Search Results

Search found 16894 results on 676 pages for 'block device'.

Page 541/676 | < Previous Page | 537 538 539 540 541 542 543 544 545 546 547 548  | Next Page >

  • Xorg input devices fail without udev

    - by Sampo
    What I am trying to do: Launch Xorg server without udev device manager. What I have tried to do: Make sure that /dev/ has all required nodes, such as /dev/input/*. Make sure that all required kernel modules are loaded. Launch Xorg. What happens: Xorg starts up as excepted. Xorg loads correct GPU driver and sets right screen resolution. Xorg blocks all input devices (keyboard, mouse), Alt+F[1-12] does not work (can't go back to tty1). Unraw'ing keyboard to take its control from X removes blocking and after unraw I can Alt+F1 back to tty1. Xorg still does not handle any input. Why I think that it should work: Same configuration works well if udev is loaded. Loading udev does not add or modify /dev/ contents, all nodes stays same. My main question is: How to make Xorg input devices work without udev? Any additional information about how Xorg really uses/detects/grabs keyboard would be helpful. And any additional information about what udev really does (other than populating /dev/) would also be helpful.

    Read the article

  • Disabling Keyboard Wakeup for Ubuntu 10.04 on Acer 1810TZ

    - by sybreon
    My Acer Aspire 1810TZ laptop suspends fine but wakes up on any slight key-press. I would like to disable this behaviour. I read that it involves disabling something in the /proc/acpi/wakeup but SLPB does not seem to be listed at all. root@1810TZ:/etc# cat /proc/acpi/wakeup Device S-state Status Sysfs node UHC0 S3 disabled pci:0000:00:1d.0 UHC1 S3 disabled pci:0000:00:1d.1 UHC2 S3 disabled pci:0000:00:1d.2 UHCR S3 disabled EHC1 S3 disabled pci:0000:00:1d.7 UHC3 S3 disabled pci:0000:00:1a.0 UHC4 S3 disabled UHC5 S3 disabled EHC2 S3 disabled pci:0000:00:1a.7 EXP1 S4 disabled pci:0000:00:1c.0 PXSX S4 disabled pci:0000:01:00.0 EXP2 S4 disabled PXSX S4 disabled EXP3 S4 disabled PXSX S4 disabled EXP4 S4 disabled pci:0000:00:1c.3 PXSX S4 disabled pci:0000:02:00.0 EXP5 S4 disabled PXSX S4 disabled EXP6 S4 disabled PXSX S4 disabled However, the relevant bits seem to be detected from dmesg. [ 0.357628] ACPI: AC Adapter [ACAD] (on-line) [ 0.357749] input: Power Button as /devices/LNXSYSTM:00/LNXSYBUS:00/PNP0C0C:00/input/input0 [ 0.357754] ACPI: Power Button [PWRB] [ 0.357817] input: Lid Switch as /devices/LNXSYSTM:00/LNXSYBUS:00/PNP0C0D:00/input/input1 [ 0.359319] ACPI: Lid Switch [LID0] [ 0.359390] input: Sleep Button as /devices/LNXSYSTM:00/LNXSYBUS:00/PNP0C0E:00/input/input2 [ 0.359394] ACPI: Sleep Button [SLPB] [ 0.359475] input: Power Button as /devices/LNXSYSTM:00/LNXPWRBN:00/input/input3 [ 0.359479] ACPI: Power Button [PWRF] Not quite sure what to do next.

    Read the article

  • Linux commands shows different results

    - by ClydeFrog
    I'm really having a hard time to process these results on my Ubuntu server. I have a major problem with my JBoss server where I get FileNotFoundExceptions along with "No space left on device" errors. And I thought "maybe I'm out of disk space", and used df command to figure out how much I have left: root@ubuntu1:/# df -h Filsystem Storlek Anvnt Tillg Anv% Monterat på /dev/mapper/ubuntu1-root 36G 13G 21G 38% / none 2,0G 192K 2,0G 1% /dev none 2,0G 0 2,0G 0% /dev/shm none 2,0G 64K 2,0G 1% /var/run none 2,0G 0 2,0G 0% /var/lock /dev/sda1 228M 23M 193M 11% /boot /dev/mapper/vgdata-lvdata 79G 9,2G 66G 13% /data And as you can see, I have plenty of space left. And I also checked if I'm out of i-nodes: root@ubuntu1:/# df -i Filsystem Inoder IAnv IFria IAnv% Monterat på /dev/mapper/ubuntu1-root 2346512 61992 2284520 3% / none 505380 773 504607 1% /dev none 507383 1 507382 1% /dev/shm none 507383 30 507353 1% /var/run none 507383 2 507381 1% /var/lock /dev/sda1 124496 230 124266 1% /boot /dev/mapper/vgdata-lvdata 10486784 233945 10252839 3% /data But then i used du: root@ubuntu1:/# du -s -h /* 7,5M /bin 23M /boot 19G /data 192K /dev 11G /eniro 5,3M /etc 112K /home 0 /initrd.img 183M /lib 0 /lib64 16K /lost+found 12K /media 4,0K /mnt 4,0K /opt du: kan inte komma åt "/proc/20452/task/20452/fd/3": Filen eller katalogen finns inte du: kan inte komma åt "/proc/20452/task/20452/fdinfo/3": Filen eller katalogen finns inte du: kan inte komma åt "/proc/20452/fd/3": Filen eller katalogen finns inte du: kan inte komma åt "/proc/20452/fdinfo/3": Filen eller katalogen finns inte 0 /proc 18M /root 8,2M /sbin 4,0K /selinux 8,0K /srv 0 /sys 40K /tmp 691M /usr 1,2G /var 0 /vmlinuz Notice that /data and /eniro are 30G combined! How is it possible? Do I have a memory leak somewhere? Or is it something else? ----- EDIT 1 ----- Ok, I figured out that /data has its own mount so it's not possible to combine /data and /eniro because they aren't on the same mount. But how come it says 9,2G on the first command when it says 19G on the third on directory /data?

