Search Results

Search found 94 results on 4 pages for 'gbps'.

Page 3/4 | < Previous Page | 1 2 3 4  | Next Page >

  • Apache Prefork Configuration

    - by user1618606
    I'm newbie on VPS configuration. So, I've installed apache, php and mysql and now I need to know how to configure Prefork to optimize Apache. The system configuration is: CPU Cores 2 x 2 Ghz @ 4 Ghz RAM Memory 2304 MB DDR3 Burst Memory 3 GB DDR3 Disk Space 30 GB SSD Bandwidth 3 TB SwitchPort 1 Gbps Actually, after linux, mysql, apache and php, there are 250 MB memory in use. Well, I don't have idea to calculate. I saw in some websistes, some vars like: KeepAlive On KeepAliveTimeout 1 MaxKeepAliveRequests 100 StartServers 15 MinSpareServers 15 MaxSpareServers 15 MaxClients 20 MaxRequestsPerChild 0 or StartServers 2 MaxClients 150 MinSpareThreads 25 MaxSpareThreads 75 ThreadsPerChild 25 MaxRequestsPerChild 0 How I could to do: Prefork or worker? Where and how the vars are placed? In httpd.conf?

    Read the article

  • Multi Thread Rsync Transfer

    - by reefine
    For some reason when running a single rsync command I am getting 1 MB/sec to 2 MB/sec even when I connecting 2 servers both connected to 1 Gbps ports. rsync -v --progress -e ssh /backup/mysqldata/mysql-bin.000199 [email protected]:/secondary/mysqldata/mysqldata/mysql-bin.000199 I have over 800 GB of data to transfer split among 500 or so files all starting with: mysql-bin.000* I've found that running 25-30 rsync simultaneously from seperate SSH windows gets me upwards of 25 MB/sec but it will take me hours to run these all manually. Is there anyway to get the 25 MB/sec from a single rsync command?

    Read the article

  • Weighted round robins via TTL - possible?

    - by Joe Hopfgartner
    I currently use DNS round robin for load balancing, which works great. The records look like this (I have a ttl of 120 seconds) ;; ANSWER SECTION: orion.2x.to. 116 IN A 80.237.201.41 orion.2x.to. 116 IN A 87.230.54.12 orion.2x.to. 116 IN A 87.230.100.10 orion.2x.to. 116 IN A 87.230.51.65 I learned that not every ISP / device treats such a response the same way. For example some DNS servers rotate the addresses randomly or always cycle them through. Some just propagate the first entry, others try to determine which is best (regionally near) by looking at the ip address. However if the userbase is big enough (spreads over multiple ISPs etc) it balances pretty well. The discrepancies from highest to lowest loaded server hardly every exceeds 15%. However now I have the problem that I am introducing more servers into the systems, that not all have the same capacities. I currently only have 1gbps servers, but I want to work with 100mbit and also 10gbps servers too. So what I want is I want to introduce a server with 10 GBps with a weight of 100, a 1 gbps server with a weight of 10 and a 100 mbit server with a weight of 1. I used to add servers twice to bring more traffic to them (which worked nice. the bandwidth doubled almost.) But adding a 10gbit server 100 times to DNS is a bit rediculous. So I thought about using the TTL. If I give server A 240 seconds ttl and server B only 120 seconds (which is about about the minimum to use for round robin, as a lot of dns servers set to 120 if a lower ttl is specified.. so i have heard) I think something like this should occour in an ideal scenario: first 120 seconds 50% of requests get server A -> keep it for 240 seconds. 50% of requests get server B -> keep it for 120 seconds second 120 seconds 50% of requests still have server A cached -> keep it for another 120 seconds. 25% of requests get server A -> keep it for 240 seconds 25% of requests get server B -> keep it for 120 seconds third 120 seconds 25% will get server A (from the 50% of Server A that now expired) -> cache 240 sec 25% will get server B (from the 50% of Server A that now expired) -> cache 120 sec 25% will have server A cached for another 120 seconds 12.5% will get server B (from the 25% of server B that now expired) -> cache 120sec 12.5% will get server A (from the 25% of server B that now expired) -> cache 240 sec fourth 120 seconds 25% will have server A cached -> cache for another 120 secs 12.5% will get server A (from the 25% of b that now expired) -> cache 240 secs 12.5% will get server B (from the 25% of b that now expired) -> cache 120 secs 12.5% will get server A (from the 25% of a that now expired) -> cache 240 secs 12.5% will get server B (from the 25% of a that now expired) -> cache 120 secs 6.25% will get server A (from the 12.5% of b that now expired) -> cache 240 secs 6.25% will get server B (from the 12.5% of b that now expired) -> cache 120 secs 12.5% will have server A cached -> cache another 120 secs ... i think i lost something at this point but i think you get the idea.... As you can see this gets pretty complicated to predict and it will for sure not work out like this in practice. But it should definitely have an effect on the distribution! I know that weighted round robin exists and is just controlled by the root server. It just cycles through dns records when responding and returns dns records with a set propability that corresponds to the weighting. My DNS server does not support this, and my requirements are not that precise. If it doesnt weight perfectly its okay, but it should go into the right direction. I think using the TTL field could be a more elegant and easier solution - and it deosnt require a dns server that controls this dynamically, which saves resources - which is in my opinion the whole point of dns load balancing vs hardware load balancers. My question now is... are there any best prectices / methos / rules of thumb to weight round robin distribution using the TTL attribute of DNS records? Edit: The system is a forward proxy server system. The amount of Bandwidth (not requests) exceeds what one single server with ethernet can handle. So I need a balancing solution that distributes the bandwidth to several servers. Are there any alternative methods than using DNS? Of course I can use a load balancer with fibre channel etc, but the costs are rediciulous and it also increases only the width of the bottleneck and does not eliminate it. The only thing i can think of are anycast (is it anycast or multicast?) ip addresses, but I don't have the means to set up such a system.

