Search Results

Search found 9017 results on 361 pages for 'efficient storage'.

Page 325/361 | < Previous Page | 321 322 323 324 325 326 327 328 329 330 331 332  | Next Page >

  • How to alter Postgres table data based on its contents?

    - by williamjones
    This is probably a super simple question, but I'm struggling to come up with the right keywords to find it on Google. I have a Postgres table that has among its contents a column of type text named content_type. That stores what type of entry is stored in that row. There are only about 5 different types, and I decided I want to change one of them to display as something else in my application (I had been directly displaying these). It struck me that it's funny that my view is being dictated by my database model, and I decided I would convert the types being stored in my database as strings into integers, and enumerate the possible types in my application with constants that convert them into their display names. That way, if I ever got the urge to change any category names again, I could just change it with one alteration of a constant. I also have the hunch that storing integers might be somewhat more efficient than storing text in the database. First, a quick threshold question of, is this a good idea? Any feedback or anything I missed? Second, and my main question, what's the Postgres command I could enter to make an alteration like this? I'm thinking I could start by renaming the old content_type column to old_content_type and then creating a new integer column content_type. However, what command would look at a row's old_content_type and fill in the new content_type column based off of that?

    Read the article

  • Omit Properties from WebControl Serialization

    - by Laramie
    I have to serialize several objects inheriting from WebControl for database storage. These include several unecessary (to me) properties that I would prefer to omit from serialization. For example BackColor, BorderColor, etc. Here is an example of an XML serialization of one of my controls inheriting from WebControl. <Control xsi:type="SerializePanel"> <ID>grCont</ID> <Controls /> <BackColor /> <BorderColor /> <BorderWidth /> <CssClass>grActVid bwText</CssClass> <ForeColor /> <Height /> <Width /> ... </Control> I have been trying to create a common base class for my controls that inherits from WebControl and uses the "xxxSpecified" trick to selectively choose not to serialize certain properties. For example to ignore an empty BorderColor property, I'd expect [XmlIgnore] public bool BorderColorSpecified() { return !base.BorderColor.IsEmpty; } to work, but it's never called during serialization. I've also tried it in the class to be serialized as well as the base class. Since the classes themselves might change, I'd prefer not to have to create a custom serializer. Any ideas?

    Read the article

  • Delphi - Clean TListBox Items

    - by Brad
    I want to clean a list box by checking it against two other list boxes. Listbox1 would have the big list of items Listbox2 would have words I want removed from listbox1 Listbox3 would have mandatory words that have to exist for it to remain in listbox1 Below is the code I've got so far for this, it's VERY slow with large lists. // not very efficient Function checknegative ( instring : String; ListBox : TListBox ) : Boolean; Var i : Integer; Begin For I := listbox.Items.Count - 1 Downto 0 Do Begin If ExistWordInString ( instring, listbox.Items.Strings [i], [soWholeWord, soDown] ) = True Then Begin result := True; //True if in list, False if not. break; End Else Begin result := False; End; End; result:=false; End; Function ExistWordInString ( aString, aSearchString : String; aSearchOptions : TStringSearchOptions ) : Boolean; Var Size : Integer; Begin Size := Length ( aString ); If SearchBuf ( Pchar ( aString ), Size, 0, 0, aSearchString, aSearchOptions ) <> Nil Then Begin result := True; End Else Begin result := False; End; End;

    Read the article

  • merging two tables, while applying aggregates on the duplicates (max,min and sum)

    - by cloudraven
    I have a table (let's call it log) with a few millions of records. Among the fields I have Id, Count, FirstHit, LastHit. Id - The record id Count - number of times this Id has been reported FirstHit - earliest timestamp with which this Id was reported LastHit - latest timestamp with which this Id was reported This table only has one record for any given Id Everyday I get into another table (let's call it feed) with around half a million records with these fields among many others: Id Timestamp - Entry date and time. This table can have many records for the same id What I want to do is to update log in the following way. Count - log count value, plus the count() of records for that id found in feed FirstHit - the earliest of the current value in log or the minimum value in feed for that id LastHit - the latest of the current value in log or the maximum value in feed for that id. It should be noticed that many of the ids in feed are already in log. The simple thing that worked is to create a temporary table and insert into it the union of both as in Select Id, Min(Timestamp) As FirstHit, MAX(Timestamp) as LastHit, Count(*) as Count FROM feed GROUP BY Id UNION ALL Select Id, FirstHit,LastHit,Count FROM log; From that temporary table I do a select that aggregates Min(firsthit), max(lasthit) and sum(Count) Select Id, Min(FirstHit),Max(LastHit),Sum(Count) FROM @temp GROUP BY Id; and that gives me the end result. I could then delete everything from log and replace it with everything with temp, or craft an update for the common records and insert the new ones. However, I think both are highly inefficient. Is there a more efficient way of doing this. Perhaps doing the update in place in the log table?

