Search Results

Search found 20796 results on 832 pages for 'active window'.

Page 403/832 | < Previous Page | 399 400 401 402 403 404 405 406 407 408 409 410  | Next Page >

  • how to install expect for windows 64 bit?

    - by Master James
    1.Downloaded Active Tcl from http://www.activestate.com/activetcl/downloads/ 2.Installed @ c:/Tcl/ 3.Go to Bin directory in Command prompt (Start Run commad cd c:\Tcl\bin) 4.To install Expect, executed command teacup install Expect It Appears as : Resolving Expect ... Not found in the archives. While a more fuzzy search disregarding letter case and accepting substrings was done, we are sorry to say that it yielded no possible candidates for installation either. Questions to consider: Have you spelled the name correctly ? Including the proper case of characters ? Note that teacup's 'search' command allows you to locate packages by subject, categories, and the like. Aborting installation, was not able to locate the requested entity. How to install Expect for windows 7, 64 bit ?

    Read the article

  • How to prevent mod_cluster as single point failure?

    - by Hitesh
    In my configuration i used Apche+mod_cluster as a front_end(load balancer) server and two JBOSS AS 7.1.0 as backend server. In my configuration on one system i have install Apache+mod_cluster + JBOSS AS 7.1.0 and on other system JBOSS AS 7.1.0. Both JBOSS AS 7.1.0 are in domain mode means in clustering. My problem is that if Apche+mod_cluster crash than client can not access any JBOSS AS . I want to configure Apache+mod_cluster in Master_Slave format, means if one of Apache+mod_cluter down another Apache+mod_cluster become active and pass client(browser) request to back-end server in normal form without any interruption. Is there any way to make two Apache+mod_cluster to communicate with each other , means to check health status of each other and if any one get down other Apche+mod_cluster will do it's task ......

    Read the article

  • Dell Dimension running Fedora12 does a "Sleeping Beauty" and I am not a "handsome prince"!

    - by Jim Dobbs
    Dell Dimension 2350 with a Pentium IV processor and integrated video and network chips running Fedora12 does a "Sleeping Beauty" and I, apparently, am not am not a "handsome prince"! The system puts video and network to sleep and it will not wakeup. I have heard of this problem on laptops, but this is a tower. Any ideas or help is appreciated. I tried to ping the network card from another system and ping fails. The logs indicate that the system continues to be active. Pressing keyboard short-cut keys makes the disk light blink but neither the video or network card comes alive. Failing all else, are there any Linux commands that I could schedule in cron to pulse video and network adapters hourly that will keep them awake? Or, should I wait on Fedora13? Before this machine, I built a Dimension 2400 with Pentium IV and it had the same problem. Fedora9 on the same hardware is fine.

    Read the article

  • WPF binding problem

    - by xine
    I've got some bindings in UI: <Window x:Class="Tester.MainWindow" xmlns="http://schemas.microsoft.com/winfx/2006/xaml/presentation" xmlns:x="http://schemas.microsoft.com/winfx/2006/xaml" Title="MainWindow" Height="377" Width="562" xmlns:my="clr-namespace:MyApp"> <Grid> <TextBlock Text="{Binding Path=current.Text}" Name="Text1" /> <TextBlock Text="{Binding Path=current.o.Text}" Name="Text2" /> </Grid> </Window> Code: class Coordinator : INotifyPropertyChanged{ List<Myclass1> list; int currId = 0; public Myclass1 current{ return list[currId]; } public int CurrId { get { return currId; } set { currId = value; this.PropertyChanged(this,new PropertyChangedEventArgs("current")); } } class Myclass1{ public string Text{get;} public Myclass2 o{get;} } class Myclass2{ public string Text{get;} } When currId changes Tex1 in UI changes too,but Text2 doesn't. I'm assuming this happens because Text2's source isn't updated. Does anyone know how to fix it?

    Read the article

  • Is it possible to render PDF (fPDF) via a javascript?

