  • Arp tries on various *nix based systems.

    - by salparadise
    Does anyone know what determines the amount of arp tries a router will make? I have different behaviors with two devices, if I try to traceroute to a non-existent host on a subnet that belongs to an interface on the router, a Linux box will try to arp 3 times and then return a host un-reacheable icmp message. Junos will continuosly try to arp and not return anything. Is there a sysctl value that determines this or anything at all.

    Read the article

  • PDF Corruption When Sending with Microsoft Products

    - by Winner
    I have the same PDF corruption problem in two different offices that I am the tech support for. Office 1: Started in the middle of December. PDF received from outside the office and is viewable with no problems. I have no control over how it is created. If it is forwarded to anyone else, the PDF is corrupted. I have forwarded it to multiple people in the office. I have tried viewing with Reader 8, 9, Sumatra and Fox IT. I have tried forwarding to Gmail and their viewer says it is corrupted. If I save the PDF and create a new email, it will be corrupted when sent using Outlook 2003, Outlook 2007, Microsoft Live Mail and Outlook Express. If I create the email using Thunderbird 3, Gmail or the webclient Iclient for IPSwitch IMail it will not be corrupted. I have confirmed the same results when using our IMail SMTP and also Using Gmail as the SMTP server. To be clear, if I created in Thunderbird, Gmail or Iclient and received on any of the MS products, it will be viewable. This office receives PDFs daily from multiple sources. There is only a small subset that are having this problem. So far they problem PDFs are from two different companies they deal with, but not all of the PDFs are bad. Office 2: PDFs are created by a management system. I'm not sure what engine is used to create them. Same exact same issues. At both offices, I noticed that the file size is wrong. One small PDF the proper file size is 12kb for the PDF when it's viewable, when it shows up corrupted it is only 8kb. We handle the email for both offices. Both are POP servers, not Exchange. IMail was updated after these issues start. I have tried different SMTP servers and it still seems to happen only when using Microsoft products to send. Anyone else having problems with PDFs getting corrupted? Any ideas how to find out a resolution?

    Read the article

  • RSH between servers not working

    - by churnd
    I have two servers: one CentOS 5.8 & one Solaris 10. Both are joined to my workplace AD domain via PBIS-Open. A user will log into the linux server & run an application which issues commands over RSH to the solaris server. Some commands are also run on the linux server, so both are needed. Due to the application these servers are being used for (proprietary GE software), the software on the linux server needs to be able to issue rsh commands to the solaris server on behalf of the user (the user just runs a script & the rest is automatic). However, rsh is not working for the domain users. It does work for a local user, so I believe I have the necessary trust settings between the two servers correct. However, I can rlogin as a domain user from the linux server to the solaris server. SSH works too (how I wish I could use it). Some relevant info: via rlogin: [user@linux~]$ rlogin solaris connect to address 192.168.1.2 port 543: Connection refused Trying krb4 rlogin... connect to address 192.168.1.2 port 543: Connection refused trying normal rlogin (/usr/bin/rlogin) Sun Microsystems Inc. SunOS 5.10 Generic January 2005 solaris% via rsh: [user@linux ~]$ rsh solaris ls connect to address 192.168.1.2 port 544: Connection refused Trying krb4 rsh... connect to address 192.168.1.2 port 544: Connection refused trying normal rsh (/usr/bin/rsh) permission denied. [user@linux ~]$ relevant snippet from /etc/pam.conf on solaris: # # rlogin service (explicit because of pam_rhost_auth) # rlogin auth sufficient pam_rhosts_auth.so.1 rlogin auth requisite pam_lsass.so set_default_repository rlogin auth requisite pam_lsass.so smartcard_prompt try_first_pass rlogin auth requisite pam_authtok_get.so.1 try_first_pass rlogin auth sufficient pam_lsass.so try_first_pass rlogin auth required pam_dhkeys.so.1 rlogin auth required pam_unix_cred.so.1 rlogin auth required pam_unix_auth.so.1 # # Kerberized rlogin service # krlogin auth required pam_unix_cred.so.1 krlogin auth required pam_krb5.so.1 # # rsh service (explicit because of pam_rhost_auth, # and pam_unix_auth for meaningful pam_setcred) # rsh auth sufficient pam_rhosts_auth.so.1 rsh auth required pam_unix_cred.so.1 # # Kerberized rsh service # krsh auth required pam_unix_cred.so.1 krsh auth required pam_krb5.so.1 # I have not really seen anything useful in either system log that seem to be directly related to the failed login attempt. I've tail -f'd /var/adm/messages on solaris & /var/log/messages on linux during the failed attempts & nothing shows up. Maybe I need to be doing something else?

