  • configuring USB modem( Huawei EC156) in ubuntu 13.10

    - by user205427
    I am facing difficulty in installing my USB modem in Ubuntu 13.10. Contrary to what many have suggested,it does not get detected automatically, nor does setting a new connection help. USB Device is listed in lsusb, but not under network manager or Devices, it is detected as a CD-ROM, what I understood from the web was that usb-modeswitch can be used to switch it to a USB device. Even 'Enable Mobile Broadband' option is not shown in network manager. What was interesting is when I start laptop with windows 7 and use the USB modem and after that restart with Ubuntu, both Enable Broadband and the mobile broadband connection can be seen. Sadly, internet connection could not be installed. I tried using USB-modeswitch command as suggested somewhere, but it does not seem to work. Following is the message. Take all parameters from the command line * usb_modeswitch: handle USB devices with multiple modes * Version 2.0.1 (C) Josua Dietze 2013 * Based on libusb1/libusbx ! PLEASE REPORT NEW CONFIGURATIONS ! DefaultVendor= 0x12d1 DefaultProduct= 0x1505 HuaweiMode=1 NeedResponse=0 InquireDevice enabled (default) Look for default devices ... found USB ID 8087:0020 found USB ID 1d6b:0002 found USB ID 0461:4db6 found USB ID 12d1:1505 vendor ID matched product ID matched found USB ID 138a:0007 found USB ID 03f0:231d found USB ID 8087:0020 found USB ID 1d6b:0002 Found devices in default mode (1) Access device 005 on bus 001 Get the current device configuration ... OK, got current device configuration (1) Use interface number 0 Use endpoints 0x08 (out) and 0x87 (in) Inquire device details; driver will be detached ... Looking for active driver ... OK, driver detached INQUIRY message failed (error -9) USB description data (for identification) ------------------------- Manufacturer: HUA?WEI TECHNOLOGIES Product: HUAWEI Mobile Serial No.: ??????????????????? ------------------------- Send old Huawei control message ... -> Run lsusb to note any changes. Bye! I am stuck with this problem for 4 days now, any help would be appreciated

    Read the article

  • Can't start webcam for google video services

    - by wisemonkey
    I've got Ubuntu 11.10 64 bit and have installed the google video chat plugin. However webcam doesn't seem to work (black screen -- no video at all). For cheese it works but shows really bad (black and white kinda) image. Following some link I installed guvcview if I start it then image looks neat. Any suggestions on how can it be fixed? If it helps I've tried the solution: $ sudo mv /opt/google/talkplugin/GoogleTalkPlugin /opt/google/talkplugin/GoogleTalkPlugin.old $ sudo gedit /opt/google/talkplugin/GoogleTalkPlugin and putting following lines in: #!/bin/sh LD_PRELOAD=/usr/lib32/libv4l/v4l1compat.so /opt/google/talkplugin/GoogleTalkPlugin.old OR #!/bin/sh LD_PRELOAD=/usr/lib/x86_64-linux-gnu/libv4l/v4l1compat.so /opt/google/talkplugin/GoogleTalkPlugin.old Cause I've both files. Finally $sudo chmod +x /opt/google/talkplugin/GoogleTalkPlugin.old I closed and reopened chrome then started gmail tried video call -- black screen :-/ Ok so today finally google+ provided me with trouble shoot link and advised me: The plug-in won't install If you're having trouble installing the plug-in, or are receiving a message asking you to reinstall it, you should check to make sure your configuration is right. To do so simply: Check to make sure the Google Talk Plugin Video Accelerator and Google Talk NPAPI Plugin are enabled. If you're using Chrome you can type about:plugins in your browser to display your plug-ins. Make sure you're not using Internet Explorer 64-bit (this is a browser version that is 64 bit as opposed to 32 bit). Ensure that you don't have any "click to run" extensions enabled. If you're still experiencing this issue after checking your configuration you can follow these steps: Refresh the browser page. Close any running Google Talk plug-in processes. Close all open and running browser processes. Restart your computer. Uninstall and then reinstall the plug-in. Try a different browser such as Google Chrome or Mozilla Firefox. I looked in about:plugins for chrome and firefox: I don't have Google Talk NPAPI Plugin, does that matter? and I thought its installed with google talk plugin or no?

