  • How do I setup routing for two companies with different Internet connections on the same LAN?

    - by Clint Miller
    Here's the setup: Two companies (A & B) share office space and a LAN. A 2nd ISP is brought in and company A wants its own Internet connection (ISP A) and company B wants its own Internet connection (ISP B). VLANs are deployed internally to separate the two companies' networks (company A: VLAN 1, company B: VLAN 2, shared VOIP: VLAN 3). With separate VLANs it's simple enough to use separate DHCP servers (or separate scopes on the same server) to assign the default gateway to each company's gateway for their Internet connection. Static routes can be created on each gateway to point traffic destined for the other company's VLAN or the voice VLAN so that all nodes are reachable as expected. However, I think this is a form of asymmetrical routing, right? (The path from node A1 to node B1 is not the same as the path back from node B1 to node A1). Can I set up policy-based routing to correct this? In that case, can I assign the same default gateway to every device on all VLANs and create a routing policy on a L3 switch to look at the source address and forward traffic to the appropriate next hop? In that case, I want the routing logic to go like this: If the destination address is known, forward the traffic (traffic destined for a different VLAN). If the destination address is unknown, forward the traffic to ISP A's gateway if the source address is on VLAN A; or forward the traffic to ISP B's gateway if the source address is VLAN B. Am I thinking about this problem in the correct way? Is there another way to solve this problem that I am overlooking?

    Read the article

  • Allied Telesis router: IP filtering for the LOCAL interface

    - by syneticon-dj
    Given an Allied Telesis router with an AlliedWare OS (2.9.1) I would like to disable access to all management services of the router except for a number of subnets (or alternatively have what is a "management VLAN" with other manufacturers' switch and router models). What I have tried so far: creating a new VLAN and an appropriate IP interface, setting the LOCAL IP into this subnet, creating an IP filter for the IP interface and specifying my exclusion subnets: it simply does not work as intended as I can access the LOCAL IP set from any of the other VLAN interfaces - the traffic is apparently not going through my defined filter set at all creating a new IP filter set and binding it to the LOCAL IP interface: this seems not to affect any kind of traffic at all, the counters for the filter set remain at zero packets setting the Remote Security Officer Level IP address range: this only restricts the ability for a user with the Security Officer privilege level to log in from any but the specified address ranges / subnets. Unfortunately, it does not prevent service availability (and thus DoS capacity) or the ability to log in as a less privileged user (e.g. a "manager") calling technical support: unfortunately no solution so far What I have not tried: creating a filter set for each and every IP interface defined on the router and excluding access to the router's management IP: I would like to reduce the overhead induced by IP filters as the router already is CPU-constrained at times. Setting up filters for every IP interface would mean that each and every traffic packet would have to pass the filters, thus consuming CPU cycles. If by any means possible, I would like to find a different solution.

    Read the article

  • Out of memory errors but not actually out of memory...

    - by commradepolski
    So, myself and my fellow support techs have been fighting with this issue and we still dont know what the problem is. Lets start off with the system specs: Windows XP 32 bit Corporate (SP2 and SP3) Intel D975XBX2 Mobo 4gb of ram Intel Core 2 Quad Q6600 ATI Radeon HD 3600 - 512mb After a few hours of working on the machine, the end user will begin to see the following symptoms: Out of memory messages Title bars and menus dont draw in properly Problems accessing network resources Problems opening up documents such as MSWord and MSPowerpoint and text files Problems opening up explorer windows General instability We have looked at task manager while this issue was occurring, and all indicators, like PF usage, threads, handles, etc. are normal. We have been having trouble pinpointing the root cause of this issue. It is also not situated with one user, it affects 8-10. So far we have tried: Resetting CMOS (Waiting to see results) Replacing video card (didnt help) Windows updates (didnt help) Updating network drivers (didnt help) Switching user from 1gbps to 100mbps network connection (awaiting results) Swapping the affected user's hardware (waiting for results) Increasing desktop heap size (helped for a bit but then the issue became more frequent) Applying the /3 switch to XP (didnt help) Increasing and decreasing and setting PF to system managed state (didnt help) We did have a power outage at the office a couple weeks ago, and all these issues became more frequent. Prior to the power outage it may take a week or so for the users to experience the issues but since the power outage it takes 3-4 hours or less. We havent had reports of the above issues causing BSODs, although that would be easier to diagnose :). Any help is greatly appreciated.