    Read the article

  • Windows 7 - sharing file - slow seek time?

    - by progtick
    I do not want to copy the files. I simply have video files (.flv) on one computer and I would like another computer user to watch them without copying. Playback is fine, but seek time (as in if you move the cursor to skip some portion of the video) takes forever! I thought wireless speed might be the culprit, so I wired the two computer. Maybe I saw some improvement but still so bad. It's 1 Gbps! (I know real speed will vary, but before I monitor real speed and such, do I have reasonable issue? Or am I bound to have very slow seek time?) What is going on? I must mention some of these files are huge!

    Read the article

  • Improving TCP performance over a gigabit network lots of connections and high traffic for storage and streaming services

    - by Linux Guy
    I have two servers, Both servers hardware Specification are Processor : Dual Processor RAM : over 128 G.B Hard disk : SSD Hard disk Outging Traffic bandwidth : 3 Gbps network cards speed : 10 Gbps Server A : for Encoding videos Server B : for storage videos andstream videos over web interface like youtube The inbound bandwidth between two servers is 10Gbps , the outbound bandwidth internet bandwidth is 500Mpbs Both servers using public ip addresses in public and private network Both servers transfer and connection on nginx port , and the server B used for streaming media , like youtube stream videos Both servers in same network , when i do ping from Server A to Server B i got high time latency above 1.0ms , the time range time=52.7 ms to time=215.7 ms - This is the output of iftop utility 353Mb 707Mb 1.04Gb 1.38Gb 1.73Gb mqqqqqqqqqqqqqqqqqqqqqqqqqqqvqqqqqqqqqqqqqqqqqqqqqqqqqqqvqqqqqqqqqqqqqqqqqqqqqqqqqqqvqqqqqqqqqqqqqqqqqqqqqqqqqqqvqqqqqqqqqqqqqqqqqqqqqqqqqqq server.example.com => ip.address 6.36Mb 4.31Mb 1.66Mb <= 158Kb 94.8Kb 35.1Kb server.example.com => ip.address 1.23Mb 4.28Mb 1.12Mb <= 17.1Kb 83.5Kb 21.9Kb server.example.com => ip.address 395Kb 3.89Mb 1.07Mb <= 6.09Kb 109Kb 28.6Kb server.example.com => ip.address 4.55Mb 3.83Mb 1.04Mb <= 55.6Kb 45.4Kb 13.0Kb server.example.com => ip.address 649Kb 3.38Mb 1.47Mb <= 9.00Kb 38.7Kb 16.7Kb server.example.com => ip.address 5.00Mb 3.32Mb 1.80Mb <= 65.7Kb 55.1Kb 29.4Kb server.example.com => ip.address 387Kb 3.13Mb 1.06Mb <= 18.4Kb 39.9Kb 15.0Kb server.example.com => ip.address 3.27Mb 3.11Mb 1.01Mb <= 81.2Kb 64.5Kb 20.9Kb server.example.com => ip.address 1.75Mb 3.08Mb 2.72Mb <= 16.6Kb 35.6Kb 32.5Kb server.example.com => ip.address 1.75Mb 2.90Mb 2.79Mb <= 22.4Kb 32.6Kb 35.6Kb server.example.com => ip.address 3.03Mb 2.78Mb 1.82Mb <= 26.6Kb 27.4Kb 20.2Kb server.example.com => ip.address 2.26Mb 2.66Mb 1.36Mb <= 51.7Kb 49.1Kb 24.4Kb server.example.com => ip.address 586Kb 2.50Mb 1.03Mb <= 4.17Kb 26.1Kb 10.7Kb server.example.com => ip.address 2.42Mb 2.49Mb 2.44Mb <= 31.6Kb 29.7Kb 29.9Kb server.example.com => ip.address 2.41Mb 2.46Mb 2.41Mb <= 26.4Kb 24.5Kb 23.8Kb server.example.com => ip.address 2.37Mb 2.39Mb 2.40Mb <= 28.9Kb 27.0Kb 28.5Kb server.example.com => ip.address 525Kb 2.20Mb 1.05Mb <= 7.03Kb 26.0Kb 12.8Kb qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq TX: cum: 102GB peak: 1.65Gb rates: 1.46Gb 1.44Gb 1.48Gb RX: 1.31GB 24.3Mb 19.5Mb 18.9Mb 20.0Mb TOTAL: 103GB 1.67Gb 1.48Gb 1.46Gb 1.50Gb I check the transfer speed using iperf utility From Server A to Server B # iperf -c 0.0.0.2 -p 8777 ------------------------------------------------------------ Client connecting to 0.0.0.2, TCP port 8777 TCP window size: 85.3 KByte (default) ------------------------------------------------------------ [ 3] local 0.0.0.1 port 38895 connected with 0.0.0.2 port 8777 [ ID] Interval Transfer Bandwidth [ 3] 0.0-10.8 sec 528 KBytes 399 Kbits/sec My Current Connections in Server B # netstat -an|grep ":8777"|awk '/tcp/ {print $6}'|sort -nr| uniq -c 2072 TIME_WAIT 28 SYN_RECV 1 LISTEN 189 LAST_ACK 139 FIN_WAIT2 373 FIN_WAIT1 3381 ESTABLISHED 34 CLOSING Server A Network Card Information Settings for eth0: Supported ports: [ TP ] Supported link modes: 100baseT/Full 1000baseT/Full 10000baseT/Full Supported pause frame use: No Supports auto-negotiation: Yes Advertised link modes: 10000baseT/Full Advertised pause frame use: No Advertised auto-negotiation: Yes Speed: 10000Mb/s Duplex: Full Port: Twisted Pair PHYAD: 0 Transceiver: external Auto-negotiation: on MDI-X: Unknown Supports Wake-on: d Wake-on: d Current message level: 0x00000007 (7) drv probe link Link detected: yes Server B Network Card Information Settings for eth2: Supported ports: [ FIBRE ] Supported link modes: 10000baseT/Full Supported pause frame use: No Supports auto-negotiation: No Advertised link modes: 10000baseT/Full Advertised pause frame use: No Advertised auto-negotiation: No Speed: 10000Mb/s Duplex: Full Port: Direct Attach Copper PHYAD: 0 Transceiver: external Auto-negotiation: off Supports Wake-on: d Wake-on: d Current message level: 0x00000007 (7) drv probe link Link detected: yes ifconfig server A eth0 Link encap:Ethernet HWaddr 00:25:90:ED:9E:AA inet addr:0.0.0.1 Bcast:0.0.0.255 Mask:255.255.255.0 UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:1202795665 errors:0 dropped:64334 overruns:0 frame:0 TX packets:2313161968 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:893413096188 (832.0 GiB) TX bytes:3360949570454 (3.0 TiB) lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:65536 Metric:1 RX packets:2207544 errors:0 dropped:0 overruns:0 frame:0 TX packets:2207544 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:247769175 (236.2 MiB) TX bytes:247769175 (236.2 MiB) ifconfig Server B eth2 Link encap:Ethernet HWaddr 00:25:90:82:C4:FE inet addr:0.0.0.2 Bcast:0.0.0.2 Mask:255.255.255.0 UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:39973046980 errors:0 dropped:1828387600 overruns:0 frame:0 TX packets:69618752480 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:3013976063688 (2.7 TiB) TX bytes:102250230803933 (92.9 TiB) lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:65536 Metric:1 RX packets:1049495 errors:0 dropped:0 overruns:0 frame:0 TX packets:1049495 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:129012422 (123.0 MiB) TX bytes:129012422 (123.0 MiB) Netstat -i on Server B # netstat -i Kernel Interface table Iface MTU Met RX-OK RX-ERR RX-DRP RX-OVR TX-OK TX-ERR TX-DRP TX-OVR Flg eth2 9000 0 42098629968 0 2131223717 0 73698797854 0 0 0 BMRU lo 65536 0 1077908 0 0 0 1077908 0 0 0 LRU I Turn up send/receive buffers on the network card to 2048 and problem still persist I increase the MTU for server A and problem still persist and i increase the MTU for server B for better connectivity and transfer speed but it couldn't transfer at all The problem is : as you can see from iperf utility, the transfer speed from server A to server B slow when i restart network service in server B the transfer in server A at full speed, after 2 minutes , it's getting slow How could i troubleshoot slow speed issue and fix it in server B ? Notice : if there any other commands i should execute in servers for more information, so it might help resolve the problem , let me know in comments