    Read the article

  • Bad archive mirror using PXE boot method

    - by user11566
    I'm trying to automatically install Ubuntu on a client PC by using the PXE BOOT method....my Objectives are below: I am following the steps given in this link installation using PXE BOOT the server will have a KICKSTART config file which contains the parameters for the OS installation and the files which are required for the OS installations. the client will have to detect this configuration along with the setup files and complete the installation without any input from the user. In my server I have installed DHCP3-server,Apache2 and TFTP to help me with the installation. I have nearly achieved my first objective, I am able to boot my client using the files stored in the server but during the installation stage it is asking me to CHOOSE A MIRROR OF UBUNTU ARCHIVE I gave the server's IP address and the path in the server where the files are located but then its giving me this error BAD ARCHIVE MIRROR So is it possible that instead of downloading all the files from the internet and storing them on my disk can I use the files which comes with the UBUNTU-CD, and how to store these files in what format (should I zip them) on the disk? secondly I am also generating the ks.cfg which I wanted to give to the client for automatic installation of the OS. So how should the configuration file be given to the installation process?

    Read the article

  • Wordpress blog website apache and IIS subdirectory

    - by Philippe
    The issue is this : Our company has a website hosted on an IIS server. I have recently been given the task to configure a WordPress server for an eventual WordPress blog so that our social media employee could test and see how it works. This was completed successfully and easily on a new server and on a WAMP configuration. The website was published as wordpress.domain.com and works fine. HOWEVER! I have now been requested to ensure that the soon-to-go-online blog would be accessible through the address domain.com/blog. Is there a way to modify the original company website and simple redirect the /blog to the Apache WordPress website? If not, is there a way to transfer the wordpress.domain.com on the IIS server hosting the main website and keep the configuration? Is there a better solution that I haven't thought about (probably)? If so, what would you all suggest?

    Read the article

  • How do I get an application to appear as a choice in update-alternatives?

    - by Jay
    I separately installed the Firefox Beta and Alpha channels, and have desktop configuration files pointing to them in ~/.local/share/applications. However, stable Firefox is being used as my default browser by the system. (Firefox Beta used to be used until I messed with the "Default Applications" in System Settings, where it is not listed.) I tried running sudo update-alternatives --config x-www-browser to manually change it, but it's only recognizing Chromium and Firefox (stable) and showing them as a choice. What can I do to get custom desktop configuration files in ~/.local/share/applications to be seen as default alternatives? I think I may have to fiddle with the desktop config files, or with mimeinfo.cache or mimeapps.list? Running Oneiric. Here is the content of the firefox-beta.desktop file I created: [Desktop Entry] Name=Firefox Beta Exec=firefox-beta -P Beta -no-remote Icon=firefox Terminal=false X-MultipleArgs=false Type=Application StartupNotify=true StartupWMClass=Firefox Categories=GNOME;GTK;Network;WebBrowser; Comment[en_US]=Firefox Beta Channel MimeType=text/html;text/xml;application/xhtml+xml;application/xml;application/vnd.mozilla.xul+xml;application/rss+xml;application/rdf+xml;image/gif;image/jpeg;image/png;x-scheme-handler/http;x-scheme-handler/https;x-scheme-handler/ftp;x-scheme-handler/chrome;video/webm; Name[en_US]=Firefox Beta [NewWindow Shortcut Group] Name=Open a New Window Exec=firefox-beta -new-window about:blank TargetEnvironment=Unity

    Read the article

  • Howto configure openSuSE firewall to route local traffic to local ports

    - by Eduard Wirch
    I have openSUSE 11.3 installed. I'm using the openSUSE firewall configuration mechanism (/etc/sysconfig/SuSEfirewall2). I have a http server application running on port 8080. I want the http service to be accessible using port 80. I created a redirect rule usign: FW_REDIRECT="0/0,0/0,tcp,80,8080" This works fine for every request coming from external. But it doesn't for local requests. (example: wget http://myserver/) Is there a way how I can tell the firewall to redirect local requests addressed for 80 to port 8080? (using the SUSE firewall configuration file)

    Read the article

  • Exchange 2010 Deployment Notes - ISA 2004 Server Issue

    - by BWCA
    An interesting ISA 2004 tidbit … While we were setting up our Exchange 2010 ActiveSync environment, we encountered a problem where we could not successfully telnet over port 443 from one of our ISA 2004 Servers to our Exchange 2010 Client Access Server Array. When we tried to telnet over port 443 from the ISA Server to the Client Access Server Array name, we would get a “Could not open connection to the host on port 443: Connect failed” error message. Also, when we used portqry over port 443 from the ISA Server to the Client Access Server Array name, we would get a “Error opening socket: 10065” and “No route to host” error messages. It was odd because we did not have any problems with using ping or tracert from the ISA Server to the Client Access Server Array and our firewall firewall policy was allowing 443 traffic to pass through. After some troubleshooting, we were able to telnet and use portqry over port 443 successfully if we stopped the Microsoft Firewall service on the ISA 2004 Server.  So, it was strictly a problem with ISA.  Eventually, we were able to isolate the problem to a ISA 2004 Server System Policy setting as shown below (to modify the System Policy, right-click Firewall Policy and click Edit System Policy). Under the Diagnostics Services – HTTP Connectivity verifiers Configuration Group, you need to enable the configuration group under the General tab to resolve the problem.  After we enabled the setting, we no longer had a problem.

