Search Results

Search found 11826 results on 474 pages for 'parallel port'.

Page 314/474 | < Previous Page | 310 311 312 313 314 315 316 317 318 319 320 321  | Next Page >

  • A design for watching IPTV anywhere in the house?

    - by Carlos
    I'm currently getting TV and internet via IP to my house. The service comes into an ISP-supplied Router (ST585) which is in turn connected to an IPTV box. I need to replace the router, as it's port forwarding seems to be broken, so I was thinking of getting a box with an IGMP proxy. I once mistakenly got a non-IGMP box, with the result that the internet worked, but the IPTV didn't. The trouble is, I have no idea how to set up the IPTV part of the installation. I do have a copy of the ST585 configuration, but it doesn't look anything like the Cisco stuff that I learned about at CCNA. What are the steps necessary to reproduce the IGMP setup? I was thinking of WireSharking the communications on the network, but I suppose I'd need a hub for that? As a bonus, since the packets are coming in with the TV signal, is it possible to mess with the IGMP setup so I can watch TV anywhere in the house?

    Read the article

  • A design for watching IPTV anywhere in the house?

    - by Carlos
    I'm currently getting TV and internet via IP to my house. The service comes into an ISP-supplied Router (ST585) which is in turn connected to an IPTV box. I need to replace the router, as it's port forwarding seems to be broken, so I was thinking of getting a box with an IGMP proxy. I once mistakenly got a non-IGMP box, with the result that the internet worked, but the IPTV didn't. The trouble is, I have no idea how to set up the IPTV part of the installation. I do have a copy of the ST585 configuration, but it doesn't look anything like the Cisco stuff that I learned about at CCNA. What are the steps necessary to reproduce the IGMP setup? I was thinking of WireSharking the communications on the network, but I suppose I'd need a hub for that? As a bonus, since the packets are coming in with the TV signal, is it possible to mess with the IGMP setup so I can watch TV anywhere in the house?

    Read the article

  • Windows 8 - Synaptics driver - Mouse keeps freezing

    - by KickAss
    I have Win-8 Pro installed on my Dell XPS. This has Synaptic PS/2 Port TouchPad. As I upgraded the Laptop from Win7 to Win8 all my factory Mouse software (along with other preinstalled software) was all deleted. So for the mouse, I installed Windows 8/7/XP/Vista 64/32-bit Edition v16.3.15.1. Problem - every few seconds (or minutes at times), the mouse freezes. Windows is still working, it's just the mouse. I have to wait 5-15 seconds before the mouse works again. I thought this was because the Synaptic Driver I am installing is not Win-8 compatible but this is not the case. It seems the mouse freezes when Windows is working, loading or opening new programs/windows. I have the same problem in my other Laptop which has upgraded Win8 pro. This is a Dell Studio. What's causing this?

    Read the article

  • Setting up 2 external monitors on a laptop with VGA splitter

    - by mike
    I have a laptop with a graphics card that supports 2 displays. I would like to know the easiest way to set it up so I can close my laptop lid and use 2 external monitors (unique displays). I use it primarily for office applications and video and want a quality, clear picture. The laptop has 1 VGA port and I have 2 24" 1920x1200 monitors that have VGA and DVI ports. So a few questions: Can I just use a VGA splitter? (seen mixed feedback on this) Would it a VGA to 2 DVI splitter give a better picture quality? (if it exists) Would I be better upgrading laptop to one with 2 digital ports ( I just see a lot with VGA and HDMI though) specs: Model: Toshiba Satellite C675-S106 (Windows 7) Graphics Card: Intel HD Graphics 3000 (supports 2 displays) Processor: Intel Core i3-2350M

    Read the article

  • How come transparency in textures appears as white in 3ds Max?

    - by rFactor
    I have downloaded a free tree palm model that came with textures and a preview image. In the preview image the tree looks fine, but when I have deployed the textures to my scene, the leaves look green plus white, where white is the transparency area. Is there something I need to know about transparent textures? Both in the view-port and in the renderer all transparency appears as white. What could it be? Edit: The model I was talking about is implemented with two JPGs. One is textured and the other one is black-white where white represents transparency and is applied to the material in the opacity channel/map. The transparency seems to work somewhat, but there are white borders around the leaves. I think it's because the opacity channel does not properly filter out all white colors for some reason. It also seems that changing the blur affects it, but setting it to 0 does not remove it though (and makes it jaggy).