    Read the article

  • Determining the chances of an event occurring when it hasn't occurred yet

    - by sanity
    A user visits my website at time t, and they may or may not click on a particular link I care about, if they do I record the fact that they clicked the link, and also the duration since t that they clicked it, call this d. I need an algorithm that allows me to create a class like this: class ClickProbabilityEstimate { public void reportImpression(long id); public void reportClick(long id); public double estimateClickProbability(long id); } Every impression gets a unique id, and this is used when reporting a click to indicate which impression the click belongs to. I need an algorithm that will return a probability, based on how much time has past since an impression was reported, that the impression will receive a click, based on how long previous clicks required. Clearly one would expect that this probability will decrease over time if there is still no click. If necessary, we can set an upper-bound, beyond which we consider the click probability to be 0 (eg. if its been an hour since the impression occurred, we can be pretty sure there won't be a click). The algorithm should be both space and time efficient, and hopefully make as few assumptions as possible, while being elegant. Ease of implementation would also be nice. Any ideas?

    Read the article

  • Calculate distances and sort them

    - by Emir
    Hi guys, I wrote a function that can calculate the distance between two addresses using the Google Maps API. The addresses are obtained from the database. What I want to do is calculate the distance using the function I wrote and sort the places according to the distance. Just like "Locate Store Near You" feature in online stores. I'm going to specify what I want to do with an example: So, lets say we have 10 addresses in database. And we have a variable $currentlocation. And I have a function called calcdist(), so that I can calculate the distances between 10 addresses and $currentlocation, and sort them. Here is how I do it: $query = mysql_query("SELECT name, address FROM table"); while ($write = mysql_fetch_array($query)) { $distance = array(calcdist($currentlocation, $write["address"])); sort($distance); for ($i=0; $i<1; $i++) { echo "<tr><td><strong>".$distance[$i]." kms</strong></td><td>".$write['name']."</td></tr>"; } } But this doesn't work very well. It doesn't sort the numbers. Another challenge: How can I do this in an efficient way? Imagine there are infinite numbers of addresses; how can I sort these addresses and page them?

