size limitations to the .NET Assembly format?

    - by McKAMEY
    We ran into an interesting issue that I've not experienced before. We have a large scale production ASP.NET 3.5 SP1 Web App Project in Visual Studio 2008 SP1 which gets compiled and deployed using a Website Deployment Project. Everything has worked fine for the last year, until after a check-in yesterday the app started critically failing with BadImageFormatException. The check-in in question doesn't change anything particularly special and the errors are coming from areas of the app not even changed. Using Reflector we inspected the offending methods to find that there were garbage strings in the code (which .NET Reflector humorously interpreted as Chinese characters). We have consistently reproduced this on several machines so it does not appear to be hardware related. Further inspection showed that those garbage strings did not exist in the Assemblies used as inputs to aspnet_merge.exe during deployment. aspnet_merge.exe / Web Deployment Project Output Assemblies Properties: Merge all outputs to a single assembly Merge each individual folder output to its own assembly Merge all pages and control outputs to a single assembly Create a separate assembly for each page and control output In the web deployment project properties if we set the merge options to the first option ("Merge all outputs to a single assembly") we experience the issue, yet all of the other options work perfectly! My question: does anyone know why this is happening? Is there a size-limit to aspnet_merge.exe's capabilities (the resulting merged DLL is around 19.3 MB)? Are there any other known issues with merging the output of WAPs? I would love it if any Assembly format / aspnet_merge.exe gurus know about any such limitations like this. Seems to me like a 25MB Assembly, while big, isn't outrageous.

    Read the article

  • ASP.NET MVC View Engine Resolution Sequence

    - by intangible02
    I created a simple ASP.NET MVC version 1.0 application. I have a ProductController which has one action Index. In the view, I created a corresponding Index.aspx under Product subfolder. Then I referenced the Spark dll and created Index.spark under the same Product view folder. The Application_Start looks like protected void Application_Start() { RegisterRoutes(RouteTable.Routes); ViewEngines.Engines.Clear(); ViewEngines.Engines.Add(new Spark.Web.Mvc.SparkViewFactory()); ViewEngines.Engines.Add(new WebFormViewEngine()); } My expectation is that since the Spark engine registers before default WebFormViewEngine, when browse the Index action in Product controller, the Spark engine should be used, and WebFormViewEngine should be used for all other urls. However, the test shows that the Index action for Product controller also uses the WebFormViewEngine. If I comment out the registration of WebFormViewEnginer (the last line in the code), I can see that the Index action is rendered by Spark engine and the rest urls generates an error (since the defualt engine is gone), it proves that all my Spark code is correct. Now my question is how the view engine is resolved? Why the registration sequence does not take effect?

    Read the article

  • software distribution and patch management

    - by daemonkid
    How do software houses like Microsoft or anti-virus companies patch/update their software? Anti virus companies dont send the complete executable; only new virus signatures I suppose. Similarly, Ive noticed microsoft sends certain files to the '$NtUninstallKB......$' folder that it creates when it the windows update program runs. I suppose there is an installer in each such folder there that replaces only those dlls that need to be updated or fixed. Questions Is there a universal method for doing this or does each house employ their own methods? I dont want to re-send the entire application to each individual client. Suppose if only certain dlls need to be changed or maybe some more added, how should I go about planning my final compiled application. Do I need to look at separating my application into multiple assemblies? If yes, then is there some compilation method that is allows to pack specific classes into a particular dll? What I have put down here are my thoughts on the subject and I could be wrong. Could anyone throw some light on this please? I am looking at implementing such a deployment and patch management technique for the .net platform. Thanks for your time.

    Read the article

  • How do I setup NInject? (I'm getting can't resolve "Bind", in the line "Bind<IWeapon>().To<Sword>()

    - by Greg
    Hi, I'm getting confused in the doco how I should be setting up Ninject. I'm seeing different ways of doing it, some v2 versus v1 confusion probably included... Question - What is the best way in my WinForms application to set things up for NInject (i.e. what are the few lines of code required). I'm assuming this would go into the MainForm Load method. In other words what code do I have to have prior to getting to: Bind<IWeapon>().To<Sword>(); I have the following code, so effectively I just want to get clarification on the setup and bind code that would be required in my MainForm.Load() to end up with a concrete Samurai instance? internal interface IWeapon { void Hit(string target); } class Sword : IWeapon { public void Hit(string target) { Console.WriteLine("Chopped {0} clean in half", target); } } class Samurai { private IWeapon _weapon; [Inject] public Samurai(IWeapon weapon) { _weapon = weapon; } public void Attack(string target) { _weapon.Hit(target); } } thanks PS. I've tried the following code, however I can't resolve the "Bind". Where does this come from? what DLL or "using" statement would I be missing? private void MainForm_Load(object sender, EventArgs e) { Bind<IWeapon>().To<Sword>(); // <== *** CAN NOT RESOLVE Bind *** IKernel kernel = new StandardKernel(); var samurai = kernel.Get<Samurai>();

    Read the article

  • Disassembling with python - no easy solution?