    Read the article

  • Debian - starting UFW (Uncomplicated Firewall) before network interfaces are operational

    - by Tomasz Zielinski
    I want to install UFW on Debian Lenny. Everything looks straightforward except that I don't know where to plug UFW startup script so that it configures iptables before hax0rs can break in. I've reviewed runlevel directories and in /etc/rc0.d, /etc/rc6.d and /etc/rcS.d there are items like these: S35networking -> ../init.d/networking S36ifupdown -> ../init.d/ifupdown Runlevel 0 and 6 are for shutdown and reboot so I guess nothing should be changed there, but runlevel S advertises itself (in README) like something for me: The scripts in this directory whose names begin with an 'S' are executed once when booting the system, even when booting directly into single user mode. The following sequence points are defined at this time: * After the S40 scripts have executed, all local file systems are mounted and networking is available. All device drivers have been initialized. (What bothers me is that both rc0/6.d and rcS.d point to the same networking and ifupdown scripts, but after looking at sources I believe those scripts are smart enough to figure out where to start and where to stop networking.) Now, I think that I should plug my /lib/ufw/ufw-init into /etc/rcS.d, with priority higher that the one of ifupdown and networking, i.e. <= 38 for my /etc/rcS.d. Am I right in this "analysis" ?

    Read the article

  • Tcpreplaying using VMware

    - by Methos
    This is more like a testbed setup question. I want to use VMware to debug some networking code in the linux kernel in the VM. My VM has two network interfaces. What I want to do is replay the capture file in the host and receive the packets in the VM. My problem is I do not see replayed packets in the VM. I am running VMware and tcpreplay on the host as sudo. Hence I think there should not be any problem access devices files. I am running VMware workstation 7.0 a. I first began with Custom networking as that provides option of creating your own virtual network name. I wrote /dev/vmnet3 and /dev/vmnet4 for the two interfaces respectively. However, after booting the guest, I did not see any of these interfaces or devices files (in /dev) created on the host. b. Then I tried 'Host Only', but that does not show what bridge/device file is associated with the interface. c. Finally I tried bridged networking mode. I see vmnet1, vmnet8 and vboxnet0 on the host. I have tcpreplayed the capture file on each of these interfaces, for all the above three cases. I tried to capture packets in the VM using "tcpdump -i any". However, I do not see any packets. Any ideas/pointers?

    Read the article

  • Connection refused in ssh tunnel to apache forward proxy setup

    - by arkascha
    I am trying to setup a private forward proxy in a small server. I mean to use it during a conference to tunnel my internet access through an ssh tunnel to the proxy server. So I created a virtual host inside apache-2.2 running the proxy, the proxy_http and the proxy_connect module. I use this configuration: <VirtualHost localhost:8080> ServerAdmin xxxxxxxxxxxxxxxxxxxx ServerName yyyyyyyyyyyyyyyyyyyy ErrorLog /var/log/apache2/proxy-error_log CustomLog /var/log/apache2/proxy-access_log combined <IfModule mod_proxy.c> ProxyRequests On <Proxy *> # deny access to all IP addresses except localhost Order deny,allow Deny from all Allow from 127.0.0.1 </Proxy> # The following is my preference. Your mileage may vary. ProxyVia Block ## allow SSL proxy AllowCONNECT 443 </IfModule> </VirtualHost> After restarting apache I create a tunnel from client to server: #> ssh -L8080:localhost:8080 <server address> and try to access the internet through that tunnel: #> links -http-proxy localhost:8080 http://www.linux.org I would expect to see the requested page. Instead a get a "connection refused" error. In the shell holding open the ssh tunnel I get this: channel 3: open failed: connect failed: Connection refused Anyone got an idea why this connection is refused ?

    Read the article

  • How to disable "safely remove hardware"

    - by Matt
    I have some windows 7 virtual machines in xen that have devices showing up in "safely remove hardware". I don't want users to ever be able to remove/eject any hardware at all. I'm told vmware has a hotplug option. xen doesn't seem to provide this for pci passthrough devices, therefore I'm looking for a reliable solution to prevent users from ejecting devices. This issue is not necessarily related just to virtual machines but seems to be a common problem with devices that get wrongly reported as removable. I'm ideally looking for a way to prevent all devices from appearing or just prevent the safely remove hardware option from ever coming up. I've tried setting device capabilities for specific devices on boot with a script but this for some reason doesn't always seem to work reliably. Is there a way to prevent this icon from appearing in the notification area completely, either by registry key or group policy? I should point out that setting this in group policy to "Administrators" did not seem to work. [Computer ConfigurationWindows SettingsSecurity SettingsLocal PoliciesSecurity Optionsevices:Allowed to format and eject removable media]

    Read the article

  • Which is the fastest way to move 1Petabyte from one storage to a new one?