    Read the article

  • MySQL Config File for Large System

    - by Jonathon
    We are running MySQL on a Windows 2003 Server Enterpise Edition box. MySQL is about the only program running on the box. We have approx. 8 slaves replicated to it, but my understanding is that having multiple slaves connecting to the same master does not significantly slow down performance, if at all. The master server has 16G RAM, 10 Terabyte drives in RAID 10, and four dual-core processors. From what I have seen from other sites, we have a really robust machine as our master db server. We just upgraded from a machine with only 4G RAM, but with similar hard drives, RAID, etc. It also ran Apache on it, so it was our db server and our application server. It was getting a little slow, so we split the db server onto this new machine and kept the application server on the first machine. We also distributed the application load amongst a few of our other slave servers, which also run the application. The problem is the new db server has mysqld.exe consuming 95-100% of CPU almost all the time and is really causing the app to run slowly. I know we have several queries and table structures that could be better optimized, but since they worked okay on the older, smaller server, I assume that our my.ini (MySQL config) file is not properly configured. Most of what I see on the net is for setting config files on small machines, so can anyone help me get the my.ini file correct for a large dedicated machine like ours? I just don't see how mysqld could get so bogged down! FYI: We have about 100 queries per second. We only use MyISAM tables, so skip-innodb is set in the ini file. And yes, I know it is reading the ini file correctly because I can change some settings (like the server-id and it will kill the server at startup). Here is the my.ini file: #MySQL Server Instance Configuration File # ---------------------------------------------------------------------- # Generated by the MySQL Server Instance Configuration Wizard # # # Installation Instructions # ---------------------------------------------------------------------- # # On Linux you can copy this file to /etc/my.cnf to set global options, # mysql-data-dir/my.cnf to set server-specific options # (@localstatedir@ for this installation) or to # ~/.my.cnf to set user-specific options. # # On Windows you should keep this file in the installation directory # of your server (e.g. C:\Program Files\MySQL\MySQL Server X.Y). To # make sure the server reads the config file use the startup option # "--defaults-file". # # To run run the server from the command line, execute this in a # command line shell, e.g. # mysqld --defaults-file="C:\Program Files\MySQL\MySQL Server X.Y\my.ini" # # To install the server as a Windows service manually, execute this in a # command line shell, e.g. # mysqld --install MySQLXY --defaults-file="C:\Program Files\MySQL\MySQL Server X.Y\my.ini" # # And then execute this in a command line shell to start the server, e.g. # net start MySQLXY # # # Guildlines for editing this file # ---------------------------------------------------------------------- # # In this file, you can use all long options that the program supports. # If you want to know the options a program supports, start the program # with the "--help" option. # # More detailed information about the individual options can also be # found in the manual. # # # CLIENT SECTION # ---------------------------------------------------------------------- # # The following options will be read by MySQL client applications. # Note that only client applications shipped by MySQL are guaranteed # to read this section. If you want your own MySQL client program to # honor these values, you need to specify it as an option during the # MySQL client library initialization. # [client] port=3306 [mysql] default-character-set=latin1 # SERVER SECTION # ---------------------------------------------------------------------- # # The following options will be read by the MySQL Server. Make sure that # you have installed the server correctly (see above) so it reads this # file. # [mysqld] # The TCP/IP Port the MySQL Server will listen on port=3306 #Path to installation directory. All paths are usually resolved relative to this. basedir="D:/MySQL/" #Path to the database root datadir="D:/MySQL/data" # The default character set that will be used when a new schema or table is # created and no character set is defined default-character-set=latin1 # The default storage engine that will be used when create new tables when default-storage-engine=MYISAM # Set the SQL mode to strict #sql-mode="STRICT_TRANS_TABLES,NO_AUTO_CREATE_USER,NO_ENGINE_SUBSTITUTION" # we changed this because there are a couple of queries that can get blocked otherwise sql-mode="" #performance configs skip-locking max_allowed_packet = 1M table_open_cache = 512 # The maximum amount of concurrent sessions the MySQL server will # allow. One of these connections will be reserved for a user with # SUPER privileges to allow the administrator to login even if the # connection limit has been reached. max_connections=1510 # Query cache is used to cache SELECT results and later return them # without actual executing the same query once again. Having the query # cache enabled may result in significant speed improvements, if your # have a lot of identical queries and rarely changing tables. See the # "Qcache_lowmem_prunes" status variable to check if the current value # is high enough for your load. # Note: In case your tables change very often or if your queries are # textually different every time, the query cache may result in a # slowdown instead of a performance improvement. query_cache_size=168M # The number of open tables for all threads. Increasing this value # increases the number of file descriptors that mysqld requires. # Therefore you have to make sure to set the amount of open files # allowed to at least 4096 in the variable "open-files-limit" in # section [mysqld_safe] table_cache=3020 # Maximum size for internal (in-memory) temporary tables. If a table # grows larger than this value, it is automatically converted to disk # based table This limitation is for a single table. There can be many # of them. tmp_table_size=30M # How many threads we should keep in a cache for reuse. When a client # disconnects, the client's threads are put in the cache if there aren't # more than thread_cache_size threads from before. This greatly reduces # the amount of thread creations needed if you have a lot of new # connections. (Normally this doesn't give a notable performance # improvement if you have a good thread implementation.) thread_cache_size=64 #*** MyISAM Specific options # The maximum size of the temporary file MySQL is allowed to use while # recreating the index (during REPAIR, ALTER TABLE or LOAD DATA INFILE. # If the file-size would be bigger than this, the index will be created # through the key cache (which is slower). myisam_max_sort_file_size=100G # If the temporary file used for fast index creation would be bigger # than using the key cache by the amount specified here, then prefer the # key cache method. This is mainly used to force long character keys in # large tables to use the slower key cache method to create the index. myisam_sort_buffer_size=64M # Size of the Key Buffer, used to cache index blocks for MyISAM tables. # Do not set it larger than 30% of your available memory, as some memory # is also required by the OS to cache rows. Even if you're not using # MyISAM tables, you should still set it to 8-64M as it will also be # used for internal temporary disk tables. key_buffer_size=3072M # Size of the buffer used for doing full table scans of MyISAM tables. # Allocated per thread, if a full scan is needed. read_buffer_size=2M read_rnd_buffer_size=8M # This buffer is allocated when MySQL needs to rebuild the index in # REPAIR, OPTIMZE, ALTER table statements as well as in LOAD DATA INFILE # into an empty table. It is allocated per thread so be careful with # large settings. sort_buffer_size=2M #*** INNODB Specific options *** innodb_data_home_dir="D:/MySQL InnoDB Datafiles/" # Use this option if you have a MySQL server with InnoDB support enabled # but you do not plan to use it. This will save memory and disk space # and speed up some things. skip-innodb # Additional memory pool that is used by InnoDB to store metadata # information. If InnoDB requires more memory for this purpose it will # start to allocate it from the OS. As this is fast enough on most # recent operating systems, you normally do not need to change this # value. SHOW INNODB STATUS will display the current amount used. innodb_additional_mem_pool_size=11M # If set to 1, InnoDB will flush (fsync) the transaction logs to the # disk at each commit, which offers full ACID behavior. If you are # willing to compromise this safety, and you are running small # transactions, you may set this to 0 or 2 to reduce disk I/O to the # logs. Value 0 means that the log is only written to the log file and # the log file flushed to disk approximately once per second. Value 2 # means the log is written to the log file at each commit, but the log # file is only flushed to disk approximately once per second. innodb_flush_log_at_trx_commit=1 # The size of the buffer InnoDB uses for buffering log data. As soon as # it is full, InnoDB will have to flush it to disk. As it is flushed # once per second anyway, it does not make sense to have it very large # (even with long transactions). innodb_log_buffer_size=6M # InnoDB, unlike MyISAM, uses a buffer pool to cache both indexes and # row data. The bigger you set this the less disk I/O is needed to # access data in tables. On a dedicated database server you may set this # parameter up to 80% of the machine physical memory size. Do not set it # too large, though, because competition of the physical memory may # cause paging in the operating system. Note that on 32bit systems you # might be limited to 2-3.5G of user level memory per process, so do not # set it too high. innodb_buffer_pool_size=500M # Size of each log file in a log group. You should set the combined size # of log files to about 25%-100% of your buffer pool size to avoid # unneeded buffer pool flush activity on log file overwrite. However, # note that a larger logfile size will increase the time needed for the # recovery process. innodb_log_file_size=100M # Number of threads allowed inside the InnoDB kernel. The optimal value # depends highly on the application, hardware as well as the OS # scheduler properties. A too high value may lead to thread thrashing. innodb_thread_concurrency=10 #replication settings (this is the master) log-bin=log server-id = 1 Thanks for all the help. It is greatly appreciated.

