  • Upgrading php from php 5.3 to 5.4 .7

    - by Takingsides
    So, quickly so to speak I have noticed this topic around, I have searched and there are plenty of solutions. However these solutions do not work for me, not only that but I'm intending to learn more about the Debian based OS. Questions I would like to know how to upgrade php5.3 to php 5.4.7 compiling it from source, myself without using a third-party ppa. Is the way (explained below) the correct way of configuring php5.4? I'm new to compiling from source. Set-up I run Ubuntu Server 12.04 64bit. I've currently got: PHP 5.3 MySQL-Server Apache2 Memcached The Problem So I initially installed php5.3 using apt-get. I now wish to upgrade the php 5.4 due to the advantage of traits in OOP and the struct with Arrays and all the other recent patches and such. Possible Solutions I've seen this ondrej/ppa repository, which I refuse to use, given the fact that it may work, but it's an unknown/untrusted source. ALso, i'm not learning how to administer from source, using configure, make and install accordingly. I've seen a solution compiling from source, which is essentially how I was hoping to go about it with some guidance. Conclusion So I didn't just expect to be spoon-fed, and I went out and did some manual reading and atleast started the ball rolling myself; this how far i've got. The first thing I did was su into root (to save the typing sudo all the darn time). $ sudo su The next thing I did was download the latest version of php (5.4.7) and extracted it's contents ready to configure before installing it. $ mkdir php5-new && cd !$ $ wget -O php-5.4.7.tar.bz2 http://php.net/get/php-5.4.7.tar.bz2/from/uk3.php.net/mirror $ bzip2 -d php-5.4.7.tar.bz2 $ tar xvf php-5.4.7.tar.gz $ cd php-5.4.7 $ ./configure --help Finally I decided to have a bash, I looked through the list of options and decided I needed to list ALL of the things I wanted to include in the configuration. $ ./configure --with-mysql --with-apache2 --with-libxml --with-openssl --with-zlib --with-bz2 --with-curl --with-dom --with-gd --with-imap --with-imap-ssl --with-mcrypt --with-mysqli --with-pdo-mysql --with-libxml --enable-ftp --enable-mbstring --enable-soap Finally, the results... When the configuration process had finished, it threw an error: configure: error: xml2-config not found. Please check your libxml2 installation.

    Read the article

  • Suggestions for splitting server roles amongst Hyper-V virtual servers / RAID6 or RAID10? / AppAssure

    - by Anon
    We have 2 Hyper-V hosts at present running 1 virtual server that was converted from a physical box running all roles. My plan is to split the roles over various virtual machines, upgrading to the latest software versions as I go, and use the backup server as a standby in case the main server fails. AppAssure backup software has a feature called Virtual Standby, so the VHD's can be ready to be fired up on the backup server if necessary. Off-site backups will be done via external USB drive for now. I'm just seeking some input/suggestions into how I'm planning to split the roles out amongst various virtual servers. Also, I'm curious how to setup the storage on the servers. We do not have any NAS's, SAN'S or any budget for this. What would the best RAID level be to use? I'm thinking either RAID6 (which is currently used) however I'm concerned about the write speeds, or RAID10 but again I'm worried that I can only lose 1 drive (from the same mirror) as opposed to any 2 with RAID6. I realise I have a hot swap for this, but what if a further drive fails during a rebuild? Is the write penalty of RAID6 worth the extra reliability over RAID10? Or will it be too slow with all the roles I am planning, therefore RAID10 is my only real option? The reason for the needed redundancy is I am the only technician and I'm not always on-site. Options I've considered: 1) 5 drives in RAID6 set, 200gb for host OS, rest for VM storage. 1 drive for hot swap - this is how it is currently setup 2) 4 drives in RAID10 set, 200gb for host OS, rest for VM storage. 2 drives for hot swap 3) 4 drives in RAID10 set for VM storage, 2 drives in RAID1 set for host OS. No drives for hot swap - While this is probably the best option with the amount of drives I have, I don't like the idea of having no hot swap 4) 3 drives in RAID6 set for VM storage, 2 drives in RAID1 set for host OS. 1 drive for hot swap All options give us enough storage capacity for our files, etc. We don't have any budget for extra drives or extra hot swap HD chassis for the servers. We have about 70 clients and about 150 users. MAIN SERVER Intel Xeon 5520 @ 2.27 GHz (2 processors) 16GB RAM 6 x 1TB Seagate Barracuda ES.2 Enterprise SATA drives Intel SRCSATAWB RAID controller Virtual machine workload using Hyper-V on Windows Server 2008 R2: DC01 - Active Directory Domain Controller / DNS server / Global catalog - 1GB RAM DC02 - Active Directory Domain Controller / DNS server / Global catalog - 1GB RAM Member Server - DHCP server, File server, Print server - 1GB RAM SCCM Member Server - 4GB RAM Third Party Software Member Server - A/V server, Ticketing software, etc - 4GB RAM Exchange 2007 - 4GB RAM - however we are probably migrating to a hosted solution, therefore freeing up resources BACKUP SERVER Intel Xeon E5410 @ 2.33GHz (2 processors) 16GB RAM 6 x 2TB WD RE4 SATA drives Intel SRCSASRB RAID controller Virtual machine workload using Hyper-V on Windows Server 2008 R2: AppAssure backup software - 8GB RAM

    Read the article

  • Thinkpad speaker turns mute - Linux Codec issue?