    Read the article

  • Apache with multiple domains, single IP, VirtualHost is catching the wrong traffic

    - by apuschak
    I have a SOAP web service I am providing on a apache web server. There are 6 different clients (IPs) that request data and 3 of them are hitting the wrong domain. I am trying to find a way to log which domain name the requests are coming from. Details: ServerA is the primary ServerB is the backup domain1.com - the domain the web service is on domain2.com - a seperate domain that server seperate content on ServerB ServerA is standalone for now with its own IP and DNS from domain1.com. This works for everyone. ServerB is a backup for the web service, but it already hosts domain2.com. I added entries into the apache configuration file like: <VirtualHost *:443> ServerName domain2.com DocumentRoot /var/www/html/ CustomLog logs/access_log_domain2443 common ErrorLog logs/ssl_error_log_domain2443 LogLevel debug SSLEngine on ... etc SSL directives ... </VirtualHost> I have these for both 80 and 443 for domain1 and domain2 with domain1 being second. The problem is when we switch DNS for domain1 from ServerA to ServerB, 3 out of the 6 clients show up in the debug logs as hitting domain2.com instead of domain1.com and fail their web service request because domain2.com is first in the apache configuration file and catching all requests that don't match other virtualhosts, namely domain1.com. I don't know if they are hitting www.domain1.com, domain1.com (although I added entries for both) or using the external IP address or something else. Is there a way to see which URL they are hitting not just the page request or someother way to see why the first domain is catching traffic meant for the second listed domain? In the meantime, I've put domain1.com higher in the apache configuration than domain2.com. Now it catches the requests for all clients and works, however I don't know what it is catching and would like to make domain2.com the first entry again with a correct entry for domain1.com, for however they are hitting it. Thank you for your help! Andrew

    Read the article

  • file read performance degrades as number of files increases

    - by bfallik-bamboom
    We're observing poor file read IO results that we'd like to better understand. We can use fio to write 100 files with a sustained aggregate throughput of ~700MB/s. When we switch the test to read instead of write, the aggregate throughput is only ~55MB/s. The drop seems related to the number of files since the throughput for read and write are comparable for a single file then diverge proportionally as we increase the number of files. The test server has 24 CPU cores, 48GB of memory, and is running CentOS 6.0. The disk hardware is a RAID 6 array with 12 disks and a Dell H800 controller. This device is partitioned with ext4 using the default settings. Increasing the readahead (using blockdev) improves the read throughput significantly but it still doesn't match write speed. For instance, increasing the readahead from 128KB to 1M improved the read throughput to ~145MB/s. Is this a known performance issue in our OS/disk/filesystem configuration? If so, how can we tell? If not, what tools or tests can we use to further isolate the issue? Thanks.

    Read the article

  • Why is my rsync so slow?

    - by iblue
    My Laptop and my workstation are both connected to a Gigabit Switch. Both are running Linux. But when I copy files with rsync, it performs badly. I get about 22 MB/s. Shouldn't I theoretically get about 125 MB/s? What is the limiting factor here? EDIT: I conducted some experiments. Write performance on the laptop The laptop has a xfs filesystem with full disk encryption. It uses aes-cbc-essiv:sha256 cipher mode with 256 bits key length. Disk write performance is 58.8 MB/s. iblue@nerdpol:~$ LANG=C dd if=/dev/zero of=test.img bs=1M count=1024 1073741824 Bytes (1.1 GB) copied, 18.2735 s, 58.8 MB/s Read performance on the workstation The files I copied are on a software RAID-5 over 5 HDDs. On top of the raid is a lvm. The volume itself is encrypted with the same cipher. The workstation has a FX-8150 cpu that has a native AES-NI instruction set which speeds up encryption. Disk read performance is 256 MB/s (cache was cold). iblue@raven:/mnt/bytemachine/imgs$ dd if=backup-1333796266.tar.bz2 of=/dev/null bs=1M 10213172008 bytes (10 GB) copied, 39.8882 s, 256 MB/s Network performance I ran iperf between the two clients. Network performance is 939 Mbit/s iblue@raven $ iperf -c 94.135.XXX ------------------------------------------------------------ Client connecting to 94.135.XXX, TCP port 5001 TCP window size: 23.2 KByte (default) ------------------------------------------------------------ [ 3] local 94.135.XXX port 59385 connected with 94.135.YYY port 5001 [ ID] Interval Transfer Bandwidth [ 3] 0.0-10.0 sec 1.09 GBytes 939 Mbits/sec

