Search Results

Search found 24240 results on 970 pages for 'asp net4 0'.

Page 446/970 | < Previous Page | 442 443 444 445 446 447 448 449 450 451 452 453  | Next Page >

  • How to break this string and sort on version number

    - by Sean P
    I have an ASP app that has a string array as such (there are much more than this): 7.5.0.17 Date: 05_03_10 7.5.0.18 Date: 05_03_10 7.5.0.19 Date: 05_04_10 7.5.0.2 Date: 02_19_10 7.5.0.20 Date: 05_06_10 7.5.0.3 Date: 02_26_10 7.5.0.4 Date: 03_02_10 7.5.0.5 Date: 03_08_10 7.5.0.6 Date: 03_12_10 7.5.0.7 Date: 03_19_10 7.5.0.8 Date: 03_25_10 7.5.0.9 Date: 03_26_10 7.5.1.0 Date: 05_06_10 How do I go about sorting these string by version descending?

    Read the article

  • How to build a search engine in C#

    - by Kumar
    I am trying to build a web application in ASP.NET MVC and need build a pretty complex search feature. When a user enters a search term I want to search a variety of data sources which include documents, tables in the database, webpage urls and some APIs like facebook. Any tips, tutorials and hints would be greatly appreciated.

    Read the article

  • ArgumentNullException when accessing a FormView instance

    - by David
    Background: I have an ASP.NET page which has a numebr of user controls within it. There are 2 user controls which are of interest. I need to display either one of them or neither of them, depending on the record selected previously. In the user controls I need to set properties of some controls which are in a FormView. So in my user control code-behind I have a number of properties which look something like this: Private ReadOnly Property phSectionReports() As PlaceHolder Get Return fvConfirmationReport.FindControl("phSectionReports") End Get End Property The problem: I am having problems with this Property. Sometimes it is returning Nothing/Null and sometimes it is throwing a NullArgumentException with the message "Value cannot be null. Parameter name: container". The exception is coming from trying to reference the fvConfirmationReport variable. fvConfirmationReport is the ID of my FormView in the page itself. So I am really after things to look for and if any ideas what sort of conditions (e.g stage in page cycle, etc.) might lead to this? An example stack trace is included below. ASP.NET 3.5 SP1, VB.NET Thanks, StackTrace: at System.Web.UI.DataBinder.GetPropertyValue(Object container, String propName) at System.Web.UI.WebControls.GridView.CreateChildControls(IEnumerable dataSource, Boolean dataBinding) at System.Web.UI.WebControls.CompositeDataBoundControl.PerformDataBinding(IEnumerable data) at System.Web.UI.WebControls.GridView.PerformDataBinding(IEnumerable data) at System.Web.UI.WebControls.DataBoundControl.OnDataSourceViewSelectCallback(IEnumerable data) at System.Web.UI.DataSourceView.Select(DataSourceSelectArguments arguments, DataSourceViewSelectCallback callback) at System.Web.UI.WebControls.DataBoundControl.PerformSelect() at System.Web.UI.WebControls.BaseDataBoundControl.DataBind() at System.Web.UI.WebControls.GridView.DataBind() at System.Web.UI.Control.DataBindChildren() at System.Web.UI.Control.DataBind(Boolean raiseOnDataBinding) ...snip... at System.Web.UI.Control.DataBind() at System.Web.UI.Control.DataBindChildren() at System.Web.UI.Control.DataBind(Boolean raiseOnDataBinding) at System.Web.UI.WebControls.FormView.CreateChildControls(IEnumerable dataSource, Boolean dataBinding) at System.Web.UI.WebControls.CompositeDataBoundControl.PerformDataBinding(IEnumerable data) at System.Web.UI.WebControls.FormView.PerformDataBinding(IEnumerable data) at System.Web.UI.WebControls.DataBoundControl.OnDataSourceViewSelectCallback(IEnumerable data) at System.Web.UI.DataSourceView.Select(DataSourceSelectArguments arguments, DataSourceViewSelectCallback callback) at System.Web.UI.WebControls.DataBoundControl.PerformSelect() at System.Web.UI.WebControls.BaseDataBoundControl.DataBind() at System.Web.UI.WebControls.FormView.DataBind() at System.Web.UI.WebControls.BaseDataBoundControl.EnsureDataBound() at System.Web.UI.WebControls.FormView.EnsureDataBound() at System.Web.UI.WebControls.CompositeDataBoundControl.CreateChildControls() at System.Web.UI.Control.EnsureChildControls() at System.Web.UI.Control.FindControl(String id, Int32 pathOffset) at System.Web.UI.Control.FindControl(String id) at App_UserControls_xxx_ucConfirmationForm.get_phSectionReports() in ucConfirmationForm.ascx.vb:line 343 at App_UserControls_xxx_ucConfirmationForm.Page_Load(Object sender, EventArgs e) in ucConfirmationForm.ascx.vb:line 412 at System.Web.UI.Control.OnLoad(EventArgs e) at System.Web.UI.Control.LoadRecursive() ...snip... at System.Web.UI.Control.LoadRecursive() at System.Web.UI.Page.ProcessRequestMain(Boolean includeStagesBeforeAsyncPoint, Boolean includeStagesAfterAsyncPoint)