    Read the article

  • Exim: How to turn off DKIM for forwarded mail?

    - by Andrew
    I have DKIM configured in Exim for outgoing mail, as per the documentation. Exim signs all outgoing mail. But some of that outgoing mail is forwarded, thanks to a users .forward file. This is a problem for me, because some of those messages are spam (my exim configuration does not do any verification) and I don't want to take responsibility for them. But I can't figure out how to configure Exim not to sign these messages. My configuration is basically the Debian Squeeze default, with a few DKIM_* macros set. I can post more details, but I think seeing any example of conditional DKIM signing would set me right.

    Read the article

  • apt-get failed install of libg15, all package management is failing

    - by Stifle
    I was trying to get my Logitech G510 keyboard's back-lights working so I went into the Synaptic Package Manager and marked LibG15, G15daemon, and all the other associated packages. Synaptic reported a failed install. Now all Package management is failing due to libg15 being "halfway installed." Some commands I have tried to fix the problem follow. . . root@bt:~# apt-get upgrade Reading package lists... Done Building dependency tree Reading state information... Done E: The package libg15 needs to be reinstalled, but I can't find an archive for it. root@bt:~# sudo apt-get autoremove Reading package lists... Done Building dependency tree Reading state information... Done E: The package libg15 needs to be reinstalled, but I can't find an archive for it. root@bt:~# sudo apt-get -f purge libg15 Reading package lists... Done Building dependency tree Reading state information... Done E: The package libg15 needs to be reinstalled, but I can't find an archive for it. root@bt:~# sudo dpkg --configure -a dpkg: dependency problems prevent configuration of g15macro: g15macro depends on g15daemon; however: Package g15daemon is not configured yet. dpkg: error processing g15macro (--configure): dependency problems - leaving unconfigured dpkg: dependency problems prevent configuration of g15stats: g15stats depends on g15daemon; however: Package g15daemon is not configured yet. dpkg: error processing g15stats (--configure): dependency problems - leaving unconfigured Errors were encountered while processing: g15macro g15stats I'm not too computer savvy. Any help would be much appreciated!!! Note: I'm using Ubuntu 10.04 under Backtrack 5 R3.

    Read the article

  • I used "autoconf6" (used to configure IPV6) on an AIX 6 target and I don't know how to change it back.

    - by newtoaix
    So I got curious and ran autoconf6 and now I can't figure out how to undo the changes that were made. I have tried using smitty to modify the en0 interface but have had no luck getting it back to it's old configuration. The old configuration of the aix 6 box was: en0: flags=5e080863,c0 inet 10.10.30.212 netmask 0xffffff00 broadcast 10.10.30.255 tcp_sendspace 131072 tcp_recvspace 65536 lo0: flags=e08084b inet 127.0.0.1 netmask 0xff000000 broadcast 127.255.255.255 inet6 ::1/0 tcp_sendspace 131072 tcp_recvspace 131072 rfc1323 1 then I ran autoconf6 and it was changed to: en0: flags=5e080863,c0 inet 10.10.30.212 netmask 0xffffff00 broadcast 10.10.30.255 inet6 fe80::214:5eff:fe96:b806/64 tcp_sendspace 131072 tcp_recvspace 65536 sit0: flags=8100041 inet6 ::10.10.30.212/96 lo0: flags=e08084b inet 127.0.0.1 netmask 0xff000000 broadcast 127.255.255.255 inet6 ::1/128 tcp_sendspace 131072 tcp_recvspace 131072 rfc1323 1 Any help would be awesome.

    Read the article

  • Trouble migrating Joomla from Linux to Windows server

    - by Matt
    I'm having some trouble migrating a Joomla website from a Linux server to a Windows server. The database came over fine, Besides that, all I've done is download all the files from the current site, and change configuration.php so the log and tmp directories show "./tmp/" and "./logs/" I keep having an error in the PHP log stating PHP Fatal error: Class 'JTable' not found I've downloaded the site multiple times now, and I'm convinced this is a configuration problem, and not a missing file problem. I've even tried installing a mod for backup on the linux box to try and migrate the site, but sadly the mod had problems installing. The new server is running IIS 7.5 on Windows Web Server. PHP 5.2.14 and MySQL

    Read the article

  • Option and command keys in OSX are swapped and keyboard preferences do not set them back.