    Read the article

  • Two network adapters in one WindowsXP PC, how to make them work?

    - by Deele
    I have a need to set up network so I can use two ethernet cards inside one Windows (Windows XP SP2) based PC, one for internet connection, second, for internal LAN. How should I configure each NIC, with what IP's, subnet masks and gateways, so I can use inernet on my PC and get in touch with devices on my LAN? I have found that there are some sort of re routing nessesary inside my PC, but how does it work? I have already set up some configuration already, but I can't use it together with PC #1 NIC #1 connected. I need to disconnect, to access NIC WEB interface. Current configuration: Switch #1 and PC #1 NAS #2 are gigabit one's, so I could access NAS with gigabit speed. PC #1 NIC #1 IP XX.XXX.162.106 SN 255.255.255.248 GW XX.XXX.162.105 PC #1 NIC #2 IP 10.0.0.1 SN 255.255.0.0 GW 0.0.0.0 NAS #1 NIC #1 IP 10.0.0.12 SN 255.255.0.0 GW 0.0.0.0 My question is - what exact configuration should I do for every NIC in this LAN, so it would work? Is it possible to achieve internet access for Laptop, that is inside that NIC #2 LAN (should I just set up basic ICS)?

    Read the article

  • Why is my browser using so much memory?

    - by Steve
    Hi. I've recently had problems with Firefox running very slowly when I have many tabs open; say 20 tabs. My whole system would slow down. I decided to give Google Chrome a try, and it started out fine. But lately I am finding that it too, slows down my whole system. Looking at Task Manager, chrome.exe is using about 250MB of memory in about 6 different entries in task manager. However, when I shut Chrome down, memory usage is reduced by about 600MB. How can this be? (shows drop in memory usage after ending Chrome.) When my system locks up with Chrome having many tabs open, it takes 10 seconds to load the Start Menu, 10 seconds to expand All Programs, and each folder and subfolder, and 30 seconds for the program to be highlighted under my mouse. It also takes 10 seconds to switch to Notepad. Why is Chrome appearing to use so much more memory than Task Manager indicates? Why is my pagefile being used when I have around 1.1GB of memory? Can I set Chrome to run in RAM and not in the pagefile? How can 20 tabs use 600MB? That's 30MB per tab. Thanks for your help.

    Read the article

  • Prevent rmdir -p from traversing above a certain directory

    - by thepurplepixel
    I hacked together this script to rsync some files over ssh. The --remove-source-files option of rsync seems to remove the files it transfers, which is what I want. However, I also want the directories those files are placed in to be gone as well. The current part of the find command, -exec rmdir -p {} ; tries to remove the parent directory (in this case, /srv/torrents), but fails because it doesn't have the right permissions. What I'd like to do is stop rmdir from traversing above the directory find is run in, or find another solution to get rid of all the empty folders. I've thought of using some kind of loop with find and running rmdir without the -p switch, but I thought it wouldn't work out. Essentially, is there an alternative way to remove all the empty directories under the parent directory? Thanks in advance! #!/bin/bash HOST='<hostname>' USER='<username>' DIR='<destination directory>' SOURCE='/srv/torrents/' rsync -e "ssh -l $USER" --remove-source-files -h -4 -r --stats -m --progress -i $SOURCE $HOST:$DIR find $SOURCE -mindepth 1 -type d -empty -prune -exec rmdir -p \{\} \;

    Read the article

  • How to stop Vista from auto changing video resolution?