    Read the article

  • How to find every possible combination of an arbitrary number of arrays in PHP

    - by Travis
    I have an arbitrary number of nested arrays in php. For example: Array ( [0] => Array ( [0] => 36 [0] => 2 [0] => 9 ) [1] => Array ( [0] => 95 [1] => 21 [2] => 102 [3] => 38 ) [2] => Array ( [0] => 3 [1] => 5 ) ) I want to find the most efficient way to combine all possible combinations of each of these nested arrays. I'd like to end up with something that looks like this... Array ( [0] => "36,95,3" [1] => "36,95,5" [2] => "36,21,3" [3] => "36,21,5" etc... ) The order the results are combined in is not important. That is to say, there is no difference between "3,95,36", "36,95,3", and "95,36,3". I would like to omit these redundant combinations. Any suggestions on how to go about this would be much appreciated. Thanks in advance,

    Read the article

  • Can you dynamically combine multiple conditional functions into one in Python?

    - by erich
    I'm curious if it's possible to take several conditional functions and create one function that checks them all (e.g. the way a generator takes a procedure for iterating through a series and creates an iterator). The basic usage case would be when you have a large number of conditional parameters (e.g. "max_a", "min_a", "max_b", "min_b", etc.), many of which could be blank. They would all be passed to this "function creating" function, which would then return one function that checked them all. Below is an example of a naive way of doing what I'm asking: def combining_function(max_a, min_a, max_b, min_b, ...): f_array = [] if max_a is not None: f_array.append( lambda x: x.a < max_a ) if min_a is not None: f_array.append( lambda x: x.a > min_a ) ... return lambda x: all( [ f(x) for f in f_array ] ) What I'm wondering is what is the most efficient to achieve what's being done above? It seems like executing a function call for every function in f_array would create a decent amount of overhead, but perhaps I'm engaging in premature/unnecessary optimization. Regardless, I'd be interested to see if anyone else has come across usage cases like this and how they proceeded. Also, if this isn't possible in Python, is it possible in other (perhaps more functional) languages?

    Read the article

  • .Net Hash Codes no longer persistent?

    - by RobV
    I have an API where various types have custom hash codes. These hash codes are based on getting the hash of a string representation of the object in question. Various salting techniques are used so that as far as possible Hash Codes do not collide and that Objects of different types with equivalent string representations have different Hash Codes. Obviously since the Hash Codes are based on strings there are some collisions (infinite strings vs the limited range of 32 bit integers). I use hashes based on string representations since I need the hashes to persist over sessions and particularly for use in database storage of objects. Suddenly today my code has started generating different hash codes for Objects which is breaking all kinds of things. It was working earlier today and I haven't touched any of the code involved in Hash Code generation. I'm aware that the .Net documentation allows for implementation of hash codes between .Net framework versions to change (and between 32 and 64 bit versions) but I haven't changed the framework version and there has been no framework updates recently as far as I can remember Any ideas because this seems really weird? Edit Hash Codes are generated like follows: //Compute Hash Code this._hashcode = (this._nodetype + this.ToString() + PlainLiteralHashCodeSalt).GetHashCode();

    Read the article

  • Utilizing a Queue

    - by Nathan
    I'm trying to store records of transactions all together and by category for the last 1, 7, 30 or 360 days. I've tried a couple things, but they've brutally failed. I had an idea of using a queue with 360 values, one for each day, but I don't know enough about queue's to figure out how that would work. Input will be an instance of this class: class Transaction { public string TotalEarned { get; set; } public string TotalHST { get; set; } public string TotalCost { get; set; } public string Category { get; set; } } New transactions can occur at any time during the day, and there could be as many as 15 transactions in a day. My program is using a plain text file as external storage, but how I load it depends on how I decide to store this data. What would be the best way to do this?

