Search Results

Search found 26810 results on 1073 pages for 'fixed point'.

Page 484/1073 | < Previous Page | 480 481 482 483 484 485 486 487 488 489 490 491  | Next Page >

  • MacBook Pro (OSX Lion) - shutdown automatically before reaching login screen

    - by mkk
    When I try to lunch my MacBook Pro I can see a progress bar on loading screen. It goes to 1/15 or something like this and then it shut downs - I cannot reach even login screen. It happened to me 2 months ago, I have 'fixed' this by formatting my hard drive and installing OSX (Lion) again. This time I think that situation is a little bit different - I am able to enter single-user mode by pressing cmd + s. I then type /sbin/fsck -yf, I get the error: ** Checking Journaled HFS Plus volume. The volume name is Macintosh HD ** Checking extents overflow file. ** Checking catalog file. Invalid node structure (4, 24704) ** The volume Macintosh HD could not be verified completely. /dev/rdisk0s2 (hfs) EXITED WITH SIGNAL 8 but when I type exit, I can the login screen and I can log in. I tried a lot of things, booting from recovery partition and choosing disk utility to repair the disc, but I get error that it cannot be repaired. I have googled for hours and the only real solution I have found was to buy Disc warrior that might fix the issue. Any other suggestions? Secondary question is what causes this issue? I thought the reason are bad sectors, but Smart Utility haven't found any. I found suggestion that RAM could cause this kind of issue as well, so I downloaded rember and made memory test - all tests passed. Right now I have used my solution of entering single-mode user and then typing exit, however I am not sure how long it will 'work'. Of course I have back-uped what I considered important. Thanks for the help in advance! UPDATE: I guess Smart Utility was not very useful, I mnaged to get input/output error, which I believe is equivalent to bad sector.

    Read the article

  • Strange IIS hits originating from Trend Micro

    - by TesterTurnedDeveloper
    I'm trying to trace thru an error on a extranet site I maintain. I've had a look thru the logs, and I'm seeing hits originate from these IP addresses: 216.104.15.130 216.104.15.138 216.104.15.142 216.104.15.13 150.70.84.49 150.70.84.44 Network-tools.com gives 'TREND MICRO INCORPORATED' as the owner of all these IPs. The hits fail as they aren't sending any cookies (therefore aren't considered logged in). The hits are to pages containing URLs that only the logged in user would see, i.e. ImageEdit.aspx?ImageId=467424. I.e. the server isn't guessing these URLs, someone would have to log into the site to know these URLs exist. Theory: the Trend Antivirus client grabs URLs and sends them to the server for 'extra processing'? Googling around gives me this: http://www.forumpostersunion.com/showthread.php?p=51272 - where people are reporting comment spam from these addresses. The articles says their servers have been hacked (a few months ago, presumably fixed now?). A hacked server wouldn't explain how the URLs have been plucked off the user's PCs. Has anyone seen this before? Anything nefarious going on here?

    Read the article

  • moving raid 10 to another identical server both on Smart Array 6i controllers

    - by SalimQrdl
    I have dead HP DL 380G4 with RAID 1+0 with 1 logical volume from 4x72GB drives on built-in Smart Array 6i 128Mb BBWC. It was shut down properly. It seems it was usual death for Proliant with ILO led 2,3,8 lighting. I want to move array to another identical server with same raid firmware level. What is the best strategy?: I have RAID 1+0 on bay 0 bay 1 bay 2 bay 3 As I understand bay0+bay1 are in RAID 1 , bay2+bay3 are in RAID 1, and both RAID 1 pairs are in RAID 0. So should I : Clear RAID config on new server, insert bay 0, bay 2 and power-on or Create RAID 1+0 with 1 logical volume from clear HDDs , and then poweroff ,remove HDDs and insert 2 HDDs(bay 0, bay 2) from old RAID 1+0. then power-on. (each hdd has its raid position info stored but may be could work on same config) According to documentation for Smart Array 6i it could be possible to migrate. however one requirement point is unclear for me Before you move drives, the following conditions must be met: • The array is in its original configuration. " What is orginal and non-original config for RAID 1+0? Another point "If you want to move an array to another controller, you must also consider the following additional limitations: • All drives in the array must be moved at the same time." I want to move one hdd from each RAID 1 pair. to have mirrors untouched just in case. Do they mean to move all 4 simultaniously? Smart Array 6i User Guide: Moving Drives and Arrays You can move drives to other ID positionson the same array controller. You can also move a complete arrayfrom one controller to another, even if the controllers are on different servers. Before you move drives, the following conditions must be met: • If moving thedrives to a different server, the new server must have enough empty bays to accommodate all the drives simultaneously. • The move will not result in more than 14 physical drives per controller channel. • No controller will be configured with more than 32 logical volumes. • The array has no failed or missing drives. • The array is in its original configuration. • The controller is not reading from or writing to any of the spare drives in the array. • The controller is not running capacity expansion, capacity extension, or RAID or stripe size migration. • The controller is using the latestfirmware version (recommended). If you want to move an array to another controller, you must also consider the following additional limitations: • All drives in the array must be moved at the same time. • In most cases, a moved array (and the logical drives that it contains) can still undergo arraycapacity expansion, logical drive capacity extension, or migration of RAID level orstripe size. When all the conditions have been met: Back up all data before removing any drives or changing configuration. This step is requiredif you are moving data-containing drives from a controller that does not have a battery-backed cache. Power down the system. If you are moving an array from a controller that contains a RAID ADG logical volume to a controller that does not support RAID ADG: Move the drives. Power up the system. If a 1724 POST message is displayed, drive positions were changed successfully and the configuration was updated. If a 1785 (NotConfigured)POST message is displayed: a. Power down the system immediately to prevent data loss. b. Return the drives to their original locations. c. Restore the data from backup, if necessary. Check the new drive configuration byrunning ORCA or ACU ("Configuring an Array" on page 9).

