Search Results

Search found 71537 results on 2862 pages for 'virtual com port'.

Page 38/2862 | < Previous Page | 34 35 36 37 38 39 40 41 42 43 44 45  | Next Page >

  • How to connect 2 virtual hosts running on the same machine?

    - by Gabrielle
    I have 2 virtual hosts running on my Windows XP laptop. One is Ubuntu running inside vmware player. The other is MS virtual PC (so I can test with IE6 ). The Ubuntu virtual host is running my web application with apache. I can point my browser on my laptop at the Ubuntu IP and view my web app. I read this post http://stackoverflow.com/questions/197792/how-to-connect-to-host-machine-from-within-virtual-pc-image and was able to get my Virtual PC to ping my physical machine using the loopback adapter. But I'm stuck on getting my Virtual PC to see my web application running in the Ubuntu vmware player host. I appreciate any suggestions.

    Read the article

  • Getting Drag and Drop to Work in Virtual PC 2007 on Windows 7.

    - by Kryten
    Hi, I have Virtual PC 2007 installed on my Windows 7 machine. Before anyone asks, I have installed VPC 2007 because my machine does not support the new Virtual PC for Windows 7. Everythings working fine, except for the drag and drop file feature. On my old Windows XP machine the drag and drop feature works fine, but on Windows 7, nothing happens. I just get the "no drop" cursor. I HAVE installed Virtual Machine Additions and have run Virtual PC under XP Compatability, but still nothing. The Virtual Machines I have tried draging and dropping files onto on are: Windows 2000 Windows XP Windows 98 and as I said they all have Virtual Machine Additions on them. Whats going on? How can I get the drag and drop feature working? I did see this question, but it still doesn't answer my question.