    - by J. LaRosee
    So, I'm passing some values via jQuery to the server, which generates PDF garble. It goes something like this: $.post('/admin/printBatch', data, // Some vars and such function(data){ if(data) { var batch = window.open('','Batch Print','width=600,height=600,location=_newtab'); var html = data; // Perhaps some header info here?! batch.document.open(); batch.document.write(html); batch.document.close(); $( this ).dialog( "close" ); // jQuery UI } else { alert("Something went wrong, dawg."); } return false; }); The output file looks roughly like so: $pdf->AddPage(null, null, 'A PDF Page'); //.... $pdf->Output('', 'I'); // 'I' sends the file inline to the browser (http://fpdf.org/en/doc/output.htm) What gets rendered to the browser window: %PDF-1.3 3 0 obj <> endobj 4 0 obj <> stream ... I'm missing something major, I just know it... thoughts? Thanks, guys.

    Read the article

  • How do I stop CRM from asking for admin credentials when printing report

    - by Ac0ua
    Problem: When printing a report in CRM, I am asked by the UAC for admin credentials. There is a long URL: https://(crm_hostname)/reserved.ReportViewerWebcontrol.axd?ReportSession=(ID)ControlID=(ID)Culture=1333&UICulture=1033&ReportStack=1&OpType=PrintCab Info: There are three users that have the issue laied out here. They are not admins of any kind. It looks like it is asking for permission to allow SQL Server Reporting Services 2008 to run. When I put my credentials in, it just brings up the Print dialog box (this is fine, just stop asking for credentials). I know this might sound silly but I downloaded and installed "SQL Server Reporting Services 2008" hopping my credentials would give permission right from the beginning. Giving the users local admin, I was told is not an option. Note: I did post this on community (dot) dynamics (dot) com but, they are not a very active website. Thanks for any help even if it just points me in the right direction!

    Read the article

  • Why does my screen dim on a desktop installation of Windows 7?

    - by Robert Cartaino
    Periodically, while using my Windows 7 Pro desktop installation, the screen suddenly dims. The brightness is about 75% normal (estimate). It's as if I am in a power-saving mode on a laptop running on batteries. But this is a full desktop installation. I know it is not a hardware glitch or monitor adjustment issue because the Windows cursor is still bright white while everything else goes dim. The Control Panel Power Options have not been changed. They are set to "Balanced [active]" and I have tried restoring the default settings. Flipping through the power and display settings, everything looks "normal." There is no screen saver or power-off-after settings apparent. Rebooting the system resets everything to full brightness but I can't find a way to restore it in Windows or to keep it from happening in the first place. Suggestions?

    Read the article

  • What does 'postMessage()' do when called on an object tag?

    - by Stephano
    I was recently searching for a way to call the print function on a PDF I was displaying in adobe air. I solved this problem with a little help from this fellow, and by calling postMessage on my PDF like so: //this is the HTML I use to view my PDF <object id="PDFObj" data="test.pdf" type="application/pdf"/> ... //this actionscript lives in my air app var pdfObj:Object = htmlLoader.window.document.getElementById("PDFObj"); pdfObj.postMessage([message]); I've tried this in JavaScript as well, just to be sure it wasn't adobe sneaking in and helping me out... var obj = document.getElementById("PDFObj"); obj.postMessage([message]); Works well in JavaScript and in ActionScript. I looked up what the MDC had to say about postMessage, but all I found was window.postMessage. Now, the code works like a charm, and postMessage magically sends my message to my PDF's embedded JavaScript. However, I'm still not sure how I'm doing this. Any ideas?

