Search Results

Search found 30398 results on 1216 pages for 'embedded sql'.

Page 480/1216 | < Previous Page | 476 477 478 479 480 481 482 483 484 485 486 487  | Next Page >

  • Microsoft Releases Windows Server 2012

    Windows Server 2012 offers expanded virtualization capabilities and works with Windows Azure, the software company's cloud platform. It can deliver more than 200 public, private and hybrid cloud services. The goal seems to be to deliver any application on any cloud. Rand Morimoto, president of Microsoft partner Convergent Computing, sees a number of major selling points for Windows Server 2012. For instance, its deduplication features can save a company 40 to 50 percent in storage space. Its automated IT management capabilities enable it to manage a large number of virtual machines. It can eve...

    Read the article

  • comparing two tables [closed]

    - by sza
    I have two identical table ie all the columns are identical and one of the datatype is Text, one is varchar(255) and the rest are int. Lets say the table name is 'AAAAA'. Table AAAAA was processed and backed up earlier this month. Both the tables were storing data and now the second table is only storing data. I need to find unmatching records from the second table (BBBBB) which is storing data right now and add those records to Table AAAAA. Your help will be highly appreciated. I tried to use 'EXCEPT' but it does not support text datatype.

    Read the article

  • Reliable Storage Systems for SQL Server

    By validating the IO path before commissioning the production database system, and performing ongoing validation through page checksums and DBCC checks, you can hopefully avoid data corruption altogether, or at least nip it in the bud. If corruption occurs, then you have to take the right decisions fast to deal with it. Rod Colledge explains how a pessimistic mindset can be an advantage...Did you know that DotNetSlackers also publishes .net articles written by top known .net Authors? We already have over 80 articles in several categories including Silverlight. Take a look: here.

    Read the article

  • Programming Data: .NET, SQL Server and You

    Welcome to the home page for my new book. Come back soon for a sample chapter....Did you know that DotNetSlackers also publishes .net articles written by top known .net Authors? We already have over 80 articles in several categories including Silverlight. Take a look: here.

    Read the article

  • Does programmable hardware exist to allow hardware to be programmed by computers?

    - by agentbanks217
    I am a programmer and I have never really dealt with the hardware of anything, only software. I want to start building things that I can control from my computer using programming. My question is are there such devices on the market that have a programmable interface or API? For example, I want to build an automated window blinds opening/closing device, and I would like to be able to control it from my computer e.g. writing an app or some code to schedule them when to open and close. I would like to know if there are any devices that can be programmed to do that (the computer part)?

    Read the article

  • Windows Azure Active Directory: Should You Use It?

    Computerworld offers a full review of the developer preview version of WAAD. Jonathan Hassell, the review's author, effectively gave the service a grade of incomplete. While you can't expect something that's effectively a beta to include everything that will be in the final version, WAAD presented a number of annoying problems that definitely need fixing before it can attract a wide share of the market. First, you can't even try out the service unless you sign up for a trial of Office 365, Microsoft's cloud Office suite. The software giant does plan to let you bring up an instance of WAAD as...

    Read the article

  • Best way to rename existing unique field names in database?

    - by Rajdeep Siddhapura
    I have a database table that contains id, filename, userId id is unique identifier filename should also be unique table may contain 10000 records When a user uploads a file it should be entered in database with given rules: If there is no record with same filename, it should be added as it is (Ex. foobar.pdf) If there is record with same filename, it should be added as uploadedName(2).ext (foobar(2).pdf) If there are n records with same base filename (foobar), it should be added as uploadedName(n+1).ext (foobar(20).pdf) Now if foobar(2).pdf is uploaded, it should be added as foobar(2)(2).pdf & so on This pattern needs to be followed because the file is already being uploaded at client side using ajax before sending the details to server and the file hosting service follows the above rules to name the files. My solution: maintain a file that contains all the names and the number of times it has occurred. if a filename that exists in file is entered, increase occurrence count and new name is generated, else add to it to file if the new name generated is in database, add it to file and generate new name

    Read the article

  • how to access mysql table from wamp database using this php code? [migrated]