    Read the article

  • Copy from CDROM is very slow in Ubuntu

    - by ???
    I'm using the command to copy CDROM image: # dd if=/dev/sr0 of=./maverick.iso But it's very slow, at about 350k bytes/sec. I've searched the google, and try the command # hdparm -vi /dev/sr0 /dev/sr0: HDIO_DRIVE_CMD(identify) failed: Bad address IO_support = 1 (32-bit) readonly = 0 (off) readahead = 256 (on) HDIO_GETGEO failed: Inappropriate ioctl for device Model=DVD-ROM UJDA775, FwRev=DA03, SerialNo= Config={ Fixed Removeable DTR<=5Mbs DTR>10Mbs nonMagnetic } RawCHS=0/0/0, TrkSize=0, SectSize=0, ECCbytes=0 BuffType=unknown, BuffSize=unknown, MaxMultSect=0 (maybe): CurCHS=0/0/0, CurSects=0, LBA=yes, LBAsects=0 IORDY=yes, tPIO={min:180,w/IORDY:120}, tDMA={min:120,rec:120} PIO modes: pio0 pio1 pio2 pio3 pio4 DMA modes: sdma0 sdma1 sdma2 mdma0 mdma1 mdma2 UDMA modes: udma0 udma1 *udma2 AdvancedPM=no Drive conforms to: ATA/ATAPI-5 T13 1321D revision 3: ATA/ATAPI-1,2,3,4,5 * signifies the current active mode Seems like DMA is already on. And a device test gives: # hdparm -t /dev/sr0 /dev/sr0: Timing buffered disk reads: 2 MB in 6.58 seconds = 311.10 kB/sec # sudo hdparm -tT /dev/sr0 /dev/sr0: Timing cached reads: 2 MB in 2.69 seconds = 760.96 kB/sec Timing buffered disk reads: m 4 MB in 5.19 seconds = 789.09 kB/sec The CD-ROM device and disc should be okay because I can copy it very fast in Windows, using UltraISO utility. So I guess there is something not configured right in Ubuntu, is it?

    Read the article

  • How to tell which process is hogging my CPU when they don't add up to 100%?

    - by endolith
    Ubuntu's System Monitor applet shows 100% CPU usage continuously. If I click it, the resources tab shows it at 100% continuously, too. If I go to processes, though, to find out which process is the culprit, there is nothing above 10%. If I run top there is nothing above 10%. The individual processes do not add up to 100%. I try killing lots of processes, but the overall usage continues to be 100%. How can I find out what's hogging the CPU? This is an unusual situation on a computer I use daily, which is never anywhere near 100% CPU unless I'm doing something that requires it (like loading 32 Firefox tabs), after which it goes back to a normal idle level. It's not a new install or anything. There is no reason the processor should be maxed out. I'm not sure when it started or if I changed something that caused it to happen. Normally I would use top or System Monitor and find the process that had gone out of control, but I can't find anything with those tools this time. It persists after reboots and everything. And the processor is obviously hot, so it's not an erroneous reading. Update: I tried killing every process, one at a time, until the problem went away, and killing vino-server finally fixed it, even though that process never went above 5%. I had enabled Remote Desktop a few days ago (and have obviously now disabled it). But the question remains: How did a single process manage to use 100% CPU while top only showed that process at 5%? How do I identify culprits like this in the future? Looks like I'm not the only one who's had this problem: Still a problem in both jaunty & karmic. Interestingly, both System Monitor & htop do not show the sum of individual processes being anywhere near 100% cpu.

