Search Results

Search found 6530 results on 262 pages for 'sqlpackage exe'.

Page 230/262 | < Previous Page | 226 227 228 229 230 231 232 233 234 235 236 237  | Next Page >

  • Windows Service doesn't start process with different credentials

    - by Marcus
    I have a Windows Service, running as a user, that should start several processes under different user credentials. I'm using the following code to start a process: Dim winProcess As New System.Diagnostics.Process With winProcess .StartInfo.Arguments = "some_args" .StartInfo.CreateNoWindow = True .StartInfo.ErrorDialog = False .StartInfo.FileName = "C:\TEMP\ProcessFromService\ProcessFromService\bin\Debug\ProcessFromService.exe" .StartInfo.UseShellExecute = False .StartInfo.WindowStyle = ProcessWindowStyle.Hidden 'Opgave WorkingDirectory kan soms tot problemen leiden, indien betreffende directory 'niet bereikbaar (rechten) is voor opgegeven gebruiker. 'Beter dus om deze niet op te geven. '.StartInfo.WorkingDirectory = My.Computer.FileSystem.SpecialDirectories.Temp .StartInfo.Domain = "" .StartInfo.UserName = "MyUserId" Dim strPassword As String = "MyPassword" Dim ssPassword As New Security.SecureString For Each chrPassword As Char In strPassword.ToCharArray ssPassword.AppendChar(chrPassword) Next .StartInfo.Password = ssPassword .Start() End With The process is correctly started when I use the same credentials as of which the Windows Service is running under. The process is not started, without any error, when I use different credentials. In other words: If the Windows Service is running as UserA then I can start a process running as UserA. If the Windows Service is running as UserB then I can not start a process running as UserA. I have created a test project in which I can reproduce this problem. If you put this project in C:\Temp then the used paths will be correct. You can download this test project here: https://dl.dropboxusercontent.com/u/5391091/ProcessFromService.zip NB: I hope this info is enough to explain it. If you need more info, please let me know and I will add it.

    Read the article

  • Read attributes of MSBuild custom tasks via events in the Logger

    - by gt
    I am trying to write a MSBuild logger module which logs information when receiving TaskStarted events about the Task and its parameters. The build is run with the command: MSBuild.exe /logger:MyLogger.dll build.xml Within the build.xml is a sequence of tasks, most of which have been custom written to compile a (C++ or C#) solution, and are accessed with the following custom Task: <DoCompile Desc="Building MyProject 1" Param1="$(Param1Value)" /> <DoCompile Desc="Building MyProject 2" Param1="$(Param1Value)" /> <!-- etc --> The custom build task DoCompile is defined as: public class DoCompile : Microsoft.Build.Utilities.Task { [Required] public string Description { set { _description = value; } } // ... more code here ... } Whilst the build is running, as each task starts, the logger module receives IEventSource.TaskStarted events, subscribed to as follows: public class MyLogger : Microsoft.Build.Utilities.Logger { public override void Initialize(Microsoft.Build.Framework.IEventSource eventSource) { eventSource.TaskStarted += taskStarted; } private void taskStarted(object sender, Microsoft.Build.Framework.TaskStartedEventArgs e) { // write e.TaskName, attributes and e.Timestamp to log file } } The problem I have is that in the taskStarted() method above, I want to be able to access the attributes of the task for which the event was fired. I only have access to the logger code and cannot change either the build.xml or the custom build tasks. Can anyone suggest a way I can do this?

    Read the article

  • python: help defining/installing simple script to setup machine-specific information

    - by Jason S
    (This is related to scons but I think most of the following should be fairly general to python) I would like to define a python file/library that I put in a Well-Known Place somewhere on my computer that I can use to define machine-specific paths, and was looking for help on how to do this well, since I'm a beginner to Python & really only use it for my scons work. scons uses a SConstruct file which can execute python code. What I would like to do is something like this: My SConstruct file would contain this at the beginning: defaultEnv = JJJJJ.getMachineSpecificPaths() or (do both of these syntaxes work?) import JJJJJ defaultEnv = getMachineSpecificPaths() I define a JJJJJ.py file somewhere installed in the python dir which contains the following def getMachineSpecificPaths(): ... does something here, I don't know what ... that reads a file machine-specific-paths.txt (maybe it has the code Ross Rogers mentioned in my other question) located in the same directory as JJJJJ.py containing the following: machine-specific-paths.txt TI_C28_ROOT C:/appl/ti/ccs/?4.1.1/ccsv4/tools/co?mpiler/c2000 JSDB c:/bin/jsdb/jsdb.exe PYTHON_PATH c:/appl/python/2.6.4 The thing is, I don't really know much about the conventions in Python about where you put system-wide libraries and files. This is probably really simple to get right but I don't know how.

