Search Results

Search found 18011 results on 721 pages for 'split window'.

Page 444/721 | < Previous Page | 440 441 442 443 444 445 446 447 448 449 450 451  | Next Page >

  • White Screen, No Errors.

    - by GruffTech
    So.. Interesting problem for you guys, As I'm completely lost as to what to do, or where to take the next step. Server & Application Environment. CentOS release 5.3 (Final) Apache 2.2.3-22 EnableSendfile off EnableMMAP off ErrorLog logs/error_log LogLevel debug PHP-5.2.6-2 error_reporting = E_ALL display_errors = on log_errors = on max_execution_time=300 max_input_time=60 memory_limit=512mb Kohana 2.3 PHP Environment. HAProxy 1.3.15.6-2 MemCacheD 1.2.6-1 Our application is split between 3 web servers, mounting a NFS Storage server, and sticky load balancing between the 3 web servers. The application seemingly runs great, but every so often, instead of loading, the application just shows a pure white page. Not a 404 Error, or a 500 Server Error, a clean white page. And it returns instantly, so its not a execution time error. Nothing in the Error log, or Server-Error Log, Proxy log shows standard proxied connection, Just the standard 200-Status in Access log, with 256 bytes transferred. To me, this leads to tell me that the application itself is having a problem. A rare, unexplainable, seemingly random, problem that causes what we've now called the "White Screen of Death." Our developers all say that since there is nothing going to our error logs, that it must be a server problem. But I say the same thing, There's nothing going to ANY of our logs (relevent to this anyway), and we're not having httpd children crash from what i can tell. Any ideas on how i can increase my logs, or somehow prove that its not a bug in PHP, Apache, CentOS, ect? Or if it is somehow a bug, identify it?

    Read the article

  • SBD killing both cluster nodes when there are even small SAN network problems

    - by Wieslaw Herr
    I am having problems with stonith SBD in a openais-based cluster. Some background: The active/passive cluster has two nodes, node1 and node2. They are configured to provide an NFS service to users. To avoid problems with split-brain, they are both configured to use SBD. SBD is using two 1MB disks available to the hosts via an multipath fibre-channel network. The problems start if something happens with the SAN network. For example, today one of the brocade switches got rebooted and both nodes lost 2 out of 4 paths to each disks, which resulted in both nodes committing suicide and rebooting. This, of course, was highly undesirable because a) there were paths left b) even if the switch would be out for 10-20 seconds a reboot cycle of both nodes would take 5-10 minutes and all NFS-locks would be lost. I tried increasing the SBD timeout values (to 10sec+ values, dump attached at the end), however a "WARN: Latency: No liveness for 4 s exceeds threshold of 3 s" hints that something isn't working as I would it expect to. Here is what I would like to know: a) Is SBD working as it should killing nodes when 2 paths are available? b) If not, is the multipath.conf file attached correct? The storage controller we use is an IBM SVC (IBM 2145), should there be any specific configuration for it? (as in multipath.conf.defaults) c) How should I go about increasing the timeouts in SBD attachements: Multipath.conf and sbd dump (http://hpaste.org/69537)

    Read the article

  • Getting Dell E6320 with I7 to work with 3 monitors at 1920x1080p x 3

    - by MadBoy
    I want to buy Dell E6320 which comes with Intel Core I7-2620M (2.70GHz, 4MB cache, Dual Core) with Intel HD Graphics 3000. Laptop will come with docking station. I want to connect 3 monitors to that docking station so that working at home would give me some additional boost. Docking station will allow me to connect only 2 monitors so I'm looking at following other options: Matrox TRIPLEHEAD2GO DIGITAL Edition or TRIPLEHEAD2GO DP Edition. But reading Matrox Support Page intel GPU can't run the highest resolution with 3 monitors connected, it even gets worse since it seems monitors would have to be able to work at 50hz. Also I'm not sure but it seems that Matrox doesn't split the monitors as 3 separate monitors but simply as one big space (which is a bit opposite to what I need) Buy 2 or maybe just 1 USB based monitor but it would also mean having 1 or 2 different monitors then the main one, unless I buy 3 USB based monitors which would mean more money to spend. Also I found only couple of models and most of them require USB 3.0 and no other cables to plug in (nice but costly - couldn't find decent monitor with only USB for sending signal and having power connected normally) . But docking station has only one USB 3.0 port. Can I use hub and still get it to work? Find some converters from Digital to USB (I think DisplayLink does some?) Buy different laptop but what kind? I need it to be I7, small (13"), fast and lightweight. At same time it requires docking station that I can use at home to connect 3 external monitors. Some other suggested solution... Edit: I need 3 monitors for work in terms of coding in Visual Studio or having word/excel/outlook open. Nothing fancy. Maybe some movie once in a while.

