Search Results

Search found 12488 results on 500 pages for 'hardware upgrade'.

Page 466/500 | < Previous Page | 462 463 464 465 466 467 468 469 470 471 472 473  | Next Page >

  • Exchange Server 2007 Setup

    - by AlamedaDad
    Hi, I'm working on a upgrade to Exchange 2007 and I wanted to get some advise on hardware choices. We currently have an Exchange 2003 STD server with 400 users split between 6 AD Sites, that is housed on a single server. We need to move to a redundant, fault tolerant system to support our users. I'm planning on installing 2 Dell 1950 servers with W2k8-std to act as CAS and Hub servers, with NLB to allow abstraction of the actual server name to the users. There won't be an edge system since we have a Barracuda box already that will handle in/out spam/virus filtering. Backend I'm planning on 2 mailbox servers which will be Dell 2950s with 16GB RAM, 2 either dual-core or quad-core CPUs and 6 300GB SAS drives in some RAID config. These systems will be clustered using W2k8 Ent clustering and running CCR in Exchange. My questions are as follows: Is 16GB enough RAM for serving that many mailboxes along with the windows clustering and ccr? I'm trying to figure out disk layouts and I'm unsure of whether to use all local disk or some local and some SAN, via an OpenFiler iSCSI server. The SAN would be a Dell 2850 with 6 - 300GB SCSI drives and a PERC controller to slice as I want, with 8GB RAM. Option 1: 2 drives, RAID 1 - OS 2 drives, RAID 1 - Logs 2 drives, RAID 1 - Mail stores Option 2: 2 drives, RAID 1 - OS and logs 4 drives, RAID 5 - Mail Stores and scratch space for eseutil. Option 3: 2 drives, RAID 1 - OS 2 drives, RAID 1 - Logs 2 drives, RAID 0 - scratch space ~300GB iSCSI volume for mail stores Option 4: 2 drives, RAID 1 - OS 4 drives, RAID 5 - scratch space ~300GB iSCSI volume for mail stores ~300GB iSCSI volume for logs I have 2 sockets for CPUs and need to chose between dual and quad cores. The dual core have faster clocks but less cache and I'm thinking older architecture. Am I better off with more cores and cache while sacraficing clock speed? I am planning on adding the new E2K7 cluster to the E2K3 server and then move each mailbox over, all at once, then remove the old server. This seems more complicated than simply getting rid of the 2003 server and then adding the 2007 cluster and restoring the mailboxes using PowerControls or exmerge. The migration option lets me do this on my time, where a cutover means it all needs to work at once. If I go with the cutover method, how can I prebuild the servers and add them to the domain right after removing the 2003 server, or can't I? I think the answer is no and the migration is my only real option if I want to prebuild. I need to also migrate about 30GB of Public Folders. Is there anything special about this, other than specifying in the E2K7 install that I want older Outlook clients and PF's setup? I guess I could even keep the E2K3 server to host just the PFs? Lastly, if I have a mix of Outlook 200, 2003 and 2007 what do I need to do to make sure they all have access to the GAL and OAB? At time of cutover, we'll be at like 90% 2007, but we will have some older stuff around. My plan is to use Outlook Anywhere on laptops that are used outside the physical network. Are there any gotchas involved in that? I'm even thinking about using is for all Outlook clients, does anyone do that? The reason I'm considering it is that our WAN is really VPN tunnels over internet connections, so not a fully messhed, stable WAN. Thank you all very much for the assistance in advance and I look forward to discussion of these points! Regards...Michael

    Read the article

  • Graphics driver for ubuntu on dell latitude XT

    - by marc.riera
    we have a laptop (dell latitude xt) on our company, and we would like to install ubuntu on it. windows 7 works fine out of the box, so the hardware is fine. since this laptop has a touchscreen we just installed ubuntu 10.10 netbook edition 32x. But, we do not manage to enable the touchscreen, neither the vga graphic drivers. this is the output from lspci, if somebody cares. 00:00.0 Host bridge: ATI Technologies Inc Radeon Xpress 7930 Host Bridge 00:01.0 PCI bridge: ATI Technologies Inc RS7932 PCI Bridge 00:04.0 PCI bridge: ATI Technologies Inc Device 7934 00:06.0 PCI bridge: ATI Technologies Inc RS7936 PCI Bridge 00:07.0 PCI bridge: ATI Technologies Inc Device 7937 00:13.0 USB Controller: ATI Technologies Inc SB600 USB (OHCI0) 00:13.1 USB Controller: ATI Technologies Inc SB600 USB (OHCI1) 00:13.2 USB Controller: ATI Technologies Inc SB600 USB (OHCI2) 00:13.3 USB Controller: ATI Technologies Inc SB600 USB (OHCI3) 00:13.4 USB Controller: ATI Technologies Inc SB600 USB (OHCI4) 00:13.5 USB Controller: ATI Technologies Inc SB600 USB Controller (EHCI) 00:14.0 SMBus: ATI Technologies Inc SBx00 SMBus Controller (rev 14) 00:14.1 IDE interface: ATI Technologies Inc SB600 IDE 00:14.2 Audio device: ATI Technologies Inc SBx00 Azalia (Intel HDA) 00:14.3 ISA bridge: ATI Technologies Inc SB600 PCI to LPC Bridge 00:14.4 PCI bridge: ATI Technologies Inc SBx00 PCI to PCI Bridge 01:05.0 VGA compatible controller: ATI Technologies Inc Radeon Xpress 1250 03:01.0 CardBus bridge: Texas Instruments PCIxx12 Cardbus Controller 03:01.1 FireWire (IEEE 1394): Texas Instruments PCIxx12 OHCI Compliant IEEE 1394 Host Controller 03:01.3 SD Host controller: Texas Instruments PCIxx12 SDA Standard Compliant SD Host Controller 09:00.0 Ethernet controller: Broadcom Corporation NetXtreme BCM5756ME Gigabit Ethernet PCI Express 0b:00.0 Network controller: Broadcom Corporation BCM4321 802.11a/b/g/n (rev 03) I've tryied to install ati drivers 9.3 , which I downloaded and installed, unpacked and installed, builded and installed, but nothing worked. Looks like the latests version is just accepted to work on jaunty 9.04, so they are kind of old. what else I can do? thanks. Marc Information added: lsusb and lspci -n |grep 01:05.0 sysop@wl083517:~$ lspci -n |grep 01:05.0 01:05.0 0300: 1002:7942 sysop@wl083517:~$ lsusb Bus 006 Device 002: ID 413c:8138 Dell Computer Corp. Wireless 5520 Voda I Mobile Broadband (3G HSDPA) Minicard EAP-SIM Port Bus 006 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 005 Device 002: ID 413c:8140 Dell Computer Corp. Wireless 360 Bluetooth Bus 005 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 004 Device 002: ID 0483:2016 SGS Thomson Microelectronics Fingerprint Reader Bus 004 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 003 Device 002: ID 1b96:0001 N-Trig Duosense Transparent Electromagnetic Digitizer Bus 003 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 002 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 001 Device 002: ID 03f0:1807 Hewlett-Packard Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub sysop@wl083517:~$

