Search Results

Search found 23208 results on 929 pages for 'event loop'.

Page 317/929 | < Previous Page | 313 314 315 316 317 318 319 320 321 322 323 324  | Next Page >

  • SQL Stored Procedure

    - by Nathan
    I am trying to run a stored procedure with a while loop in it using Aqua Data Studio 6.5 and as soon as the SP starts Aqua Data starts consuming an increasing amount of my CPU's memory which makes absolutely no sense to me because everything should be off on the Sybase server I am working with. I have commented out and tested every piece of the SP and narrowed the issue down to the while loop. Can anyone explain to me what is going on? create procedure sp_check_stuff as begin declare @counter numeric (9), @max_id numeric (9), @exists numeric (1), @rows numeric (1) select @max_id = max(id) from my_table set @counter = 0 set @exists = 0 set @rows = 0 while @count <= @max_id begin //More logic which doesn't affect memory usage based //on commenting it out and running the SP set @counter = @counter + 1 set @exists = 0 set @rows = 0 end end return

    Read the article

  • ant: iterator over properties file

    - by scheibenkleister
    Hi, all my projects and their versions are defined in a properties file like this: ProjectNameA=0.0.1 ProjectNameB=1.4.2 I'd like to iterate over all projects and use there names and versions in an ant script. Right now, I read the entire properties file in help of the property task. Then I iterate over a given list in a for loop like this: <for list="ProjectNameA,ProjectNameB" param="project"> <sequential> <echo message="@{project} has version ${@{project}}" /> </sequential> </for> How can I avoid the duplication of the project names in the for loop. So basically iterate over each line and extract the name and the version of a project. Thanks.

    Read the article

  • php nested for statements?

    - by Dashiell0415
    I'm trying to process a for loop within a for loop, and just a little wary of the syntax... Will this work? Essentially, I want to run code for every 1,000 records while the count is equal to or less than the $count... Will the syntax below work, or is there a better way? for($x = 0; $x <= 700000; $x++) { for($i = 0; $i <= 1000; $i++) { //run the code } }

    Read the article

  • How to read piped input in Perl?

    - by Jenni
    I am trying to create something in Perl that is basically like the Unix "tee" command. I'm trying to read each line of STDIN, run a substitution on it, and print it. (And eventually, also print it to a file.) This works if I'm using console input, but if I try to pipe input to the command it doesn't do anything. Here's a simple example: print "about to loop\n"; while(<STDIN>) { s/2010/2009/; print; } print "done!\n"; I try to pipe the dir command to it like this: C:\perltestdir | mytee.pl about to loop done! Why is it not seeing the piped input?

    Read the article

  • calling same function on different buttons not loaded yet

    - by Jordan Faust
    I can not get this to work for every button and I cannot find anything explaining why. I guessing it is something small that I am missing $(document).ready(function() { // delete the selected row from the database $(document).on('click', '#business-area-delete-button', { model: "BusinessArea" }, deleteRow); $(document).on('click', '#business-type-delete-button', { model: "BusinessType" }, deleteRow); $(document).on('click', '#client-delete-button', { model: "Client" }, deleteRow); $(document).on('click', '#client-type-delete-button', { model: "ClientType" }, deleteRow); $(document).on('click', '#communication-channel-type', { model: "CommunicationChannelType" }, deleteRow); $(document).on('click', '#parameter-type-delete-button', { model: "ParameterType" }, deleteRow); $(document).on('click', '#validation-method-delete-button', { model: "ValidationMethod" }, deleteRow); } the event function deleteRow(event){ $.ajax( { type:'POST', data: { id: $(".delete-row").attr("id") }, url:"/mysite/admin/delete" + event.data.model, success:function(data,textStatus){ $('#main-content').html(data); }, error:function(XMLHttpRequest,textStatus,errorThrown){ jQuery('#alerts').html(XMLHttpRequest.responseText); }, complete:function(XMLHttpRequest,textStatus){ placeAlerts() } } ); return false }; This works only for a the button with id validation-method-delete-button. I use document and not the button its self because the button is contained in a template that is loaded later via ajax. I have this working for a similar function that is selecting a row in a table however I am not attempting to pass data in that scenario.

