Search Results

Search found 20796 results on 832 pages for 'active window'.

Page 282/832 | < Previous Page | 278 279 280 281 282 283 284 285 286 287 288 289  | Next Page >

  • glGetActiveAttrib on Android NDK

    - by user408952
    In my code-base I need to link the vertex declarations from a mesh to the attributes of a shader. To do this I retrieve all the attribute names after linking the shader. I use the following code (with some added debug info since it's not really working): int shaders[] = { m_ps, m_vs }; if(linkProgram(shaders, 2)) { ASSERT(glIsProgram(m_program) == GL_TRUE, "program is invalid"); int attrCount = 0; GL_CHECKED(glGetProgramiv(m_program, GL_ACTIVE_ATTRIBUTES, &attrCount)); int maxAttrLength = 0; GL_CHECKED(glGetProgramiv(m_program, GL_ACTIVE_ATTRIBUTE_MAX_LENGTH, &maxAttrLength)); LOG_INFO("shader", "got %d attributes for '%s' (%d) (maxlen: %d)", attrCount, name, m_program, maxAttrLength); m_attrs.reserve(attrCount); GLsizei attrLength = -1; GLint attrSize = -1; GLenum attrType = 0; char tmp[256]; for(int i = 0; i < attrCount; i++) { tmp[0] = 0; GL_CHECKED(glGetActiveAttrib(m_program, GLuint(i), sizeof(tmp), &attrLength, &attrSize, &attrType, tmp)); LOG_INFO("shader", "%d: %d %d '%s'", i, attrLength, attrSize, tmp); m_attrs.append(String(tmp, attrLength)); } } GL_CHECKED is a macro that calls the function and calls glGetError() to see if something went wrong. This code works perfectly on Windows 7 using ANGLE and gives this this output: info:shader: got 2 attributes for 'static/simplecolor.glsl' (3) (maxlen: 11) info:shader: 0: 7 1 'a_Color' info:shader: 1: 10 1 'a_Position' But on my Nexus 7 (1st gen) I get the following (the errors are the output from the GL_CHECKED macro): I/testgame:shader(30865): got 2 attributes for 'static/simplecolor.glsl' (3) (maxlen: 11) E/testgame:gl(30865): 'glGetActiveAttrib(m_program, GLuint(i), sizeof(tmp), &attrLength, &attrSize, &attrType, tmp)' failed: INVALID_VALUE [jni/src/../../../../src/Game/Asset/ShaderAsset.cpp:50] I/testgame:shader(30865): 0: -1 -1 '' E/testgame:gl(30865): 'glGetActiveAttrib(m_program, GLuint(i), sizeof(tmp), &attrLength, &attrSize, &attrType, tmp)' failed: INVALID_VALUE [jni/src/../../../../src/Game/Asset/ShaderAsset.cpp:50] I/testgame:shader(30865): 1: -1 -1 '' I.e. the call to glGetActiveAttrib gives me an INVALID_VALUE. The opengl docs says this about the possible errors: GL_INVALID_VALUE is generated if program is not a value generated by OpenGL. This is not the case, I added an ASSERT to make sure glIsProgram(m_program) == GL_TRUE, and it doesn't trigger. GL_INVALID_OPERATION is generated if program is not a program object. Different error. GL_INVALID_VALUE is generated if index is greater than or equal to the number of active attribute variables in program. i is 0 and 1, and the number of active attribute variables are 2, so this isn't the case. GL_INVALID_VALUE is generated if bufSize is less than 0. Well, it's not zero, it's 256. Does anyone have an idea what's causing this? Am I just lucky that it works in ANGLE, or is the nvidia tegra driver wrong?