    Read the article

  • Cannot login to ISCSI Target - hangs after sending login details

    - by Frank
    I have an ISCSI target volume, to which i am trying to connect using CentOS Linux server. Everything works fine, but cannot its stuck at login. Here are the steps i am performing: [root@neon ~]# iscsiadm -m node -l iscsiadm: could not read session targetname: 5 iscsiadm: could not find session info for session20 iscsiadm: could not read session targetname: 5 iscsiadm: could not find session info for session21 iscsiadm: could not read session targetname: 5 iscsiadm: could not find session info for session22 iscsiadm: could not read session targetname: 5 iscsiadm: could not find session info for session23 iscsiadm: could not read session targetname: 5 iscsiadm: could not find session info for session30 iscsiadm: could not read session targetname: 5 iscsiadm: could not find session info for session31 iscsiadm: could not read session targetname: 5 iscsiadm: could not find session info for session78 iscsiadm: could not read session targetname: 5 iscsiadm: could not find session info for session79 iscsiadm: could not read session targetname: 5 iscsiadm: could not find session info for session80 iscsiadm: could not read session targetname: 5 iscsiadm: could not find session info for session81 Logging in to [iface: eql.eth2, target: iqn.2001-05.com.equallogic:0-8a0906-ab4764e0b-55ed2ef5cf350a66-neon105, portal: 10.10.1.1,3260] (multiple) After this step, its stucks, waits for some time and then gives this output: Logging in to [iface: iface1, target: iqn.2001-05.com.equallogic:0-8a0906-ab4764e0b-55ed2ef5cf350a66-neon105, portal: 10.10.1.1,3260] (multiple) iscsiadm: Could not login to [iface: eql.eth2, target: iqn.2001-05.com.equallogic:0-8a0906-ab4764e0b-55ed2ef5cf350a66-neon105, portal: 10.10.1.1,3260]. My iscsi.conf is this: node.startup = automatic node.session.timeo.replacement_timeout = 15 # default 120; RedHat recommended node.conn[0].timeo.login_timeout = 15 node.conn[0].timeo.logout_timeout = 15 node.conn[0].timeo.noop_out_interval = 5 node.conn[0].timeo.noop_out_timeout = 5 node.session.err_timeo.abort_timeout = 15 node.session.err_timeo.lu_reset_timeout = 20 node.session.initial_login_retry_max = 8 # default 8; Dell recommended node.session.cmds_max = 1024 # default 128; Equallogic recommended node.session.queue_depth = 32 # default 32; Equallogic recommended node.session.iscsi.InitialR2T = No node.session.iscsi.ImmediateData = Yes node.session.iscsi.FirstBurstLength = 262144 node.session.iscsi.MaxBurstLength = 16776192 node.conn[0].iscsi.MaxRecvDataSegmentLength = 262144 discovery.sendtargets.iscsi.MaxRecvDataSegmentLength = 32768 node.conn[0].iscsi.HeaderDigest = None node.session.iscsi.FastAbort = Yes Also, in access control, i have given full access to Any IP, Any CHAP user and fixed iscsi initiator name. With same access level, all other volumes on rest of servers are working, except this one.

    Read the article

  • Intel Rapid Storage / Smart Response SSD caching issue

    - by goober
    Background Recently built my own PC. It works! Almost. It's been a while since getting into the guts of these things, so I'm familiar but may be missing something simple. FYI, I don't care about blowing the OS away -- it's brand new and we can go back from scratch as many times as necessary. Goal / Issue I'd like to use the SSD to take advantage of Intel's Smart Response technology (allows the SSD to act as a cache for HDDs) I would like the SSD cache to act as a cache for my HDDs, which I would like to be in a RAID1 array (so I get the speed from the SSD and the redundancy from the RAID1) However, Windows only sees the drive in device manager (not as a drive), so I'm unsure what to do about that. Related: as far as I know, for this to work, the drives all have to be in a single RAID array (i.e. a RAID0 pairing of the SSD and the RAID1 HDD array). However, when attempting this at the BIOS level, I am told there is not enough space for an array. Steps so Far Moved the SSD onto the Intel controller (I'd had it on the Marvel 6.0 controller instead of the Intel controller, so the BIOS was only seeing it in a strange way) Updated the BIOS of the motherboard to the latest version Reinstalled Intel's RST (iRST?) software several times, as some forums reported it working after reinstalling 3 times (which does not inspire confidence). Checked Intel storage: it does see the SSD as a physical, non-RAID device. However, it says no space exists if I try to create an array. Checked the BIOS: it does not show up in the boot order, but is an option that can be selected under boot options. Tried the firmware update for that model. Issue: the firmware CD doesn't detect a drive; maybe the Intel storage controller is making it difficult? moved the ssd to the marvel controller. The firmware update cd appeared to hang while searching for drives. swapped out the SATA cable for the manufacturer's and moved back to the intel storage controller. Noticed at this point that in the Intel RST software, a device DOES show up in addition to the RAID set -- only shown as a "60 GB internal disk". Windows doesn't appear to see it as a drive, but it does still show in device manager. Move SSD to port from 0-3 on MOBO and set SATA mode to IDE (after disconnecting RAID1 config) to allow the firmware update to work. Firmware was already at the latest version. Next Steps ? Components involved ASUS P8Z68-V PRO motherboard (Intel Z68 Chipset) Intel i7 2600k Processor 2 x 1TB 7200 RPM HDDs 64 GB Crucial M4 SSD (M4-CT064M4SSD2) For Reference -- Storage Configuration Intel 3 gbps Intel 3gbps Intel 6gbps Marvel 6gbps +----------+ +----------+ +----------+ +----------+ | | <----+ | | +-+ | | | |----------| | |----------| |-|--------| |----------| | | | | + | | | | | | +----------+ | +--|-------+ +-|--------+ +----------+ | | | + v v | 1 TB HDD 64 GB SSD + +> 1 TB HDD For Reference -- Intel RST (v10.8.0.1003) Screenshot Don't mind the "rebuilding" -- knocked a power cable out at one point; it's doing its job, not an indicator of a bad HDD. Any thoughts? Thanks in advance for any help!

    Read the article

  • Exchange server issues - can't upgrade to SP3 - trying to migrate to Exchange 2010

    - by Keith
    Our Exchange server is having a lot of issues. It can't get Windows Updates anymore (error 8000FFFF) and it has a lot of other issues that are all related (Server Manager error - Catastrophic failure exception hresult 8000FFFF). Everything I've read online about it says you pretty much have to re-install Windows to fix it. Because of that, we are going to migrate to a new server running Exchange 2010. I have the new server ready and I was doing the pre-requisite checker and it was complaining that the Exchange 2007 installation wasn't SP2 or newer. I checked and indeed, it is SP1. So I am trying to upgrade the Exchange 2007 installation to SP3, however, it is failing. It is hanging on "Removing Exchange files." I followed these instructions and it's still not working. I can get to the part where you run the upgrade from command line but it starts asking for the exchangeserver.msi file. I point it to where it is located but it keeps asking for it. I am starting to get concerned that I can't upgrade the Exchange server because of the same issues above. My next step is to call Microsoft about the issue because I need to get it fixed however I wanted to check here first.