    Read the article

  • model.matrix() with na.action=NULL?

    - by Vincent
    I have a formula and a data frame, and I want to extract the model.matrix(). However, I need the resulting matrix to include the NAs that were found in the original dataset. If I were to use model.frame() to do this, I would simply pass it na.action=NULL. However, the output I need is of the model.matrix() format. Specifically, I need only the right-hand side variables, I need the output to be a matrix (not a data frame), and I need factors to be converted to a series of dummy variables. I'm sure I could hack something together using loops or something, but I was wondering if anyone could suggest a cleaner and more efficient workaround. Thanks a lot for your time! And here's an example: dat <- data.frame(matrix(rnorm(20),5,4), gl(5,2)) dat[3,5] <- NA names(dat) <- c(letters[1:4], 'fact') ff <- a ~ b + fact # This omits the row with a missing observation on the factor model.matrix(ff, dat) # This keeps the NA, but it gives me a data frame and does not dichotomize the factor model.frame(ff, dat, na.action=NULL) Here is what I would like to obtain: (Intercept) b fact2 fact3 fact4 fact5 1 1 0.7266086 0 0 0 0 2 1 -0.6088697 0 0 0 0 3 NA 0.4643360 NA NA NA NA 4 1 -1.1666248 1 0 0 0 5 1 -0.7577394 0 1 0 0 6 1 0.7266086 0 1 0 0 7 1 -0.6088697 0 0 1 0 8 1 0.4643360 0 0 1 0 9 1 -1.1666248 0 0 0 1 10 1 -0.7577394 0 0 0 1

    Read the article

  • Can I split a single SQL 2008 DB Table into multiple filegroups, based on a discriminator column?

    - by Pure.Krome
    Hi folks, I've got a SQL Server 2008 R2 database which has a number of tables. Two of these tables contains a lot of large data .. mainly because one of them is VARBINARY(MAX) and the sister table is GEOGRAPHY. (Why two tables? Read Below if you're interested***) The data in these tables are geospatial shapes, such as zipcode boundaries. Now, the first 70K odd rows are for DataType = 1 the rest 5mil rows are for DataType = 2 Now, is it possible to split the table data into two files? so all rows that are for DataType != 2 goes into File_A and DataType = 2 goes into File_B? This way, when I backup the DB, I can skip adding File_B so my download is waaaaay smaller? Is this possible? I guessing you might be thinking - why not keep them as TWO extra tables? Mainly because in the code, the data is conceptually the same .. it's just happens that I want to split the storage of this model data. It really messes up my model if I now how two aggregates in my model, instead of one. ***Entity Framework doesn't like Tables with GEOGRAPHY, so i have to create a new table which transforms the GEOGRAPHY to VARBINARY, and then drop that into EF.

    Read the article

  • My program is spending most of its time in objc_msgSend. Does that mean that Objective-C has bad per

    - by Paperflyer
    Hello Stackoverflow. I have written an application that has a number of custom views and generally draws a lot of lines and bitmaps. Since performance is somewhat critical for the application, I spent a good amount of time optimizing draw performance. Now, activity monitor tells me that my application is usually using about 12% CPU and Instrument (the profiler) says that a whopping 10% CPU is spent in objc_msgSend (mostly in drawing related system calls). On the one hand, I am glad about this since it means that my drawing is about as fast as it gets and my optimizations where a huge success. On the other hand, it seems to imply that the only thing that is still using my CPU is the Objective-C overhead for messages (objc_msgSend). Hence, that if I had written the application in, say, Carbon, its performance would be drastically better. Now I am tempted to conclude that Objective-C is a language with bad performance, even though Cocoa seems to be awfully efficient since it can apparently draw faster than Objective-C can send messages. So, is Objective-C really a language with bad performance? What do you think about that?

    Read the article

  • Matching on search attributes selected by customer on front end

    - by CodeNinja1974
    I have a method in a class that allows me to return results based on a certain set of Customer specified criteria. The method matches what the Customer specifies on the front end with each item in a collection that comes from the database. In cases where the customer does not specify any of the attributes, the ID of the attibute is passed into the method being equal to 0 (The database has an identity on all tables that is seeded at 1 and is incremental). In this case that attribute should be ignored, for example if the Customer does not specify the Location then customerSearchCriteria.LocationID = 0 coming into the method. The matching would then match on the other attributes and return all Locations matching the other attibutes, example below: public IEnumerable<Pet> FindPetsMatchingCustomerCriteria(CustomerPetSearchCriteria customerSearchCriteria) { if(customerSearchCriteria.LocationID == 0) { return repository.GetAllPetsLinkedCriteria() .Where(x => x.TypeID == customerSearchCriteria.TypeID && x.FeedingMethodID == customerSearchCriteria.FeedingMethodID && x.FlyAblityID == customerSearchCriteria.FlyAblityID ) .Select(y => y.Pet); } } The code for when all criteria is specified is shown below: private PetsRepository repository = new PetsRepository(); public IEnumerable<Pet> FindPetsMatchingCustomerCriteria(CustomerPetSearchCriteria customerSearchCriteria) { return repository.GetAllPetsLinkedCriteria() .Where(x => x.TypeID == customerSearchCriteria.TypeID && x.FeedingMethodID == customerSearchCriteria.FeedingMethodID && x.FlyAblityID == customerSearchCriteria.FlyAblityID && x.LocationID == customerSearchCriteria.LocationID ) .Select(y => y.Pet); } I want to avoid having a whole set of if and else statements to cater for each time the Customer does not explicitly select an attribute of the results they are looking for. What is the most succint and efficient way in which I could achieve this?