    Read the article

  • ApiChange Corporate Edition

    - by Alois Kraus
    In my inital announcement I could only cover a small subset what ApiChange can do for you. Lets look at how ApiChange can help you to fix bugs due to wrong usage of an Api within a fraction of time than it would take normally. It happens that software is tested and some bugs show up. One bug could be …. : We get way too man log messages during our test run. Now you have the task to find the most frequent messages and eliminate the Log calls from the source code. But what about the myriads other log calls? How can we check that the distribution of log calls is nearly equal across all developers? And if not how can we contact the developer to check his code? ApiChange can help you too connect these loose ends. It combines several information silos into one cohesive view. The picture below shows how it is able to fill the gaps. The public version does currently “only” parse the binaries and pdbs to give you for a –whousesmethod query the following colums: If it happens that you have Rational ClearCase (a source control system) in your development shop and an Active Directory in place then ApiChange will try to determine from the source file which was determined from the pdb the last check in user which should be present in your Active Directory. From there it is only a small hop to an LDAP query to your AD domain or the GC (Global Catalog) to get from the user name his Full name Email Phone number Department …. ApiChange will append this additional data all of your query results which contain source files if you add the –fileinfo option. As I said this is currently not enabled by default since the AD domain needs to be configured which are currently only some hard coded values in the SiteConstants.cs source file of ApiChange.Api.dll. Once you got this data you can generate metrics based on source file, developer, assembly, … and add additional data by drag and drop directly into the pivot tables inside Excel. This allows you to e.g. to generate a report which lists the source files with most log calls in descending order along with the developer name and email in the pivot table. Armed with this knowledge you can take meaningful measures e.g. to ask the developer if the huge number of log calls in this source file can be optimized. I am aware that this is a very specific scenario but it is a huge time saver when you are able to fill the missing gaps of information. ApiChange does this in an extensible way. namespace ApiChange.ExternalData {     public interface IFileInformationProvider     {         UserInfo GetInformationFromFile(string fileName);     } } It defines an interface where you can implement your custom information provider to close the gap between source control system and the real person I have to send an email to ask if his code needs a closer inspection.

    Read the article

  • Mix metrics for June 14, 2010

    - by tim.bonnemann
    We've been busy working on a few improvements to Mix which we plan to roll out over the coming weeks. In the meantime, here are our latest community metrics once again: Registered Mix users (weekly growth) 64,769 (+0.9%) Active users (percent of total) Last 30 days: 4,682 (7.2%) Last 60 days: 8,251 (12.7%) Last 90 days: 11,936 (18.4%) Traffic (30-day) Visits: 13,674 Page views: 77,808 Twitter Followers: 3,451 List mentions: 205 User-generated content (30-day) New ideas: 29 New questions: 38 New comments: 167 Groups There are currently 1,440 Mix groups (requires login).

    Read the article

  • how this code works and how to modify this code to get my desrire work? [closed]

    - by imon_bayazid
    I dont understand how these code works here : m_MouseHookManager.MouseDoubleClick+=HookManager_MouseDoubleClick; m_MouseHookManager.MouseDoubleClick -= HookManager_MouseDoubleClick; m_KeyboardHookManager.KeyPress +=HookManager_KeyPress; m_KeyboardHookManager.KeyPress -=HookManager_KeyPress; My full Code is here : using System; using System.Windows.Forms; using MouseKeyboardActivityMonitor.WinApi; namespace MouseKeyboardActivityMonitor.Demo { public partial class TestFormHookListeners : Form { private readonly KeyboardHookListener m_KeyboardHookManager; private readonly MouseHookListener m_MouseHookManager; public TestFormHookListeners() { InitializeComponent(); m_KeyboardHookManager = new KeyboardHookListener(new GlobalHooker()); // Hooks are not active after instantiation. You need to use either Enabled property or call Start()()()() method m_KeyboardHookManager.Enabled = true;//True - The Hook is presently installed, activated, and will fire events. m_MouseHookManager = new MouseHookListener(new GlobalHooker()); m_MouseHookManager.Enabled = true; } #region Check boxes to set or remove particular event handlers. private void checkBoxMouseDoubleClick_CheckedChanged(object sender, EventArgs e) { if (checkBoxMouseDoubleClick.Checked) { m_MouseHookManager.MouseDoubleClick += HookManager_MouseDoubleClick; } else { m_MouseHookManager.MouseDoubleClick -= HookManager_MouseDoubleClick; } } private void checkBoxKeyPress_CheckedChanged(object sender, EventArgs e) { if (checkBoxKeyPress.Checked) { m_KeyboardHookManager.KeyPress +=HookManager_KeyPress; } else { m_KeyboardHookManager.KeyPress -=HookManager_KeyPress; } } #endregion #region Event handlers of particular events. They will be activated when an appropriate checkbox is checked. private void HookManager_KeyPress(object sender, KeyPressEventArgs e) { Log(string.Format("KeyPress \t\t {0}\n", e.KeyChar)); } private void HookManager_MouseDoubleClick(object sender, MouseEventArgs e) { Log(string.Format("MouseDoubleClick \t\t {0}\n", e.Button)); } private void Log(string text) { textBoxLog.AppendText(text); textBoxLog.ScrollToCaret(); } #endregion private void checkBoxEnabled_CheckedChanged(object sender, EventArgs e) { m_MouseHookManager.Enabled = checkBoxEnabled.Checked; m_KeyboardHookManager.Enabled = checkBoxEnabled.Checked; } private void radioHooksType_CheckedChanged(object sender, EventArgs e) { Hooker hook; if (radioApplication.Checked) { hook = new AppHooker();//Provides methods for subscription and unsubscription to application mouse and keyboard hooks. } else { hook = new GlobalHooker();//Provides methods for subscription and unsubscription to global mouse and keyboard hooks. } m_KeyboardHookManager.Replace(hook); m_MouseHookManager.Replace(hook);//hook->An AppHooker or GlobalHooker object. //Enables you to switch from application hooks to global hooks //and vice versa on the fly without unsubscribing from events. //Component remains enabled or disabled state after this call as it was before. //Declaration Syntax } private void HookManager_Supress(object sender, MouseEventExtArgs e) { if (e.Button != MouseButtons.Right) { return; } Log("Suppressed.\n"); e.Handled = true; } } } Can anybody help to understand that??? I want by this that whenever a F5 key-pressed my application will be active and then it checks if double-click happen it gives a message .... **How can i modify that.....??????**

