Search Results

Search found 10536 results on 422 pages for 'cpu usage'.

Page 331/422 | < Previous Page | 327 328 329 330 331 332 333 334 335 336 337 338  | Next Page >

  • What steps should I take to debug this non-starting hvm virtual machine?

    - by Ophidian
    I have a dom0 machine running CentOS 5.4 with all the latest updates using Xen as my hypervisor. I am using Xen in part because this machine was set up prior to KVM being included in RHEL, and in part because KVM's network bridging configuration is not nearly as simple as Xen's. The dom0 machine is headless and I do all of my VM management via virsh from the command line. I have two hvm domU's: A web server running CentOS 5.4 A mail server running Gentoo Both VM's are backed by LV's on the dom0 but do not use LVM in the domU. Both have virtually identical libvirt configurations (differing by expected things like name, UUID, NIC MAC, VNC port, etc). The web server domU (WSdomU hereafter) does not start since applying the most recent kernel update (kernel-xen-2.6.18-164.15.1.el5.x86_64 and kernel-2.6.18-164.15.1.el5.x86_64 for the dom0 and WSdomU respectively). By 'not start' I mean it appears to be running but it does not use an CPU cycles, does not bring up a graphical console, and does not respond on the network. The WSdomU is listed as no state rather than the normal running or blocked in xentop. The mail server domU starts fine and functions normally. Here are the steps I have taken so far that did not solve the problem: Reboot the dom0 to see if things come up on their own Check xen dmesg on dom0 Check xend logs (a cursory viewing did not show anything blatant; specific suggestions of things to look for would be appreciated) Attempted to connect to the WSdomU's graphical (VNC) console from the dom0 Shutdown the mail server domU and attempt to start the WSdomU Check the SELinux labels on backing LV's (they're the same) Set SELinux to permissive and attempt to start the WSdomU Use virsh edit to try tweaking the WSdomU config virsh undefine, reboot, virsh define the WSdomU config dd the WSdomU LV to an .img file, copy it to my Fedora desktop and run it under KVM (works fine) What steps should I take next to debug this? I will edit in any additional configuration's requested in the comments.

    Read the article

  • Laptop shuts down randomly without warning

    - by Robert P.
    My Asus Zenbook UX32V turns off randomly when I'm working on it. This happens both when the computer is recently turned on (5 minutes), and after being on for several days. I'm not running any heavy software The laptop is not heating The fan is not working on the maximum capacity (it's not heating) It happens when the laptop is lying still on the table It is no warning, it simply goes black It happens both when charging and on battery My guess is that it suddenly lose power somehow. What puzzles me is that I can flip the laptop upside down, sideways, shake it, etc. without it shutting off. This makes me think it's not something that's loose causing occasional short-circuits. I realize that the laptop probably doesn't like flipping and shaking, but it was the best way I could troubleshoot. I rarely turn the computer off, only have it in hibernate or sleep mode (most often hibernate). I've never experienced that the laptop is off when I wake it up from sleep mode. I've had the problem for a few months and it happens 2-8 times a week. Specs: Asus Zenbook UX32V Windows 8.1 (it happened in Windows 8.0 too) Intel i5-3317U CPU @ 1.70GHz The laptop is approx 1.5 years, but it has a small dent on one of the sides that probably voids the warranty. The dent has been there since week one and I don't think it's related to the problems I'm having now. Does anyone have a clue what might cause this, and how it might be fixed? I've read all other questions (some of which are listed below) that seem related to my issue, but none report the same behavior as I'm experiencing. Most report heavy games, heating etc. Asus N53J Laptop randomly shuts down Laptop is randomly shutting off Computer shuts down without warning My laptop acer aspire 5720 suddenly turn off randomly Computer randomly shutting down Windows 8.1 randomly shuts self down ASUS K55VM Laptop unexpectedly shuts down