    Read the article

  • centos TCP/IP connection very slow

    - by yuli chika
    I have a VSP (centos6.1 64bit) with 4gb ram. It always runs well, but in recent few days, the server become slowly. open a small css file need 22 seconds(2kb). tested in home/office/phone with (IE,chrome,safari,firefox). see in firebug networking DNS Lookup ?4?ms Connecting ?21.18?s Sending 1?ms Waiting ?115?ms Receiving ?9?ms The connection cost 21.18 seconds I have checked all the log file, there have no error. top commond, still have free memory. top - 00:23:15 up 8 days, 3:57, 1 user, load average: 3.60, 3.42, 3.83 Tasks: 221 total, 4 running, 217 sleeping, 0 stopped, 0 zombie Cpu(s): 19.3%us, 3.2%sy, 0.0%ni, 76.1%id, 1.4%wa, 0.0%hi, 0.0%si, 0.0%st Mem: 4194304k total, 3247724k used, 946580k free, 0k buffers Swap: 0k total, 0k used, 0k free, 0k cached PID USER PR NI VIRT RES SHR S %CPU %MEM TIME+ COMMAND 32357 mysql 15 0 3710m 835m 6268 S 34.5 20.4 39:14.40 mysqld 9780 apache 15 0 442m 59m 12m S 33.2 1.4 0:05.69 httpd 9842 apache 15 0 403m 26m 10m S 16.9 0.7 0:01.23 httpd 9847 apache 15 0 412m 45m 22m R 15.3 1.1 0:01.00 httpd 9834 apache 15 0 426m 46m 11m R 13.0 1.1 0:02.22 httpd 9891 apache 15 0 407m 43m 19m S 8.0 1.1 0:00.33 httpd 9845 apache 15 0 414m 51m 24m S 6.0 1.3 0:01.53 httpd 9827 apache 15 0 402m 28m 11m S 3.3 0.7 0:02.69 httpd 9768 apache 16 0 414m 51m 24m S 3.0 1.3 0:06.51 httpd 9889 root 15 0 211m 12m 8160 S 2.7 0.3 0:00.32 php 9702 apache 15 0 415m 55m 26m S 1.7 1.4 0:10.67 httpd 9844 apache 15 0 413m 47m 21m S 1.7 1.2 0:01.21 httpd 9697 apache 15 0 414m 51m 24m S 1.3 1.3 0:11.05 httpd 9778 apache 15 0 414m 53m 25m S 1.3 1.3 0:05.38 httpd 9772 apache 15 0 414m 51m 23m R 0.7 1.3 0:05.04 httpd 9823 apache 15 0 415m 50m 23m S 0.7 1.2 0:03.97 httpd 9837 apache 15 0 402m 27m 11m S 0.3 0.7 0:01.04 httpd Then, how to check where is the problem and fixed it? I haven't change and config files in these days. Thanks.

    Read the article

  • Acer LCD says "no signal"

    - by Ken
    I have an Acer 24" LCD (model "AL2423WDR") that's about 3 years old. It worked perfectly for most of its lifetime so far. Recently it started giving problems. When I turn it on, it either says "no signal" on the display, or the power light goes yellow (as if in power-saving mode). This happens with both DVI and VGA (both of which worked fine before), and stranger still, the 4 buttons on the front, for accessing the on-screen menus, don't do anything. I've also tried different computer hardware and software (PC/Mac, Linux/MacOS), but nothing has worked. I've tried power-cycling it (with both the power button and the power switch), and also unplugging it entirely. The nonworking buttons suggest to me an issue with the firmware. I found a place on Acer's website that says I can send it in to have it fixed, at my expense, but I'll avoid that if I can. Is there a way to fully reset it manually? Or is there something else I can try?

    Read the article

  • windows 7: Event 55 The file system structure on the disk is corrupt and unusable

    - by Radio
    Here is a real bad one! Windows 7 RTM with SP1 installed [Version 6.1.7601]. Recently tried to delete some folder on my hard drive and Windows prompted "Error 0x80070570: The file or directory is corrupted and unreadable", and at the same time placed an Event 55 describing "The file system structure on the disk is corrupt and unusable. Please run the chkdsk utility on \Device\HarddiskVolume2." Ran chkdsk, first with /f option, then with /r option. Result in both cases was: no errors found, 0 bad sectors. No problems chkdsk found at all! Went through StackExchange, Google and spent over 6 hours on this. Still cannot figure out the problem. Re-installing/Re-Formatting is not an option! What did I try: Hotfix - Windows6.1-KB982927-x64.msu - gave me an error about incompatibility with my computer, however it totally matches my system. CRC of hotfix was ok. Windows Repair Console found startup errors and fixed those, but this didn't help an issue, even by running chkdsk c: /R from it. http://support.microsoft.com/kb/246026 does not promise anything good. sfc /scannow does not help too. Replaced hard drive by cloning an old one using True Image, repeated all steps above. At the same time, some minor glitches started to appear in my Windows, like side panel and notification area settings are getting reset. Goal is to delete the folder and get rid of Event 55. Sounds like NTFS bug. Please help. This is completely ridiculous.