    Read the article

  • Migrating from OCS 2007 R2 to Lync: Part 2

    In the story so far, Johan has described how to check that the migration from your OCS to Lync is supported and how to determine the requirements for the new installation This was followed by a walk-through of the preparation the Active Directory and installation of the first Lync Front End Server with a Mediation Server co-located. Now Johan tackles the merging the OCS configuration, and connection to the outsode world, followed by testing, performing and then validating the migration.

    Read the article

  • need advice for small css issue [migrated]

    - by JaPerk14
    I have a small design problem in my css, and I'd like to know if someone could check it out for me. The design problem is in the rollover effect of my horizontal navigation. There seems to be some sort of added margin or padding, but I'm having trouble finding the problem in the css. I will paste the code I'm using below, so you can see for yourself. You won't be able to see the problem until you rollover the navigation list items. HTML: <div class="Horiznav"> <ul> <li id="active"><a href="#">Link #1</a></li> <li><a href="#">Link #2</a></li> <li><a href="#">Link #3</a></li> <li><a href="#">Link #4</a></li> <li><a href="#">Link #5</a></li> </ul> </div> CSS: .Horiznav { background: #1F00CA; border-top: solid 1px #fff; border-bottom: solid 1px #fff; } .Horiznav ul { font-family: Arial, Helvetica, sans-serif; font-weight: bold; color: #fff; text-Align: center; margin: 0; padding-top: 5px; padding-bottom: 5px; } .Horiznav ul li { display: inline; } .Horiznav ul li a { padding-top: 5px; padding-bottom: 5px; color: #fff; text-decoration: none; border-right: 1px solid #fff; } .Horiznav ul li a:hover { background: #16008D; color: #fff; } #active a { border-left: 1px solid #fff; }

    Read the article

  • Using JQuery to set create a flexible 3 column layout with Divs

    - by Chris Hammond
    This evening I was working on creating a Full Width skin for http://www.sccaforums.com/ , the current skin is at a fixed width, which doesn’t work very well for an active Forum when you have a browser with a high resolution. (The site runs on DotNetNuke , so this post will feature examples for DotNetNuke, but the code is applicable to any HTML pages) Basically I wanted a three column layout, and depending on if there was content in the Left and Right columns, I wanted them to not display at all,...(read more)

    Read the article

  • How representative is Ohloh?

    - by gerrit
    My colleague recently pointed me to Ohloh, a website providing statistics on FOSS based on versioning repositories. It's quite a fun procrastination tool, e.g. to compare programming languages by active projects: Which makes me wonder: how representative is such a comparison? Can we draw conclusions from this such as "Javascript is the most used programming language in FOSS, followed closely by Python, Java and C++"? Or are there some big caveats to take into account?