    Read the article

  • Getting base address of a process

    - by yoni0505
    I'm trying to make a program that read the timer value from Minesweeper. (OS is windows 7 64bit) Using cheat engine I found the base address of the variable, but it changes every time I run Minesweeper. What do I need to do to find out the base address automatically? Does it have something to do with the executable base address? Here's my code: #include <windows.h> #include <iostream> using namespace std; int main() { DWORD baseAddress = 0xFF1DAA38;//always changing DWORD offset1 = 0x18; DWORD offset2 = 0x20; DWORD pAddress1; DWORD pAddress2; float value = 0; DWORD pid; HWND hwnd; hwnd = FindWindow(NULL,"Minesweeper"); if(!hwnd)//didn't find the window { cout <<"Window not found!\n"; cin.get(); } else { GetWindowThreadProcessId(hwnd,&pid); HANDLE phandle = OpenProcess(PROCESS_VM_READ,0,pid);//get permission to read if(!phandle)//failed to get permission { cout <<"Could not get handle!\n"; cin.get(); } else { ReadProcessMemory(phandle,(void*)(baseAddress),&pAddress1,sizeof(pAddress1),0); ReadProcessMemory(phandle,(void*)(pAddress1 + offset1),&pAddress2,sizeof(pAddress2),0); while(1) { ReadProcessMemory(phandle,(void*)(pAddress2 + offset2),&value,sizeof(value),0); cout << value << "\n"; Sleep(1000); } } } }

    Read the article

  • Reshape linux md raid5 that is already being reshaped?

    - by smammy
    I just converted my RAID1 array to a RAID5 array and added a third disk to it. I'd like to add a fourth disk without waiting fourteen hours for the first reshape to complete. I just did this: mdadm /dev/md0 --add /dev/sdf1 mdadm --grow /dev/md0 --raid-devices=3 --backup-file=/root/md0_n3.bak The entry in /proc/mdstat looks like this: md0 : active raid5 sdf1[2] sda1[0] sdb1[1] 976759936 blocks super 0.91 level 5, 64k chunk, algorithm 2 [3/3] [UUU] [>....................] reshape = 1.8% (18162944/976759936) finish=834.3min speed=19132K/sec Now I'd like to do this: mdadm /dev/md0 --add /dev/sdd1 mdadm --grow /dev/md0 --raid-devices=4 --backup-file=/root/md8_n4.bak Is this safe, or do I have to wait for the first reshape operation to complete? P.S.: I know I should have added both disks first, and then reshaped from 2 to 4 devices, but it's a little late for that.

    Read the article

  • Trouble with installing VMWare-Player 3

    - by Peachy65
    After downloading the VMware-Player 3 from the VMware-Site I wanted to install it; because I used an older VMware-Player the system wanted this to be deinstalled this version first. After starting the deinstallation I had trouble with my machine - shutdown - now I have no proper deinstallation of the older VMware-Player and everytime, I want to install the 3.0, I get an error-message. Is there any possibility, to clean up the rest of the older installation (3-4 processes are still active or are starting again, when I try to close them and therefore I can't delete different .dll-files by hand)? Thanks for your help!

    Read the article

  • Intercepting hyperlinks in an embedded Word document

    - by Ryan
    Hello, I'm working on an app which uses embedded Word documents. We have a feature which allows them to insert a small clickable image into the doc - when the user clicks on it, we want the app to open another window based on some data specified by the user when the image was added. What the application does now is: When the image is inserted, the app creates a hyperlink for it and the data is used as the link destination The user ctrl+clicks on the image and the Word document the WindowSelectionChange event The app handles the WindowSelectionChange event and goes to open the specified window This approach worked fine with previous versions, when we had the 11.0 / Word 2003 interop dll's. We upgraded to 12.0/Word 2007 for the upcoming release, and in many cases the event is not firing when I click on the image - sometimes it does, sometimes it doesn't, and I'm descending into the cargo-cult world trying to figure out why - sometimes saving and re-opening the document works, sometimes killing the Word process and starting a new one fixes (or breaks) the feature. My guess is there's something going wrong with the WinSelChg event, but I'm not sure what. The usual process we have for applying the event handler is: try //remove the old one if any { ((Document)myAXFramerControl.ActiveDocument).Application.WindowSelectionChange -= new ApplicationEvents4_WindowSelectionChangeEventHandler(WSC_eventhandlerfunction); } catch{} ((Document)myAXFramerControl.ActiveDocument).Application.WindowSelectionChange += new ApplicationEvents4_WindowSelectionChangeEventHandler(WSC_eventhandlerfunction); Sometimes one or both of these will throw exceptions - usually a NullReferenceException when removing the handler. Adding the handler sometimes throws the "com object that has been separated from its underlying rcw cannot be used" exception, which I don't understand at all - my impression was that this only occurs when you, say, store a reference to the Word application or document and try to use it later. As it stands the WSC event handler is frequently never run; while I'm happy to fiddle with the app until it works once I can't really expect the same of the users who have been happily using this feature for a while now. Any ideas?