    Read the article

  • ata error: UnrecovData Handshk

    - by Aaron Digulla
    I just saw this message in my log (openSUSE 11.3, Linux 2.6.36.2): ata6.00: exception Emask 0x10 SAct 0x1 SErr 0x400100 action 0x6 frozen ata6.00: irq_stat 0x08000000, interface fatal error ata6: SError: { UnrecovData Handshk } ata6.00: failed command: WRITE FPDMA QUEUED ata6.00: cmd 61/58:00:9f:69:00/00:00:00:00:00/40 tag 0 ncq 45056 out res 40/00:04:9f:69:00/00:00:00:00:00/40 Emask 0x10 (ATA bus error) ata6.00: status: { DRDY } ata6: hard resetting link ata6: SATA link up 3.0 Gbps (SStatus 123 SControl 300) ata6.00: configured for UDMA/133 ata6: EH complete Two questions: Which disk caused the error? I search /sys and /proc but couldn't find a way to map ata6 to a device (/dev/sdaXY) When such an error happens, does Linux retry the disk operation? Or do I have a corrupt filesystem?

    Read the article

  • Can I increase the link speed of the RAS Server on our MS Win2k3 box?

    - by Ducain
    We are running a Win2K3 Server box, and I'm a remote employee that connects via VPN. I've been frustrated for some time by the connection speed over the VPN (the office HQ has a decent speed and I have a biz class connection here), and decided to do some checking today. This morning, I was dialed in and looked at the networking tab of the task manager, and I see that the adapter for the RAS Server (the box has 4 Gigabit adapters) has a speed that seems far too low. The speed for the RAS Server link hovers between 300 - 600 Kbps. The local connection (and others) all say 1 Gbps. Can I set this to a higher speed? Is this information accurate? Thanks for the input.

    Read the article

  • University Assignment: Datacenter/Networking Infrastructure for Hosting Company [closed]

    - by TCB13
    My university assigned me to theorizing a data center for an Web Hosting company. The company should provide the following services: Shared WebHosting; Dedicated Servers; VPS (Virtual Private Server); The bandwith (as resquested) is limited to 10 Gbps. Is there any good book / other info I can read (max 100 pages) about how to design a good data center for hosting, what are the best practices and what should be done from a (logical) network perspective, what security policies should be implemented and how the data center should be built (physically)? Thank you ;)

    Read the article

  • Suggestions on providing HA access to an external (fibre) RAID subsystem

    - by user145198
    We are looking at upgrading our storage capacity with an external RAID subsystem that has redundant (2) fibre controllers, each controller has 4 x 8 Gbps fibre ports. I would like to make access to this storage system occur via HA Linux. Ideally I would connect 2 fibre ports from each controller into each Linux server, and then export either NFS or iSCSI via a 10 Gbe interface. I have seen plenty of references to DRBD, however all of those references tend to use block storage that is solely attached to each machine, rather than having a shared block storage device, so I am unsure if DRBD could (or should) be used in this case. Ideas?

    Read the article

  • Does Apache 2.2 (windows) have any default bandwidth limit?