    Read the article

  • Upstart multiple instances of service not working

    - by Dax
    I started playing with MongoDB on Lucid. Now I would like to run a DB and Config server on the same box. They both use the same binary to launch, but with different config files and running on different ports. All directories for log and lib is split so one goes to mongodb and the other to mongoconf. Each process can be started without any problems on their own. start mongodb stop mongodb start mongoconf stop mongoconf But if I try to start both, the second one would just start and exit. Using 'initctl log-priority debug' I got the following in the logs. Jan 6 12:44:12 mongo4 init: event_finished: Finished started event Jan 6 12:44:12 mongo4 init: job_process_handler: Ignored event 1 (1) for process 5690 Jan 6 12:44:12 mongo4 init: mongoconf (mongoconf) main process (5690) terminated with status 1 Jan 6 12:44:12 mongo4 init: mongoconf (mongoconf) goal changed from start to stop Jan 6 12:44:12 mongo4 init: mongoconf (mongoconf) state changed from running to stopping man 5 init shows that you can use instance names to differentiate the two. I tried using 'instance mongoconf' in the on upstart script and 'instance mongodb' in the other one, and it still fails. I can manually start the other process, so there is definitely no conflicts on port numbers or directories. Any ideas on what to try or how to get output on why it is 'terminated with status 1'? Thanx

    Read the article

  • Which upgrade path for disk IO bound postgres server?

    - by user41679
    Hi all, We currently have a Sun x4270 with 2xquad core Xeon Nehalmen 2.93ghz cores (16 threads), 72 gig of ram and 16 x 10k SAS disks split between the os raid 1, a partition for the Write Ahead Logs which is raid 10 and a partition for the database tables and indexes which is also raid 10, all xfs. I'm currently evaluating which path to go down in terms of upgrades. We'll be sharding the DB at some point soon, but for now I need to focus on hardware upgrades specifically. The machine is not CPU or memory bound at all at the moment, just IOWait is become an issue. The machine is mostly write access as we have a heavy caching layer. We're seeing about 300 write IOPS average on both the database partitions. We don't have any additional storage infrastructure like a Fiber Channel or ISCSI network. Budget isn't too much of a concern, something inline with the size of this server (i.e no $1m IBM machines) Space is ok on the DB side of things, we're running out obviously but there's also some reduction we can do. Additional space would be good though. My current thoughts are either: * ISCSI SAN, possible with 10Gbit network that has solid state acceleration. * FusionIO card / Sun F20 card (will the FusionIO card work in the Sun box? * DAS shelf (something like this http://www.broadberry.co.uk/das-direct-attached-storage-servers/cyberstore-224s-das) which a combination of 15k sas disks and some Intel X25-E drives for DB indexes etc) what would I need to put in the x4270 to add a DAS shelf? I think it's a SAS HBA card, do I have to use Sun's own card or will any PCI Express card work? Anything else??? what would you guys do from your experience? I appreciate it's a lot of questions, but I haven't expanded a DB machine for a number of years and the landscape has changed dramatically since then! Any advice or feedback would be very much appreciated. Let me know if there's anything else I can clarify. Thanks in advance!

    Read the article

  • Where to download replacement "Explorerframe.DLL" Files for x64 Windows 7 Pro?

    - by Ben Franchuk
    After posting this question, I did some research to reveal what the problem likely was, and found what I need to fix. Following this is the original post, then my updated question. A few months ago I ended up requiring to change my computer's SID to fix a problem it had been having- Instead of fixing the problem, though, it screwed up my at-the-time current install of windows, to the point of me needing to do a fresh install. As I am in possession of an OEM copy of Windows 7 Pro 64 Bit, I successfully reinstalled over the dead copy with that (all the files that were on the computer previous to this windows install were put in a Windows.old folder). Everything installed and worked absolutely fine, except for one thing. The problem I am experiencing is that, in some Windows Explorer windows, the explorer pane doesn't show. Instead, it simply shows a white area where the pane would show. This makes some software not usable, I recently realized; Software such as Cubase, which use just the explorer pane to select file save locations, cannot save at all as the pane itself is... not operational. Below is a screenshot of this problem as it occurs in cubase; ...and again as it shows in UTorrent in the save location selector window. The highlighted area is where the sidebar would NORMALLY be. Pardon my scribbling over some of the things in the window- I would personally rather the internet did not get a glimpse of my files. I have yet to find a common reason why the pane works in some applications when they pull explorer, and others not. I have yet to see it go away, and the software affected by it has been affected since I reinstalled my copy of windows. Initially, I was able to live with it as I can type out save locations in the file name bar to navigate, but with software like Cubase, I do not have this option. Reinstalling windows again is NOT an option. Here's the updated question. After posting this question originally, I did some research on the problem in question, and it turns out that this is extremely easily fixable via replacing the file "ExplorerFrame.DLL" which is located in the System32 and SystemWOW64 Folders, in the windows folder, on the C:\ drive. As I quite frequently customize my computer, this is a normal thing for me to do and I know exactly how to safely and properly replace this file. The only problem is that I cannot for the life of me find a download of this file that actually works with my computer. I tried a couple from some different sites but they all caused explorer to not restart (I was given an error when starting the application from Task Manager) and was forced to revert to the broken .DLL files. Since there are 2 separate "ExplorerFrame.DLL" files; one for 64 bit and the other for 32 bit, I am assuming that I will need to download 2 separate versions to replace the corrupted ones. Where can I acquire these files? I am currently running Windows 7 Professional x64 Bit.