    - by marc.riera
    First of all, thanks for reading, and sorry for asking something related to my job. I understand that this is something that I should solve by myself but as you will see its something a bit difficult. A small description: Now Storage = 1PB using DDN S2A9900 storage for the OSTs, 4 OSS , 10 GigE network. (lustre 1.6) 100 compute nodes with 2x Infiniband 1 infiniband switch with 36 ports After Storage = Previous storage + another 1PB using DDN S2A 990 or LSI E5400 (still to decide) (lustre 2.0) 8 OSS , 10GigE network 100 compute nodes with 2x Infiniband Previous experience: transfered 120 TB in less than 3 days using following command: tar -C /old --record-size 2048 -b 2048 -cf - dir | tar -C /new --record-size 2048 -b 2048 -xvf - 2>&1 | tee /tmp/dir.log So , big problem here, using big mathematical equations I conclude that we are going to need 1 month to transfer the data from one side to the new one. During this time the researchers will need to step back, and I'm personally not happy with this. I'm telling you that we have infiniband connections because I think that may be there is a chance to use it to transfer the data using 18 compute nodes (18 * 2 IB = 36 ports) to transfer the data from one storage to the other. I'm trying to figure out if the IB switch will handle all the traffic but in case it just burn up will go faster than using 10GigE. Also, having lustre 1.6 and 2.0 agents on same server works quite well, with this there is no need to go by 1.8 to upgrade the metadata servers with two steps. Any ideas? Many thanks Note 1: Zoredache, we can divide it in two blocks (A)600Tb and (B)400Tb. The idea is to move (A) to new storage which is lustre2.0 formated, then format where (A) was with lustre2.0 and move (B) to this lustre2.0 block and extend with the space where (B) was. This way we will end with (A) and (B) on separate filesystems, with 1PB each.

    Read the article

  • Can Xen be configured to dedicate only one port of a dual-port NIC to a domU?

    - by jamieb
    I'm using CentOS 5.4 on my dom0 with a stock Xen kernel. I'm attempting to use the pciback module to hide some of the Ethernet ports from the host and reserve them for a domU I intend to use for a firewall (process described here). However, when I launch the domU, I get the following error message: Using config file "/etc/xen/firewall". Error: pci: improper device assignment specified: pci: 0000:01:04.0 must be co-assigned to the same guest with 0000:01:06.0, but it is not owned by pciback. lspci gives me the following output: 00:00.0 Host bridge: Intel Corporation 82945G/GZ/P/PL Memory Controller Hub (rev 02) 00:02.0 VGA compatible controller: Intel Corporation 82945G/GZ Integrated Graphics Controller (rev 02) 00:1d.0 USB Controller: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #1 (rev 01) 00:1d.1 USB Controller: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #2 (rev 01) 00:1d.2 USB Controller: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #3 (rev 01) 00:1d.3 USB Controller: Intel Corporation 82801G (ICH7 Family) USB UHCI Controller #4 (rev 01) 00:1d.7 USB Controller: Intel Corporation 82801G (ICH7 Family) USB2 EHCI Controller (rev 01) 00:1e.0 PCI bridge: Intel Corporation 82801 PCI Bridge (rev e1) 00:1f.0 ISA bridge: Intel Corporation 82801GB/GR (ICH7 Family) LPC Interface Bridge (rev 01) 00:1f.2 IDE interface: Intel Corporation 82801GB/GR/GH (ICH7 Family) SATA IDE Controller (rev 01) 00:1f.3 SMBus: Intel Corporation 82801G (ICH7 Family) SMBus Controller (rev 01) 01:04.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL-8139/8139C/8139C+ (rev 10) 01:06.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL-8139/8139C/8139C+ (rev 10) 01:07.0 Ethernet controller: Realtek Semiconductor Co., Ltd. RTL-8139/8139C/8139C+ (rev 10) From the sound of the error message, it seems like I also need to dedicate eth0 (PCI ID 01:04.0) to the domU. Am I correct? If not, what am I doing wrong? Thanks!

    Read the article

  • Getting old bluetooth headset out of standby on Windows 7

    - by luagh45
    I think this is the problem, and if not, I'm open to suggestions. I have an old Jabra BT200 that I used to use on my phone. When a phone call was coming in it would beep using its own noises (meaning the phone never rang inside the headset) and then I could push the 'answer/hang up' button and sound and mic would start working. I have now paired it with Windows 7, and it looks good. Under the playback menu I have 'Bluetooth Hands free Audio / Jabra BT200 (Mono Audio) / Ready', and under the recording menu I have 'Bluetooth Audio Input Device / Jabra BT200 (Mono Audio) / Ready'. However when I try to test the speakers Windows sends a sound, but I never hear it, and when I talk in the mic, Windows never hears me. If I right click either the Bluetooth mic or speakers there's an option to 'Connect', but it's grayed out and I cannot click it. As the final piece of knowledge I have, my headset blinks once every 3 seconds when it's in standby and I can't get that to change. If everything was working it should blink once every second at which point I think all of my problems would be fixed. Hence my issue: I can't seem to get my headset out of standby. On my headset I've tried sending it test noises and then pressing the 'Answer' button, but still nothing. The headset beeps when I press it, so it works, it just doesn't ever come out of standby. Is there maybe some way to trick my headset into thinking it's getting a phone call from my computer?

    Read the article

  • WMI Sensors monitoring

    - by DmitrySemenov
    Monitoring tool Paessler stopped to monitor WMI Windows Sensors Paessler is Updated to version 12.4.5.3165. (10/30/2012 1:44:11 PM) Paessler windows sensors (against windows server 2008 R2 web edition) stopped to work (no changes have been made on server that we monitor) with the message Connection could not be established (80070005: Access is denied - Host: 192.168.2.10, User: Administrator, Password: **, Domain: ntlmdomain:) (code: PE015) However if I go to Virtual machine used to run Paessler and the following cscript runs successfully: strComputer = "192.168.2.10" Set objSWbemLocator = CreateObject("WbemScripting.SWbemLocator") Set objSWbemServices = objSWbemLocator.ConnectServer _ (strComputer, "root\cimv2", _ "Administrator", "pass") Set colProcessList = objSWbemServices.ExecQuery( _ "Select * From Win32_Processor") For Each objProcess in colProcessList Wscript.Echo "Process Name: " & objProcess.Name Next I'm getting output C:\>cscript test.vbs Microsoft (R) Windows Script Host Version 5.8 Copyright (C) Microsoft Corporation. All rights reserved. Process Name: Intel(R) Xeon(R) CPU X5680 @ 3.33GHz Process Name: Intel(R) Xeon(R) CPU X5680 @ 3.33GHz So WMI works a. I gave Administrator credentials for Device to monitor in Paessler setting, the same I used in the script above b. I restarted windows server (broken sensors) - but this didn't help c. I restarted Paessler probe service - no effect any ideas?