    Read the article

  • CPU sometimes hangs at 50% maximum on Windows 8

    - by Martin.
    Recently I installed Windows 8 on my HP ProBook 6450b and it appears I've got problems when using more than one program at once. Sometimes, when I run multiple programs at once, CPU hangs at 49% and never goes up. I suspect it has something to do with CPU throttling, because sometimes it just goes over 49%. I've got my notebook connected to charger and my plan is set to "Active cooling". The weird thing is that this happens only occasionally. I found nothing in my BIOS that could change this kind of things.

    Read the article

  • loading google maps drawing manager object

    - by psychok7
    So i am using Google Maps Drawing Manager to draw some polygons and i am saving the lat e long coordinates to my database. Now my question is, after i load that to my array, how can i rebuild the saved polygon back into my map? I can't seem to find a code to understand that. this is what i have now : window.initialize_2 = function () { var mapOptions = { center: new google.maps.LatLng(-34.397, 150.644), zoom: 8, mapTypeId: google.maps.MapTypeId.ROADMAP }; var map = maplimits; var drawingManager = new google.maps.drawing.DrawingManager({ drawingMode: google.maps.drawing.OverlayType.MARKER, drawingControl: true, drawingControlOptions: { position: google.maps.ControlPosition.TOP_CENTER, drawingModes: [ google.maps.drawing.OverlayType.POLYGON] }, markerOptions: { icon: 'images/beachflag.png' }, polygonOptions: { fillColor: '#ffff00', fillOpacity: 10, strokeWeight: 5, clickable: true, editable: true, zIndex: 1 } }); var coord_listener = google.maps.event.addListener(drawingManager, 'polygoncomplete', function (polygon) { var coordinates = (polygon.getPath().getArray()); console.log(coordinates); window.poly = polygon; }); //delete shape google.maps.event.addListener(drawingManager, 'overlaycomplete', function (e) { if (e.type != google.maps.drawing.OverlayType.MARKER) { // Switch back to non-drawing mode after drawing a shape. drawingManager.setDrawingMode(null); // Add an event listener that selects the newly-drawn shape when the user // mouses down on it. var newShape = e.overlay; newShape.type = e.type; google.maps.event.addListener(newShape, 'click', function () { setSelection(newShape); }); setSelection(newShape); } }); // Clear the current selection when the drawing mode is changed, or when the // map is clicked. google.maps.event.addListener(drawingManager, 'drawingmode_changed', clearSelection); google.maps.event.addListener(map, 'click', clearSelection); drawingManager.setMap(map); }

    Read the article

  • OpenGL Tearing Problem

    - by kaykun
    Hi, I'm using win32 and opengl and I have a window set up with the projection at glOrtho of the window's coordinates. I have double buffering enabled, tested it with glGet as well. My program always seems to tear any primitives that I try to draw on it if it's being constantly translated. Here is my OpenGL initialization function: glClearColor(0.0f, 0.0f, 0.0f, 1.0f); glViewport(0, 0, 640, 480); glMatrixMode(GL_PROJECTION); glLoadIdentity(); glOrtho(0, 640, 0, 480, 0, 100); glMatrixMode(GL_MODELVIEW); glLoadIdentity(); glDrawBuffer(GL_BACK); glLoadIdentity(); And this is my rendering function, gMouseX and gMouseY are the coordinates of the mouse: glClear(GL_COLOR_BUFFER_BIT | GL_DEPTH_BUFFER_BIT); glTranslatef(gMouseX, gMouseY, 0.0f); glColor3f(0.5f, 0.5f, 0.5f); glBegin(GL_TRIANGLES); glVertex2f(0.0f, 128.0f); glVertex2f(128.0f, 0.0f); glVertex2f(0.0f, 0.0f); glEnd(); SwapBuffers(hDC); The same tearing problem occurs regardless of how often the rendering function runs. Is there something I'm doing wrong or missing here? Thanks for any help.