    Read the article

  • can not connect via SSH to a remote Postgresql database

    - by tartox
    I am trying to connect via pgAdmin3 GUI to a Postgresql database on a remote server myHost on port 5432. Server side : I have a Unix myUser that match a postgresql role. pg_hba.conf is : local all all trust host all all 127.0.0.1/32 trust Client side : I open an ssh tunnel : ssh -L 3333:myHost:5432 myUser@myHost I connect to the server via pgAdmin3 ( or via psql -h localhost -p 3333 ). I get the following error message : server closed the connection unexpectedly This probably means the server terminated abnormally before or while processing the request. I have tried to access a specific database with the superuser role using psql -h localhost -p 3333 --dbname=myDB --user=mySuperUser with no more success. What did I forget in the setup ? Thank you

    Read the article

  • One NIC going to sleep on Centos system

    - by sbleon
    I have two Dell boxes with two ethernet ports a piece. I have a cable directly connecting two of these ports, creating a tiny LAN with 10.3.3.x addresses. The other port on each box is hooked up to a switch and has a DHCP-supplied address to talk to the outside world. I've noticed that when scp'ing large files from one box to the other over the private LAN, the transfers sometimes stall. It appears that any other network activity on either box will cause the transfer to resume. Wake-on-LAN is disabled on all interfaces according to ethtool. What else could be causing these stalled transfers?

    Read the article

  • Finding a private (NAT) host's IP using historic destination data

    - by l0c0b0x
    The issue: An unknown private (NAT) client is infected with malware and it's trying to access a Bot server at random times/dates. How we know about this: We receive bot traffic notices/alerts from REN-ISAC. Unfortunately, we don't receive those until the next day after it has happened. What they provide to us is: The source address (of the firewall) The destination addresses (it varies, but they're going to network subnet allocated to a German ISP) The source port (which varies--dynamic ports). Question: What would be the best approach to finding this internal host (historically) with a Cisco ASA as firewall? I'm guessing blocking anything to the destination address(es), and logging that type of traffic/access might allow me to find the source host, but I'm not sure which tool/command would be the most useful. I've seen Netflow thrown into a few responses when it comes to logging, but I'm confused with it's association of Logging, NAL, and nBAR, and how they relate to Netflow.