    Read the article

  • How do I create an MBR on a USB stick using DD command line tool

    - by Lana Miller
    Okay I'm trying to create a BOOTABLE Windows7 image on a USB key from a Mac running Lion. My image is .iso format. I tried: sudo dd if=/Users/myusername/Win7.iso of=/dev/disk1 bs=1m And this succeeded in writing the files, except in DISK UTILITY on the mac, it shows the partition type as GUID Partition Table and not 'Master Boor Record'. Booting the key on my Vista computer yields the error "No boot sector on USB Device' From what I can tell, bs=1m in the DD command should have left 1 Megabyte for the boot sector, but for some reason this area of the USB Key is not set up correctly so that it will boot How can I fix this, or correctly use dd to write a bootable cd image such that it is now a bootable usb drive? Note: in the instructions I read about, they recommended renaming my Win7.iso to Win7.dmg before using DD, which made absolutely no sense to me, so I didn't do it. I could try with that step now, but it takes 1.99 hours to write the image to the USB drive so there is a huge penalty to trial and error here. Thank you.

    Read the article

  • NTOP gives warnings on startup

    - by FR6
    I just installed ntop 1.4.4 and when I start it, it give me infinite warnings "packet truncated": ... RRD_DEBUG: umask 0066 RRD_DEBUG: DirPerms 0700 THREADMGMT: RRD: Started thread (t2992630672) for data collection THREADMGMT[t2992630672]: RRD: Data collection thread starting [p30923] INIT: Created pid file (/var/run/ntop.pid) THREADMGMT[t3086329552]: ntop RUNSTATE: INITNONROOT(3) Now running as requested user 'nobody' (99:99) Note: Reporting device initally set to 0 [eth0] (merged) THREADMGMT[t3086329552]: ntop RUNSTATE: RUN(4) THREADMGMT[t2982140816]: NPS(1): Started thread for network packet sniffing [eth0] THREADMGMT[t2982140816]: NPS(eth0): pcapDispatch thread starting [p30923] THREADMGMT[t2982140816]: NPS(eth0): pcapDispatch thread running [p30923] THREADMGMT[t3047009168]: SIH: Idle host scan thread running [p30923] THREADMGMT[t3057499024]: SFP: Fingerprint scan thread running [p30923] **WARNING** packet truncated (8814->8232) **WARNING** packet truncated (10274->8232) **WARNING** packet truncated (8814->8232) **WARNING** packet truncated (8814->8232) ... Do I need to configure something? I tried to access the web interface (http://localhost:3000) but it does not work. Note: I'm on CentOS. EDIT: Not sure if it helps but there is my "ifconfig": eth0 Link encap:Ethernet HWaddr 00:16:76:BC:7E:77 inet addr:192.168.0.221 Bcast:192.168.0.255 Mask:255.255.255.0 inet6 addr: fe80::216:76ff:febc:7e77/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:15496640 errors:0 dropped:0 overruns:0 frame:0 TX packets:19256813 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:836230629 (797.4 MiB) TX bytes:608496148 (580.3 MiB) Memory:dffe0000-e0000000

    Read the article

  • Single computer on network cannot connect to internet.

    - by user34630
    Hi All, I hope you can help me out! :) I have 3 computers and one device (Xbox) on my home network; 2 running XP and one on Vista. The computer that can't connect to the internet (XP) is old and failing, and shows no warning before it completely runs out of battery. Thus today, I started it up forgetting that I had unplugged it the night before, and it just ran out of battery entirely whilst I was using it and died. I think that before this I had been browsing the internet, but I can't remember for certain. (i.e. The problem I am having may or may not have been caused by this 'hard' power off). Anyway, now when I start the computer up it takes 5-10 minutes after logging on to display the start bar and icons. Also, I cannot browse the internet. The computer seems to connect to the network OK (I have tried both wired and wireless), but I can't visit sites and can't ping web addresses. Pinging the router fails, as does pinging another of my computers on the network. I have never encountered something like this before, and whilst I am no noob I am also not a sysadmin, haha. :( Any help is greatly appreciated, thank you for your time. P.S. I have tried a system restore (newbie move?).

    Read the article

  • Load balanced IIS. Should I use NLB, or linux-based reverse proxy, or something else?

    - by growse
    What would be the best approach for load-balancing at least 2-3 Windows 2008 R2 IIS webservers running a multitude of .NET applications? My choices appear to be: 1) Hardware-based network device load balancer, like a Cisco CSS 2) Windows NLB 3) Some sort of linux based proxy, either haproxy or other The three servers sit as VMs on a vSphere farm, so I have the ability to clone to up the instance count in times of high load. I control the switch that the vSphere hosts are plugged into (Cisco 3750), but don't control the switching/routing infrastructure beyond that to the clients. (1) Is too expensive, and probably overkill for my needs. I've included this in case someone figures out a cunning way to do it on my existing network kit, which I doubt. (2) would seem to be the obvious "built-in" option, but seems to be quite fiddly messing around with network interfaces, multicast, and generally other things that seem to be needlessly complex. It's also fairly stupid, in that it can't remove hosts from the pool if they start throwing 500 errors or otherwise go wrong (3) is the most interesting option, as it would appear to offer the most flexibility and customizability, but without having to mess around with the network. However, while I'm familiar with the reverse-proxy capabilities of lighttpd etc, I'm not that well read on other options like HAProxy, which might be able to offer a lot more. Which would you go for, and is there anything I've not thought of?