    - by bikesandcode
    On my MacBook pro, I occasionally use external keyboards, generally Windows ones and things have been fine. Yesterday, I plugged in a new one, remapped the command/option keys so the windows/alt keys were in the same configuration, again, nothing new here. However, this time when I unplugged the USB keyboard, the laptops option/command keys remained switched. More annoying is that if I go into the System Preferences - Keyboards - Modifier keys, remapping the keys to actions does not work. I can use the drop downs to disable any specific keys, but switching the behaviours does nothing. (Cmd/Option obvious, tried remapping anything to caps lock and a few other combinations, no joy. Restore defaults set the configuration to what I'd expect, but the settings are evidently ignored.) So: Any ideas?

    Read the article

  • Windows Server 2012 - SSL Cypher Suite Order Not Long Enough

    - by Sam
    I want to re-order the cypher suites on our new Windows Server 2012 box to help mitigate the BEAST vulnerability for our clients. I went to Local Group Policy => Computer Configuration => Administrative Templates => Network => SSL Configuration Settings, opened SSL Cypher Suite Order, enabled it, and copied the values from the SSL Cypher Suites textbox. I pasted them into notepad, re-ordered them, then copied+pasted them back into the SSL Cypher Suites textbox. However, the box isn't long enough to hold them all, despite the fact that the length didn't change. I would have to drop the last 3 cyphers (SSL_CK_DES_192_EDE3_CBC_WITH_MD5,TLS_RSA_WITH_NULL_SHA256,TLS_RSA_WITH_NULL_SHA) in order for it to fit. Should I just drop them? Other ideas?

    Read the article

  • Problem with Xen, xvda and sda

    - by Javier J. Salmeron Garcia
    I am creating a cloud for my university using Eucalyptus with Xen (PCs have Debian Squeeze 64 bit installed). I have a problem with the following guest configuration: # # Configuration file for the Xen instance evenmorefinalfoo, created # by xen-tools 4.2 on Thu May 26 11:03:06 2011. # # # Kernel + memory size # kernel = '/boot/vmlinuz-2.6.32-5-xen-amd64' ramdisk = '/boot/initrd.img-2.6.32-5-xen-amd64' vcpus = '1' memory = '128' # # Disk device(s). # root = '/dev/sda2 ro' disk = [ 'file:/home/xen/domains/evenmorefinalfoo/disk.img,sda2,w', 'file:/home/xen/domains/evenmorefinalfoo/swap.img,sda1,w', ] As you can see, the disk and swap images are meant to be mounted on sda1 and sda2. However, when I start the guest, these are mounted on xvda1 xvda2, provoking an error. Is there anything that I can do about that? It seems like it is a Xen error. Thank you in advance,

    Read the article

  • Bacula Director and Storage in LAN

    - by B14D3
    I have two networks LAN and DMZ.. Machines in DMZ are accesible from internet ( only over http). In LAN I have servers that see all LAN and all DMZ machines but machinse from DMZ don't see any LAN servers. Machines in LAN have access only to all LAN and DMZ, no direct access to internet and no access from internet. DMZ <------ LAN DMZ ----X--->LAN I'm planning to configure Bacula as major backup system. My plan is to install Bacula Director and Storage deamon on the same server in LAN for safety reasons. So my question is: Will this configuration work, is it posible for bacula director and storage deamon installed on server in LAN to makes backup servers that are in my DMZ? Or in this network configuration Bacula should be in DMZ? (If yes will I can backup with it servers in LAN ?)

    Read the article

  • APC Not Enabled (WHM on CentOS)

    - by gamerzfuse
    I know this questions has been beat to death, but I've read almost all the responses and it hasn't solved my issue. I installed APC (no noted errors), I told PHP.ini to enable it and I made sure I am running PHP in FastCGI with SuExec turned off. Still I have no go. PHP / suEXEC Configuration Default PHP Version (.php files) 5 PHP 5 Handler fcgi PHP 4 Handler none Apache suEXEC off Apache Ruid2 off php.ini Configuration Alternative PHP Cache apc.enabled Alternative PHP Cache apc.shm_segments Alternative PHP Cache apc.shm_size When I run the APC.php file I get this message: No cache info available. APC does not appear to be running.