    Read the article

  • best way to prgram php and mysql query

    - by air
    most of times in our pages we need to print only 1 field value of table in loop. for example <?php for($i=1;$i<=mysql_num_rows($result);$i++) { echo $row['name']; $sql1="select industry from table_industry where profid='".$row['prof']."'"; $result1=mysql_query($sql1); $row1=mysql_fetch_array($result1); echo $row1['industry']; ?> } ?> above is one PHP code just for example where we think that $row['prof'] carry value of profession ID and we print profession of each person. for example we have 5000+ record in table and above loop will execute for 5000+ times what will be the best way to print value of industry field from table table_industry Same code which i write above ? any other php code suggestion for faster execution and less use of resources? Thanks

    Read the article

  • C++ Detecting ENTER key pressed by user

    - by user69514
    I have a loop where I ask the user to enter a name. I need to stop when the user presses the ENTER key..... or when 20 names have been entered. However my method doesn't stop when the user presses the ENTER key //loop until ENTER key is entered or 20 elements have been added bool stop = false; int ind = 0; while( !stop || ind >= 20 ){ cout << "Enter name #" << (ind+1) << ":"; string temp; getline(cin, temp); int enterKey = atoi(temp.c_str()); if(enterKey == '\n'){ stop = true; } else{ names[ind] = temp; } ind++; }

    Read the article

  • R: building a simple command line plotting tool/Capturing window close events

    - by user275455
    I am trying to use R within a script that will act as a simple command line plot tool. I.e. user pipes in a csv file and they get a plot. I can get to R fine and get the plot to display through various temp file machinations, but I have hit a roadblock. I cannot figure out how to get R to keep running until the users closes the window. If I plot and exit, the plot disappears immediately. If I plot and use some kind of infinite loop, the user cannot close the plot; he must exit by using an interrupt which I don't like. I see there is a getGraphicsEvent function, but it claims that the device is not supported (X11). Anyway, it doesn't appear to actually support an onClose event, only onMouseDown. Any ideas on how to solve this? edit: Thanks to Dirk for the advice to check out the tk interface. Here is the test code that works: require(tcltk) library(tkrplot) ##function to display plot, called by tkrplot and embedded in a window plotIt<-function(){ plot(x=1:10, y=1:10) } ##create top level window tt<-tktoplevel() ##variable to wait on like a condition variable, to be set by event handler done <- tclVar(0) ##bind to the window destroy event, set done variable when destroyed tkbind(tt,"",function() tclvalue(done) <- 1) ##Have tkrplot embed the plot window, then realize it with tkgrid tkgrid(tkrplot(tt,plotIt)) ##wait until done is true tkwait.variable(done)

    Read the article

  • PreparedStatement and 'null' value in WHERE clause

    - by bond
    I am using PrepareStatement and BatchUpdate for executimg a UPDATE query. In for loop I create a Batch. At end of loop I execute batch. Above logic works fine if SQL query used in PrepareStatement does not have null values in WHERE claues. Update Statement fails if there is null value in WHERE clasue. My code looks something like this, connection = getConnection(); PreparedStatement ps = connection.prepareStatement("UPDATE TEST_TABLE SET Col1 = true WHERE Col2 = ? AND Col3 = ?") for (Data aa : InComingData) { if(null == aa.getCol2()) { ps.setNull(1, java.sql.Types.INTEGER); } else { ps.setInteger(1,aa.getCol2()) } if(null == aa.getCol3()) { ps.setNull(2, java.sql.Types.INTEGER); } else { ps.setInteger(2,aa.getCol3()) } ps.addBatch(); } ps.executeBatch(); connection.commit(); Any help would be appreciated.