    Read the article

  • breadcrumb dilemma -SEO impact

    - by HaCos
    i am updating the breadcrumb module of an commerce website, implementing microdata (schema.org). My dilemma is about showing last page: a.product name on breadcrumb or not? b.Should that be active link to current page or not? eg: http://www.google.com/webmasters/tools/richsnippets?url=http%3A%2F%2Fwww.urbanspoon.com%2Fr%2F23%2F1600592%2Frestaurant%2FPoint-Breeze%2FAlma-Pan-Latin-Kitchen-Pittsburgh urbanspoon example doesnt link last page, but is this right?

    Read the article

  • Environmental Variable for current domain

    - by Krzysztof Goszka
    I'm using Ubuntu 12.04 LTS Desktop edition I want to use environmental variable for currently joined domain just like i use $USER to bring current user. From what i read there are few variables for that but none seem to work for me. I also cannot see those variables as active when i type env command. I would appreciate a solution on how to enable that variable or how to make my own variable by pulling current domain name from the system somehow.

    Read the article

  • How to associate hardware volume control to USB speakers?

    - by Wolfger
    My Xubuntu system recognizes my speakers, and I can change the mixer settings to make them the active sound device, but no matter what I do, the hardware dial will only affect the onboard sound device. generic-usb 0003:046D:0A19.0003: input,hidraw1: USB HID v1.00 Device [ Logitech Logitech Z205 ] on usb-0000:00:1d.1-1/input2 updated to reflect the fact that this was Xubuntu desktop (from Kubuntu install originally) where I had this problem. I was able to easily do this from Ubuntu Natty installation.

    Read the article

  • Remote desktop from ubuntu to windows

    - by Deepak Rajput
    I want to take remote desktop from ubuntu to windows xp and 7,I am looking for a solution i can install software over the air. Vnc,Avoid installation of Vnc server in windows (policy problem) Looking software like Dameware in software is installed over the air and removed backed after the job is done. Should allow to control the current active desktop and interact with the user session. Please help me.

    Read the article

  • Message during Edit and Continue doesn't give an option to edit.

    - by Michael Freidgeim
    During my Edit and Continue session I received a message --------------------------- Microsoft Visual Studio --------------------------- Modifying a catch handler around an active statement will prevent the debug session from continuing while Edit and Continue is enabled. --------------------------- OK    --------------------------- I would expect that Visual Studio give me option to edit, but stop Edit and Continue or Cancel, but it only disallow edit .

    Read the article

  • How do I determine whether bumblebee is working as expected?

    - by Christian Fazzini
    I followed the instructions at https://wiki.ubuntu.com/Bumblebee sudo add-apt-repository ppa:bumblebee/stable sudo add-apt-repository ppa:ubuntu-x-swat/x-updates sudo apt-get update Instead of installing the proprietary nvidia drivers, via: sudo apt-get install bumblebee bumblebee-nvidia linux-headers-generic I did: sudo apt-get install --no-install-recommends bumblebee linux-headers-generic How do I determine that power savings mode is active and that my dedicated GPU isn't running? One thing that bugs me is that if I go to System Settings - Details - Graphics. Driver is shown as Unknown.

