  • How can I find the USB wireless adapter into the dmesg log file?

    - by AndreaNobili
    I am pretty new in Linux (RaspBian for RaspBerry Pi but I think that there are not difference) and I have to install an USB wireless network adapter (the product is the TP-Link TL-WN725N, this one: http://www.tp-link.it/products/details/?model=TL-WN725N ) Now, I think that this is not automatically recognized by my system because if I execute ifconfig command I obtain the following output: pi@raspberrypi ~ $ ifconfig eth0 Link encap:Ethernet HWaddr b8:27:eb:2a:9f:b0 inet addr:192.168.1.8 Bcast:192.168.1.255 Mask:255.255.255.0 UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:475 errors:0 dropped:0 overruns:0 frame:0 TX packets:424 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:34195 (33.3 KiB) TX bytes:89578 (87.4 KiB) lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 UP LOOPBACK RUNNING MTU:65536 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:0 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:0 (0.0 B) TX bytes:0 (0.0 B) So now it see only my ethernet network interface and not the wireless. So I was thinkig to try to see into the dmesg, but I don't know what have I to see and how to select it into the dmesg output. For example by the following command I can see the line of the dmesg log file relate to my ethernet port: pi@raspberrypi ~ $ cat /var/log/dmesg |grep -i eth [ 3.177620] smsc95xx 1-1.1:1.0 eth0: register 'smsc95xx' at usb-bcm2708_usb-1.1, smsc95xx USB 2.0 Ethernet, b8:27:eb:2a:9f:b0 [ 18.030389] smsc95xx 1-1.1:1.0 eth0: hardware isn't capable of remote wakeup [ 19.642167] smsc95xx 1-1.1:1.0 eth0: link up, 100Mbps, full-duplex, lpa 0x45E1 But what can I try to search for the USB wireless adapter? Tnx

    Read the article

  • Very uneven CPU utilization with SQL Server 2012 on 2 processor computer with 16 cores / processor

    - by cooplarsh
    After installing SQL Server Enterprise 2012 with the Server + Cal license model, on a computer with 2 processors each with 16 cores (and no hyperthreading involved) and putting the server under extremely heavy load the 16 cores on the first processor were very underutilized, the first 4 cores on the 2nd CPU were heavily utilized, and the last 12 cores were not used at all (because of the 20 core limit for this sql server version). Total CPU utilization was displaying as around 25%. Unfortunately, the server suffered from extremely poor performance even though if the tasks were evenly distributed across the 20 cores it wouldn't have been anywhere near as bad. The Windows Server was running on a VMWare virtual image under ESX Server, but all of the CPU was allocated to the windows server. We tried changing affinity settings (e.g., allocating most cores to CPU and the others to I/O), but that didn't help solve the performance problems. Upgrading the product edition to SQL Server Enterprise Core 2012 not only allowed the SQL Server to utilize the 12 previously unused cores on the 2nd processor, but it also resulted in a much more even distribution of tasks across all of the processors. To get through the backlog of requests cpU utilization jumped to around 90%, and then came down to around 33% once it was caught up, but performance improved dramatically since we failed over to the newly updated version And the performance issues went away. I was wondering if anyone knows what might cause SQL Server to unevenly distribute the load, relying almost exclusively on the first 4 cores of the 2nd processor that had 12 cores idle, and allocate only a few tasks to each of the 16 cores on the first processor. Also, is there any way we could have more evenly distributed the load across the 20 cores that were being used without the product edition upgrade? The flip side of that question is what did the product upgrade do that caused SQL Server to start evenly distributing the load across all of the cores that it recognized? Thanks to any insight to answer these questions and/or links that might help me better understand how to make sense of what was happenings.

    Read the article

  • The RTL8111/8168B NIC under Linux and the r8168 driver

    - by nik
    So I've got one of the infamous R8168 Realtek ethernet NIC, which have some problems under Linux. After some research, I found out I had to use the r8168 driver for this card (and not the r8169 which still loads when nothing else is available), which I did. So now everything works fine... Sort of. My download and upload rates are more than halved compared to what I should get. When I test (with eg. speedtest) I get something like 20M (often 15M) in download and 30M in upload, but if I test under Windows (everything is otherwise identical: same ethernet cable, same connection, at the same time of the day (well 5 min apart)...), I get 50M upload/download (which is what I expect). Where can it come from? Here's some info: ~ # lspci [...] 06:00.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL8111/8168B PCI Express Gigabit Ethernet controller (rev 06) ~ # modinfo r8168 filename: /lib/modules/3.2.1-gentoo-r2/net/r8168.ko version: 8.027.00-NAPI license: GPL description: RealTek RTL-8168 Gigabit Ethernet driver author: Realtek and the Linux r8168 crew <[email protected]> srcversion: 0A6E9F1D4E8E51DE4B6BEE3 alias: pci:v00001186d00004300sv00001186sd00004B10bc*sc*i* alias: pci:v000010ECd00008168sv*sd*bc*sc*i* depends: vermagic: 3.2.1-gentoo-r2 SMP mod_unload [...] ~ # mii-tool -v eth0: negotiated 100baseTx-HD, link ok product info: vendor 00:07:32, model 17 rev 4 basic mode: autonegotiation enabled basic status: autonegotiation complete, link ok capabilities: 100baseTx-FD 100baseTx-HD 10baseT-FD 10baseT-HD advertising: 100baseTx-HD 10baseT-FD 10baseT-HD flow-control link partner: 100baseTx-FD 100baseTx-HD 10baseT-FD 10baseT-HD

