  • Is this a bug? : I get " The type ... is not a complex type or an entity type" in my WCF data servic

    - by veertien
    When invoking a query on the data service I get this error message inside the XML feed: <m:error> <m:code></m:code> <m:message xml:lang="nl-NL">Internal Server Error. The type 'MyType' is not a complex type or an entity type.</m:message> </m:error> When I use the example described here in the article "How to: Create a Data Service Using the Reflection Provider (WCF Data Services)" http://msdn.microsoft.com/en-us/library/dd728281(v=VS.100).aspx it works as expected. I have created the service in a .NET 4.0 web project. My data context class returns a query object that is derived from the LINQExtender (http://linqextender.codeplex.com/). When I execute the query object in a unit test, it works as expected. My entity type is defined as: [DataServiceKey("Id")] public class Accommodation { [UniqueIdentifier] [OriginalFieldName("EntityId")] public string Id { get; set; } [OriginalFieldName("AccoName")] public string Name { get; set; } } (the UniqueIdentifier and OriginalFieldName attributes are used by LINQExtender) Does anybody know if this is a bug in WCF data services or am I doing something wrong?

    Read the article

  • Webbased data modelling and management tool

    - by pixeldude
    Is there a web-based tool available, where I am able to... ...define data models (like in a database admin tool) ...fill in data (in custom web forms, not too generic) with basic features like completion ...import data from CSV oder Excel Sheets ...export data to CSV or SQL ...create snapshots of my data models (versions, diff, etc.) ...share my data models ...discuss/collaborate with other people about my data models Well, I can develop something like this in PHP or with Ruby or whatever. But this is such a common task, where the application support could be a lot better. And it would be language and database independent. This would help to maintain data models in different versions and you can maybe share your data models with others, extend it with your team members, etc. There is a website called FreeBase, which allows you to define a data entity model and fill in data, which also has export features, but I need to define my own data model with my own granularity and structure. And it should not be shared in public if I don't want to. How do you solve problems like this yourself?

    Read the article

  • Prevent two users from editing the same data

    - by Industrial
    Hi everyone, I have seen a feature in different web applications including Wordpress (not sure?) that warns a user if he/she opens an article/post/page/whatever from the database, while someone else is editing the same data simultaneously. I would like to implement the same feature in my own application and I have given this a bit of thought. Is the following example a good practice on how to do this? It goes a little something like this: 1) User A enters a the editing page for the mysterious article X. The database tableEvents is queried to make sure that no one else is editing the same page for the moment, which no one is by then. A token is then randomly being generated and is inserted into a database table called Events. 1) User B also want's to make updates to the article X. Now since our User A already is editing the article, the Events table is queried and looks like this: | timestamp | owner | Origin | token | ------------------------------------------------------------ | 1273226321 | User A | article-x | uniqueid## | 2) The timestamp is being checked. If it's valid and less than say 100 seconds old, a message appears and the user cannot make any changes to the requested article X: Warning: User A is currently working with this article. In the meantime, editing cannot be done. Please do something else with your life. 3) If User A decides to go on and save his changes, the token is posted along with all other data to update the database, and toggles a query to delete the row with token uniqueid##. If he decides to do something else instead of committing his changes, the article X will still be available for editing in 100 seconds for User B Let me know what you think about this approach! Wish everyone a great weekend!