    Read the article

  • Remove identifying information from SSH.

    - by The Rook
    When I do an nmap -sV 127.0.0.1 -p 22 of my system I get the following information: SF-Port22-TCP:V=4.62%I=7%D=11/9%Time=4916402C%P=i686-pc-linux-gnu%r(NULL,2 SF:7,"SSH-2.0-OpenSSH_5.1p1\x20Debian-3ubuntu1\r\n"); How do I go about chaining these two pieces of information? i686-pc-linux-gnu and SSH-2\.0-OpenSSH_5\.1p1\x20Debian-3ubuntu1.

    Read the article

  • How to setup a Wi-Fi 2-computer network with Internet sharing?

    - by Narek
    I have the following devices: Desktop Computer (Windows XP Professional) Laptop Computer (Windows Vista Home Premium) A USB modem that I want to connect to my Desktop computer (so my Desktop has Internet) And a Wi-Fi router (D-Link, model: DIR-300) that I want to use in order to create a connection between mentioned two computers to be able to share files and what is the most important thing to make my laptop to have access to the Internet. What steps I should do to have this system?

    Read the article

  • Real time writing to disk

    - by Jesper
    Is there any software out there that can help me track, in real time, files being changed and/or created on my Windows (Windows 7) system? I'm trying to figure out all files being changed when setting up Windows Live Mail as I want to sync all relevant files between two computers. And no, the storage folder is not enough. I'm grateful for any help. Thanks!

    Read the article

  • Combine lighttpd configs for IPv4 and IPv6

    - by mrothe
    My lighttpd.conf includes the following lines: $SERVER["socket"] == "188.40.236.66:443" { ssl.engine = "enable" ssl.ca-file = "/etc/lighttpd/ssl/startcom.ca.pem" ssl.pemfile = "/etc/lighttpd/ssl/www.unixforces.net.pem" } $SERVER["socket"] == "[2a01:4f8:100:30a5:0:bc28:ec43:2]:443" { ssl.engine = "enable" ssl.ca-file = "/etc/lighttpd/ssl/startcom.ca.pem" ssl.pemfile = "/etc/lighttpd/ssl/www.unixforces.net.pem" } Is it possible to combine these two blocks into one? $SERVER["socket"] only allows for == and not =~.

    Read the article

  • Windows 8 permissions (CHMOD) with XAMPP

    - by Alex Gorcea
    While I know that CHMOD is impossible in Windows, I do have a problem with permissions. I'm running XAMPP on Windows 8 Release Preview and I'm trying to install ModenaCam. However, I get an error message which tells me that two files are not writable (they are 666) and they need to be 777. The permissions for the files are correct (full control for everyone, owner is everyone), but I can't get this thing to work! Any help would be greatly appreciated.

    Read the article

  • How to move Exchange 2003 mailbox or store from 2003 to 2007 on separate networks?

    - by David
    I have an exchange sever 2003 installed and working. I have a new exchange 2007 server on another network. The two networks are completely separate with no connection. How can I take the 2003 mailboxes and put them on the new 2007 system? The move mailbox normal option on 2007 will not be able to see the old 2003 exchange server. I was hoping I could just copy the database and mount it, but this doesnot seem to work. Thanks

    Read the article

  • What are pros and cons of logrotate vs rotatelogs with Apache?

    - by Mohan Gulati
    Apache provides a tool called rotatelogs which has the benefit of not restarting apache when rotating logs which happens with logrotate. I do not have enough experience to speak if this is enough criteria to use rotatelogs over logrotate. My questions is does anyone have real life experience using either or of these two tools and what were your input would be? What would you recommend and why?