    Read the article

  • "Enable Wireless" option is disabled in network settings

    - by silenTK
    I'm using Ubuntu 11.10 (dual booted with Windows 7) but I'm unable to access Internet wireless even though I can do so on Windows 7. The output for rfkill list all is given below: rfkill list all 0: brcmwl-0: Wireless LAN Soft blocked: no Hard blocked: yes 1: hp-wifi: Wireless LAN Soft blocked: no Hard blocked: no The output for sudo lshw -C network *-network DISABLED is: description: Wireless interface product: BCM4313 802.11b/g/n Wireless LAN Controller vendor: Broadcom Corporation physical id: 0 bus info: pci@0000:02:00.0 logical name: eth1 version: 01 serial: 11:11:11:11:11:11 width: 64 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list ethernet physical wireless configuration: broadcast=yes driver=wl0 driverversion=5.100.82.38 latency=0 multicast=yes wireless=IEEE 802.11 resources: irq:16 memory:c2500000-c2503fff *-network description: Ethernet interface product: RTL8101E/RTL8102E PCI Express Fast Ethernet controller vendor: Realtek Semiconductor Co., Ltd. physical id: 0 bus info: pci@0000:03:00.0 logical name: eth0 version: 05 serial: 22:22:22:22:22:22 size: 100Mbit/s capacity: 100Mbit/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress msix vpd bus_master cap_list ethernet physical tp mii 10bt 10bt-fd 100bt 100bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=r8169 driverversion=2.3LK-NAPI duplex=full firmware=rtl_nic/rtl8105e-1.fw latency=0 link=yes multicast=yes port=MII speed=100Mbit/s resources: irq:42 ioport:3000(size=256) memory:c0404000-c0404fff memory:c0400000-c0403fff Broadcom STA wireless driver is installed, activated, and currently in use. My laptop is a HP-Pavilion-g6-1004tx. My hardware switch is on. Enable Wireless option is also disabled in network settings.

    Read the article

  • Automated backups for Windows Azure SQL Database

    - by Greg Low
    One of the questions that I've often been asked is about how you can backup databases in Windows Azure SQL Database. What we have had access to was the ability to export a database to a BACPAC. A BACPAC is basically just a zip file that contains a bunch of metadata along with a set of bcp files for each of the tables in the database. Each table in the database is exported one after the other, so this does not produce a transactionally-consistent backup at a specific point in time. To get a transactionally-consistent copy, you need a database that isn't in use.The easiest way to get a database that isn't in use is to use CREATE DATABASE AS COPY OF. This creates a new database as a transactionally-consistent copy of the database that you are copying. You can then use the export options to get a consistent BACPAC created.Previously, I've had to automate this process by myself. Given there was also no SQL Agent in Azure, I used a job in my on-premises SQL Server to do this, using a linked server configuration.Now there's a much simpler way. Windows Azure SQL Database now supports an automated export function. On the Configuration tab for the database, you need to enable the Automated Export function. You can configure how often the operation is performed for you, and which storage account will be used for the backups.It's important to consider the cost impacts of this as well. You are charged for how ever many databases are on your server on a given day. So if you enable a daily backup, you will double your database costs. Do not schedule the backups just before midnight UTC, as that could cause you to have three databases each day instead of one.This is a much needed addition to the capabilities. Scott Guthrie also posted about some other notable changes today, including a preview of a new premium offering for SQL Database. In addition to the Web and Business editions, there will now be a Premium edition that has reserved (rather than shared) resources. You can read about it all in Scott's post here: http://weblogs.asp.net/scottgu/archive/2013/07/23/windows-azure-july-updates-sql-database-traffic-manager-autoscale-virtual-machines.aspx

    Read the article

  • Trying to install Canon LBP7750Cdn driver on Ubuntu 12.04

    - by Gideon
    I'n new to Ubuntu/Linux and had significant difficulties while attempting to configure my printer to work. The automatic driver pairing wizard which Ubuntu uses to identify and install the appropriate drivers did not find my printer's driver. I managed to get it to print when I manually select the generic configuration and checked the PCL6 configuration. However, the printer driver wizard does provide a list of Canon printers and actually do specify my printer as LBP7750C (minus the "dn" at the end, I'm assuming its because duplex ability and networking is not present on all the models - I'm not sure if this could be the source of the problem), but in selecting this option and trying to print I receive this message: Idle - /usr/lib/cups/filter/foomatic-rip failed I searched for this similar problem which other users might have encountered, but while there where plenty of such cases, they all had different resolutions and were all related to HP printers. Canon actually do provide a driver for my printer, but it comes with no installation instructions unless you consider yourself an experienced CUPS guru. Seriously. If anyone can help me solve this foomatic-rip failed problem I'd be really grateful - and I'm sure many other folks too. [BTW, can't Canonical fix this type of thing for the next Ubuntu release? - I't seems like a small problem but it causes many problems and countles hours of production time loss.] Thanks in advance.