    Read the article

  • Advanced Data Source Engine coming to Telerik Reporting Q1 2010

    This is the final blog post from the pre-release series. In it we are going to share with you some of the updates coming to our reporting solution in Q1 2010. A new Declarative Data Source Engine will be added to Telerik Reporting, that will allow full control over data management, and deliver significant gains in rendering performance and memory consumption. Some of the engines new features will be: Data source parameters - those parameters will be used to limit data retrieved from the data source to just the data needed for the report. Data source parameters are processed on the data source side, however only queried data is fetched to the reporting engine, rather than the full data source. This leads to lower memory consumption, because data operations are performed on queried data only, rather than on all data. As a result, only the queried data needs to be stored in the memory vs. the whole dataset, which was the case with the old approach Support for stored procedures - they will assist in achieving a consistent implementation of logic across applications, and are especially practical for performing repetitive tasks. A stored procedure stores the SQL statements and logic, which can then be executed in different reports and/or applications. Stored Procedures will not only save development time, but they will also improve performance, because each stored procedure is compiled on the data base server once, and then is reutilized. In Telerik Reporting, the stored procedure will also be parameterized, where elements of the SQL statement will be bound to parameters. These parameterized SQL queries will be handled through the data source parameters, and are evaluated at run time. Using parameterized SQL queries will improve the performance and decrease the memory footprint of your application, because they will be applied directly on the database server and only the necessary data will be downloaded on the middle tier or client machine; Calculated fields through expressions - with the help of the new reporting engine you will be able to use field values in formulas to come up with a calculated field. A calculated field is a user defined field that is computed "on the fly" and does not exist in the data source, but can perform calculations using the data of the data source object it belongs to. Calculated fields are very handy for adding frequently used formulas to your reports; Improved performance and optimized in-memory OLAP engine - the new data source will come with several improvements in how aggregates are calculated, and memory is managed. As a result, you may experience between 30% (for simpler reports) and 400% (for calculation-intensive reports) in rendering performance, and about 50% decrease in memory consumption. Full design time support through wizards - Declarative data sources are a great advance and will save developers countless hours of coding. In Q1 2010, and true to Telerik Reportings essence, using the new data source engine and its features requires little to no coding, because we have extended most of the wizards to support the new functionality. The newly extended wizards are available in VS2005/VS2008/VS2010 design-time. More features will be revealed on the product's what's new page when the new version is officially released in a few days. Also make sure you attend the free webinar on Thursday, March 11th that will be dedicated to the updates in Telerik Reporting Q1 2010. Did you know that DotNetSlackers also publishes .net articles written by top known .net Authors? We already have over 80 articles in several categories including Silverlight. Take a look: here.