    Read the article

  • What's wrong with this vcl config for varnish-cache as load balancer?

    - by dabito
    I have the current configurations active on my default.vcl varnish file on the machine that balances the load for other two machines (the other two machines also have varnish active). My intention is to have this server do only the load balancing and the other machines do the processing and also their own caching. My problem is that even with the config testing (not even a stress test or anything, just a few requests a minute) I get the guru meditation error and have to restart varnish. This is the default.vcl for the load balancing server: backend vader { .host = "app1.server.com"; .probe = { .url = "/"; .interval = 10s; .timeout = 4s; .window = 5; .threshold = 3; } } backend malgus { .host = "app2.server.com"; .probe = { .url = "/"; .interval = 10s; .timeout = 4s; .window = 5; .threshold = 3; } } director dooku round-robin { { .backend = vader; } { .backend = malgus; } } sub vcl_recv { if (req.http.host ~ "^balancer.server.com$") { set req.backend = dooku; } } Am I doing something wrong or missing something? EDIT: This is varnishlog's output: 0 CLI - Rd ping 0 CLI - Wr 200 19 PONG 1345839995 1.0 0 CLI - Rd ping 0 CLI - Wr 200 19 PONG 1345839998 1.0 0 CLI - Rd ping 0 CLI - Wr 200 19 PONG 1345840001 1.0 0 Backend_health - malgus Still sick 4--X--- 0 3 5 0.000000 3.846876 0 Backend_health - vader Still sick 4--X--- 0 3 5 0.000000 3.839194 0 CLI - Rd ping 0 CLI - Wr 200 19 PONG 1345840004 1.0 14 SessionOpen c 10.150.7.151 38272 :80 14 ReqStart c 10.150.7.151 38272 458200540 14 RxRequest c GET 14 RxURL c / 14 RxProtocol c HTTP/1.1 14 RxHeader c Host: dooku-dev.excelsior.com 14 RxHeader c Connection: keep-alive 14 RxHeader c User-Agent: Mozilla/5.0 (X11; Linux x86_64) AppleWebKit/536.11 (KHTML, like Gecko) Chrome/20.0.1132.47 Safari/536.11 14 RxHeader c Accept: text/html,application/xhtml+xml,application/xml;q=0.9,*/*;q=0.8 14 RxHeader c Accept-Encoding: gzip,deflate,sdch 14 RxHeader c Accept-Language: en-US,en;q=0.8,es-419;q=0.6,es;q=0.4 14 RxHeader c Accept-Charset: ISO-8859-1,utf-8;q=0.7,*;q=0.3 14 RxHeader c Cookie: SESSa87d6c6da0c61037a9169122dc5e4a19=HR_0Srhgc-uDArT3aJFzOBy31FtzneTXg38byr1eGMU; __atuvc=4%7C33 14 VCL_call c recv pass 14 VCL_call c hash 14 Hash c / 14 Hash c dooku-dev.excelsior.com 14 VCL_return c hash 14 VCL_call c pass pass 14 FetchError c no backend connection 14 VCL_call c error deliver 14 VCL_call c deliver deliver 14 TxProtocol c HTTP/1.1 14 TxStatus c 503 14 TxResponse c Service Unavailable 14 TxHeader c Server: Varnish 14 TxHeader c Content-Type: text/html; charset=utf-8 14 TxHeader c Retry-After: 5 14 TxHeader c Content-Length: 418 14 TxHeader c Accept-Ranges: bytes 14 TxHeader c Date: Fri, 24 Aug 2012 20:26:44 GMT 14 TxHeader c X-Varnish: 458200540 14 TxHeader c Age: 0 14 TxHeader c Via: 1.1 varnish 14 TxHeader c Connection: close 14 Length c 418 14 ReqEnd c 458200540 1345840004.916415691 1345840004.965190172 0.020933390 0.048741817 0.000032663 14 SessionClose c error 14 StatSess c 10.150.7.151 38272 0 1 1 0 1 0 256 418 14 SessionOpen c 10.150.7.151 38273 :80 14 ReqStart c 10.150.7.151 38273 458200541 14 RxRequest c GET 14 RxURL c /favicon.ico 14 RxProtocol c HTTP/1.1 14 RxHeader c Host: dooku-dev.excelsior.com 14 RxHeader c Connection: keep-alive 14 RxHeader c Accept: */* 14 RxHeader c User-Agent: Mozilla/5.0 (X11; Linux x86_64) AppleWebKit/536.11 (KHTML, like Gecko) Chrome/20.0.1132.47 Safari/536.11 14 RxHeader c Accept-Encoding: gzip,deflate,sdch 14 RxHeader c Accept-Language: en-US,en;q=0.8,es-419;q=0.6,es;q=0.4 14 RxHeader c Accept-Charset: ISO-8859-1,utf-8;q=0.7,*;q=0.3 14 RxHeader c Cookie: SESSa87d6c6da0c61037a9169122dc5e4a19=HR_0Srhgc-uDArT3aJFzOBy31FtzneTXg38byr1eGMU; __atuvc=4%7C33 14 VCL_call c recv pass 14 VCL_call c hash 14 Hash c /favicon.ico 14 Hash c dooku-dev.excelsior.com 14 VCL_return c hash 14 VCL_call c pass pass 14 FetchError c no backend connection 14 VCL_call c error deliver 14 VCL_call c deliver deliver 14 TxProtocol c HTTP/1.1 14 TxStatus c 503 14 TxResponse c Service Unavailable 14 TxHeader c Server: Varnish 14 TxHeader c Content-Type: text/html; charset=utf-8 14 TxHeader c Retry-After: 5 14 TxHeader c Content-Length: 418 14 TxHeader c Accept-Ranges: bytes 14 TxHeader c Date: Fri, 24 Aug 2012 20:26:45 GMT 14 TxHeader c X-Varnish: 458200541 14 TxHeader c Age: 0 14 TxHeader c Via: 1.1 varnish 14 TxHeader c Connection: close 14 Length c 418 14 ReqEnd c 458200541 1345840005.226389885 1345840005.226457834 0.000026941 0.000043154 0.000024796 14 SessionClose c error 14 StatSess c 10.150.7.151 38273 0 1 1 0 1 0 256 418