    Read the article

  • ldirectord ipvsadm not show reals ip and not work wtih pacemaker and corosync

    - by miguer27
    first thanks for your time. I'm having a problem with ldirectord that I can not solve, I comment my situation: I have two nodes with pace maker and corosync and configure somes resources: root@ldap1:/home/mamartin# crm status Last updated: Tue Jun 3 12:58:30 2014 Last change: Tue Jun 3 12:23:47 2014 via cibadmin on ldap1 Stack: openais Current DC: ldap2 - partition with quorum Version: 1.1.7-ee0730e13d124c3d58f00016c3376a1de5323cff 2 Nodes configured, 2 expected votes 7 Resources configured. Online: [ ldap1 ldap2 ] Resource Group: IPV_LVS IPV_4 (ocf::heartbeat:IPaddr2): Started ldap1 IPV_6 (ocf::heartbeat:IPv6addr): Started ldap1 lvs (ocf::heartbeat:ldirectord): Started ldap1 Clone Set: clon_IPV_lo [IPV_lo] Started: [ ldap2 ] Stopped: [ IPV_lo:1 ] root@ldap1:/home/mamartin# crm configure show node ldap2 \ attributes standby="off" node ldap1 \ attributes standby="off" primitive IPV-lo_4 ocf:heartbeat:IPaddr \ params ip="192.168.1.10" cidr_netmask="32" nic="lo" \ op monitor interval="5s" primitive IPV-lo_6 ocf:heartbeat:IPv6addrLO \ params ipv6addr="[fc00:1::3]" cidr_netmask="64" \ op monitor interval="5s" primitive IPV_4 ocf:heartbeat:IPaddr2 \ params ip="192.168.1.10" nic="eth0" cidr_netmask="25" lvs_support="true" \ op monitor interval="5s" primitive IPV_6 ocf:heartbeat:IPv6addr \ params ipv6addr="[fc00:1::3]" nic="eth0" cidr_netmask="64" \ op monitor interval="5s" primitive lvs ocf:heartbeat:ldirectord \ params configfile="/etc/ldirectord.cf" \ op monitor interval="20" timeout="10" \ meta target-role="Started" group IPV_LVS IPV_4 IPV_6 lvs group IPV_lo IPV-lo_6 IPV-lo_4 clone clon_IPV_lo IPV_lo \ meta interleave="true" target-role="Started" location cli-prefer-IPV_LVS IPV_LVS \ rule $id="cli-prefer-rule-IPV_LVS" inf: #uname eq ldap1 colocation LVS_no_IPV_lo -inf: clon_IPV_lo IPV_LVS property $id="cib-bootstrap-options" \ dc-version="1.1.7-ee0730e13d124c3d58f00016c3376a1de5323cff" \ cluster-infrastructure="openais" \ expected-quorum-votes="2" \ no-quorum-policy="ignore" \ stonith-enabled="false" \ last-lrm-refresh="1401264327" rsc_defaults $id="rsc-options" \ resource-stickiness="1000" The problem is in the ipvsadm only show a one real IP, when i configured two now, show the ldirector.cf: root@ldap1:/home/mamartin# ipvsadm IP Virtual Server version 1.2.1 (size=4096) Prot LocalAddress:Port Scheduler Flags - RemoteAddress:Port Forward Weight ActiveConn InActConn TCP ldap-maqueta.cica.es:ldap wrr - ldap2.cica.es:ldap Route 4 0 0 TCP [[fc00:1::3]]:ldap wrr - [[fc00:1::2]]:ldap Route 4 0 0 root@ldap1:/home/mamartin# cat /etc/ldirectord.cf checktimeout=10 checkinterval=2 autoreload=yes logfile="/var/log/ldirectord.log" quiescent=yes #ipv4 virtual=192.168.1.10:389 real=192.168.1.11:389 gate 4 real=192.168.1.12:389 gate 4 scheduler=wrr protocol=tcp checktype=on #ipv6 virtual6=[[fc00:1::3]]:389 real6=[[fc00:1::1]]:389 gate 4 real6=[[fc00:1::2]]:389 