    Read the article

  • error while installing ia32-libs

    - by user3405516
    I am trying to install "ia32-libs" After doing google I did following steps. Yet not able to do it... 1st step i have added dpkg --add-architecture i386 2nd step added "deb http://archive.ubuntu.com/ubuntu/ raring main restricted universe multiverse" ia32-libs-raring.list" root@user:/etc/apt/sources.list.d# sudo dpkg --add-architecture i386 root@user:/etc/apt/sources.list.d# echo "deb http://archive.ubuntu.com/ubuntu/ raring main restricted universe multiverse" >ia32-libs-raring.list root@user:/etc/apt/sources.list.d# apt-get update Ign http://us-east-1.ec2.archive.ubuntu.com trusty InRelease Ign http://security.ubuntu.com trusty-security InRelease Ign http://archive.ubuntu.com raring InRelease Ign http://us-east-1.ec2.archive.ubuntu.com trusty-updates InRelease Hit http://security.ubuntu.com trusty-security Release.gpg Ign http://archive.ubuntu.com raring Release.gpg Hit http://us-east-1.ec2.archive.ubuntu.com trusty Release.gpg Hit http://security.ubuntu.com trusty-security Release Hit http://us-east-1.ec2.archive.ubuntu.com trusty-updates Release.gpg Ign http://archive.ubuntu.com raring Release Hit http://us-east-1.ec2.archive.ubuntu.com trusty Release Hit http://us-east-1.ec2.archive.ubuntu.com trusty-updates Release Hit http://security.ubuntu.com trusty-security/main Sources Hit http://us-east-1.ec2.archive.ubuntu.com trusty/main Sources Hit http://security.ubuntu.com trusty-security/universe Sources Hit http://us-east-1.ec2.archive.ubuntu.com trusty/universe Sources Hit http://security.ubuntu.com trusty-security/main amd64 Packages Hit http://us-east-1.ec2.archive.ubuntu.com trusty/main amd64 Packages Hit http://security.ubuntu.com trusty-security/universe amd64 Packages Hit http://us-east-1.ec2.archive.ubuntu.com trusty/universe amd64 Packages Hit http://security.ubuntu.com trusty-security/main i386 Packages Hit http://us-east-1.ec2.archive.ubuntu.com trusty/main i386 Packages Hit http://security.ubuntu.com trusty-security/universe i386 Packages Hit http://us-east-1.ec2.archive.ubuntu.com trusty/universe i386 Packages Hit http://security.ubuntu.com trusty-security/main Translation-en Hit http://security.ubuntu.com trusty-security/universe Translation-en Hit http://us-east-1.ec2.archive.ubuntu.com trusty/main Translation-en Hit http://us-east-1.ec2.archive.ubuntu.com trusty/universe Translation-en Hit http://us-east-1.ec2.archive.ubuntu.com trusty-updates/main Sources Hit http://us-east-1.ec2.archive.ubuntu.com trusty-updates/universe Sources Hit http://us-east-1.ec2.archive.ubuntu.com trusty-updates/main amd64 Packages Hit http://us-east-1.ec2.archive.ubuntu.com trusty-updates/universe amd64 Packages Hit http://us-east-1.ec2.archive.ubuntu.com trusty-updates/main i386 Packages Hit http://us-east-1.ec2.archive.ubuntu.com trusty-updates/universe i386 Packages Hit http://us-east-1.ec2.archive.ubuntu.com trusty-updates/main Translation-en Hit http://us-east-1.ec2.archive.ubuntu.com trusty-updates/universe Translation-en Ign http://us-east-1.ec2.archive.ubuntu.com trusty/main Translation-en_US Ign http://us-east-1.ec2.archive.ubuntu.com trusty/universe Translation-en_US Err http://archive.ubuntu.com raring/main amd64 Packages 404 Not Found [IP: 91.189.91.13 80] Err http://archive.ubuntu.com raring/restricted amd64 Packages 404 Not Found [IP: 91.189.91.13 80] Err http://archive.ubuntu.com raring/universe amd64 Packages 404 Not Found [IP: 91.189.91.13 80] Err http://archive.ubuntu.com raring/multiverse amd64 Packages 404 Not Found [IP: 91.189.91.13 80] Err http://archive.ubuntu.com raring/main i386 Packages 404 Not Found [IP: 91.189.91.13 80] Err http://archive.ubuntu.com raring/restricted i386 Packages 404 Not Found [IP: 91.189.91.13 80] Err http://archive.ubuntu.com raring/universe i386 Packages 404 Not Found [IP: 91.189.91.13 80] Err http://archive.ubuntu.com raring/multiverse i386 Packages 404 Not Found [IP: 91.189.91.13 80] Ign http://archive.ubuntu.com raring/main Translation-en_US Ign http://archive.ubuntu.com raring/main Translation-en Ign http://archive.ubuntu.com raring/multiverse Translation-en_US Ign http://archive.ubuntu.com raring/multiverse Translation-en Ign http://archive.ubuntu.com raring/restricted Translation-en_US Ign http://archive.ubuntu.com raring/restricted Translation-en Ign http://archive.ubuntu.com raring/universe Translation-en_US Ign http://archive.ubuntu.com raring/universe Translation-en W: Failed to fetch http://archive.ubuntu.com/ubuntu/dists/raring/main/binary-amd64/Packages 404 Not Found [IP: 91.189.91.13 80] W: Failed to fetch http://archive.ubuntu.com/ubuntu/dists/raring/restricted/binary-amd64/Packages 404 Not Found [IP: 91.189.91.13 80] W: Failed to fetch http://archive.ubuntu.com/ubuntu/dists/raring/universe/binary-amd64/Packages 404 Not Found [IP: 91.189.91.13 80] W: Failed to fetch http://archive.ubuntu.com/ubuntu/dists/raring/multiverse/binary-amd64/Packages 404 Not Found [IP: 91.189.91.13 80] W: Failed to fetch http://archive.ubuntu.com/ubuntu/dists/raring/main/binary-i386/Packages 404 Not Found [IP: 91.189.91.13 80] W: Failed to fetch http://archive.ubuntu.com/ubuntu/dists/raring/restricted/binary-i386/Packages 404 Not Found [IP: 91.189.91.13 80] W: Failed to fetch http://archive.ubuntu.com/ubuntu/dists/raring/universe/binary-i386/Packages 404 Not Found [IP: 91.189.91.13 80] W: Failed to fetch http://archive.ubuntu.com/ubuntu/dists/raring/multiverse/binary-i386/Packages 404 Not Found [IP: 91.189.91.13 80] E: Some index files failed to download. They have been ignored, or old ones used instead.

    Read the article

  • How to diagnose cause, fix, or work around Adobe ActiveX / COM related error 0x80004005 progmaticall