    Read the article

  • Keyboard doesn't function after Fedora 17 update

    - by mickburkejnr
    I updated my Fedora 16 installation to Fedora 17 on Saturday, and the update worked without reporting any errors. I carried on working on the machine in question and then switched the computer off. Last night I went back on the computer, I switched it on and got to the log in screen. At this point I tried to type in my password but the keyboard wouldn't work. I unplugged it (it's a PS/2 keyboard) and plugged it back in. The lights flashed for a split second but the keyboard still wouldn't work. I then plugged the keybaord in to a USB to PS/2 adapter, and the keyboard still wouldn't work. I restarted the computer and tried to access the BIOS and I was able to do so. So the keyboard doesn't seem to be faulty, it just doesn't work when Fedora boots in to the GUI interface. I did try to boot in to the "recovery mode" of Fedora, and the keyboard works here with no problem. As I still have access to Fedora via a terminal interface, is there anything I can do to fix the keyboard problem via the terminal without having to reinstall Fedora?

    Read the article

  • Strange battery behavior on laptop

    - by EpsilonVector
    My laptop is behaving rather strangely lately, and I was hoping to get some idea as to what may be causing such symptoms. The problem: When charging, very minute or so it loses connectivity with the AC adapter for a split second, and regains it back immediately. When this happens the little light that indicates the computer is plugged in does flicker off and back on, but I checked the adapter by replacing the battery on my laptop, and this indeed solves the problem, so it is probably the battery which is at fault, not the adapter (I also tried to move the adapter's wire around just to make sure it had nothing to do with torn wires). I suppose that the obvious solution is to get a new battery, but as far as battery defects go- this is a rather strange one; it loses connection with the adapter, but still powers the computer, and changing the power setting to a balanced plan (was maximum performance) seem to have solved the problem too. Is there a chance this is not simply the battery, but some kind of other electronic defect? And if not, what can cause it to behave so strangely? PS I tried to recalibrate it- didn't help.

    Read the article

  • Varnish with multiple sites/boxes

    - by jerhinesmith
    Is it possible for Varnish to redirect traffic to different IPs based on the url? For example, is the following setup feasible (and if so, what would the VCL look like): *.example.com points to Varnish IP address When a request is made to foo.example.com, varnish checks the cache and sends the request to Server1's IP address on a cache miss. When a request is made to bar.example.com, varnish checks the cache and sends the request to Server2's IP address on a cache miss. foo and bar are (for the most part) completely unrelated sites. They use the engine, but have different content and their own distinct database. Since there previously was no penalty for doing so (other than cost) we split them up into two separate boxes so that a ton of traffic to foo won't have a negative impact on visitors browsing around bar. I could set up two instances of varnish and have one serve up foo's static content and the other serve up bar's, but as there doesn't seem to be much overhead to running Varnish, I think (perhaps mistakenly) that it would make more sense to go with one Varnish server that redirects the traffic to the appropriate box on a cache miss.