    Read the article

  • Naming multi-instance performance counters in .NET

    - by Roger Lipscombe
    Most multiple instance performance counters in Windows seem to automatically(?) have a #n on the end if there's more than one instance with the same name. For example: if, in Perfmon, you look under the Process category, you'll see: ... dwm explorer explorer#1 ... I have two explorer.exe processes, so the second counter has #1 appended to its name. When I attempt to do this in a .NET application: I can create the category, and register the instance (using the PerformanceCounterCategory.Create that takes a CounterCreationDataCollection). I can open the counter for write and write to it. When I open the counter a second time, it opens the same counter. This means that I have two applications fighting over the counters. The documentation for PerformanceCounter.InstanceName states that # is not allowed in the name. So: how do I have multiple-instance performance counters that are actually multiple instance? And where the second (and subsequent) instances get #n appended to the name? That is: I know that I can put the process ID (e.g.) on the instance name. This works, but has the unfortunate side effect that restarting the process results in a new PID, and Perfmon continues monitoring the old counter.

    Read the article

  • Windows 7 dsound.dll load from dll crash

    - by Jonas Byström
    I'm getting a crash when loading dsound.dll from another DLL in Windows 7. The following code crashes: #include <Windows.h> #include <mmreg.h> #include <dsound.h> #include <assert.h> HRESULT (WINAPI *pDirectSoundEnumerateA)(LPDSENUMCALLBACKA pDSEnumCallback, LPVOID pContext); HMODULE hDsound; BOOL CALLBACK DSEnum(LPGUID a, LPCSTR b, LPCSTR c, LPVOID d) { return TRUE; } void CrashTest() { HRESULT hr; hDsound = LoadLibraryA("dsound.dll"); assert(hDsound); *(void**)&pDirectSoundEnumerateA = (void*)GetProcAddress(hDsound, "DirectSoundEnumerateA"); assert(pDirectSoundEnumerateA); hr = pDirectSoundEnumerateA(DSEnum, NULL); assert(!FAILED(hr)); } BOOL APIENTRY DllMain(HANDLE hModule,DWORD ul_reason_for_call,LPVOID lpReserved) { if (ul_reason_for_call == DLL_PROCESS_ATTACH) { DisableThreadLibraryCalls(hModule); CrashTest(); } } with this error code: Unhandled exception at ... in ...: 0xC0000005: Access violation reading location 0x00000044. (it's always 0x44 for some reason). It works on Windows XP or when loading directly from the .exe (not from a separate DLL). Help!?! :)

    Read the article

  • C# app running as either Windows Form or as Console Application

    - by Aeolien
    I am looking to have one of my Windows Forms applications be run programmatically—from the command line. In preparation, I have separated the logic in its own class from the Form. Now I am stuck trying to get the application to switch back and forth based on the presence of command line arguments. Here is the code for the main class: static class Program { /// <summary> /// The main entry point for the application. /// </summary> [STAThread] static void Main() { string[] args = Environment.GetCommandLineArgs(); if (args.Length > 1) // gets passed its path, by default { CommandLineWork(args); return; } Application.EnableVisualStyles(); Application.SetCompatibleTextRenderingDefault(false); Application.Run(new Form1()); } private static void CommandLineWork(string[] args) { Console.WriteLine("It works!"); Console.ReadLine(); } where Form1 is my form and the It works! string is just a placeholder for the actual logic. Right now, when running this from within Visual Studio (with command line arguments), the phrase It works! is printed to the Output. However, when running the /bin/Debug/Program.exe file (or /Release for that matter) the application crashes. Am I going about this the right way? Would it make more sense (i.e. take less developer time) to have my logic class be a DLL that gets loaded by two separate applications? Or is there something entirely different that I'm not aware of? Thanks in advance!

    Read the article

  • How to deploy ClickOnce .Net 3.5 application on 3.0 machine

    - by Buthrakaur
    I have .Net 3.5 SP1 WPF application which I'm successfully deploying to client computers using ClickOnce. Now I got new requirement - one of our clients need to run the application on machines equipped just with .Net 3.0 and it's entirely impossible to upgrade or install anything on the machines. I already tried to run the 3.5 application with some of the 3.5FW DLLs copied to the application directory and it worked without any problems. The only problem at the moment is ClickOnce. I already made it to include the 3.5FW System.*.dll files in list of application files, but it always aborts installation on 3.0 machine with this error message: Unable to install or run the application. The application requires that assembly System.Core Version 3.5.0.0 be installed in the Global Assembly Cache (GAC) first. Please contact your system administrator. I already tried to tweak prerequisites on Publish tab of my project, but no combination solved the issue. What part of ClickOnce is responsible for checking prerequisites? I already tried to deploy using mageui.exe, but the 3.5FW error is still present. What should I do to fore ClickOnce to stop checking any prerequisites at all? The project is created using VS2010.