    Read the article

  • Discs in DVD Drive not being read

    - by I Heart Ubuntu
    Does anyone have an experience with Ubuntu that is no longer reading discs in the DVD drive? This is my first time Ubuntu does not see the disc :| The disc is fine and works on my other Ubuntu computers. The drive is there and powered. I can even type in eject in a terminal and the drive will open. Using the command: sudo lshw -C disk I am able to see info about my drive too. Actually BOTH of my internal DVD drives cannot read discs anymore. If the output is not readable below, here is the info in pastebin. http://pastebin.com/GqqSCTPw *-cdrom:0 description: DVD writer product: DVD_RW ND-3500AG vendor: _NEC physical id: 0.0.0 bus info: scsi@0:0.0.0 logical name: /dev/cdrom1 logical name: /dev/cdrw1 logical name: /dev/dvd1 logical name: /dev/dvdrw1 logical name: /dev/scd0 logical name: /dev/sr0 version: 2.1B serial: [_NEC DVD_RW ND-3500AG2.1B06022300BT-LIGGY capabilities: removable audio cd-r cd-rw dvd dvd-r configuration: ansiversion=5 status=nodisc *-cdrom:1 description: DVD-RAM writer product: CDDVDW SH-S222A vendor: TSSTcorp physical id: 0.1.0 bus info: scsi@0:0.1.0 logical name: /dev/cdrom logical name: /dev/cdrw logical name: /dev/dvd logical name: /dev/dvdrw logical name: /dev/scd1 logical name: /dev/sr1 version: SB01 capabilities: removable audio cd-r cd-rw dvd dvd-r dvd-ram configuration: ansiversion=5 status=nodisc

    Read the article

  • Adaptec 5805 not recognized after reboot

    - by Rakedko ShotGuns
    After rebooting the system, the controller is not recognized. It only works if the computer is shut down and turned off. I have recently updated the firmware to "Adaptec RAID 5805 Firmware Build 18948". How do I fix the problem? Configuration summary --------------------------- 1. Server name.....................raid_test Adaptec Storage Manager agent...7.31.00 (18856) Adaptec Storage Manager console.7.31.00 (18856) Number of controllers...........1 Operating system................Windows Configuration information for controller 1 ------------------------------------------------------- Type............................Controller Model...........................Adaptec 5805 Controller number...............1 Physical slot...................2 Installed memory size...........512 MB Serial number...................8C4510C6C9E Boot ROM........................5.2-0 (18948) Firmware........................5.2-0 (18948) Device driver...................5.2-0 (16119) Controller status...............Optimal Battery status..................Charging Battery temperature.............Normal Battery charge amount (%).......37 Estimated charge remaining......0 days, 16 hours, 12 minutes Background consistency check....Disabled Copy back.......................Disabled Controller temperature..........Normal (40C / 104F) Default logical drive task priority High Performance mode................Dynamic Number of logical devices.......1 Number of hot-spare drives......0 Number of ready drives..........0 Number of drive(s) assigned to MaxCache cache0 Maximum drives allowed for MaxCache cache8 MaxCache Read Cache Pool Size...0 GB NCQ status......................Enabled Stay awake status...............Disabled Internal drive spinup limit.....0 External drive spinup limit.....0 Phy 0...........................No device attached Phy 1...........................No device attached Phy 2...........................No device attached Phy 3...........................1.50 Gb/s Phy 4...........................No device attached Phy 5...........................No device attached Phy 6...........................No device attached Phy 7...........................No device attached Statistics version..............2.0 SSD Cache size..................0 Pages on fetch list.............0 Fetch list candidates...........0 Candidate replacements..........0 69319...........................31293 Logical device..................0 Logical device name............. RAID level......................Simple volume Data space......................148,916 GB Date created....................09/19/2012 Interface type..................Serial ATA State...........................Optimal Read-cache mode.................Enabled Preferred MaxCache read cache settingEnabled Actual MaxCache read cache setting Disabled Write-cache mode................Enabled (write-back) Write-cache setting.............Enabled (write-back) Partitioned.....................Yes Protected by hot spare..........No Bootable........................Yes Bad stripes.....................No Power Status....................Disabled Power State.....................Active Reduce RPM timer................Never Power off timer.................Never Verify timer....................Never Segment 0.......................Present: controller 1, connector 0, device 0, S/N 9RX3KZMT Overall host IOs................99075 Overall MB......................4411203 DRAM cache hits.................71929 SSD cache hits..................0 Uncached IOs....................29239 Overall disk failures...........0 DRAM cache full hits............71929 DRAM cache fetch / flush wait...0 DRAM cache hybrid reads.........3476 DRAM cache flushes..............-- Read hits.......................0 Write hits......................0 Valid Pages.....................0 Updates on writes...............0 Invalidations by large writes...0 Invalidations by R/W balance....0 Invalidations by replacement....0 Invalidations by other..........0 Page Fetches....................0 0...............................0 73..............................10822 8...............................3 46138...........................4916 27184...........................15226 20875...........................323 16982...........................1771 1563............................5317 1948............................2969 Serial attached SCSI ----------------------- Type............................Disk drive Vendor..........................Unknown Model...........................ST3160815AS Serial Number...................9RX3KZMT Firmware level..................3.AAD Reported channel................0 Reported SCSI device ID.........0 Interface type..................Serial ATA Size............................149,05 GB Negotiated transfer speed.......1.50 Gb/s State...........................Optimal S.M.A.R.T. error................No Write-cache mode................Write back Hardware errors.................0 Medium errors...................0 Parity errors...................0 Link failures...................0 Aborted commands................0 S.M.A.R.T. warnings.............0 Solid-state disk (non-spinning).false MaxCache cache capable..........false MaxCache cache assigned.........false NCQ status......................Enabled Phy 0...........................1.50 Gb/s Power State.....................Full rpm Supported power states..........Full rpm, Powered off 0x01............................113 0x03............................98 0x04............................99 0x05............................100 0x07............................83 0x09............................75 0x0A............................100 0x0C............................99 0xBB............................100 0xBD............................100 0xBE............................61 0xC2............................39 0xC3............................69 0xC5............................100 0xC6............................100 0xC7............................200 0xC8............................100 0xCA............................100 Aborted commands................0 Link failures...................0 Medium errors...................0 Parity errors...................0 Hardware errors.................0 SMART errors....................0 End of the configuration information for controller 1