    Read the article

  • How to create a setup for a web application with Web Platform Installer

    - by Nasser Hajloo
    I have a large Web Application ( ErPwith 11 subsystem) and I want tocreate a setup for itwith Microsoft WebPI. Currently We send our application for customers once a week (for weekly updates). We usefollowing tools in this application, So How to create a setup for out project toconfigure it in client IIS automatically List item .netFramework 3.5 SQL server 2008 Asp.net C# NHibernate Log4net castleProxy SQL Server Reporting Services (RDL) Visual Studio Client Reports (RDLC) Javascript JQuery

    Read the article

  • Why does Visual Studio sometimes add a number when creating page events in codebehinds?

    - by Kevin Pang
    When writing up a codebehind in Visual Studio for ASP.NET web forms applications, I often use the dropdowns at the top of the window to autogenerate page event handlers (e.g. Page_Load, Page_PreRender). I've noticed that sometimes Visual Studio likes to add numbers to these function names like "Page_Load1" or "Page_PreRender2". Programatically speaking, this has no effect on the code. But stylistically, I find it a bit ugly. Is there any way to get rid of this behavior?

    Read the article

  • ObjectDataSource typename of a singleton Business object

    - by luppi
    My singleton business object is defined in Global: public class Global : HttpApplication { public static BusinessForm BusinessFormLayer; void Application_Start(object sender, EventArgs e) { FormDalProvider concreteProvider = FormDalProvider.Instance; BusinessForumLayer = new BusinessForum(concreteProvider); } } My page: <asp:ObjectDataSource ID="objThreads" runat="server" SelectMethod="GetForms" SelectCountMethod="GetFormsCount" TypeName="Global.BusinessFormLayer" EnablePaging="true" SortParameterName="sortExpression">

    Read the article

  • simple jquery callback works on .net3.5 but nothing fires on .net 2.0?

    - by CliffC
    hi i have the following jquery postback method on the client <%@ Page Language="C#" AutoEventWireup="true" CodeFile="CallServerWithParameters.aspx.cs" Inherits="CallServerWithParameters" %> <!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd"> <html xmlns="http://www.w3.org/1999/xhtml"> <head runat="server"> <title></title> <script src="jquery-1.2.6.js" type="text/javascript"></script> <script language="javascript"> $(document).ready(function() { $("#txtNoOfMales").change(function() { var ticketRequired = this.value; var options = { type: "POST", url: "CallServerWithParameters.aspx/GetAvailableTicketsForMales", data: "{no:'" + ticketRequired + "'}", contentType: "application/json; charset=utf-8", dataType: "json", success: function(response) { if (response.d != "") { alert(response.d); $("#txtNoOfMales").focus(); } } }; //Call the PageMethods $.ajax(options); }); }); </script> </head> <body> <form id="form1" runat="server"> <div> No of Male Tickets:<asp:TextBox ID="txtNoOfMales" runat="server"></asp:TextBox> </div> </form> </body> </html> and the following web method on the server side using System; using System.Collections.Generic; using System.Web; using System.Web.UI; using System.Web.UI.WebControls; using System.Web.Services; public partial class CallServerWithParameters : System.Web.UI.Page { protected void Page_Load(object sender, EventArgs e) { } [WebMethod] public static string GetAvailableTicketsForMales(int no) { string result = ""; int NoOfTicketsAvailable = 5; if (no > NoOfTicketsAvailable) { result = "Only " + NoOfTicketsAvailable.ToString() + " Male ticket(s) avaialable. Please eneter a lower number!"; } return result; } } problem is everything works fine on .net 3.5 but if i use the same code on .net 2.0 the webmethod event does not get call at all, anybody have any idea what i did wrong? thanks updated with full source code