    - by Curlew
    At some point a few days ago the speakers on my Lenovo Thinkpad T410 (Model number: 2537A11) suddenly stopped working randomly. This error happens every time I watch a video or listen to a music file. The sound just abruptly stops. At the moment, I can't produce a single sound no matter what I do. I am using Debian GNU/Linux on this laptop and there doesn't appear to be anything else wrong (the fan is working, no abnormal heat (staying around ~40°C), no other obvious errors or problems). Here is the output of a nice program someone pointed me to: martin@martin:~/Downloads$ sudo python run.py --monitor Using temporary directory: /dev/shm/hda-analyzer You may remove this directory when finished or if you like to download the most recent copy of hda-analyzer tool. Downloading file hda_analyzer.py Downloading file hda_guilib.py Downloading file hda_codec.py Downloading file hda_proc.py Downloading file hda_graph.py Downloading file hda_mixer.py Downloaded all files, executing hda_analyzer.py Watching 1 cards ====================================== Sound is working normally and then it stops and the following lines appear: Diff for codec 0/0 (0x14f15069): --- +++ @@ -164,17 +164,17 @@ Power: setting=D0, actual=D0 Node 0x1f [Pin Complex] wcaps 0x400501: Stereo Pincap 0x00000010: OUT Pin Default 0x901701f0: [Fixed] Speaker at Int N/A Conn = Analog, Color = Unknown DefAssociation = 0xf, Sequence = 0x0 Misc = NO_PRESENCE Pin-ctls: 0x40: OUT - Power: setting=D0, actual=D0 + Power: setting=D3, actual=D3 Connection: 2 0x10* 0x11 Node 0x20 [Pin Complex] wcaps 0x400781: Stereo Digital Pincap 0x00000010: OUT Pin Default 0x40f001f0: [N/A] Other at Ext N/A Conn = Unknown, Color = Unknown DefAssociation = 0xf, Sequence = 0x0 Misc = NO_PRESENCE And now there is also an error in the dmesg output hda-intel: IRQ timing workaround is activated for card #0. Suggest a bigger bdl_pos_adj. I changed the bdl_pos_adj to various numbers (-1, 0, 64, 1024) and either there is no change at all or dmesg reports that the adjustment is too big. I wonder if this bdl_pos_adj is the real reason for the error. Here is my hardware information provided by alsa-info.sh website. Okay, i did some serious testing and even installed Windows and now i officially conclude that this is a hard-ware related issue with my Laptop speakers. Reason: The error occurs in my installed Debian Linux, an Ubuntu Live distribution and Windows XP No error-message appears in all of the OS. The sound just keeps running and i can't hear a thing. I tested different setups, including OSS, ALSA and the pulseaudio server on top If i use my new usb-headphones i can hear sound all the time without any sudden silences. So obviously, although hard to believe, my laptop speakers are not okay (never heard of similar cases). I'll award the bounty to anyone who can point me to good tutorials or the procedure how to exchange my T410 speakers (i still have warranty. The laptop was bought in Germany, but now i am in Denmark). Or to someone who can explain me the output from hda-analyzer (big log above).

    Read the article

  • Monitoring tools that can take high rate and high volume?

    - by Jon Watte
    We're using Cacti with RRDTool to monitor and graph about 100,000 counters spread across about 1,000 Linux-based nodes. However, our current setup generally only gives us 5-minute graphs (with some data being minute-based); we often make changes where seeing feedback in "near real time" would be of value. I'd like approximately a week of 5- or 10-second data, a year of 1-minute data, and 5 years of 10-minute data. I have SSD disks and a dual-hexa-core server to spare. I tried setting up a Graphite/carbon/whisper server, and had about 15 nodes pipe to it, but it only has "average" for the retention function when promoting to older buckets. This is almost useless -- I'd like min, max, average, standard deviation, and perhaps "total sum" and "number of samples" or perhaps "95th percentile" available. The developer claims there's a new back-end "in beta" that allows you to write your own function, but this appears to still only do 1:1 retention (when saving older data, you really want the statistics calculated into many streams from a single input. Also, "in beta" seems a little risky for this installation. If I'm wrong about this assumption, I'd be happy to be shown my error! I've heard Zabbix recommended, but it puts data into MySQL or some other SQL database. 100,000 counters on a 5 second interval means 20,000 tps, and while I have an SSD, I don't have an 8-way RAID-6 with battery backup cache, which I think I'd need for that to work out :-) Again, if that's actually something that's not a problem, I'd be happy to be shown the error of my ways. Also, can Zabbix do the single data stream - promote with statistics thing? Finally, Munin claims to have a new 2.0 coming out "in beta" right now, and it boasts custom retention plans. However, again, it's that "in beta" part -- has anyone used that for real, and at scale? How did it perform, if so? I'm almost thinking about using a graphing front-end (such as Graphite) and rolling my own retention backend with a simple layer on top of mmap() and some stats. That wouldn't be particularly hard, and would probably perform very well, letting the kernel figure out the balance between frequency of flushing to disk and process operations. Any other suggestions I should look into? Note: it has to have shown itself able to sustain the kinds of data loads I'm suggesting above; if you can point at the specific implementation you're referencing, so much the better!

    Read the article

  • Windows 2003 Storage Server Hanging on Large File Transfers

    - by user25272
    In one of our offices we have a Dell PowerVault 745N NAS device which acts as the main file server. Its running 32bit Windows 2003 Storage Server SP2 with 3GB RAM. The server holds around 60 users HOME folders, which are mapped via AD. The office clients are a mix of XP SP3, Vista and Windows 7. Occasionally the server will completely hang when transferring large files. When the hang happens the console becomes unresponsive with only the mouse active and blank wallpaper. Sometimes stopping the copy frees the server, sometimes not. The hanging can last around 20 minutes. During this time other servers also become unresponsive with blank wallpaper at the console. If you do manage to get onto another server the taskbar and run commands are unresponsive. This also transcends to the client computers sometimes with explorer crashing. I'm guessing this is due to the HOME folder mapping. Eventually the NAS server with free up and everything will be back to normal. The server is configured as follows: PERC 4/DC DATA 2 - 12 SCSI HDD - RAID5 SHADOWCOPY 2 SCSI HDD - RAID1 CERC SATA DATA 11 4 SATA HDD - RAID5 OS 4 SATA HDD - RAID5 All the drivers and firmware is up to date. I've been through all the diagnostics with Dell and the hardware has come up clean including full HDD tests on the arrays. The server has NOD32 installed as the AV, but the hanging happens when it is uninstalled. There are no errors in the event log when this happens and we don't have any errors logged on any of our ProCurve switches. DNS is fine on the domain and AD from what I can tell is running happily. There are no DFS or NFS shares setup either. All the shares are standard Windows. I've unchecked the allow the computer to turn off this device to save power box under Power Management on the NIC. "Set Link Speed and Duplex to Auto-negotiate 1000 " Increased Receive Descriptors buffer from 256 to 352 (reserves more CPU resource for handling data) I've run network traces using network monitor and have found the following: 417 8.078125 {SMB:192, NbtSS:25, TCP:24, IPv4:23} 192.168.2.244 192.168.5.35 SMB SMB:R; Nt Create Andx - NT Status: System - Error, Code = (52) STATUS_OBJECT_NAME_NOT_FOUND I've tried different cabling; NICs and switch ports all with the same result. Transferring files from other servers on the domain is fine. All I haven't done is run CHKDSK on the drives to look for any file system errors. On the Vista clients I have also run netsh interface tcp set global autotuning=disabled with no result. Could it be that the server has a faulty drive or that the I/O is too much for it to handle? Any ideas why would the hang cause issues with the other servers on the LAN? Many Thanks.