    Read the article

  • How can I automatically elevate a COM interface used for automation?

    - by Jim Flood
    I have a Windows service built with ATL to expose a LocalServer32 COM interface for a set of admin commands used for configuring the service, and these can be used from VBScript for example: Set myObj = WScript.CreateObject("MySvc.Administrator") myObj.DoSomething() I want DoSomething to run elevated, and I would like the UAC prompt to come up automatically when this is called by the VBScript. Is this possible? I know I can run the script in an elevated command shell, and that I can use objShell.ShellExecute WScript.FullName, Chr(34) & WScript.ScriptFullName & Chr(34), vbNullString, "runas" for example, to run the VBScript itself elevated, and either of those work fine -- the COM method finds itself elevated. However, AFAIK getting an elevated Explorer window on the desktop is convoluted (it's not as simple as right-clicking Start/Accessories/Windows Explorer/Run as Administrator, which doesn't actually elevate.) I want a user in the local admin group to be able to drag-and-drop files and folders onto the script, and then have the script call the admin COM interface with those pathnames as arguments. (And I am hoping for something simpler than monkeying around with the args and using ShellExecute "runas".) I've tried setting UAC Execution Level to requireAdministrator in the service EXE's manifest, and setting Elevated/Enabled = 1 and LocalizedString in the registry for the MySvc.Administrator class, and these don't do the trick.

    Read the article

  • Compiling gstreamer plugin in windows

    - by utnapistim
    Hello all, My question: What is the correct way to compile a gstreamer plugin in windows, so that it will be accepted by gstreamer (actually Songbird on top of gstreamer). My setup: I have downloaded the songbird sources following the steps described here and I have a trunk/dependencies/windows-i686-msvc8 directory within my svn sources with all the gstreamer binaries. I have created a gstreamer empty plugin skeleton following the steps detailed in the GStreamer Plugin Writer's Guide, and compiled it against the gstreamer binaries in the Songbird dependencies folder. The compilation was done with VS2010 RC1 (Visual Studio 2008 yelded the same results), using an empty DLL project with the .h and .c files generated using the GStreamer Plugin Writer's Guide. The DLL was lined with libcpmt.lib, libcmt.lib, ws2_32.lib, gobject-2.0.lib, gthread-2.0.lib, gstreamer-0.10-0.lib, glib-2.0.lib, kernel32.lib, nspr4.lib and ignoring all default libraries. I have compiled the files as both .c and .cpp with the same results. Testing: I have installed the Songbird binaries corresponding to the correct svn version, then installed Songbird Developer Tools addon and used it to create an addon for testing my gstreamer plugin. Songbird will not load the pluggin. I have also tried to load it with gst-launch.exe from the trunk/dependencies/windows-i686-msvc8/[...] directory and that generated runtime error R6034: An application has made an attempt to load the C runtime library incorrectly. Most resources I found for this problem recommended restarting or reinstalling windows :(.

    Read the article

  • Delphi Client-Server Application using Firebird 2.5 embedded connection error

    - by Japster
    0 down vote favorite 1 share [fb] share [tw] I have got a lengthy question to ask. First of all Im still very new when it comes to Delphi programming and my experience has beem mostly developing small single user database applications using ADO and an Access database. I need to take the transition now to a client server application and this is where the problem starts. I decided to use Firebird 2.5 embeded as my database, as it is open source, and it is can be used with the interbase components in Delphi and that multiple clients can access the database simultanously. So I followed the interbase tutorial in Delphi. I managed to connect the client to the server and see the data in the example (While both are running on my pc), but when i tried to move the client to another pc, keeping the server on mine and running it to see if I can connect to the server it gave me the following error. Exception EIdSocketError in module clientDemo.exe at 0029DCAC. Socket Error # 10061 Connection refused. I understand that this might be because the host is defined as localhost in the client. But here is my first question. In the TSQLConncetion you can set die hostname under Driver-Hostname. The thing I want to know is how do you do this at run time, as I cannot get the property when I try and make an edit box to allow the user to enter the value and then set it via code like for example: SQLConncetion1.Driver.Hostname := edtHost.text; This cannot be done this way and the only way I see you can set the hostname is with the object inspector, but that is not available at runtime and I need to set the hostname on the client when the program is running the first time, so how do you set the hostname/IP address at runtime? Im using Delphi XE2 There is still a lot of questions to come especially when it comes to deployment, but I will take this piece by piece and I appreciate the advice.