    - by igino manfre'
    I'm running Apache on a server in cloud (Windows server 2008 R2 on VMware, 1 Gbps of BW, http://95.110.164.61 ). I'm streaming many live DVB MPEG Transport Stream, precompressed in loop, (not flash) generated by VLC on port 640xx and then reverse proxied by Apache on port 80. The server's firewall is open for VLC and Apache on all ports. Above 1.5 Mbps the reproduction is affected by continous stop & go. Please note that if you request a stream generated by VLC directly at http://95.110.164.61:64087/mpg2_6.4 you see a correct stream, while if you request http://95.110.164.61/mpg2_6.4 you do not. I know that Flash streaming Server uses Apache to stream on port 80 (and it works). I'm not an expert with Apache, can anyone tell me if any "special" module is required to increase the bandwidth?

    Read the article

  • Gigabit connection between 2 computers

    - by Alecu
    I am trying to set up a connection between 2 pc's. It's a direct cable connection. The problem that I am having is that the connection isn't gigabit. I know both network cards support gigabit. I checked in the device settings and in one pc I can see in the Speed & Duplex the 1Gbps option but on the other pc I can't see that option despite the fact that the network card is gigabit. I have quite some files to copy from one pc onto another and I really need a good connection between them. I can't really remove the hard drive because it would void the warranty. Could this be a driver issue or a cable issue? On both pc's I have windows 8. The network card on the pc that doesn't have the 1 gbps option is an Atheros ar8161 card.

    Read the article

  • Hardware settings reviewing

    - by dino99
    Get some hardware related errors logged into dmesg: oem@dub:~$ dmesg | grep ata10 [ 1.007989] ata10: PATA max UDMA/133 cmd 0xa800 ctl 0xa480 bmdma 0xa408 irq 18 [ 1.691664] ata10: prereset failed (errno=-19) [ 1.691670] ata10: reset failed, giving up oem@dub:~$ dmesg | grep ata2 [ 0.990290] ata2: SATA max UDMA/133 abar m1024@0xfebfb800 port 0xfebfb980 irq 45 [ 1.688011] ata2: SATA link up 3.0 Gbps (SStatus 123 SControl 300) [ 1.688055] ata2.00: unsupported device, disabling [ 1.688057] ata2.00: disabled As I understand, its related to my old Seagate SATA HDD, and the PATA CDROM. These errors are quite new, so I feel that their settings (dma, write-cache, ...) have been modified by some upgrades. I've already used hdparm to set write-cache off on the HDDs. But it seems like I need to review some other setting(s) too. With oldest distro it was easy to know about the hardware settings, but now on Quantal/Precise its deeply hidden for the average user. So i would like to know how to view/modify these settings. About the CDROM reader, the problem is different: - the system don't identify it with an UUID; but only with ATAPI or by-id oem@dub:~$ dmesg|grep 'ATAPI' [ 1.308611] ata3.00: ATAPI: TSSTcorp CDDVDW SH-S203D, SB00, max UDMA/100 oem@dub:~$ ls -l /dev/disk/by-id/ ...... lrwxrwxrwx 1 root root 9 oct. 1 06:42 ata-TSSTcorp_CDDVDW_SH-S203D -> ../../sr0 .....

    Read the article

  • How do I target a specific driver for libata kernel parameter modding?

    - by DanielSmedegaardBuus
    Sorry for the cryptic title. Not sure how to phrase it. This is it in a nutshell: I'm running a 22-disk setup, 19 of those in a ZFS array, 15 of those backed by three port multipliers attached to SATA controllers driven by the sata_sil24 module. When running full speed (SATA2, i.e. 3 Gbps), the operation is pretty quirky (simple read errors will throw an entire PMP into spasms for a long time, sometimes with pretty awful results). Booting with kernel parameter libata.force=1.5G to force SATA controllers into "legacy" speeds completely fixes all issues with the PMPs. Thing is, my ZFS pool is backed by a fast cache SSD on my ICH10R controller. Another SSD on this same controller holds the system. Doing libata.force=1.5G immediately shaves about 100 MB/s off the transfer rate of my SSDs. For the root drive, that's not such a big deal, but for the ZFS cache SSD, it is. It effectively makes the entire zpool slower for sustained transfers than it would've been without the cache drive. Random access and fs tree lookups, of course still benifit. I'm hoping, though, that there's some way to pass the .force=1.5G parameter on to just the three SATA controllers being backed by the sata_sil24 module. But listing the module options for this, no such option exists. Is this possible? And if so, how? Thanks :)

    Read the article

  • Apache DVB http video Streaming bandwidth or priority problem

    - by igino manfre'
    I'm streaming few precompressed DVB videos from cloud. The streams are generated from VLC on "impossible" ports (such as 64085, 64086 etc) reverse proxed by Apache on port 80 and 8080. All the generated streams are listed in "http://95.110.164.61/indexv.html". From an ADSL connection with enough downlink bandwidth, recalling the stream generated by VLC (such as "http://95.110.164.61:64087/mpg2_6.4") it flows fluently. Recalling the same stream proxed by Apache ("http://95.110.164.61/mpg2_6.4") the stream stops and goes. The only situation in which the Apache proxed streams flow regularly is from a site connected through 64 Mbps warranted bandwith with RTT to the server less than 10 mseconds. Please note that streams below 2 Mbps are fluently proxed. The system is a single core xeon with windows 2008 R2 on 4 GB of RAM with 1 Gbps of network bandwidth. The drain of computational and bandwidth resources is negligeable, the RAM usage always lower than 50%. On the system I run many VLC streamers. Any of them drains a variable amount of RAM (from about 25 to 70 MB). On the contrary the couple of httpd.exe processes drain no more than 7 MB. Using Wireshark (on the server) I see that VLC directy send to the client much more packets than Apache, and the stream is framgmented on many frames. I'm not a programmer, a newby of Apache. Can anyone please address me to a specific portion of the Apache's huge documentation? Thank you. igino