    Read the article

  • Any issues with computer on one domain in a separate forest and user account in another domain/forest?

    - by TheCleaner
    I have a few of my sites with a trust relationship among two different forests with a single domain in each AD forest. I'll skip all the politics and details that don't matter and just ask the question: Will having a machine with a computer account in one domain and their user account in another cause any issues? (besides GPO behavior that would need to be understood such as their computer getting a GPO applied from the computer's domain, and their user account getting a GPO applied from their user domain)

    Read the article

  • NLB Accessed Denied from second server

    - by Igor K
    Hello Have NLB set up and working. Just two servers, web1 and web2. I set up NLB on web1 and can view both machines as Converged. (I had to specify a login/pass to connect to web2). On web2, looking at the NLB Manager, it only shows web2 and says in the log "Accessed Denied. Error connecting to web1". Any ideas how to fix?

    Read the article

  • What exactly is the difference between update-manager -d and the process

    - by jldugger
    The official recommendation of Ubuntu is to use sudo do-release-upgrade to do an online upgrade from one version to the next. Historically many of my Debianite friends and myself have simply altered apt's sources.list and run apt-get dist-upgrade. I follow Ubuntu's recommendations, but I've always wondered what the magic difference between these two processes is. What, exactly, does do-release-upgrade do, on say an upgrade from 9.04 to 9.10? (Examples from other releases welcome.)

    Read the article

  • .htaccess - Too many redirects

    - by Knocks X
    I am getting a "too many redirects" error from the following two .htaccess files. .htaccess on domain 1 Redirect 301 / http://www.domain2.com/ .htaccess on domain 2 RewriteEngine On RewriteBase / RewriteCond %{HTTP_HOST} !^www\. RewriteRule (.*) http://www.%{HTTP_HOST}/$1 [L,R] RewriteCond %{REQUEST_FILENAME} !-f RewriteCond %{REQUEST_FILENAME} !-d RewriteRule .* /forum/ [L,R] RedirectMatch permanent ^/$ /forum/ # Options +FollowSymlinks RewriteCond %{HTTP_REFERER} badsite1\.com [NC,OR] RewriteCond %{HTTP_REFERER} badsite2\.com [NC] RewriteRule .* - [F] Anyone know the reason for the too many redirects error?

    Read the article

  • Motherboard jumper setting: BIOS flash write protection.

    - by Wesley
    I have an ECS P4M800PRO-M478 motherboard and I'm just setting up the jumpers right now, of which there are only two sets. One is the CLR_CMOS jumper, which is set to Normal, of course. However, there is another set called BIOS_WP which controls whether BIOS flash writing is protected or unprotected. Which setting should I have it set at and would this affect any BIOS flashes in the future?