    - by user3909877
    how to access tables from database by using php in wamp server.i have done the following code but its not working for some reason.is there anything to put in 'action=""'.it is not giving any error but displaying the same page.i want to display table from database on any different entry in dropdown menu and pressing search button.. <p class="h2">Quick Search</p> <div class="sb2_opts"> <p> </p> <form method="post" action="" > <p>Enter your source and destination.</p> <p> From:</p> <select name="from"> <option value="Islamabad">Islamabad</option> <option value="Lahore">Lahore</option> <option value="murree">Murree</option> <option value="Muzaffarabad">Muzaffarabad</option> </select> <p> To:</p> <select name="To"> <option value="Islamabad">Islamabad</option> <option value="Lahore">Lahore</option> <option value="murree">Murree</option> <option value="Muzaffarabad">Muzaffarabad</option> </select> <input type="submit" value="search" /> </form> </form> </table> <?php if(isset($_POST['from']) and isset($_POST['To'])) { $from = $_POST['from'] ; $to = $_POST['To'] ; $table = array($from, $to); $con=mysqli_connect("localhost"); $mydb=mysql_select_db("homedb"); if (mysqli_connect_errno()) { echo "Failed to connect to MySQL: " . mysqli_connect_error(); } switch ($table) { case array ("Islamabad", "Lahore") : $result = mysqli_query($con,"SELECT * FROM flights"); echo "</flights>"; //table name is flights break; case array ("Islamabad", "Murree") : $result = mysqli_query($con,"SELECT * FROM `isb to murree`"); echo "</`isb to murree`>"; //table name isb to murree ; break; case array ("Islamabad", "Muzaffarabad") : $result = mysqli_query($con,"SELECT * FROM `isb to muzz`"); echo "</`isb to muzz`>"; break; //..... //...... default: echo "Your choice is nor valid !!"; } } mysqli_close($con); ?>

    Read the article

  • Problem inserting in two different tables [closed]

    - by imvarunkmr
    I have written an insert statement which inserts a record into Table1. Table1 has a column "ID" which is an auto_increment(Identity) primary key. How can I fetch the newly generated "ID" and as I need to Insert this value as foreign key in Table2? Note : I have written INSERT statement in a stored procedure and I am calling this procedure using C# Alternative suggestions to link both tables are also welcomed :)

    Read the article

  • Question on PL/SQL - Evaluate the PL/SQL block given above and determine the data type and value of each of the following variables [closed]

    - by Annie
    DECLARE v_custid NUMBER(4) := 1600; v_custname VARCHAR2(300) := 'Women Sports Club'; v_ new_custid NUMBER(3) := 500; BEGIN DECLARE v_custid NUMBER(4) := 0; v_custname VARCHAR2(300) := 'Shape up Sports Club'; v_new_custid NUMBER(3) := 300; v_new_custname VARCHAR2(300) := 'Jansports Club'; BEGIN v_custid := v_new_custid; v_custname := v_custname || ' ' || v_new_custname; END; v_custid := (v_custid *12) / 10; END; /

    Read the article

  • ????????2012?11??: ?SQLTXPLAIN???????SQL??(???)

    - by lanwang
    ????11?????????????(???)???????????OSWatcher Black Box????????;??OSWbb?????????????????;???????OSWatcher Black Box;???????????OSWatcher Black Box Analyzer (OSWbba)?????OSWbb??????  OSWatcher Black Box????????????????????????????,?????:”??OSW (OSWatcher Black Box) ????“??2012?6????????“?RAC????????????” WebEx??????(???)?????:2012?11?15?15:00(????)  ????: 250 409 927 ????????  1. ??????:https://oracleaw.webex.com/oracleaw/onstage/g.php?d=250409927&t=a2. ?????????????????,???????????,????????? InterCall????????Webex???????,???????????,??????:    - ????ID: 31151003   - ????????: 1080 044 111 82   - ?????????: 1080 074 413 29   - ????: 8009 661 55   - ????: 00801148720   - ????????????????MOS?? 1148600.1 ???????:????????????,??????????(31151003)??????(First Name and Last Name)

    Read the article

  • windows authentication vs sql server authentication for asp.net forms authentication site

    - by Brij
    I have a database and a site having forms authentication. It is working fine with VS2008. This time, I am using "Trusted_connection =True". But when it is opened from outside or directly from browser then I am getting error "Login failed for user 'NT AUTHORITY\ANONYMOUS LOGON'." I know this is due to permission. SQL server is based on windows authentication. What is the best approach to manage user to connect sql server? Should I enable sql server authentication? Let me know what to do so that it makes the production feel and there wouldn't be any problem during deployment. Note: Sql server is installed on domain server.