    - by Streamline
    I've built a C# .NET app that uses the Adobe ActiveX control to display a PDF. It relies on a couple DLLs that get shipped with the application. These DLLs interact with the locally installed Adobe Acrobat or Adobe Acrobat Reader installed on the machine. This app is being used by some customer already and works great for nearly all users ( I check to see that the local machine is running at least version 9 of either Acrobat or Reader already ). I've found 3 cases where the app returns the error message "Error HRESULT E_FAIL has been returned from a call to a COM component" when trying to load (when the activex control is loading). I've checked one of these user's machines and he has Acrobat 9 installed and is using it frequently with no problems. It does appear that Acrobat 7 and 8 were installed at one time since there are entries for them in the registry along with Acrobat 9. I can't reproduce this problem locally, so I am not sure exactly which direction to go. The error at the top of the stacktrace is: System.Runtime.InteropServices.COMException (0x80004005): Error HRESULT E_FAIL has been returned from a call to a COM component. Some research into this error indicates it is a registry problem. Does anyone have a clue as to how to fix or work around this problem, or determine how to get to the core root of the problem? The full content of the error message is this: System.Runtime.InteropServices.COMException (0x80004005): Error HRESULT E_FAIL has been returned from a call to a COM component.    at System.Windows.Forms.UnsafeNativeMethods.CoCreateInstance(Guid& clsid, Object punkOuter, Int32 context, Guid& iid)    at System.Windows.Forms.AxHost.CreateWithoutLicense(Guid clsid)    at System.Windows.Forms.AxHost.CreateWithLicense(String license, Guid clsid)    at System.Windows.Forms.AxHost.CreateInstanceCore(Guid clsid)    at System.Windows.Forms.AxHost.CreateInstance()    at System.Windows.Forms.AxHost.GetOcxCreate()    at System.Windows.Forms.AxHost.TransitionUpTo(Int32 state)    at System.Windows.Forms.AxHost.CreateHandle()    at System.Windows.Forms.Control.CreateControl(Boolean fIgnoreVisible)    at System.Windows.Forms.Control.CreateControl(Boolean fIgnoreVisible)    at System.Windows.Forms.AxHost.EndInit()    at AcrobatChecker.Viewer.InitializeComponent()    at AcrobatChecker.Viewer..ctor()    at AcrobatChecker.Form1.btnViewer_Click(Object sender, EventArgs e)    at System.Windows.Forms.Control.OnClick(EventArgs e)    at System.Windows.Forms.Button.OnClick(EventArgs e)    at System.Windows.Forms.Button.OnMouseUp(MouseEventArgs mevent)    at System.Windows.Forms.Control.WmMouseUp(Message& m, MouseButtons button, Int32 clicks)    at System.Windows.Forms.Control.WndProc(Message& m)    at System.Windows.Forms.ButtonBase.WndProc(Message& m)    at System.Windows.Forms.Button.WndProc(Message& m)    at System.Windows.Forms.Control.ControlNativeWindow.OnMessage(Message& m)    at System.Windows.Forms.Control.ControlNativeWindow.WndProc(Message& m)    at System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam)

    Read the article

  • Outlook 2003 add-in - Getting COM exception on application shutdown after creating WPF window

    - by Oliver Hanappi
    Hi! I'm developing an outlook 2003 add-in. Until now I used only winforms to display one form, but today I've added a WPF window for more complex stuff. DUe to the WPF window, a COM exception is being thrown when outlook shuts down. Does anybody know why? I need to start a separate thread for the WPF window in single apartment state. Here is the exception: System.Runtime.InteropServices.InvalidComObjectException was unhandled Message="COM object that has been separated from its underlying RCW cannot be used." Source="PresentationCore" StackTrace: at System.Windows.Input.TextServicesContext.StopTransitoryExtension() at System.Windows.Input.TextServicesContext.Uninitialize(Boolean appDomainShutdown) at System.Windows.Input.TextServicesContext.TextServicesContextShutDownListener.OnShutDown(Object target) at MS.Internal.ShutDownListener.HandleShutDown(Object sender, EventArgs e) InnerException: Best Regards, Oliver Hanappi

    Read the article

  • Loose coupling of COM in C# or How to avoid COMException 0x80040154

    - by user283318
    I have a .Net 2 C# application I am developing which uses a VB 6 generated COM DLL. The VB DLL is updated frequently any my application crashes with a System.Runtime.InteropServices.COMException (0x80040154). The part of the COM DLL I use does not change but the version (and CLSID) will. The "Specific Version" option for the reference is false. The WrapperTool is tlbimp. How do I tell my application not to worry about changes in the DLL? Is there any way of checking just the functions I am using?

    Read the article

  • Good freeware COM/ActiveX Type Library Explorer?

    - by Tomalak
    I used to have a dated, but valuable solution to display COM/ActiveX control- and type-library contents (ProgIDs, method names and signatures, enumerations, constants, interfaces/coclasses, etc.) of all such libraries registered on my system. It provided an Explorer-like overview of everything that was available to ActiveX development/scripting and served as an automatic API documentation tool since official docs for most COM/ActiveX libraries are either missing completely or fragmentary at best. My recent move to a 64bit Windows rendered the program I had unusable, due to internal dependencies on the 32bit VB6 runtime (comctl32.ocx) that is no longer supported on 64bit Windows. Does anyone know an alternative that still works?