    Read the article

  • Installing Ruby 1.9.3 OSX 10.7.4 breaks after altering PATH

    - by R V
    I was having trouble installing ruby 1.9.3-p194 from ruby 1.8.7 on my mac osx 10.7.4. I have was trying to fix my homebrew after running "brew doctor" and got the message of "/usr/bin occurs before /usr/local/bin This means that system-provided programs will be used instead of those provided by Homebrew. The following tools exist at both paths: c++-4.2 cpp-4.2 erb g++-4.2 gcc-4.2 gcov-4.2 gem i686-apple-darwin11-cpp-4.2.1 i686-apple-darwin11-g++-4.2.1 i686-apple-darwin11-gcc-4.2.1 irb rake rdoc ri ruby testrb" I fixed it by entering the following, which I found on another stackoverflow answer: export PATH="/usr/local/bin:/usr/local/sbin:~/bin$PATH" Lo and behold! when I typed that ruby updates to 1.9.3-p194. Ruby files seem to compile and run just fine. However, afterward, my navigation around terminal is messed up severely. For instance I can't do the command "open example_file.html" and have the file pop up in Chrome, instead I get the error: "-bash: open: command not found" Also, when I change directory, I get an error, inputting "$ cd desktop" yields the output, "-bash: dirname: command not found" but the directory does then changes... strange. When I exit out of a terminal window all this resets. I'm back to Ruby 1.8.7, have to use the PATH command again to update to 1.9.3, command line navigation gets broken again. Any guidance on how to remedy so I can use 1.9.3-p194 and also have normal terminal navigation would be greatly appreciated.

    Read the article

  • Does NetworkSolutions have a good DNS service?

    - by joxl
    I'm recovering from a DNS disaster and I need some good advice on an alternate solution. My company owns a domain name through NetworkSolutions. Our website is hosted by another company who also maintains our DNS records. Our email is hosted by Google Apps, and the MX records are maintained through the afore-mentioned website/DNS host. Yesterday our website/DNS host had a serious hiccup in some software and completely overwrote all of our DNS records with invalid values; successfully pointing our domain and MX records at the wrong servers. Unfortunately it wasn't caught until it had time to significantly propagate. On top of that, it wasn't fixed until several hours later, combine that with a long TTL on the records; we have customers who are still bouncing emails. Anyhow, I am now completely terrified of this company's ability to do a good job, so I am considering switching to NetworkSolutions for our DNS service. I need the ability to configure A, CNAME, MX, and TXT records, preferably with a nice user interface (our current provider has a poor UI and doesn't support TXT records). Is NetworkSolutions a recommended DNS host? I am a little biased in their direction because the service will be free since we already pay them for our domain name. However I'm curious what others have experienced with their service.

    Read the article

  • Error - "IR Hardware not detected" - but it's installed/working

    - by Robert
    I am trying to do: Settings-TV-Set up TV signal. During this process I am getting the error "IR Hardware not detected." With the remote, I can select the "try again" button (to re-detect) and it tries again, so the remote works. Plugging in the "IR blaster" doesn't change anything. (I wouldn't expect any difference, but I read a post which said you needed that. I will get Media Center to change channels if I can get that working - but first things first.) I was able to do the setup months ago when I had cable. and everything was fine. I just got DirecTV. (BTW - During the above process, Media Center detects the signal coming in on channel 3. Windows XP Media Center SP3. The TV Tuner card is a Pinnacle TCTV HD PCI. Everything - and I mean everything - has the latest firmware and drivers - as of 4 months ago when I fixed a different problem. So I DON"T WANT TO HEAR the standard answer to check drivers/firmware. THANK YOU.) Thanks for any help.

    Read the article

  • Linux DHCPD Mac-Address based Groups

    - by GruffTech
    Our Current DHCPD.conf looks like the following. subnet 10.0.32.0 netmask 255.255.255.0 { range 10.0.32.100 10.0.32.254; option subnet-mask 255.255.255.0; option broadcast-address 10.0.32.255; option domain-name-servers 208.67.222.222,208.67.220.220; option routers 10.0.32.5; host Dev-ABaird-W { hardware ethernet 00:1D:09:3E:49:13; fixed-address 10.0.32.94; } ... more static hosts .... } About as basic as it gets. The old router is 10.0.32.1, our company wanted to implement a squid proxy to better monitor web traffic while at work, and if necessary block large time-wasters, IE Facebook.com. However, we've quickly realized that this change has played a mean prank on our Polycom SIP Phones. Occasionally our phones will not ring, the end recipient hears ringing (this is artificially created by our PBX) however the handset never rings. The ONLY thing that has changed in our network is the option routers line. So, Since all Polycom MAC addresses begin with 00:04:F2 would it be possible in DHCP to say any 00:04:F2:::* MAC addresses get option routers 10.0.32.1, and anything else must talk with our Gateway?