    Read the article

  • Saving Abstract and Sub classes to database

    - by bretddog
    Hi, I have an abstract class "StrategyBase", and a set of sub classes, StrategyA/B/C etc. The sub classes use some of the properties of the base class, and have some individual properties. My question is how to save this to a database. I'm currently using SqlCE, and Linq-To-Sql by creating entity classes automatically with SqlMetal.exe. I've seen there are three solutions shown in this question, but I'm not able to see how these solutions will work or not with SqlMetal/entity classes. Though it seems to me the "concrete table inheritance" would probably work without any manual modifying. What about the other two, would they be problematic? For "Single Table Inheritance" wouldn't all classes get all variables, even though they don't need them? And for the "Class table inheritance" solution I can't really see at all how that will map into the entity-classes for a useful purpose. I may note that I extend these partial entity classes for making the classes of my business objects. I may also consider moving to EntityFramework instead of SqlMetal/Linq2Sql, so would be nice also to know if that makes any difference to what schema is easy to implement. One likely important thing to note is that I will constantly be develop new strategies, which makes me have to modify the program code, and probably the database shcema; when adding a new strategy. Sorry the question is a bit "all over the place", but hopefully it's some clear advantages/disadvantages here that you may be able to advice. ? Cheers!

    Read the article

  • SharpDevelop WIX project: MSBuild Configurations

    - by chezy525
    Using SharpDevelop, I wrote a windows service with a WIX setup project to install/auto-start it. For testing purposes, I've done a number of things I don't want to do in the release version (i.e. add an uninstall shortcut to the desktop). So, my question really boils down to this; how do you handle build configurations within a WiX project? I think I've solved most of my problems after I found this question Passing build parameters to .wxs file to dynamicaly build wix installers. And thus far I've done the following: Added a property that checks the Configuration variable <Product> ... <Property Id="DEBUG">$(var.Configuration) == 'Debug'</Property> ... Separated all of the debug files into unique components and setup as a separate feature with a condition checking the DEBUG property. <Product> ... <Feature> ... <Feature Id="DebugFiles" Level="1"> <ComponentRef Id="UninstallShortcutComponent" /> <Condition Level="0">DEBUG</Condition> </Feature> ... Then, finally, pointing to the correct file based on the configuration, using the Configuration variable <Directory> ... <Component> <File Source="..\mainProject\bin\$(var.Configuration)\main.exe" /> </Component> ... So, now my question is simplified to how to handle files that may not exist under certain build configurations (like .pdb files). Using all of the above (including pointing the file source to the ...\bin\Release\*.pdb, which I know isn't expected to exist) I get a LGHT0103 compiler error, it can't find the file.

    Read the article

  • Save XML directly to Database with C#

    - by LifeH2O
    Here is a part of my xml file <teams> <team-profile> <name>Australia</name> <id>1</id> <stats type="Test"> <span>1877-2010</span> <matches>721</matches> <won>339</won> <lost>186</lost> <tied>2</tied> <draw>194</draw> <percentage>47.01</percentage> </stats> <squad> <player id="135" fullname="Shane Warne"/> <player id="136" fullname="Damien Martyn"/> <player id="138" fullname="Michael Clarke"/> </squad> </team-profile> </team> I have read somewhere that there is a way to save this XML directly to database. I am using VS2010. I have created the dataset, for the data i need from this xml. Is there any way to map this XML directly on dataset? Any other idea? I also have to save some other more complex XML files to database. I have tried xsd.exe to create xsd schema for this XML.