    Read the article

  • external hard drive is no longer recognized, gives buffer I/O errors

    - by BioGeek
    Hi all, The external hard drive which contains all my photos and where I backed-up all my important documents is no longer recognized. It is a three month old 500GB Iomage Prestige Desktop Hard Drive. When I plug it in, it is recognised as a USB device, because it shows up when I type lsusb, but dmesg gives this error message. [19712.013250] usb 2-2: new high speed USB device using ehci_hcd and address 21 [19712.145347] usb 2-2: configuration #1 chosen from 1 choice [19712.147214] scsi25 : SCSI emulation for USB Mass Storage devices [19712.147514] usb-storage: device found at 21 [19712.147519] usb-storage: waiting for device to settle before scanning [19717.148978] usb-storage: device scan complete [19717.149527] scsi 25:0:0:0: Direct-Access ST350082 0AS PQ: 0 ANSI: 2 CCS [19717.151020] sd 25:0:0:0: Attached scsi generic sg2 type 0 [19717.151685] sd 25:0:0:0: [sdb] 976773168 512-byte logical blocks: (500 GB/465 GiB) [19717.160402] sd 25:0:0:0: [sdb] Write Protect is off [19717.160412] sd 25:0:0:0: [sdb] Mode Sense: 34 00 00 00 [19717.160418] sd 25:0:0:0: [sdb] Assuming drive cache: write through [19717.165685] sd 25:0:0:0: [sdb] Assuming drive cache: write through [19717.165691] sdb: sdb1 [19719.171808] sd 25:0:0:0: [sdb] Assuming drive cache: write through [19719.171818] sd 25:0:0:0: [sdb] Attached SCSI disk [19737.430998] sd 25:0:0:0: [sdb] Unhandled sense code [19737.431007] sd 25:0:0:0: [sdb] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE [19737.431016] sd 25:0:0:0: [sdb] Sense Key : Medium Error [current] [19737.431027] sd 25:0:0:0: [sdb] Add. Sense: Unrecovered read error [19737.431038] end_request: I/O error, dev sdb, sector 6160463 [19737.431050] Buffer I/O error on device sdb1, logical block 6160400 [19737.431060] Buffer I/O error on device sdb1, logical block 6160401 [19737.431067] Buffer I/O error on device sdb1, logical block 6160402 [19737.431075] Buffer I/O error on device sdb1, logical block 6160403 [19737.431082] Buffer I/O error on device sdb1, logical block 6160404 [19737.431088] Buffer I/O error on device sdb1, logical block 6160405 [19737.431096] Buffer I/O error on device sdb1, logical block 6160406 [19737.431102] Buffer I/O error on device sdb1, logical block 6160407 [19737.431114] Buffer I/O error on device sdb1, logical block 6160408 [19737.431121] Buffer I/O error on device sdb1, logical block 6160409 [19737.712183] sd 6:0:0:0: [sdb] Unhandled sense code [19737.712191] sd 6:0:0:0: [sdb] Result: hostbyte=DID_ERROR driverbyte=DRIVER_SENSE [19737.712200] sd 6:0:0:0: [sdb] Sense Key : Hardware Error [current] [19737.712210] sd 6:0:0:0: [sdb] Add. Sense: No additional sense information [19737.712222] end_request: I/O error, dev sdb, sector 0 [19737.712232] Buffer I/O error on device sdb, logical block 0 Neither does the external drive show when I use fdisk: jeroen@phalacrocorax:~$ sudo fdisk -l [sudo] password for jeroen: Disk /dev/sda: 160.0 GB, 160041885696 bytes 255 heads, 63 sectors/track, 19457 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes Disk identifier: 0x000341ad Device Boot Start End Blocks Id System /dev/sda1 * 1 18714 150320173+ 83 Linux /dev/sda2 18715 19457 5968147+ 5 Extended /dev/sda5 18715 19457 5968116 82 Linux swap / Solaris` I popped the disk out of the casing put it on a SATA connect internally and then tried the file recovery programs testdisk/photorec and SpinRite, but both failed because they couldn't recognize the external harddisk. Do I have any other options?

    Read the article

  • Connecting a 2560x1440 display to a laptop?

    - by tjollans
    Having read Jeff Atwood's blog post on Korean 27" IPS LCDs, I've been wondering to what extent these are useful in a notebook + large display situation. I own a Lenovo Thinkpad Edge E320 with 2nd gen. integrated Intel graphics. According to the spec from Intel, this should support HDMI version 1.4, and, using DisplayPort, resolutions up to 2560x1600. HDMI version 1.4 supports resolutions up to 4096×2160, however, according to c't (German), the HDMI interface used with Intel chips only supports 1920x1200. The same goes for the DVI output - dual-link DVI-D, apparently, is not supported by Intel. It would appear that my laptop cannot digitally drive this kind of resolution. Now what about other laptops? According to the article in c't above, AMD's integrated graphics chips have the same limitation as Intel's. NVIDIA graphics cards, apparently, only offer resolutions up to 1900x1200 over HDMI out of the box, but it's possible, when using Linux at least, to trick the driver into enabling higher resolutions. Is this still true? What's the situation on Windows and OSX? I found no information on whether discrete AMD chips support ultra-high resolutions over HDMI. Owners of laptops with (Mini) DisplayPort / Thunderbolt won't have any issues with displays this large, but if you're planning to go for a display with dual-link DVI-D input only (like the Korean ones), you're going to need an adapter, which will set you back something like €70-€100 (since the protocols are incompatible). The big question mark in this equation is VGA: a lot of laptops have it, and I don't see any reason to think this resolution is not supported by the hardware (an oft-quoted figure appears to be 2048x1536@75Hz, so 2560x1440@60Hz should be possible, right?), but are the drivers likely to cause problems? Perhaps more critically, you'd need a VGA to dual-link DVI-D adapter that converts analog to digital signals. Do these exist? How good are they? How expensive are they? Is there a performance penalty involved? Please correct me if I'm wrong on any points. In summary, what are the requirements on a laptop to drive an external LCD at 2560x1440, in particular one that supports dual-link DVI-D only, and what tools and adapters can be used to lower the bar?

    Read the article

  • High Jitter in NTP and poll value never goes above 128

    - by Aseem
    I have a lot of servers syncing to the same NTP servers (4). Not every server is in the same LAN. Some are 3 hops away from the NTP servers and some are 6 hops away. On couple of servers I see that the poll value never touches the 1024 mark and the jitter value is in double digits. Could it be due to the system hardware? These are windows servers (physical) and require as accurate time as possible. Please advice what I should do. Some of the stats that I collected manually from the bad box (which is 6 hops away from the ntp servers) C:\Program Files (x86)\NTP>ntpq -p -n remote refid st t when poll reach delay offset jitter ============================================================================== +*.*.*.25 *.*.*.233 2 u 12 128 377 1.210 -12.579 14.913 +*.*.*.26 *.*.*.233 2 u 96 128 377 1.067 -2.235 9.885 **.*.*.27 *.*.*.233 2 u 24 128 377 1.038 -7.569 11.178 +*.*.*.28 *.*.*.233 2 u 49 128 377 1.288 -11.058 14.544 remote refid st t when poll reach delay offset jitter ============================================================================== +*.*.*.25 *.*.*.233 2 u 124 128 377 0.614 -6.212 5.329 +*.*.*.26 *.*.*.233 2 u 93 128 377 0.910 -9.431 3.111 +*.*.*.27 *.*.*.233 2 u 1 128 377 0.824 -7.428 3.129 **.*.*.28 *.*.*.233 2 u 84 128 377 1.503 -8.230 3.511 remote refid st t when poll reach delay offset jitter ============================================================================== **.*.*.25 *.*.*.233 2 u 117 128 377 1.235 -4.084 11.405 +*.*.*.26 *.*.*.233 2 u 96 128 377 1.335 -11.813 13.130 +*.*.*.27 *.*.*.233 2 u 130 128 377 1.549 -14.036 16.381 -*.*.*.28 *.*.*.233 2 u 79 128 377 1.258 13.395 22.203 remote refid st t when poll reach delay offset jitter ============================================================================== **.*.*.25 *.*.*.233 2 u 88 128 377 1.235 -4.084 14.068 +*.*.*.26 *.*.*.233 2 u 63 128 377 1.335 -11.813 17.086 +*.*.*.27 *.*.*.233 2 u 103 128 377 1.549 -14.036 20.691 -*.*.*.28 *.*.*.233 2 u 47 128 377 1.258 13.395 20.231 remote refid st t when poll reach delay offset jitter ============================================================================== +*.*.*.25 *.*.*.233 2 u 47 64 377 0.652 -15.805 14.077 **.*.*.26 *.*.*.233 2 u 11 64 377 1.013 -14.423 11.375 -*.*.*.27 *.*.*.233 2 u 63 64 377 0.765 -2.030 7.680 +*.*.*.28 *.*.*.233 2 u 4 64 377 1.191 -17.980 14.393 remote refid st t when poll reach delay offset jitter ============================================================================== -*.*.*.25 *.*.*.233 2 u 3 128 377 1.576 18.665 21.999 +*.*.*.26 *.*.*.233 2 u 73 128 377 0.637 -5.012 14.405 **.*.*.27 *.*.*.233 2 u 127 128 377 0.272 -8.237 14.438 +*.*.*.28 *.*.*.233 2 u 123 128 377 1.190 -14.383 18.875 C:\Program Files (x86)\NTP>ntpdc -c loopinfo offset: -0.016430 s frequency: 7.106 ppm poll adjust: 18 watchdog timer: 133 s offset: -0.016430 s frequency: 7.106 ppm poll adjust: 18 watchdog timer: 341 s offset: -0.000149 s frequency: 6.645 ppm poll adjust: 0 watchdog timer: 383 s offset: 0.015735 s frequency: 6.725 ppm poll adjust: 7 watchdog timer: 577 s offset: -0.010331 s frequency: 6.748 ppm poll adjust: 21 watchdog timer: 567 s offset: -0.009427 s frequency: 6.687 ppm poll adjust: 28 watchdog timer: 301 s offset: -0.007361 s frequency: 6.612 ppm poll adjust: 30 watchdog timer: 155 s offset: -0.008106 s frequency: 4.358 ppm poll adjust: 30 watchdog timer: 291 s NTP.conf # NTP configuration file # Use drift file driftfile "C:\Program Files (x86)\NTP\ntp.drift" # Logs statistics loopstats peerstats clockstats statsdir "C:\Program Files (x86)\NTP\logs\" # directory for statistics files filegen peerstats file peerstats type day enable filegen loopstats file loopstats type day enable filegen clockstats file clockstats type day enable logfile "C:\Program Files (x86)\NTP\logs\syslog.txt" # Use specific NTP servers server *.*.*.25 minpoll 4 maxpoll 7 iburst server *.*.*.26 minpoll 4 maxpoll 7 iburst server *.*.*.27 minpoll 4 maxpoll 7 iburst server *.*.*.28 minpoll 4 maxpoll 7 iburst