    Read the article

  • Upgrading from php 5.3 to php 5.4 with Macport

    - by dr.stonyhills
    PHP5.4 has been available for sometime now and Macport recently caught up with the release of port php54 but the process of upgrading is not as clear as possible. Even worst for those who are new to maintaining multiple versions of PHP on the same machine. I am keen on trying out some of the new features in PHP5.4 like traits, new array form etc but falling back on to php5.3 for other compatibility stuff. So i sudo port install php5+ (all the variants, apache2 etc) Then i tell it what PHP port to use as default sudo port select --set php php54 Check what version of PHP is active in the terminal using php -v outputs php 5.4.3. But i seem to be having issues with choosing the right non cli version as in the version of the module run by apache etc is still php5.3.12. Do i have to change the reference to the libphp5 in apache httpd.conf? Any advice on the right workflow for switching between php version on macport greatly appreciated!

    Read the article

  • CentOS Vs Windows Server 2008

    - by Steve
    Hi, Apologies if the question appears ambiguous, I have little experience in this area and was after some informed opinions. I am deploying a test scenario of a server/client network and need to make some choices for Server. The client will be a Windows system as it meets the requirements for the client, the server choice has more room for selection. From my experience with Linux in general and the appealing nature of open source for low cost, security etc and the availability and performance of database and web server programs I have been considering CentOS as a server choice. I have the ability to make most of the choices of what software / server packages I wish to install. This includes Active Directory (something I have no experience with). How well does this operate with Windows clients? Am I being too selective and creating unnecessary complication by setting out not to use a Windows Server OS?

    Read the article

  • Public IP shows strange characters and Facebook registers logged-in session to a different location

    - by Stuart Kershaw
    I'm encountering some IP strangeness today and hoping to find an explanation. In short, I'm based in Seattle, WA with my ISP being Comcast. While browsing Facebook's account settings, I noticed that my active session was located to Mount Laurel, NJ. At that point I ran a search in Google for 'my public IP', which returned an interesting result: a string of characters in the following format: 2601:8:b000:xxx:xxxx:xxxx:xxxx:xxxx Normally, a search for my IP returns something like: 67.xxx.xx.xxx A phone call to Comcast got me nowhere, but using Comcast's phone-menu debugging tools, I was able to send a 'refresh signal' to my modem. After that, the search for 'my public IP' yielded the expected result... for about 5 minutes, and then it returned to the new string of characters. Does anyone know of an explanation for this?

    Read the article

  • In CSS, how to not float a 300px wide Div to the next line?

    - by Jian Lin
    Say, there is a bar that is styled at the bottom of the viewport, using position: fixed; bottom: 0; left: 0; width: 100%; height 50px; overflow: hidden and then there are 4 Divs inside it, each one floated to the left. Each Div is about 300px wide or can be more (depending on the content) Now, when the window is 1200 pixel wide, and we see all 4 Divs, but when the window is resize to be 1180 pixel wide (just 20 pixels less), then the whole 300px wide Div will disappear, because it is "floated" to the next line. So how can this be made so that, the Div will stay there and showing 280px of itself, rather than totally disappear? By the way, white-space: nowrap won't work as that probably has to do with not wrapping inline content. I was thinking of putting another Div inside this Div, having a fixed width of 1200px or 2000px, so that all Divs will float on the same level in this inner Div, and the outer Div will cut it off with the overflow: hidden. But this seems more like a hack... since the wide of all those Divs can be dynamic, and setting a fixed width of 1200px or 2000px seems like too much of a hack.