    Read the article

  • Get remote image dimensions

    - by o-logn
    Given a URL to an image (and not the image itself), what's the most efficient of getting it's dimensions? I would like to change the height and width attributes in the image tag (<img>) if it is greater than 200x200. However, if it's smaller than that, then I'd like to keep the size as it is. (I'm using ASP.NET/C#)

    Read the article

  • How to automate database updates at webserver

    - by user221919
    hi I am developing the online bidding system using asp.net where I need to close the auction if the auction time is get closed without any bid. As in the following web site : http://www.bidrivals.com/us/ Please help me to resolve to this problem. Waiting for your valuable thoughts. Thanking You.

    Read the article

  • Problem wth paging ObjectDataSource

    - by funky
    asp page code: <asp:ObjectDataSource runat="server" ID="odsResults" OnSelecting="odsResults_Selecting" /> <tr><td> <wssawc:SPGridViewPager ID="sgvpPagerTop" runat="server" GridViewId="sgvConversionResults" /> </td></tr> <tr> <td colspan="2" class="ms-vb"> <wssawc:SPGridView runat="server" ID="sgvConversionResults" AutoGenerateColumns="false" RowStyle-CssClass="" AlternatingRowStyle-CssClass="ms-alternating" /> </td> </tr> Class code: public partial class Convert : System.Web.UI.Page { ... private DataTable resultDataSource = new DataTable(); ... protected void Page_Init(object sender, EventArgs e) { ... resultDataSource.Columns.Add("Column1"); resultDataSource.Columns.Add("Column2"); resultDataSource.Columns.Add("Column3"); resultDataSource.Columns.Add("Column4"); ... odsResults.TypeName = GetType().AssemblyQualifiedName; odsResults.SelectMethod = "SelectData"; odsResults.SelectCountMethod = "GetRecordCount"; odsResults.EnablePaging = true; sgvConversionResults.DataSourceID = odsResults.ID; ConversionResultsCreateColumns(); sgvConversionResults.AllowPaging = true; ... } protected void btnBTN_Click(object sender, EventArgs e) { // add rows into resultDataSource } public DataTable SelectData(DataTable ds,int startRowIndex,int maximumRows) { DataTable dt = new DataTable(); dt.Columns.Add("Column1"); dt.Columns.Add("Column2"); dt.Columns.Add("Column3"); dt.Columns.Add("Column4"); for (int i =startRowIndex; i<startRowIndex+10 ;i++) { if (i<ds.Rows.Count) { dt.Rows.Add(ds.Rows[i][0].ToString(), ds.Rows[i][1].ToString(), ds.Rows[i][2].ToString(), ds.Rows[i][3].ToString()); } } return dt; } public int GetRecordCount(DataTable ds) { return ds.Rows.Count; } protected void odsResults_Selecting(object sender, ObjectDataSourceSelectingEventArgs e) { e.InputParameters["ds"] = resultDataSource; } } On click BTN button resultDataSource receive some rows. Page reload and we can see result in sgvConversionResults. First 10 rows. But after click next page in pager we have message "There are no items to show in this view". When I try debug I find that after postBack page (on click next page) input params "ds" is blank, ds.Rows.Count = 0 and etc... As though resultDataSource became empty(( What do I do not correctly?. Sorry my English.

    Read the article

  • Forms authentication failed for the request. Reason: The ticket supplied has expired.

    - by Max Toro
    My event log is flooded with this message: Forms authentication failed for the request. Reason: The ticket supplied has expired. I think this happens when people timeout instead of logout. First of all , this is not an error, it's Type: Information I don't want this information, how do I stop ASP.NET from logging it? My application is not web-farmed, and uses a static machine key.

    Read the article

  • Appending javascript code piece to the end of the body tag

    - by uzay95
    I am looking for a way to insert javascript code block to end of ASP.NET page. Page.ClientScript.RegisterClientScriptBlock(typeof(Page), "showVideo", sScript, true); is appending to body but js codes are always requesting some js files didn't load or some functions are below of the script. How can i append scripts that i generated dynamically to the bottom of body? Thanks for your help.