    Read the article

  • postfix smtp_fallback_relay for deferred messages to a single domain

    - by EdwardTeach
    I use Postfix to send messages to a mail server outside my organization which frequently rejects/defers my mail. My Postfix server sees that these messages are deferred and tries again, eventually getting through. Final delivery can take up to an hour, which makes my users unhappy. In comparison, mail from my Postfix server to other hosts works normally. I have now found out about a second, unofficial MX for this domain that does not reject/defer mail. This second MX does not appear when doing a DNS MX query for the domain. Therefore, for the problem domain I would like to use this second MX as a fallback. That is: whenever mail is deferred by the primary MX, try again on the unofficial second MX. I see that there is already a postfix configuration "smtp_fallback_relay". However the documentation seems to indicate that I can not restrict usage of the fallback to a single domain. The documentation also doesn't mention deferred message handling. So is there a way to configure a single-domain, deferred-retry fallback host in Postfix? For reference, I am including my postconf output (the host names and ip addresses are fake): alias_database = hash:/etc/aliases alias_maps = hash:/etc/aliases, hash:/etc/postfix/legacy_mailman, ldap:/etc/postfix/ldap-aliases.cf append_dot_mydomain = no biff = no config_directory = /etc/postfix default_destination_concurrency_limit = 2 inet_interfaces = all inet_protocols = all local_destination_concurrency_limit = 2 local_recipient_maps = $alias_maps mailbox_size_limit = 0 mydestination = myhost.my.network, localhost.my.network, localhost, my.network myhostname = myhost.my.network mynetworks = 127.0.0.0/8, [::ffff:127.0.0.0]/104, [::1]/128, 10.10.10.0/24 myorigin = my.network readme_directory = no recipient_delimiter = + relay_domains = $mydestination relayhost = smtp_fallback_relay = the.problem.host smtp_header_checks = smtpd_banner = $myhostname ESMTP $mail_name virtual_alias_maps = hash:/etc/postfix/virtual

    Read the article

  • Substiting a line through PHP in SSH

    - by Asad Moeen
    I've already setup SSH usage in PHP and most of the things work. Now what I want to do is that I'm looking to edit a line in a file and replace it back. It works directly on the server but can't seem to get it working with PHP files. Here is what I'm trying. $new_line1 = 'Line $I want to add - The $I has to go into the file as it is'; $new_line2 = 'Ending $text of the line - $text again goes into file; $query = "Addition to line"; $exec1= 'cd /root; perl -pe "s/.*/' ; $exec2= '/ if $. == 37" Edit.sh > Edited.sh'; $new="$exec1$new_line1$query$new_line2$exec2"; $edit="cd /root/mp; cp Edited.sh Edit.sh"; echo $ssh->exec($new); echo $ssh->exec($edit); Now the thing is that running the perl command directly in SSH works without any errors but when I run this through PHP I get the error: Substitution replacement not terminated at -e line 1. I want to know why would it work this way and not that?

    Read the article

  • Removing resource limits on Solaris 10

    - by mikeydonkey
    How should one remove all potential artificial resource limitations for a process? I just saw a case where a server application consumed resources so that some limitation was hit. The other shells into the same server etc were all extremely slow (waiting for something to free up for them; ie. prstat starting 5 minutes). It wasn't CPU/memory related problem so I think it has got something to do with ulimits / projects. Already managed to set the maximum open files to 500 000 and it helped a little bit. However there is something else and I can not figure out what resource is maxed out. I can get some in-house administrator probably to check this but I would like to understand how I could make sure there shouldn't be any limitations! If you think I am going the wrong way (would be better to figure out what limitation should be specfically tuned etc) please feel free to point me to the correct way. I know technical stuff - it's just Solaris 10 that is giving me headache :/

    Read the article

  • Windows 7 restarts while being idle

    - by Ondrej Slinták
    My Windows 7 almost always restarts when I keep it idle for ~20-30mins. It happened randomly before, but lately, if I leave the computer I can be sure it's gonna restart after those 30mins. It never happens when I play games or work tho, just when it's idle. It's a fresh install of Windows 7 64bit. I had also problems while installing it, it always crashed while finalizing the install and I had to reinstall again. Eventually it installed on 3rd or 4th try after I deleted all of my partitions and added them again. I thought it might have been a hardware problem, but temperatures seem to be okay and I have no idea how to track what might have been causing it. Any ideas? I'm running Windows 7 64bit on: Gigabyte EX58-UD4P Intel(R) Core(TM) i7 CPU 920 @ 2.67GHz NVIDIA GeForce GTX 260 6GB of DDR3 1066Mhz RAM WDC WD1001FALS-00J7B0 1TB SATA II I have a very bad feeling it might be something with HDD and its compatibility with Windows 7 as I haven't had those problems for 1 year while I had Vista. Edit: I checked Event Viewer critical errors from this night. PC restarted first time at 11:12pm, then at 3:06am and since then every ~20min until I came back to it. Error message is: The system has rebooted without cleanly shutting down first. This error could be caused if the system stopped responding, crashed, or lost power unexpectedly. Source: Kernel-Power