    Read the article

  • Connecting XRAID to Sunfire via LSI FC card - Drives not showing up

    - by Matthew Watson
    Hi, I've got a Sunfire T1000 machine ( Solaris 10 10/09 s10s_u8wos_08a SPARC ) with a LSI7404EP-LC fibre channel card in it. This is plugged into an XRAID. The system seems to have picked up the card > /usr/platform/`uname -i `/sbin/prtdiag IO Location Type Slot Path Name Model ----------- ----- ---- --------------------------------------------- ------------------------- --------- MB/PCIE0 PCIE 0 /pci@780/fibre-channel fibre-channel MB/PCIE0 PCIE 0 /pci@780/fibre-channel fibre-channel MB/NET0 PCIE MB /pci@7c0/pci@0/network@4 network-pci14e4,1668 MB/NET1 PCIE MB /pci@7c0/pci@0/network@4,1 network-pci14e4,1668 MB/NET2 PCIX MB /pci@7c0/pci@0/pci@8/network@1 network-pci108e,1648 MB/NET3 PCIX MB /pci@7c0/pci@0/pci@8/network@1,1 network-pci108e,1648 MB/PCIX PCIX MB /pci@7c0/pci@0/pci@8/scsi@2 scsi-pci1000,50 LSI,1064 However it doesn't seem to be able to see the xraid attached to it, lsiutil only reports the onboard SAS controller. > /usr/local/bin/lsiutil ~ LSI Logic MPT Configuration Utility, Version 1.62, January 14, 2009 1 MPT Port found Port Name Chip Vendor/Type/Rev MPT Rev Firmware Rev IOC 1. mpt0 LSI Logic SAS1064 A3 105 010a0000 0 Select a device: [1-1 or 0 to quit] I've tried adding the configuration to /kernal/drv/sd.conf and /kernal/drv/ssd.conf as per this thread, however format still cannot see any drives on the xraid. I'm not sure where to go next. Any suggestions? From what I've read..this should pretty much just eb plug it in and they show up in format..

    Read the article

  • Dell PERC 5 - RAID-10 keeps rebuilding drive 2 every day

    - by raid question
    I have a Dell PowerEdge 2950 with this card: RAID bus controller [0104]: Dell PowerEdge Expandable RAID controller 5 [1028:0015] and six disks in a RAID-10. I replaced drive 2, because it didn't show up, and then it started to rebuild itself: root@backup01:~# megaraidsas-status -- Arrays informations -- -- ID | Type | Size | Status a0d0 | RAID 10 | 5587GiB | DEGRADED -- Disks informations -- ID | Model | Status | Warnings a0e8s0 | ATA ST2000DM001-9YN1 1863GiB | online | errs: media:0 other:5393 a0e8s1 | ATA ST2000DM001-9YN1 1863GiB | online | errs: media:0 other:5394 a0e8s2 | ATA ST2000DM001-1E61 1863GiB | rebuild | errs: media:0 other:99 a0e8s3 | ATA ST2000DM001-9YN1 1863GiB | online | errs: media:0 other:5393 a0e8s4 | ATA ST2000DM001-9YN1 1863GiB | online | errs: media:0 other:5393 a0e8s5 | ATA ST2000DM001-9YN1 1863GiB | online | errs: media:0 other:5393 The rebuild finishes, then the virtual drive becomes optimal, and drive 2 goes online. Then once a day, drive 2 acts like it's been removed, and the rebuild starts all over again. How do I make this once a day rebuild stop? Event Description: Removed: PD 02(e1/s2) Event Description: Removed: PD 02(e1/s2) Info: enclPd=08, scsiType=0, portMap=04, sasAddr=1221000002000000,0000000000000000 Event Description: State change on VD 00/0 from OPTIMAL(3) to DEGRADED(2) Event Description: VD 00/0 is now DEGRADED1 Event Description: State change on PD 02(e1/s2) from ONLINE(18) to FAILED(11) Event Description: State change on PD 02(e1/s2) from FAILED(11) to UNCONFIGURED_BAD(1) Event Description: Background Initialization failed on VD 00/0 Event Description: Inserted: PD 02(e1/s2) Event Description: Inserted: PD 02(e1/s2) Info: enclPd=08, scsiType=0, portMap=04, sasAddr=1221000002000000,0000000000000000 Event Description: PD 02(e1/s2) is not a certified drive Event Description: State change on PD 02(e1/s2) Event Description: State change on PD 02(e1/s2) from UNCONFIGURED_GOOD(0) to OFFLINE(10) from UNCONFIGURED_BAD(1) to UNCONFIGURED_GOOD(0) Event Description: Rebuild automatically started on PD 02(e1/s2) Event Description: State change on PD 02(e1/s2) from OFFLINE(10) to REBUILD(14)

    Read the article

  • Suggestions for Windows 8 migration [closed]

    - by Big Endian
    I'm thinking of migrating to Windows 8. At first I hated it, but I'm pretty sure the Windows 8 model is the future, and I don't particularly want to end up hating the future like my parents, frustrated and bewildered by anything past Windows XP. I'm currently running Windows 7 and my system has been accumulating some problems. It's probably an accumulation of issues from installing too much software, changing firewall settings, installing Ubuntu alongside Windows, and... well I'm not sure, but my computer has been buggy in unexpected ways lately (freezing and unfreezing, display driver crashing and recovering, and what I call "deep freeze/thaw cycle" where the mouse won't even move for a while). I'm good at solving computer problems, but I can't seem to get to the root of these and my best idea for fixing them is making sure I've backed up every file then re-installing the entire OS. Luckily for me, a new OS is just around the corner so this would be a good time to get two things out of the way at once. The problem I see is that the upgrade options I see are all "seamless". I don't want a seamless upgrade. I want to wipe the slate clean and start all over. Does this mean I will have to buy a full, new copy of Windows 8 rather than one of the cheaper upgrading options? Or does it not make since for me to go to Windows 8 given that I have a laptop, not a tablet? Maybe I should just re-install Windows 7, or even call good enough good enough, try to eliminate the bugs, and start with a fresh slate in 2-3 years after this computer eventually dies entirely from (inevitable) hardware failure. What would be the advantages or disadvantages and costs of each option, how would I go about upgrading to Windows 8 if that's the option I choose, and what is your personal opinion about my situation?