    Read the article

  • Apache Prefork Configuration

    - by user1618606
    I'm newbie on VPS configuration. So, I've installed apache, php and mysql and now I need to know how to configure Prefork to optimize Apache. The system configuration is: CPU Cores 2 x 2 Ghz @ 4 Ghz RAM Memory 2304 MB DDR3 Burst Memory 3 GB DDR3 Disk Space 30 GB SSD Bandwidth 3 TB SwitchPort 1 Gbps Actually, after linux, mysql, apache and php, there are 250 MB memory in use. Well, I don't have idea to calculate. I saw in some websistes, some vars like: KeepAlive On KeepAliveTimeout 1 MaxKeepAliveRequests 100 StartServers 15 MinSpareServers 15 MaxSpareServers 15 MaxClients 20 MaxRequestsPerChild 0 or StartServers 2 MaxClients 150 MinSpareThreads 25 MaxSpareThreads 75 ThreadsPerChild 25 MaxRequestsPerChild 0 How I could to do: Prefork or worker? Where and how the vars are placed? In httpd.conf? Big hug, Claudio.

    Read the article

  • Virtualized data centre&ndash;Part four: The design

    - by marc dekeyser
    Welcome back to the fourth post in this series! Today we will have a look at what Microsoft recommends as a “private cloud design” and what I will make of it. Whilst my own solution is based of the reference architecture, it is quite different indeed! An important thing to know is that, whilst I am using the private cloud as a reference, I am skipping most of the steps in designing a private cloud. If that is why you are here, please read the links at the end of the article and skim through my own content. A private cloud is much more process driven than just building a virtual infrastructure… The architecture of it all… So imagine for a minute that you have unlimited funds to build this lab of yours… You’d want redundancy on all levels and separation of each network where possible! Unfortunately we don’t have that luxury and, as you saw me hinting at in the previous article, our own design will be more limited but still quite capable! Networking From the networking perspective I will not have a fully redundant network, after all, this is but a lab environment! Thanks to Server 2012 I will be able to use bonding on my NIC’s and use LACP to improve the performance on that part. Storage As I mentioned in the previous article a Synology DS1218+ will be used for iSCSI provisioning. This device has 2 NICs on-board which can be bonded in to one 2 Gbps interface giving me a decent throughput and making the disks the most limiting factor in the storage design. Domain controllers and extra infrastructure Server 2012 completely supports running domain controllers virtualized and has no need to actually have a reachable DC when booting… That being said I need a remote access machine to power on the hosts (I have no need for them running 24/7) and a possible System Center VMM 2012 box (although server 2012 is not supported until SP1 :( ). Undecided on if I am to install those boxes separately or as a virtual machine… Which amounts to… Something like this pretty picture!                   Sources Microsoft Private Cloud Solutions Repository (en-US) http://social.technet.microsoft.com/wiki/contents/articles/12131.microsoft-private-cloud-solutions-repository-en-us.aspx Reference  Architecture: http://social.technet.microsoft.com/wiki/contents/articles/3819.reference-architecture-for-private-cloud.aspx Private Cloud Reference Model: http://social.technet.microsoft.com/wiki/contents/articles/4399.private-cloud-reference-model.aspx

    Read the article

  • Setup of HP ProCurve 2810-24G for iSCSI?

    - by 3molo
    Hi, I have a pair of ProCurve 2810-24G that I will use with a Dell Equallogic SAN and Vmware ESXi. Since ESXi does MPIO, I am a little uncertain on the configuration for links between the switches. Is a trunk the right way to go between the switches? I know that the ports for the SAN and the ESXi hosts should be untagged, so does that mean that I want tagged VLAN on the trunk ports? This is more or less the configuration: trunk 1-4 Trk1 Trunk snmp-server community "public" Unrestricted vlan 1 name "DEFAULT_VLAN" untagged 24,Trk1 ip address 10.180.3.1 255.255.255.0 no untagged 5-23 exit vlan 801 name "Storage" untagged 5-23 tagged Trk1 jumbo exit no fault-finder broadcast-storm stack commander "sanstack" spanning-tree spanning-tree Trk1 priority 4 spanning-tree force-version RSTP-operation The Equallogic PS4000 SAN has two controllers, with two network interfaces each. Dell recommends each controller to be connected to each of the switches. From vmware documentation, it seems creating one vmkernel per pNIC is recommended. With MPIO, this could allow for more than 1 Gbps throughput.

    Read the article

  • Ubuntu raid 1 write errors

    - by Micah
    I have an Ubuntu server set up with two SATA drives in a RAID 1 configuration with MDADM. The machine is used to record raw video, which involves a lot of writing to the disk. Sometimes during video recording the computer will crash, will the following errors in kern.log: Mar 15 10:39:41 video kernel: [414501.629864] ata2.00: exception Emask 0x10 SAct 0x0 SErr 0x400100 action 0x6 Mar 15 10:39:41 video kernel: [414501.629870] ata2.00: BMDMA stat 0x26 Mar 15 10:39:41 video kernel: [414501.629875] ata2.00: SError: { UnrecovData Handshk } Mar 15 10:39:41 video kernel: [414501.629880] ata2.00: failed command: WRITE DMA EXT Mar 15 10:39:41 video kernel: [414501.629889] ata2.00: cmd 35/00:00:28:6d:f6/00:04:06:00:00/e0 tag 0 dma 524288 out Mar 15 10:39:41 video kernel: [414501.629891] res 51/84:b1:77:6e:f6/84:02:06:00:00/e0 Emask 0x30 (host bus error) Mar 15 10:39:41 video kernel: [414501.629896] ata2.00: status: { DRDY ERR } Mar 15 10:39:41 video kernel: [414501.629899] ata2.00: error: { ICRC ABRT } Mar 15 10:39:41 video kernel: [414501.629910] ata2.00: hard resetting link Mar 15 10:39:41 video kernel: [414501.973009] ata2.01: hard resetting link Mar 15 10:39:41 video kernel: [414502.482642] ata2.00: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Mar 15 10:39:41 video kernel: [414502.482658] ata2.01: SATA link down (SStatus 0 SControl 300) Mar 15 10:39:41 video kernel: [414502.546160] ata2.00: configured for UDMA/133 Mar 15 10:39:41 video kernel: [414502.546203] ata2: EH complete Is this the result of faulty drives? Is software RAID just not performant enough for data rates ~15 MB/s, even with a quad-core i7? Thanks for your help. Edit: cat /proc/mdstat returns this: Personalities : [linear] [multipath] [raid0] [raid1] [raid6] [raid5] [raid4] [raid10] md0 : active raid1 sdb1[1] sda1[0] 976760768 blocks [2/2] [UU] unused devices: <none>