    Read the article

  • Data Source Connection Pool Sizing

    - by Steve Felts
    Normal 0 false false false EN-US X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman","serif";} One of the most time-consuming procedures of a database application is establishing a connection. The connection pooling of the data source can be used to minimize this overhead.  That argues for using the data source instead of accessing the database driver directly. Configuring the size of the pool in the data source is somewhere between an art and science – this article will try to move it closer to science.  From the beginning, WLS data source has had an initial capacity and a maximum capacity configuration values.  When the system starts up and when it shrinks, initial capacity is used.  The pool can grow to maximum capacity.  Customers found that they might want to set the initial capacity to 0 (more on that later) but didn’t want the pool to shrink to 0.  In WLS 10.3.6, we added minimum capacity to specify the lower limit to which a pool will shrink.  If minimum capacity is not set, it defaults to the initial capacity for upward compatibility.   We also did some work on the shrinking in release 10.3.4 to reduce thrashing; the algorithm that used to shrink to the maximum of the currently used connections or the initial capacity (basically the unused connections were all released) was changed to shrink by half of the unused connections. The simple approach to sizing the pool is to set the initial/minimum capacity to the maximum capacity.  Doing this creates all connections at startup, avoiding creating connections on demand and the pool is stable.  However, there are a number of reasons not to take this simple approach. When WLS is booted, the deployment of the data source includes synchronously creating the connections.  The more connections that are configured in initial capacity, the longer the boot time for WLS (there have been several projects for parallel boot in WLS but none that are available).  Related to creating a lot of connections at boot time is the problem of logon storms (the database gets too much work at one time).   WLS has a solution for that by setting the login delay seconds on the pool but that also increases the boot time. There are a number of cases where it is desirable to set the initial capacity to 0.  By doing that, the overhead of creating connections is deferred out of the boot and the database doesn’t need to be available.  An application may not want WLS to automatically connect to the database until it is actually needed, such as for some code/warm failover configurations. There are a number of cases where minimum capacity should be less than maximum capacity.  Connections are generally expensive to keep around.  They cause state to be kept on both the client and the server, and the state on the backend may be heavy (for example, a process).  Depending on the vendor, connection usage may cost money.  If work load is not constant, then database connections can be freed up by shrinking the pool when connections are not in use.  When using Active GridLink, connections can be created as needed according to runtime load balancing (RLB) percentages instead of by connection load balancing (CLB) during data source deployment. Shrinking is an effective technique for clearing the pool when connections are not in use.  In addition to the obvious reason that there times where the workload is lighter,  there are some configurations where the database and/or firewall conspire to make long-unused or too-old connections no longer viable.  There are also some data source features where the connection has state and cannot be used again unless the state matches the request.  Examples of this are identity based pooling where the connection has a particular owner and XA affinity where the connection is associated with a particular RAC node.  At this point, WLS does not re-purpose (discard/replace) connections and shrinking is a way to get rid of the unused existing connection and get a new one with the correct state when needed. So far, the discussion has focused on the relationship of initial, minimum, and maximum capacity.  Computing the maximum size requires some knowledge about the application and the current number of simultaneously active users, web sessions, batch programs, or whatever access patterns are common.  The applications should be written to only reserve and close connections as needed but multiple statements, if needed, should be done in one reservation (don’t get/close more often than necessary).  This means that the size of the pool is likely to be significantly smaller then the number of users.   If possible, you can pick a size and see how it performs under simulated or real load.  There is a high-water mark statistic (ActiveConnectionsHighCount) that tracks the maximum connections concurrently used.  In general, you want the size to be big enough so that you never run out of connections but no bigger.   It will need to deal with spikes in usage, which is where shrinking after the spike is important.  Of course, the database capacity also has a big influence on the decision since it’s important not to overload the database machine.  Planning also needs to happen if you are running in a Multi-Data Source or Active GridLink configuration and expect that the remaining nodes will take over the connections when one of the nodes in the cluster goes down.  For XA affinity, additional headroom is also recommended.  In summary, setting initial and maximum capacity to be the same may be simple but there are many other factors that may be important in making the decision about sizing.

    Read the article

  • Convert Adsense earnings into Adwords

    - by dmytrivv
    Does anybody know how to convert Adsense earnings into Adwords? Basically, with placing Adsense banners on website, webmaster collects some "potential", or lets say - "active", but its automatically means = money + taxes + other routine work So, I'm wondering if it can be somehow converted into Adwords "potential" and spend again for website need. Theoretically, its just Ads Exchange. But, beauty of Adsense and Adwords is that both platforms have pretty solid clients databases. Any guess how it can be solved? please ...

    Read the article

  • How to handle status columns in designing tables

    - by altsyset
    How to handle multiple statuses for a table entry, for example an item table may have an active, inactive, fast moving, and/or batch statuses. And I wanted to handle them in single column with VARCHAR type. Also I might set each of those attributes as a boolean with different columns. But I am not sure what consequences this might lead to. So if you have experienced such situations which one would be the best way to handle it?

    Read the article

  • Screen blink twice every 10 seconds on ubuntu 12.04

    - by Erik
    On 12.04 64-bit, about every 5 seconds my screen blinks twice. Even during installation of Ubuntu from CD, this happens during the complete process. I had no problems with earlier Ubuntu versions (earlier version was 10.04LTS 64-bit) System specs: I7-2600K MSI 7681 Motherboard 16 GB RAM 2 x Nvidia 560 card SLI (only 1 screen on 1 card active during install process) This flickering is driving me crazy, please help.