    Read the article

  • SELECT set of most recent id, amount FROM table, where id occurs many times

    - by Jon Cram
    I have a table recording the amount of data transferred by a given service on a given date. One record is entered daily for a given service. I'd like to be able to retrieve the most recent amount for a set of services. Example data set: serviceId | amount | date ------------------------------- 1 | 8 | 2010-04-12 2 | 11 | 2010-04-12 2 | 14 | 2010-04-11 3 | 9 | 2010-04-11 1 | 6 | 2010-04-10 2 | 5 | 2010-04-10 3 | 22 | 2010-04-10 4 | 17 | 2010-04-19 Desired response (service ids 1,2,3): serviceId | amount | date ------------------------------- 1 | 8 | 2010-04-12 2 | 11 | 2010-04-12 3 | 9 | 2010-04-11 Desired response (service ids 2, 4): serviceId | amount | date ------------------------------- 2 | 11 | 2010-04-12 4 | 17 | 2010-04-19 This retrieves the equivalent as running the following once per serviceId: SELECT serviceId, amount, date FROM table WHERE serviceId = <given serviceId> ORDER BY date DESC LIMIT 0,1 I understand how I can retrieve the data I want in X queries. I'm interested to see how I can retrieve the same data using either a single query or at the very least less than X queries. I'm very interested to see what might be the most efficient approach. The table currently contains 28809 records. I appreciate that there are other questions that cover selecting the most recent set of records. I have examined three such questions but have been unable to apply the solutions to my problem.

    Read the article

  • Slideshow in Javascript without framework, animation?

    - by aaron
    The issue I am having is fairly complicated to explain. I have written up a javascript that displays an image slideshow, and it works fairly well, despite using up more resources than I would like // imgArr[] is populated before var i = 0; var pageLoaded = 0; window.onload = function() {pageLoaded = 1;} function loaded(i,f) { if (document.getElementById(i) != null) f(); else if (!pageLoaded) setTimeout('loaded(\''+i+'\','+f+')',100); } } function displaySlideshow() { document.getElementById(destinationId).innerHTML = '<div id="slideWindow"><img src="'+imgArr[i]+'" />' + '<img src="'+imgArr[i + 1]+'" /></div>'; setTimeout('displaySlideshow()',1000*3); i++; if (i >= imgArr.length - 1) i = 0; } loaded(destinationId,displaySlideshow); So, this script dynamically adds two images to a HTML element, and it is wrapped in a div. The div is styled with the height and width of the image, with the overflow (the second image) hidden. The second image is below the first, and the slideshow is meant to go from RIGHT to LEFT. My inquiry is twofold: 1) Is there a more efficient way of doing this? 2) How would I animate the images? Would I need to put the second image on the right of the first with CSS somehow, and then set a timer to pull the images (via a style) leftward?

    Read the article

  • SQL Database Schema Design For Large 3 Billion Relationship Database.

    - by K-Bell
    Get your geek on. Can you solve this? I am designing a products database for SQL Server 2008 R2 Ed. (not Enterprise Ed.) that will be used to store custom product configurations for over 30,000 distinct products. The database will have up to 500 users at a time. Here is the design problem… Each Product has a collection of Parts (up to 50 parts per product). So if I have 30,000 Products and each of them can have up to 50 Parts, that’s 1.5 million distinct Product-to-Part relationships …or as an equation… 30,000 (Products) X 50 (Parts) = 1.5 million Product-to-Parts records. …and If… Each Part can have up to 2000 finish options (A finish is a paint color). NOTE: Only one finish will be selected by a user at run-time. The 2000 finish options I need to store are the allowed options for a specific part on a specific product. So if I have 1.5 million distinct product-to-part relationships/records and each of those parts can have up to 2,000 finishes that is 3 billion allowable product-to-part-to finish relationships/records …or as an equation… 1.5 million (Parts) x 2,000 (Finishes) = 3 Billion Product-to-Part-to-Finishes records. How can I design this database so that I can execute fast and efficient queries for a specific product and return its list of Parts and all the allowable Finishes for each part without 3 Billion Product-to-Part-to-Finish records? Read time is more important then write time. Please post your thoughts/suggestions if you have experience with large databases. Thanks!