    Read the article

  • Unity Configuration and Same Assembly

    - by tyndall
    I'm currently getting an error trying to resolve my IDataAccess class. The value of the property 'type' cannot be parsed. The error is: Could not load file or assembly 'TestProject' or one of its dependencies. The system cannot find the file specified. (C:\Source\TestIoC\src\TestIoC\TestProject\bin\Debug\TestProject.vshost.exe.config line 14) This is inside a WPF Application project. What is the correct syntax to refer to the Assembly you are currently in? is there a way to do this? I know in a larger solution I would be pulling Types from seperate assemblies so this might not be an issue. But what is the right way to do this for a small self-contained test project. Note: I'm only interested in doing the XML config at this time, not the C# (in code) config. UPDATE: see all comments My XML config: <configuration> <configSections> <section name="unity" type="Microsoft.Practices.Unity.Configuration.UnityConfigurationSection, Microsoft.Practices.Unity.Configuration" /> </configSections> <unity> <typeAliases> <!-- Lifetime manager types --> <typeAlias alias="singleton" type="Microsoft.Practices.Unity.ContainerControlledLifetimeManager, Microsoft.Practices.Unity" /> <typeAlias alias="external" type="Microsoft.Practices.Unity.ExternallyControlledLifetimeManager, Microsoft.Practices.Unity" /> <typeAlias alias="IDataAccess" type="TestProject.IDataAccess, TestProject" /> <typeAlias alias="DataAccess" type="TestProject.DataAccess, TestProject" /> </typeAliases> <containers> <container name="Services"> <types> <type type="IDataAccess" mapTo="DataAccess" /> </types> </container> </containers> </unity> </configuration>

    Read the article

  • Why does a simple ApplicationSetting PropertyBinding for a Form does not work in C#?

    - by Mike Rosenblum
    My question involves this simple walkthrough shown in the article Preserve Size and Location of Windows Forms – Part I by Dennis Wallentin. This approach works 100% fine when using VB.NET. When using the same steps in C#, however, the settings within the Settings tab of the application's properties looks correct, and the app.config file looks right, but the values are not saved when you run it. The app.config file winds up looking like this: <?xml version="1.0" encoding="utf-8" ?> <configuration> <configSections> <sectionGroup name="userSettings" type="System.Configuration.UserSettingsGroup, System, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089" > <section name="WindowsAppCs.Properties.Settings" type="System.Configuration.ClientSettingsSection, System, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089" allowExeDefinition="MachineToLocalUser" requirePermission="false" /> </sectionGroup> </configSections> <userSettings> <WindowsAppCs.Properties.Settings> <setting name="Location" serializeAs="String"> <value>0, 0</value> </setting> <setting name="Size" serializeAs="String"> <value>284, 262</value> </setting> </WindowsAppCs.Properties.Settings> </userSettings> </configuration> It looks right to me, but the values do not update when running hosted within Visual Studio or when running the compiled EXE. I am sure that something very simple needs to be added or done, but I don't know what. Does anyone have any ideas here? Much thanks in advance...

    Read the article

  • Null Pointer Exception in Primavera P6 8.1

    - by gwrichard
    I am getting a null pointer exception in a Primavera P6 8.1 installation. The exception only occurs in one section of the web-client: Application settings.P6 web and the P6 API are deployed on the same WebLogic (10.3.5) node running on a Windows Server 2008 R2 installation. I have done this installation using this same software stack a dozen times and don't have this issue on any of the other installs. Exact error below: Match: beginTraversal Match: digest selected JREDesc: JREDesc[version 1.6.0_20+, heap=-1--1, args=null, href=http://java.sun.com/products/autodl/j2se, sel=false, null, null], JREInfo: JREInfo for index 0: platform is: 1.7 product is: 1.7.0_17 location is: http://java.sun.com/products/autodl/j2se path is: C:\Program Files (x86)\Java\jre7\bin\javaw.exe args is: null native platform is: Windows, x86 [ x86, 32bit ] JavaFX runtime is: JavaFX 2.2.7 found at C:\Program Files (x86)\Java\jre7\ enabled is: true registered is: true system is: true Match: ignoring maxHeap: -1 Match: ignoring InitHeap: -1 Match: digesting vmargs: null Match: digested vmargs: [JVMParameters: isSecure: true, args: ] Match: JVM args after accumulation: [JVMParameters: isSecure: true, args: ] Match: digest LaunchDesc: http://localhost:7001/p6/action/jnlp/appletsjnlp.jnlp?mainClass=com.primavera.pvapplets.adminpreferences.AdminPreferencesApplet&classPath=adminpreferences.jar,prm-applets-common.jar,forms-1.0.7.jar,prm-guisupport.jar,prm-to.jar,jide.jar,tablesupport.jar,formsupport.jar,applets-bo.jar,commons-lang.jar,prm-common.jar,resource_strings.jar,prm-img.jar,commons-logging.jar&name=AdminPreferences&version=8.1.2.0.0602 Match: digest properties: [] Match: JVM args: [JVMParameters: isSecure: true, args: ] Match: endTraversal .. Match: JVM args final: Match: Running JREInfo Version match: 1.7.0.17 == 1.7.0.17 Match: Running JVM args match: have:<> satisfy want:<> Java Plug-in 10.17.2.02 Using JRE version 1.7.0_17-b02 Java HotSpot(TM) Client VM User home directory = C:\Users\gwrichard ---------------------------------------------------- c: clear console window f: finalize objects on finalization queue g: garbage collect h: display this help message l: dump classloader list m: print memory usage o: trigger logging q: hide console r: reload policy configuration s: dump system and deployment properties t: dump thread list v: dump thread stack x: clear classloader cache 0-5: set trace level to <n> ----------------------------------------------------