    Read the article

  • Nginx Tries to download file when rewriting non-existent url

    - by Vince Kronlein
    All requests to a non-existent file should be re-written to index.php?name=$1 All other requests should be processed as normal. With this server block, the server is trying to download all non-existent urls: server { server_name www.domain.com; rewrite ^(.*) http://domain.com$1 permanent; } server { listen 80; server_name domain.com; client_max_body_size 500M; index index.php index.html index.htm; root /home/username/public_html; location ~ /\.ht { deny all; } location ~ \.php$ { try_files $uri = 404; fastcgi_split_path_info ^(.+\.php)(/.+)$; include fastcgi_params; fastcgi_index index.php; fastcgi_param SCRIPT_FILENAME $document_root$fastcgi_script_name; fastcgi_pass 127.0.0.1:9002; } location ~* ^.+\.(ogg|ogv|svg|svgz|eot|otf|woff|mp4|ttf|rss|atom|jpg|jpeg|gif|png|ico|zip|tgz|gz|rar|bz2|doc|xls|exe|ppt|tar|mid|midi|wav|bmp|rtf)$ { access_log off; log_not_found off; expires max; } location /plg { } location / { if (!-f $request_filename){ rewrite ^(.*)$ /index.php?name=$1 break; } } } I've checked to see that my default_type = text/html instead of octet stream, not sure what the deal is.

    Read the article

  • Netgear GS724Tv3 and link aggregation Mac OS X Server 10.6.8

    - by Manca Weeks
    I need to link aggregate 2 sets of ports on the Netgear GS724T with my Apple server tower (latest generation). I have 2 built in ports and 2 ports on a PCIe ethernet card. It is not obvious to me how to properly configure the Netgear end. I have access to the Netgear box through its web interface, just don't know how to properly set the settings. I tried going to Netgear for help, but they said my software support has expired. I bought this unit on their recommendation - they say it is compatible with 802.3ad protocol. I cannot locate any references to this protocol in the manual and I noticed some people in formus say that this device is actually not compatible with 802.3ad and that Netgear is misleading potential customers by saying it is. Any help will be appreciated. Thanks, M My own answer - posted as edit because of restrictions on my user: OK folks, turns out one must use a Windows machine on this one or nothing makes sense. I was unable to get much farther than viewing the default inactive LAGs because in Firefox and Safari on Mac things don't make much sense - i.e. the Apply buttons (supposedly JavaScript) don't work. You can view the configurations, but none of the modifications you make stick. Then, in Switching - LAGs, choose the ports to include and make sure you switch the LAG type from Static to LACP and all is well. Haven't tested the performance of the config yet, but both sides appear to be happy with the configuration. Apple server says link active and so does the Netgear. Will report if any other discoveries. Thanks for all who read and to user84104 for responding. M