    Read the article

  • Membership in two domains

    - by imagodei
    Hello! I would your suggestions for an effective solution for a person, who needs to access resources in two Windows domains and wants to use one computer. It's about our CEO, who has accepted a second position in another company. Accessing files and folders isn't big problem. The greatest challenge I see is that he wants to conveniently access Exchange accounts in both companies; he would like to send and receive mail in single Outlook if possible (two profiles?) There is also a challenge with calendars: he would like to have one calendar for all activities from both Exchange accounts. Creating a POP3 account for accessing second Exchange server is a last resort, because obviously there is a problem with scheduling meetings and other calendar related tasks. Forwarding and receiving all mail/tasks on primary Exchange server is inconvenient because simple replying to original sender is disabled; and also when manually changing the recepient, he will receive mail from the wrong address. We were considering Virtualisation, that is setting up an instance of virtual machine inside existing installation and then joining this virtual computer to a second domain. Then installing another MS Outlook. This would of course mean two different Outlook accounts, two different calendars, but would at least enable our CEO to access all information from a single laptop. Does anyone have any other idea? I know setting up two domains on a single computer is a no-go (without much hacking at least), but effective workarounds are appreciate. The thing I am looking here is high usage/efficiency/productivity, but also as elegant solution from the administration point of view. Thank you very much (if you managed to read this through, this is a good sign ^_^ )

    Read the article

  • Is there a way to exclude a specific drive vdi from "snapshots" in VirtualBox?

    - by Graza
    ...or is there another space-efficient way of dealing with the page/swap file of the Guest O/S? I've realised that its quite possible/likely that one of the things which "bloats" the snapshot/diff vdi's when a snapshot is taken is the guest operating system's pagefile. For example, say I have a 2Gb swap-file in a Windows guest OS, and over the course of a few weeks the usage of the swap file has gone over 1Gb a couple of times. When I next create a snapshot, it seems likely that I'd be almost guaranteed around 1Gb of space taken up in the new differencing disk just because of changes in the swap file. Obviously (provided I never did "live" snapshots on running or paused machines, and only ever did them when the machine was shut down), I would not need any of the information in the swap file to be saved. So this would simply be a waste of 1Gb. I'm wondering if there's a way to attach a vdi to a VM and flag it as "exclude from snapshots" - which would mean I could put the swap file on a different vdi which would never be included in a snapshot. Or if anyone has any other suggestions. Or an explanation about why it might not be an issue. I could obviously delete and recreate a swap drive vdi every time I did a snapshot to achieve the same effect, but this is a little more effort than simply clicking "create snapshot"....

    Read the article

  • When machine is turned on, only the fan runs

    - by Gopal
    Hi, I have an issue slightly similar to this one posted here, http://superuser.com/questions/127016/troubleshooting-monitor-never-turns-on-system-fans-running-dvd-rom-does-not-op My configuration is as follows: EPOX 9NPA+ Ultra motherboard AMD Athlon 64 CPU Corsair 2 x 1GB PC3200 DDR RAM 1 DVD RW drive and 1 CD ROM Drive SATA 250 GB Hard drive 400W Power supply EVGA 256MB graphics card I have had this configuration for about four years. Last month, I started having issues in starting the machine. It wouldn't start when I press the ON button in the front of the case. So I used to pull out the power cord and plug it back in and then switch on in the front, and it used to work fine. And then one fine day, when I plugged in the power cord at the back, even without switching on the power-on button at the front, I saw that the fan at the back was running. So I opened the system. Then I could see that all the fans inside were running. I replaced the power supply. No luck there. Then I replaced the CMOS battery. Again nothing improved. Even when I removed all the cards and memory, I still get one short beep. That's it. Any idea how to proceed on this? Anything else could be checked? I want to confirm if this is a motherboard failure, before proceeding to replace it.

    Read the article

  • split virtualization design based on environment or server role?

    - by Dan
    I'm setting up the server environment for a new software development group, which will include 4 test environments. These are web applications, so each environment will have an application server and a database server. I'm planning on buying two physical servers (e.g. 6-core CPU each with 12GB or so of RAM), and I'm thinking virtualization is appropriate here. With that in mind, I've thought of a couple ways that I could organize the virtualization strategy: - Separated by server role: Server 1 has all the application servers, each in their own guest VM. Server 2 has all the databases. OR - Separated by environment: Server 1 has a VM for two of the environments, with the VM containing both the app server and the database server. Server 2 would also contain two test environments, with the same style (app server and database in same VM). The advantages I see with all the app servers on one server and all the databases on another server is that I could probably be more efficient with the database server (one instance running multiple databases). But the other option seems easier to manage (archives/restorations would be contained in a single VM). Any recommendations? TIA.

    Read the article

  • Which upgrade path for disk IO bound postgres server?