    Read the article

  • [MFC] Creating multiple dialogs in an MFC app with no main Window, they become children of each othe

    - by John
    (title updated) Following on from this question, now I have a clearer picture what's going on... I have a MFC application with no main window, which exposes an API to create dialogs. When I call some of these methods repeatedly, the dialogs created are parented to each other instead of all being parented to the desktop... I have no idea why. But anyway even after creation, I am unable to change the parent back to NULL or CWnd::GetDesktopWindow()... if I call SetParent followed by GetParent, nothing has changed. So apart from the really weird question of why Windows is magically parenting each dialog to the last one created, is there anything I'm missing to be able to set these windows as children of the desktop? UPDATED: I have found the reason for all this, but not the solution. From my dialog constructor, we end up in: BOOL CDialog::CreateIndirect(LPCDLGTEMPLATE lpDialogTemplate, CWnd* pParentWnd, void* lpDialogInit, HINSTANCE hInst) { ASSERT(lpDialogTemplate != NULL); if (pParentWnd == NULL) pParentWnd = AfxGetMainWnd(); m_lpDialogInit = lpDialogInit; return CreateDlgIndirect(lpDialogTemplate, pParentWnd, hInst); } Note: if (pParentWnd == NULL)pParentWnd = AfxGetMainWnd(); The call-stack from my dialog constructor looks like this: mfc80d.dll!CDialog::CreateIndirect(const DLGTEMPLATE * lpDialogTemplate=0x005931a8, CWnd * pParentWnd=0x00000000, void * lpDialogInit=0x00000000, HINSTANCE__ * hInst=0x00400000) mfc80d.dll!CDialog::CreateIndirect(void * hDialogTemplate=0x005931a8, CWnd * pParentWnd=0x00000000, HINSTANCE__ * hInst=0x00400000) mfc80d.dll!CDialog::Create(const char * lpszTemplateName=0x0000009d, CWnd * pParentWnd=0x00000000) mfc80d.dll!CDialog::Create(unsigned int nIDTemplate=157, CWnd * pParentWnd=0x00000000) MyApp.exe!CMyDlg::CMyDlg(CWnd * pParent=0x00000000) Running in the debugger, if I manually change pParentWnd back to 0 in CDialog::CreateIndirect, everything works fine... but how do I stop it happening in the first place?

    Read the article

  • What setting needs to be made to make .Net Automation responsive?

    - by Greg
    Have an app that is looking for application windows being created on the desktop using class Unresponsive { private StructureChangedEventHandler m_UIAeventHandler = new StructureChangedEventHandler(OnStructureChanged); public Unresponsive() { Automation.AddStructureChangedEventHandler(AutomationElement.RootElement, TreeScope.Children, m_UIAeventHandler); } private void OnStructureChanged(object sender, StructureChangedEventArgs e) { Debug.WriteLine("Change event"); } } You can see the same issue using UISpy.exe, selecting the desktop and configuring scope for children and just the structure changed event. The problem I'm trying to resolve is that the events are not raised in a timely manner, there seems to be some grouping/delay which makes the app appear to be non responsive. If you start a new app with 1 window and wait a second you get the event, seems alright. If you start the same app several times without delay (say clicking on quickstart), it's not until all of the instances of the app get 'initialised' by the AutomationProxies that you get the notice for the first app (and in short order the other apps/windows). I've sat watching task manager as each instance of the app starts to grow as it is initialised, waiting until the last app is done and then seeing the events all come in. Similarly any time any apps are starting windows within a timeframe there seems to be some blocking. I can't see how to configure this timeframe, or get each structure changed event to be sent on as soon as it happens. Also, this process of listening for structure changed events seems to be leaking, just by listening there is a leak in native memory. (visible in UISpy and my app)

    Read the article

  • How do I manage dependencies for automated builds on my build server?