gate 4 scheduler=wrr protocol=tcp checkport=389 checktype=on and in the logs I see nothing clear: root@ldap1:/home/mamartin# ldirectord -d /etc/ldirectord.cf start DEBUG2: Running system(/sbin/ipvsadm -a -t 192.168.1.10:389 -r 192.168.1.11:389 -g -w 0) Running system(/sbin/ipvsadm -a -t 192.168.1.10:389 -r 192.168.1.11:389 -g -w 0) DEBUG2: Quiescent real server: 192.168.1.11:389 (192.168.1.10:389) (Weight set to 0) Quiescent real server: 192.168.1.11:389 (192.168.1.10:389) (Weight set to 0) DEBUG2: Disabled real server=on:tcp:192.168.1.11:389:::4:gate:\/: (virtual=tcp:192.168.1.10:389) DEBUG2: Running system(/sbin/ipvsadm -a -t 192.168.1.10:389 -r 192.168.1.12:389 -g -w 0) Running system(/sbin/ipvsadm -a -t 192.168.1.10:389 -r 192.168.1.12:389 -g -w 0) DEBUG2: Quiescent real server: 192.168.1.12:389 (192.168.1.10:389) (Weight set to 0) Quiescent real server: 192.168.1.12:389 (192.168.1.10:389) (Weight set to 0) DEBUG2: Disabled real server=on:tcp:192.168.1.12:389:::4:gate:\/: (virtual=tcp:192.168.1.10:389) DEBUG2: Checking on: Real servers are added without any checks DEBUG2: Resetting soft failure count: 192.168.1.12:389 (tcp:192.168.1.10:389) Resetting soft failure count: 192.168.1.12:389 (tcp:192.168.1.10:389) DEBUG2: Running system(/sbin/ipvsadm -a -t 192.168.1.10:389 -r 192.168.1.12:389 -g -w 4) Running system(/sbin/ipvsadm -a -t 192.168.1.10:389 -r 192.168.1.12:389 -g -w 4) Destination already exists root@ldap1:/home/mamartin# cat /var/log/ldirectord.log [Tue Jun 3 09:39:29 2014|ldirectord.cf|19266] Quiescent real server: 192.168.1.11:389 (192.168.1.10:389) (Weight set to 0) [Tue Jun 3 09:39:29 2014|ldirectord.cf|19266] Quiescent real server: 192.168.1.12:389 (192.168.1.10:389) (Weight set to 0) [Tue Jun 3 09:39:29 2014|ldirectord.cf|19266] Resetting soft failure count: 192.168.1.12:389 (tcp:192.168.1.10:389) [Tue Jun 3 09:39:29 2014|ldirectord.cf|19266] system(/sbin/ipvsadm -a -t 192.168.1.10:389 -r 192.168.1.12:389 -g -w 4) failed: [Tue Jun 3 09:39:29 2014|ldirectord.cf|19266] Added real server: 192.168.1.12:389 (192.168.1.10:389) (Weight set to 4) [Tue Jun 3 09:39:29 2014|ldirectord.cf|19266] Resetting soft failure count: 192.168.1.11:389 (tcp:192.168.1.10:389) [Tue Jun 3 09:39:29 2014|ldirectord.cf|19266] Restored real server: 192.168.1.11:389 (192.168.1.10:389) (Weight set to 4) [Tue Jun 3 09:39:29 2014|ldirectord.cf|19266] Resetting soft failure count: [[fc00:1::2]]:389 (tcp:[[fc00:1::3]]:389) [Tue Jun 3 09:39:29 2014|ldirectord.cf|19266] system(/sbin/ipvsadm -a -t [[fc00:1::3]]:389 -r [[fc00:1::2]]:389 -g -w 4) failed: [Tue Jun 3 09:39:29 2014|ldirectord.cf|19266] Added real server: [[fc00:1::2]]:389 ([[fc00:1::3]]:389) (Weight set to 4) [Tue Jun 3 09:39:29 2014|ldirectord.cf|19266] Resetting soft failure count: [[fc00:1::1]]:389 (tcp:[[fc00:1::3]]:389) [Tue Jun 3 09:39:29 2014|ldirectord.cf|19266] Restored real server: [[fc00:1::1]]:389 ([[fc00:1::3]]:389) (Weight set to 4) do not know if this is a bug or a configuration error, can anyone help? Regards.