    - by bialix
    I have new Acer Aspire Revo R3600 computer with Vista pre-installed. The computer has NVidia video adapter. While connecting 17" LCD monitor (LG L1742S) via VGA cable it works fine, and I can change the resolution of the display from max 1920*1024 down to some other value, and after reboot the settings are restored correctly. But when I'm connecting bigger full HD 1920*1080 display (LG E2250) via VGA cable then every boot I have the same problem: I see boot progress window, then I see MS logo, then I see welcome screen then I start to see desktop and suddenly monitor switch off and show me the message about unsupported frequency of input signal As I understand Vista tries to auto-change resolution and sets wrong parameters. I've tried to boot into safe mode and into low-resolution mode, every time I have the same problem: Vista boot-up and suddenly monitor stops working. I've tried to connect this monitor to notebook with Windows XP and has no problem to work with this display on its native resolution. How can I disable this display resolution auto-changer in Vista? Or maybe there is another workaround?

    Read the article

  • Shortcuts that make using Windows easier? [closed]

    - by ekaj
    Over the years I have found out a good bit of shortcuts, all of which make using Windows that much faster and easier. I was wondering if I had missed any important ones, or ones that just saved any time. I tried to keep these relative to Windows only, as programs such as Mozilla, Photoshop, etc. bring in hundreds of other shortcuts, which do not apply to all users. These are the current ones I know: For the mouse: Scroll wheel - opens a link in IE into a new tab - closes a specific tab in IE when closed on Right click-n-drag - nifty menu to make a copy of a file or create a shortcut For the keyboard: Cntrl + Alt + Del - need this be explained? WinKey + R - opens 'Run..' WinKey + D - shows the desktop WinKey + E - opens 'My Computer' WinKey + F - opens 'Find..' WinKey + Tab - cool way to switch inbetween windows WinKey + L - locks the computer Alt + Tab - switches windows with a simple interface Alt + F4 - closes windows Alt + F - opens 'File' (Handy for things like IE if you have the menubar disabled) Cntrl + F - find text on current document Cntrl + W - closes a window, or current active tab in IE (or IE itself if only one tab) Cntrl + C - copies selected text / image Cntrl + V - pastes selected text / image So does anyone know of any more shortcuts that just make life easier? I would be much appreciative of any, and I am sure that some other users would like to know some too =]

    Read the article

  • iptables (DNAT)

    - by user1126425
    I have a host that acts as a gateway for other hosts. The configuration is such that eth0(192.168.1.3) is connected to internet via a router and eth1(172.16.2.50) is connected to internal network via switch. Given that, this host is also running a service that is bound to eth1 and serves the internal network. I want to extend this service to the outside world as well and was trying to manipulate iptables so that any request that comes to this host via eth0 and is directed to 192.168.1.3:80 is send to 172.16.2.50 and internet users can also make use of the service. Here are my iptable rules for setting up the host as gateway (and these work fine): sudo iptables -t nat -A POSTROUTING -s 172.16.2.0/16 -o eth0 -j MASQUERADE sudo iptables -t nat -A POSTROUTING -s 192.168.1.0/24 -o eth1 -j MASQUERADE sudo iptables -A FORWARD -s 172.16.2.0/16 -o eth0 -j ACCEPT sudo iptables -A FORWARD -d 172.16.2.0/16 -m state --state ESTABLISHED,RELATED -i eth0 -j ACCEPT And these are the rules that I am trying to add to the iptables to achieve my ends: sudo iptables -A INPUT -d 192.168.1.3 -p tcp -dport 80 -i eth0 -j ACCEPT sudo iptables -t nat -A PREROUTING -d 192.168.1.3 -p tcp -dport 80 -j DNAT --to-destination 172.16.2.50:80 sudo iptables -t nat -A PREROUTING -s 172.16.2.50 -p tcp -sport 80 -j SNAT --to-source 192.168.1.3:80 sudo iptables -A FORWARD -d 192.168.1.3 -p tcp -dport 80 -m state --state ESTABLISHED,RELATED -j ACCEPT When I do so, I get error like : "multiple -d flags not allowed" ... Can someone tell me how to resolve this error... and do the entries that I want to add will serve my purpose ? Thanks!