    Read the article

  • When upgrading from Vista to Windows 7 on a DELL laptop, how do I know which drivers to reinstall an

    - by msorens
    According to Dell's upgrade page for Vista to Windows 7, after using the upgrade assistant the final step is to install drivers. They refer to this page for the order of driver installation, listing 9 items. From there I go to the Dell Drivers and Downloads page, enter my system tag, and get a list of the downloads available for my specific box. That page, by the way, has a link to driver install instructions that lists 10 rather than 9 items. Going to Drivers Help in the side panel and clicking on "In what order should drivers be installed?" shows yet a third list, this one containing 13 items. Not surprisingly, the order of these 3 lists of drivers are not quite the same for the common items! Furthermore, of the 26 files Dell's site recommends for my machine, there are several not shown on any of the 3 lists! I can make determinations for some of these: 6 of them are "applications" so I know which of those I want and that they could probably be safely installed after all drivers. BIOS: I would think this should be unaffected by an OS upgrade so could be skipped. Two tools in the diagnostics category: could probably be done after all drivers. That leaves just a CD/DVD driver and a webcam driver unaccounted for. So my two related questions are these: How critical is the driver installation order and which one do I follow? (Keep in mind this is for an upgrade, not a fresh install.) Where in the order do I insert the CD/DVD and the webcam drivers (if needed) ? Dell's driver download page provides (in theory) the list of all downloads relevant to my specific machine, via the service tag. But do I actually need to reinstall all of them? some? none? How does one determine this? They do label each with Recommended or Optional, so do I need to reinstall all the recommended ones? (Part of the reason for my perplexed frown is that I wonder why I would need to reinstall a CD/DVD driver since I would already be using the drive to install the OS!)

    Read the article

  • Tool or script to detect moved or renamed files on Linux prior to a backup

    - by Pharaun
    Basically I am searching to see if there exists a tool or script that can detect moved or renamed files so that I can get a list of renamed/moved files and apply the same operation on the other end of the network to conserve on bandwidth. Basically disk storage is cheap but bandwidth isn't, and the problem is that the files often will be reorganized or moved around into a better directory structure thus when you use rsync to do the backup, rsync won't notice that its a renamed or moved file and re-transmission it over the network all over again despite having the same file on the other end. So I am wondering if there exists a script or tool that can record where all the files are and their names, then just prior to a backup, it would rescan and detect moved or renamed files, then I can take that list and re-apply the move/rename operation on the other side. Here's a list of the "general" features of the files: Large unchanging files They can be renamed or moved around [Edit:] These all are good answers, and what I end up doing in the end was looking at all of the answers and will be writing some code to deal with this. Basically what I am thinking/working on now is: Using something like AIDE for the "initial" scan and enable me to keep checksums on the files because they are supposed to never change, so it would aid on detecting corruption. Creating an inotify daemon that would monitor these files/directory and recording any changes relating to renames & moving the files around to a log file. There are some edge cases where inotify might fail to record that something happened to the file system, thus there is a final step of using find to search the file system for files that has a change time latter than the last backup. This has several benefits: Checksums/etc from AIDE to be able to check/make sure that some media did not get corrupt Inotify keeps resource usage low and no need to re-scan the filesystem over and over No need to patch rsync; If I have to patch things I can, but I would prefer to avoid patching things to keep the burden lower, (IE don't need to re-patch everytime there is an update). I've used Unison before and its really nice, however I could've sworn that Unison does keep copies around on the filesystem and that its "archive" files can grow to be rather large?

    Read the article

  • Data capture from other sheet into Summary sheet

    - by Hemant
    an Excel workbook which has Summary sheet, Pending and Master Sheet. My requirement is below and try to develop a Macro or VB logic for excel • I want to control this workbook from Summary sheet. o Generate Fault Summary – ? I have set logic but if doesn’t give warning if sheet name is exists , so need to add this logic . ? When we press the Fault Report Summary command button then it copy the master sheet with cell “A6” Name and will hide the Master sheet. Again when you select the another Month name then it will generate the sheet for that month name. o Generate Toll System Uptime ? When I select the sheet name and “Week” then Press the “Enter “Command button then it should get the result from that sheet number . Each sheet number has Month detail in B2 Cell. ? To calculate the Uptime formula for Week wise is • Week-01 = (1680-SUMIFS(L5:L23,B5:B23,"="&B2,B5:B23,"<="&(B2+6)))/1680 • Week-02 =(1680-SUMIFS(L5:L23,B5:B23,"="&(B2+7),B5:B23,"<="&(B2+13)))/1680 • Week-03 =(1680-SUMIFS(L5:L23,B5:B23,"="&(B2+14),B5:B23,"<="&(B2+20)))/1680 • Week-04 =(1680-SUMIFS(L5:L23,B5:B23,"="&(B2+21),B5:B23,"<="&(B2+27)))/1680 • Month =(1680-SUMIFS(L5:L23,B5:B23,"="&(B2),B5:B23,"<="&(DATE(YEAR(B2),1+MONTH(B2),1)-1)))/1680 ? Result should reflect in Summary sheet at B18 cell . o Pending Fault Report Summary ? When segregate the report on its status like which one is open or Close . It is open then it is Pending Fault Report and when it is Close status it means it is closed. ? If any fault which has OPEN status in all sheets(Jan-13,Feb-13,Mar-13….etc) then it should be come as well as in Pending Sheet which ascending date order. ? When it’s status is changed then it should be moved in that month sheet or nearby fault created date. It status is close then it should not be available in pending sheet as it’s status is Closed. ? Each fault has Reported date and we monitor all fault according reported date. ? When we press the Update Fault Report Summary command button then it should update as above logic. ? Some time we export the Pending fault report , so date calendar should be present in Start and End date to Choose the date. When we press the Export command line then it should export the Pending fault report and able to save in Excel,PDF.

    Read the article

  • Windows7 issue in mutli- tasking and memory

    - by Nitesh
    I seeming some problem in my windows OS recently, let me first say my system configuration. processor - Intel(R) Core(TM)2 Quad CPU Q8400 @ 2.66 GHz Installed memory (RAM) - 4.00 GB (3.00 GB usable) System type - 32 bit operating system I am using two OS in this system, first one is Windows7 and the other is centOS. Well, I am using this from a long time there was no problem , and all of a sudden since from couple weeks I am facing problems in my Windows7 OS. In windows7 i was nearing using multiple jobs almost every time i log in, there was no problem but now i don't no what happen I am not able to do multiple jobs at same time. For example- 1 I am now not able to listen to music in windows media player and view photo's. All of a sudden the system stops working and does not respond and then respond after 5mins and the music get played where it got stopped after 5 mins. 2 When i start browersing internet it hangs all of sudden and doesn't respond for 2 or 3 mins and gets loading. I mean it just happens for every operation i do in the system. Even now typing was also difficult, it gets hanged very frequently even though i am doing single task. I have never come across this kind of problem before. So the first thing i did was to see the useage of the processor and the memory. Well, i thick the useage of the processor was fine, for single task the useage was some where around 3 to 5%. Well, it was something weird i found in the memory, in spite of no task that i was running it was using somewhere around 34 to 41% of memory. So i opened the task manager and click on resource monitor in performance tab. And in the memory section of the monitoring tool i found the usage of my RAM, it was something like this. Hardware reserved - 1029 MB In Use - 1430 MB Modified - 49 MB Standby - 1566 MB free - 22 MB And i could also see Available 1588 MB Cached 1615 MB Total 3067 MB Installed 4096 MB well, this if all i could find out and i have no idea why my computer is acting so weird all of a sudden and the performance problem is growing day by day and i also don't know if there is problem in Bios, i have let it for default settings from long time. please help me and Thank you in advance for reading this and helping me.