    Read the article

  • Serial converter - cat /dev/ttyUSB0 hangs on open

    - by Alex
    I am using Ubuntu 11.04 and attached a Garmin data cable. The device gets recognized [17718.502138] USB Serial support registered for pl2303 [17718.502181] pl2303 2-1:1.0: pl2303 converter detected [17718.513416] usb 2-1: pl2303 converter now attached to ttyUSB0 [17718.513443] usbcore: registered new interface driver pl2303 [17718.513446] pl2303: Prolific PL2303 USB to serial adaptor driver ... but when I do a strace cat /dev/ttyUSB0 it hangs on the open part and does not continue any more open("/dev/ttyUSB0", O_RDONLY|O_LARGEFILEC If I do the same on Ubuntu 12.04 it stops on fread(" ... ") which is okay, as there is currently no data comming in at this port. I am not sure if it is just a different configuration of the system or an driver related problem. How can I track this down further? Unfortunately I can not update the old Ubuntu 11.04 system for different reasons at the moment.

    Read the article

  • DDNS Not Creating Journal (Dhcpd and Named)

    - by user130094
    * EDIT 1 * After monkeying with additional debug logging I see some log entries of interest. 27-Jul-2012 23:45:26.537 general: error: zone example.lan/IN/internal: journal rollforward failed: no more 27-Jul-2012 23:45:26.537 general: error: zone example.lan/IN/internal: not loaded due to errors. ^^^ If I can remedy the above messages I think I'll be good to go ^^^ * EDIT 2 * Grasping at straws I touched a forward and a reverse zone journal file and restarted named. Boom! Works. Despite documentation stating the files are created automatically and what I have seen before... dunno why but that did the trick. Also re-checked perms on the dir the files live in. As certain as I was, they were correct with named having rw. CentOS 6 (final) dhcpd 4.1.1-P1 named BIND 9.8.2rc1-RedHat-9.8.2-0.10.rc1.el6 Basic DHCP and DNS functionality are in place on 192.168.111.2. Clients are assigned addresses as intended and can resolve local DNS names as well as Internet names. My problem is that named's zone journal files are not created. chroot: /var/named/chroot I tried placing the zone files in various directories (/var/named/data, /var/named, /var/named/dynamic - no matter which dir with named owning and wide open perms I now get nowhere). Along the way I, at one point, got a permission denied when named tried to create the journal. Resolved the issue by: chown --recursive named:named /var/named chmod --recursive 777 /var/named The journal was then created and here's where things fell apart. I attempted to tame permissions to something more sane and broke it. Once changed and having restarted named it threw an error indicating the journal was out of sync (or something to that affect)... didn't matter since this is a new setup so I deleted it and now it is not recreated. Now though I see no errors in /var/log/messages, my chrooted /var/log/named.log, or chrooted /var/log/named.debug. I increased the debug level with 'rndc trace' - no love. Increased trace to 10, still nothing. SELinux is disabled... [root@server temp]# sestatus SELinux status: disabled dhcpd.conf... allow client-updates; ddns-update-style interim; subnet 192.168.111.0 netmask 255.255.255.224 { ... key dhcpudpate { algorithm hmac-md5; secret LDJMdPdEZED+/nN/AGO9ZA==; } zone example.lan. { primary 192.168.111.2; key dhcpudpate; } } named.conf... key dhcpudpate { algorithm hmac-md5; secret "LDJMdPdEZED+/nN/AGO9ZA=="; }; zone "example.lan" { type master; file "/var/named/dynamic/example.lan.db"; allow-transfer { none; }; allow-update { key dhcpudpate; }; notify false; check-names ignore; }; The following shows /var/log/named.log output of named starting up - no errors. 27-Jul-2012 21:33:39.349 general: info: zone 111.168.192.in-addr.arpa/IN/internal: loaded serial 2012072601 27-Jul-2012 21:33:39.349 general: info: zone example.lan/IN/internal: loaded serial 2012072501 27-Jul-2012 21:33:39.350 general: info: zone example2.lan/IN/internal: loaded serial 2012072501 27-Jul-2012 21:33:39.350 general: info: zone example3.lan/IN/internal: loaded serial 2012072601 27-Jul-2012 21:33:39.350 general: info: zone example4.lan/IN/internal: loaded serial 2012072501 27-Jul-2012 21:33:39.351 general: info: zone example5.lan/IN/internal: loaded serial 2012072501 27-Jul-2012 21:33:39.351 general: info: managed-keys-zone ./IN/internal: loaded serial 0 27-Jul-2012 21:33:39.351 general: info: zone example.lan/IN/external: loaded serial 2012072501 27-Jul-2012 21:33:39.352 general: info: zone example1.lan/IN/external: loaded serial 2012072501 27-Jul-2012 21:33:39.352 general: info: zone example2.lan/IN/external: loaded serial 2012072501 27-Jul-2012 21:33:39.352 general: info: zone example3.lan/IN/external: loaded serial 2012072501 27-Jul-2012 21:33:39.353 general: info: managed-keys-zone ./IN/external: loaded serial 0 27-Jul-2012 21:33:39.353 general: notice: running 27-Jul-2012 21:34:03.825 general: info: received control channel command 'trace 10' 27-Jul-2012 21:34:03.825 general: info: debug level is now 10 ...and /var/log/messages for a named start... Jul 27 23:02:04 server named[9124]: ---------------------------------------------------- Jul 27 23:02:04 server named[9124]: BIND 9 is maintained by Internet Systems Consortium, Jul 27 23:02:04 server named[9124]: Inc. (ISC), a non-profit 501(c)(3) public-benefit Jul 27 23:02:04 server named[9124]: corporation. Support and training for BIND 9 are Jul 27 23:02:04 server named[9124]: available at https://www.isc.org/support Jul 27 23:02:04 server named[9124]: ---------------------------------------------------- Jul 27 23:02:04 server named[9124]: adjusted limit on open files from 4096 to 1048576 Jul 27 23:02:04 server named[9124]: found 2 CPUs, using 2 worker threads Jul 27 23:02:04 server named[9124]: using up to 4096 sockets Jul 27 23:02:04 server named[9124]: loading configuration from '/etc/named.conf' Jul 27 23:02:04 server named[9124]: using default UDP/IPv4 port range: [1024, 65535] Jul 27 23:02:04 server named[9124]: using default UDP/IPv6 port range: [1024, 65535] Jul 27 23:02:04 server named[9124]: listening on IPv4 interface eth0, 192.168.111.2#53 Jul 27 23:02:04 server named[9124]: generating session key for dynamic DNS Jul 27 23:02:04 server named[9124]: sizing zone task pool based on 12 zones Jul 27 23:02:04 server named[9124]: set up managed keys zone for view internal, file 'dynamic/3bed2cb3a3acf7b6a8ef408420cc682d5520e26976d354254f528c965612054f.mkeys' Jul 27 23:02:04 server named[9124]: set up managed keys zone for view external, file 'dynamic/3c4623849a49a53911c4a3e48d8cead8a1858960bccdea7a1b978d73ec2f06d7.mkeys' Jul 27 23:02:04 server named[9124]: command channel listening on 127.0.0.1#953 What can I do to troubleshoot this further? It almost seems as though dhcpd is not triggering the update. Maybe I should troubleshoot here and, if so, how? Many thanks.