    - by user41679
    Hi all, We currently have a Sun x4270 with 2xquad core Xeon Nehalmen 2.93ghz cores (16 threads), 72 gig of ram and 16 x 10k SAS disks split between the os raid 1, a partition for the Write Ahead Logs which is raid 10 and a partition for the database tables and indexes which is also raid 10, all xfs. I'm currently evaluating which path to go down in terms of upgrades. We'll be sharding the DB at some point soon, but for now I need to focus on hardware upgrades specifically. The machine is not CPU or memory bound at all at the moment, just IOWait is become an issue. The machine is mostly write access as we have a heavy caching layer. We're seeing about 300 write IOPS average on both the database partitions. We don't have any additional storage infrastructure like a Fiber Channel or ISCSI network. Budget isn't too much of a concern, something inline with the size of this server (i.e no $1m IBM machines) Space is ok on the DB side of things, we're running out obviously but there's also some reduction we can do. Additional space would be good though. My current thoughts are either: * ISCSI SAN, possible with 10Gbit network that has solid state acceleration. * FusionIO card / Sun F20 card (will the FusionIO card work in the Sun box? * DAS shelf (something like this http://www.broadberry.co.uk/das-direct-attached-storage-servers/cyberstore-224s-das) which a combination of 15k sas disks and some Intel X25-E drives for DB indexes etc) what would I need to put in the x4270 to add a DAS shelf? I think it's a SAS HBA card, do I have to use Sun's own card or will any PCI Express card work? Anything else??? what would you guys do from your experience? I appreciate it's a lot of questions, but I haven't expanded a DB machine for a number of years and the landscape has changed dramatically since then! Any advice or feedback would be very much appreciated. Let me know if there's anything else I can clarify. Thanks in advance!

    Read the article

  • Why do hosts prefer Linux to Windows Server?

    - by iconiK
    So far I see a HUGE majority of hosts provide only Linux shared hosting, providing Windows only to VPS (or even to only dedicated servers). Why is it so? While Windows is a lot more expensive than Linux (though it depends on a lot of factors, not just initial and support license cost), it also provides ASP.NET, IIS and of course, Microsoft SQL Server. I know in the past it might have been because of cPanel being Linux only but now they have a Windows version. But still, why is Linux predominantly used on shared hosting? PHP works on both systems. IIS can be (and probably is) faster. MySQL runs on both systems as well. cPanel has a Windows version. Python, Perl, Ruby, all run on Windows as well. You even have MS SQL Server Express, which I find more superior than MySQL in both speed and features. Access is there for low usage requirements, as is SQLite (which is so great for quick small stuff). And with PowerShell you have a good alternative to the Unix shell. EDIT: I am looking for common reasons, I realize each hosting company (and/or it's clients) may have different needs. This becomes very important when you get to VPS or Cloud which give you a full operating system to use.

    Read the article

  • MySQL partition "full"?

    - by gdea73
    I have a server that runs Debian 6.2, with Apache, PHP5, and MySQL. Well, I hadn't done anything with MySQL at all so far, just Apache and PHP; I must have installed it (mysql-server) at some point along the line, and I decided to login to the database for the first time a couple days ago as I was considering using the database for a future website project. I noticed that the "root" user had a password, and I didn't recall having set one. My usual root password was incorrect. So I attempted to reset the password. sudo service mysql stop (stopped successfully) sudo /usr/bin/mysqld_safe --skip-grant-tables --skip-networking & started successfully, from what I can tell. However, mysql itself returns "Can't connect to local MySQL server through socket '/var/run/mysqld/mysqld,sock' (2)", and additionally sudo service mysql start returns "/etc/init.d/mysql: ERROR: The partition with /var/lib/mysql is too full! ... failed!" df -h tells me that / is 26% used, a 20GB partition, and /home, roughly 900GB, has only 5% usage. On a potentially related note, I've been experiencing random hangs since I noticed this problem, my tty2 randomly froze several times while idle, and the entire system is suddenly unstable. gnome-terminal also does not open. (Gnome-terminal apparently works now, disregard that part, but the server is still being somewhat unstable, I randomly lost connection when I was SSHed into it from my laptop, twice now.)

    Read the article

  • Does btrfs balance also defragment files?