    Read the article

  • System failure - need diagnostic recommendation

    - by Ladislav Mrnka
    I have big problem with my computer. Configuration is: Intel i7 + 6x2GB OCZ DDR3 Motheboard: Asus P6T Deluxe V2, HDD controller configured to AHCI Main drive: OCZ Vertex 2 (SSD) - contains all installed programs and system Second drive: Samsung SpinPoint - contains User profiles, ProgramData, virtual machines and databases Third drive: Samsung SpinPoint - data drive + backups OS: Windows 7 Ultimate x64 I have never had any problem with this computer until now. During weekend my computer completely crashed without any reason. Each time I tried to boot to Windows I got BSOD with message BAD_SYSTEM_CONFIG_INFO and automatic restart (I didn't install any new SW or HW). But after restart main OCZ drive was disconnected (not detected by BIOS). When I turned off and on computer, the drive was again connected. It also happend every single time I tried to repair installation somehow. It ended with some error and after restart drive was disconnected. The only thing which worked was format + fresh install. After installing almost everything I wanted to install Visual Studio 2010 Ultimate (complete installation without SQL Server Express). During installation of VS itself I always get BSOD - it is too fast so I'm not able to read description. After restart it searches for all disk drives for really long time and sometimes it changes boot drive so the system is not able to start - Bootmgr not found. After reconfiguring BIOS the system starts. There is no event describing the failure in Event viewer. Installing VS 2010 is absolutely necessary for me. I need help with diagnostic. I need to find where is the problem - I expect that the problem is in OCZ drive or in HDD controller on motherboard but I don't know how to find it. All components still have valid warranty. Can you recommend me some approach or tools to find the problem? Edit: I'm still looking for source of the problem. New information is that Windows are not able to perform check disk (Chkdsk) on the SSD system drive. After restarting it always starts checking drive and in part where files are checked it fails with BSOD - BAD_SYSTEM_CONFIG_INFO. After next restart and skipping check disk tests the system runs.

    Read the article

  • Got Hacked. Want to understand how.

    - by gaoshan88
    Someone has, for the second time, appended a chunk of javascript to a site I help run. This javascript hijacks Google adsense, inserting their own account number, and sticking ads all over. The code is always appended, always in one specific directory (one used by a third party ad program), affects a number of files in a number of directories inside this one ad dir (20 or so) and is inserted at roughly the same overnight time. The adsense account belongs to a Chinese website (located in a town not an hour from where I will be in China next month. Maybe I should go bust heads... kidding, sort of), btw... here is the info on the site: http://serversiders.com/fhr.com.cn So, how could they append text to these files? Is it related to the permissions set on the files (ranging from 755 to 644)? To the webserver user (it's on MediaTemple so it should be secure, yes?)? I mean, if you have a file that has permissions set to 777 I still can't just add code to it at will... how might they be doing this? Here is a sample of the actual code for your viewing pleasure (and as you can see... not much to it. The real trick is how they got it in there): <script type="text/javascript"><!-- google_ad_client = "pub-5465156513898836"; /* 728x90_as */ google_ad_slot = "4840387765"; google_ad_width = 728; google_ad_height = 90; //--> </script> <script type="text/javascript" src="http://pagead2.googlesyndication.com/pagead/show_ads.js"> </script> Since a number of folks have mentioned it, here is what I have checked (and by checked I mean I looked around the time the files were modified for any weirdness and I grepped the files for POST statements and directory traversals: access_log (nothing around the time except normal (i.e. excessive) msn bot traffic) error_log (nothing but the usual file does not exist errors for innocuous looking files) ssl_log (nothing but the usual) messages_log (no FTP access in here except for me)

    Read the article

  • Start a software company offshore

    - by Mascarpone
    Hello Everybody, I own a small, very young, EU based (Italy) company, and among other things, we sell IT solutions. I have a degree in applied mathematics, and I mainly deal with user interfaces, embedded systems, automation and web applications. You can say that I'm an enlightened entrepreneur because I work only with open source software (OS, IDE, I release under BSD , ... everything is free as in freedom), I give high importance to post sales services and customer satisfaction, plus I think I'm the best boss someone could desire (LOL), as I have google in mind when I think about IT workers rights. But the most beautiful thing is that, although everybody advised us not to use open source, is that we are quite profitable!!! (for the sixth trimester in a row). Now I offshore most of the work to an Indian company. I divide the work in modules and I outsource the longer or more trivial ones. I spend a lot of time defining the specifications and I leave the hard work to them. Using productivity bonuses, a lot of prototypes and third-party audits I think that my software has reached a very good quality level. I would like to start my own software development company, in order to improve control over process and cut costs. Obviously I can't afford the cost of labor in the EU, so I thought about opening a company in Asia. What I need Is: 1) Cheap labor - I can afford to give productivity bonuses and higher than average wages and stay profitable just because labor is cheap. 2) Many talents - I need a good level of tertiary education, and a good number of graduates, so I can hire junior developers and train and teach them according to my needs and philosophies (e.g.: open source mind) 3) Good infrastructure - buildings, transport, internet, .... everything that a company might need. I thought about 3 possible candidates: 1) India - I already work with indian people, I know that they are realiable and speak a good english. Big cities are too expensive, but maybe a small city like lucknow http://en.wikipedia.org/wiki/Lucknow could suits my needs. 2) China - They say it's cheaper than India, but I everytime I worked with a chineese company the language was a big barrier. They work hard, are somewhat skilled and cheap but maybe it's a risky path. Plus I feel a little uncofortable with their lack of human rights. 3) Philippines - Same as china: cheaper than india, but maybe less educated. Where do you think it's the best place to start a software company? Any reading or book to advise? thank you very much