    Read the article

  • Poor Write Performance in VM inside Proxmox PVE 2.0

    - by sorsenne
    I am running a PVE 2.0 on a decent Hardware (2 SATA HDDs as RAID1, 12GB RAM, i7 CPU) but the I/O Performance is very poor inside the VM (Ubuntu 11.10 Server). The very same VM was copied to another Server running simply Ubuntu Server with KVM and had better I/O Perf. this is how the HDD is shown in the Guest: ata1: SATA link up 6.0 Gbps (SStatus 133 SControl 300) ata1.00: ATA-8: ST3000DM001-9YN166, CC49, max UDMA/133 ata1.00: 5860533168 sectors, multi 16: LBA48 NCQ (depth 31/32), AA ata1.00: configured for UDMA/133 scsi 0:0:0:0: Direct-Access ATA ST3000DM001-9YN1 CC49 PQ: 0 ANSI: 5 sd 0:0:0:0: [sda] 5860533168 512-byte logical blocks: (3.00 TB/2.72 TiB) sd 0:0:0:0: [sda] 4096-byte physical blocks sd 0:0:0:0: [sda] Write Protect is off sd 0:0:0:0: [sda] Mode Sense: 00 3a 00 00 sd 0:0:0:0: [sda] Write cache: enabled, read cache: enabled, doesn't support DPO or FUA I tested with DD: $ dd bs=1M count=128 if=/dev/zero of=test conv=fdatasync 128+0 records in 128+0 records out 134217728 bytes (134 MB) copied, 19.2222 s, 7.0 MB/s on the Host, this same Test will result with 156 MB/s in average. PS: I am using VirtIO and see no error in dmesg.

    Read the article

  • 100% iowait + drive faults in dmesg

    - by w00t
    Hi, I have a server on which resides a fairly visited web app. It has a raid1 of 2 HDDs, 64MB Buffer, 7200 RPM. Today it started throwing out errors like: kernel: ata2.00: exception Emask 0x0 SAct 0x0 SErr 0x0 action 0x6 frozen kernel: ata2.00: cmd b0/d0:01:00:4f:c2/00:00:00:00:00/00 tag 0 pio 512 in kernel: res 40/00:00:00:4f:c2/00:00:00:00:00/00 Emask 0x4 (timeout) kernel: ata2.00: status: { DRDY } kernel: ata2: hard resetting link kernel: ata2: SATA link up 3.0 Gbps (SStatus 123 SControl 300) kernel: ata2.00: max_sectors limited to 256 for NCQ kernel: ata2.00: max_sectors limited to 256 for NCQ kernel: ata2.00: configured for UDMA/133 kernel: sd 1:0:0:0: timing out command, waited 7s kernel: ata2: EH complete kernel: SCSI device sda: 976773168 512-byte hdwr sectors (500108 MB) kernel: sda: Write Protect is off kernel: SCSI device sda: drive cache: write back All day long it has been in load higher than 10-15. I am monitoring it with atop and it gives some bizarre readings: DSK | sda | busy 100% | read 2 | write 208 | KiB/r 16 | KiB/w 32 | MBr/s 0.00 | MBw/s 0.65 | avq 86.17 | avio 47.6 ms | DSK | sdb | busy 1% | read 10 | write 117 | KiB/r 17 | KiB/w 5 | MBr/s 0.02 | MBw/s 0.07 | avq 4.86 | avio 1.04 ms | I frankly don't understand why only sda is taking all the hit. I do have one process that is constantly writing with 1-2megs but what the hell.. 100% iowait?

    Read the article

  • No internet access when using static IP

    - by Endy Tjahjono
    I have just upgraded to Windows 8.1, and after the upgrade process is finished, I can't connect to internet. I tried running the "Troubleshoot problems": It concluded that DHCP needs to be activated: I let it activate DHCP, and I got internet connection back. The problem is I want to set this PC to a certain IP address (the IP address that it has been using all this time). I am also using Hyper-V, which I suspect has something to do with this problem. After I regained internet connection, I tried running one of my Hyper-V VM. From inside the VM I can connect to internet. That VM has static IP address. I also noticed that in "Control Panel\Network and Internet\Network Connections", I usually have a network connection called vEthernet (Realtek PCIe GBE Family Controller Virtual Switch). I didn't find it there after upgrade. How do I set my PC to a static IP while retaining internet access in Windows 8.1? EDIT I have managed to recreate vEthernet (Realtek PCIe GBE Family Controller Virtual Switch) by unchecking Allow management operating system to share this network adapter in Hyper-V's Virtual Switch Manager and then checking it again. But when I changed the adapter to use static IP, it still can't connect to internet. Result of Get-NetAdapter -Name * | fl (with MAC address removed): Name : vEthernet (Realtek PCIe GBE Family Controller Virtual Switch) InterfaceDescription : Hyper-V Virtual Ethernet Adapter #2 InterfaceIndex : 5 MacAddress : 55-55-55-55-55-55 MediaType : 802.3 PhysicalMediaType : Unspecified InterfaceOperationalStatus : Up AdminStatus : Up LinkSpeed(Mbps) : 100 MediaConnectionState : Connected ConnectorPresent : False DriverInformation : Driver Date 2006-06-21 Version 6.3.9600.16384 NDIS 6.40 Name : Ethernet 3 InterfaceDescription : Hyper-V Virtual Ethernet Adapter #3 InterfaceIndex : 6 MacAddress : 55-55-55-55-55-56 MediaType : 802.3 PhysicalMediaType : Unspecified InterfaceOperationalStatus : Up AdminStatus : Up LinkSpeed(Gbps) : 10 MediaConnectionState : Connected ConnectorPresent : False DriverInformation : Driver Date 2006-06-21 Version 6.3.9600.16384 NDIS 6.40 Name : Ethernet InterfaceDescription : Realtek PCIe GBE Family Controller InterfaceIndex : 2 MacAddress : 55-55-55-55-55-57 MediaType : 802.3 PhysicalMediaType : 802.3 InterfaceOperationalStatus : Up AdminStatus : Up LinkSpeed(Mbps) : 100 MediaConnectionState : Connected ConnectorPresent : True DriverInformation : Driver Date 2013-05-10 Version 8.1.510.2013 NDIS 6.30