    Read the article

  • How can I use an SSH tunnel for all traffic from a single application, without knowing the ports used?

    - by Matthew Read
    I have an application that opens connections on dozens of ports, and doesn't provide documentation about which ports it uses. I could use Wireshark or something to capture the traffic and export the ports from that, but I think it should be simpler than that. (And I'm not sure I would be able to cover all use cases and ensure the app used every single port it can ever use.) So I'm looking for a way to just say "forward all traffic from this application" (bonus points for all traffic from child processes as well) without needing to worry about specific ports. I'm sure there must be a way, but I couldn't hit on the right keywords while searching Google. How can I do this?

    Read the article

  • How do ISPs/Colocation Facilities limit bandwidth for Ethernet Drops?

    - by Kyle Brandt
    I have switch providers and have run into some problems with bandwidth limitations. I have more bandwidth then before, but there are performance issues. The router is connected to a 100mBit port, but they limit it to arbitrary settings (in software I imagine). It seems when I go above the limit, the provider starts to drop packets beyond the limit (This is what they said they do as well). Is it possible the previous provider did something like queuing packets above the this limit before dropping them? Is anyone aware of not only what can be done, but what is typical? Also, is there anything I can do on my Cisco router to help this situation? It would seem I am pretty helpless if the packets are dropped before they reach my interface (The traffic that is high is inbound to my network).

    Read the article

  • How do you create a virtual directory in Mac Snow Leopard?

    - by johnny
    I am using the server admin tool for the web and see where I can create sites with the +. I thought that was creating virtual directory but it doesn't seem to be. I need a site that uses port 80 but is like http://myserver/myvirtual instead of http://myserver which is what this one with the + does. how do I make a virtual directory with the tool like in IIS? Thank you. edit: how can I put a bounty on this?

    Read the article

  • help building a PC that can image a dozen hard drives simultaneously

    - by Bigbio2002
    Not sure if this belongs on here or SuperUser, but here goes... I'm trying to figure out how to make a mass hard drive imaging PC out of COTS parts. A dedicated imaging device can do 10 drives at a time, but costs several thousand dollars. So far, I'm thinking to use several 3-port PCI-E Firewire cards, and use some kind of Firewire-to-IDE adapter to connect the drives themselves. The "software" would consist of scripting diskpart, or some other imaging utility. The problem is that I can't seem to find any sort of adapter. I could use standard external hard drive bays, but then I'd have a dozen power cables that I need to plug in. Ugly, messy, and inefficient. I picked Firewire over USB not only for better transfer speeds, but also because FW can deliver power over the bus (and could theoretically power a hard drive). Does anyone have any input on this?

    Read the article

  • IP camera's multicast/RTSP conflicting with 2.4GHz Wi-Fi?