    - by Tom Pickles
    I'm trying to implement continuous integration into our day to day workings. In our team, we're moving from just building our code in Visual Studio on our workstations and deploying, to using MSBuild.exe and automating on our build server (which is Jenkins) without the use of Visual Studio. We have external dependencies to references such as Automap in our projects. Because the automap (for example) dll isn't on the build server, the msbuild execution fails, for obvious reasons. There are other dll's which I need to be part of the build, I'm just using automap as an example. So what's the best way to get any dependencies onto the build server as part of the automated build? I've seen references to using a 'lib' folder, but I don't really understand where I should be putting it (in my project, filesystem, SVN ...?), and how the build server will get to it. I've also read that NuGet can do something with dependencies, but my build server isn't connected to the internet, and I don't understand how I can get my build to pull a NuGet package I may have created, and how it works together. Edit: I'm using subversion and we cannot use TeamCity as we would have to buy it and there's zero chance of funding.

    Read the article

  • Making pygtksourceview work in windows

    - by Dani
    So, I'm trying to get gtksourceview python bindings work under windows (I'm developing a cross platform gtk application that shows code, so gtksourceview seemed like a natural choice). I have pygtk installed and working (I followed the instructions in http://www.pygtk.org/downloads.html) I tried the instructions in http://projects.gnome.org/gtksourceview/ for gtksourceview. Here is what I did: Downloaded and extracted the latest gtksourceview window binaries from: http://ftp.gnome.org/pub/gnome/binaries/win32/gtksourceview/2.10/gtksourceview-2.10.0.zip The website said gtksourceview needs libxml, so I downloaded and extracted the latest libxml window binaries from: http://xmlsoft.org/sources/win32/libxml2-2.7.6.win32.zip Added the folders containing dll files to the PATH (in my computer they were c:\opt\gtksourceview\bin; C:\opt\libxml2-2.7.6.win32\bin) Installed pygtksourceview with the windows installer: http://ftp.gnome.org/pub/gnome/binaries/win32/pygtksourceview/2.10/pygtksourceview-2.10.0.win32-py2.6.exe Renamed the file libxml2.dll to libxml2-2.dll (after running depends on the gtksourceview dll) Now, the gtksouceview widget seems to work, until I'm trying to set the code's language. When I do that python crashes. Here is how I crash it in the console (the simplest way i could come up with): >>>import gtksourceview2 >>>lang = gtksourceview2.language_manager_get_default().get_language('cpp') >>>lang.get_style_ids() I'm hoping I'm not the first person to use gtksourceview in python on windows. Any ideas what I should try?

    Read the article

  • How to Detect in Windows Registry if user has .Net Framework installed?

    - by Sarah Weinberger
    How do I detect in the Windows Registry if a user has .Net Framework installed? I am not looking for a .Net based solution, as the query is from InnoSetup. I know from reading another post here on Stack Overflow that .Net Framework is an inplace upgrade to 4.0. I already know how to check if a user has version 4.0 installed on the system, namely by checking the following: function FindFramework(): Boolean; var bVer4x0: Boolean; bVer4x0Client: Boolean; bVer4x0Full: Boolean; bSuccess: Boolean; iInstalled: Cardinal; begin Result := False; bVer4x0Client := False; bVer4x0Full := False; bVer4x0 := RegKeyExists(HKLM, 'SOFTWARE\Microsoft\.NETFramework\policy\v4.0'); bSuccess := RegQueryDWordValue(HKLM, 'Software\Microsoft\NET Framework Setup\NDP\v4 \Client', 'Install', iInstalled); if (1 = iInstalled) AND (True = bSuccess) then bVer4x0Client := True; bSuccess := RegQueryDWordValue(HKLM, 'Software\Microsoft\NET Framework Setup\NDP\v4 \Full', 'Install', iInstalled); if (1 = iInstalled) AND (True = bSuccess) then bVer4x0Full := True; if (True = bVer4x0Full) then begin Result := True; end; end; I checked the registry and there is no v4.5 folder, which makes sense if .Net Framework 4.5 is an inplace upgrade. Still, the Control Panel Programs and Features includes the listing. I know that probably "issuing dotNetFx45_Full_setup.exe /q" will have no bad effect if installing on a system that already has version 4.5, but I still would like to not install the upgrade if the upgrade already exists, faster and less problems.