    Read the article

  • Is this hard disk dead?

    - by Korjavin Ivan
    Not sure, is this right site for this Q, but let me try Last time i have problem with hard disk. Sometimes its do strange sound, and i get it from logs: $dmesg | grep ata4 [29409.945516] ata4.00: exception Emask 0x10 SAct 0xf SErr 0x90202 action 0xe frozen [29409.945529] ata4.00: irq_stat 0x00400000, PHY RDY changed [29409.945538] ata4: SError: { RecovComm Persist PHYRdyChg 10B8B } [29409.945546] ata4.00: failed command: READ FPDMA QUEUED [29409.945562] ata4.00: cmd 60/30:00:56:22:5f/00:00:00:00:00/40 tag 0 ncq 24576 in [29409.945573] ata4.00: status: { DRDY } [29409.945580] ata4.00: failed command: READ FPDMA QUEUED [29409.945594] ata4.00: cmd 60/18:08:8e:22:5f/00:00:00:00:00/40 tag 1 ncq 12288 in [29409.945605] ata4.00: status: { DRDY } [29409.945611] ata4.00: failed command: READ FPDMA QUEUED [29409.945625] ata4.00: cmd 60/08:10:46:02:66/00:00:00:00:00/40 tag 2 ncq 4096 in [29409.945635] ata4.00: status: { DRDY } [29409.945641] ata4.00: failed command: READ FPDMA QUEUED [29409.945656] ata4.00: cmd 60/80:18:ee:04:66/00:00:00:00:00/40 tag 3 ncq 65536 in [29409.945666] ata4.00: status: { DRDY } [29409.945679] ata4: hard resetting link [29413.976083] ata4: softreset failed (device not ready) [29413.976097] ata4: applying SB600 PMP SRST workaround and retrying [29414.148070] ata4: SATA link up 3.0 Gbps (SStatus 123 SControl 300) [29414.184986] ata4.00: SB600 AHCI: limiting to 255 sectors per cmd [29414.243280] ata4.00: SB600 AHCI: limiting to 255 sectors per cmd [29414.243292] ata4.00: configured for UDMA/133 [29414.243324] ata4: EH complete [680674.804563] ata4: exception Emask 0x50 SAct 0x0 SErr 0x90a02 action 0xe frozen [680674.804575] ata4: irq_stat 0x00400000, PHY RDY changed [680674.804584] ata4: SError: { RecovComm Persist HostInt PHYRdyChg 10B8B } [680674.804603] ata4: hard resetting link [680678.840561] ata4: softreset failed (device not ready) Is this ata4 sata hard drive dead? Must i change it ASAP ? Need I specify more info?

    Read the article

  • Ubuntu hard disk getting SATA errors

    - by Henadzy
    I am getting "UNC" errors on a hard disk on Ubuntu 9.10. It slows down my system, applications have not been responding for a long time. But when I mount the filesystem on another computer, it works properly. disk: SAMSUNG HD161HJ (SATA) syslog: Apr 25 00:28:25 vare6gin kernel: [ 885.773839] ata3.00: exception Emask 0x1 SAct 0x1e SErr 0x0 action 0x6 frozen Apr 25 00:28:25 vare6gin kernel: [ 885.773845] ata3.00: Ata error. fis:0x21 Apr 25 00:28:25 vare6gin kernel: [ 885.773861] ata3.00: cmd 60/08:08:3f:00:ad/00:00:10:00:00/40 tag 1 ncq 4096 in Apr 25 00:28:25 vare6gin kernel: [ 885.773864] res 51/40:24:67:c8:91/40:00:05:00:00/40 Emask 0x9 (media error) Apr 25 00:28:25 vare6gin kernel: [ 885.773871] ata3.00: status: { DRDY ERR } Apr 25 00:28:25 vare6gin kernel: [ 885.773877] ata3.00: error: { UNC } [...snip 3 similar repeats of last 4 lines; see revision history for full log...] Apr 25 00:28:25 vare6gin kernel: [ 885.773970] ata3: hard resetting link Apr 25 00:28:25 vare6gin kernel: [ 885.773974] ata3: nv: skipping hardreset on occupied port Apr 25 00:28:25 vare6gin kernel: [ 886.240073] ata3: SATA link up 3.0 Gbps (SStatus 123 SControl 300) Apr 25 00:28:25 vare6gin kernel: [ 886.256277] ata3.00: configured for UDMA/133 Apr 25 00:28:25 vare6gin kernel: [ 886.256305] ata3: EH complete Apr 25 00:28:27 vare6gin kernel: [ 888.176088] ata3: EH in SWNCQ mode,QC:qc_active 0xF sactive 0xF Apr 25 00:28:27 vare6gin kernel: [ 888.176099] ata3: SWNCQ:qc_active 0xF defer_bits 0x0 last_issue_tag 0x3 Apr 25 00:28:27 vare6gin kernel: [ 888.176102] dhfis 0xF dmafis 0x1 sdbfis 0x0 Apr 25 00:28:27 vare6gin kernel: [ 888.176109] ata3: ATA_REG 0x51 ERR_REG 0x40 Apr 25 00:28:27 vare6gin kernel: [ 888.176113] ata3: tag : dhfis dmafis sdbfis sacitve Apr 25 00:28:27 vare6gin kernel: [ 888.176120] ata3: tag 0x0: 1 1 0 1 Apr 25 00:28:27 vare6gin kernel: [ 888.176126] ata3: tag 0x1: 1 0 0 1 Apr 25 00:28:27 vare6gin kernel: [ 888.176131] ata3: tag 0x2: 1 0 0 1 Apr 25 00:28:27 vare6gin kernel: [ 888.176136] ata3: tag 0x3: 1 0 0 1