    Read the article

  • ssh client problem: Connection reset by peer

    - by yonix
    I'm having a really annoying problem on my Ubuntu laptop. I noticed it today, after upgrading to Ubuntu 11.04, although I'm not entirely sure this is the cause as I played with my ssh keys a few days ago. The problem is, whenever I try to ssh to ANY host I get the following error: Read from socket failed: Connection reset by peer running with -vvv gives the following output: OpenSSH_5.8p1 Debian-1ubuntu3, OpenSSL 0.9.8o 01 Jun 2010 debug1: Reading configuration data /etc/ssh/ssh_config debug1: Applying options for * debug2: ssh_connect: needpriv 0 debug1: Connecting to hostname [10.0.0.2] port 22. debug1: Connection established. debug1: permanently_set_uid: 0/0 debug1: identity file /root/.ssh/id_rsa type -1 debug1: identity file /root/.ssh/id_rsa-cert type -1 debug1: identity file /root/.ssh/id_dsa type -1 debug1: identity file /root/.ssh/id_dsa-cert type -1 debug1: identity file /root/.ssh/id_ecdsa type -1 debug1: identity file /root/.ssh/id_ecdsa-cert type -1 debug1: Remote protocol version 1.99, remote software version OpenSSH_4.2 debug1: match: OpenSSH_4.2 pat OpenSSH_4* debug1: Enabling compatibility mode for protocol 2.0 debug1: Local version string SSH-2.0-OpenSSH_5.8p1 Debian-1ubuntu3 debug2: fd 3 setting O_NONBLOCK debug3: load_hostkeys: loading entries for host "hostname" from file "/root/.ssh/known_hosts" debug3: load_hostkeys: loaded 0 keys debug1: SSH2_MSG_KEXINIT sent Read from socket failed: Connection reset by peer My /etc/ssh/ssh_config: Host * SendEnv LANG LC_* HashKnownHosts yes GSSAPIAuthentication no GSSAPIDelegateCredentials no I can connect to my laptop from any other server via ssh, and I can also ssh localhost from my laptop successfully. I can connect to all these other server from other laptops, and I don't see anything in the logs of the other servers regarding my failed attempt. I tried to stop iptables, didn't help. I tried several tricks I could find online with my /etc/ssh/ssh_config, but I was unsuccessful in solving the problem... Any ideas? Edit: This is the log from one of the hosts I try to connect to: May 1 19:15:23 localhost sshd[2845]: debug1: Forked child 2847. May 1 19:15:23 localhost sshd[2845]: debug3: send_rexec_state: entering fd = 8 config len 577 May 1 19:15:23 localhost sshd[2845]: debug3: ssh_msg_send: type 0 May 1 19:15:23 localhost sshd[2845]: debug3: send_rexec_state: done May 1 19:15:23 localhost sshd[2847]: debug1: rexec start in 5 out 5 newsock 5 pipe 7 sock 8 May 1 19:15:23 localhost sshd[2847]: debug1: inetd sockets after dupping: 3, 3 May 1 19:15:23 localhost sshd[2847]: Connection from 10.0.0.7 port 55747 May 1 19:15:23 localhost sshd[2847]: debug1: Client protocol version 2.0; client software version OpenSSH_5.8p1 Debian-1ubuntu3 May 1 19:15:23 localhost sshd[2847]: debug1: match: OpenSSH_5.8p1 Debian-1ubuntu3 pat OpenSSH* May 1 19:15:23 localhost sshd[2847]: debug1: Enabling compatibility mode for protocol 2.0 May 1 19:15:23 localhost sshd[2847]: debug1: Local version string SSH-2.0-OpenSSH_5.3 May 1 19:15:23 localhost sshd[2847]: debug2: fd 3 setting O_NONBLOCK May 1 19:15:23 localhost sshd[2847]: debug2: Network child is on pid 2848 May 1 19:15:23 localhost sshd[2847]: debug3: preauth child monitor started May 1 19:15:23 localhost sshd[2847]: debug3: mm_request_receive entering May 1 19:15:23 localhost sshd[2848]: debug3: privsep user:group 74:74 May 1 19:15:23 localhost sshd[2848]: debug1: permanently_set_uid: 74/74 May 1 19:15:23 localhost sshd[2848]: debug1: list_hostkey_types: ssh-rsa,ssh-dss May 1 19:15:23 localhost sshd[2848]: debug1: SSH2_MSG_KEXINIT sent May 1 19:15:23 localhost sshd[2848]: debug3: Wrote 784 bytes for a total of 805 May 1 19:15:23 localhost sshd[2848]: fatal: Read from socket failed: Connection reset by peer

    Read the article

  • Network switching issues with MacOS 10.7?

    - by Denis
    I'm having a wired problem and hope somebody can tip me, what way should I dig to. I'm using MacBookPro with Lion 10.7.3 both at my working place & at home. At working place, we have a domain-based network with 802.1x authorization (more than 400 computers) and to connect it I'm using Ethernet cable. IP range is 10.10.2.*. All network settings are setup automatically by DHCP. Also, in settings, I have Network Account Server setup in the User&Groups Settings for my work Domain server - and it is available only from corporate network. At home, I have an ADSL router, that shares Internet connection by WiFi in NAT mode. I'm using WiFi to connect it. Router gives out addresses from 192.168.1.* range and all settings are also set up by router's DHCP. So, my problem is the following. When I come back home from the office, I open my MacBook and AirPort automatically connects my WiFi network. After this, for about 1 minute I'm able to browse sites & ping hosts successfully. But after this minute, network connection is broken down. All pings return time-out. trace route to google.com stops on 192.168.1.1 (which is my router). This lasts for 3-4 minutes. After that network connection is automatically repaired and all pings go smoothly again. At the same time, when my MacBook return timeouts, I can successfully ping any host from my wife's MacBook - so this doesn't look like router issue. When I come to the office, I don't have any issues and Internet connection is available & stable moments after ethernet cable plugged in. Do anybody has any clues about this? What should I monitor & what settings look for resolving this issue? Please, ask, what additional information should I provide. Hoping for good advice & thanks in advance!

    Read the article

  • System won't boot: Gigabyte HD 7790 1GB OC GPU issue or Corsair VS550 PSU issue?

    - by MGOwen
    Installed a new GPU, and PC won't boot. Turn it on and: No monitor signal at all (tried HDMI and VGA via DVI, on 2 working monitors). CPU and GPU fans DO spin, but No system beeps, no sounds from drives (they might make a small noise in the first 1 second or so, but there's definitely no OS loading or anything like that) If hit "power off" button it turns off immediately (no holding down for 3 seconds like usual) If I put my old HD 5670 GPU back in, everything works fine. But (plot twist!) card is not totally dead. My friend put it in his PC, and it works fine (he even played a game for 15 minutes, no issues). He has a Corsair TX850 850W and a Gigabyte MB. So my main theory is: the GPU isn't getting enough power from the PSU. But is it: Bad PSU? Seems unlikely, since it works fine with the other GPU. Also, the PSU Is brand new and 550W (single 42A/504W 12V rail). Overkill for this GPU. Corsair is a decent brand, but maybe just mine is faulty? Bad GPU? Could it be drawing more power than it should be, somehow, or something? Supposedly HD 7790 needs only 21A/75W on the 12v rail, though this one is factory overclocked a bit... but should that triple the power requirement? Something else? Could there be a motherboard incompatibility somehow? Both MB and GPU are less than a year old and PCI Express 3.0 x16. Things I've tried: Re-seating the video card Testing PC with old GPU (works fine, same PCIe slot). Checked AMD's stated amp/watt requirements of a 7790 and my PSU (see above). My PSU can output twice the amps (single rail) and 5x the Wattage a 7790 needs. Here are the full specs: Gigabyte HD 7790 1GB OC GPU Corsair VS550 550W PSU 4GB RAM AsRock H61M U3S3 motherboard i3-2100 500GB SATA HDD (2007-ish) blu-ray drive (new) PCI 802.11g card Edit: Motherboard BIOS Update seems to have fixed it. (If anyone has same problem and it doesn't work, comment here).