    Read the article

  • SAS Expanders vs Direct Attached (SAS)?

    - by jemmille
    I have a storage unit with 2 backplanes. One backplane holds 24 disks, one backplane holds 12 disks. Each backplane is independently connected to a SFF-8087 port (4 channel/12Gbit) to the raid card. Here is where my question really comes in. Can or how easily can a backplane be overloaded? All the disks in the machine are WD RE4 WD1003FBYX (black) drives that have average writes at 115MB/sec and average read of 125 MB/sec I know things would vary based on the raid or filesystem we put on top of that but it seems to be that a 24 disk backplane with only one SFF-8087 connector should be able to overload the bus to a point that might actually slow it down? Based on my math, if I had a RAID0 across all 24 disks and asked for a large file, I should, in theory should get 24*115 MB/sec wich translates to 22.08 GBit/sec of total throughput. Either I'm confused or this backplane is horribly designed, at least in a perfomance environment. I'm looking at switching to a model where each drive has it's own channel from the backplane (and new HBA's or raid card). EDIT: more details We have used both pure linux (centos), open solaris, software raid, hardware raid, EXT3/4, ZFS. Here are some examples using bonnie++ 4 Disk RAID-0, ZFS WRITE CPU RE-WRITE CPU READ CPU RND-SEEKS 194MB/s 19% 92MB/s 11% 200MB/s 8% 310/sec 194MB/s 19% 93MB/s 11% 201MB/s 8% 312/sec --------- ---- --------- ---- --------- ---- --------- 389MB/s 19% 186MB/s 11% 402MB/s 8% 311/sec 8 Disk RAID-0, ZFS WRITE CPU RE-WRITE CPU READ CPU RND-SEEKS 324MB/s 32% 164MB/s 19% 346MB/s 13% 466/sec 324MB/s 32% 164MB/s 19% 348MB/s 14% 465/sec --------- ---- --------- ---- --------- ---- --------- 648MB/s 32% 328MB/s 19% 694MB/s 13% 465/sec 12 Disk RAID-0, ZFS WRITE CPU RE-WRITE CPU READ CPU RND-SEEKS 377MB/s 38% 191MB/s 22% 429MB/s 17% 537/sec 376MB/s 38% 191MB/s 22% 427MB/s 17% 546/sec --------- ---- --------- ---- --------- ---- --------- 753MB/s 38% 382MB/s 22% 857MB/s 17% 541/sec Now 16 Disk RAID-0, it's gets interesting WRITE CPU RE-WRITE CPU READ CPU RND-SEEKS 359MB/s 34% 186MB/s 22% 407MB/s 18% 1397/sec 358MB/s 33% 186MB/s 22% 407MB/s 18% 1340/sec --------- ---- --------- ---- --------- ---- --------- 717MB/s 33% 373MB/s 22% 814MB/s 18% 1368/sec 20 Disk RAID-0, ZFS WRITE CPU RE-WRITE CPU READ CPU RND-SEEKS 371MB/s 37% 188MB/s 22% 450MB/s 19% 775/sec 370MB/s 37% 188MB/s 22% 447MB/s 19% 797/sec --------- ---- --------- ---- --------- ---- --------- 741MB/s 37% 376MB/s 22% 898MB/s 19% 786/sec 24 Disk RAID-1, ZFS WRITE CPU RE-WRITE CPU READ CPU RND-SEEKS 347MB/s 34% 193MB/s 22% 447MB/s 19% 907/sec 347MB/s 34% 192MB/s 23% 446MB/s 19% 933/sec --------- ---- --------- ---- --------- ---- --------- 694MB/s 34% 386MB/s 22% 894MB/s 19% 920/sec 28 Disk RAID-0, ZFS 32 Disk RAID-0, ZFS 36 Disk RAID-0, ZFS More details: Here is the exact unit: http://www.supermicro.com/products/chassis/4U/847/SC847E1-R1400U.cfm

    Read the article

  • 2 Servers setup for redundency, backup

    - by minal
    I presently have 1 dedicated virtual server running my website/blog/mail, etc. This is on Hyper-V with 512MB RAM. Windows Web2008. With the VM, I have these running within it: SmarterMail – for emails MS DNS – I have my own nameservers on this server SQL Express IIS7 2 IP Address I have now leased 2 physical servers : P4 2.6Ghz 1GB RAM 80GB HDD. With these new servers, I get 2 IPs per server as well. These are running Windows 2008 Standard. With the VM the HDD was obviously on a RAID setup so I was not worried about hardware issues as it fell on the provider to manage. However, with the new servers the HDD is not RAID’d, hence my concern is that if it fails I need a backup position. What would be the most ideal setup to go for? I am thinking: Server 1: (Web/PrimaryDNS) DNS – NS1 SQL Express – OFF turn on when required, ie. Server2 is down SmarterMail – OFF turn on when required, ie. Server2 is down IIS 7 Server2:(SQL/Backup) DNS – NS2 SQL Web Edition SmarterMail IIS 7 How can I set it up so that if 1 goes down I can have everything on 2 instantly or by manual switching over. I am confused as other DNS servers will cache the web servers IP address for requests, and if that server goes down, the backup server will have a different IP. How do I make this work? I will be doing routine backups, in which case I will keep copies of backups on both servers. If I am copying the same stuff on both servers like a mirror then I am losing on using the true performance out of it. It's like 1 server is always on standby. Ideally I want SQL and web on 2 diff machines for best performance. If Server1 goes down, I should be able to switch to Server2 fairly easily. I don't have a problem with manual intervention to start the sql/mail services, etc. In terms of scalabilty, the VM has coped pretty well to date. Moving forward the SQL and IIS workload is going to double pretty quickly. Some ideas would be great.

    Read the article

  • Certain clients (IP range) can not ping server

    - by Logman
    I just virtualized a Windows 2003 Server SP2 x32. The server contained our help desk server (Spiceworks) and our anti virus management server (ESET RAC). The host computer actually contained the virtualized server originally; I created the vhd and then I wiped this system clean and installed Windows 2008 R2 x64 Datacenter and added the virtualized 2003 onto the Hyper-V 2008 R2 Server. I got the server running fine except for... certain ip ranges. Local clients can get updates from the AV server from my 192.168.180.xxx & 192.168.181.xxx BUT NOT from any 192.168.182.xxx, 192.168.183.xxx, 192.168.184.xxx etc... I can not ping the server from any clients except for the 180. & 181. ranges. Now I created 2 other virtualized servers (win2008 & a win7 pro) and they exist on the same virtual host as the 2003 server. And at first I could not ping those until I went to the "\Network and Sharing Center\Advanced sharing settings" and Turned On File and Print Sharing. Then I could ping and access those virtualized guests. Win2003 server isn't quite the same. But I am sure I have it on. But now when I ping from a client on one of those ranges that would not work I get this: As you can see the ping leaves our network. We have 2 ad/dns servers (one 180. & the other in the 181. range). Is it DNS? Both AD/DNS servers are Windows 2003. And we plan on upgrading both to 2008 R2 within a month or two but I need to fix this issue pronto (esp the AV end). btw, I did rename that 2003 Server (Spiceworks/AV) hostname. And I tried a CNAME. But I do not think that is the problem. EDIT: OR because this server existed on this hardware/computer before becoming virtualized?