    Read the article

  • Warming up with GWB ...

    - by lavanyadeepak
    Warming up with GWB ... I had been wishing to blog @GWB for a while but each time I try to register something or other preempted me away from it. On Saturday last I was little free and hence just thought I would sit and register for the same. Thanks to Jeff for helping me in setting up my account and starting to blog at GWB... I would endeavor to support through this platform active troubleshooting tips, problems and solutions to realtime business queries.

    Read the article

  • Sie haben es so gewollt ...

    - by cjandaus
    Nach zahlreichen Gesprächen mit Oracle Partnern und Kunden, die ihre Oracle Datenbanken auf Microsoft Windows betreiben oder .NET Anwendungen auf Basis von Oracle entwickeln, komme ich dem allgemeinen Wunsch nach und starte einen dedizierten und deutschsprachigen Blog zur Oracle Integration mit Windows, .NET, Active Directory, SharePoint und SQL Server. Dass diese Art des Informationsaustausches von Ihnen bevorzugt wird, ist nicht zuletzt auch eines der Ergebnisse unserer Umfrage auf der DOAG Konferenz 2012. Ihr Claus Jandausch

    Read the article

  • How to customize web app template admintasia? [closed]

    - by Balaji
    The below is my requirement, Login page Login page for all To search whether a user-id & password are a valid or not. To identify whether the user is of which category, namely, Admin, Manager, User. Redirect the page accordingly for respective user with their privilege. Admin - Manager – User Forgot password, Get username of email address and send the credential by validating the user input. Login & Operations Admin Display all submitted forms by admin, manager and user Tabs – Submissions, Mange form & Manage users. Submissions There must be a ‘sort’, listing, admin, manager and user. Username column should hyper link to edit the user account There must be a ‘sort’ option as ‘ALL’ while this option is chosen; the admin must be capable to view, as below, If Admin selects ‘admin’ from dropdown all submitted forms by admin user accounts should display and this operation is similar for the manager account as above. Manage forms, Agent Name, Credit Site, Lenders, Type of Loan, No Scores and Type Of Card Add, edit, update, delete Active and inactive Always display active records. Manage users, Create a user, User account type, (Admin or Manager or User) User email option Edit & update user, Change username Prompt: are you sure? Change password Prompt: are you sure? Delete user Prompt: are you sure you want to delete? Edit – value – this value should be updated in the common form used by all type of users. Manager Display all submitted forms by managers and users. Submissions and Manage users, Submissions Operations Admin Create filter values, admin, manager and user. Edit - filter values, admin, manager and user. Delete filter values, admin, manager and user. View. Manager Create a user only. View forms. User view and/ or submit form only Logout Log out for all. Prompt: Are you sure you want to log-out. I have downloaded adminstasia. How do I customize this template for the above requirement? The installation is same alike if you check this URL, http://www.admintasia.com/demo/

    Read the article

  • Is there an official Ubuntu free technical support team?

    - by João Pinto
    I have found that there is an "Ubuntu Support Team" at https://launchpad.net/~ubuntu-helpteam but I am not sure it's official or active. Please note that I am not referring to bug fixing support, I am referring to the broader OS support, with people available to engage users needing support with a problem and drive it to a proper resolution. Is there an official team for this purpose with a clear scope and activity plan ?

    Read the article

  • Behind the Code: The Analytics Mobile SDK

    Behind the Code: The Analytics Mobile SDK The new Google Analytics Mobile SDK empowers Android and iOS developers to effectively collect user engagement data from their applications to measure active user counts, user geography, new feature adoption and many other useful metrics. Join Analytics Developer Program Engineer Andrew Wales and Analytics Software Engineer Jim Cotugno for an unprecedented look behind the code at the goals, design, and architecture of the new SDK to learn more about what it takes to build world-class technology. From: GoogleDevelopers Views: 0 1 ratings Time: 30:00 More in Science & Technology

    Read the article

  • Programmatically Getting Name of Front-most (currently running) application in Unity

    - by NHDaly
    I am trying to write a script that executes differently depending on the currently active program, and I am wondering if there is any way to find this programatically. For example, I come from the Mac world, and in Apple's Applescript you can do the following: set appPath to the path to the frontmost application set appName to the name of file appPath and that will give you the name of the currently running application. Is there anything similar that I can do in ubuntu-land? Thanks!

    Read the article