    Read the article

  • Performance issue finding weekdays over a given period

    - by Oysio
    I have some methods that return the number of weekdays between two given dates. Since calling these methods become very expensive to call when the two dates lie years apart, I'm wondering how these methods could be refactored in a more efficient way. The returned result is correct but I feel that the iphone processor is struggling to keep up and consequently freezes up the application when I would call these methods over a period of say 10years. Any suggestions ? //daysList contains all weekdays that need to be found between the two dates -(NSInteger) numberOfWeekdaysFromDaysList:(NSMutableArray*) daysList startingFromDate:(NSDate*)startDate toDate:(NSDate*)endDate { NSInteger retNumdays = 0; for (Day *dayObject in [daysList objectEnumerator]) { if ([dayObject isChecked]) { retNumdays += [self numberOfWeekday:[dayObject weekdayNr] startingFromDate:startDate toDate:endDate]; } } return retNumdays; } -(NSInteger) numberOfWeekday:(NSInteger)day startingFromDate:(NSDate*)startDate toDate:(NSDate*)endDate { NSInteger numWeekdays = 0; NSDate *nextDate = startDate; NSComparisonResult result = [endDate compare:nextDate]; //Do while nextDate is in the past while (result == NSOrderedDescending || result == NSOrderedSame) { if ([NSDate weekdayFromDate:nextDate] == day) { numWeekdays++; } nextDate = [nextDate dateByAddingDays:1]; result = [endDate compare:nextDate]; } return numWeekdays; }

    Read the article

  • Simplifying loop in Objective-C

    - by Joe Habadas
    I have this enormous loop in my code (not by choice), because I can't seem to make it work any other way. If there's some way make this simple as opposed to me repeating it +20 times that would be great, thanks. for (NSUInteger i = 0; i < 20; i++) { if (a[0] == 0xFF || b[i] == a[0]) { c[0] = b[i]; if (d[0] == 0xFF) { d[0] = c[0]; } ... below repeats +18 more times with [i+2,3,4,etc] ... if (a[1] == 0xFF || b[i + 1] == a[1]) { c[1] = b[i + 1]; if (d[1] == 0xFF) { d[1] = c[1]; } ... when it reaches the last one it calls a method ... [self doSomething]; continue; i += 19; ... then } repeats +19 times (to close things)... } } } I've tried almost every possible combo of things that I know of attempting to make this smaller and efficient. Take a look at my flow chart — pretty huh? i'm not a madman, honest.

    Read the article

  • How to render all records from a nested set into a real html tree

    - by Christoph Schiessl
    I'm using the awesome_nested_set plugin in my Rails project. I have two models that look like this (simplified): class Customer < ActiveRecord::Base has_many :categories end class Category < ActiveRecord::Base belongs_to :customer # Columns in the categories table: lft, rgt and parent_id acts_as_nested_set :scope => :customer_id validates_presence_of :name # Further validations... end The tree in the database is constructed as expected. All the values of parent_id, lft and rgt are correct. The tree has multiple root nodes (which is of course allowed in awesome_nested_set). Now, I want to render all categories of a given customer in a correctly sorted tree like structure: for example nested <ul> tags. This wouldn't be too difficult but I need it to be efficient (the less sql queries the better). Update: Figured out that it is possible to calculate the number of children for any given Node in the tree without further SQL queries: number_of_children = (node.rgt - node.lft - 1)/2. This doesn't solve the problem but it may prove to be helpful.

    Read the article

  • Passing C++ object to C++ code through Python?

    - by cornail
    Hi all, I have written some physics simulation code in C++ and parsing the input text files is a bottleneck of it. As one of the input parameters, the user has to specify a math function which will be evaluated many times at run-time. The C++ code has some pre-defined function classes for this (they are actually quite complex on the math side) and some limited parsing capability but I am not satisfied with this construction at all. What I need is that both the algorithm and the function evaluation remain speedy, so it is advantageous to keep them both as compiled code (and preferrably, the math functions as C++ function objects). However I thought of glueing the whole simulation together with Python: the user could specify the input parameters in a Python script, while also implementing storage, visualization of the results (matplotlib) and GUI, too, in Python. I know that most of the time, exposing C++ classes can be done, e.g. with SWIG but I still have a question concerning the parsing of the user defined math function in Python: Is it possible to somehow to construct a C++ function object in Python and pass it to the C++ algorithm? E.g. when I call f = WrappedCPPGaussianFunctionClass(sigma=0.5) WrappedCPPAlgorithm(f) in Python, it would return a pointer to a C++ object which would then be passed to a C++ routine requiring such a pointer, or something similar... (don't ask me about memory management in this case, though :S) The point is that no callback should be made to Python code in the algorithm. Later I would like to extend this example to also do some simple expression parsing on the Python side, such as sum or product of functions, and return some compound, parse-tree like C++ object but let's stay at the basics for now. Sorry for the long post and thx for the suggestions in advance.