    Read the article

  • HTTP HEAD Request and System.Web.Mvc.FileResult

    - by mnero0429
    I'm using BITS to make requests to a ASP.NET MVC controller method named Source that returns a FileResult. I know the type FilePathResult uses HttpResponse.TransmitFile, but I don't know if HttpResponse.TransmitFile actually writes the file to the response stream regardless of the request type. My question is, does FileResult only include the header information on HEAD requests, or does it transmit the file regardless of the request type? Or, do I have to account for HEAD requests myself?

    Read the article

  • GridView paging inside an UpdatePanel or PlaceHolder components

    - by John
    Hello, I'm new to ASP.NET. Im developing ASP.NET C# web form which creating GridView components dynamically and filling them using the data received from my webservice. I'm creating these GridView components programmatically in server-side (cs file)- it has to be flexible - 1 GridView and sometimes 10 GridView components. The problem occurs when I'm trying to add pagination - whenever the user clicks the "next" page, the whole page is getting refreshed because of a postBack and I'm loosing all my data and the page returns Blank/Empty. I used PlaceHolder to hold the GridView components, while searching for a solution, I found UpdatePanel as a better alternative - as far as I understand the page can be partially refreshed - which means that only the UpdatePanel has to be refreshed...but it doesn't work. The following code sample is my TEST, the UpdatePanel is the only component initiated in the client side (aspx page), the rest initiated programmatically in CS. how can I solve the issue described above? Why does the whole page is getting refreshed and I'm loosing my data? can you recommend another way? can provide me with any code sample? If I'm not rebuilding the GridView, it doesn't work... Here is my Default.aspx.cs: public partial class TestAjaxForm : System.Web.UI.Page { DataTable table; protected void Page_Load(object sender, EventArgs e) { if (!IsPostBack) bindGridView(); } public void bindGridView() { GridView gridView1 = new GridView(); gridView1.AutoGenerateColumns = true; gridView1.PageSize = 2; gridView1.AllowPaging = true; gridView1.PagerSettings.Mode = PagerButtons.Numeric; gridView1.PagerSettings.Position = PagerPosition.Bottom; gridView1.PagerSettings.PageButtonCount = 10; gridView1.PageIndexChanging += new GridViewPageEventHandler(this.GridView1_PageIndexChanging); table = new DataTable(); table.Columns.Add("FirstName"); table.Columns.Add("LastName"); DataRow row = table.NewRow(); row["FirstName"] = "John"; row["LastName"] = "Johnoson"; table.Rows.Add(row); row = table.NewRow(); row["FirstName"] = "Johnny"; row["LastName"] = "Marley"; table.Rows.Add(row); row = table.NewRow(); row["FirstName"] = "Kate"; row["LastName"] = "Li"; table.Rows.Add(row); panel.ContentTemplateContainer.Controls.Add(gridView1); gridView1.DataSource = table; gridView1.DataBind(); } protected void GridView1_PageIndexChanging(object sender, GridViewPageEventArgs e) { GridView gridView1 = (GridView)sender; gridView1.PageIndex = e.NewPageIndex; gridView1.DataSource = table; gridView1.DataBind(); } } Please help me, Thank you.

    Read the article

  • Cannot find typenames ("cannot resolve symbol")

    - by dotnetdev
    I have a site in ASP.NET using Telerik AJAX controls. Despite the latest binary being added to the website project, my code (eg myRadGrid.Datasource = "";) shows a red line on type names as they cannot be found for some reason. Can anyone possibly explain why or have experience in this sort of problem? Thanks

    Read the article

  • Multiple row Tabs using CSS

    - by Jack
    Hello, i can't find a way to do multiple row tabs with ASP.net ajax tab control. I also can't find a tutorial or example on using CSS to make multiple row of tabs. In case you don't understand what i'm looking for here is a image of what i'm looking for http://bp1.blogger.com/_WCGCQYWEaxs/Rq1c2bLNMDI/AAAAAAAAABU/0sKw_CrKLL4/s1600-h/dsd.jpg Can someone give me a link on how to achieve multiple row of tabs?

    Read the article

  • how to do iis 7 url rewrite to avoid processing static html file requests for an aspnet mvc applicat

    - by ROHITH
    currently i am developing an aspnet mvc application on iis 5.5.So i have given wild card mapping.I know if we give wild card mapping ,all request go through the asp.net execution pipeline pipeline.(correct me if i am wrong).and in iis7 or above ,we have in built url rewrite engine.What i want to know,in iis7 or above will a request to static html page will go through the aspnet mvc execution pipeline?

    Read the article

< Previous Page | 442 443 444 445 446 447 448 449 450 451 452 453  | Next Page >