    Read the article

  • reading csv file without for

    - by Abruzzo Forte e Gentile
    Hi All I need to read a CSV file in python. Since for last row I receive a 'NULL byte' error I would like to avoid using for keyword but the while. Do you know how to do that? reader = csv.reader( file ) for row in reader # I have an error at this line # do whatever with row I want to substitute the for-loop with a while-loop so that I can check if the row is NULL or not. What is the function for reading a single row in the CSV module? Thanks Thanks p.S. below the traceback Traceback (most recent call last): File "FetchNeuro_TodayTrades.py", line 189, in for row in reader: _csv.Error: line contains NULL byte

    Read the article

  • How do I resolve this scope issue in VB .NET?

    - by froadie
    I have a code structure something like this: For row = 1 To numRows Dim arrayIndex As Integer = 0 For column As Integer = bucketStartColumn To bucketEndColumn ' whatever code arrayIndex = arrayIndex + 1 Next Next Dim arrayIndex As Integer = 0 For column As Integer = bucketStartColumn To bucketEndColumn ' whatever code arrayIndex = arrayIndex + 1 Next Not exactly the code, so I don't really need suggestions about refactoring, but my problem is this - with this code I get a compiler error for the first Dim arrayIndex As Integer = 0 - "Variable 'arrayIndex' hides a variable in an enclosing block." As far as I can tell, arrayIndex is local to the first for loop and shouldn't exist by the time we reach the second loop. If I try to change the second declaration of arrayIndex to arrayIndex = 0, I get the error "Name 'arrayIndex' is not declared", as I expected. So is it visible, or not? Does this have something to do with the Dim keyword? Any suggestions of how to get around this, other than naming the second index variable something else?

    Read the article

  • breaking out from socket select

    - by kamziro
    I have a loop which basically calls this every few seconds (after the timeout): while(true){ if(finished) return; switch(select(FD_SETSIZE, &readfds, 0, 0, &tv)){ case SOCKET_ERROR : report bad stuff etc; return; default : break; } // do stuff with the incoming connection } So basically for every few seconds (which is specified by tv), it reactivates the listening. This is run on thread B (not a main thread). There are times when I want to end this acceptor loop immediately from thread A (main thread), but seems like I have to wait until the time interval finishes.. Is there a way to disrupt the select function from another thread so thread B can quit instantly?

    Read the article

  • How to iterate through an XDocument's Nodes

    - by Ed R
    I am trying to iterate through my xml document's nodes to get the value for <username>Ed</username> in each node. I am using Linq to sort the XDocument first, then attempting to loop through the nodes. I can't seem to find the correct foreach loop to achieve this. Any help is appreciated. var doc = XDocument.Load("files\\config.xml"); var newDoc = new XDocument(new XElement("Config", from p in doc.Element("Config").Elements("Profile") orderby int.Parse(p.Element("order").Value) select p)); foreach (XElement xe in newDoc.Nodes()) { MessageBox.Show(xe.Element("username").Value); }

    Read the article

  • Thread sleep and thread join.