    Read the article

  • Fibre channel long distance woes

    - by Marki
    I need a fresh pair of eyes. We're using a 15km fibre optic line across which fibrechannel and 10GbE is multiplexed (passive optical CWDM). For FC we have long distance lasers suitable up to 40km (Skylane SFCxx0404F0D). The multiplexer is limited by the SFPs which can do max. 4Gb fibrechannel. The FC switch is a Brocade 5000 series. The respective wavelengths are 1550,1570,1590 and 1610nm for FC and 1530nm for 10GbE. The problem is the 4GbFC fabrics are almost never clean. Sometimes they are for a while even with a lot of traffic on them. Then they may suddenly start producing errors (RX CRC, RX encoding, RX disparity, ...) even with only marginal traffic on them. I am attaching some error and traffic graphs. Errors are currently in the order of 50-100 errors per 5 minutes when with 1Gb/s traffic. Optics Here is the power output of one port summarized (collected using sfpshow on different switches) SITE-A units=uW (microwatt) SITE-B ********************************************** FAB1 SW1 TX 1234.3 RX 49.1 SW3 1550nm (ko) RX 95.2 TX 1175.6 FAB2 SW2 TX 1422.0 RX 104.6 SW4 1610nm (ok) RX 54.3 TX 1468.4 What I find curious at this point is the asymmetry in the power levels. While SW2 transmits with 1422uW which SW4 receives with 104uW, SW2 only receives the SW4 signal with similar original power only with 54uW. Vice versa for SW1-3. Anyway the SFPs have RX sensitivity down to -18dBm (ca. 20uW) so in any case it should be fine... But nothing is. Some SFPs have been diagnosed as malfunctioning by the manufacturer (the 1550nm ones shown above with "ko"). The 1610nm ones apparently are ok, they have been tested using a traffic generator. The leased line has also been tested more than once. All is within tolerances. I'm awaiting the replacements but for some reason I don't believe it will make things better as the apparently good ones don't produce ZERO errors either. Earlier there was active equipment involved (some kind of 4GFC retimer) before putting the signal on the line. No idea why. That equipment was eliminated because of the problems so we now only have: the long distance laser in the switch, (new) 10m LC-SC monomode cable to the mux (for each fabric), the leased line, the same thing but reversed on the other side of the link. FC switches Here is a port config from the Brocade portcfgshow (it's like that on both sides, obviously) Area Number: 0 Speed Level: 4G Fill Word(On Active) 0(Idle-Idle) Fill Word(Current) 0(Idle-Idle) AL_PA Offset 13: OFF Trunk Port ON Long Distance LS VC Link Init OFF Desired Distance 32 Km Reserved Buffers 70 Locked L_Port OFF Locked G_Port OFF Disabled E_Port OFF Locked E_Port OFF ISL R_RDY Mode OFF RSCN Suppressed OFF Persistent Disable OFF LOS TOV enable OFF NPIV capability ON QOS E_Port OFF Port Auto Disable: OFF Rate Limit OFF EX Port OFF Mirror Port OFF Credit Recovery ON F_Port Buffers OFF Fault Delay: 0(R_A_TOV) NPIV PP Limit: 126 CSCTL mode: OFF Forcing the links to 2GbFC produces no errors, but we bought 4GbFC and we want 4GbFC. I don't know where to look anymore. Any ideas what to try next or how to proceed? If we can't make 4GbFC work reliably I wonder what the people working with 8 or 16 do... I don't assume that "a few errors here and there" are acceptable. Oh and BTW we are in contact with everyone of the manufacturers (FC switch, MUX, SFPs, ...) Except for the SFPs to be changed (some have been changed before) nobody has a clue. Brocade SAN Health says the fabric is ok. MUX, well, it's passive, it's only a prism, nature at it's best. Any shots in the dark? APPENDIX: Answers to your questions @Chopper3: This is the second generation of Brocades exhibiting the problem. Before we had 5000s, now we have 5100s. In the beginning when we still had the active MUX we rented a longdistance laser once to put it into the switch directly in order to make tests for a day, during that day of course it was clean. But as I said, sometimes it's clean just like that. And sometimes it's not. Alternative switches would mean to rebuild the entire SAN with those only to test. Alternative SFPs, well they're hard to come by just like that. @longneck: The line is rented. It's a dark fibre (9um monomode) so there's noone else on it. Sure there are splices. I can't go and look but I have to trust they have been done correctly. As I said the line has been checked and rechecked (using an optical time-domain reflectometer). Obviously you don't have all this equipment yourself because it's way too expensive. @mdpc: What would be the "wrong" type of cable according to you? Up to the switch everything is monomode, yes. The connectors are the correct ones too. Yeah I know there are the green ones where the fibre is cut off at a certain angle etc. But we have the correct ones for all that I know. Progress Report #1 We have had two fabrics (=2x2 switches) with Brocade 5100s with FabricOS 6.4.1 and two fabrics (another 2x4 switches) on FabricOS 7.0.2. On the longdistance ISLs (one in each fabric) it turned out that with FOS 6.4.1 setting it to long distance issues warnings about the VC Init setting and consequently the fill word. But those are only warnings. FOS 7.0.2 requires you to do modifications to VCI and the fillword for long distance links. Setting FOS 6.4.1 to the LS (long-distance static distance) setting with wrong VCI and fillword setting made the whole fabric inoperational (stuck in an SCN loop, use fabriclog -s to see, you don't see it anywhere else, no port error counters or anything increasing). Currently I'm giving the one fabric with the IMHO more correct settings a beating and it seems to do fine, whereas the other one without much traffic still has errors here and there. In short: We have eliminated the active part of the MUX (the FC retimer). We are putting the long distance SFPs into the end equipment themselves. Just to be sure we bought new monomode cables to connect the end equipment to the remaining passive part of the MUX. We are now trying out several long distance configs. It's almost black magic. Everything that happens is mostly empirical, noone seems to have a clue what are the exact reasons to do something. ("We have tried this, and it didn't work, then we tried that and it worked, so we stuck with that." But noone really seems to know why.) I'll keep you updated. Progress Report #2 We got the new lasers for one of the fabrics on warranty. It's ultra clean even on 4GbFC. They're transmitting with roughly 2mW (3dBm) whereas the others are only at 1.5mW (1.5dBm) although that should really be enough. The other fabric (where the lasers are apparently ok) still produces one or two CRCs infrequently. Using sfpshow the SFP producing the actual RX errors shows Status/Ctrl: 0x82 Alarm flags[0,1] = 0x5, 0x40 Warn Flags[0,1] = 0x5, 0x40 Now I'll have to find out what that means. Not sure if it was there before. Well I'll first clear my head with a week of vacation. 8-)