    Read the article

  • What USB key would you recommend using for running a Windows 7 VM off of?

    - by Darryl Hein
    Because I can't find a good PHP editor for OSX, I develop in Windows with PhpEd. At the moment, my development time is split between a desktop and a laptop. To partially solve the problem of having 2 different environments, I have installed a virtual machine (through Virtual Box) and put the hard drive file on an external hard drive. At the moment, I've been connecting it through Firewire 800. I have 2 problems with this setup: (1) The hard drive is fairly large so to carry the laptop and hard drive I pretty much require a backpack. (2) The hard drive requires quite a bit of power and therefore reduces the battery life (by about 40%). My thought is to move the VM hard drive onto a USB key. I realize it will be slower, but as I'm just using it for PHP development, there isn't a lot of disk activity in the VM. The only really intense time is boot up, otherwise, it just about sits idle. Do anyone have any suggestions on a USB key to use for the VM? It would need to a minimum of 32GB.

    Read the article

  • How to prevent asymmetric routing with multiple eBGP routers?

    - by Andy Shinn
    I have 2 routers announcing a /22 subnet to different providers (one providers connects to each of the 2 routers). I have split the /22 in two /23 to announce one /23 on each of the routers plus the /22 (the providers will take the more specific route). This allows me to fail over and keep traffic inside the /23 in and out the same provider. What are other ways in which I could announce just the /22 with both routers and have packets from servers on the network behind the routers go back out the same router in which they came in from? EDIT: The main problem I come across, which end users and clients complain about the most, is that the least hop route is sometimes not the "optimal" route. In my case, I know that Provider B may have better latency to X nation. But when packets come in from provider B, they may go out Provider A or provider B. The reverse is also true. If I send a packet to X nation out provider A, even though it may have more hops back, the packet will likely come in from Provider B (which may have higher latency, packet loss, etc. to this nation)

    Read the article

  • SQuirreL Client: Opening up a table in a separate tab

    - by Dalin Seivewright
    I've switched to SQuirrel Client to view an Oracle database with a variety of tables. At any given time, I need to look at the contents of several related tables at the same time. The problem is that, at least by default, SQuirrel Client does not open up multiple tables at a time. When you click on a different Table object, the main view is refreshed with newly selected table data. Oracle's SQLDeveloper (which I am trying to move away from) did this by default if I recall, but there was an option to "freeze" panes. Does a similar option exist in SQuirrel Client? I do not require the ability to view the contents of two different tables on the same screen (i.e. a split view) but I would like the ability to have tabs for each table so I can quickly switch between each table view rather then having to find the table in the table list over and over again. Note: I am using this in a professional capacity but if it does not "belong" here then I suppose it could be moved to superuser.

    Read the article

  • What is the max supported number of SATA devices (using cable adapters) on a Dell SAS 6/iR adapter?

    - by Zac B
    I've got a Dell SAS 6/iR PCI-E adapter. I don't have a multiplier backplane. I'm planning on connecting SATA (non SAS) drives. If I buy cable adapters only (ones that split a SAS connector on the card to a certain number of SATA cables), how many drives can I connect to this card? The way I see it, there are two limitations: a limitation imposed by the theoretical max number of devices supported on the card (which I've dug through the specs to find, but haven't seen yet), and a limitation imposed by the number of SAS plugs on the card multiplied by the number of SATA cables that come out of the highest-multiplying splitter I can buy. The answer to my question would be the minimum of those two limitations. I've seen 4x SATA coming out of some splitters; are there any that have more? Alternatively, if this is an RTFM question, does anyone have a good link to a "this is how SAS works, this is how you figure out the max number of devices, and this is how the concepts of 'ports', 'lanes', 'endpoint devices', and 'connectors' all relate in SAS-land" document? I've looked around on the Dell docs, but haven't found anything that explains this to someone at my level of understanding of SAN/enterprise storage technologies. Cheers!

    Read the article

  • Most cost efficient way to backup Subversion data to S3?

    - by sludge
    I'm looking at using S3 as an offsite backup repo for my Subversion database. When I dump my SVN database, it's about 10 gigabytes. I would like to avoid the charge of uploading that data repeatedly. The anatomy of this large file such that new changes to Subversion modify the tail of the file, with everything else staying the same. Because Amazon S3 does not allow you to "patch" files with changes, I will have to upload ten gigs every time I instantiate a backup after doing a simple submit to Subversion. Here are the options as I see them: Option 1 I am looking at duplicity which has --volsize which splits data over an amount of megs. Is it possible to split the Subversion dumps using this so further incremental backups are measured in megabytes? Option 2 Can I just backup the hot subversion repository? This seems like a bad idea if it is in the middle of writing a submit. However, I have the option of taking the repo offline between the hours of midnight and 4am. Each revision in my Berkeley DB uses a file as its record.