    - by Dhruv Gairola
    hi guys, if i put a thread to sleep in a loop, netbeans gives me a caution saying Invoking Thread.sleep in loop can cause performance problems. However, if i were to replace the sleep with join, no such caution is given. Both versions compile and work fine tho. My code is below (check the last few lines for "Thread.sleep() vs t.join()"). public class Test{ //Display a message, preceded by the name of the current thread static void threadMessage(String message) { String threadName = Thread.currentThread().getName(); System.out.format("%s: %s%n", threadName, message); } private static class MessageLoop implements Runnable { public void run() { String importantInfo[] = { "Mares eat oats", "Does eat oats", "Little lambs eat ivy", "A kid will eat ivy too" }; try { for (int i = 0; i < importantInfo.length; i++) { //Pause for 4 seconds Thread.sleep(4000); //Print a message threadMessage(importantInfo[i]); } } catch (InterruptedException e) { threadMessage("I wasn't done!"); } } } public static void main(String args[]) throws InterruptedException { //Delay, in milliseconds before we interrupt MessageLoop //thread (default one hour). long patience = 1000 * 60 * 60; //If command line argument present, gives patience in seconds. if (args.length > 0) { try { patience = Long.parseLong(args[0]) * 1000; } catch (NumberFormatException e) { System.err.println("Argument must be an integer."); System.exit(1); } } threadMessage("Starting MessageLoop thread"); long startTime = System.currentTimeMillis(); Thread t = new Thread(new MessageLoop()); t.start(); threadMessage("Waiting for MessageLoop thread to finish"); //loop until MessageLoop thread exits while (t.isAlive()) { threadMessage("Still waiting..."); //Wait maximum of 1 second for MessageLoop thread to //finish. /*******LOOK HERE**********************/ Thread.sleep(1000);//issues caution unlike t.join(1000) /**************************************/ if (((System.currentTimeMillis() - startTime) > patience) && t.isAlive()) { threadMessage("Tired of waiting!"); t.interrupt(); //Shouldn't be long now -- wait indefinitely t.join(); } } threadMessage("Finally!"); } } As i understand it, join waits for the other thread to complete, but in this case, arent both sleep and join doing the same thing? Then why does netbeans throw the caution?

    Read the article

  • Reducing Dimension For SVM in Sensor Network

    - by iinception
    Hi Everyone, I am looking for some suggestions on a problem that I am currently facing. I have a set of sensor say S1-S100 which is triggered when some event E1-E20 is performed. Assume, normally E1 triggers S1-S20, E2 triggers S15-S30, E3 triggers S20-s50 etc and E1-E20 are completely independent events. Occasionally an event E might trigger any other unrelated sensor. I am using ensemble of 20 svm to analyze each event separately. My features are sensor frequency F1-F100, number of times each sensor is triggered and few other related features. I am looking for a technique that can reduce the dimensionality of the sensor feature(F1-F100)/ or some techniques that encompasses all of the sensor and reduces the dimension too(i was looking for some information theory concept for last few days) . I dont think averaging, maximization is a good idea as I risk loosing information(it did not give me good result). Can somebody please suggest what am I missing here? A paper or some starting idea... Thanks in advance.

    Read the article

  • How can I bind to a helper property in Silverlight

    - by Matt
    For the sake of argument, here's a simple person class public class Person : DependencyObject, INotifyPropertyChanged { public event PropertyChangedEventHandler PropertyChanged; public static readonly DependencyProperty FirstNameProperty = DependencyProperty.Register( "FirstName", typeof ( string ), typeof ( Person ), null ); public static readonly DependencyProperty LastNameProperty = DependencyProperty.Register( "LastName", typeof( string ), typeof( Person ), null ); public string FirstName { get { return ( string ) GetValue( FirstNameProperty ); } set { SetValue( FirstNameProperty, value ); if(PropertyChanged != null) PropertyChanged(this, new PropertyChangedEventArgs( "FirstName" )); } } public string LastName { get { return ( string ) GetValue( LastNameProperty ); } set { SetValue( LastNameProperty, value ); if ( PropertyChanged != null ) PropertyChanged( this, new PropertyChangedEventArgs( "LastName" ) ); } } } I want to go about creating a readonly property like this public string FullName { get { return FirstName + " " + LastName; } } How does binding work in this scenario? I've tried adding a DependancyProperty and raised the PropertyChanged event for the fullname. Basically I just want to have a property that I can bind to that returns the fullname of a user whenever the first or last name changes. Here's the final class I'm using with the modifications. public class Person : DependencyObject, INotifyPropertyChanged { public event PropertyChangedEventHandler PropertyChanged; public static readonly DependencyProperty FirstNameProperty = DependencyProperty.Register( "FirstName", typeof ( string ), typeof ( Person ), null ); public static readonly DependencyProperty LastNameProperty = DependencyProperty.Register( "LastName", typeof( string ), typeof( Person ), null ); public static readonly DependencyProperty FullNameProperty = DependencyProperty.Register( "FullName", typeof( string ), typeof( Person ), null ); public string FirstName { get { return ( string ) GetValue( FirstNameProperty ); } set { SetValue( FirstNameProperty, value ); if ( PropertyChanged != null ) { PropertyChanged( this, new PropertyChangedEventArgs( "FirstName" ) ); PropertyChanged( this, new PropertyChangedEventArgs( "FullName" ) ); } } } public string LastName { get { return ( string ) GetValue( LastNameProperty ); } set { SetValue( LastNameProperty, value ); if ( PropertyChanged != null ) { PropertyChanged( this, new PropertyChangedEventArgs( "LastName" ) ); PropertyChanged( this, new PropertyChangedEventArgs( "FullName" ) ); } } } public string FullName { get { return GetValue( FirstNameProperty ) + " " + GetValue( LastNameProperty ); } } }