    - by pauldoo
    When I run btrfs filesystem balance, does this implicitly defragment files? I could imagine that balance simply reallocates each file extent separately, preserving the existing fragmentation. There is an FAQ entry, 'What does "balance" do?', which is unclear on this point: btrfs filesystem balance is an operation which simply takes all of the data and metadata on the filesystem, and re-writes it in a different place on the disks, passing it through the allocator algorithm on the way. It was originally designed for multi-device filesystems, to spread data more evenly across the devices (i.e. to "balance" their usage). This is particularly useful when adding new devices to a nearly-full filesystem. Due to the way that balance works, it also has some useful side-effects: If there is a lot of allocated but unused data or metadata chunks, a balance may reclaim some of that allocated space. This is the main reason for running a balance on a single-device filesystem. On a filesystem with damaged replication (e.g. a RAID-1 FS with a dead and removed disk), it will force the FS to rebuild the missing copy of the data on one of the currently active devices, restoring the RAID-1 capability of the filesystem.

    Read the article

  • VMWare Setup with 2 Servers and a DAS (DELL MD3220)

    - by Kumala
    I am planning to use a VMWare based setup consisting of two VMWare servers (2 CPU, 256GB Memory) and a DAS (DELL MD3220 with 24x900GB disks). The virtual machines will be half running MS SQL databases (Application, Sharepoint, BI) and the other half of the VM will be file services, IIS. To enhance the capacity of the storage, we'll be adding a MD1220 enclosure with another 24x900GB to the MD3220. Both DAS will have 2 controllers. Our current measured IOPS is 1000 IOPS average, 7000 IOPS peak (those happen maybe twice per hour). We are in the planning phase now and are looking at the proper setup of the disks. The intention is to setup up both DAS one of the DAS with RAID 10 only and the other DAS with RAID 5. That will allow us to put the applications on the DAS that supports the application performance needs best. Question is how best to partition the two DASs to get best possible IOPS/MBps, each DAS will have to have 2 hot spares? For the RAID 5 Setup: Generally speaking, would it be better to have one single disk group across all 22 disks (24 - 2 hot spares) with both controllers assigned to the one disk group or is it better to have 2 disk groups each 11 disks, assigned to one of the two controllers? Same question for the RAID 10 setup: The plan is: 2 disks for logs (Raid 1), 2 Hotspare and 20 disks for RAID 10. Option 1: 5 * 4 disks (RAID 10), with two groups assigned to 1 controller and 3 groups to the other controller Option 2: One large RAID 10 across all the disks and have both controllers assigned to the same group? I would assume that there is no right or wrong, but it all depends very much on the specific application behaviour, so I am looking for some general ideas what the pros and cons are of the different options. IF there are other meaningful options, feel free to propose them.

    Read the article

  • Access to File being restricted after Ubuntu crashed

    - by Tim
    My Ubuntu 8.10 crashed due to the overheating problem of the CPU when I am opening some directory and intend to do some file transfer under Nautilus. After reboot, under gnome, all the files cannot be removed, their properties cannot be viewed and they can only be opened, although all are still fine under terminal. I was wondering why is that and how can I fix it? Thanks and regards UPdate $ cat /etc/mtab /dev/sda7 / ext3 rw,relatime,errors=remount-ro 0 0 tmpfs /lib/init/rw tmpfs rw,nosuid,mode=0755 0 0 /proc /proc proc rw,noexec,nosuid,nodev 0 0 sysfs /sys sysfs rw,noexec,nosuid,nodev 0 0 varrun /var/run tmpfs rw,nosuid,mode=0755 0 0 varlock /var/lock tmpfs rw,noexec,nosuid,nodev,mode=1777 0 0 udev /dev tmpfs rw,mode=0755 0 0 tmpfs /dev/shm tmpfs rw,nosuid,nodev 0 0 devpts /dev/pts devpts rw,noexec,nosuid,gid=5,mode=620 0 0 fusectl /sys/fs/fuse/connections fusectl rw 0 0 lrm /lib/modules/2.6.27-15-generic/volatile tmpfs rw,mode=755 0 0 /dev/sda8 /home ext3 rw,relatime 0 0 /dev/sda2 /windows-c vfat rw,utf8,umask=007,gid=46 0 0 /dev/sda5 /windows-d fuseblk rw,allow_other,blksize=4096 0 0 securityfs /sys/kernel/security securityfs rw 0 0 binfmt_misc /proc/sys/fs/binfmt_misc binfmt_misc rw,noexec,nosuid,nodev 0 0 gvfs-fuse-daemon /home/tim/.gvfs fuse.gvfs-fuse-daemon rw,nosuid,nodev,user=tim 0 0

    Read the article

  • Distributing processing for an application that wasn't designed with that in mind