    Read the article

  • I cut-to-move DCIM folder to ext SD when an auto android OS update popped up b4 I could choose target - Cannot recover 200+ photos

    - by ZeroG
    I was downloading my Exhibit II's DCIM camera folder (with month's of photos inside) to its external SD card, in order to transfer them into my laptop. In my overconfidence, I hurriedly chose cut-to-move (rather than copy-to-move) when KABOOM! —an automatic Android OS update popped up before I could choose the target!!! I figured everything was in cache & calmly tried to go through with the update. But that was not a typically seamless event. It showed downloading icon but hmm… since I rooted the phone it brought the command line up & recovery sequence. But neither Android nor I had yet downloaded any alternate custom ROM Files to internal SD to update from! So were they trying to make me unroot my phone by giving me some bogus update on the fly or just give me a hard time in trying to hand me down an unrooted ROM that I'd have to figure out how to root again? Yes, I know there was that blurb about overwriting a file of the same name but I was trying to shake the darn stubborn update being forced on my phone during this precarious moment. I thought I had frozen or turned off all those auto-updates previously. Anyway, phones are small & fingers are big (sigh)... I tried to reboot into safe mode but the resultant photo file was partially overwritten (200 files had names but Zero bytes in them). I thought maybe it was still hung in cache or deposited somewhere else but I have searched everywhere with file managers. Since I did not have Titanium backing up camera, photo folder or gallery, I cannot recover 200+ photos. Dumb. You can understand my dilemma as I am involved in the arts & although just a camera phone, most of these photos were historic & aesthetic or at least as to subject matter. Photo-ops don't reoccur. I have tried a couple of recovery apps from the market like Search Duplicates & Recover to no avail. I was only able to salvage stuff I'd sent out in messages. I've got several decades in computers & this is such a miserable beginner's piece of bad luck I can't believe it happened to me. They were precious photos! Yes, I turned on Titanium since & yes I even tried USB to laptop recoveries. Being on a MacBookPro I'm trying androidfiletransfer.dmg, but I'd have to upgrade to Peach Sunrise to get above Android 3.0 for that App to recognize the phone via USB & the programmer says installation zeros your data, so that pretty much toasts any secret hidden places where these photos may have been deposited. Don't want to do that & am still trying to find them. They certainly didn't make it to my external SD Card. If any of you techies out there know anything, please help & thanks. Despite decades of being in computing, unfamiliar & ever-changing hard or software can humble even the most seasoned veterans.

    Read the article

  • Forms authentication failed between web server and sql server

    - by Matt Bear
    I've actually found the solution, but I'm trying to understand why it failed, and why my solution fixed the problem. We have an application that uses forms authentication between a web server and sql server, web server runs server 2008, sql server runs 2008 r2, and sql server 2008. In august the sql server was patched with .net 3.5.1, the web server was untouched, and the forms authentication continued to work. 1 week ago we virtualized the web server onto our vSphere server because of failing hardware. Afterwards the form authentication failed with event code 4005, detail code 50201, The ticket supplied was invalid (on the sql server). In fact the sql server started generating Schannel errors and began blue screening 3-4 times a day. At this point I touched the sql server for the first time(ever), the errors were non specific, any reference to them I could find had to do with either zone alarm(which we don't run), or memory errors. So I applied service pack 1, which stopped the blue screening, but did not fix the forms authentication. At this point we had a work around, so we put it on the back burner while we completed another project, and I was able to get back on it last night. First thing was to adjust some code in the webconfig file on the sql server, nothing, next was regenerate and change out the machine key, still no change. Update the DNS servers, no change. Finally I went through and installed all windows updates, two reboots, (over RDP installed a network card driver which failed, and did not have my server room key, that was fun). After that, forms authentication was working again. And the sql server stopped generating as many errors, I've gotten two schannel errors since then. In short, forms authentication began failing when the web server was cloned onto a virtual machine, which caused the sql server to blue sceen? and forms authentication to fail. And could only be fixed by applying patches to the sql server?(I'm wishing I had patched the servers one at a time so I could know for sure which patch on which server fixed it). My question is why did it fail, and why did patching fix it? I hate fixing something without fully understanding the why and how.

    Read the article

  • Very poor read performance compared to write performance on md(raid1) / crypt(luks) / lvm

    - by Android5360
    I'm experiencing very poor read performance over raid1/crypt/lvm. In the same time, write speeds are about 2x+ faster on the same setup. On another raid1 setup on the same machine I get normal read speeds (maybe because I'm not using cryptsetup). OS related disks: sda + sdb. I have raid1 configuration with two disks, both are in place. I'm using LVM over the RAID. No encryption. Both disks are WD Green, 5400 rpm. IO test results on this raid1: dd if=/dev/zero of=/tmp/output.img3 bs=8k count=256k conv=fsync - 2147483648 bytes (2.1 GB) copied, 22.3392 s, 96.1 MB/s sync echo 3 > /proc/sys/vm/drop_caches dd if=/tmp/output.img3 of=/dev/null bs=8k - 2147483648 bytes (2.1 GB) copied, 15.9 s, 135 MB/s And here is the problematic setup (on the same machine). Currently I have only one sdc (WD Green, 5400rpm) configured in software raid1 + crypt (luks, serpent-xts-plain) + lvm. Tomorrow I will attach another disk (sdd) to complete this two-disk raid1 setup. IO tests results on this raid1: dd if=/dev/zero of=output.img3 bs=8k count=256k conv=fsync 2147483648 bytes (2.1 GB) copied, 17.7235 s, 121 MB/s sync echo 3 > /proc/sys/vm/drop_caches dd if=output.img3 of=/dev/null bs=8k 2147483648 bytes (2.1 GB) copied, 36.2454 s, 59.2 MB/s We can see that the read performance is very very bad (59MB/s compared to 135MB/s when using no encryption). Nothing is using the disks during benchmark. I can confirm this because I checked with iostat and dstat. Details on the hardware: disks: all are WD green, 5400rpm, 64mb cache. cpu: FX-8350 at stock speed ram: 4x4GB at 1066Mhz. Details on the software: OS: Debian Wheezy 7, amd64 mdadm: v3.2.5 - 18th May 2012 LVM version: 2.02.95(2) (2012-03-06) LVM Library version: 1.02.74 (2012-03-06) LVM Driver version: 4.22.0 cryptsetup: 1.4.3 Here is how I configured the slow raid1+crypt+lvm setup: parted /dev/sdc mklabel gpt type: ext4 start: 2048s end: -1 Now the raid, crypt and the lvm configuration: mdadm --create /dev/md1 --level=1 --raid-disks=2 missing /dev/sdc cryptsetup --cipher serpent-xts-plain luksFormat /dev/md1 cryptsetup luksOpen /dev/md1 md1_crypt vgcreate vg_sql /dev/mapper/md1_crypt lvcreate -l 100%VG vg_sql -n lv_sql mkfs.ext4 /dev/mapper/vg_sql-lv-sql mount /dev/mapper/vg_sql-lv_sql /sql So guys, can you help me identify the reason and fix it? It has to be something with the cryptsetup as there is no such read slowdown on the other setup (sda+sdb) where no encryption is present. But I have no idea what to do. Thanks!