    Read the article

  • postfix-dovecot email sending works with squirrel mail but not with Thunderbird?

    - by Mark S.
    I have setup an intranet email system using postfix, dovecot and squirrel mail, Which is working fine, I can send and receive mail to all users on the system. I presume that the issue is in the postfix configuration, because when I configure Thunderbird to send mail I am getting the following error: An error occurred while sending mail. The mail server responded: 4.1.8 <[email protected]>: Sender address rejected: Domain not found. Please check the message recipient [email protected] and try again. Also here is the relevant syslog entries: NOQUEUE: reject: RCPT from host1.intranetdomain.com [More Information] [192.168.11.1 [More Information] ]: 450 4.1.8 <[email protected]>: Sender address rejected: Domain not found; from=<[email protected]> to=<[email protected]> proto=ESMTP helo=<[127.0.0.1 [More Information] ]> I have configured MX records on the DNS server and they respond appropriately when I query them for those MX records, so I do not think that is the issue. I think that my issue is caused by the default configuration of: smtpd_recipient_restrictions = reject_unknown_sender_domain, reject_unknown_recipient_domain, reject_unauth_pipelining, permit_mynetworks, permit_sasl_authenticated, reject_unauth_destination smtpd_sender_restrictions = reject_unknown_sender_domain Since this is on an internal network and it will not be exposed to the internet as a whole which options can I remove safely?

    Read the article

  • Allow from referer for HTTP-basic protected SSL apache site

    - by user64204
    I have an apache site protected by HTTP basic authentication. The authentication is working fine. Now I would like to bypass authentication for users that are coming from a particular website by relying on the HTTP Referer header. Here is the configuration: SetEnvIf Referer "^http://.*.example\.org" coming_from_example_org <Directory /var/www/> Options Indexes FollowSymLinks MultiViews AllowOverride None Deny from all Allow from env=coming_from_example_org AuthName "login required" AuthUserFile /opt/http_basic_usernames_and_passwords AuthType Basic Require valid-user Satisfy Any </Directory> This is working fine for HTTP, but failing for HTTPS. My understanding is that in order to inspect the HTTP headers, the SSL handshake must be completed, but apache wants to inspect the <Directory> directives before doing the SSL handshake, even if I place them at the bottom of the configuration file. Q: How could I workaround this issue? PS: I'm not obsessed with the HTTP referer header, I could use other options that would allow users from a known website to bypass authantication.