    Read the article

  • Bind9 not doing anything with forwarded query responses?

    - by Rykaro
    I have a Bind DNS server that is the local production DNS server and a Windows 2008 R2 domain controller which provides DNS for a lab environment with the domain xyz.lab. I've configured the Bind DNS to forward DNS requests for the domain xyz.lab to the Windows DNS server with this config: zone "xyz.lab" { type forward; forward only; forwarders { x.x.x.x; }; }; zone "x.x.x.in-addr.arpa" { type forward; forward only; forwarders { x.x.x.x; }; }; And Bind options are (the all_internal acl includes the subnets of both the production and lab networks as well as the loopback of the bind server): allow-query { all_internal; }; allow-recursion { all_internal; }; allow-transfer { none; }; notify no; minimal-responses yes; version "unknown"; Unfortunately, when I do an nslookup or dig on the bind server for a host on the lab domain, the request times out. The logs on the Windows 2008 DNS server show it receiving the query and responding to it and a network packet trace shows the query responses arriving at the Bind DNS server. The servers reside on the same switch with a router providing connectivity between the layer 3 subnets (production and lab are on different subnets) and there is a round trip time of between 3ms and 5ms on pings between the two servers, so I don't think there is an issue with latency causing a timeout of the query. In summary a query-response arrives back at the Bind server and the nslookup/dig times-out. Why does the Bind DNS not seem to be doing anything with the query responses when it receives them?

    Read the article

  • Identifying test machines in analytics logs

    - by RTigger
    We're just beginning to add analytics to our SaaS application, to begin (among other things) billing clients based on usage. The problem we're running into is there's a few circumstances where our support team will simulate a log in into production to try to reproduce reported issues with a client's configuration. When they log in, an entry will be made into our analytics logs that their specific account has logged in, which we use to calculate billing. A few ideas we had to solve this: 1) We log IP addresses as well as machine keys for each PC that logs in - we could filter out known IP addresses and/or machine keys belonging to support. The drawback is we have to maintain a list of keys / addresses manually. 2) If support (or anyone else internal) runs our application in debug mode (as opposed to release), it will not report analytics. This is fine, as long as support / anyone else remembers to switch to debug mode. 3) Include some sort of reg key / similar setting required to be set when configuring a production system in order to send analytics. Again, fine, as long as our infrastructure team remembers to set the reg key or setting. All of these approaches require some sort of human involvement, which we all know can be iffy at best. Has anyone run into a similar situation? Is there an automated approach to this problem? (PS Of course, we shouldn't be testing in production, but there are a few one-off instances with customer set up that we can't reproduce without logging in as them in production. This is the only time we do so, and this is the case I'm talking about in this question.)

    Read the article

  • wireless clients not getting correct dhcp addresses

    - by szeli
    I apologise first if this is a stupid problem. I'm new to Cisco networking. I need some help with an existing configuration done by my vendor. Environment: 1. Core switch - Catalyst 6509e vlans configured: a. vlan 50 (wired clients) 10.0.50.x/24 interface IP 10.0.50.20 b. vlan 70 (wireless clients) 10.0.70.x/24 interface IP 10.0.70.20 c. vlan 192 (guest clients) 192.168.1.x/24 interface IP 192.168.1.20 d. trunk port for WLC native vlan 70 allowed vlan 50, 70, 192 2. Cisco 4402 WLC interfaces a. management untagged IP 10.0.70.10 b. ap-manager untagged IP 10.0.70.11 c. service-port n/a IP 192.168.10.1 d. virtual n/a IP 1.1.1.1 e. guestwlan vlan192 IP 192.168.1.100 3. Cisco AIR-LAP1142N-S-K9 LAP01 (WLAN local, interface: management) IP 10.0.70.21/24 GW 10.0.70.20 DHCP server 10.0.50.10 (scope 10.0.70.101 to 200) LAP02 (WLAN guest, interface: guestwlan) IP 192.168.1.21/24 GW 192.168.1.20 DHCP server 192.168.1.10 (scope 192.168.1.101 to 200) here's the problem, wireless clients connected to WLAN guest keep getting DHCP leases from WLAN local 10.0.50.10 (scope 10.0.70.101 to 200) can anyone please help? thanks!