    Read the article

  • Some Memory Slots Not Working on MSI FM2-A85XA-G65 Motherboard

    - by Mike Ciaraldi
    Short version of question: Does anyone have an MSI FM2-A85XA-G65 motherboard, who can confirm that all four memory slots work? Long version: Several months ago I bought an MSI FM2-A85XA-G65 motherboard at Newegg. At that point I installed an AMD A8-5500 processor and two sticks of Corsair Vengeance 8 GB DDR3-1866 memory, and put it into my file server. I installed the RAM in slots 1 and 3, as directed in the manual, to enable dual-channel memory access. It seemed to work fine, so I bought a second identical mobo (which arrived dead, but was quickly replaced by Newegg) and set of RAM, installed an A10-5800K, and put that into my production Linux machine. Again, it seemed to work well. Eventually I happened to notice that on the server only 8 GB of RAM appeared in the BIOS. I tried each of the slots and memory modules individually and in various combinations. I even swapped processors with the production machine. The result was that putting memory in slots 1 and 2 worked (showing a total of 16 GB), but any memory in slots 3 or 4 was not recognized. However, all four memory slots in the production machine worked, and I confirmed this with both processors. I contacted MSI and arranged to ship the defective mobo back to them for replacement under warranty. I did not want my file server to be down in the interim, and I had another machine I wanted to upgrade, so I bought a third identical mobo to use. That one had the same problem -- only memory slots 1 and 2 worked. I tested it thoroughly with multiple processors and memory sticks. I sent the defective mobo back to MSI and they sent me a new one. This has the same memory slot problem. So I sent it back. The replacement arrived the other day and shows the same problem. I contacted MSI yet again and they said that nobody else has reported memory slot problems on this board and it must be my processor. So my score so far is, out of six boards of this model, I have: One where all four slots work. One which was dead on arrival. Four where only memory slots 1 and 2 work. Before I tear my other machines apart and start swapping processors again I thought I would ask if anyone else has this exact model motherboard and could confirm that all four memory slots either do or do not work. According to MSI you should be able to just plug a single memory module into any of the slots and it will work (and it does on the one mobo I have which works correctly). If you have not yet used all four slots, this is a good time to test them so you know if you can expand your memory in the future. Thanks in advance to anyone who can help.

    Read the article

  • Share the same subnet between Internal network and VPN Clients

    - by Pascal
    I would like to set up a configuration where VPN clients connecting to my Forefront TMG can access all the resources of my Internal network without having the to use the option "Use default gateway on remote network" on the VPN's TCP/IP Ipv4 Advanced Settings. This is important to me, since they can use their own internet while accessing my network through VPN (the security implications of this are acceptable on my cenario) My Internal network runs on 10.50.75.x, and I set up Forefront TMG to relay the DHCP of my Internal network to the VPN clients, so they get IPs from the same range as the Internal network. This setup initially works, and the VPN clients use their own internet, and can access anything that is on the internal network. However, after a while, HTTP Proxy Traffic from the Internal network starts getting routed to the IP of the RRAS Dial In Interface, instead of the IP of the Internal's network gateway. When this happens, the HTTP Proxy starts getting denied for obvious reasons. My first question is: does this happen because Forefront TMG wasn't designed to handle a cenario that I described above, and it "loses itself"? My second question is: Is there any way to solve this problem, either through configuration or firewall policies? My third question is: If there's no way that it can work with the cenario above, is there another cenario that will solve my problem, and do what I'd like it to do properly? Below are my network routes: 1 => Local Host Access => Route => Local Host => All Networks 2 => VPN Clients to Internal Network => Route => VPN Clients => Internal 3 => Internet Access => NAT => Internal, Perimeter, VPN Clients => External 4 => Internal to Perimeter => Route => Internal, VPN Clients => Perimeter Tks!

    Read the article

  • Windows 8 disk errors

    - by wrongusername
    So yesterday, I forcibly restarted my Windows 8 PC. VMWare Workstation was having some trouble with the guest Linux Mint OS. It wasn't responding for some time, so I tried suspending it September 28th or perhaps even before. It wouldn't suspend -- I forgot what the window looked like, but all options in the power menu were disabled (i.e. "Shutdown," "Power Off," and options like that were all disabled). I eventually killed the VMWare application through Task Manager, though I was too lazy to hunt down the running virtual machine itself, and decided to kill it by just shutting down my PC entirely. The PC wouldn't shut down for quite some time after the monitor went blank, so I did a cold reset by holding the power button. I then powered it on again and Windows briefly gave me some message like "Search for KERNEL_STACK_INPAGE_ERROR." Windows then started diagnosing some problems and gave me the message, "Repairing disk errors. This might take over an hour to complete." That was yesterday night, and I went to sleep without waiting for it to finish. This morning, it said that the repair failed, and that the log was at C:\windows\system32\LogFiles\srt\srtTrail.txt (as I remember it -- I don't have the exact path I wrote down right now). It gave me some other options to troubleshoot, such as resetting Windows (files and settings still intact, but programs not installed through the app store will be erased). That didn't work (no error message given, I was just told it didn't work). I tried rebooting in safe mode, the same diagnosis process begins, except that this time it doesn't bother with the automatic repairs again. So I tried using the command prompt to try to see if my files are at least still there. I was on the X drive, and I couldn't cd to the C drive. I couldn't find my folder under Users (of course?), and couldn't find the srt folder under LogFiles either. I am not sure what to try next. I have backed up everything, but to the cloud, so if absolutely necessary I can start off with a fresh copy of Windows and restore all my data, though it would be a hassle. Any thoughts on what might be wrong or what I can try? My computer was purchased just this June, so the hard drive should still be pretty new.

    Read the article

  • VirtualBox Port Forward not working when Guest IP *IS* specified (while doc says opposite)