    Read the article

  • Error in installing ZTE AC2738 on ubuntu 3.0.0-12-generic

    - by Netro
    I am getting this error ,struct usb_serial_driver has no member named shutdown. I am installing on 64bit ubuntu 3.0.0-12-generic ... Beginning Verify CD ... ... Verify CD Succeed! ... Beginning Copy Install Package Files ... ... will take a long time, waiting 5 seconds, please ... Copy Install Package Files Succeed! ... 'ztemtApp' previous version not found. and install now Beginning install ... ... Current linux release version is 'Ubuntu' ... Checking 'App' process ... Checking old installation ... Installing ... Current Path is : . : /tmp/ztemt_datacard/Linux 1. Checking Previous Version ... 2. Copying Data Bin ... ... will take a few seconds, please waiting ... /tmp/ztemt_datacard/Linux 3. Auto Load Usb Driver Module ... Rather than invoking init scripts through /etc/init.d, use the service(8) utility, e.g. service acpid restart Since the script you are attempting to invoke has been converted to an Upstart job, you may also use the stop(8) and then start(8) utilities, e.g. stop acpid ; start acpid. The restart(8) utility is also available. acpid stop/waiting acpid start/running, process 11802 4. Changing pppd Options ... 5. Changing File Permission ... 6. Deleting Qt lib When Local QT Vertion > V4.4.0 ... ... Package 'libqtgui4' exist ... QT_VERSION = 4 7. Deleting process id file: EVDOApp.pid ... 8. Making USB Serial Driver Module : ztemt.ko ... ... will take a few seconds, please waiting ... make -C /lib/modules/3.0.0-12-generic/build M=/usr/local/bin/ztemtApp/zteusbserial/below2.6.27 modules make[1]: Entering directory `/usr/src/linux-headers-3.0.0-12-generic' CC [M] /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.o /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c: In function ‘destroy_serial’: /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:159:14: error: ‘struct usb_serial_driver’ has no member named ‘shutdown’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:165:18: error: ‘struct usb_serial_port’ has no member named ‘open_count’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c: In function ‘serial_open’: /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:241:36: error: ‘struct usb_serial_port’ has no member named ‘mutex’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:246:8: error: ‘struct usb_serial_port’ has no member named ‘open_count’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:251:6: error: ‘struct usb_serial_port’ has no member named ‘tty’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:253:10: error: ‘struct usb_serial_port’ has no member named ‘open_count’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:265:3: warning: passing argument 1 of ‘serial->type->open’ from incompatible pointer type [enabled by default] /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:265:3: note: expected ‘struct tty_struct *’ but argument is of type ‘struct usb_serial_port *’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:265:3: warning: passing argument 2 of ‘serial->type->open’ from incompatible pointer type [enabled by default] /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:265:3: note: expected ‘struct usb_serial_port *’ but argument is of type ‘struct file *’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:270:20: error: ‘struct usb_serial_port’ has no member named ‘mutex’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:276:6: error: ‘struct usb_serial_port’ has no member named ‘open_count’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:278:6: error: ‘struct usb_serial_port’ has no member named ‘tty’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:279:20: error: ‘struct usb_serial_port’ has no member named ‘mutex’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c: In function ‘serial_close’: /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:355:18: error: ‘struct usb_serial_port’ has no member named ‘mutex’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:357:10: error: ‘struct usb_serial_port’ has no member named ‘open_count’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:358:21: error: ‘struct usb_serial_port’ has no member named ‘mutex’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:371:8: error: ‘struct usb_serial_port’ has no member named ‘open_count’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:372:10: error: ‘struct usb_serial_port’ has no member named ‘open_count’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:375:3: error: too many arguments to function ‘port->serial->type->close’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:377:11: error: ‘struct usb_serial_port’ has no member named ‘tty’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:378:12: error: ‘struct usb_serial_port’ has no member named ‘tty’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:379:9: error: ‘struct usb_serial_port’ has no member named ‘tty’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:380:8: error: ‘struct usb_serial_port’ has no member named ‘tty’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:386:20: error: ‘struct usb_serial_port’ has no member named ‘mutex’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c: In function ‘serial_write’: /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:407:11: error: ‘struct usb_serial_port’ has no member named ‘open_count’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:413:2: warning: passing argument 1 of ‘port->serial->type->write’ from incompatible pointer type [enabled by default] /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:413:2: note: expected ‘struct tty_struct *’ but argument is of type ‘struct usb_serial_port *’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:413:2: warning: passing argument 2 of ‘port->serial->type->write’ from incompatible pointer type [enabled by default] /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:413:2: note: expected ‘struct usb_serial_port *’ but argument is