    Read the article

  • unable to join domain using virtualbox

    - by FreshPrinceOfSO
    I'm in the process of setting up a VM environment for a MS certification exam (70-462). Following the training kit's instructions, I've set up a domain controller (DC) and two members (SQL-A, SQL-B) thus far. I can't figure out why I can't join the domain. DC IPv4 Address . . . : 10.10.10.10(Preferred) Subnet Mask. . . . : 255.0.0.0 DNS Servers. . . . : ::1 127.0.0.1 SQL-A IPv4 Address . . . : 10.10.10.20(Preferred) Subnet Mask. . . . : 255.0.0.0 DNS Servers. . . . : 10.10.10.10 SQL-B IPv4 Address . . . : 10.10.10.30(Preferred) Subnet Mask. . . . : 255.0.0.0 DNS Servers. . . . : 10.10.10.10 I've read how to do networking between virtual machines in virtualbox and the documentation. After trying various network adapter configurations, I can't get them to communicate in order to have the two members join the domain. When I ping from .30 to .10, I get: ping 10.10.10.10 Pinging 10.10.10.10 with 32 bytes of data: Reply from 10.10.10.20: Destination host unreachable. Reply from 10.10.10.20: Destination host unreachable. Reply from 10.10.10.20: Destination host unreachable. Reply from 10.10.10.20: Destination host unreachable. Trying to join the domain: netdom join SQL-A /domain:contso.com The specified domain either does not exist or could not be contacted. The command failed to complete successfully. Within VirtualBox, I've tried the following combinations for network adapter: Attached to - Promiscuous Mode ------------------------------- NAT Bridged Adapter - Deny Bridged Adapter - Allow VMs Bridged Adapter - Allow All Internal Network - Deny Internal Network - Allow VMs Internal Network - Allow All Host-only Adapter - Deny Host-only Adapter - Allow VMs Host-only Adapter - Allow All Edit ipconfig /all of DC ipconfig /all of SQL-A

    Read the article

  • Why are my hard drives failing?