    - by Patrick
    Trying to port forward from host (Mac OS X) 127.0.0.1:8282 - guest (CentOS)'s 10.10.10.10:8080. Existing port forwards include 127.0.0.1:8181 and 9191 to guest without any IP specified (so whatever it gets through DHCP, as explained in the documentation). Here is how the non-working binding was added: VBoxManage modifyvm "VM name" --natpf1 "rule3,tcp,127.0.0.1,8282,10.10.10.10,8080" Here is how the working ones were added: VBoxManage modifyvm "VM name" --natpf1 "rule1,tcp,127.0.0.1,8181,,80" VBoxManage modifyvm "VM name" --natpf1 "rule2,tcp,127.0.0.1,9191,,9090" And by "non-working", I of course mean not listening (as a prerequisite to forwarding): $ lsof -Pi -n|grep Virtual|grep LISTEN VirtualBo 27050 user 21u IPv4 0x2bbdc68fd363175d 0t0 TCP 127.0.0.1:9191 (LISTEN) VirtualBo 27050 user 22u IPv4 0x2bbdc68fd0e0af75 0t0 TCP 127.0.0.1:8181 (LISTEN) There should be a similar line above but with 127.0.0.1:8282. Just to be clear, this port is listening perfectly fine on the guest itself. And when I remove the guest IP (i.e., clear the 10.10.10.10) the forward works fine, albeit to eth0 (not eth1 where I need it). I can tcpdump and watch the traffic flow back and forth. And yes, I've disabled iptables entirely while testing -- it's not getting blocked anywhere on the guest. As VirtualBox writes in their documentation, you are required to specify the guest IP if it's static (makes sense, no DHCP record it keeps): "If for some reason the guest uses a static assigned IP address not leased from the built-in DHCP server, it is required to specify the guest IP when registering the forwarding rule:". However, doing so (as I need to), seems to break the port forward with nary a report in any log file I can find. (I've reviewed everything in ~/Library/VirtualBox/). Other notes: While I used the above command to add the third rule, I've also verified it showed up correctly in GUI and then removed/re-added from there just to make sure). This forum link -- while very dated -- looks somewhat related in that a port forward to a static IP was not appearing (perhaps they think due to lack of gratuitous arp being sent for host to know IP is there/avail?). Anyway, what gives? Is this still buggy? Any suggestions? If not, easy enough workarounds? What's interesting is that this works perfectly fine on another user's Mac, however he's running a slightly older version (4.3.6 v. 4.3.12).

    Read the article

  • Melting Laptop Power Supply Tip

    - by AlReece45
    Several (6-7) months ago, my laptop power supply cord got a cut in it and stopped working. Having gotten cheap (and short) power supplies in the past, I decided to buy 2 brand new ones from the manufacturer (ASUS). Now, I used my laptop a little less than usual between February and March. During that time I noticed a few times that the power supply, even though plugged in, did not provide power. Often the computer would just off on me. I figured it was just that one power supply being bad. I had left the alternate at my parent's house in another state and asked them to ship it to me. Now, at work the other day I wanted to get a file off the of hard disk. So I booted it up, knowing that it had a low battery, plugged it in. During the first 2 minutes of use, I was told that the battery was low and I should plug it in. I unplugged it, inspected the end (Being plugged in, this was suspicious), and decided I shouldn't plug it back in-- the plastic on the tip was melting from the heat of the metal on the tip. The computer had simply booted up and I had the file-manager open. It had not been on for more than 10 hours. Now I know that computers tend to get pretty hot. However, the melting point of plastic is usually above 200C.. so that's much hotter than the computer should be generating. I went and bought a THIRD power supply. This time a universal one from Best Buy (it was very fast to buy and test). I tried it out on the computer and it's tip is melting as well. My older laptop that uses the universal power supply uses it perfectly (has been about a week and a part of use now). I have tried using the computer without the battery, with the same effect. Obviously, this is not a problem with the power supply. My room mate and I being trained computer techs were contemplating taking the computer apart and desoldering and resoldering on the power tip. (The computer is about 6 months out of its 2-year warranty). We're hoping that will correct the issue as I would prefer to devote my money on a Good Desktop rather than yet ANOTHER $1200+ laptop. Is there any thing I'm missing here that might cause the the tip on the power unit to melt?

    Read the article

  • Complete machine freezes...at a loss

    - by user28818
    Guys, We built around 12 machines a few months ago to run Ubuntu. They each have the following specs: ASUS Z8NA-D6 motherboard Dual quad core Intel(R) Xeon(R) CPU E5520 @ 2.27GHz OCZ Mod Extreme Pro 500W power supply 12 GB Kingston RAM Nvidia GeForce 9800 GT graphics card My machine ran well for awhile. However, it started experiencing random lockups. These lockups are not X lockups, they are complete system freezes. The nic stops responding, the magic sysrq buttons won't work. The machine is dead. I first suspected RAM. Memtest86 didn't find anything, but I replaced the RAM anyway. Still, lockups. So I replaced the graphics card. Still, more lockups. They became more and more frequent and started to happen 2-3 times a day. So I replaced the motherboard and power supply in one fell swoop. Suddenly, no more lockups! Woohoo! Except, a week later, in the morning, the machine wouldn't wake up. I reset it, started it up, and the log files showed the last entry at around 11 pm the evening before. This has started occurring with more frequency...now just about every morning I come in, the machine is locked up, and has been since the night before. Yesterday, in the 3 weeks since I replaced the motherboard and power supply, the machine actually locked up on in in mid-work. This is the first time since replacing the two (MB and PS) that this happened while I was using it. All others occurred while I was away. I'm at a loss. Nothing is in syslog or message that would indicate a problem around the time of the lockup. Temps are good...I use lmsensors to monitor and have a script that writes the output to file every minute. They never get that high. The only thing I haven't replaced at this point is the case and the harddrives. I doubt either could be the cause. What would you do if you were in my shoes? Is there a troubleshooting approach I'm missing? For the record, all of the other machines, all eleven of them, don't have any problems. They're all running the same version of Ubuntu (Lucid) that I am. Thanks!

    Read the article

  • Low FPS in some games, but hardware not fully used

    - by Mario De Schaepmeester
    I just did a little funny experiment in the game/sim "Train Simulator 2013". I normally have good FPS in it (around 30) at full settings. What I did was make a really, really long train so that the calculations the sim needed to make were enormous (the sim is quite realistic, it takes all things into account like speed/acceleration, G-forces, comfort levels, possible wheel slip and many more, and most of those things on each carriage seperately). This resulted in only 14FPS as reported by the game, but it felt more like 8FPS or so. I have a Logitech G15 keyboard which has an LCD, and it allows me to monitor CPU/RAM and video card load on it. The strange thing is, all CPU cores were busy, but the total load was only about 60% maximum at all times. The video card was only on 30% load (possibly an important note, the memory was full, which is however not unusual for the game in question). The RAM had plenty of room and there weren't many operations as it didn't grow or shrink much. I just have the feeling that the game would run smoother if it used more of my hardware power. Why is it not doing so? I had the same in another game, The Elder Scrolls: Morrowind when using more than 100 mods (that all use scripting) and a few high res texture mods, + a full-on graphics improvement program. The engine is very old (2003), and so I thought this might be the cause (not being optimised for multithreading). I had thought of possible causes, like: The operating system doesn't let the games use all the resources. It doesn't make use of multi-threading appropriately. To eliminate the former, I tried a CPU stress tool and that got 100% CPU juice as I let it run, so the OS is not the problem. I gave its thread the "higher" priority though. My actual question In both games, I did things the engine was not really built to do or support. Can those games' framerate be limited cause of their own engine not being able to cope? What is the real reason and more importantly, can I help it? And in any case, could something actually be wrong with my hardware? It's all reasonably new, a couple of months, and I (almost) never experience any other trouble. Modern and much more demanding games work absolutely fine. Specs CPU: AMD Phenom II 965 X4 @ 3.4gHz RAM: 8GB of DDR3 RAM Video: MSI GTX560 (nVidia chip) with 1GB of GDDR5 memory OS: Windows 7 Ultimate 64 bit Nothing overclocked.