    Read the article

  • qTip pop ups come in from top left of screen (on first load)

    - by franko75
    Hi, not sure if i'm set things up incorrectly - I don't seem to see anyone else with this problem, but my qTip popups (all ajax loaded content) are loading quite erratically, in that they are often animating in from off screen before appearing in the correct position. Is there a simple solution to this which I may have missed? Thanks again for your help. HTML markup: <span class="formInfo"> <a href="http://localhost/httpdocs/index.php/help/kc_dob" class="jTip" name="" id="dob_help">?</a> </span> qTip initialisation.. //set up for qtip function initQtip() { $('a.jTip').each(function() { $(this).qtip( { content: { // Set the text to an image HTML string with the correct src URL to the loading image you want to use text: '<img src="/media/images/wait.gif" alt="Loading..." />', url: $(this).attr('href') // Use the rel attribute of each element for the url to load }, position: { adjust: { screen: true // Keep the tooltip on-screen at all times } }, show: { when: 'click', solo: true // Only show one tooltip at a time }, hide: 'unfocus', style: { tip: true, // Apply a speech bubble tip to the tooltip at the designated tooltip corner border: { width: 10, radius: 10 }, width: { min: 200, max: 500 }, name: 'light' // Use the default light style } }); //prevent default event on click }).bind('click', function(event){ event.preventDefault(); return false; }); }

    Read the article

  • Show iPad keyboard on select, focus or always (jQuery)

    - by Ryan
    I have a web app that is using jQuery to replace the RETURN key with TAB so that when I user presses return the form is not submitted but rather the cursor moves to the next text field. This works in all browsers but only 1/2 works on the iPad. On the iPad the next field is highlighted but the keyboard is hidden. How can I keep the keyboard visible or force it somehow? Here's my code (thanks to http://thinksimply.com/blog/jquery-enter-tab): function checkForEnter (event) { if (event.keyCode == 13) { currentBoxNumber = textboxes.index(this); if (textboxes[currentBoxNumber + 1] != null) { nextBox = textboxes[currentBoxNumber + 1] nextBox.focus(); nextBox.select(); event.preventDefault(); return false; } } } Drupal.behaviors.formFields = function(context) { $('input[type="text"]').focus(function() { $(this).removeClass("idleField").addClass("focusField"); }); $('input[type="text"]').blur(function() { $(this).removeClass("focusField").addClass("idleField"); }); // replaces the enter/return key function with tab textboxes = $("input.form-text"); if ($.browser.mozilla) { $(textboxes).keypress (checkForEnter); } else { $(textboxes).keydown (checkForEnter); } };