of type ‘const unsigned char *’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:413:2: warning: passing argument 3 of ‘port->serial->type->write’ makes pointer from integer without a cast [enabled by default] /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:413:2: note: expected ‘const unsigned char *’ but argument is of type ‘int’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:413:2: error: too few arguments to function ‘port->serial->type->write’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c: In function ‘serial_write_room’: /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:429:11: error: ‘struct usb_serial_port’ has no member named ‘open_count’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:435:2: warning: passing argument 1 of ‘port->serial->type->write_room’ from incompatible pointer type [enabled by default] /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:435:2: note: expected ‘struct tty_struct *’ but argument is of type ‘struct usb_serial_port *’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c: In function ‘serial_chars_in_buffer’: /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:451:11: error: ‘struct usb_serial_port’ has no member named ‘open_count’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:457:2: warning: passing argument 1 of ‘port->serial->type->chars_in_buffer’ from incompatible pointer type [enabled by default] /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:457:2: note: expected ‘struct tty_struct *’ but argument is of type ‘struct usb_serial_port *’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c: In function ‘serial_throttle’: /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:472:11: error: ‘struct usb_serial_port’ has no member named ‘open_count’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:479:3: warning: passing argument 1 of ‘port->serial->type->throttle’ from incompatible pointer type [enabled by default] /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:479:3: note: expected ‘struct tty_struct *’ but argument is of type ‘struct usb_serial_port *’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c: In function ‘serial_unthrottle’: /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:491:11: error: ‘struct usb_serial_port’ has no member named ‘open_count’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:498:3: warning: passing argument 1 of ‘port->serial->type->unthrottle’ from incompatible pointer type [enabled by default] /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:498:3: note: expected ‘struct tty_struct *’ but argument is of type ‘struct usb_serial_port *’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c: In function ‘serial_ioctl’: /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:511:11: error: ‘struct usb_serial_port’ has no member named ‘open_count’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:518:3: warning: passing argument 1 of ‘port->serial->type->ioctl’ from incompatible pointer type [enabled by default] /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:518:3: note: expected ‘struct tty_struct *’ but argument is of type ‘struct usb_serial_port *’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:518:3: warning: passing argument 2 of ‘port->serial->type->ioctl’ makes integer from pointer without a cast [enabled by default] /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:518:3: note: expected ‘unsigned int’ but argument is of type ‘struct file *’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:518:3: error: too many arguments to function ‘port->serial->type->ioctl’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c: In function ‘serial_set_termios’: /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:535:11: error: ‘struct usb_serial_port’ has no member named ‘open_count’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:542:3: warning: passing argument 1 of ‘port->serial->type->set_termios’ from incompatible pointer type [enabled by default] /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:542:3: note: expected ‘struct tty_struct *’ but argument is of type ‘struct usb_serial_port *’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:542:3: warning: passing argument 2 of ‘port->serial->type->set_termios’ from incompatible pointer type [enabled by default] /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:542:3: note: expected ‘struct usb_serial_port *’ but argument is of type ‘struct termios *’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:542:3: error: too few arguments to function ‘port->serial->type->set_termios’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c: In function ‘serial_break’: /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:554:11: error: ‘struct usb_serial_port’ has no member named ‘open_count’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:561:3: warning: passing argument 1 of ‘port->serial->type->break_ctl’ from incompatible pointer type [enabled by default] /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:561:3: note: expected ‘struct tty_struct *’ but argument is of type ‘struct usb_serial_port *’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c: In function ‘serial_tiocmget’: /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:629:11: error: ‘struct usb_serial_port’ has no member named ‘open_count’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:635:3: warning: passing argument 1 of ‘port->serial->type->tiocmget’ from incompatible pointer type [enabled by default] /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:635:3: note: expected ‘struct tty_struct *’ but argument is of type ‘struct usb_serial_port *’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:635:3: error: too many arguments to function ‘port->serial->type->tiocmget’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c: In function ‘serial_tiocmset’: /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:651:11: error: ‘struct usb_serial_port’ has no member named ‘open_count’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:657:3: warning: passing argument 1 of ‘port->serial->type->tiocmset’ from incompatible pointer type [enabled by default] /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:657:3: note: expected ‘struct tty_struct *’ but argument is of type ‘struct usb_serial_port *’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:657:3: warning: passing argument 2 of ‘port->serial->type->tiocmset’ makes integer from pointer without a cast [enabled by default] /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:657:3: note: expected ‘unsigned int’ but argument is of type ‘struct file *’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:657:3: error: too many arguments to function ‘port->serial->type->tiocmset’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c: In function ‘usb_serial_port_work’: /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:697:12: error: ‘struct usb_serial_port’ has no member named ‘tty’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c: In function ‘port_release’: /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:709:2: error: ‘struct device’ has no member named ‘bus_id’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c: In function ‘usb_serial_probe’: /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:858:2: error: implicit declaration of function ‘lock_kernel’ [-Werror=implicit-function-declaration] /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:861:3: error: implicit declaration of function ‘unlock_kernel’ [-Werror=implicit-function-declaration] /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:1034:3: error: ‘struct usb_serial_port’ has no member named ‘mutex’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:1182:23: error: ‘struct device’ has no member named ‘bus_id’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:1182:51: error: ‘struct device’ has no member named ‘bus_id’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:1183:3: error: ‘struct device’ has no member named ‘bus_id’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c: In function ‘usb_serial_disconnect’: /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:1257:13: error: ‘struct usb_serial_port’ has no member named ‘tty’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:1258:21: error: ‘struct usb_serial_port’ has no member named ‘tty’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c: At top level: /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:1280:2: warning: initialization from incompatible pointer type [enabled by default] /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:1280:2: warning: (near initialization for ‘serial_ops.ioctl’) [enabled by default] /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:1281:2: warning: initialization from incompatible pointer type [enabled by default] /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:1281:2: warning: (near initialization for ‘serial_ops.set_termios’) [enabled by default] /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:1284:2: warning: initialization from incompatible pointer type [enabled by default] /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:1284:2: warning: (near initialization for ‘serial_ops.break_ctl’) [enabled by default] /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:1286:2: error: unknown field ‘read_proc’ specified in initializer /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:1286:2: warning: initialization from incompatible pointer type [enabled by default] /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:1286:2: warning: (near initialization for ‘serial_ops.ioctl’) [enabled by default] /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:1287:2: warning: initialization from incompatible pointer type [enabled by default] /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:1287:2: warning: (near initialization for ‘serial_ops.tiocmget’) [enabled by default] /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:1288:2: warning: initialization from incompatible pointer type [enabled by default] /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:1288:2: warning: (near initialization for ‘serial_ops.tiocmset’) [enabled by default] /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c: In function ‘usb_serial_init’: /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:1352:2: error: implicit declaration of function ‘info’ [-Werror=implicit-function-declaration] /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c: In function ‘fixup_generic’: /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:1406:2: error: ‘struct usb_serial_driver’ has no member named ‘shutdown’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:1406:2: error: ‘struct usb_serial_driver’ has no member named ‘shutdown’ /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:1406:1: error: ‘usb_serial_generic_shutdown’ undeclared (first use in this function) /usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.c:1406:1: note: each undeclared identifier is reported only once for each function it appears in cc1: some warnings being treated as errors make[2]: *** [/usr/local/bin/ztemtApp/zteusbserial/below2.6.27/usb-serial.o] Error 1 make[1]: *** [_module_/usr/local/bin/ztemtApp/zteusbserial/below2.6.27] Error 2 make[1]: Leaving directory `/usr/src/linux-headers-3.0.0-12-generic' make: *** [modules] Error 2 Install finished! Any suggestion? Update: from installation document , In some special cases, the setup package can’t automatically compile the driver, so you need change the configurations yourself and manually compile the driver. Method: enter the directory: /usr/local/bin/ztemtApp/zteusbserial, and find the corresponding kernel version of current system. I can see 2.6.27 2.6.28 2.6.29 2.6.30 2.6.31 2.6.32 2.6.33 2.6.34 2.6.35 2.6.36 2.6.37 2.6.38 2.6.39 below2.6.2 in the directory. Which version shall I pick up for installation? Readme file says, we have to do this to insert ztemt.ko in kernel.