    Read the article

  • Multiple servers vs 1 big server performace

    - by pistacchio
    Hi to all! My team of developers has suggested a server structure for an upcoming project we are developing. Our structure is "logical", meaning that the various logical components of the application (it is a distributed one) relies on different servers. Some components are more critical than others and will be subjected to more load. Our proposal was to have 1 server per component but the hardware guys suggested to replace the various machines with a single, bigger one with virtual servers. They're gonna use Blade Servers. Now, I'm not an expert at all, but my question to the guys was: so if we need, for example, 3 2GHz CPU / 2GB RAM machines and you give me 1 machine with 3 2GHz CPUs and 6 GB of RAM it is the same? They told me it is. Is this accurate? What are the advantages or disadvantages of both the solutions? What are the generally accepted best practices? Could you point out some URL reference dealing with the problem? Thank you in advance! EDIT: Some more info. The (internet / intranet) application is already layered. We have some servers on the DMZ that will expose pages to the internet and the databases are on their own machines. What we want to split (and they want to join) are some webservers that mainly expose webservices. One is a DAL that communicates with the database layer, one is our Single Sign On / User Profile application that gets called once per page and one is a clone of what seen on the Internet to be used on our lan.

    Read the article

  • How do I count the times each number appears in columns of numbers?

    - by Andy C.
    I am sure this must be easy, but I am inexperienced. About the best way to think of my problem is to think of it as trying to sort and then count lottery numbers. To stay simple, let's do a Pick 3 game. Let's look at 10 drawings. I would split each drawn number into a separate column: DATE BALL#1 BALL#2 BALL#3 3/1 1 3 5 3/2 3 7 8 3/3 2 2 1 3/4 5 7 6 3/5 2 3 1 3/6 0 5 9 3/7 3 7 0 3/8 6 8 4 3/9 2 4 3 3/10 7 1 2 I would like to be able to build formulas into cells that would tell me how many times each number appeared overall, and how many times each number appeared in the position it occurred. Like this (using the above example): Number Overall Count Ball#1 Count Ball#2 Count Ball#3 Count 0 2 1 0 1 1 4 1 1 2 (That is, The number zero appears twice overall, and came up once as the first number drawn; zero times as the middle ball; and once as the third ball. Likewise, the number 1 was drawn four times in our 10-day period. It was the first ball once, the second ball once and the third ball twice.) And so on. All help appreciated. I have access to Excel and Microsoft Works, or of course if there is a Google Docs way to handle this All thanks for any help.

    Read the article

  • Exchange 2010 certificate errors

    - by Frederik Nielsen
    I have a problem with my newly setup Exchange environment for our hosted customers. First off, when configuring the outlook client, it gives a certificate warning although the certificate has been bought and setup. I am using a setup like this: autodiscover.CUSTOMERDOMAIN.TLD CNAME autodiscover.exchange.COMPANYDOMAIN.TLD (Companydomain is our company that hosts the exchange servers, customerdomain being the customers domain) Shouldn't that work? I know that Microsoft does something like that for Office365, but I really don't think they buy a certificate for every customer.. So I guess some redirection should be setup somehow - any guidance? Next thing: When we accept that error, and move on to actually starting Outlook, it states that the certificate is not valid for the RPC proxy server exchange.COMPANYDOMAIN.TLD - this domain is not right, as that domain is not included in the certificate. I would instead like this domain to be mail.exchange.COMPANYDOMAIN.TLD I tried to run this script setting both internal and external URL's to be the same, with no luck. Any guidance on this one? I am running Exchange 2010 SP2, with CAS, HT and MBX split up on 3 different servers.

    Read the article

  • Router vs switch in a LAN [closed]

    - by servernewbie
    If I have a LAN and and connect it with a switch, I understand it uses a CAM table to route packets in layer 2 (by saving mac to port relations). So far all good. However, when using a router for a LAN (ONLY for a LAN, not to connect it to "the outside" WAN/internet/etc) I get a bit confused as to how it internally processes packets. I would first split this into two router scenarios: Router with buit-in switch In this scenario, I would expect that it will act exactly as a switch with a CAM table internally. This would probably benefit a bit in speed (guessing here?) compared to the next option. Router without built-in switch Here is where I get confused. If hostA wants to send a packet to hostB, it will ARP to find hostB's MAC address and send it there. Now, if we had a switch (above scenario) this would be easy. But how does it work now in a router WITHOUT a switch? If I would guess, hostA would send an Ethernet frame with hostB's MAC address to the line. The router would fetch the packet (even though the router has another MAC address, it would still fetch this packet even if it only contains hostB's MAC address). It would strip the Ethernet frame header and check the IP, and then check its own internal ARP table again for the MAC address. Now, this would seem like a waste of resources compared to a router with a built-in switch. But maybe it does not work like that at all. Does it also contain a CAM table? If that would be true, what would then the difference between these two routers really be?