    - by WishCow
    I have a small Ubuntu server running at home, with 2 HDDs. There are two software raids (raid1) on the disks, managed by mdadm, which I believe is irrelevant, but mentioning it anyway. Both of the HDDs are Western Digital, and have been used for around 2 years, when one of them started making clicking noises, and died. I figured that maybe it's natural after 2 years, so I bought a new one, and resynced the raid arrays. After about a month, the other drive also died. I didn't get suspicious, since both drives have been bought at the same time, it's not that surprising to see both of them near each other, so I bought another one. So far, 2 old drives failed, and 2 brand new in the system. After one month, one of the new drives died. This is when it started getting suspicious. Since the PC was put together from some really old parts (think AthlonXP), I figured that maybe the motherboard's SATA controller is the culprit. Of course you can't switch parts easily in an old PC like this, so I bought a whole system, new MB, new CPU, new RAM. Took the just failed drive back, since it was under warranty, and got it replaced. So it is up to 2 failed drives from the old ones, and 1 failed drive from the new ones. No problems, for 1 month. After that errors were creeping up again in /var/log/messages, and mdadm was reporting raid array failures. I started tearing my hair out. Everything is new in the system, it's up to the third brand new HDD, it's simply not possible that all of the new drives that I bought were faulty. Let's see what is still common... the cables. Okay, long shot, let's replace the SATA cables. Take HDD back, smile to the guy at the counter and say that I'm really unlucky. He replaces the HDD. I come home, one month passes and one of HDDs fails, again. I'm not joking. Two of the brand new HDDs have failed. Maybe it's a bug in the OS. Let's see what the manufacturer's testing tool says. Download testing tool, burn it to a CD, reboot, leave HDD testing overnight. Test says that the drive is faulty, and I should back up everything, if I still can. I don't know what's happening, but it does not look like a software problem, something is definitely thrashing the HDDs. I should mention now, that the whole system is in a shoebox. Since there are a load of "build your own ikea case" stuff, I thought there shouldn't be any problems throwing the thing in a box, and stuffing it away somewhere. The box is well ventilated, but I thought that just maybe the drives were overheating. There is no other possible answer to this. So I took the HDD back, and got it replaced (for the 3rd time), and bought HDD coolers. And just now, I have heard the sound of doom. click click whizzzzzzzzz. SSH into the box: You have new mail! mail r 1 DegradedArrayEvent on /dev/md0 ... dmesg output: [47128.000051] ata3: lost interrupt (Status 0x50) [47128.000097] end_request: I/O error, dev sda, sector 58588863 [47128.000134] md: super_written gets error=-5, uptodate=0 [48043.976054] ata3: lost interrupt (Status 0x50) [48043.976086] ata3.00: exception Emask 0x0 SAct 0x0 SErr 0x0 action 0x6 frozen [48043.976132] ata3.00: cmd c8/00:18:bf:40:52/00:00:00:00:00/e1 tag 0 dma 12288 in [48043.976135] res 40/00:00:00:4f:c2/00:00:00:00:00/00 Emask 0x4 (timeout) [48043.976208] ata3.00: status: { DRDY } [48043.976241] ata3: soft resetting link [48044.148446] ata3.00: configured for UDMA/133 [48044.148457] ata3.00: device reported invalid CHS sector 0 [48044.148477] ata3: EH complete Recap: No possibility of overheating 6 drives have failed, 4 of those have been brand new. I'm not sure now that the original two have been faulty, or suffered the same thing that the new ones. There is nothing common in the system, apart from the OS which is Ubuntu Karmic now (started with Jaunty). New MB, new CPU, new RAM, new SATA cables. No, the little holes on the HDD are not covered I'm crying. Really. I don't have the face to return to the store now, it's not possible for 4 drives to fail under 4 months. A few ideas that I have been thinking: Is it possible that I fuck up something when I partition and resync the drives? Can it be so bad that it physicaly wrecks the drive? (since the vendor supplied tool says that the drive is damaged) I do the partitoning with fdisk, and use the same block size for the raid1 partitions (I check the exact block sizes with fdisk -lu) Is it possible that the linux kernel or mdadm, or something is not compatible with this exact brand of HDDs, and thrashes them? Is it possible that it may be the shoebox? Try placing it somewhere else? It's under a shelf now, so humidity is not a problem either. Is it possible that a normal PC case will solve my problem (I'm going to shoot myself then)? I will get a picture tomorrow. Am I just simply cursed? Any help or speculation is greatly appreciated. Edit: The power strip is guarded against overvoltage. Edit2: I have moved inbetween these 4 months, so the possibility of the cause being "dirty" electricity in both places, is very low. Edit3: I have checked the voltages in the BIOS (couldn't borrow a multimeter), and they are all seem correct, the biggest discrepancy is in the 12V, because it's supplying 11.3. Should I be worried about that? Edit4: I put my desktop PC's PSU into the server. The BIOS reported much more accurate voltage readings, and also it has successfully rebuilt the raid1 array, which took some 3-4 hours, so I feel a little positive now. Will get a new PSU tomorrow to test with that. Also, attaching the picture about the box: (disregard the 3rd drive)