    - by Tim
    We've got the application at work that just sits and does a whole bunch of iterative processing on some data files to perform some simulations. This is done by an "old" Win32 application that isn't multi-processor aware, so new(ish) computers and workstations are mostly sitting idle running this application. However, since it's installed by a typical Windows Install Shield installer, I can't seem to install and run multiple copies of the application. The work can be split up manually before processing, enabling the work to be distributed across multiple machines, but we still can't take advantage of multiple core CPUs. The results can be joined back together after processing to make a complete simulation. Is there a product out there that would let me "compartmentalize" an installation (or 4) so I can take advantage of a multi-core CPU? I had thought of using MS Softgrid, but I believe that still depends on a remote server to do the heavy lifting (though please correct me if I'm wrong). Furthermore, is there a way I can distribute the workload off the one machine? So an input could be split into 50 chunks, handed out to 50 machines, and worked on? All without really changing the initial application? In a perfect world, I'd get the application to take advantage of a DesktopGrid (BOINC), but like most "mission critical corporate applications", the need is there, but the money is not. Thank you in advance (and sorry if this isn't appropriate for serverfault).

    Read the article

  • What is the sysadmin's dream network printer? 6-8k pg/mo. Xerox, OkiData, Lexmark and HP are all fail

    - by Jacob
    How do I find out what printer brand and/or type doesn't suck? This information is hard to find and manufacturer's websites won't reveal any issues with certain printers. After 10 years of dealing with network shared printers, I can't say that I have been impressed with any of the printer brands I've seen. Brother's little laser MFPs have been close to ideal for low volume, but that is it, period. OkiData, Lexmark, HP, Xerox solid ink printers, they all sucked in one way or another. Currently I'm looking to replace a Xerox ColorQube 8570 because it fails to print on a regular basis. Sometimes it doesn't even boot VxWorks fully - it just hangs at 2% or whatever. I've used Xerox 8860MFPs and they sucked just as bad. I won't talk about ink jets here, that's most likely not what I'm looking for. We currently spend about $4k on paper and ink per year for this printer at up to 6-8k pages per month, letter, mostly black and white, low color usage. I want the printer to feed paper correctly, not crash and burn when a PDF isn't according to its taste (my favorite Xerox problem here) and with decent drivers for Windows and OS X. Print quality is not of the utmost importance but paper does get sent to customers.

    Read the article

  • Wireless card on HP laptop not working

    - by D. Strout
    I just bought an HP Envy m6-1125dx online from Best Buy. When I got it home and started it up, the wireless card did not work well - at all. I could connect, but any real usage would cause the connection to start dropping every 30 seconds or so, and it would be really slow. Taking another look at the reviews on the Best Buy site, it seems only a few others had this problem, so I took it to my local Best Buy and exchanged it for another unit. Got it home again and the card had the same issues. Which leads to my dilemma. First: does this model have several different cards that it could come with? Mine is a Ralink RT5390R (on both units I received). If it does, then I can keep exchanging until I get a unit with a different card. I wouldn't ask this, except it seems weird that only a few people mentioned this issue, so I thought that might be one possibility. I looked in to replacing the card with a different one myself, but it seems that HP blocks certain wireless cards. However, some people reported success in replacing the card, and this site said it was only an issue on "older HP computer[s]". Can anyone confirm this? Finally, if that fails/will not work, does anyone know what I can get through Best Buy? I am concerned that they will not put any different card than the Ralink, and after two of those, I don't want that. Can I ask Best Buy support to use a different card? Can they even get another card from HP? I guess the base question is: should I attempt to replace the card myself (two days via Amazon to get a new card), should I try to get the laptop repaired through Best Buy (two - four weeks), should I go for a different model laptop from Best Buy, or should I try a different unit of the same model (three's the charm?).

    Read the article

  • How can I determine what is killing my network adapter win7 or vista?

    - by datatoo
    I thought this issue was like another person here, and that downloading the nvidia chipset drivers was the solution. However that is not all that is going on. This machine had Vista 64bit and is now Win7. Same issue with both. I have explicitly been denying network driver updates since getting things working again and when a Windows updates occurs on seemingly benign Office updates the adapter fails to work. Is the update process somehow protecting this machine by turning off things and it fails to recover connectivity after a restart? All that seems to ever work is a system restore. Which does work. Since there are 25 pending updates asking to do there thing, I hate to think this is a one by one update test to find the culprit. Any ideas? This has an integrated nic, video, and I guess audio on the motherboard. ES5200 intel cpu on a gateway 4800-05e I am not quite sure how to determine the actual network adapter. This is a wired adapter. I suppose worst case I can try another adapter if this keeps happening.