    Read the article

  • apache2 mysql authentication module and SHA1 encryption

    - by Luca Rossi
    I found myself in a setup on where I need to enable some authentication method using mysql. I already have an user scheme. That user scheme is working like a charm with MD5 password and CRYPT, but when I turn to SHA1sum it says: [Fri Oct 26 00:03:20 2012] [error] Unsupported encryption type: Sha1sum No useful debug informations on log files. This is my setup and some info: debian6 apache and ssl installed packages: root@sistemichiocciola:/etc/apache2/mods-available# dpkg --list | grep apache ii apache2 2.2.16-6+squeeze8 Apache HTTP Server metapackage ii apache2-mpm-prefork 2.2.16-6+squeeze8 Apache HTTP Server - traditional non-threaded model ii apache2-utils 2.2.16-6+squeeze8 utility programs for webservers ii apache2.2-bin 2.2.16-6+squeeze8 Apache HTTP Server common binary files ii apache2.2-common 2.2.16-6+squeeze8 Apache HTTP Server common files ii libapache2-mod-auth-mysql 4.3.9-13+b1 Apache 2 module for MySQL authentication ii libapache2-mod-php5 5.3.3-7+squeeze14 server-side, HTML-embedded scripting language (Apache 2 module) root@sistemichiocciola:/etc/apache2/sites-enabled# dpkg --list | grep ssl ii libssl-dev 0.9.8o-4squeeze13 SSL development libraries, header files and documentation ii libssl0.9.8 0.9.8o-4squeeze13 SSL shared libraries ii openssl 0.9.8o-4squeeze13 Secure Socket Layer (SSL) binary and related cryptographic tools ii openssl-blacklist 0.5-2 list of blacklisted OpenSSL RSA keys ii ssl-cert 1.0.28 simple debconf wrapper for OpenSSL my vhost setup: AuthMySQL On Auth_MySQL_Host localhost Auth_MySQL_User XXX Auth_MySQL_Password YYY Auth_MySQL_DB users AuthName "Sistemi Chiocciola Sezione Informatica" AuthType Basic # require valid-user require group informatica Auth_MySQL_Encryption_Types Crypt Sha1sum AuthBasicAuthoritative Off AuthUserFile /dev/null Auth_MySQL_Password_Table users Auth_MYSQL_username_field email Auth_MYSQL_password_field password AuthMySQL_Empty_Passwords Off AuthMySQL_Group_Table http_groups Auth_MySQL_Group_Field user_group Have I missed a package/configuration or something?

    Read the article

  • Broken fonts in Konsole KDE 4.3.4

    - by depesz
    I have a strange situation - after some upgrades a couple of days ago fonts in KDE Konsole broke. To make it more specific - standard fonts look more or less OK, but when I use my national characters (like acelnsózz) they all look broken - like from another font, or badly scaled. The same problem doesn't exist in GNOME Terminal. I usually use the Terminus font, so I used this for demonstration, but it shows in other fonts as well - if that will be necessary I will provide list. Konsole shot: GNOME Terminal shot: As for my settings: =$ cat /etc/X11/xorg.conf Section "Device" Identifier "Builtin Default intel Device 0" Driver "intel" EndSection Section "Monitor" Identifier "Monitor0" VendorName "Monitor Vendor" ModelName "Monitor Model" EndSection Section "Screen" Identifier "Builtin Default intel Screen 0" Device "Builtin Default intel Device 0" Monitor "Monitor0" EndSection Section "InputDevice" Identifier "touchpad" Driver "synaptics" Option "CorePointer" EndSection Section "ServerLayout" Identifier "Builtin Default Layout" Screen "Builtin Default intel Screen 0" InputDevice "touchpad" EndSection =$ xdpyinfo | grep -E resolution\|dimensions dimensions: 1680x1050 pixels (444x277 millimeters) resolution: 96x96 dots per inch I tried forcing DPI in system settings (to 120), or adding monitor size to xorg.conf - so far nothing helped. Any idea on what should I do to make it work sanely again?

    Read the article

  • Broken fonts in konsole kde 4.3.4

    - by depesz
    I have strange situation - after some upgrade couple of days ago fonts in KDE konsole broke. To make it more specific - standard fonts look more or less ok, but when I use my national characters (like acelnsózz) they all look broken - like from another font, or badly scaled. The same problem doesn't exist in gnome-terminal. I usually use Terminus font, so I used this for demonstration, but it shows in other fonts as well - if that will be necessary I will provide list. Konsole shot: gnome-terminal shot: As for my settings: =$ cat /etc/X11/xorg.conf Section "Device" Identifier "Builtin Default intel Device 0" Driver "intel" EndSection Section "Monitor" Identifier "Monitor0" VendorName "Monitor Vendor" ModelName "Monitor Model" EndSection Section "Screen" Identifier "Builtin Default intel Screen 0" Device "Builtin Default intel Device 0" Monitor "Monitor0" EndSection Section "InputDevice" Identifier "touchpad" Driver "synaptics" Option "CorePointer" EndSection Section "ServerLayout" Identifier "Builtin Default Layout" Screen "Builtin Default intel Screen 0" InputDevice "touchpad" EndSection =$ xdpyinfo | grep -E resolution\|dimensions dimensions: 1680x1050 pixels (444x277 millimeters) resolution: 96x96 dots per inch I tried forcing DPI in system settings (to 120), or adding monitor size to xorg.conf - so far nothing helped. Any idea on what should I do to make it work sanely again?