    Read the article

  • Building a DataTable in C# with one column at a time

    - by Awaken
    I am trying to build a Retirement Calculator as a chance to make something useful and learn C# better. Currently, I am trying to build a DataTable with a dynamic amount of rows/columns. For context, I ask the user for some inputs regarding salary, % of salary being invested, and expected ROI. I have some other stuff too, but it isn't really part of the issue I am having. Because the number of columns I need for the DataTable is unknown until the formula is run (while+for loop completes), I am having trouble doing things as DataColumns. Hopefully the code below will help. I am really trying to build the table one column at a time. I realize I could reverse it to build it one row at a time because the Years before retirement (yearsRetire) is known, but I would prefer not to and I want to learn more. Sorry for the indentation and commenting. I tried to leave some of my commented coding attempts in there. Thanks for any help. public double calcROI() { double testROI = 0.00; double tempRetireAmount = 0; double adjustRetire = goalAmount * (1 + (Math.Pow(inflation,yearsRetire))); // Loop through ROI values until the calculated retire amount with the test ROI // is greater than the target amount adjusted for inflation while (tempRetireAmount < adjustRetire) { //Increment ROI by 1% per while iteration testROI += .01; //Make a new Column to hold the values for ROI for this while iteration //dtMain.Columns.Add(Convert.ToString(testROI)); //DataColumn tempdc = new DataColumn(Convert.ToString(testROI)); //Loop through the number of years entered by user and see the amount //at Retirement with current ROI for (int i = 0; i < yearsRetire; i++) { //Main formula to calculate amount after i years tempRetireAmount = (tempRetireAmount + salary*savingsPct) * (1 + testROI); // Add value for this year/ROI to table/column //DataRow dr = .NewRow(); //dr tempRetireAmount; //tempdc[i] = tempRetireAmount; } //Need to add column of data to my Main DataTable //dtMain.Rows.Add(dr); //dtMain.Columns.Add(tempdc); } return testROI; }

    Read the article

  • How to get array keys in Javascript?

    - by DisgruntledGoat
    I have an array created with this code: var widthRange = new Array(); widthRange[46] = { sel:46, min:0, max:52 }; widthRange[66] = { sel:66, min:52, max:70 }; widthRange[90] = { sel:90, min:70, max:94 }; I want to get each of the values 46, 66, 90 in a loop. I tried for (var key in widthRange) but this gives me a whole bunch of extra properties (I assume they are functions on the object). I can't use a regular for loop since the values are not sequential.

    Read the article

  • MySQL query problem

    - by Luke
    Ok, I have the following problem. I have two InnoDB tables: 'places' and 'events'. One place can have many events, but event can be created without entering place. In this case event's foreign key is NULL. Simplified structure of the tables looks as follows: CREATE TABLE IF NOT EXISTS `events` ( `id` int(11) unsigned NOT NULL AUTO_INCREMENT, `name` varchar(255) COLLATE utf8_bin NOT NULL, `places_id` int(9) unsigned DEFAULT NULL, PRIMARY KEY (`id`), KEY `fk_events_places` (`places_id`), ) ENGINE=InnoDB; ALTER TABLE `events` ADD CONSTRAINT `events_ibfk_1` FOREIGN KEY (`places_id`) REFERENCES `places` (`id`) ON DELETE CASCADE ON UPDATE NO ACTION; CREATE TABLE IF NOT EXISTS `places` ( `id` int(9) unsigned NOT NULL AUTO_INCREMENT, `name` varchar(255) COLLATE utf8_bin NOT NULL, PRIMARY KEY (`id`), ) ENGINE=InnoDB; Question is, how to construct query which contains name of the event and name of the corresponding place (or no value, in case there is no place assigned?). I am able to do it with two queries, but then I am visibly separating events which have place assigned from the ones that are without place. Help really appreciated.

    Read the article

  • Searching within an array of strings...