    Read the article

  • Multihomed Windows server and DNS resolution

    - by mpkilroy
    I have a Windows 2008 server with two IP addresses assigned to a single NIC. The DNS settings are setup to register the connections's addresses on the DNS server. nslookup shows both IP addresses for the server name. How is name resolution done in this case, i.e. which IP address does the DNS server return for a host lookup? Or does it return both, and the client selects one of the addresses?

    Read the article

  • HP UX can not boot from Ignite Tape

    - by Spirit
    We have hp rp2470 server running hp-ux 11.00, with LVM mirroring. As for redundancy we have second rp2470 same hw (same two processors, same ram, same two hdd’s, same number of lan cards). I want to clone first one to the second. For that purpose I am making ignite tape with the following command: make_tape_recovery -x inc_entire=vg00 Ignite tape finishes without problems. When I boot second server from this ignate tape, server is starting to boot, and ignite restore finishes without any errors, only few notes, which are normal. However vmunix is not booting and when restore finishes, it boot to ISL prompt. From this I cannot boot /stand/vmunix. I tried to run recovery shell but no success. When recovery shell ask to do frecover to restore critical files, then I receive error: frecover(5405): unable to open /dev/rmt/0m At first I thought that the problem might be in the difference of the firmware version of the servers: fw version of production server is: Firmware Version 43.50 and fw version of backup server is: Firmware Version 42.19 So i did a fw upgrade of my backup server so that both servers are v43.50, and tried a recovery but again cant boot the system. Next I did another archive tape with -I (Interactive) flag: make_tape_recovery -I -x inc_entire=vg00 and tried recovery with it, again no good. I cannot find any error or warnings on ignite log, and I cannot boot hpux. I am only on ISL prompt. This is what i've noticed on the gsp logs: ************* SYSTEM ALERT ************** SYSTEM NAME: mcnfwim1 DATE: 07/27/2003 TIME: 10:18:49 ALERT LEVEL: 6 = Boot possible, pending failure - action required REASON FOR ALERT SOURCE: 8 = I/O SOURCE DETAIL: 6 = disk SOURCE ID: 0 PROBLEM DETAIL: 0 = no problem detail LEDs: RUN ATTENTION FAULT REMOTE POWER FLASH OFF ON ON ON LED State: Boot Failed. Running non-OS code. Check Chassis and Console Logs for error messages. 0x00000060860010B0 00000000 00000000 - type 0 = Data Field Unused 0x58000860860010B0 00006706 1B0A1231 - type 11 = Timestamp 07/27/2003 10:18:49 And another gsp log: Log Entry # 3 : SYSTEM NAME: mcnfwim1 DATE: 07/27/2003 TIME: 10:12:20 ALERT LEVEL: 6 = Boot possible, pending failure - action required SOURCE: 8 = I/O SOURCE DETAIL: 6 = disk SOURCE ID: 0 PROBLEM DETAIL: 0 = no problem detail CALLER ACTIVITY: 1 = test STATUS: 0 CALLER SUBACTIVITY: 0B = implementation dependent REPORTING ENTITY TYPE: 0 = system firmware REPORTING ENTITY ID: 00 0x00000060860010B0 00000000 00000000 type 0 = Data Field Unused 0x58000860860010B0 00006706 1B0A0C14 type 11 = Timestamp 07/27/2003 10:12:20 Type CR for next entry, - CR for previous entry, Q CR to quit. Please note that I can not change anything on the production server. I can only make changes to the backup server. Any help is appreciated.