    Read the article

  • Internet Connection not working - USB LAN connection - from particular modem

    - by Paul
    I am trying to fix Internet connection on a friends Dell inspiron 1720 with XP service pack 3. It has an integrated network card that stopped working, after powering down/up the modem still didnt work I brought it back to my place to try a few things ie check cable, update driver etc... still didnt work. So I bought a USB LAN connector. It didnt work straight away but I went to configure the properties and changed the ConnectionType from AutoSense to 100 BaseT 10BaseT Full_Duplex, I basically just tried them all. From my place when connected to my desktop - 10 BaseT and 10BaseT Full_Duplex worked. From my place When connected to their laptop - 10 BaseT and 10BaseT Full_Duplex worked. Happy I went back to my friends house confident it would all work, and it didnt. Brought it back to mine and it did. While there, in Network Connections the connection is there recognized, enabled, 'working properly' it just says not connected. Also there is no led on the USB connector While at mine as above except there is an led on the USB connector and it says connected. Other difference I can think of is they have a cable modem, I'm plugged into the back of a Belkin wireless router - would this make a difference? Any other ideas what to try? (Would getting the model of the cable modem help anyone?) The USB connector is "DM9601 USB to Fast Ethernet"

    Read the article

  • Adding a Second Wireless Router to an Existing Wired Network

    - by KVCrawford
    I apologize ahead of time, I know this has been asked before, but I'm still having problems...maybe you guys can help. I started out with the basic instructions from the highest-voted answer at http://serverfault.com/questions/41572/adding-a-second-wireless-router-to-my-network The new Wireless router in question is a Linksys Wireless-N Gigabit Router, Model # WRT310N Here are the steps I've taken in setting it up: Plug my laptop into LAN port #2 in the new router. Nothing else is connected at this point Configure the new router to be 192.168.1.200 (the original router is 192.168.1.1, and its DHCP clients are from 192.168.1.100-x.x.x.199) Set the internet connection on the new router to "DHCP Client" Turn off the DHCP server & NAT routing on the new router Plug in a LAN cable from the original router into the LAN port #1 on the new router (NOT the WAN port, nothing is plugged in there) Reset the new router Afterwards, I try to ping 192.168.1.1 from the laptop plugged into LAN port #2 on the new router, with no response. 192.168.1.200 garners no response either. Typing "ipconfig" tells me: Autoconfiguration IP Address: 169.254.198.113 Subnet Mask: 255.255.0.0 Default Gateway: 169.254.198.113 What's going wrong? I appreciate any help!

    Read the article

  • Throughput; capacity planning help for C10K like design

    - by z8000
    I am designing a network service in which clients connect and stay connected -- the model is not far off from IRC less the s2s connections. I could use some help understanding how to do capacity planning, in particular with the system resource costs associated with handling messages from/to clients. There's an article that tried to get 1 million clients connected to the same server [1]. Of course, most of these clients were completely idle in the test. If the clients sent a message every 5 seconds or so the system would surely be brought to its knees. But... How do you do less hand-waving and you know, measure such a breaking point? We're talking about messages being sent by a client over a TCP socket, into the kernel, and read by an application. The data is shuffled around in memory from one buffer to another. Do I need to consider memory throughput ("5 GT/s" [2], etc.)? I'm pretty sure I have the ability to measure the basic memory requirements due to TCP/IP buffers, expected bandwidth, and CPU resources required to process messages. I'm a little dim on what I'm calling "thoughput". Help! Also, does anyone really do this? Or, do most people sort of hand-wave and see what the real world offers, and then react appropriately? [1] http://www.metabrew.com/article/a-million-user-comet-application-with-mochiweb-part-3/ [2] http://en.wikipedia.org/wiki/GT/s

    Read the article

  • Macs don't connect to wifi access point but PCs will

    - by Josh
    So, as a side project I'm going to try and figure out why the wifi APs in my building exhibit the following behavior: - They typically allow all types of computers to connect without issues - Sometimes Apples can't get an IP address but will still connect to the AP's signal - Less often, PCs can't connect to the wifi (same as above - yes signal, no IP addy) - Don't let Raiders fans on no matter the time of day! My first thought was that the DHCP leases were all taken up when the Apples would try to connect, and it was just their unlucky timing, but I would then try to log on with a PC that had a new, unleased MAC address and it would work... Could this be something to do with interoperability between an apple wifi card, and the APs? Different parts of the DHCP lease being taken up first? The fact that the Seattle Mariners might actually be good this year?? If this hasn't used up everyone's patience (with my crappy sports jokes), something else I could use some help with: - We don't have the model or type of AP - This is because there is no documentation available for them, and they literally look like small white boxes with no writing on them. Also, the company that installed them is out of business, so the situation might be that no docs will ever be on the way. -- Do you guys have any ideas on how to figure out what we have? Thanks as always for all the help, and I'm looking forward to the day when I know enough to start contributing back to the site, Josh

    Read the article

  • Slow File Copy observed copying 40GB files across network to iSCSI device

    - by Rick
    Here's a curious ones for the gurus: Setup: Source Machine: Windows Server 2003 R2 machine with local hard drive. VHD file of 40GB. 1 x 1Gbps network card, Cat6 cable, switch. Target Machine: Windows Server 2008 R2 machine with iSCSI connection to iSCSI target on separate machine (1TB, RAID5). 1 x 1Gbps network card, Cat6 cable, connected to same switch as for Source Machine. Second 1Gbps network card, Cat6 cable, connected via isolated switch to the iSCSI target. Switches are Netgear JGS524 model (web managed). If I copy from the Win2003R2 machine to Win2008R2 machine local drive I get 40GB in 45 minutes, 36 seconds. If I copy from the Win2008R2 machine to the iSCSI target (local drive to iSCSI target) I get 40GB in 37 minutes 56 seconds. If I copy from the Win2003R2 machine to the iSCSI target via the Win2008R2 machine I get 40GB in 3 hours, 50 minutes, 24 seconds. All copies were done via the following command issued on the Win2008R2 box: XCOPY <source> <target> /J XCOPY /J - Copies using unbuffered I/O. Recommended for very large files. So, what's the bit I'm missing here? Why does a back-to-back copy take in total 1 hour, 23 minutes, 32 seconds when a "straight through" copy take almost 3 times as long? Switches show no errors, network hovers around the 3% utilisation mark for the duration of the copy (whereas the "back-to-back" copies are around the 25% utilisation mark). What have I missed?