    Read the article

  • Critique My Backup and Storage Plan

    - by MetaHyperBolic
    My current storage (RAID-1 off of a hardware RAID card) and backup (a spare drive) solutions for my home network are inadequate. I have too much data scattered on various one-off drives. It is time to evolve. Backups seem simple enough, at least: lots of big drives. However, I am bewildered by the number of choices for small home storage. The Drobo S looks appealing. So does the ReadyNAS. I am not looking for bunches of shiny features, I'm mostly interested in reliability. I am not interested in building Yet Another PC to create a file server or doing something in the cloud, or whatever. I'm stupid, so I am keeping it simple. Requirements for Main Volume: Starting working space roughly 2TB, with options for growth up to 5TB RAID or something RAID-like with at least one parity drive eSATA II for speed during backups Ability to shut down gracefully when alerted of low power by a UPS Optional but Desirable: Will take 2TB drives now with options for the larger 3TB drives coming in 2010-2011 Optional but Desirable: : RAID-6 or something similar, with two parity drives Optional but Desirable: : Hot spare Ethernet connection not required, as the volume will be shared via the same machines which runs my home print server Backups: Backup performed via ROBOCOPY in mirror mode to an external hard drive via a eSATA II connection. Start with rotating between two external 2TB hard drives, will go up to six external 2TB drives. Start with a weekly backup, move to a bi-weekly backup as more drives are added. Move to 3TB drives as the size of my main volume increases. Backup drives will be stored on an off-site location. Hard drives: I plan on buying all of the same model, but different batches from different vendors. I found a "burn-in" utility with which I can pound away on the drives for a couple of weeks before adding them to the backup pool or the main volume. I estimate that I am looking at roughly $1,500 to start, once I start throwing in two TB drives for backup and four for storage. So, are there any obvious flaws in my plan? What have I overlooked? Any suggestions for the storage device for my main volume that fits my requirements? Or do I just keep it simple, 2 drives in RAID-1, then perform due diligence with my backups, accepting that I will have to buy a whole new unit when my data grows past 2TB?

    Read the article

  • How do I troubleshoot root cause of a hung windows (2003) server?

    - by GregW
    I have a pair of Windows (2003 Server) servers both running MS SQL Server (2008 EE) that each hang every few months. This has been occurring intermittently :( for the past 15 months pretty much since we started using the servers. The symptoms are as-follows: I cannot remote desktop in to troubleshoot; when I attempt to, I get stuck on a blank black screen and am never offered a login prompt I can still ping the servers I can still open a SQL connection to the server, and, CURIOUSLY/BIZARRELY, when I do a "select getdate()", the time it returns appears to be stuck on the exact fraction of a second when (I presume) the server hung. Repeated attempts to do "select getdate()" keep getting that same date, suggesting that the clock is frozen. Filesharing attempts to connect to the hung server fail with the error message: "\ServerName is not accessible. You might not have permissions to use this network resource. Contact the administrator of this server to find out if you have access permissions. The server's clock is not synchronized with the primary domain controller's clock." This is consistent with a frozen clock. Post-reboot, if I investigate the Windows Event Viewer logs, I can see many security accesses (coming from me and others) that I recognize were login attempts during the "down" period, but all of them in the security log are associated with that same timestamp of when the server hung. This also suggests the clock is frozen. There is not a clear cause in the Application or System event logs. I have a local Admin account on the server and am in the process of getting a domain-credentialed Admin account for better remote admin access. HP is supposed to be supporting these machines and has some low-level ILO2 access but they seem incapable of finding the root cause. A reboot will "fix" the problem but I would like to get to the root cause and solve the issue. Has anyone ever seen something like this odd clock behavior?! (If it were just one server I'd perhaps say a bad hardware clock, but two?) Can anyone advise me on what I should try to troubleshoot this sort of situation to find the root cause (or what I should tell HP to try?)

    Read the article

  • Cannot exit X server, restart, shutdown or drop to tty when VGA monitor active

    - by terdon
    I have a strange problem. If I connect an external VGA monitor to my laptop, exiting the X environment in any way crashes the computer. For example, say I am working with my two monitors (the laptop's and one connected to my VGA port) active. Hitting Ctrl+Alt+F Key should take me down to a tty. What actually happens is that the VGA screen goes blank, as you would expect, but the laptop screen, although still on, shows nothing. I know the screen is on because it is slightly more illuminated than when it is off. When in this state, I can do nothing to regain access to the machine. I have tried: Ctrl+F Key (and even Ctrl+Alt+F Key, just in case) combinations and none seem to have any effect. Ctrl+Alt+Del : Nothing Magic SysRq key: Nothing Blindly typing my username and password and trying to reboot/shutdown or restart GDM or MDM: Nothing The only thing that works is a hard reset. The exact same behavior occurs when kiling the X server through Ctrl+Alt+Backspace, rebooting or shutdown. There is no difference if I reboot/shutdown/log out using the WM's graphical menu or if I use the shutdown or rebootcommands. It is also not WM-dependent. I have the same problem using Cinnamon, Gnome 3, MATE and xfce4. It is, however, VGA dependent. I have tried connecting another VGA monitor and have the same problem. I do not, however, have this problem if a screen is connected to the DisplayPort. It is, therefore, a VGA specific issue. To make things even stranger, this only occurs when both screens are active. If either the laptop screen or the VGA monitor is inactive the problem goes away. Finally, this problem arose when I installed the latest Linux Mint Debian (LMDE). It did not occur with the previous release of LMDE. I am not sure what has changed since I used the same kernel version in both releases (I had upgraded the kernel while on the previous release) and, I think, the same nvidia drivers. Oh, and yes, I have updated the nvidia driver. Hardware: Dell M4500 laptop CPU: Intel Core i7 RAM: 8GB Graphics: nVidia GT216 [Quadro FX 880M] Software: LMDE, kernel 3.2.0-2-amd64 Xorg: 1.11.4 nVidia kernel: 295.20-1+3.2.9-1 Possibly relevant files: /var/log/Xorg.0.log ~/.xsession-errors Does anyone have any ideas how to fix this? Thanks in advance for any help.

    Read the article

  • Linux RAID-0 performance doesn't scale up over 1 GB/s

    - by wazoox
    I have trouble getting the max throughput out of my setup. The hardware is as follow : dual Quad-Core AMD Opteron(tm) Processor 2376 16 GB DDR2 ECC RAM dual Adaptec 52245 RAID controllers 48 1 TB SATA drives set up as 2 RAID-6 arrays (256KB stripe) + spares. Software : Plain vanilla 2.6.32.25 kernel, compiled for AMD-64, optimized for NUMA; Debian Lenny userland. benchmarks run : disktest, bonnie++, dd, etc. All give the same results. No discrepancy here. io scheduler used : noop. Yeah, no trick here. Up until now I basically assumed that striping (RAID 0) several physical devices should augment performance roughly linearly. However this is not the case here : each RAID array achieves about 780 MB/s write, sustained, and 1 GB/s read, sustained. writing to both RAID arrays simultaneously with two different processes gives 750 + 750 MB/s, and reading from both gives 1 + 1 GB/s. however when I stripe both arrays together, using either mdadm or lvm, the performance is about 850 MB/s writing and 1.4 GB/s reading. at least 30% less than expected! running two parallel writer or reader processes against the striped arrays doesn't enhance the figures, in fact it degrades performance even further. So what's happening here? Basically I ruled out bus or memory contention, because when I run dd on both drives simultaneously, aggregate write speed actually reach 1.5 GB/s and reading speed tops 2 GB/s. So it's not the PCIe bus. I suppose it's not the RAM. It's not the filesystem, because I get exactly the same numbers benchmarking against the raw device or using XFS. And I also get exactly the same performance using either LVM striping and md striping. What's wrong? What's preventing a process from going up to the max possible throughput? Is Linux striping defective? What other tests could I run?

    Read the article

  • How can I repair my USB drive?

    - by yurko
    USB drive is in read only state and I can't repair it. First of all I tried erase it using dd: root@yurko-laptop:/home/yurko-laptop# ls -l /dev/disk/by-id | grep usb lrwxrwxrwx 1 root root 9 ??? 18 23:45 usb-Generic_Flash_Disk_C173828A-0:0 -> ../../sdb lrwxrwxrwx 1 root root 10 ??? 18 23:45 usb-Generic_Flash_Disk_C173828A-0:0-part1 -> ../../sdb1 root@yurko-laptop:/home/yurko-laptop# dd if=/dev/zero of=/dev/sdb dd: ?????? ? «/dev/sdb»: ?? ?????????? ????????? ????? 8257537+0 ??????? ??????? 8257536+0 ??????? ???????? ??????????? 4227858432 ????? (4,2 GB), 942,633 c, 4,5 MB/c After that I wanted to create new filesystem using fdisk: root@yurko-laptop:/home/yurko-laptop# fdisk /dev/sdb You will not be able to write the partition table. WARNING: DOS-compatible mode is deprecated. It's strongly recommended to switch off the mode (command 'c') and change display units to sectors (command 'u'). Command (m for help): p Disk /dev/sdb: 4227 MB, 4227858432 bytes 4 heads, 63 sectors/track, 32768 cylinders Units = cylinders of 252 * 512 = 129024 bytes Sector size (logical/physical): 512 bytes / 512 bytes I/O size (minimum/optimal): 512 bytes / 512 bytes Disk identifier: 0x00000000 Device Boot Start End Blocks Id System /dev/sdb1 18 32768 4126596 b W95 FAT32 Command (m for help): fdisk showed that the partition still exists and I can't write the partition table. I tried to delete the existing partition: Command (m for help): d Selected partition 1 Command (m for help): w Unable to write /dev/sdb root@yurko-laptop:/home/yurko-laptop# Why am I not be able to write the partition table? Does it mean that some hardware failure occurred? And is it possible to repair the current USB drive? I've tried to use hdparm and it showed that the readonly flag is on: root@yurko-laptop:/home/yurko-laptop# hdparm /dev/sdb /dev/sdb: SG_IO: bad/missing sense data, sb[]: f0 00 05 00 00 00 00 0a 00 00 00 00 26 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 multcount = 0 (off) readonly = 1 (on) readahead = 256 (on) geometry = 1016/131/62, sectors = 8257536, start = 0