    Read the article

  • Unable to PPTP through NAT on Cisco 881

    - by MasterRoot24
    I'm trying to connect to a PPTP server which is sat behind a Cisco 881 NAT router. The server is running Ubuntu Server 12.04 and is running Poptop pptpd as the PPTP daemon listening for connections. As discussed in my other question, I'm trying to setup a Cisco 881 router to replace my old Linksys WAG320N. This same server and WAN connection worked fine with the WAG320N with no special configuration, other than allowing 1723 in through the firewall. On the Cisco 881, I'm using the newer ip nat enable or NAT NVI to setup static routes in through the firewall for the services running behind the router. My reason being that I can't run another copy of my live DNS domains internally with local IP addresses in. For the purposes of this question, though, I have rebuilt the router with ip nat inside/outside style NAT'ing, but this issue is still apparent. HTTP/SMTP/IMAP etc. all work ok from both the WAN and LAN interfaces of the router. I'm only having issues with SIP (see other question) and PPTP. My issue is that the GRE doesn't appear to be passing through NAT correctly and one end of the connection is not receiving GRE traffic when it should be, so the server hangs up the connection. Here's an example of /var/log/syslog with debug enabled in /etc/pptpd.conf: Dec 11 21:06:30 <HOSTNAME> pptpd[22626]: MGR: Launching /usr/sbin/pptpctrl to handle client Dec 11 21:06:30 <HOSTNAME> pptpd[22626]: CTRL: local address = 192.168.1.50 Dec 11 21:06:30 <HOSTNAME> pptpd[22626]: CTRL: remote address = 192.168.1.51 Dec 11 21:06:30 <HOSTNAME> pptpd[22626]: CTRL: pppd options file = /etc/ppp/pptpd-options Dec 11 21:06:30 <HOSTNAME> pptpd[22626]: CTRL: Client 82.132.248.216 control connection started Dec 11 21:06:30 <HOSTNAME> pptpd[22626]: CTRL: Received PPTP Control Message (type: 1) Dec 11 21:06:30 <HOSTNAME> pptpd[22626]: CTRL: Made a START CTRL CONN RPLY packet Dec 11 21:06:30 <HOSTNAME> pptpd[22626]: CTRL: I wrote 156 bytes to the client. Dec 11 21:06:30 <HOSTNAME> pptpd[22626]: CTRL: Sent packet to client Dec 11 21:06:30 <HOSTNAME> pptpd[22626]: CTRL: Received PPTP Control Message (type: 7) Dec 11 21:06:30 <HOSTNAME> pptpd[22626]: CTRL: Set parameters to 100000000 maxbps, 64 window size Dec 11 21:06:30 <HOSTNAME> pptpd[22626]: CTRL: Made a OUT CALL RPLY packet Dec 11 21:06:30 <HOSTNAME> pptpd[22626]: CTRL: Starting call (launching pppd, opening GRE) Dec 11 21:06:30 <HOSTNAME> pptpd[22626]: CTRL: pty_fd = 6 Dec 11 21:06:30 <HOSTNAME> pptpd[22626]: CTRL: tty_fd = 7 Dec 11 21:06:30 <HOSTNAME> pptpd[22626]: CTRL: I wrote 32 bytes to the client. Dec 11 21:06:30 <HOSTNAME> pptpd[22626]: CTRL: Sent packet to client Dec 11 21:06:30 <HOSTNAME> pptpd[22627]: CTRL (PPPD Launcher): program binary = /usr/sbin/pppd Dec 11 21:06:30 <HOSTNAME> pptpd[22627]: CTRL (PPPD Launcher): local address = 192.168.1.50 Dec 11 21:06:30 <HOSTNAME> pptpd[22627]: CTRL (PPPD Launcher): remote address = 192.168.1.51 Dec 11 21:06:30 <HOSTNAME> pppd[22627]: Plugin /usr/lib/pptpd/pptpd-logwtmp.so loaded. Dec 11 21:06:30 <HOSTNAME> pppd[22627]: pppd 2.4.5 started by root, uid 0 Dec 11 21:06:30 <HOSTNAME> pppd[22627]: Using interface ppp0 Dec 11 21:06:30 <HOSTNAME> pppd[22627]: Connect: ppp0 <--> /dev/pts/3 Dec 11 21:06:30 <HOSTNAME> pptpd[22626]: GRE: Bad checksum from pppd. Dec 11 21:06:31 <HOSTNAME> pptpd[22626]: CTRL: Received PPTP Control Message (type: 15) Dec 11 21:06:31 <HOSTNAME> pptpd[22626]: CTRL: Got a SET LINK INFO packet with standard ACCMs Dec 11 21:07:00 <HOSTNAME> pppd[22627]: LCP: timeout sending Config-Requests Dec 11 21:07:00 <HOSTNAME> pppd[22627]: Connection terminated. Dec 11 21:07:00 <HOSTNAME> avahi-daemon[1042]: Withdrawing workstation service for ppp0. Dec 11 21:07:00 <HOSTNAME> pppd[22627]: Modem hangup Dec 11 21:07:00 <HOSTNAME> pppd[22627]: Exit. Dec 11 21:07:00 <HOSTNAME> pptpd[22626]: GRE: read(fd=6,buffer=6075a0,len=8196) from PTY failed: status = -1 error = Input/output error, usually caused by unexpected termination of pppd, check option syntax and pppd logs Dec 11 21:07:00 <HOSTNAME> pptpd[22626]: CTRL: PTY read or GRE write failed (pty,gre)=(6,7) Dec 11 21:07:00 <HOSTNAME> pptpd[22626]: CTRL: Reaping child PPP[22627] Dec 11 21:07:00 <HOSTNAME> pptpd[22626]: CTRL: Client 82.132.248.216 control connection finished Dec 11 21:07:00 <HOSTNAME> pptpd[22626]: CTRL: Exiting now Dec 11 21:07:00 <HOSTNAME> pptpd[5803]: MGR: Reaped child 22626 As far as Cisco are concerned, all I need is ip nat source static tcp <SERVER LAN IP> 1723 interface FastEthernet4 1723 but of course this doesn't seem to the be helping the GRE traffic through as it should. Trying the connection to the LAN IP of the server from the same LAN as the server (behind the router), the PPTP connection works fine, so I'm confident that the server's config is ok. Furthermore, all I needed on my WAG320N was to open 1723 in the firewall. Here's my current router config: ! ! Last configuration change at 20:20:15 UTC Tue Dec 11 2012 by xxx version 15.2 no service pad service timestamps debug datetime msec service timestamps log datetime msec service password-encryption ! hostname xxx ! boot-start-marker boot-end-marker ! ! enable secret 4 xxxx ! aaa new-model ! ! aaa authentication login local_auth local ! ! ! ! ! aaa session-id common ! memory-size iomem 10 ! crypto pki trustpoint TP-self-signed-xxx enrollment selfsigned subject-name cn=IOS-Self-Signed-Certificate-xxx revocation-check none rsakeypair TP-self-signed-xxx ! ! crypto pki certificate chain TP-self-signed-xxx certificate self-signed 01 xxx quit ip gratuitous-arps ip auth-proxy max-login-attempts 5 ip admission max-login-attempts 5 ! ! ! ! ! ip domain list dmz.xxx.local ip domain list xxx.local ip domain name dmz.xxx.local ip name-server 192.168.1.x ip cef login block-for 3 attempts 3 within 3 no ipv6 cef ! ! multilink bundle-name authenticated license udi pid CISCO881-SEC-K9 sn xxx ! ! username admin privilege 15 secret 4 xxx username joe secret 4 xxx ! ! ! ! ! ip ssh time-out 60 ! ! ! ! ! ! ! ! ! interface FastEthernet0 no ip address ! interface FastEthernet1 no ip address ! interface FastEthernet2 no ip address ! interface FastEthernet3 switchport access vlan 2 no ip address ! interface FastEthernet4 ip address dhcp ip nat enable duplex auto speed auto ! interface Vlan1 ip address 192.168.1.x 255.255.255.0 no ip redirects no ip unreachables no ip proxy-arp ip nat enable ! interface Vlan2 ip address 192.168.0.x 255.255.255.0 ! ip forward-protocol nd ip http server ip http access-class 1 ip http authentication local ip http secure-server ! ! ip nat source list 1 interface FastEthernet4 overload ip nat source list 2 interface FastEthernet4 overload ip nat source static tcp 192.168.1.x 1723 interface FastEthernet4 1723 ! ! access-list 1 permit 192.168.0.0 0.0.0.255 access-list 2 permit 192.168.1.0 0.0.0.255 ! ! ! ! control-plane ! ! banner motd Authorized Access only ! line con 0 exec-timeout 15 0 login authentication local_auth line aux 0 exec-timeout 15 0 login authentication local_auth line vty 0 4 access-class 2 in login authentication local_auth length 0 transport input all ! ! end UPDATE 16/12/2012: The only progress that I have been able to make on this issue is that I'm confident that the issue is caused by the GRE tunnels (which are required for the PPTP connection to complete) are being blocked. When attempting a connection, I can see in show ip nat nvi translations that both a TCP translation on 1723 is setup and also a GRE translation is setup also. I appear to be able to see GRE related packets on the LAN that the server is on, so I am lead to believe that the server is sending(?) GRE packets, however running Wireshark on a client PC when attempting a connection shows absolutely no GRE packets. Whilst there are no configuration directives in my config posted above (that I can pin point) which would specifically block them, it would appear that the GRE packets are not being allowed in/out of the router's firewall, even though a NAT translation entry is setup to the server's LAN address. Would anyone be able to provide me with some help to ensure that GRE packets are not blocked by the router's firewall, so that this can be ruled out as a possible issue please?