    Read the article

  • Missing MB on a GPT partioned SSD

    - by pisswillis
    I recently installed Arch Linux on an Intel 40GB SSD. I used GPT for partioning (via GNU parted) and created the following partions: /dev/sda1 : 1 MB, no FS, flag=bios_grub /dev/sda2 : 30MB, /boot, ext2, flag=boot /dev/sda3 : 20GB, /home, ext4 /dev/sda4 : ~20GB, /, ext4 After struggling to install grub2 from the livecd environment (which I finally did via grub-install /dev/sda --root-directory=/mnt/ --no-floppy --force) I got a working system. However, when I was inspecting disk usage with df I noticed that my home partition had around 170MB of used space on it. This surprised me because the only things on /home were one users .bashrc, .bash_history, and .lesshst. du confirmed that there was only a few KB of space being used on /home. Why does df report approximately 170MB being used when du does not? Is this space "gone forever", or can I regain it by repartioning and/or reinstalling? When I installed grub2 it said something along the lines of "your embed area is too small", and that I could "use BLOCKLISTS, but BLOCKLISTS are UNRELIABLE". In the end the only way I could get a system booting from the SSD was to use blocklists via the grub-install --force flag. Is this related to the mysterious missing 170MB? Thanks

    Read the article

  • erlyvideo server doesn't start automatically after reboot

    - by electroid
    I have installed erlyvideo server on ubuntu 9.10 karmic koala. Everything works fine, but after server reboot I have to start erlyvideo server manually with /etc/init.d/erlyvideo start. I try allready update-rc.d and I think erlyvideo by default should start automaticaly. Any help will be appreciated. Here erlyvideo startup script located in /etc/init.d/erlyvideo: #!/bin/sh ### BEGIN INIT INFO # Provides: erlyvideo # Required-Start: $local_fs $network # Required-Stop: $local_fs $network # Default-Start: 2 3 4 5 # Default-Stop: 0 1 6 # Short-Description: starts the erlyvideo streaming server # Description: starts the erlyvideo using erlang system ### END INIT INFO case "$1" in start) cd /opt/erlyvideo && ./bin/erlyvideo "$1" ;; stop) cd /opt/erlyvideo && ./bin/erlyvideo "$1" ;; restart) cd /opt/erlyvideo && ./bin/erlyvideo "$1" ;; soft-restart) cd /opt/erlyvideo && ./bin/erlyvideo "$1" ;; upgrade) cd /opt/erlyvideo && ./bin/erlyvideo "$1" ;; reconfigure) cd /opt/erlyvideo && ./bin/erlyvideo "$1" ;; reboot) cd /opt/erlyvideo && ./bin/erlyvideo "$1" ;; ping) cd /opt/erlyvideo && ./bin/erlyvideo "$1" ;; console) cd /opt/erlyvideo && ./bin/erlyvideo "$1" ;; attach) cd /opt/erlyvideo && ./bin/erlyvideo "$1" ;; attach-erl) cd /opt/erlyvideo && ./erts-5.8.4/bin/erl -name [email protected] -remsh [email protected] ;; *) echo $"Usage: $0 {start|stop|restart|soft-restart|upgrade|reboot|ping|console|attach}" exit 1 esac exit 0 And I have found S91erlyvideo in /etc/rc2.d next to S91apache2 which starts just fine on every reboot.

    Read the article

  • Server stops responding, can't find issue?