    Read the article

  • 4GB Memory Upgrade for Acer Aspire 5102WLMi

    - by Richard Slater
    I have bought a 4GB memory upgrade (2x 2GB PC2-5300 SODIMM) for my Acer Aspire 5102WLMi (Aspire 5100 Series) laptop, I installed the two memory modules correctly however with 4GB installed the laptop refuses to POST. I have tried the following: Tried both 2GB SODIMMs without the other (Worked Fine) Tried the original 512MB SODIMMs (Worked Fine) Tried with original 512MB SODIMM and new 2GB SODIMM (Worked Fine) Tried swapping over the 2GB SODIMs (Didn't Boot) Left the computer for 10 minutes with both 2GB SODIMMs installed (Didn't Boot) Checked latest BIOS installed (No Change) The Crucial website said that the laptop supported 4GB of RAM as do several other sites through found through Google, up until now I was fairly confident this would work. Couple of questions that would be good to have answered: Question: Has anyone got an Acer Aspire 5100 Series running with 4GB RAM? Answer: Yes, I have now got one working with 3.75GB Usable, the rest is occupied utilized by the Graphics Card. Question: Any tips on getting this to work; is there a CMOS reset switch? Answer: Yes there is, if both SODIMMs are removed two very small interlocking PCB tracks are revealed. If these are shorted together with a screwdriver the BIOS will be reset. Thanks.

    Read the article

  • LMDE detects a wireless card, but can't use it

    - by Davidos
    LMDE can see my wireless card, and correctly identifies it, but it refuses to let me turn it on through the shiny graphical interface. Is there a way to use the non-shiny terminal to turn on my wireless? One small tidbit I noticed was the stated version; it says the version is 00. I believe that's hexadecimal for 0, which may indicate something screwy with the software. It would be nice if someone could tell me how to figure out how to solve this kind of problem in the future. *-network DISABLED description: Wireless interface product: Centrino Wireless-N 1000 vendor: Intel Corporation physical id: 0 bus info: pci@0000:09:00.0 logical name: wlan0 version: 00 serial: 91:e3:7b:0d:a3:a9 width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list ethernet physical wireless configuration: broadcast=yes driver=iwlagn driverversion=3.0.0-1-amd64 firmware=39.31.5.1 build 35138 latency=0 link=no multicast=yes wireless=IEEE 802.11bgn resources: irq:43 memory:e1d00000-e1d01fff I've tested multiple other network managers, and none of them work. W ireless switch is on, I'm sure it's a driver problem.

    Read the article

  • How does everyone set up AWS for PHP with a git workflow while worrying about distributing EC2?

    - by Parris
    Hello, I have been looking for something like heroku but for php, and after much frustration (and almost finding what I need, but not quite) we decided to just go with AWS without any other abstraction. We are using PHP 5.3 (and CakePHP 1.3), and are currently using git. Ubuntu seems like the easiest way to get both of those on there and we will most likely use that. We aren't really going worry about outgoing email. We are using smtp through gmail, but will most likely switch to some other service eventually. I had 3 questions: 1) I have been looking at Zend Server, and I am not quite sure how that is more beneficial than xampp. Perhaps it is not? 2) I suppose to make the application scale we would need multiple instances of some ec2 ami. Then just duplicate it and such. The question then becomes how do we make sure all EC2 instances are up to date? 3) I understand the concept of load balancing to some degree. I understand that in 1 region you select a bunch of servers and have it load balance across them. The question then becomes well how about world wide? How do I make it so that traffic is directed to the correct ec2 server? I have heard of route 53, and tried signing up for that, but nothing appears in my control panel. Also perhaps it is just a DNS thing with my domain registrar? AHHH... some tutorial would be helpful!