    Read the article

  • Puzzling TCP performance over 3G / UMTS

    - by lemonsqueeze
    I'm using 3G as my primary internet connection, and TCP over this thing is getting more puzzling every day. For example: Downloading from kernel.org is crazy fast: $wget http://www.kernel.org/pub/linux/kernel/v3.0/linux-3.6.8.tar.bz2 increases to ~500kB/s after a few secs ! Some servers are incredibly slow, for instance www.graphic-pc.com:Same thing, downloading a big file with wget it starts at ~30kB/s for a split second, then collapses to 5-10k or even worse. Web browsing is decent but somewhat unreliable. Randomly, a page will take really long to load or even fail to load, but a reload can succeed almost immediately. Now, by chance i started playing with OpenVPN over UDP on top of the 3G connection, and OMG suddenly everything's extremely fast !Same www.graphic-pc.com now shoots at 100-200kB/s ! What's going on here ??? How come it is so much better with the VPN than without ?? And why does graphic-pc.com crawl when kernel.org flies ?Something to do with my tcp stack (or the server), or some buggy router in between ?? Notes: Setup is laptop running Ubuntu Lucid and a Huawei 3G dongle (So direct pppd connection). I can reproduce this pretty much any time during the day and I'm not moving, so it's clearly not cell environment or internet congestion. (although kernel.org without VPN sometimes does worse in the evening, 60kB or so - but still 500kB with VPN !) For 2) wireshark shows retransmitted packets, dup ack's, even out of order sometimes. I've tried playing with different /proc/sys/net/ipv4 parameters (tcp_rmem, window_scaling, tcp_congestion...) doesn't seem to make a difference. Update: Tried under windows 7 (no VPN) with some interesting results: tcp settings : default tcp_optimizer kernel.org : 10 kB/s 20 kB/s graphic-pc.com: 8 kB/s 70 kB/s ! tcp_optimizer turned on ctcp among other things. Have to check what os graphic-pc.com is running, my bet is linux's tcp_westwood and ms ctcp don't mix well here...

    Read the article

  • How does Subnetting Work?

    - by Kyle Brandt
    How does Subnetting Work, and How do you do it by hand or in your head? Can someone explain both conceptually and with several examples? Server Fault gets lots of subnetting homework questions, so we could use an answer to point them to on Server Fault itself. What is classless routing and why is class-based routing obsolete? If I have a network, how do I figure out how to split it up? If I am given a netmask, how do I know what the network Range is for it? Sometimes there is a slash followed by a number, what is that number? Sometimes there is a subnet mask, but also a wildcard mask, they seem like the same thing but they are different? Someone mentioned something about knowing binary for this? What is NAT (Network Address Translation). Not looking for links to other sites (unless maybe you have one post with a bunch of good ones). I already know how to subnet, I just thought it would be nice if Server Fault had a generic subnetting answer.

    Read the article

  • Ubuntu 12.04 partioning an external drive without lossing data

    - by Menelaos Perdikeas
    I have an Ubuntu 12.04 with an external 1.5T disk (just for data). It is /dev/sdc1 seen below: $ df -T Filesystem Type 1K-blocks Used Available Use% Mounted on /dev/sda1 ext4 1451144932 27722584 1350794536 3% / udev devtmpfs 6199460 4 6199456 1% /dev tmpfs tmpfs 2482692 988 2481704 1% /run none tmpfs 5120 0 5120 0% /run/lock none tmpfs 6206724 284 6206440 1% /run/shm /dev/sdc1 fuseblk 1465135100 172507664 1292627436 12% /media/Elements The thing is I would like to implement this rsync-based backup strategy and I want to use my /dev/sdc1 external drive for that. Since the guide mentioned above recommends placing the backup directory in a separate partition I want to repartition the /dev/sdc1 external hard disk but retain existing data in a separate partition. E.g. split /dev/sdc1 into two partitions: (i) one to be used exclusively for the rsync-based backup and (ii) the other for the existing miscellaneous data. How should I go about partitioning with minimal risk to my existing data and what kind of filesystem do you recommend? I would prefer a console-based guide but unfortunately all the material I found on the web is oriented towards partitioning the main (bootable) disk and not an external fuseblk filesystem used only for passive data.