    Read the article

  • If Nvidia Shield can stream a game via wifi, why can I not do the same via ethernet to any other PC?

    - by Enigma
    I think it absurd that a wireless game streaming solution is the *first to hit the market when a 1000mbps+ Ethernet connection would accomplish the same feat with roughly 6x the available bandwidth. I can only assume that there must be some reason behind this or a limitation preventing this, but what? 150mbps wifi is in no way superior to a 1000mbps LAN connection aside from well wireless mobility. Not only that but I have a secondary laptop and desktop which should by hardware comparison completely outperform anything the Tegra in the Nvidia Shield can do. Is this all just a marketing scheme to force people to buy the shield for the streaming benefit? Chief among these is that NVIDIA’s Shield handheld game console will be getting a microconsole-like mode, dubbed “Shield Console Mode”, that will allow the handheld to be converted into a more traditional TV-connected console. In console mode Shield can be controlled with a Bluetooth controller, and in accordance with the higher resolution of TVs will accept 1080p game streaming from a suitably equipped PC, versus 720p in handheld mode. With that said 1080p streaming will require additional bandwidth, and while 720p can be done over WiFi NVIDIA will be requiring a hardline GigE connection for 1080p streaming (note that Shield doesn’t have Ethernet, so this is presumably being done over USB). Streaming aside, in console mode Shield will also support its traditional local gaming/application functionality. - http://www.anandtech.com/show/7435/nvidia-consolidates-game-streaming-tech-under-gamestream-brand-announces-shield-console-mode ^ This is not acceptable for me for a number of reasons not to mention the ridiculousness of having a little screen+controller unit sitting there while using a secondary controller and screen instead. That kind of redundant absurdity exemplifies how wrong of a solution that is. They need a second product for this solution without the screen or controller for it to make sense... at which point your just buying a little computer that does what most other larger computers do better. All that is required, by my understanding, is the ability to decode H.264 video compression and transmit control/feedback so by any logical comparison, one (Nvidia especially) should have no difficulty in creating an application for PC's (win32/64 environment) that does the exact same thing their android app does. I have 2 video cards capable of streaming (encoding) H.264 so by right they must be capable of decoding it I would think. I haven't found anything stating plans to allow non-shield owners to do this. Can a third party create this software or does it hinge on some limitation that only Nvidia can overcome? (*) - perhaps this isn't the first but afaik it is the first complete package.

    Read the article

  • Create and manage child name servers (glue records) within my domain?

    - by basilmir
    Preface I use a top level domain provider that only allows me to add "normal" third-party name servers (a list where i can add "ns1.hostingcompany.com" type entries... nothing else) AND "child name servers" which i can later attach to my parent account ( ns1.myowndomain.com and an ip address). They do not provide other means of linking up. I want to host my own server and dns, even with just one name server (at first). My setup: Airport Extreme - get's a static ip address from my ISP Mac Mini Server - sits behind the Airport and get's a 10.0.1.2 My problem is that i can't seem to configure DNS correctly. I added a "child nameserver" with my airport's external static ip address at the top level provider, so to my understanding i should have all DNS traffic redirected to my Airport. I've opened port 53 UDP to let the traffic in. Now, what i don't get is this. My Mini Server is sitting on a 10.0.1.2 address and i have setup dns correctly, with an A record to point and resolve my server AND a reverse lookup to that 10.0.1.2. So it's ok for "internal stuff". Here is the clicker... How, when a request comes from the exterior for a reverse lookup, does the server "know" ... well look i have everything in 10.0.1.2 but the guy outside needs something from my real address. I can't begin to describe the MX record bonanza... How do i set this "right"? Do i "need" my Mini Server to sit on the external address directly (i can see how this could be the preferred solution, being close to a "real" server i have in my mind). If not... do i need a PTR record on the 10.0.1.2 server but with the external address in there? My dream: I will extend this "setup" with multiple Mini's in different cities where i work. I want a distributed something (Xgrid comes to mind). PS. Be gentle, i've read 2 books and the subject, and bought both the Lynda Essentials and DNS and Networking to boot, still i'm far from being on top of things.

    Read the article

  • How to reliably map vSphere disks <-> Linux devices

    - by brianmcgee
    Task at hand After a virtual disk has been added to a Linux VM on vSphere 5, we need to identify the disks in order to automate the LVM storage provision. The virtual disks may reside on different datastores (e.g. sas or flash) and although they may be of the same size, their speed may vary. So I need a method to map the vSphere disks to Linux devices. Ideas Through the vSphere API, I am able to get the device info: Data Object Type: VirtualDiskFlatVer2BackingInfo Parent Managed Object ID: vm-230 Property Path: config.hardware.device[2000].backing Properties Name Type Value ChangeId string Unset contentId string "d58ec8c12486ea55c6f6d913642e1801" datastore ManagedObjectReference:Datastore datastore-216 (W5-CFAS012-Hybrid-CL20-004) deltaDiskFormat string "redoLogFormat" deltaGrainSize int Unset digestEnabled boolean false diskMode string "persistent" dynamicProperty DynamicProperty[] Unset dynamicType string Unset eagerlyScrub boolean Unset fileName string "[W5-CFAS012-Hybrid-CL20-004] l****9-000001.vmdk" parent VirtualDiskFlatVer2BackingInfo parent split boolean false thinProvisioned boolean false uuid string "6000C295-ab45-704e-9497-b25d2ba8dc00" writeThrough boolean false And on Linux I may read the uuid strings: [root@lx***** ~]# lsscsi -t [1:0:0:0] cd/dvd ata: /dev/sr0 [2:0:0:0] disk sas:0x5000c295ab45704e /dev/sda [3:0:0:0] disk sas:0x5000c2932dfa693f /dev/sdb [3:0:1:0] disk sas:0x5000c29dcd64314a /dev/sdc As you can see, the uuid string of disk /dev/sda looks somehow familiar to the string that is visible in the VMware API. Only the first hex digit is different (5 vs. 6) and it is only present to the third hyphen. So this looks promising... Alternative idea Select disks by controller. But is it reliable that the ascending SCSI Id also matches the next vSphere virtual disk? What happens if I add another DVD-ROM drive / USB Thumb drive? This will probably introduce new SCSI devices in between. Thats the cause why I think I will discard this idea. Questions Does someone know an easier method to map vSphere disks and Linux devices? Can someone explain the differences in the uuid strings? (I think this has something to do with SAS adressing initiator and target... WWN like...) May I reliably map devices by using those uuid strings? How about SCSI virtual disks? There is no uuid visible then... This task seems to be so obvious. Why doesn't Vmware think about this and simply add a way to query the disk mapping via Vmware Tools?