    Read the article

  • Lenovo S110 netbook screen resolution Ubuntu

    - by Neigyl R. Noval
    I am still stuck with 800x600 resolution. Here is the output of lspci: 00:00.0 Host bridge: Intel Corporation Device 0bf2 (rev 03) 00:02.0 VGA compatible controller: Intel Corporation Device 0be2 (rev 09) 00:1b.0 Audio device: Intel Corporation N10/ICH 7 Family High Definition Audio Controller (rev 02) 00:1c.0 PCI bridge: Intel Corporation N10/ICH 7 Family PCI Express Port 1 (rev 02) 00:1c.1 PCI bridge: Intel Corporation N10/ICH 7 Family PCI Express Port 2 (rev 02) 00:1c.2 PCI bridge: Intel Corporation N10/ICH 7 Family PCI Express Port 3 (rev 02) 00:1d.0 USB Controller: Intel Corporation N10/ICH7 Family USB UHCI Controller #1 (rev 02) 00:1d.1 USB Controller: Intel Corporation N10/ICH 7 Family USB UHCI Controller #2 (rev 02) 00:1d.2 USB Controller: Intel Corporation N10/ICH 7 Family USB UHCI Controller #3 (rev 02) 00:1d.3 USB Controller: Intel Corporation N10/ICH 7 Family USB UHCI Controller #4 (rev 02) 00:1d.7 USB Controller: Intel Corporation N10/ICH 7 Family USB2 EHCI Controller (rev 02) 00:1e.0 PCI bridge: Intel Corporation 82801 Mobile PCI Bridge (rev e2) 00:1f.0 ISA bridge: Intel Corporation NM10 Family LPC Controller (rev 02) 00:1f.2 SATA controller: Intel Corporation N10/ICH7 Family SATA AHCI Controller (rev 02) 00:1f.3 SMBus: Intel Corporation N10/ICH 7 Family SMBus Controller (rev 02) 01:00.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL8101E/RTL8102E PCI Express Fast Ethernet controller (rev 05) 02:00.0 Network controller: Realtek Semiconductor Co., Ltd. Device 8176 (rev 01) Also, I tried modifying /usr/lib/X11/xorg.conf.d/10-monitor.conf to fix this problem, but still does not work: Section "Monitor" Identifier "Monitor0" VendorName "Monitor Vendor" ModelName "Monitor Model" EndSection Section "Screen" Identifier "Screen0" Monitor "Monitor0" Device "Card0" SubSection "Display" Viewport 0 0 Depth 1 Modes "1024x768" EndSubSection SubSection "Display" Viewport 0 0 Depth 4 Modes "1024x768" EndSubSection SubSection "Display" Viewport 0 0 Depth 8 Modes "1024x768" EndSubSection SubSection "Display" Viewport 0 0 Depth 15 Modes "1024x768" EndSubSection SubSection "Display" Viewport 0 0 Depth 16 Modes "1024x768" EndSubSection SubSection "Display" Viewport 0 0 Depth 24 Modes "1024x768" EndSubSection EndSection Section "Device" Identifier "Card0" Driver "vesa" VendorName "Intel Corporation Device" EndSection I'm using Gnome. System Preference Monitor screen resolution sticks to 800x600. What am I going to do?

    Read the article

  • linux hardware raid 10 / lvm / virtual machine partition alignment and filesystem optimization

    - by Jason Ward
    I've been reading everything I can find about partition alignment and filesystem optimization (ext4 and xfs) but still don't know enough to be confident in setting up my current configuration. My remaining confusion comes from the LVM layer and if I should use raid parameters on the filesystem in guest os'es. My main questions are: When I use 'pvcreate --dataalignment' do I use the stripe-width as calculated for a filesystem on RAID (128kB for ext4 in my situation), the Stripe size of the RAID set (256kB), something else altogether, or do I not need this? When I create ext2/3/4 or xfs filesystems in guests on the Logical Volumes, should I add the settings for the underlying RAID (e.g. mkfs.ext4 -b 4096 -E stride=64,stripe-width=128)? Does anyone see any glaring errors in my set up below? I'm running some benchmarks now but haven't done enough to start comparing results. I have four drives in RAID 10 on a 3ware 9750-4i controller (more details on the settings below) giving me a 6.0TB device at /dev/sda. Here is my partition table: Model: LSI 9750-4i DISK (scsi) Disk /dev/sda: 5722024MiB Sector size (logical/physical): 512B/512B Partition Table: gpt Number Start End Size File system Name Flags 1 1.00MiB 257MiB 256MiB ext4 BOOTPART boot 2 257MiB 4353MiB 4096MiB linux-swap(v1) 3 4353MiB 266497MiB 262144MiB ext4 4 266497MiB 4460801MiB 4194304MiB Partition 1 is to be the /boot partition for my xen host. Partition 2 is swap. Partition 3 is to be the root (/) for my xen host. Partition 4 is to be (the only) physical volume to be used by LVM (for those who are counting, I left about 1.2TB unallocated for now) For my Xen guests, I usually create a Logical Volume of the needed size and present it to the guests for them to partition as needed. I know there are other ways of handling that but this method works best for my situation. Here's the hardware of interest on my CentOS 6.3 Xen Host: 4x Seagate Barracuda 3TB ST3000DM001 Drives (sector size: 512 logical/4096 physical) 3ware 9750-4i w/BBU (sector size reported: 512 logical/512 physical) All four drives make up a RAID 10 array. Stripe: 256kB Write Cache enabled Read Cache: intelligent StoreSave: Balance Thanks!