    Read the article

  • Check for unique rows, but ignore one particular column

    - by user269148
    I have an XML document, that looks like this: Column A to S with headers, and there are 1922 rows. This is an backup of some SMS, and I want to get rid of duplicates. The problem is, that the Time in the readable_date header has been messed up. There is nothing wrong with the date, but the clock time is wrong, so I have split that column in three, with Year, day and clock. I know I can use a standard filter, but it only looks for unique rows in a single column. What I want to perform, is to make a row check similar to this: F(x)=Check if Column 2A to (infinate) is equal to Column 3A to (infinate), but ignore column(R). IF True, then delete Column 3A to (infinate) Otherwise Check IF column 2A to (infinate) is equal Column 4A to (infinate) and so on. I need to ignore a particular column in a row every time, and need to do this for a complete sheet. And the formula check should apply for every row, when the first one is done checking for duplicates... If anyone else has a better solution, please say so. Anyway, anyone who can help?

    Read the article

  • RAID degraded on Ubuntu server

    - by reano
    We're having a very weird issue at work. Our Ubuntu server has 6 drives, set up with RAID1 as follows: /dev/md0, consisting of: /dev/sda1 /dev/sdb1 /dev/md1, consisting of: /dev/sda2 /dev/sdb2 /dev/md2, consisting of: /dev/sda3 /dev/sdb3 /dev/md3, consisting of: /dev/sdc1 /dev/sdd1 /dev/md4, consisting of: /dev/sde1 /dev/sdf1 As you can see, md0, md1 and md2 all use the same 2 drives (split into 3 partitions). I also have to note that this is done via ubuntu software raid, not hardware raid. Today, the /md0 RAID1 array shows as degraded - it is missing the /dev/sdb1 drive. But since /dev/sdb1 is only a partition (and /dev/sdb2 and /dev/sdb3 are working fine), it's obviously not the drive that's gone AWOL, it seems the partition itself is missing. How is that even possible? And what could we do to fix it? My output of cat /proc/mdstat: Personalities : [linear] [multipath] [raid0] [raid1] [raid6] [raid5] [raid4] [raid10] md1 : active raid1 sda2[0] sdb2[1] 24006528 blocks super 1.2 [2/2] [UU] md2 : active raid1 sda3[0] sdb3[1] 1441268544 blocks super 1.2 [2/2] [UU] md0 : active raid1 sda1[0] 1464710976 blocks super 1.2 [2/1] [U_] md3 : active raid1 sdd1[1] sdc1[0] 2930133824 blocks super 1.2 [2/2] [UU] md4 : active raid1 sdf2[1] sde2[0] 2929939264 blocks super 1.2 [2/2] [UU] unused devices: <none> FYI: I tried the following: mdadm /dev/md0 --add /dev/sdb1 But got this error: mdadm: add new device failed for /dev/sdb1 as 2: Invalid argument Output of mdadm --detail /dev/md0 is: /dev/md0: Version : 1.2 Creation Time : Sat Dec 29 17:09:45 2012 Raid Level : raid1 Array Size : 1464710976 (1396.86 GiB 1499.86 GB) Used Dev Size : 1464710976 (1396.86 GiB 1499.86 GB) Raid Devices : 2 Total Devices : 1 Persistence : Superblock is persistent Update Time : Thu Nov 7 15:55:07 2013 State : clean, degraded Active Devices : 1 Working Devices : 1 Failed Devices : 0 Spare Devices : 0 Name : lia:0 (local to host lia) UUID : eb302d19:ff70c7bf:401d63af:ed042d59 Events : 26216 Number Major Minor RaidDevice State 0 8 1 0 active sync /dev/sda1 1 0 0 1 removed

    Read the article

  • At what point does the performance gap between GPU & CPU become so great that the CPU is holding back a system?

    - by Matthew Galloway
    I know that generally speaking for gaming performance the GPU is the primary factor which holds back performance, with everything else such as RAM/motherboard/PSU/CPU being secondary in importance to the graphics card. But at some point the other components ARE going to be significant in holding back the whole system! For instance nobody would be silly enough to play modern games with 512MB RAM and the very latest graphics cards (such as an HD7970) as I bet the performance increase over such a system with only 512MB but a mid range card would be non-existent! Thus it would be a "waste" for such a person to buy any high end graphics card without resolving first the system's other problems. The same point applies to other components, such as if it only had a Pentium II a current high end graphics card would be wasted on it! So my core question is how do you determine at what point for your system is spending on extra GPU power be completely "wasted"? (also, a slightly more nuanced question is trying work out at what point might the extra graphics power not be "wasted" but would be "sub optimal" value for money, when the expenditure should then be split around graphics card and other components. As obviously a gamer shouldn't always just spend on upgrading the graphics card! But needs to balance it out)

    Read the article

< Previous Page | 440 441 442 443 444 445 446 447 448 449 450 451  | Next Page >