    Read the article

  • log4net 1.2 RollingFileAppender not working

    - by Rishi Poptani
    Hi Guys, I'm using log4net v1.2 with a Windows Service App. My RollingFileAppender seems not to work. I'm pasting the logging sections of my service.exe.config below. Can anyone advise where m going wrong? <section name="log4net" type="log4net.Config.Log4NetConfigurationSectionHandler,log4net"/> .....(lots of other config stuff) <appender name="RollingFileAppender" type="log4net.Appender.RollingFileAppender,log4net" > <param name="File" value="D:\\Trinity\\Booking\\OneDay_PostTrade\\logs\\Trinity.log" /> <param name="MaximumFileSize" value="20MB" /> <param name="MaxSizeRollBackups" value="10" /> <param name="StaticLogFileName" value="true" /> <param name="Threshold" value="ALL" /> <param name="RollingStyle" value="Composite" /> <param name="appendToFile" value="true" /> <layout type="log4net.Layout.PatternLayout,log4net"> <param name="ConversionPattern" value="%d [%t] %-5p %c - %m%n" /> </layout> </appender> ...(stuff in between) <root> <level value="ALL" /> <appender-ref ref="ConsoleAppender" /> <appender-ref ref="RollingFileAppender" /> </root> .....(stuff in between) <logger name="CSFB.PostTradeRulesEngine"> <level value="ALL"/> </logger>

    Read the article

  • IIS7 integrated mode MVC deploy 404 not found on some actions

    - by majkinetor
    Hello. Once deployed parts of my web-application stop working. Index-es on each controller do work, and one form posting via Ajax, other then that yields 404. I understand that nothing particular should be done in integrated mode. One interesting thing is that 1 AJAX action is working. I don't know how to proceed with troubleshooting. Some info: App is using default app pool set to integrated mode. WebApp is done in net framework 3.5. I use default routing model. Along web.config in root there is web.config in /View folder referencing HttpNotFoundHandler. OS is Windows Server 2008. Admins issued aspnet_regiis.exe -i IIS 7 Any help is appreciated. Thx. EDIT: Noticed one very strange thing. One ajax call works, other ajax call doesn't works as I login, but when I move to ther page and return to that one it starts working ?! Small video of the problem is available here

    Read the article

  • Trying to calculate large numbers in Python with gmpy. Python keeps crashing?

    - by Ryan Peschel
    I was recommended to use gmpy to assist with calculating large numbers efficiently. Before I was just using python and my script ran for a day or two and then ran out of memory (not sure how that happened because my program's memory usage should basically be constant throughout.. maybe a memory leak?) Anyways, I keep getting this weird error after running my program for a couple seconds: mp_allocate< 545275904->545275904 > Fatal Python error: mp_allocate failure This application has requested the Runtime to terminate it in an unusual way. Please contact the application's support team for more information. Also, python crashes and Windows 7 gives me the generic python.exe has stopped working dialog. This wasn't happening with using standard python integers. Now that I switch to gmpy I am getting this error just seconds in to running my script. I thought gmpy was specialized in dealing with large number arithmetic? For reference, here is a sample program that produces the error: import gmpy2 p = gmpy2.xmpz(3000000000) s = gmpy2.xmpz(2) M = s**p for x in range(p): s = (s * s) % M I have 10 gigs of RAM and without gmpy this script ran for days without running out of memory (still not sure how that happened considering s never really gets larger.. Anyone have any ideas? EDIT: Forgot to mention I am using Python 3.2

    Read the article

  • Project management: Implementing custom errors in VS compilation process

    - by David Lively
    Like many architects, I've developed coding standards through years of experience to which I expect my developers to adhere. This is especially a problem with the crowd that believes that three or four years of experience makes you a senior-level developer.Approaching this as a training and code review issue has generated limited success. So, I was thinking that it would be great to be able to add custom compile-time errors to the build process to more strictly enforce this and other guidelines. For instance, we use stored procedures for ALL database access, which provides procedure-level security, db encapsulation (table structure is hidden from the app), and other benefits. (Note: I am not interested in starting a debate about this.) Some developers prefer inline SQL or parametrized queries, and that's fine - on their own time and own projects. I'd like a way to add a compilation check that finds, say, anything that looks like string sql = "insert into some_table (col1,col2) values (@col1, @col2);" and generates an error or, in certain circumstances, a warning, with a message like Inline SQL and parametrized queries are not permitted. Or, if they use the var keyword var x = new MyClass(); Variable definitions must be explicitly typed. Do Visual Studio and MSBuild provide a way to add this functionality? I'm thinking that I could use a regular expression to find unacceptable code and generate the correct error, but I'm not sure what, from a performance standpoint, is the best way to to integrate this into the build process. We could add a pre- or post-build step to run a custom EXE, but how can I return line- and file-specifc errors? Also, I'd like this to run after compilation of each file, rather than post-link. Is a regex the best way to perform this type of pattern matching, or should I go crazy and run the code through a C# parser, which would allow node-level validation via the parse tree? I'd appreciate suggestions and tales of prior experience.

    Read the article

< Previous Page | 226 227 228 229 230 231 232 233 234 235 236 237  | Next Page >