    Read the article

  • compile lastest bnx2 driver on debian squeeze

    - by markus
    I want to upgrade the bnx2 network card driver in a Dell Power Edge R410. I downloaded the latest driver version from the broadcom website. If I want to compile the driver it fails with the following errors: make make -C bnx2/src KVER=2.6.32-5-amd64 PREFIX= make[1]: Entering directory `/tmp/netxtreme2-6.2.23/bnx2-2.0.23b/src' make -C /lib/modules/2.6.32-5-amd64/build SUBDIRS=/tmp/netxtreme2-6.2.23/bnx2-2.0.23b/src modules make[2]: Entering directory `/usr/src/linux-headers-2.6.32-5-amd64' Building modules, stage 2. MODPOST 2 modules make[2]: Leaving directory `/usr/src/linux-headers-2.6.32-5-amd64' make[1]: Leaving directory `/tmp/netxtreme2-6.2.23/bnx2-2.0.23b/src' make -C bnx2x/src KVER=2.6.32-5-amd64 PREFIX= make[1]: Entering directory `/tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src' make -C /lib/modules/2.6.32-5-amd64/build M=`pwd` modules make[2]: Entering directory `/usr/src/linux-headers-2.6.32-5-amd64' CC [M] /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_main.o In file included from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x.h:68, from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_main.c:80: /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_compat.h:1009:1: error: "PCI_VPD_LRDT_ID_STRING" redefined In file included from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_main.c:34: /usr/src/linux-headers-2.6.32-5-common/include/linux/pci.h:1327:1: error: this is the location of the previous definition In file included from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x.h:68, from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_main.c:80: /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_compat.h:1011:1: error: "PCI_VPD_LRDT_RO_DATA" redefined In file included from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_main.c:34: /usr/src/linux-headers-2.6.32-5-common/include/linux/pci.h:1328:1: error: this is the location of the previous definition In file included from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x.h:68, from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_main.c:80: /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_compat.h:1013:1: error: "PCI_VPD_LRDT_RW_DATA" redefined In file included from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_main.c:34: /usr/src/linux-headers-2.6.32-5-common/include/linux/pci.h:1329:1: error: this is the location of the previous definition In file included from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x.h:68, from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_main.c:80: /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_compat.h:1019:1: error: "PCI_VPD_SRDT_END" redefined In file included from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_main.c:34: /usr/src/linux-headers-2.6.32-5-common/include/linux/pci.h:1334:1: error: this is the location of the previous definition In file included from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x.h:68, from /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_main.c:80: /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_compat.h:1032: error: conflicting types for ‘pci_vpd_lrdt_size’ /usr/src/linux-headers-2.6.32-5-common/include/linux/pci.h:1355: error: previous definition of ‘pci_vpd_lrdt_size’ was here /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_compat.h:1037: error: conflicting types for ‘pci_vpd_srdt_size’ /usr/src/linux-headers-2.6.32-5-common/include/linux/pci.h:1366: error: previous definition of ‘pci_vpd_srdt_size’ was here /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_compat.h:1042: error: conflicting types for ‘pci_vpd_find_tag’ /usr/src/linux-headers-2.6.32-5-common/include/linux/pci.h:1391: error: previous declaration of ‘pci_vpd_find_tag’ was here /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_compat.h:1077: error: conflicting types for ‘pci_vpd_info_field_size’ /usr/src/linux-headers-2.6.32-5-common/include/linux/pci.h:1377: error: previous definition of ‘pci_vpd_info_field_size’ was here /tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_compat.h:1082: error: conflicting types for ‘pci_vpd_find_info_keyword’ /usr/src/linux-headers-2.6.32-5-common/include/linux/pci.h:1403: error: previous declaration of ‘pci_vpd_find_info_keyword’ was here make[5]: *** [/tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src/bnx2x_main.o] Fehler 1 make[4]: *** [_module_/tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src] Fehler 2 make[3]: *** [sub-make] Fehler 2 make[2]: *** [all] Fehler 2 make[2]: Leaving directory `/usr/src/linux-headers-2.6.32-5-amd64' make[1]: *** [bnx2x.o] Fehler 2 make[1]: Leaving directory `/tmp/netxtreme2-6.2.23/bnx2x-1.62.15/src' make: *** [l2build] Fehler 2

    Read the article

  • DVD Drive Failing on Windows 7

    - by Seth Spearman
    I have x64 Windows 7 running on an ASUS M50VM. The DVD drive works completely unreliably if not at all. But the story is not that simple so bear with me...here are the gory details. When I first got the machine it came with Windows XP and I upgraded it to Windows Vista X64 and the DVD worked fine. When Windows 7 RC2 came out I tried it on a Virtual Machine and I liked it so much that I upgraded the machine to Win7 RC1. The DVD worked fine. Of course, RC1 was going to start spontaneously rebooting, so when Windows 7 was released I DID A CLEAN INSTALL of Windows 7. Just to clarify...by clean install I mean I did a FORMAT of the HARD DRIVE and INSTALLED it from scratch. EVER since then the DVD mostly doesn't work. I can sometime read from disk but that will often hang. (Please see my description below of HANG for details.) CD or DVD writes ALWAYS fail with a HANG (I have done a successful write only one time.) Here is what I mean by HANG... *Explorer Window is unresponsive. *Any software accessing the DVD drive is unresponsive. *The DVD tray will not eject. *Using a paper clip will eject but the disk is usually spinning real hard. *Attempting to shut down windows will fail. I have waited as long as ten minutes but the whole OS seems to hang. I do a hard shutdown. *Sometimes accessing the DVD (when it does not cause a HANG) will still fail and the device will actually seem to disappear from the system until I reboot. A couple of other things. It is NOT a hardware failure. It is the Windows OS. I know this because I swapped out my DVD drive with a friend with the same model...his machine is fine (he is still running Vista X64) and my machine still fails. For what it is worth. I swapped out my primary disk with the INTEL 160GB SSD. EDIT Here is what System Information shows about my DVD drive Drive D: Description CD-ROM Drive Media Loaded No Media Type DVD Writer Name HL-DT-ST DVDRAM GSA-T50N ATA Device Manufacturer (Standard CD-ROM drives) Status OK Transfer Rate -1.00 kbytes/sec SCSI Target ID 0 PNP Device ID IDE\CDROMHL-DT-ST_DVDRAM_GSA-T50N________________RR04____\5&2B5B7F1D&0&1.0.0 Driver c:\windows\system32\drivers\cdrom.sys (6.1.7600.16385, 144.00 KB (147,456 bytes), 7/13/2009 7:19 PM) Any ideas? HELP! Seth B Spearman