    Read the article

  • Windows 8 Communication Sound Setting not working

    - by blackmastiff
    I've been having a problem on my new laptop recently which is familiar but baffling the usual fixes. I'm running Windows 8 with an onboard Realtek soundcard. It's similar to the one on my older computer running Windows 7. The problem is, when I'm in Skype or Mumble, Windows changes the sound output to lower everything else automatically. I've disabled the communications sound change option on the communications tab within sound devices and checked all the applications settings to insure that they are not responsible. They aren't, and I noticed something else. When I'm in the sound properties dialog, and I switch to the microphone tab, the same audio output reduction occurs. This seems to say to me that the microphone must be responsible in some way, but seeing as I uninstalled all the drivers and installed windows drivers instead, I'm confused as to why this would be occurring. Any thoughts? EDIT: I just tried disabling the built in microphone and the sound no longer get changed. More confused now? As soon as I turn it back on, the sound gets dropped again. Incidentally, the fix for this on windows 7 was this question: Windows 7 lowers applications' volume automatically I've got my computer set that way and it doesn't work.

    Read the article

  • Is it possible to update Lenovo T500 hybrid graphics driver?

    - by Shiki
    Hope someone had the same problem before. My laptop comes with two video "cards". Intel MHD4500 and ATI Radeon HD3650 (mobility). I can switch between them with the "Lenovo Battery Manager" from the taskbar. All good, but Lenovo provides the driver for this. The problem with that driver is they are a bit old. (Both Intel and ATI). For example I doubt I have any gpu accel in flash, and I experience some problem with dual display setup, which the new ATI driver would solve. Basically I want to create a new driver (I read a topic where a guy said its possible... baaack then when I was searching for something else). One needs a special ATI driver creation utility or what... sorry I can't recall the name of it. Thanks in advance. (Ah yes I forgot: The OS is a Windows 7 x64 Ultimate.)

    Read the article

  • Graphics card ATI Asus 9250 128 MB AGP problem.Monitor switching off.

    - by Dominick1978
    I have an old system with these specs: Motherboard: Via P4x266a (with AGP 4x) CPU: P4 1,7 Ghz Memory: 1152 MB DDR SDRAM Graphics card: Voodoo 3 2000 16 MB PSU: 300 Watt It also has 1 dvd-rom, 1 dvd-rw, 2 hard drives (all 4 connected via molex) , 1 sounblaster sound card and 1 ethernet card (both connected via pci). OS: XP Pro Recently I bought Asus 9250 128 MB AGP to replace voodoo.Wnen I switch on the pc the initial screens (until after the xp logo) sometimes are distorted with blurred colours.When XP are loaded there is some flickering but the rest are ok.XP can't recognize the card seeing it as just a VGA adapter.I have downloaded the latest xp drivers from ATI website and installed them.Then after the restart everything is ok (no distorted image or blurring) until after the xp logo.After this the monitor turns off while the pc is still running.I have tried many drivers but the problem persists (of course I removed the voodoo drivers before from the display adapter properties).Only once I have managed to enter XP (after changing BIOS features for graphics card from 256 MB to 128 MB) but the drivers on the control panel had an exclamation mark (ati 9250!) and below them ati 9250 secondary without ! under the display adapter tab and the ATI catalyst program said that it couldn;t find the card.That was the opnly time I went beyond the xp logo.Now the monitor auto switcheS off. So, what do you think? 1)Is this a broken card? 2)Is it the drivers of the card? 3)Is it PSU fault? 4)Anything else? Thanks for your help and excuse my english!