    Read the article

  • Convert a cassette tape recording to digital format

    - by Electric Automation
    Has anyone been successful with transferring audio cassette tape recordings to a digital format? I would like to preserve old cassette tape recordings of my grandparents to some digital format: MP3, WAV, etc... The quality of the tapes are mediocre. I think I can handle the quality restoration but getting the audio from tape to digital is my question. Below is a list of the hardware that I can work with: Cassette Deck: I have a Technics stereo cassette deck model RS-B12. It has separate left and right IN and OUT RCA type jacks on the back. In the front it has a headphone phono jack, plus left and right mic input phono jacks. On the computer side: -I have a Windows Vista PC with no additional software other than what came with the machine from Costco. No sound editing software that I can see. There is no sound card on the PC. On the front panel there is a mini-phono mic input jack and there are several different types of in/out mini-phono jacks on the back. In addition, USB and Firewire. I also have access to a new (2009) iMac with a mini-phono input jack for a powered mic or other audio source and GarageBand that has come with the computer. In addition, USB and Firewire. What are my options for getting these cassette recordings into a digital format? Whats the best format? What sort of wires would I need and will I want to utilize the USB or Firewire or can I simply use the audio inputs on the PC (or Mac) to receive the audio stream?

    Read the article

  • Copy from CDROM is very slow in Ubuntu

    - by ???
    I'm using the command to copy CDROM image: # dd if=/dev/sr0 of=./maverick.iso But it's very slow, at about 350k bytes/sec. I've searched the google, and try the command # hdparm -vi /dev/sr0 /dev/sr0: HDIO_DRIVE_CMD(identify) failed: Bad address IO_support = 1 (32-bit) readonly = 0 (off) readahead = 256 (on) HDIO_GETGEO failed: Inappropriate ioctl for device Model=DVD-ROM UJDA775, FwRev=DA03, SerialNo= Config={ Fixed Removeable DTR<=5Mbs DTR>10Mbs nonMagnetic } RawCHS=0/0/0, TrkSize=0, SectSize=0, ECCbytes=0 BuffType=unknown, BuffSize=unknown, MaxMultSect=0 (maybe): CurCHS=0/0/0, CurSects=0, LBA=yes, LBAsects=0 IORDY=yes, tPIO={min:180,w/IORDY:120}, tDMA={min:120,rec:120} PIO modes: pio0 pio1 pio2 pio3 pio4 DMA modes: sdma0 sdma1 sdma2 mdma0 mdma1 mdma2 UDMA modes: udma0 udma1 *udma2 AdvancedPM=no Drive conforms to: ATA/ATAPI-5 T13 1321D revision 3: ATA/ATAPI-1,2,3,4,5 * signifies the current active mode Seems like DMA is already on. And a device test gives: # hdparm -t /dev/sr0 /dev/sr0: Timing buffered disk reads: 2 MB in 6.58 seconds = 311.10 kB/sec # sudo hdparm -tT /dev/sr0 /dev/sr0: Timing cached reads: 2 MB in 2.69 seconds = 760.96 kB/sec Timing buffered disk reads: m 4 MB in 5.19 seconds = 789.09 kB/sec The CD-ROM device and disc should be okay because I can copy it very fast in Windows, using UltraISO utility. So I guess there is something not configured right in Ubuntu, is it?

    Read the article

  • How to set up multiple SSIDs with bandwidth limiting on a single wireless router?

    - by Rahul Narain
    I have an Asus WL-520GU wireless router connected to a cable modem that I use for wireless internet access in my apartment. I would like to set it up so that it provides two SSIDs: one secured and password-protected for my regular use, and a "guest" SSID that's unsecured but throttled to, say, 10% of the available bandwidth. What is the most straightforward way to do this? I've been looking into DD-WRT and Tomato, both of which support my router. DD-WRT supports setting up multiple SSIDs using the GUI, but I don't know if it's possible to limit the bandwidth of each SSID independently; point #12 in this FAQ thread says it's not possible to limit by day or by MAC address, which is discouraging but not conclusive. Tomato allows bandwidth limits in its QoS settings, going by the screenshot here, but multiple SSID support is still experimental and it doesn't look like it will work with the encryption settings or bandwidth limits in the GUI. I'd like to know a good way to do this which gives me the fewest opportunities for screwing up. I'm no stranger to the command line, if that turns out to be what's necessary, but if so, please explain what the commands are doing because I don't have a good mental model of what needs to happen to set this up.

    Read the article

  • How to fix display on external Samsung Syncmaster shifted to the right when connected to Macbook Pro?

    - by joe larson
    Is there something special I need to do to be able to use external LCD displays with my new MacBook Pro? Do I need extra software, or do I possibly need a different cable? I'm attempting to use an external display with my MBP. I've got a "Mini DisplayPort to VGA Female Adapter for Mac", plugged into the thunderbolt port on my MBP, which I understood should be compatible with thunderbolt. I've tried this with three different SyncMaster models: a B2330 (21.5"), a EX2220 (22"), and a third (also 22" ish) which I don't have the model # for -- but all are 1920x1080 resolution; plus an additional HP monitor of similar size and resolution. In all four cases, the MBP recognizes the screen and choses the correct resolution. However, the display is shifted over about 1 inch. This is true no matter if I change screen resolutions also. The controls on the monitor for horizontal position don't help. Also, sometimes (especially if I drag an app over into the second screen), the screen starts skipping left to right and having bands of fuzz. Additionally, the monitor will periodically blink off for a moment, trying to switch from Digital to Analog and back (the Syncmaster shows text on the screen to tell you it's trying to do this). Often when it comes back from one of these blank-outs, it will show OK (no skipping or fuzz) but still shifted right; then after a few seconds it will go wrong again skipping and fuzzy. This photo shows the worst of it. I've added red rectangles to show the physical edge of the screen, and a yellow rectangle to show the empty space on the left of the screen. (Sorry for the awful quality and lighting!) Also, it's worth noting I am on Mac OS X 10.6.7, and yes I have this update 1.4 installed.