    Read the article

  • Neighbour table overflow on Linux hosts related to bridging and ipv6

    - by tim
    Note: I already have a workaround for this problem (as described below) so this is only a "want-to-know" question. I have a productive setup with around 50 hosts including blades running xen 4 and equallogics providing iscsi. All xen dom0s are almost plain Debian 5. The setup includes several bridges on every dom0 to support xen bridged networking. In total there are between 5 and 12 bridges on each dom0 servicing one vlan each. None of the hosts has routing enabled. At one point in time we moved one of the machines to a new hardware including a raid controller and so we installed an upstream 3.0.22/x86_64 kernel with xen patches. All other machines run debian xen-dom0-kernel. Since then we noticed on all hosts in the setup the following errors every ~2 minutes: [55888.881994] __ratelimit: 908 callbacks suppressed [55888.882221] Neighbour table overflow. [55888.882476] Neighbour table overflow. [55888.882732] Neighbour table overflow. [55888.883050] Neighbour table overflow. [55888.883307] Neighbour table overflow. [55888.883562] Neighbour table overflow. [55888.883859] Neighbour table overflow. [55888.884118] Neighbour table overflow. [55888.884373] Neighbour table overflow. [55888.884666] Neighbour table overflow. The arp table (arp -n) never showed more than around 20 entries on every machine. We tried the obvious tweaks and raised the /proc/sys/net/ipv4/neigh/default/gc_thresh* values. FInally to 16384 entries but no effect. Not even the interval of ~2 minutes changed which lead me to the conclusion that this is totally unrelated. tcpdump showed no uncommon ipv4 traffic on any interface. The only interesting finding from tcpdump were ipv6 packets bursting in like: 14:33:13.137668 IP6 fe80::216:3eff:fe1d:9d01 > ff02::1:ff1d:9d01: HBH ICMP6, multicast listener reportmax resp delay: 0 addr: ff02::1:ff1d:9d01, length 24 14:33:13.138061 IP6 fe80::216:3eff:fe1d:a8c1 > ff02::1:ff1d:a8c1: HBH ICMP6, multicast listener reportmax resp delay: 0 addr: ff02::1:ff1d:a8c1, length 24 14:33:13.138619 IP6 fe80::216:3eff:fe1d:bf81 > ff02::1:ff1d:bf81: HBH ICMP6, multicast listener reportmax resp delay: 0 addr: ff02::1:ff1d:bf81, length 24 14:33:13.138974 IP6 fe80::216:3eff:fe1d:eb41 > ff02::1:ff1d:eb41: HBH ICMP6, multicast listener reportmax resp delay: 0 addr: ff02::1:ff1d:eb41, length 24 which placed the idea in my mind that the problem maybe related to ipv6, since we have no ipv6 services in this setup. The only other hint was the coincidence of the host upgrade with the beginning of the problems. I powered down the host in question and the errors were gone. Then I subsequently took down the bridges on the host and when i took down (ifconfig down) one particularly bridge: br-vlan2159 Link encap:Ethernet HWaddr 00:26:b9:fb:16:2c inet6 addr: fe80::226:b9ff:fefb:162c/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:120 errors:0 dropped:0 overruns:0 frame:0 TX packets:9 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:5286 (5.1 KiB) TX bytes:726 (726.0 B) eth0.2159 Link encap:Ethernet HWaddr 00:26:b9:fb:16:2c inet6 addr: fe80::226:b9ff:fefb:162c/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:1801 errors:0 dropped:0 overruns:0 frame:0 TX packets:20 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:126228 (123.2 KiB) TX bytes:1464 (1.4 KiB) bridge name bridge id STP enabled interfaces ... br-vlan2158 8000.0026b9fb162c no eth0.2158 br-vlan2159 8000.0026b9fb162c no eth0.2159 The errors went away again. As you can see the bridge holds no ipv4 address and it's only member is eth0.2159 so no traffic should cross it. Bridge and interface .2159 / .2157 / .2158 which are in all aspects identical apart from the vlan they are connected to had no effect when taken down. Now I disabled ipv6 on the entire host via sysctl net.ipv6.conf.all.disable_ipv6 and rebooted. After this even with bridge br-vlan2159 enabled no errors occur. Any ideas are welcome.

    Read the article

  • Add Mirror for volumes other than the last one in Windows 7 (disk "not up-to-date")

    - by rakslice
    I'm using Windows 7 x64 Ultimate. I have an existing 4TB disk with 3 NTFS volumes, a new 3TB blank disk, and I'm trying to mirror the volumes onto the new disk. My Windows install is on an SSD which is Disk 0. The 4TB disk with volumes is Disk 1, and the new blank disk is Disk 2. I can add a mirror successfully for the last volume, but when I try to add a mirror for the first volume I immediately get errors (see below). Is there something I special I need to do to add a mirror for a volume other than the last one? More info: I opened Disk Management, right-clicked on the first volume on the existing disk, went to Add Mirror, and selected the new disk. The first time I did this I was prompted to convert the new disk to a Dynamic Disk, which I approved. Subsequently I got a message: The operation failed to complete because the Disk Management console view is not up-to-date. Refresh the view by using the refresh task. If the problem persists close the Disk Management console, then restart Disk Management or restart the computer. I've refreshed disk management, restarted the computer, and converted the new disk to basic and back to dynamic, but I still get that error message. Looking around for suggestions of a workaround, I saw a suggestion to use the diskpart command line tool. Running diskpart from the Start Menu as Administrator, I did select volume 2 (the first volume I want to mirror) and then add disk 2 (the new disk), and received a somewhat similar error: Virtual Disk Service error: The disk's extent information is corrupted. DiskPart has referenced an object which is not up-to-date. Refresh the object by using the RESCAN command. If the problem persists exit DiskPart, then restart DiskPart or restart the computer. A rescan appears to be successful: DISKPART> select disk 2 Disk 2 is now the selected disk. DISKPART> rescan Please wait while DiskPart scans your configuration... DiskPart has finished scanning your configuration. but attempting to add the mirror again resulted in the same error. The only similar report I found online was this: http://www.sevenforums.com/hardware-devices/335780-unable-mirror-all-but-last-partition-drive.html Based on that I attempted to mirror the last volume on the disk to the new disk using diskpart, and that started successfully -- it is currently resynchronizing. More Background: In the course of dealing with a failing 3TB hard drive, I bought a replacement 4TB drive and installed it, then copied the partitions from the failing drive to it using Minitool Partition Wizard Home, and then removed the failing drive and was up and running again normally. Now I've received a warranty replacement for the failing drive, and installed it, and now I'm attempting to mirror my partitions to it.

    Read the article

  • Flickering issue in external monitor when used with Acer Aspire One D260 netbook (Intel GMA 3150)

    - by seyenne
    I recently purchased a Acer netbook, Aspire One D260. It runs flawlessly. Yesterday I bought a Samsung 23" TFT with a native resolution of 1920x1080. According to the information found in the internet and my local computer dealer, the Intel chipset can handle the native resolution of the monitor. However, this is only partly the case. I use the VGA cable to connect, the monitor instantly switches to the native resolution and now the problem: Occasionally, especially the first 2 hours after booting up, I have a flickering all over the screen, sometimes the entire screen is shaking and spinning around like crazy. I figured out that lowering the resolution avoids the flicker but this helps only for some time. I can rule out that it's the monitor's problem since I found no issues with another notebook. Right now, I have no problems with the netbook, for about 30 minutes I didn't experience any issues... But I don't know for how long, it occurs without warning :-) I'm worried that if I would bring the netbook back to the dealer and explain my problem, after testing it on an external screen in the local shop, everything works just fine... And I won't get helped with the problem because I can't prove it. (I'm currently in Thailand and over here, customer service is nothing like back home in Germany) What can I do? Is this a driver related issue? (I installed the latest GPU driver) Is it because of the VGA cable? (But why does it work sometimes without any problems and with no issues on the other notebook) I monitored the GPU/CPU temperature, nothing changes really over time.. Can it simply be a faulty GPU and is a replacement justifiable? I'm really stressed now because for the time I'm writing, the flickering didn't occur... but for sure, soon or later it will happen again.. I forgot to mention, the problem also happens if the netbook runs on battery, unplugged. So the only hardware that is plugged is the TFT screen. ...........and here it comes again, flickering has just begun. NEED HELP! Thank you all for reading through this and giving any suggestions if possible. Cheers

    Read the article

  • Sysadmin 101: How can I figure out why my server crashes and monitor performance?