    Read the article

  • micro-SD card initialization using SPI interface

    - by Ron
    I'm using a micro-SD card in an embedded design. The card is connected to a microcontroller using the SPI interface. It worked fine for all cards I've used before, but now my new card will not initialize. The card is a Transcend 2GB micro-SD card (TS2GUSD). After sending the initial clock train to switch to SPI mode I do the following: 1) CMD0 (Argument 0, CRC 0x95) - Response 0x01 - OK 2) CMD8 (Argument 0x000001AA, CRC 0x87) - Response 0x01 0x000001AA - Means it's SDC V2+ card, the Voltage range 2.7V~3.6V is supported - OK Then I should send the ACMD41 command, but when sending the CMD55 (argument 0, CRC 0) that must precede CMD41, I get response 0x05 - Illegal Command. I've also tried to send CMD1 (for MMC cards), but it gives a similar Illegal Command response. The code works fine with my Sandisk 2GB micro-SD card. Does anyone have any idea? Thanks, -Ron-

    Read the article

  • Which ORM to use with SQL Azure?

    - by Jamie Chapman
    Just wondering what everyones thoughts on what ORM to use for SQL Azure? I'm fairly comfortable using LINQ-to-SQL and I believe it is possible to get it working with SQL Azure. However, from my understanding (correct me if I'm wrong), no further improvements will be made to Linq-to-SQL in future releases of the .NET framework? Alternatively, there is the entity framework... and further afield from the Microsoft Camp is NHibernate. Ideally, any additional suggestions made should be free or open source. I have seen Telerik's ORM but this of course, is a commercial product. I can get the definitions/benefits of each ORM myself by doing a Google search, but I was just interested in peoples opinions as to which ORM seems to work best for them (even if it is none of the above).

    Read the article

  • SQLCLR and DateTime2

    - by Moe Sisko
    Using SQL Server 2008, Visual Studio 2005, .net 2.0 with SP2 (has support for new SQL Server 2008 data types). I'm trying to write an SQLCLR function that takes a DateTime2 as input and returns another DateTime2. e.g. : using System; using System.Data.SqlTypes; using Microsoft.SqlServer.Server; namespace MyCompany.SQLCLR { public class DateTimeHelpCLR { [SqlFunction(DataAccess = DataAccessKind.None)] public static SqlDateTime UTCToLocalDT(SqlDateTime val) { if (val.IsNull) return SqlDateTime.Null; TimeZone tz = System.TimeZone.CurrentTimeZone; DateTime res = tz.ToLocalTime(val.Value); return new SqlDateTime(res); } } } Now, the above compiles fine. I want these SqlDateTimes to map to SQL Server's DateTime2, so I try to run this T-SQL : CREATE function hubg.f_UTCToLocalDT ( @dt DATETIME2 ) returns DATETIME2 AS EXTERNAL NAME [SQLCLR].[MyCompany.SQLCLR.DateTimeHelpCLR].UTCToLocalDT GO This gives the following error : Msg 6551, Level 16, State 2, Procedure f_UTCToLocalDT, Line 1 CREATE FUNCTION for "f_UTCToLocalDT" failed because T-SQL and CLR types for return value do not match. Using DATETIME (instead of DATETIME2) works fine. But I'd rather use DATETIME2 to support the increased precision. What am I doing something wrong, or is DateTime2 not (fully) supported by SQLCLR ?

    Read the article

  • How to know the exact statement fired in Data app block?