    - by Abc4599
    Hi, I'm trying to create a python script that will disassemble a binary (a Windows exe to be precise) and analyze its code. I need the ability to take a certain buffer, and extract some sort of struct containing information about the instructions in it. I've worked with libdisasm in C before, and I found it's interface quite intuitive and comfortable. The problem is, its Python interface is available only through SWIG, and I can't get it to compile properly under Windows. At the availability aspect, diStorm provides a nice out-of-the-box interface, but it provides only the Mnemonic of each instruction, and not a binary struct with enumerations defining instruction type and what not. This is quite uncomfortable for my purpose, and will require a lot of what I see as spent time wrapping the interface to make it fit my needs. I've also looked at BeaEngine, which does in fact provide the output I need, a struct with binary info concerning each instruction, but its interface is really odd and counter-intuitive, and it crashes pretty much instantly when provided with wrong arguments. The CTypes sort of ultimate-death-to-your-python crashes. So, I'd be happy to hear about other solutions, which are a little less time consuming than messing around with djgcc or mingw to make SWIGed libdisasm, or writing an OOP wrapper for diStorm. If anyone has some guidance as to how to compile SWIGed libdisasm, or better yet, a compiled binary (pyd or dll+py), I'd love to hear/have it. :) Thanks ahead.

    Read the article

  • Assembly installed into the GAC not showing up in Visual Studio

    - by yodaj007
    This sounds related to this question, but they aren't the same thing. That question had no assemblies showing up. Mine has everything except the specific one I installed. I'm hoping someone has a solution to this... am I doing something wrong? Or did I find some bug in VS? I am using Visual Studio 2010 Professional Beta 2 on Windows 7 Ultimate. I just downloaded Rhino Mocks and decided to install it into the GAC using the command-line utility GACUTIL. I then rebooted. Here you can see the assembly in my GAC (click to enlarge): And here is the list of assemblies available to me in Visual Studio: Here is the command prompt where I installed it, and then confirmed it: C:\Users\jason\Downloads>gacutil -i Rhino.Mocks.dll Microsoft (R) .NET Global Assembly Cache Utility. Version 4.0.21006.1 Copyright (c) Microsoft Corporation. All rights reserved. Assembly successfully added to the cache C:\Users\jason\Downloads>gacutil /l |grep -i rhino Rhino.Mocks, Version=3.6.0.0, Culture=neutral, PublicKeyToken=0b3305902db7183f, processorArchitecture=MSIL

    Read the article

  • wamp cannot load mysqli extension

    - by localhost
    WAMP installed fine, no problems, BUT... When going to phpMyAdmin, I get the error from phpMyAdmin as follows: "Cannot load mysqli extension. Please check your PHP configuration". Also, phpMyAdmin documentation explains this error message as follows: "To connect to a MySQL server, PHP needs a set of MySQL functions called "MySQL extension". This extension may be part of the PHP distribution (compiled-in), otherwise it needs to be loaded dynamically. Its name is probably mysql.so or php_mysql.dll. phpMyAdmin tried to load the extension but failed. Usually, the problem is solved by installing a software package called "PHP-MySQL" or something similar." Finally, the apache_error.log file has the following PHP warnings (see the mySQL warning): PHP Warning: Zend Optimizer does not support this version of PHP - please upgrade to the latest version of Zend Optimizer in Unknown on line 0 PHP Warning: Zend Platform does not support this version of PHP - please upgrade to the latest version of Zend Platform in Unknown on line 0 PHP Warning: Zend Debug Server does not support this version of PHP - please upgrade to the latest version of Zend Debug Server in Unknown on line 0 PHP Warning: gd wrapper does not support this version of PHP - please upgrade to the latest version of gd wrapper in Unknown on line 0 PHP Warning: java wrapper does not support this version of PHP - please upgrade to the latest version of java wrapper in Unknown on line 0 PHP Warning: mysql wrapper does not support this version of PHP - please upgrade to the latest version of mysql wrapper in Unknown on line 0 So, for some reason PHP is not recognizing the mysql extension. Anyone know why? Any solution or workaround?

    Read the article

  • Adding editFTPnetPRO to SSIS package causes error message

    - by gfrizzle
    I'm trying to add some secure FTP code to an SSIS package. I've used the EnterpriseDT product successfully on other .NET projects, so I wanted to incorporate it into an SSIS 2008 package I'm working on. If I create a Script Task (VB), edit the script, choose Project | Add Reference, and select the editFTPnetPRO.dll file, it comes back with this error: No template information found. See the application log in Event Viewer for more details. To open Event Viewer, click Start, click Control Panel, double-click Administrative Tools, and then double-click Event Viewer. The application log doesn't contain any pertinent details. I have no idea what this is trying to tell me. I've gone down a couple dead ends searching for this error message and following the prescribed fixes, but nothing has fixed it yet. Any idea what might be going wrong? P.S. - I tried the devenv.exe /installvstemplates fix, which didn't change anything. Update: Here is the error captured in the SSIS package when you try to run it: Error: System.Reflection.TargetInvocationException: Exception has been thrown by the target of an invocation. --- System.IO.FileNotFoundException: Could not load file or assembly 'edtFTPnetPRO, Version=6.3.1.20, Culture=neutral, PublicKeyToken=0dce1ad63760d80b' or one of its dependencies. The system cannot find the file specified. Where is it looking for this file? I tried copying it to the project direcory, the bin folder, and the C:\WINDOWS\Microsoft.NET\Framework\v2.0.nnnn folder, but it still can't find it, and it won't tell me where it's looking.

    Read the article

< Previous Page | 221 222 223 224 225 226 227 228 229 230 231 232  | Next Page >