    - by bflora
    I have a Drupal-powered site that seems to have neverending performance problems. It was butt-slow about 5 months ago. I brought in some guys who installed nginx for anonymous visitors, ajaxified a few queries so they wouldn't fire during page load, and helped me find a few bottlenecks in the code. For about a month, the site was significantly faster, though not "fast" by any stretch of the word. Meanwhile, I'm now shelling out $400/month to Slicehost to host a site that gets less than 5,000/uniques a day. Yes, you read that right. Go Drupal. Recently the site started crashing again and is slow again. I can't afford to hire people to come in, study my code from top to bottom, and make changes that may or may not help anymore. And I can't afford to throw more hardware at the problem. So I need to figure out what the problem is myself. Questions: When apache crashes, is it possible to find out what caused it to crash? There has to be a way, right? If so, how can I do this? Is there software I can use that will tell me which process caused my server to die? (e.g. "Apache crashed because someone visited page X." or "Apache crashed because you were importing too many RSS items from feed X.") There's got to be a way to learn this, right? What's a good, noob-friendly way to monitor my current apache performance? My developer friends tell me to "just use Top, dude," but Top shows me a bunch of numbers without any context. I have no clue what qualifies as a bad number or a good number in Top, or which processes are relevant and which aren't. Are there any noob-friendly server monitoring tools out there? Ideally, I could have a page that would give me a color-coded indicator about how apache is performing and then show me a list of processes or pages that are sucking right now. This way, I could know when performance is bad and then what's causing it to be so bad. Why does PHP memory matter? My apparently has a 30MB memory foot print. Will it run faster if I bring that number down? Thanks for any advice. I spent a year or so trying to boost my advertising income so I could hire a contractor to solve my performance woes. I didn't want to have to learn all this sysadmin voodoo. I'm now resigned to the fact that might not have a choice.

    Read the article

  • Device Manager - does USB listing look right?

    - by Carl
    I obtained the drivers from the manufacturer for my HT-Link NEC USB 2.0 2-port Cardbus card. When I plugged in the card before I got the drivers, 3 new entries showed up in the Device Manager - two "NEC PCI to USB Open Host Controller" and one "Standard Enhanced PCI to USB Host controller." With the card plugged in, I uninstalled those two drivers. I then removed the card. I copied the new drivers to c:\windows\system32\drivers and the .inf file to c:\windows\inf. I also copied the drivers & inf to a new directory called c:\windows\drivers\ousb2. I reinserted the card. Windows automatically installed the same drivers as before. I selected 'update driver' on the "NEC PCI to USB..." entry and didn't see any other options. I then selected 'have disk' and pointed to c:\windows\drivers\ousb2 and got a message "The specified location does not contain information about your hardware." I then selected 'update driver' on the "Standard Enhanced PCI to USB...," and manually selected "USB 2.0 Enhanced Host Controller" (OWC 4/15/2003 2.1.3.1). Windows then automatically found a USB root hub, and I manually selected "USB 2.0 Root Hub Device" (OWC 4/15/2003 2.1.3.1). Now there are two sections in the Device Manager titled "Universal Serial Bus controllers." I plugged in my external USB hard disk adapter, and "USB Mass Storage Device" was added to the first set. Here's how it looks (w/drivers from the properties): [Universal Serial Bus controllers] Intel(R) 82801DB/DBM USB 2.0 Enhanced Host Controller - 24CD (6/1/2002 5.1.2600.0) Intel(R) 82801DB/DBM USB Universal Host Controller - 24C2 (7/1/2001 5.1.2600.5512) Intel(R) 82801DB/DBM USB Universal Host Controller - 24C4 (7/1/2001 5.1.2600.5512) Intel(R) 82801DB/DBM USB Universal Host Controller - 24C7 (7/1/2001 5.1.2600.5512) NEC PCI to USB Open Host Controller (7/1/2001 5.1.2600.5512) NEC PCI to USB Open Host Controller (7/1/2001 5.1.2600.5512) USB Mass Storage Device USB Root Hub (7/1/2001 5.1.2600.5512) (5 more USB Root Hubs - same driver) [Universal Serial Bus controllers] USB 2.0 Enhanced Host Controller (OWC 4/15/2003 2.1.3.1) USB 2.0 Root Hub Device (OWC 4/15/2003 2.1.3.1) When I unplug the card the two "NEC PCI to USB..." entries in the first set disappear, and the whole second set disappears. (I unplugged the hard disk adapter first...) The hard disk adapter still doesn't work in that Cardbus card with the new drivers. I don't think the above looks right - a second set of USB controllers listed in the Device Manager, and the NEC entries still in the first set, and the the USB mass storage device still in the first set. Any help appreciated. (Windows XP PRO SP3 w/all current updates.)

    Read the article

  • Optimal setup for ASUS P6X58D Premium BIOS (no OC)?

    - by rumtscho
    Normally, I'd trust the mainboard manufacturer to choose the best options as defaults. But I had trouble with the board, because even with Quick Boot enabled, it booted twice as slowly as a Pentium 4 Celeron. Then I changed lots of options at once (most of them weren't explained in the manual, just mentioned with a single sentence) and the boot time is only marginally worse than the Pentium 4 (54 sec against 46 sec from button to pw entering screen). Now I don't know if I have turned something off which should have stayed on. I guess I even won't be able to boot from a CD now, because even though it is present in the boot sequence, I took off a timeout I think it needs to check whether there is a disk in the drive. The second reason is that I don't have an internal HDD, only a SSD. I forgot my sources blush but I am under the impression that today's BIOS and OS options are geared toward booting from a HDD, which is often less than optimal when one boots from a SSD, especially when there are functions which cause avoidable writing cycles, as a SSD wears out after too many writing cycles. Most of the things I've read concern the OS, but there are some BIOS-relevant options too. I am especially confused about the disk mode. The board supports AHCI, IDE-simulation and RAID, but of the different articles I've read, there is a proponent for each and no clear arguments for any. So can one tell me which options are important in general and which are important for a SSD-only system? I don't want to overclock the CPU, so you don't have to say anything about this (yes I know the board is meant for OC:)). I am thinking of overclocking the RAM, since they sold me 1600er heatsinked modules which are running at 1066 now, but I'm not sure yet about that. The rest of the system: i7-930, Intel X25-m G2, 6 GB RAM, GTS 250, some no-name Blue-ray ROM. 2 external HDDs over USB 2.0. Lots of other USB-connected hardware (12 devices I think), no SATA 3 drives (will disabling the controller have an impact on performance?), no LAN, only WiFi. Lucid Lynx 64 bit, no dual boot, no virtual installations. The main uses of the system are: managing and playing/showing all the media stored on the external disks, lots of image manipulation, some video editing, a bit of (non-demanding) gaming, rarely development. Lots of Internet surfing too, but this shouldn't have much impact on performance.

    Read the article

  • Aliased network interfaces and isc dhcp server

    - by Jonatan
    I have been banging my head on this for a long time now. There are many discussions on the net about this and similar problems, but none of the solutions seems to work for me. I have a Debian server with two ethernet network interfaces. One of them is connected to internet, while the other is connected to my LAN. The LAN network is 10.11.100.0 (netmask 255.255.255.0). We have some custom hardware that use network 10.4.1.0 (netmask 255.255.255.0) and we can't change that. But we need all hosts on 10.11.100.0 to be able to connect to devices on 10.4.1.0. So I added an alias for the LAN network interface so that the Debian server acts as a gateway between 10.11.100.0 and 10.4.1.0. But then the dhcp server stopped working. The log says: No subnet declaration for eth1:0 (no IPv4 addresses). ** Ignoring requests on eth1:0. If this is not what you want, please write a subnet declaration in your dhcpd.conf file for the network segment to which interface eth1:1 is attached. ** No subnet declaration for eth1:1 (no IPv4 addresses). ** Ignoring requests on eth1:1. If this is not what you want, please write a subnet declaration in your dhcpd.conf file for the network segment to which interface eth1:1 is attached. ** I had another server before, also running Debian but with the older dhcp3 server, and it worked without any problems. I've tried everything I can think of in dhcpd.conf etc, and I've also compared with the working configuration in the old server. The dhcp server need only handle devices on 10.11.100.0. Any hints? Here's all relevant config files: /etc/default/isc-dhcp-server INTERFACES="eth1" /etc/network/interfaces (I've left out eth0, that connects to the Internet, since there is no problem with that.) auto eth1:0 iface eth1:0 inet static address 10.11.100.202 netmask 255.255.255.0 auto eth1:1 iface eth1:1 inet static address 10.4.1.248 netmask 255.255.255.0 /etc/dhcp/dhcpd.conf ddns-update-style none; option domain-name "???.com"; option domain-name-servers ?.?.?.?; default-lease-time 86400; max-lease-time 604800; authorative; subnet 10.11.100.0 netmask 255.255.255.0 { option subnet-mask 255.255.255.0; pool { range 10.11.100.50 10.11.100.99; } option routers 10.11.100.102; } I have tried to add shared-network etc, but didn't manage to get that to work. I get the same error message no matter what...

    Read the article

< Previous Page | 462 463 464 465 466 467 468 469 470 471 472 473  | Next Page >