    Read the article

  • Buffer Overflow errors when reading ConfigDelay and Manufacturer info from registry

    - by peter
    Hi All, This is a strange driver error which doesn't make a lot of sense to me. I am running an application developed in C# .NET which our company develops. I was monitoring the application using process monitor and noticed that it accesses the registry a lot. The output on Process Monitor looks like this, Operation Result Path RegQueryValue Success HKLM\System\CurrentControlSet\Enum\SWMUXBUS\SW_MODEM\7&6c4af30&0&5&0004\Driver RegQueryValue Success HKLM\System\CurrentControlSet\Control\Class\{4D36E96D-E325-11CE-BFC1-08002BE10318}\0000\Properties RegQueryValue Success HKLM\System\CurrentControlSet\Control\Class\{4D36E96D-E325-11CE-BFC1-08002BE10318}\0000\Default RegQueryValue Success HKLM\System\CurrentControlSet\Control\Class\{4D36E96D-E325-11CE-BFC1-08002BE10318}\0000\InactivityScale RegQueryValue Name Not Found HKLM\System\CurrentControlSet\Control\Class\{4D36E96D-E325-11CE-BFC1-08002BE10318}\0000\PowerDelay RegQueryValue Name Not Found HKLM\System\CurrentControlSet\Control\Class\{4D36E96D-E325-11CE-BFC1-08002BE10318}\0000\ConfigDelay RegQueryValue Buffer Overflow HKLM\System\CurrentControlSet\Control\Class\{4D36E96D-E325-11CE-BFC1-08002BE10318}\0000\Manufacturer RegQueryValue Buffer Overflow HKLM\System\CurrentControlSet\Control\Class\{4D36E96D-E325-11CE-BFC1-08002BE10318}\0000\Model RegQueryValue Name Not Found HKLM\System\CurrentControlSet\Control\Class\{4D36E96D-E325-11CE-BFC1-08002BE10318}\0000\Version The app is reading this stuff every 5 seconds from the registry, so I would ask a few questions, 1) What is this stuff 2) Why is the app reading this stuff 3) Why is it saying 'Buffer Overflow' 4) Could this cause performance problems for my app? From what I can see the app does not explicitly read this stuff, so I think this relates to a driver on the machine (which is a netbook)

    Read the article

  • Unable to write DVD-R(Blank DVD's)

    - by FrozenKing
    I have a problem in dvd drive i.e. It can read CD/DVD and can write CD and all CD/DVD-RW but cannot write DVD DVD drive model is SH-S203B Samsung; I also have a log file created by nero burning rom 11. Actually the fact is no Blank DVD's are being read in my dvd drive only previously written dvd's can be read! Is this the problem of OS or should I try cleaning the dvd drive or my DVD drive is 4yrs old so is it going to spoil now, since it is showing this type of symptoms! OS = WinXP AV = KIS 2012 DVD Drive = Samsung SH-S203B (Also tried latest firmware and downgrade versions also) IA32 Nero Version: 11.2.4.100 Internal Version: 11,2,4,100 Recorder: <TSSTcorp CDDVDW SH-S203B>Version: SB04 - HA 1 TA 0 - 11.2.4.100 Adapter driver: <Serial ATA> HA 1 Drive buffer : 2048kB Bus Type : via Inquiry data CD-ROM: <TSSTcorp CDDVDW SH-S203B >Version: SB04 - HA 1 TA 0 - 11.2.4.100 Adapter driver: <Serial ATA> HA 1 18:58:10 #37 SPTI -1511 File SCSIPassThrough.cpp, Line 224 CdRom0: SCSIStatus(x02) WinError(0) NeroError(-1511) CDB Data: 0x28 00 00 00 00 00 00 00 10 00 Sense Key: 0x04 (KEY_HARDWARE_ERROR) Sense Code: 0x3E Sense Qual: 0x02 Sense Area: 0x70 00 04 00 00 00 00 0A 00 00 00 00 3E 02 Buffer x08047340: Len x8000 18:58:10 #38 SectorVerify 20 File Cdrdrv.cpp, Line 12057 Read errors from sector 0 to 14 <Padding> 18:58:19 #39 SPTI -1511 File SCSIPassThrough.cpp, Line 224 CdRom0: SCSIStatus(x02) WinError(0) NeroError(-1511) CDB Data: 0x28 00 00 00 00 10 00 00 10 00 Sense Key: 0x04 (KEY_HARDWARE_ERROR) Sense Code: 0x3E Sense Qual: 0x02 Sense Area: 0x70 00 04 00 00 00 00 0A 00 00 00 00 3E 02 Buffer x08047340: Len x8000 18:58:19 #40 SectorVerify 21 File Cdrdrv.cpp, Line 12057 Read error at sector 15 <Virtual Multisession Info> 18:58:19 #41 SectorVerify 20 File Cdrdrv.cpp, Line 12057 Read errors from sector 16 to 18 <Volume Structure Descriptor Sequence> 18:58:28 #42 SPTI -1511 File SCSIPassThrough.cpp, Line 224 CdRom0: SCSIStatus(x02) WinError(0) NeroError(-1511) CDB Data: 0x28 00 00 00 00 20 00 00 10 00 Sense Key: 0x04 (KEY_HARDWARE_ERROR) Sense Code: 0x3E Sense Qual: 0x02 Sense Area: 0x70 00 04 00 00 00 00 0A 00 00 00 00 3E 02 Buffer x08047340: Len x8000

    Read the article

  • What does this mean: "SATP VMW_SATP_LOCAL does not support device configuration"?