    Read the article

  • Python Access Parallel Port

    - by PPTim
    Hi, I've been trying to access the parallel port with pyParallel, which is in the same sourceforge as PySerial: http://sourceforge.net/projects/pyserial/files/ I'm getting a WidowsError: exception: priviledged instruciton. Has anyone used this module before? import parallel p = parallel.Parallel() Traceback (most recent call last): File "<interactive input>", line 1, in <module> File "C:\Python26\lib\site-packages\parallel\parallelwin32.py", line 74, in __init__ self.ctrlReg = _pyparallel.inp(self.ctrlRegAdr) WindowsError: exception: priviledged instruction

    Read the article

  • Using COM to open Word

    - by chupinette
    Hello! I am actually trying some codes i found from http://php.net/manual/en/class.com.php <?php // starting word $word = new COM("word.application") or die("Unable to instantiate Word"); echo "Loaded Word, version {$word->Version}\n"; //bring it to front $word->Visible = 1; //open an empty document $word->Documents->Add(); //do some weird stuff $word->Selection->TypeText("This is a test..."); $word->Documents[1]->SaveAs("Useless test.doc"); //closing word $word->Quit(); //free the object $word = null; ?> But this does not seem to work. I am using Word 2007 and i get the following: Loaded Word, version 12.0 Fatal error: Call to undefined method variant::SaveAs() in C:\xampp\htdocs\final\testq.php on line 14 Can anyone solve this problem? Is it because i am using Word 2007?

    Read the article

  • How does COM registration work in Windows

    - by Air Benji
    I'm an application packager trying to make sense of how the COM registry keys (SelfReg) interrelate to the given .dll in Windows. ProgID's, AppID's, TypeLibs, Extensions & Verbs are all tied around the CLSID right? Do CLSID's always use Prog/App IDs or could you just have a file extension class? Which bits are optional? Some of it seems to be 'like a router' where there's the two interfaces (internal - .dll) and external (the extension etc). How does this all fit? (The SDK documentation doesn't make sense to me) I ask as this is all pivotal to application 'healing' with Windows Installer (which packagers are all 'big' on, but there's no nitty-gritty breakdowns since its a coder-thing really) ---Edit: Am I safe in assuming that for what COM is registered, it must all link back to the CLSID and cannot be a 'dead-end'? Verbs need extensions which need progid's... What about the AppId's, TypeLibs and Interfaces? How do they interrelate?

    Read the article

  • Exposing .NET enums to COM clients{VBScript}

    - by Codex
    Am trying create of PoC for exposing/invoking various .NET objects from COM clients. The .NET library contains some classes and Enums. Am able to successfully access the classes in VBScript but not able to access the Enums. I know that Enums are value types and hence 'CreateObject' wont work in this case. But am able to access the same Enum in VBA code. Questions: How can I access the enums in VBScript? Why does the behaviour differ in the two COM clients? If VBA object browser can see the enum, why cant VBScript allow me to create one? .NET [ComVisible(true)] [GuidAttribute("ebc25cf6-9120-4283-b972-0e5520d0000E")] public enum Currency { GBP = CurrencyConvertorBL.CurrencyConvertorRef.Currency.GBP, USD = CurrencyConvertorBL.CurrencyConvertorRef.Currency.USD, INR = CurrencyConvertorBL.CurrencyConvertorRef.Currency.INR, AUD = CurrencyConvertorBL.CurrencyConvertorRef.Currency.AUD } VBA Private Function ConvertCurrency(fromCurrency As Currency, toCurrency As Currency) As Double VBScript ??? Set currencyConvertorCCY = CreateObject("CurrencyConvertorBL.Currency") Thanks in advance.

    Read the article

  • Passing a string from C# to cpp with COM

    - by Yaron Naveh
    I have a C# COM server which is consumed by a cpp client. One of the C# methods returns a string. In cpp the returned string is represented in Unicode (UTF-16), at least according to the memory view. Is this always the case with COM strings? Is there a way to use UTF-8 instead? I saw some code where strings were passed between cpp and c# as byte arrays. Is there any benefit in this?

    Read the article

  • any command line com port query tools?