    Read the article

  • Getting old bluetooth headset out of standby on Windows 7

    - by luagh45
    I think this is the problem, and if not, I'm open to suggestions. I have an old Jabra BT200 that I used to use on my phone. When a phone call was coming in it would beep using its own noises (meaning the phone never rang inside the headset) and then I could push the 'answer/hang up' button and sound and mic would start working. I have now paired it with Windows 7, and it looks good. Under the playback menu I have 'Bluetooth Hands free Audio / Jabra BT200 (Mono Audio) / Ready', and under the recording menu I have 'Bluetooth Audio Input Device / Jabra BT200 (Mono Audio) / Ready'. However when I try to test the speakers Windows sends a sound, but I never hear it, and when I talk in the mic, Windows never hears me. If I right click either the Bluetooth mic or speakers there's an option to 'Connect', but it's grayed out and I cannot click it. As the final piece of knowledge I have, my headset blinks once every 3 seconds when it's in standby and I can't get that to change. If everything was working it should blink once every second at which point I think all of my problems would be fixed. Hence my issue: I can't seem to get my headset out of standby. On my headset I've tried sending it test noises and then pressing the 'Answer' button, but still nothing. The headset beeps when I press it, so it works, it just doesn't ever come out of standby. Is there maybe some way to trick my headset into thinking it's getting a phone call from my computer?

    Read the article

  • Google Apps Sync bloated PST file to 14GB

    - by James S
    Back story: I have Outlook connected to my Google Apps email and noticed that some mail never got migrated from my original PST file. I found some VBA code online that compares mail in different PST folders, modified it to find missing and copy those to the target folder. I ran it folder by folder and moved missing mail. Before the exercise the Google Apps PST was about ~4GB and after it was ~4.7GB. Problem: I left Outlook open so Google Sync can copy it online. 24 hours later the Google Apps PST file bloated to 14GB+ and none of the mail has been synced to the cloud. I know that there should be at most ~5GB of mail. Why is the rest of the space being taken up? Funny thing is Gmail shows 3GB as being used online. What I tried: I emptied the deleted items folder and recycling bin I've run Outlook compact PST and it didn't work. I tried SCANPST.exe on the PST and it didn't work. I re-ran compact PST and it didn't work (after SCANPST found and fixed a few errors) Any ideas out there on what caused the problem and how to solve it?

    Read the article

  • How to stop Apache from crashing my entire server?

    - by CyberShadow
    I maintain a Gentoo server with a few services, including Apache. It's fairly low-end (2GB of RAM and a low-end CPU with 2 cores). My problem is that, despite my best efforts, an over-loaded Apache crashes the entire server. In fact, at this point I'm close to being convinced that Linux is a horrible operating system that isn't worth anyone's time looking for stability under load. Things I tried: Adjusting oom_adj for the root Apache process (and thus all its children). That had close to no effect. When Apache was overloaded it would bring the system to a grind, as the system paged out everything else before it got to kill anything. Turning off swap. Didn't help, it would unload memory paged to binaries of processes and other files on /, thus causing the same effect. Putting it in a memory-limited cgroup (limited to 512 MB of RAM, 1/4th of the total). This "worked", at least in my own stress tests - except the server keeps crashing under load (basically stalling all other processes, inaccessible via SSH, etc.) Running it with idle I/O priority. This wasn't a very good idea in the end, because it just caused the system load to climb indefinitely (into the thousands) with almost no visible effect - until you tried to access an unbuffered part of the disk. This caused the task to freeze. (So much for good I/O scheduling, eh?) Limiting the number of concurrent connections to Apache. Setting the number too low caused web sites to become unresponsive due to most slots being occupied with long requests (file downloads). I tried various Apache MPMs without much success (prefork, event, itk). Switching from prefork/event+php-cgi+suphp to itk+mod_php. This improved performance, but didn't solve the actual problem. Switching I/O schedulers (cfq to deadline). Just to stress this out: I don't care if Apache itself goes down under load, I just want the rest of my system to remain stable. Of course, having Apache recover quickly after a brief period of intensive load would be great to have, but one step at a time. Right now I am mostly dumbfounded by how can humanity, in this day and age, design an operating system where such a seemingly simple task (don't allow one system component to crash the entire system) seems practically impossible - or at least, very hard to do. Please don't suggest things like VMs or "BUY MORE RAM". Some more information gathered with a friend's help: The processes hang when the cgroup oom killer is invoked. Here's the call trace: [<ffffffff8104b94b>] ? prepare_to_wait+0x70/0x7b [<ffffffff810a9c73>] mem_cgroup_handle_oom+0xdf/0x180 [<ffffffff810a9559>] ? memcg_oom_wake_function+0x0/0x6d [<ffffffff810aa041>] __mem_cgroup_try_charge+0x32d/0x478 [<ffffffff810aac67>] mem_cgroup_charge_common+0x48/0x73 [<ffffffff81081c98>] ? __lru_cache_add+0x60/0x62 [<ffffffff810aadc3>] mem_cgroup_newpage_charge+0x3b/0x4a [<ffffffff8108ec38>] handle_mm_fault+0x305/0x8cf [<ffffffff813c6276>] ? schedule+0x6ae/0x6fb [<ffffffff8101f568>] do_page_fault+0x214/0x22b [<ffffffff813c7e1f>] page_fault+0x1f/0x30 At this point, the apache memory cgroup is practically deadlocked, and burning CPU in syscalls (all with the above call trace). This seems like a problem in the cgroup implementation...