    - by Jason Tan
    Can anyone tell me what this means in ESXi 5.1?: SATP VMW_SATP_LOCAL does not support device configuration I've googled it and I get a lot of results, but as yet all the pages that contain the string are discussing other matters. The storage array is a HDS HUS-VM and the hosts are HP b460c G8 blades with flex fabric and flex fabric VCs which I am in the process of commissioning and would like to get it started on the right foot - i.e. error and warning free! naa.600508b1001c56ee3d70da65f071da23 Device Display Name: HP Serial Attached SCSI Disk (naa.600508b1001c56ee3d70da65f071da23) Storage Array Type: VMW_SATP_LOCAL Storage Array Type Device Config: SATP VMW_SATP_LOCAL does not support device configuration. Path Selection Policy: VMW_PSP_FIXED Path Selection Policy Device Config: {preferred=vmhba0:C0:T0:L1;current=vmhba0:C0:T0:L1} Path Selection Policy Device Custom Config: Working Paths: vmhba0:C0:T0:L1 Is Local SAS Device: true Is Boot USB Device: false This is the same LUN: ~ # esxcli storage core device list -d naa.60060e80132757005020275700000016 naa.60060e80132757005020275700000016 Display Name: HITACHI Fibre Channel Disk (naa.60060e80132757005020275700000016) Has Settable Display Name: true Size: 204800 Device Type: Direct-Access Multipath Plugin: NMP Devfs Path: /vmfs/devices/disks/naa.60060e80132757005020275700000016 Vendor: HITACHI Model: OPEN-V Revision: 5001 SCSI Level: 2 Is Pseudo: false Status: degraded Is RDM Capable: true Is Local: false Is Removable: false Is SSD: false Is Offline: false Is Perennially Reserved: false Queue Full Sample Size: 0 Queue Full Threshold: 0 Thin Provisioning Status: unknown Attached Filters: VAAI_FILTER VAAI Status: supported Other UIDs: vml.020001000060060e801327570050202757000000164f50454e2d56 Is Local SAS Device: false Is Boot USB Device: false ~ #

    Read the article

  • Karmic iptables missing kernel moduyles on OpenVZ container

    - by luison
    After an unsuccessful p2v migration of my Ubuntu server to an OpenVZ container which I am stack with I thought I would give a try to a reinstall based on a clean OpenVZ template for Ubuntu 9.10 (from the OpenVZ wiki) When I try to load my iptables rules on the VM machine I've been getting errors which I believe are related to kernel modules not being loaded on the VM from the /vz/XXX.conf template model. I've been testing with a few post I've found but I was stack with the error: WARNING: Deprecated config file /etc/modprobe.conf, all config files belong into /etc/modprobe.d/. FATAL: Could not load /lib/modules/2.6.24-10-pve/modules.dep: No such file or directory iptables-restore v1.4.4: iptables-restore: unable to initialize table 'raw' Error occurred at line: 2 Try `iptables-restore -h' or 'iptables-restore --help' for more information. I read about the template not loading all iptables modules so I added modules to the XXX.conf of the VZ virtual machine like this: IPTABLES="ip_tables iptable_filter iptable_mangle ipt_limit ipt_multiport ipt_tos ipt_TOS ipt_REJECT ipt_TCPMSS ipt_tcpmss ipt_ttl ipt_LOG ipt_length ip_conntrack ip_conntrack_ftp ip_conntrack_irc ipt_conntrack ipt_state ipt_helper iptable_nat ip_nat_ftp ip_nat_irc" As the error remained I read that I should build dependencies again on the virtual machine: depmod -a but this returned an error: WARNING: Couldn't open directory /lib/modules/2.6.24-10-pve: No such file or directory FATAL: Could not open /lib/modules/2.6.24-10-pve/modules.dep.temp for writing: No such file or directory So I read again about creating the directory empty and redoing "depmod -a" it. I now don't get the dependancies error but get this and I don't have a clue how to proceed: WARNING: Deprecated config file /etc/modprobe.conf, all config files belong into /etc/modprobe.d/. FATAL: Module ip_tables not found. iptables-restore v1.4.4: iptables-restore: unable to initialize table 'raw' Error occurred at line: 2 Try `iptables-restore -h' or 'iptables-restore --help' for more information. I understand that iptables rules have to be different on the VM machine and perhaps some of the rules we are trying to apply (from our physical server) are not compatible but these are just source IP and destination port checks that I would like to be able to have available . I've heard that on the CentOS template there are no issues with this, so I understand is to do with VM config. Any help would be greatly appreciated.

    Read the article

  • How to discover true identity of hard disk?

    - by F21
    I have 2 fake external hard drives that claim to have a storage capacity of 2TB. I pulled the enclosure apart and the hard drives seems to be refurbished ones with their labels replaced as Barracuda LP 2000 GB labels (the serial numbers on both labels are the same). Interestingly, one of the drives have 160G written on it with pencil. However, the counterfeiters seem to have done something to the firmware, because CrystalDiskInfo reports them as 2TB ST2000DL003 drives. I then delete the 1.81 TB partition in Windows disk management and tried to create a new one and format it. Once I get to this point, the drives would make some noise that is common to dying drives. I am not interested in using these drives for production, but I am interested in finding the true identity (manufacturer/serial number/model number, etc) and restoring it to their factory defaults with the right capacity. Can this be done without any special equipment? This would be an interesting learning exercise. Some pictures of the drives in question: Here are the screens from CrystalDiskInfo: Note the serial numbers are the same (these are 2 different drives!). How is this done? Did they have to tamper with the controller board? I would assume that changing the firmware doesn't change the serial number at all.

    Read the article