    Read the article

  • HP LaserJet 1515: Disable "refill" warning

    - by Pekka
    I have a HP LaserJet 1515 connected to a Windows 7 PC. The Magenta cartridge is empty; the printer shows a warning to that effect, and won't let me print even black-and-white documents any more. I can't turn the warning off manually using the printer's small console: When I try to enter any menu, the display says "Menu access disabled". I have no idea why. There is a setting to override the warning, but it can't be changed using the Network interface in the browser (Although it is there on the status page) According to the manual,the HP printing tool is supposed to offer a switch for this, but it won't install on my Windows 7. It just rumbles about for half an hour, to magnificently exit with an "unknown error" requiring a reboot. On second look, the problem seems to be that Windows 7 just isn't supported. There is no download link for the tool when you specify Windows 7 as your OS. I just want to print a black-and-white-document on a printer whose black cartridge is still 65% full. Is this indeed impossible? On second thought, I'm cross-posting this on the HP support forum. I'll update here if anything comes up.

    Read the article

  • trying to setup multiple primary partitions on ubuntu linux [migrated]

    - by JohnMerlino
    I currently have ubuntu desktop installed on a harddrive. I want to partition the harddrive so that I can reserve 30 gigs for ubuntu server and 30 gigs for ubuntu desktop. The drive has 300 gigs available. Right now I am booting from dvd drive and installing ubuntu server. I selected "Guided partitioning" and created a 30 gig primary partition of Ext4 journaling filesystem, set "yes, format it" for format partition and set bootable flag to on. I intend to use this 30 gig partition to hold ubuntu server and allow me to boot from it. Now I have two other partitions. They are both set to "logical", one is currently using 285.8 gigs and is using ext4 (when I try to set bootable flag to true, it gives a warning "You are trying to set the bootable flag on a logical partition. The bootable flag is only useful on the primary partitions"). More alarming it says "No existing file system was detected in this partition". Actually, Im thinking that this is the parittion that is supposed to be holding my current Ubuntu Desktop. And of course I want this to be bootable and be a primary partition, so I could dual boot from this and the server partition. Now the third partition is also set to logical and it is being used as swap area. My question is regarding that second partition. Its supposed to be a primary partition thats holding my existing ubuntu desktop edition. How do I switch it to primary and to make sure that its pointing to my existing desktop installation?

    Read the article

  • Best way to patch (8) RJ45 ports from one room to another.

    - by zimmer62
    I have a 48 port patch panel in my basement, which I've wired almost all of them to various rooms around the house. Many are not actually being used at the moment, but pretty much all of them are wired to somewhere. As of recent, I've put in an HTPC in my media closet (different room), and I'm finding I need a lot more RJ45 plugs to this area. I have 4 drops here, and adding a switch will not solve my problems. I'm using the cabling for other things such as IR and Serial devices, not just Ethernet. What I'm hoping to do is add an 8 port panel in that media closet, and tie those into an 8 port panel on my rack next to the 48 port... What I don't want to do is pull 8 separate cables one by one from one area to the other unless someone has a technique that will allow me to do that quickly, and painlessly. Do they make cables with more conductors specifically for this purpose? Or patch panels that are designed for a special cable essentially just extending ports from one room to another?

    Read the article

  • What could cause a dual-monitor PC to suddenly stop using one of the screens?

    - by raldi
    I've got a dual-monitor setup using a GeForce 7900GT that was working fine for over a year... then suddenly, only one of the screens works. It's not OS-related, because even on startup, only one screen displays the BIOS checks. In the past, both screens would show it together. I didn't change anything to trigger this The monitor that gets a signal is random -- sometimes the one on the left goes black, sometimes the one on the right. The monitors and their cables are good -- I can switch both or either, and I get a signal just fine. They're plugged in, too. It's not the video card, either -- I have an identical 7900GT in another machine, and swapping the two didn't fix anything. It's not dust on the motherboard -- I pulled everything out, cleaned it off, checked for obvious damage, put it all back together, and no change. My next two steps are going to be to reset the CMOS info and to try swapping out the motherboard. Before I do that, does anyone have any other ideas?

    Read the article