    Read the article

  • Kindle (client) for Mac

    - by doug
    So we're clear, i'm talking bout the client/software version here--ie, that you install on your Mac or PC--not the device. The Kindle client was recently released for the Mac. I bought a couple of Kindle-edition books and i'm reading them using this client. Astonishingly, two features i consider to be more or less essential to any ebook reader are missing in the Kindle client, either that, or i can't find them: (i) text searching; and (ii) highlighting text. First, does anyone know how to access the search feature? I'm aware of the "Go To" button at the top middle of the reader window--the options in that menu when you click the button are: "Cover", "Table of Contents", "Beginning" and "Location." "Location" requires that you type in an integer (but it doesn't correspond to page number--e.g., typing "167" brought me to the table of contents), not a search term. Second, there's a button on the upper right-hand corner of the window "Show Notes and Marks" yet i can't find any way to highlight text. The only kind of "note" or "mark" i have been able to record is to "bookmark" a page by clicking the "bookmark" button also at the top of the window.

    Read the article

  • Eee PC Seashell series netbook screen is cut off at bottom no matter the resolution

    - by Yzmir Ramirez
    I have an Eee PC 1015PE Seashell netbook running Windows 7 Home Premium with an Intel Graphics Media Accelerator 3150 (8.14.10.2230) with a "Generic Non-PnP Monitor" detected. I tried: Changing the resolution (Control Panel = Appearance and Personalization = Display = Screen Resolution) to 1024x768 Updating the video driver (to 8.14.10.2230) Uninstalling the driver and rebooting Pressing the Windows Key + "-" (magnifier) Pressing Ctrl + Mouse Scroll only resizes the desktop items Pressing Fn + F4 shows 1024x600 (which I think is what I should be using, but nothing happens) EDIT: Changed from Landscape to Portrait and it works Attached an External Monitor and when I extend or set as desktop it works only on the External Monitor (shows up as "Generic PnP Monitor in Device Manager) Basically the bottom inch of my desktop is off-screen hiding my start bar, but my wigets are in their proper position (the start bar is not hidden). Pressing Ctrl + Esc shows the start menu but its cut-off. I'm pretty sure I should be using 1024x600 resolution, any advice? What's odd is that this only started happening recently. EDIT2: Here are some screenshots showing the problem: Resized Window to fit: Opened Start Menu - notice it cut off: Maximized window and then scrolled down - notice no Start Menu: I downgraded my graphic driver I downloaded from the Intel Download Center for the Graphic Media Accelerator 3150 (now: 8.14.10.1972) and now my "Generic non-PnP Montior" detects as "Digital Flat Panel (1024x768 60Hz)".

    Read the article

  • how would it be possible to discover a cable modem's MAC remotely?

    - by amateurenthusiast
    i was reading the back archives of a canadian privacy law blog, and he linked to a judicial decision. apparently as part of an investigation in which were used yahoo chat and google's old 'hello' image trading program the officer was able to determine a suspect's modem's MAC address: In order to determine who STEPHTOSH was, the officer did a trace on a programme called WHO IS in an effort to learn from where STEPHTOSH was coming. WHO IS is a command program available to the public. The officer was able to ascertain that the person using the name STEPHTOSH was a Rogers Internet customer. The officer was able to obtain the Internet Protocol address, also known as the I.P. There is only one location for an I.P., which is unique to that subscriber. By use of the website known as DNS STUFF.com, one is able to find with which company this I.P. is registered. It was ascertained that the I.P. address used by STEPHTOSH was registered to Rogers Cable, from the Toronto area. The officer also learned the Cable Modem MAC address used by STEPHTOSH. This was all the information the officer was able to amass. now it was my understanding that the MAC address of any given device can only be accessed if you're only one 'hop' away on the Internet. the suspect in question was in Markham and the officer part of the Toronto Police, so it's conceivable that they both might have used Rogers internet. but would that still put them only one 'hop' away from each other? i thought the first hop after the modem was usually the ISP? and if he'd used a netBIOS query against this guy's machine it would return the ethernet card's MAC, not the modem's. so is this guy on the same rogers subnet as the suspect's cable modem, is that functionality part of google's Hello (i could only think that it would be possible if Hello operated as a virtual LAN or something), does the officer have remote access to the arp caches of the routers at Rogers or is he just full of crap and lying to make his case stronger?

    Read the article

  • Possible to host CentOS netinstall files on a local HTTP/FTP?