    - by jayson
    Here at our business we have a Netgear R7000 running DD-WRT. I have been slowly adding IP cameras which I run using Blue Iris software. The last camera I bought (which is NOT a wireless camera), when I plug it into the network I start having really bad connection issues on the 2.4GHz Wi-Fi network. The 5GHz works fine, just the 2.4GHz all of the sudden has trouble connecting, as if it's conflicting. I've tried playing with the camera settings, different IP addresses, HTTP ports, etc, and discovered it to be a conflict with multicast. When multicast is checked, the Wi-Fi has issues but my video streams via Blue Iris. When unchecked, Wi-Fi works fine but the video won't stream through Blue Iris. The problem is there are no settings in the camera to change the RTSP port, which is set to 34567. Does anyone know something that could fix this issue? It all seems very strange to me but maybe someone has an idea?

    Read the article

  • How to connect MySQL database of local server in NetBeans 7.0.1 ( windows)?

    - by diEcho
    Hello All, I am using NetBeans IDE 7.0.1 on Windows 7 very first time for my php. Actually in my company there is a local server ( 192.168.1.99) where all projects resides and we access phpmyadmin of that local server, Although I have added my project folders with NetBeans (this was also very hectic) but now I am having problem to connect database of my local server as I can see 192.168.1.99/phpmyadmin through my browser. I have set below value Server Host : localhost, Server port number : 3306, Administrator username : keshav Administrator password : ****** and when i click on connect, a popup error windows appears with below text Unable to connect to the MySQL server: org.netbeans.api.db.explorer.DatabaseException: org.netbeans.api.db.explorer.DatabaseException: java.sql.SQLException: Access denied for user 'keshav'@'localhost' (using password: YES). The server may not be running or your MySQL connection properties may not be set correctly. Do you want to edit your MySQL connection properties? Please help me out. Thanks

    Read the article

  • Computer sending data while turned of

    - by Nicklas Ansman
    I have a some what strange problem (which could have and easy and obvious solution for all I know). My problem is that when I've booted ubuntu (now 10.4 but same problem with 9.10) and turns it off it starts sending a HUGE amount of data via the ethernet cable, so much in fact that my router can't handle it and stops responding. As far as I can tell the computer is completely turned off with no fans spinning. I can add that if I boot windows I do not have this problem, just when exiting ubuntu. There are two "fixes" for my problem: Pull the ethernet cable until the next boot Turn off power to the PSU and wait for the capacitors to unload Is there anyone who knows what could be going on? I'd be happy to post some logs or conf-files. Currently I'm using the ethernet port on my motherboard which is a Asus P6T Deluxe V2 with an updated version of the BIOS (maybe not the latest but since it only happens when I've been in ubuntu I don't wanna mess with the BIOS too much). Regards Nicklas

    Read the article

  • Dovecot, POP3 and Gmail

    - by Eric J.
    I setup Postfix and Dovecot on a new Ubuntu box following these directions. From a client machine, I validate that POP3 seems to be working telnet mydomain.com 110 +OK Dovecot ready. USER [email protected] +OK PASS mypassword +OK Logged in. quit +OK Logging out. However, when trying to configure Gmail on the same client to retrieve email via POP3, I get the error Server denied POP3 access for the given username and password. Server returned error: "Login failed." I carefully confirmed that Gmail is configured to use the same POP Server, Port, Username and Password I used when checking the connection with telnet. What could be causing Gmail to get a "Login failed" message?

    Read the article

  • FM Transmitter for the Home

    - by greggannicott
    After asking this question regarding piping music through my home I'm looking to buy an FM transmitter. I'd like to connect it to my home pc (ie. into the speaker port), and I'd then control the output with my iPhone (ie. using Apple's Remote software). The problem is, given that almost every FM transmitter is advertised to be used in the car (ie. an iTrip) it's proving very tricky knowing which one would be ideal for the home. First, has anyone tried this? Did it work ok or was there simply to much interference for it work. Secondly, if it did work ok, can anyone recommend a reasonable transmitter? For what I need it seems like an ideal solution, so given that I'm struggling to find information regarding it I'm starting to believe it's not as ideal as it first seems. Thanks in advanance.

    Read the article

  • Can't display at full resolution on an external monitor from my MacBook.