    Read the article

  • "date_part('epoch', now() at time zone 'UTC')" not the same time as "now() at time zone 'UTC'" in po

    - by sirlark
    I'm writing a web based front end to a database (PHP/Postgresql) in which I need to store various dates/times. The times are meant to be always be entered on the client side in the local time, and displayed in the local time too. For storage purposes, I store all dates/times as integers (UNIX timestamps) and normalised to UTC. One particular field has a restriction that the timestamp filled in is not allowed to be in the future, so I tried this with a database constraint... CONSTRAINT not_future CHECK (timestamp-300 <= date_part('epoch', now() at time zone 'UTC')) The -300 is to give 5 minutes leeway in case of slightly desynchronised times between browser and server. The problem is, this constraint always fails when submitting the current time. I've done testing, and found the following. In PostgreSQL client: SELECT now() -- returns correct local time SELECT date_part('epoch', now()) -- returns a unix timestamp at UTC (tested by feeding the value into the date function in PHP correcting for its compensation to my time zone) SELECT date_part('epoch', now() at time zone 'UTC') -- returns a unix timestamp at two time zone offsets west, e.g. I am at GMT+2, I get a GMT-2 timestamp. I've figured out obviously that dropping the "at time zone 'UTC'" will solve my problem, but my question is if 'epoch' is meant to return a unix timestamp which AFAIK is always meant to be in UTC, why would the 'epoch' of a time already in UTC be corrected? Is this a bug, or I am I missing something about the defined/normal behaviour here.

    Read the article

  • What's a good way to do testing a plug-in on multiple Windows and Outlook versions?

    - by Andrei
    Hello, We're building a plug-in for Outlook that should work on multiple Windows versions (XP, Vista, 7) and also with different Outlook versions (2003, 2007, 2010). The testing problem I am facing right now, is that I can't figure out a good/convenient/thorough way to test the application on multiple Windows and Outlook versions. At the moment, I have a VirtualBox which runs many virtual machines, with different Windows versions and Outlook versions. So I would have a virtual machine with Windows 7 testing Outlook 2010, and another one with Windows 7 testing Outlook 2007, Windows Vista with Outlook 2010 and so on, going through some of the possible combinations. It kind of gets the job done, although it is cumbersome and takes a long time to test. Some of the testing included in the application is unit testing, but this is also rather tied in with the machine I test it on (windows 7 with outlook 2010). For example, I was using ManagementObject recently, which worked fine on my system (and thus passed the unit test for that method), however, using that object threw an exception in another person's system, which crashed the application. I work on Visual Studio 2010 Ultimate. The questions: Is there a more elegant way to make the testing process more streamline and more efficient? Any other testing methods you recommend? How would you deal with this problem? Thanks! Looking forward to your replies.

    Read the article

  • How to effectively execute this cron job?

    - by Lost_in_code
    I have a table with 200 rows. I'm running a cron job every 10 minutes to perform some kind of insert/update operation on the table. The operation needs to be performed only on 5 rows at a time every time the cron job runs. So in first 10 mins records 1-5 are updated, records 5-10 in the 20th minute and so on. When the cron job runs for the 20th time, all the records in the table would have been updated exactly once. This is what is to be achieved at least. And the next cron job should repeat the process again. The problem: is that, every time a cron job runs, the insert/update operation should be performed on N rows (not just 5 rows). So, if N is 100, all records would've been updated by just 2 cron jobs. And the next cron job would repeat the process again. Here's an example: This is the table I currently have (200 records). Every time a cron job executes, it needs to pick N records (which I set as a variable in PHP) and update the time_md5 field with the current time's MD5 value. +---------+-------------------------------------+ | id | time_md5 | +---------+-------------------------------------+ | 10 | 971324428e62dd6832a2778582559977 | | 72 | 1bd58291594543a8cc239d99843a846c | | 3 | 9300278bc5f114a290f6ed917ee93736 | | 40 | 915bf1c5a1f13404add6612ec452e644 | | 599 | 799671e31d5350ff405c8016a38c74eb | | 56 | 56302bb119f1d03db3c9093caf98c735 | | 798 | 47889aa559636b5512436776afd6ba56 | | 8 | 85fdc72d3b51f0b8b356eceac710df14 | | .. | ....... | | .. | ....... | | .. | ....... | | .. | ....... | | 340 | 9217eab5adcc47b365b2e00bbdcc011a | <-- 200th record +---------+-------------------------------------+ So, the first record(id 10) should not be updated more than once, till all 200 records are updated once - the process should start over once all the records are updated once. I have some idea on how this could be achieved, but I'm sure there are more efficient ways of doing it. Any suggestions?

    Read the article

< Previous Page | 321 322 323 324 325 326 327 328 329 330 331 332  | Next Page >