    - by garlicman
    I'm running XenServer on an Dell R610 and am running into a catch-22. During install from DVD, CentOS can't find the DVD package catalogue. It's a reported error for some, XenServer + CentOS6 + DVD install in some hardware configurations = failed install. Yes, I checked the MD5 and let the disc test pass. In every reported case, the netinstall was the solution. The issue is my net access is required to go through a web proxy that prompts before you can download a file. This naturally breaks any download automation. I've been waiting on our IT to put in an exception rule to allow my lab to bypass the prompt, but it's been over 3 weeks now and they don't seem responsive. (I've been working on this a day or two a week) I want to try and host the netinstall files local in my Xen network. Right now I only have a bunch of Windows based VMs, CentOS won't install so I don't have any Linux tools. I had tried simply hosting all the DVD contents off one of the Windows servers using Mongoose. (I didn't want to setup IIS) I copied them to a hosted sub-directory similar to all the mirrors out there (e.g. http:///centos/6.2/os/i386/) with no auth or anything. Then in the netinstall I correctly pointed to it. I now realize just copying the DVD files over won't work. The repodata will point to a local device, not the site I'm hosting. (e.g. the DVD repodata includes xml that points to where the packages are) Clearly I'm hosting them over HTTP, not from a DVD. Is there an easy way to sort this out? I'm just trying to install CentOS6 on Xen. If there's a turnkey downloadable Xen image with CentOS 6.2 on it, or a downloadable repo image, I'll take that too! Thank you in advance!

    Read the article

  • Can I get ethernet out of my Verizon FIOS set-top box?

    - by Tom Hughes
    Setup: my home network is long & skinny, and the FIOS-connected router is all the way at one of the apartment. At the other end, far away (and a floor higher) is my HD TV, which gets a cable-TV signal from a Verizon set-top box that is coax-connected back to the FIOS on-premises equipment. Wi-Fi won't work, the apartment is too stretched out, with old, thick walls and floors. Goal: I think there are three ways to get ethernet back to where the HD TV is: 1) run a cable! this isn't crazy but isn't cheap either (my building won't let me do it, it involves hiring an electrician because the cable would run partly through the public hallway ceiling) 2) split the coax near the TV and put in... a MoCA device? 3) somehow tease the set-top box, which has an RJ-11 (ethernet) port on the back, to give me network access. Question: any other choices? and, is one choice better than the others? #3 is by far the most desirable because it would involve the least wiring -- but I can't find any resources to help make it happen. #2 is a bit scary, I don't want to degrade service to the TV or anywhere else for that matter.

    Read the article

  • Relation between server_name in nginx sites-available, /etc/hosts file and A-records

    - by user2818584
    I have the following two server-blocks in my config-file in sites-available: server { listen 80; server_name www.mydomain.be; root /usr/share/nginx/html; index index.html index.htm; location / { try_files $uri $uri/ =404; } } server { listen 80; server_name sub.mydomain.be; root /usr/share/nginx/sub; index index.html index.htm; location / { try_files $uri $uri/ =404; } } I also created an A-record for both www.domain.be and sub.domain.be with the IP of my server as value. Yet, when I try to reload my nginx configuration with service nginx reload it fails. When I remove the second server-block, it reloads as expected. I know this topic is popular, and that there are loads of such [nginx][subdomain] questions here, but none of them seems to discuss explicitly how the following three things hang together: virtual hosts or server blocks in nginx (est. server_name matching) the effect of A-records on how nginx processes requests the need to add hosts to /etc/hosts Right now I have the impression that a lack of knowledge of this bigger picture, rather than specific knowledge of nginx configuration prevents me from making this work.

    Read the article

  • Is current SATA 6 gb/s equipment simply unreliable?

    - by korkman
    I have a 45-disk array of Seagate Barracuda 3 TB ST3000DM001 (yes these are desktop drives I'm aware of that) in a Supermicro sc847 JBOD, connected via LSI 9285. I have found a solution for the problem description below by reducing speed via MegaCli -PhySetLinkSpeed -phy0 2 -a0; for i in $(seq 48); do MegaCli -PhySetLinkSpeed -phy${i} 2 -a0; done and rebooting. The question remains: Is this typical for current 6 gb/s equipment? Is this the sad state of SATA storage? Or is some of my equipment (the sff-8088 cables come to mind) bad? The Problem was: Synchronizing HW RAID-6, disks kept offlining. Fetching SMART values reveiled that those which offlined did not increase powered-on hours anymore. That is, their firmware (CC4C) seems to crash. Digging into the matter by switching to Software RAID-6, with the disks passed-through, I got tons of kernel messages scattered across all disks, with 6 gb/s: sd 0:0:9:0: [sdb] Sense Key : No Sense [current] Info fld=0x0 sd 0:0:9:0: [sdb] Add. Sense: No additional sense information And finally, when a disk offlines: megasas: [ 5]waiting for 160 commands to complete ... megasas: [35]waiting for 159 commands to complete ... megasas: [155]waiting for 156 commands to complete ... megaraid_sas: pending commands remain after waiting, will reset adapter. Ugly controller reset here, then minutes later: megaraid_sas: Reset successful. sd 0:0:28:0: Device offlined - not ready after error recovery ... sd 0:0:28:0: [sdu] Unhandled error code sd 0:0:28:0: [sdu] Result: hostbyte=DID_ERROR driverbyte=DRIVER_OK sd 0:0:28:0: [sdu] CDB: Read(10): 28 00 23 21 2f 40 00 00 70 00 sd 0:0:28:0: [sdu] killing request Reduced speed to 3 gb/s like written above, all problems vanished.

    Read the article

< Previous Page | 537 538 539 540 541 542 543 544 545 546 547 548  | Next Page >