    - by Ramblingwood
    I have a 24" Asus V246H and a new MacBook ($999 one). I am trying to display to display to my Asus at 1080p via VGA. So I boot up with the lid closed and the external monitor plugged in. Everything boots up fine, but the resolution is really low. So I go in and change the resolution to be 1920x1080. My monitor then has a blue box on it that says "OUT OF RANGE". Lower resolutions like 1024x768 work, but 1680x1050 doesn't. If I try mirroring my displays, the entire external monitor AND the entire laptop screen is completely garbled. I can make out some colors, but it is completely unusable. I am suspecting that it simply won't work via VGA, but I don't want to buy another adapter, and my PC is using the DVI port. Any solutions?

    Read the article

  • IIS 5 default website (Stopped) after new install on new box

    - by unknown (yahoo)
    We just got new boxes at work. Running Xp, IIs 5.1 (yeah I know corporate decision, not mine) when I go look at inetmgr (iis) the default website it stopped. if restarted, I get an error that it didn't respond in a timely manor I ran netstat -an, and -o and saw nothing had port 80 open. cleared my event viewer, restarted iis and restarted iisadmin service (and theirby smtp) no errors in the event log. I ran aspnet_regiis -i jsut in case. Still no joy. I'm stumped. Can any think of anything else to try? Thanks, E-

    Read the article

  • Speakers will not work after I use USB Headset

    - by Josh K
    I am trying to configure my SteelSeries Siberia V2 Frost USB Headset to work with my 2.0 speakers using a jack. My goal is to find a easy way (no restart) to switch playback from my headset and my speakers and vice-versa. If i plug my headset in and make it the default device then restart my application/web page then the sounds works out of headset. If I switch the default to my speakers and restart apps/web pages then sound does not play. I know my speakers are on because if I configure them through windows and test, the sounds play, and sounds also play when I test it through my audio manager. Even if I unplug my headset, I still cannot get sound out of my speakers unless I restart My audio manager is RealTek HD Audio Manager, Windows 7 x64. I have tried the speaker back, usb front. speaker front, usb in front port. I have not tried speaker back, usb back.

    Read the article

  • postfix, webmin installed. whats next?

    - by Johnny Craig
    Im trying to get imap running and dont know the problem. i a developer, not a network guy.( our network guy left) we had postfix installed already for outgoing mail on 8 domains. we only had incoming on 1 domain. but that mail server is located on a different ip. now we want incoming on another domain, but we dont want it on another ip, we want it on the same ip as the website itself. I installed dovecot today because my hosting company said i needed it. it seems to run fine. do i need dovecot AND postfix? or are they the same thing? dovecot does not show up anywhere in webmin what i cant seem to figure out how to do is add a user email so i can try to telnet in on port 143. i think i have evrything installed, just need the next step.... sorry for the newb question

    Read the article

  • Mikrotik queues and limiting total upstream bandwidth

    - by g18c
    With a Mikrotik router (form of embedded Linux) I have created simple queues per machine matched by source IP address. Each of the 4 machine queues has an unlimited burst 3Mbps/3Mbps for Tx/Rx. During speedtest.net on all 4 machines at the same time, each machine shows 3Mbps (and is limited correctly there), however the total bandwidth on the uplink goes to 12Mbps (i need to set this to 10Mbps max for the upstream). I want to restrict the actual traffic passing across the uplink port to 10Mbps regardless of what the other queues are doing (I need this catch all queue to have the final say on the uplink speed). For example I need: Scenario A Machine A transferring @ 3Mbps Machine B transferring @ 3Mbps Machine C transferring @ 3Mbps Machine D transferring @ 0Mbps Up-link speed = 9Mbps Scenario B Machine A trying to transfer @ 3Mbps Machine B trying to transfer @ 3Mbps Machine C trying to transfer @ 3Mbps Machine D trying to transfer @ 3Mbps Up-link speed = 10Mbps Actual transfer speed of machine A,B,C,D = 2.5Mbps This is to allow slight over subscription of bandwidth queues as not all will be transmitting at 3Mbps all the time. Is this possible and if so how would one go about doing this?

    Read the article

< Previous Page | 310 311 312 313 314 315 316 317 318 319 320 321  | Next Page >