    Read the article

  • Computer makes hissing noise, turns off after few seconds

    - by Kaustubh P
    I have a problem similar to the questions posted here and here. This is my config: Asus M3N78-EM, with AMD Phenom X3 720 2800 Black Edition, 4GB Transcend DDR2 RAM, Nvidia 9400GT. HD is a 160 GB IDE, and a LG IDE DVD-ROM. The power button is a bit off, I have removed the cover of the switch, and the only way it turns on is just giving the "stick" under the cover a gentle press. It turns on sometimes, and at other times, I have to cut-off the power from the PSU, and try again. I will describe my problem in as detail as possible, please bear with me: The problem has started in the last week, a few months after I changed the to the powerswitch arrangement as described above. The PC makes a hissing noise, and I wasn't able to pin-point the noise source, because of the various other fans. At first, removing the HD, rebooting w/o the HD, turning it off, reconnecting and booting made the problem go away. But of late, it doesn't happen. As suggested in the other questions, I tried reducing the load by disconnecting both the IDE drives, and the problem (noise + turn-off) still occurs. I also connected another 80G IDE HD,today morning, adn it still made that noise, and turned off. I also opened up the PSU, but I couldn't see any fault in that, I tried rotating the fan by blowing into the blades, and with my fingers, but the hissing noise didn't come from there. Or maybe the speed wasn't enough to evoke that noise. A few weeks ago: I had cleaned the Cabinet and had repasted the processor and its fan using some thermal paste. Could that be at fault? I also used a vacuum to blow the dust out of the PSU, could the power have been too much, to maybe offset the fan or something? A label on the PSU says it uses a ball-bearing fan. That only leaves me with the Processor fan and the processor itself. I didn't try removing the processor fan and processor from the motherboard, and then turning the PC on, fearing damage. Will doing so cause any damage? What can I do to localize and pin-point the problem? Also, after a few tries, the Computer starts up. Sometimes it turns of within 2 seconds, sometimes after the POST. Once it turned off at the grub. Another time it booted completely and then turned off. The only way to ensure that the PC wont turn off, is if the hissing noise stops. EDIT: I suspect it to be the Processor/Processor fan, owing to the source of noise. All the config, except for the Cabinet, is just over a year old. EDIT2: I also just remembered, that I had set the "On-power resume" to turn on, i.e. If I supply he PC with power, it will turn itself on, w/o me needing to press the switch. I had done that to workaround the faulty power-switch, as noted above. EDIT3: I calculated the power my system needs, from the antec site, and I just arrived at 292W

    Read the article

  • How does Linux determine the SCSI address of a disk?

    - by Chris Sears
    Greetings, I'm working with RHEL 5.5 guest VMs under VMware ESX 4. When I configure the virtual disks in the VM hardware settings, each disk has a SCSI address in the format "N:M". For example, "1:3" would mean SCSI host number 1 and SCSI target ID 3. When I look at the disk info from the VM's BIOS or a Windows OS, the detected SCSI address info matches up with the virtual hardware settings. But under Linux, the SCSI address components don't match up, at least not completely or consistently. I've tried the three supported virtual SCSI and SAS drivers and they all seem to be "broken", but in different ways. Here's a list of the virtual hardware addresses vs what was detected under Linux with each of the drivers: Driver vHW Addr Linux Addr -------- -------- ---------- LSI SAS 0:0 0:0 LSI SAS 0:3 0:1 LSI SAS 0:6 0:2 LSI SCSI 1:1 2:1 LSI SCSI 1:4 2:4 LSI SCSI 1:7 2:7 pvSCSI 2:2 1:2 pvSCSI 2:5 1:5 pvSCSI 2:8 1:8 My main question is why does this happen under Linux? The next question is: how do I get it fixed or fix it myself? If I was going to guess, I'd say it's an issue with how the kernel is handing out the SCSI host number and how the Linux SCSI driver (included with VMware tools) is detecting the SCSI target number. Perhaps the order the drivers are loaded also has something to do with the issue. I'm guessing this would not involve udev, but I could be wrong. Any thoughts would be appreciated. Thanks! PS. My environment is VMware, but I don't need an answer for these drivers specifically. I imagine this might be a problem with any SCSI driver under Linux.

    Read the article

  • Cable management techniques

    - by cornjuliox
    How do you manage the giant jungle of cables behind your PC? When you have 2 or more PCs next to each other, you wind up with this giant mess cables that's a pain in the neck to clean especially when both computers are running 24/7 and any fidgeting with the cables is likely to cause data loss and/or angry users. So far I've tried masking tape, cable ties and plain old string but none have been very effective. The masking tape kept the cables in place, but over time they ended up leaving this awful sticky residue on the sides of the cables that just won't come off gets all over your fingers and is horrible horrible horrible. I have nightmares about that stuff. We used cable ties and 'folded' up some of the longer cables so that they weren't any longer than they needed to be, but this meant that the position of some of our devices like the keyboard and the mouse were essentially 'fixed' until we removed the ties. The string didn't work much differently and required that we tie them properly or risk it coming loose. I would switch to a wireless keyboard and mouse, but I don't want to have to deal with the added expense of batteries, even the rechargable ones. Plus I don't want them to die on me at a crucial moment (happened to me once while playing Firearms _<). How do large offices and data centers manage their masses of cable?