    - by Corey W
    I've had a pretty basic server up and running CentOS with webserver/database, and have noticed that it has locked up a few times in the middle of the night. It seems to happen randomly. When it locks up I can ssh in, (although it seems to hang once connected), but can't access cpanel/whm and have to reboot the server to get everything back up. Checking the messages log I see the below like clockwork every 5minutes 1 second, and then it just stops logging anything until I reboot. I can't seem to find any log showing any issue? Is there somewhere I can check to try to figure out what is happening? Could this be caused by CPU being maxed? Nov 17 08:01:35 s1 pure-ftpd: (__cpanel__service__auth__ftpd__Q13SKrtaCJCHjBezTfU8Iqmsi@127.0.0.1) [INFO] Logout. Nov 17 08:06:36 s1 pure-ftpd: ([email protected]) [INFO] New connection from 127.0.0.1 Nov 17 08:06:36 s1 pure-ftpd: ([email protected]) [INFO] __cpanel__service__auth__ftpd__mxidFBSnQXmR0QzqSxlqrXLIH0CmJ0GPh9bZ5V3 is now l ogged in Nov 17 08:06:37 s1 pure-ftpd: (__cpanel__service__auth__ftpd__mxidBDaCgnqSxlqrXLIH0CmJ0GPh9bZ5V3@127.0.0.1) [INFO] Logout. Nov 17 08:11:37 s1 pure-ftpd: ([email protected]) [INFO] New connection from 127.0.0.1 Nov 17 08:11:38 s1 pure-ftpd: ([email protected]) [INFO] __cpanel__service__auth__ftpd__T4B7F71acf1dsdJSeJHdqKNcbOdpzNnN_GttgcM is now l ogged in Nov 17 08:11:38 s1 pure-ftpd: (__cpanel__service__auth__ftpd__T4B7F71acf1KNcbOdpzNnN_GttgcM@127.0.0.1) [INFO] Logout. Nov 17 08:16:38 s1 pure-ftpd: ([email protected]) [INFO] New connection from 127.0.0.1 Nov 17 08:16:38 s1 pure-ftpd: ([email protected]) [INFO] __cpanel__service__auth__ftpd__W5C1RzumtaNwe4cU8Lt1 is now logged in Nov 17 08:16:38 s1 pure-ftpd: ([email protected]) [INFO] Logout. Nov 17 09:10:58 s1 kernel: imklog 4.6.2, log source = /proc/kmsg started. Nov 17 09:10:58 s1 rsyslogd: [origin software="rsyslogd" swVersion="4.6.2" x-pid="1094" x-info="http://www.rsyslog.com"] (re)start Nov 17 09:10:58 s1 kernel: Initializing cgroup subsys cpuset

    Read the article

  • What Is The Proper Laptop Battery Care While Running Laptop Solely On Battery?

    - by Boris_yo
    Because of convenience, I had to move my laptop to another room away from room where I always ran laptop on UPS without using battery. Since so far I always run laptop on battery, I question the proper usage to prolong battery life. Currently I run laptop on battery with power supply so battery is constantly being charged until it is full 100% and when it is, I disconnect power supply and continue working until battery meter shows 10% remaining. That's when I plug in power supply and let it charge until 100% once again while I work. But it takes a lot of time to fully charge laptop while working since my power supply is 60W which should be the reason of such slow charge and I think the kind of charger that I use is express charger. The thought of charging laptop until full, all while doing my work makes me think that if it takes way more time to charge, it might keep battery running warm for the period of charging time which brings me to question about whether I should keep running laptop as I've described above or it would be better to leave power supply constantly connected to laptop to keep battery between 99%-100%? On one hand it won't keep battery warm but it will try to frequently supply charge to battery once it gets 99% to replenish charge to 100% (which might reduce battery life?). On the other hand if I'll keep working solely on battery and recharge it when below 10%, the battery will get warm but only when charged. Can anybody suggest the correct way of running laptop on battery to ensure better battery life? Dell Latitude E6420 Windows 7 64-bit

    Read the article

  • Vista Screen resolution Changes when Switching Users

    - by Benjol
    I regularly have a problem when switching between users in Vista - the screen resolution drops down to 800x600. If I try to set the resolution back to the maximum, it says nothing, but just keeps it at 800x600. I can set it back to an intermediate value. Otherwise I have to either restart the PC, or sometimes if I log off one of the users, I can then set the resolution back to max. Might it also have something to do with using sleep mode instead of performing regular shutdowns? I thought it might be related to the desktop background image taking up too much space, but even with plain colours, the problem still occurs. There is an enormous thread on this here, but not really any answers. From what I can gather from that thread, it isn't related to any particular applications, nor limited to a particular make of graphics card or monitor, so I don't think that including hardware details is useful. This is a very annoying problem, as it screws up my desktop and screen layout every single time. Has anyone here experienced this problem or found a solution? I've noticed that Windows Update has tried to install nVidia updates and apparently they've failed on several occasions. Not sure if that is of any relevance or not. UPDATE The last post on the thread: FWIW - I had this problem for about 2 years and wrote a number of posts in this thread in the past. It survived OS reinstallation, change of practically all of my hardware piece by piece (mobo, cpu, monitor, graphics card, memory, power supply...) I used to be affected by this annoying problem at least once every 24-48 hours. About 1.5 months ago I wiped out my 32 bit vista ultimate installation and installed Windows7 ultimate 64 bit from scratch and never saw this problem again. GOOD RIDDANCE. Vista was a pathetic piece of __ that felt like a flashback to the old [horrible] NT4/Windows95 days. I was seriously considering switching over to Apple/Mac OSX if this problem persisted.

    Read the article

< Previous Page | 327 328 329 330 331 332 333 334 335 336 337 338  | Next Page >