    Read the article

  • Chassis fans and power LEDs still work in Hibernate

    - by Jaded
    I have ASRock Z68 Extreme3 Gen3 motherboard recently updated to 2.20 BIOS version. OS is Windows 7 x64. The problem is after that update full hibernation (by that i mean full system power off) stopped working although everything was fine before. Now when I press hibernate, sleep in initiated as usual, monitor goes to sleep, HDD and CPU fan stop spinning, but chassis fans (i have Gigabyte Aurora 3D 570 case with two rear and one front fans) still remain working. Also power leds are lit as if computer is turned on. Tried changing different UEFI settings related to sleep mode, and none of them change above described behaviour. I have "Deep Sleep" (Advanced-South Bridge Configuration) set to "Enabled in S4-S5", "Suspend to RAM" (Advanced-ACPI Configuration) set to "Auto", all fans settings in "H/W Monitor" set to "Auto".

    Read the article

  • Missing driver ASUS PCE-N53 11n N600 PCI-E Adapter

    - by oyse
    I have problems with getting an Asus PCE-N53 11n N600 PCI-E Adapter card to work on my desktop computer. As far as I can tell no drivers are installed for the card. I know I can manually download the drivers directly from Asus, but I would rather not go that route. If there are anyone that knows about any packages or other things I can do to make this work would be much appreciated. Some systems details: $ lsb_release -a No LSB modules are available. Distributor ID: Ubuntu Description: Ubuntu 12.04.1 LTS Release: 12.04 Codename: precise $ sudo lshw -C network *-network description: Ethernet interface product: RTL8111/8168B PCI Express Gigabit Ethernet controller vendor: Realtek Semiconductor Co., Ltd. physical id: 0 bus info: pci@0000:03:00.0 logical name: eth0 version: 06 serial: d4:3d:7e:03:b9:1d size: 100Mbit/s capacity: 1Gbit/s width: 64 bits clock: 33MHz capabilities: pm msi pciexpress msix vpd bus_master cap_list ethernet physical tp mii 10bt 10bt-fd 100bt 100bt-fd 1000bt 1000bt-fd autonegotiation configuration: autonegotiation=on broadcast=yes driver=r8169 driverversion=2.3LK-NAPI duplex=full firmware=rtl8168e-3_0.0.4 03/27/12 ip=192.168.0.173 latency=0 link=yes multicast=yes port=MII speed=100Mbit/s resources: irq:43 ioport:d000(size=256) memory:f2104000-f2104fff memory:f2100000-f2103fff *-network UNCLAIMED description: Network controller product: Ralink corp. vendor: Ralink corp. physical id: 0 bus info: pci@0000:04:00.0 version: 00 width: 32 bits clock: 33MHz capabilities: pm msi pciexpress bus_master cap_list configuration: latency=0 resources: memory:f7100000-f710ffff $ lsmod Module Size Used by nvidia 12319264 51 vesafb 13844 1 snd_hda_codec_hdmi 32474 1 joydev 17693 0 bnep 18281 2 rfcomm 47604 0 bluetooth 180104 10 bnep,rfcomm snd_hda_codec_realtek 224173 1 snd_seq_midi 13324 0 ppdev 17113 0 snd_rawmidi 30748 1 snd_seq_midi usbhid 47199 0 hid 99559 1 usbhid nouveau 774641 0 parport_pc 32866 1 snd_hda_intel 33773 5 ttm 76949 1 nouveau snd_hda_codec 127706 3 snd_hda_codec_hdmi,snd_hda_codec_realtek,snd_hda_intel drm_kms_helper 46978 1 nouveau drm 242038 3 nouveau,ttm,drm_kms_helper snd_seq_midi_event 14899 1 snd_seq_midi snd_hwdep 13668 1 snd_hda_codec snd_seq 61896 2 snd_seq_midi,snd_seq_midi_event i2c_algo_bit 13423 1 nouveau mxm_wmi 12979 1 nouveau wmi 19256 1 mxm_wmi mac_hid 13253 0 snd_pcm 97188 3 snd_hda_codec_hdmi,snd_hda_intel,snd_hda_codec psmouse 97362 0 video 19596 1 nouveau snd_timer 29990 2 snd_seq,snd_pcm snd_seq_device 14540 3 snd_seq_midi,snd_rawmidi,snd_seq snd 78855 20 snd_hda_codec_hdmi,snd_hda_codec_realtek,snd_rawmidi,snd_hda_intel,snd_hda_codec,snd_hwdep,snd_seq,snd_pcm,snd_timer,snd_seq_device serio_raw 13211 0 soundcore 15091 1 snd snd_page_alloc 18529 2 snd_hda_intel,snd_pcm mei 41616 0 lp 17799 0 parport 46562 3 ppdev,parport_pc,lp r8169 62099 0