    Read the article

  • Cable management techniques

    - by cornjuliox
    How do you manage the giant jungle of cables behind your PC? When you have 2 or more PCs next to each other, you wind up with this giant mess cables that's a pain in the neck to clean especially when both computers are running 24/7 and any fidgeting with the cables is likely to cause data loss and/or angry users. So far I've tried masking tape, cable ties and plain old string but none have been very effective. The masking tape kept the cables in place, but over time they ended up leaving this awful sticky residue on the sides of the cables that just won't come off gets all over your fingers and is horrible horrible horrible. I have nightmares about that stuff. We used cable ties and 'folded' up some of the longer cables so that they weren't any longer than they needed to be, but this meant that the position of some of our devices like the keyboard and the mouse were essentially 'fixed' until we removed the ties. The string didn't work much differently and required that we tie them properly or risk it coming loose. I would switch to a wireless keyboard and mouse, but I don't want to have to deal with the added expense of batteries, even the rechargable ones. Plus I don't want them to die on me at a crucial moment (happened to me once while playing Firearms _<). I know that there are people out there with home/office networks a thousand times more convoluted than mine, so

    Read the article

  • Lost Permission on Files using wrong chmod syntax Centos 5.5

    - by alloutfallout
    Hello, I was trying to remove write permissions on an entire directory, and I used the incorrect command: chmod 644 -r sites/default I meant to type chmod -R 644 sites/default The result was this: chmod: cannot access `644': No such file or directory $ ls -als sites total 24 4 drwxr-xr-x 5 user group 4096 Jan 11 10:54 . 4 drwxrwxr-x 14 user group 4096 Jan 11 10:11 .. 4 drwxr-xr-x 4 user group 4096 Jan 5 01:25 all 4 d-w------- 3 user group 4096 Jan 11 10:43 default 4 -rw-r--r-- 1 user group 1849 Apr 15 2010 example.sites.php I fixed the permissions on the default folder with $ chmod 644 sites/default But, the following ls shows a all the files with red backgrounds and question marks. I can't access any files unless I am root. $ ls -als sites/default total 0 ? ?--------- ? ? ? ? ? . ? ?--------- ? ? ? ? ? .. ? ?--------- ? ? ? ? ? default.settings.php ? ?--------- ? ? ? ? ? files ? ?--------- ? ? ? ? ? settings.php When I log in as root, I can edit all of the files, and their permissions appear correctly. I do not know how to undo the damage caused by using -r with chmod instead of -R. Any Suggestions?

    Read the article

  • Split MPEG video from command line?

    - by Tim
    I have a homemade DVD that I'm effectively trying to insert chapters into and rearrange - the original author burned it as one long chapter, and I'd like to rip it into smaller pieces and re-encode it into a new DVD. I ripped the DVD with the following command: mplayer dvd:// -dvd-device /dev/sr2 -dumpstream -dumpfile raw.vob I'm running Gentoo Linux with mplayer version 1.0-rc2_p20090731 (the latest available in Portage). I have a list of times that the chapters are supposed to span (for example 30:11-33:25), so my first thought was to rip the entire DVD and use mpgtx to cut out certain pieces of the file. My issue is that running mpgtx -i on the file reports quite a few timestamp jumps: Time stamps jumped from 59.753789 to 0.001622 at position 1d29800 Time stamps jumped from 204963823030450.343750 to 31.165900 at position 2d4f800 Time stamps jumped from 60.077878 to 0.001622 at position 43cc000 Time stamps jumped from 60.024233 to 0.001622 at position 65c5000 Time stamps jumped from 204963823068631.718750 to 52.549244 at position 7fd1000 I've tried to fix the indexes using: mencoder raw.vob -oac copy -ovc copy -forceidx -o fixed.vob -of mpeg But mpgtx will still report timestamp issues. My immediate question: is there a way to take the ripped movie I have and correct its timestamps so I can cut it with mpgtx? If I can get that one issue out of the way, building the rest of the DVD will be smooth sailing. If it's not possible to fix the timestamps on this file: is there a better way to rip small chunks of the DVD into separate files for recompilation later? I'd very much like this to be done on Linux, and it'd be even better if I could script it somehow (feed in a list of start and end positions, or start times and durations, and get out a series of ripped files). If need be, I also have a Mac OS X machine available, but no Windows. Edit: I wound up finding another solution involving HandBrake and ffmpeg (with help from this question), but the question stands. Edit again: Turns out my other solution didn't quite work - the audio desynchronized by about five seconds, in about half of my cut mpgs - so I'm back to square one. Anyone?

    Read the article

  • Nginx: Serve static files out of a given directory - one level too deep

    - by Joe J
    I'm pretty new to nginx configs. I'm having some difficulty with a pretty basic problem. I'd like to host some static files at /doc (index.html, some images, etc). The files are located in a directory called /sites/mysite/proj/doc/. The problem is, is that with the nginx config below, nginx tries to look for a directory called "/sites/mysite/proj/doc/doc". Perhaps this can be fixed by setting the root to /sites/mysite/proj/, but I don't want to potentially expose other (non-static) assets in the proj/ directory. And for various reasons, I can't really move the doc/ directory from where it is. I think there is a way to use a Rewrite rule to solve this situation, but I don't really understand all the parts, so having some difficulty formulating the rule. rewrite ^/doc/(.*)$ /$1 permanent; I've also included a working example of hosting files out of a /sites/mysite/htdocs/static/ directory. > vim locations.conf location /static { root /sites/mysite/htdocs/; access_log off; autoindex on; } location /doc { root /sites/mysite/proj/doc/; access_log on; autoindex on; } 2011/11/19 23:49:00 [error] 2314#0: *42 open() "/sites/mysite/proj/doc/doc" failed (2: No such file or directory), client: 100.100.100.100, server: , request: "GET /doc HTTP/1.1", host: "myhost.com" Does anyone have any ideas how I might go about serving this static content? Any help is much appreciated. Thanks, Joe

    Read the article

< Previous Page | 480 481 482 483 484 485 486 487 488 489 490 491  | Next Page >