    Read the article

  • Gigabit LAN not working on ASUS M2N-MX

    - by chmod
    Today I replace my FastEthernet switch with a newly bought gigabit switch (DGS-1008A). All computers in my house are displaying that the connection speed is 1 Gbps except for one. The computer that is not working is an ASUS M2N-MX which contain an onboard gigabit NIC. See ASUS link for confirmation http://www.asus.com/Motherboards/AMD_AM2/M2NMX/ Here are some info of the machine OS: Windows 7 Ultimate SP1 64bit BIOS version: 1004 (latest) Driver: installed via Windows update (latest from Windows update) Windows Update: fully updated The machine is reformatted 3 days ago, so it's pretty clean, no junk, no virus, etc Cable: Amp CAT5E 5 meters In device manager, the name of the NIC is "NVIDIA nForce 10/100/1000 Mbps Ethernet" What I have try: I did try to install the driver provided in ASUS website, but there isn't any for Windows 7 64 or Vista 64. I did try to install the latest nForce340/6100, downloaded from Nvidia website. However, the LAN driver refuse to install, it complain that I already have the best driver installed. I looking in the property -- advance tab -- Speed/duplex settings, in an attempt to force it to run at 1000Mbps, but there is no 1000Mbps choice, only 10 and 100Mpbs. I change the CAT5E cable (use one from another computer that is running gigabit without problem) Anyone have this issue or know how to solve it? Thanks

    Read the article

  • xen + debian network after upgrade squeeze to wheeze

    - by rush
    I've got a Debian + Xen server. After a system upgrade to the stable version the network doesn't come up after boot. Every time after reboot I need to bring it up manually. The network configuration was not changed during upgrade. Here is /etc/network/interfaces: auto lo iface lo inet loopback auto eth0 iface eth0 inet static address 11.22.33.44 netmask 255.255.255.0 gateway 11.22.33.1 nameserver 8.8.8.8 After boot ip r shows no route and eth0 has no ip address. Manually ip and route setup goes fine and network starts working. Messages from dmesg about network I've found (looks like nothing interesting) [ 3.894401] ACPI: Fan [FAN3] (off) [ 3.894444] ACPI: Fan [FAN4] (off) [ 4.178348] e1000e 0000:00:19.0: eth0: (PCI Express:2.5GT/s:Width x1) 00:1e:67:14:66:c9 [ 4.178351] e1000e 0000:00:19.0: eth0: Intel(R) PRO/1000 Network Connection [ 4.178392] e1000e 0000:00:19.0: eth0: MAC: 10, PHY: 11, PBA No: 0100FF-0FF [ 4.178413] e1000e 0000:02:00.0: Disabling ASPM L0s L1 [ 4.178432] xen: registering gsi 16 triggering 0 polarity 1 -- [ 4.223667] ata5: DUMMY [ 4.223668] ata6: DUMMY [ 4.289153] e1000e 0000:02:00.0: eth1: (PCI Express:2.5GT/s:Width x1) 00:1e:67:14:66:c8 [ 4.289155] e1000e 0000:02:00.0: eth1: Intel(R) PRO/1000 Network Connection [ 4.289245] e1000e 0000:02:00.0: eth1: MAC: 3, PHY: 8, PBA No: 1000FF-0FF [ 4.506908] usb 1-1: new high-speed USB device number 2 using ehci_hcd [ 4.542920] ata2: SATA link up 3.0 Gbps (SStatus 123 SControl 300) -- [ 10.362999] EXT4-fs (dm-23): mounted filesystem with ordered data mode. Opts: (null) [ 10.419103] EXT4-fs (dm-3): mounted filesystem with ordered data mode. Opts: (null) [ 10.988255] ADDRCONF(NETDEV_UP): eth1: link is not ready [ 13.175533] Event-channel device installed. [ 13.287555] XENBUS: Unable to read cpu state -- [ 13.288670] XENBUS: Unable to read cpu state [ 13.965939] Bridge firewalling registered [ 14.134048] e1000e: eth1 NIC Link is Up 1000 Mbps Full Duplex, Flow Control: Rx/Tx [ 14.283862] ADDRCONF(NETDEV_UP): peth0: link is not ready [ 14.284543] ADDRCONF(NETDEV_CHANGE): eth1: link becomes ready [ 17.800627] e1000e: peth0 NIC Link is Up 1000 Mbps Full Duplex, Flow Control: Rx/Tx [ 17.801377] ADDRCONF(NETDEV_CHANGE): peth0: link becomes ready [ 18.307278] device peth0 entered promiscuous mode [ 24.538899] eth1: no IPv6 routers present [ 28.570902] peth0: no IPv6 routers present I've upgraded two servers and I've such behaviour on two of them. How to fix this and get network starts automatically on boot?

    Read the article

< Previous Page | 1 2 3 4  | Next Page >