    - by c_programmer
    ok folks, heres my dilemma i want to make a chat program that uses sms as its base engine.. to do this i need to communicate with my gsm phone via bluetooth attached to com 7 on my computer.. i can do this fine using hyperterminal, tera term etc. but to hav an un-obtrusive, friendly interface i need a command line tool to send AT commands, (and receive responses) to/from my mobile phone through my com port.. i have been searching for days to no avail.. please help

    Read the article

  • Invoke a COM addin option from VBA

    - by rip
    Can I invoke an option on a COM Add-in from a VBA macro in Word or Excel 2007? The COM Add-in was written using VSTO – it adds a custom ribbon tab with a number of options that I want to execute from a VBA macro. I can reference the add-in using Application.COMAddIns("MyAddinName") but I can’t find an option to invoke an option. I’ve also played around with the Application.CommandBars collection, and can see that you can execute an option using CommandBarControl.Execute but I can’t find my command bar in the Application.CommandBars collection. Does anyone know if this is possible?

    Read the article

  • Explore a COM Object in PHP

    - by shaiss
    What would be the proper way to explode a COM object for debugging? I have a 3rd party function that returns a multilevel object. The documentation is non existant, so I'd like to be able to echo everything out of the object or debug it in Komodo IDE. Komodo just says Object and nothing else. Maybe convert to array? I know some of the existing options such as $com->Status, but there are more variables returned that I'd like to know what they are.

    Read the article

  • Monitor serial port already open

    - by Cristiano
    Hi, I am try to read data over serial port already open. I have used C# and c++ library for use microsoft api (overlapped and not overlapped I/O), but not work. I can use same windows api? or other?? Thanks in advance for your availability, Cristiano http://bugbusters.altervista.org/index.php

    Read the article

  • running a parallel port controlling program through php.

    - by prateek
    I have a program that is interacting with hardware via parallel port programming. i had compiled it and using its object file to interact with the hardware (a simple led). when i execute it directly on the shell it serves the purpose of glowing the LED but when i execute it using shell_exec() in php the command is executed but unable to interact with the hardware. i am totally confused.. .

    Read the article

  • Getting the version of a COM object

    - by Shao
    I am accessing a .NET COM object from C++. I want to know the version information about this COM object. When I open the TLB in OLEVIEW.exe I can see the version information associated with the coclass. How can I access this information from C++? This is the information I get: [ uuid(XXXXXXXX-XXXX-XXXX-XXXX-XXXXXXXXXXXX), version(1.0), custom(XXXXXXXX-XXXX-XXXX-XXXX-XXXXXXXXXXXX, XXXX) ] coclass XXXXXXXX{ [default] interface XXXXXXXX; interface _Object; interface XXXXXXXX; };

    Read the article

  • Un-enlisting a BizTalk MSMQ send port in batch file

    - by SteveC
    I've got a solution which I setup / cleanup using batch files ... - there are a pair of MSMQ ports, send and receive, with another application on the end of the queues I'm finding I can't properly stop the orchestration in the batch file ... the error is the send port is unenlisted - I'm using the StopOrch.vbs script from the SDK samples But I can go into BizTalk Admin Console and manually stop the orchestration with Full Terminate Ok The setup / cleanup works Ok if I don't actually push any messages down the MSMQ queues

    Read the article

  • Extract a C/C++ header file from a C# class exposed to COM

    - by isorfir
    I'm not sure I've setup everything I've needed to in my C# class to properly, but it does work in COM. I've been looking for an example of a C# class that was successfully used in a C/C++ project, but haven't come across anything. I've tried using the OLE/COM Object View app to open the .tlb file and save as .h, but it gives some errors: MIDL1009: unknown argument ignored; MIDL1001: cannot open input file Studio "Studio" isn't the name of the file, it's Syslog, so that raises a red flag to me. Any ideas?

    Read the article

  • Getting COM object to run in Vista

    - by rainslg
    We expose an interface to our simulation software using a COM/ActiveX object. This worked just fine in XP, but in Vista, we get "Error 429: ActiveX can't create object" when a VB client executes CreateObject(). The COM object has been registered by hand so that the Vista Registry is identical to XP's Registry. I run the VB interface from a DOS window that I started using "Run As Administrator". The client is correctly accessing and reading the Registry as I walk through using the debugger in VB, so it's apparently not a security setting, as near as I can tell. I have also loaded the files into VS2005 (the object was originally created in VS6) and rebuilt them to get a later ATL version, but that hasn't helped - we still get the 429 error. Is this a symptom of UAC problems, or should I be looking for something deeper?

    Read the article

< Previous Page | 34 35 36 37 38 39 40 41 42 43 44 45  | Next Page >