    - by AJ
    Hi We are using "Enterprise Library Data Access Application Block" to access SQL Server database. In DataAccess layer, we are calling application block's API. Internally it must be resolving the command and parameters into SQL statement. How can I know what SQL query goes to database? Thanks AJ

    Read the article

  • UART speed possibly wrong

    - by Mike
    My brain is fried, so I thought I would pass this one to the community. When sending 1 character to my embedded system, it consistently thinks it receives 2 characters. The first received character seems to map to the transmitted character (in some unkown way) and the second received character is always 0xff Here is what I observed: Tx char (in hex) Rx character (in hex), I left out the second byte (always ff) 31 9D 32 9B 33 99 61 3D 62 3B 63 39 64 37 65 35 41 7D 42 7B 43 79 I have check my clocks and them seem to be ok. The only diff between this non working version and the previous version is that i am now using a RS485 chip. I have traced the signal all the way up to the MCU and it looks fine (confirmed the bit value on the rx pin)

    Read the article

  • sql database connection on remote server

    - by arti pathak
    i create my web site on asp.net and i create database in sql using inbuilt it in visual studio i use step to create database 1.right click on solution explorer then add newSqldatabase then ok then if i connect it by coding then it will work on my local PC but actuall i am making website so i want to store it on my web server then if i load databse file (.mdf) file in my web server where my all files are loaded then it is showing it error "A network-related or instance-specific error occurred while establishing a connection to SQL Server. The server was not found or was not accessible. Verify that the instance name is correct and that SQL Server is configured to allow remote connections. (provider: SQL Network Interfaces, error: 26 - Error Locating Server/Instance Specified)" so please help me and send me all step how i create database and what coding i use to connect on remote server....... Thank You......

    Read the article

  • Oracle 10g express home page is not coming up

    - by Adnan Anwar
    Hello All: My Oracle 10g Express Edition , I can login in the SQL plus but I cannot login into oracle via SQL developer and cannot view the Home page at link http://127.0.0.1:8080/apex. This was working fine until yesterday. I have checked via (WINDOWS)netstat -ab and no other app is using the 8080 port. The only thing I did today was I changed my SQL server 2005 Developer edition from Windows authentication to Mixed Mode authentication. Can anyone let me know how to get the Oracle Web page and the SQL Developer to work. I will gratly appreciate that. Thanks! Adnan A.

    Read the article

  • OMAP 3530: How fast can I toggle an IO?

    - by raj.tiwari
    I am putting together an application for OMAP 3530 SoC. This application will run some user interface code on embedded linux and invoke waveform generation code on the DSP. The DSP and Linux sides will interact over DSP/BIOS link. My questions are: What is the highest frequency at which my DSP-side code can toggle a GPIO line? If I want to toggle multiple GPIO lines at this hight rate, how fast can I go? Thanks for any insights. -Raj

    Read the article

  • Monitoring pthread context switching

    - by simon
    I would like to monitor the the context switching behavior in a multi-threaded pthread application. In other RTOSes(Micro C OS) I have been able to register a context switch callback for each thread in the application, and then log (or toggle a gpio) and watch the thread context switching in real time. This was a valuable tool for debugging the real time behavior and interaction of the multiple threads. My current environment is embedded linux utilizing the pthread api. Is there a way to montior each of the context switches?

    Read the article

  • Free static checker for C99 code

    - by detly
    I am looking for a free static checker for C99 code (including GCC extensions) with the ability to explicitly say "these preprocessor macros are always defined." I need that last part because I am compiling embedded code for a single target processor. The compiler (Microchip's C32, GCC based) sets a macro based on the selected processor, which is then used in the PIC32 header files to select a processor-specific header file to include. cppcheck therefore fails because it detects the 30 different #ifdefs used to select one of the many possible PIC32 processors, tries to analyse all possible combinations of these plus all other #defines, and fails. For example, if splint could process C99 code, I would use splint -D__PIC32_FEATURE_SET__=460 -D__32MX460F512L__ \ -D__LANGUAGE_C__ -I/path/to/my/includes source.c

    Read the article

< Previous Page | 476 477 478 479 480 481 482 483 484 485 486 487  | Next Page >