    - by SoLoGHoST
    Ok, I'm feeling retarded here, I have a string like so: $string = 'function module_testing{'; or it could be like this: $string = 'function module_testing'; And than I have an array of strings like so: $string_array = array('module_testing', 'another_function', 'and_another_function'); Now, is there some sort of preg_match that I can do to test if any of the $string_array values are found within the $string string at any given position? So in this situation, there would be a match. Or is there a better way to do this? I can't use in_array since it's not an exact match, and I'd rather not do a foreach loop on it if I can help it, since it's already in a while loop. Thanks :)

    Read the article

  • How to search for duplicate values in a huge text file having around Half Million records

    - by Shibu
    I have an input txt file which has data in the form of records (each row is a record and represents more or less like a DB table) and I need to find for duplicate values. For example: Rec1: ACCOUNT_NBR_1*NAME_1*VALUE_1 Rec2: ACCOUNT_NBR_2*NAME_2*VALUE_2 Rec3: ACCOUNT_NBR_1*NAME_3*VALUE_3 In the above set, the Rec1 and Rec2 are considered to be duplicates as the ACCOUNT NUMBERS are same(ACCOUNT_NBR1). Note: The input file shown above is a delimiter type file (the delimiter being *) however the file type can also be a fixed length file where each column starts and ends with a specified positions. I am currently doing this with the following logic: Loop thru each ACCOUNT NUMBER Loop thru each line of the txt file and record and check if this is repeated. If repeated record the same in a hashtable. End End And I am using 'Pattern' & 'BufferedReader' java API's to perform the above task. But since it is taking a long time, I would like to know a better way of handling it. Thanks, Shibu

    Read the article

  • pl/sql creating a function with parameterized cursor with return date

    - by user3134365
    create or replace FUNCTION get_next_sch_date(cert_id VARCHAR2,test_id VARCHAR2) RETURN DATE AS CURSOR next_sch_date(pb_id number,test_no varchar2) IS SELECT Sch_Controls,PBY_FRQ,START_AFTER__CAL_DAYS,PBY_DUE_BY,PBY_NEXT_SCH_TEST_DATE FROM ms_cmp_plan_pby WHERE pby_id=pb_id AND test_plan_id=test_no; l_new_date DATE; l_new_sch number; sch_ctrl VARCHAR2(100); pb_frq VARCHAR2(100); start_days NUMBER; due_days NUMBER; test_date DATE; pb_id NUMBER; test_no NUMBER; BEGIN OPEN next_sch_date(pb_id,test_no); loop FETCH next_sch_date INTO sch_ctrl,pb_frq,start_days,due_days,test_date; SELECT DISTINCT pby_rec_id INTO l_new_sch FROM ms_cmp_assignment_log WHERE ASSIGNMENT_ID=cert_id AND PLAN_ID=test_id; exit; end loop; CLOSE next_sch_date; RETURN l_new_date; Exception WHEN others THEN RETURN NULL; end; this is my function but i dont getting excepted result

    Read the article

  • C# Timer -- measuring time slower

    - by Fassenkugel
    I'm writing a code where: I.) The user adds "events" during run-time. (To a flowlayoutpanel) These events are turning some LEDs on/off, after "x" time has elapsed and the LED-turning functions are written in a Led-function.cs class. i.e: 1) Turn left led on After 3500ms 2) Turn right led on After 4000ms II.) When the user hits start a timer starts. // Create timer. System.Timers.Timer _timer; _timer = new System.Timers.Timer(); _timer.Interval = (1); _timer.Elapsed += (sender, e) => { HandleTimerElapsed(LedObject, device, _timer); }; _timer.Start(); III.) The timer's tick event is raised every millisecond and checks if the user definied time has ellapsed. Im measuring the elapsed time with adding +1 to an integer at every tick event. (NumberOfTicks++;) //Timer Handle private void HandleTimerElapsed(Led_Functions LedObject, string device, System.Timers.Timer _timer) { NumberOfTicks++; if (NumberOfTicks >= Start_time[0]) { LedObject.LeftLED_ONnobutton(device); } } IV.) What I noticed was that when the tick was set to 1. (So the tick event is raised every millisecond) Even if I set 3000ms to the evet the LED actually flashed around 6 seconds. When the tick was set to 100. (So every 0,1s) then the flash was more accurate (3,5sec or so). Any Ideas why im having this delay in time? Or do you have any ideas how could I implement it better? Thank you!

    Read the article

< Previous Page | 313 314 315 316 317 318 319 320 321 322 323 324  | Next Page >