    Read the article

  • WMI query to check setting "Reversible Encryption" in Windows XP

    - by Mart
    In Windows XP, there are two settings in Group Policy I'm looking at: Password must meet complexity requirements Store password using reversible encryption Both of these settings are under Local Computer Policy/Computer Config/Windows Settings/Security Settings/Account Policies/Password Policy. For the first one, I have found the setting in RSOP_SecurityEventLogSettingBoolean class in WMI. However, I can't find the latter. Does anybody know in which class in WMI can I read that particular setting?

    Read the article

  • Clarification on Hyper-V licensing, features, and version

    - by gravyface
    As I understand it, you can do: Windows 2008 + Hyper-V role Windows Hyper-V Server (which is free I believe) Windows 2008 Core + Hyper-V Role I'm assuming that Core + Hyper-V and Hyper-V Server have the smallest footprint, and therefore better performing, less patching, etc. What other trade-offs/compromises would there be compared to the full Windows + Hyper-V role? However, I've read somewhere that Enterprise comes with four Enterprise 2008 (4) guest VM licenses (I think Standard gives you two (2)). Can someone clarify these statements?

    Read the article

  • kvm and qemu host: Is there a limit for max CPUs (Ubuntu 10.04)?

    - by Valentin
    Today we encountered a really strange behaviour on two identical kvm and qemu hosts. The host systems each have 4 x 10 Cores, which means that 40 physical cores are displayed as 80 within the operating system (Ubuntu Linux 10.04 64 Bit). We started a Windows 2003 32 Bit VM (1 CPU, 1 GB RAM, we changed those values multiple times) on one of the nodes and noticed that it took 15 minutes until the boot process began. During those 15 minutes, a black screen is shown and nothing happens. libvirt and the host system show that the qemu-kvm process for the guest is almost idling. stracing this process only shows some FUTEX entries, but nothing special. After those 15 minutes, the Windows VM suddenly starts booting and the Windows logo occurs. After a few seconds, the VM is ready to be used. The VM itself is very performant, so this is no performance issue. We tried to pin the CPUs with the virsh and taskset tools, but this only made things worse. When we boot the Windows VM with a Linux Live CD there is also a black screen for several minutes, but not as long as 15. When booting another VM on this host (Ubuntu 10.04) it also has the black screen problem, and also here the black screen is only shown for 2-3 minutes (instead of 15). So, summerinzing this: Each guest on each of those identical nodes suffers from idling a few minutes after being started. After a few minutes, the boot process suddenly starts. We have observed that the idling time happens right after the bios of the guest was initialized. One of our employees had the idea to limit the amount of CPUs with maxcpus=40 (because of 40 physical cores existing) within Grub (kernel parameter) and suddenly the "black-screen-idling"-behaviour disappeared. Searching the KVM and Qemu mailing lists, the internet, forums, serverfault and other various sites for known bugs etc. showed no useful results. Even asking in the dev IRC channels brought no new ideas. The people there recommend us to use CPU pinning, but as stated before it didn't help. My question is now: Is there a sort of limit of CPUs for a qemu or kvm host system? Browsing the source code of those two tools showed that KVM would send a warning if your host has more than 255 CPUs. But we are not even scratching on that limit. Some stuff about the host system: 3.0.0-20-server kvm 1:84+dfsg-0ubuntu16+0.14.0+noroms+0ubuntu4 kvm-pxe 5.4.4-7ubuntu2 qemu-kvm 0.14.0+noroms-0ubuntu4 qemu-common 0.14.0+noroms-0ubuntu4 libvirt 0.8.8-1ubuntu6 4 x Intel(R) Xeon(R) CPU E7-4870 @ 2.40GHz, 10 Cores

    Read the article

  • Motherboard Is A MCP61PM-HM Rev 1.OB

    - by Dennis Smith
    I have a compaq presario pc SR5110NX The Processor is AMD Athlon 64 Proceessor3800+ It has 512 mb of Ram and a 40gb Hard Drive Here is my problem I Have 2 Sata One Is Black and the other Is White I have 2 red little cables and they have the letters and numbers on them It Is HP P/N:5188-2897 0720 on the side of the cable.Here is the Mother Board MCP61PM-HM Rev 1.0B I need to now where do the two Sata Connectors Connect Too Please Help Thank You So Much.Ps I am running windows XP Pro