    Read the article

  • VPN trace route

    - by Jake
    I am inside an Active Directory (AD) domain and trying to trace route to another AD domain at a remote site, but supposedly connected by VPN in between. the local domain can be accessed at 192.168.3.x and the remote location 192.168.2.x. When I do a tracert, I am suprised to see that the results did not show the intermediate ISP nodes. If I used the public IP of the remote location, then a normal tracert going through every intermediate node would show. 1 <1 ms <1 ms <1 ms 192.168.3.1 2 1 ms <1 ms <1 ms 192.168.3.254 3 7 ms 7 ms 7 ms 212.31.2xx.xx 4 197 ms 201 ms 196 ms 62.6.1.2xx 5 201 ms 201 ms 210 ms vacc27.norwich.vpn-acc.bt.net [62.6.192.87] 6 209 ms 209 ms 209 ms 81.146.xxx.xx 7 209 ms 209 ms 209 ms COMPANYDOMAIN [192.168.2.6] Can someone explain how does this VPN tunnelling works? Does this mean VPN is technically faster than without?

    Read the article

  • Dell Dimension 2350 with a Pentium IV processor and integrated video and network chips running Fedor

    - by Jim Dobbs
    Dell Dimension 2350 with a Pentium IV processor and integrated video and network chips running Fedora12 does a "Sleeping Beauty" and I, apparently, am not am not a "handsome prince"! The system puts video and network to sleep and it will not wakeup. I have heard of this problem on laptops, but this is a tower. Any ideas or help is appreciated. I tried to ping the network card from another system and ping fails. The logs indicate that the system continues to be active. Pressing keyboard short-cut keys makes the disk light blink but neither the video or network card comes alive. Failing all else, are there any Linux commands that I could schedule in cron to pulse video and network adapters hourly that will keep them awake? Or, should I wait on Fedora13? Before this machine, I built a Dimension 2400 with Pentium IV and it had the same problem. Fedora9 on the same hardware is fine.

    Read the article

  • Can't select hard disk off Windows 7 system image creator

    - by David
    When I try to create a system image in Windows 7 from the Control Panel (Control Panel\All Control Panel Items\Backup and Restore) I get the option to select a hard disk or a removeable disk to select, I have 2 disks and wanted to create the image on my spare one. However when I click refresh it doesn't show either of my disks but shows my CDROM under the removable disks area, anyone have this problem? Also, when I select a USB disk instead, it tries to iamge both my disks! I can't select my active Windows 7 installed disk! How pointless!

    Read the article

  • Storage product testing

    - by wildchild
    hello, I know this is out of place (being an active member here i am coming for the help from seniors) ,but i need some information regarding storage testing ,testing of Raid arrays, SCSI, SAS ,SATA and also test carried out on fabric manager(Cisco MDS series switches). I am aware that this is an administrative forum and i would really appreciate if you could direct me to the correct forum ar links where i can learn things . @ moderators-Sorry for posting at the wrong place,i would be deleting this as soon as i get the help. Thanks !

    Read the article

  • Looking for a router-like web interface for my Debian gateway.

    - by marcusw
    Hey, I need a web interface program for my debian gateway which has the features of a router's one. Specifically, I must be able to easily Forward ports to various clients on the LAN or the router itself (it's also a server) Manage a DHCP server preferably including DHCP reservation for certain MACs Give me a list of the connected DHCP clients (optionally) Show which clients are the most active as far as bandwidth (something like iftop) Alternatively, it could be a graphical app which I could tunnel over ssh. No command line programs please...I'm used to doing this stuff with a point-and-click interface. Not adverse to command-line setup; just need to be able to reconfigure things graphically. Have a working LAMP setup. I've tried webmin, but it didn't satisfy the "easy" part...too many clicks and too many meny options.

    Read the article

  • Performance improvements of VBulletin by integrating the plugins

    - by reggie
    I have amassed quite a lot of plugins and code that is being hooked into VBulletin's plugin system. There are good uses for this system. But since I am now locked in with the VB 3 branch and it is no longer updated, I wonder what kind of performance improvements I would see if I integrated all the plugins into the vbulletin files and turned the plugin system completely off. My site has about 1.5 mio posts, about 100,000 threads, 100,000 members (of which 10,000 are "active"). I estimate I have about 200 plugins from different products in the plugin manager. Has anybody ever tried this move and could share the experiences?

    Read the article

< Previous Page | 399 400 401 402 403 404 405 406 407 408 409 410  | Next Page >