    Read the article

  • BizTalk Cross Reference Data Management Strategy

    - by charlie.mott
    Article Source: http://geekswithblogs.net/charliemott This article describes an approach to the management of cross reference data for BizTalk.  Some articles about the BizTalk Cross Referencing features can be found here: http://home.comcast.net/~sdwoodgate/xrefseed.zip http://geekswithblogs.net/michaelstephenson/archive/2006/12/24/101995.aspx http://geekswithblogs.net/charliemott/archive/2009/04/20/value-vs.id-cross-referencing-in-biztalk.aspx Options Current options to managing this data include: Maintaining xml files in the format that can be used by the out-of-the-box BTSXRefImport.exe utility. Use of user interfaces that have been developed to manage this data: BizTalk Cross Referencing Tool XRef XML Creation Tool However, there are the following issues with the above options: The 'BizTalk Cross Referencing Tool' requires a separate database to manage.  The 'XRef XML Creation' tool has no means of persisting the data settings. The 'BizTalk Cross Referencing tool' generates integers in the common id field. I prefer to use a string (e.g. acme.country.uk). This is more readable. (see naming conventions below). Both UI tools continue to use BTSXRefImport.exe.  This utility replaces all xref data. This can be a problem in continuous integration environments that support multiple clients or BizTalk target instances.  If you upload the data for one client it would destroy the data for another client.  Yet in TFS where builds run concurrently, this would break unit tests. Alternative Approach In response to these issues, I instead use simple SQL scripts to directly populate the BizTalkMgmtDb xref tables combined with a data namepacing strategy to isolate client data. Naming Conventions All data keys use namespace prefixing.  The pattern will be <companyName>.<data Type>.  The naming conventions will be to use lower casing for all items.  The data must follow this pattern to isolate it from other company cross-reference data.  The table below shows some sample data. (Note: this data uses the 'ID' cross-reference tables.  the same principles apply for the 'value' cross-referencing tables). Table.Field Description Sample Data xref_AppType.appType Application Types acme.erp acme.portal acme.assetmanagement xref_AppInstance.appInstance Application Instances (each will have a corresponding application type). acme.dynamics.ax acme.dynamics.crm acme.sharepoint acme.maximo xref_IDXRef.idXRef Holds the cross reference data types. acme.taxcode acme.country xref_IDXRefData.CommonID Holds each cross reference type value used by the canonical schemas. acme.vatcode.exmpt acme.vatcode.std acme.country.usa acme.country.uk xref_IDXRefData.AppID This holds the value for each application instance and each xref type. GBP USD SQL Scripts The data to be stored in the BizTalkMgmtDb xref tables will be managed by SQL scripts stored in a database project in the visual studio solution. File(s) Description Build.cmd A sqlcmd script to deploy data by running the SQL scripts below.  (This can be run as part of the MSBuild process).   acme.purgexref.sql SQL script to clear acme.* data from the xref tables.  As such, this will not impact data for any other company. acme.applicationInstances.sql   SQL script to insert application type and application instance data.   acme.vatcode.sql acme.country.sql etc ...  There will be a separate SQL script to insert each cross-reference data type and application specific values for these types.

    Read the article

  • Master Note for Generic Data Warehousing

    - by lajos.varady(at)oracle.com
    ++++++++++++++++++++++++++++++++++++++++++++++++++++ The complete and the most recent version of this article can be viewed from My Oracle Support Knowledge Section. Master Note for Generic Data Warehousing [ID 1269175.1] ++++++++++++++++++++++++++++++++++++++++++++++++++++In this Document   Purpose   Master Note for Generic Data Warehousing      Components covered      Oracle Database Data Warehousing specific documents for recent versions      Technology Network Product Homes      Master Notes available in My Oracle Support      White Papers      Technical Presentations Platforms: 1-914CU; This document is being delivered to you via Oracle Support's Rapid Visibility (RaV) process and therefore has not been subject to an independent technical review. Applies to: Oracle Server - Enterprise Edition - Version: 9.2.0.1 to 11.2.0.2 - Release: 9.2 to 11.2Information in this document applies to any platform. Purpose Provide navigation path Master Note for Generic Data Warehousing Components covered Read Only Materialized ViewsQuery RewriteDatabase Object PartitioningParallel Execution and Parallel QueryDatabase CompressionTransportable TablespacesOracle Online Analytical Processing (OLAP)Oracle Data MiningOracle Database Data Warehousing specific documents for recent versions 11g Release 2 (11.2)11g Release 1 (11.1)10g Release 2 (10.2)10g Release 1 (10.1)9i Release 2 (9.2)9i Release 1 (9.0)Technology Network Product HomesOracle Partitioning Advanced CompressionOracle Data MiningOracle OLAPMaster Notes available in My Oracle SupportThese technical articles have been written by Oracle Support Engineers to provide proactive and top level information and knowledge about the components of thedatabase we handle under the "Database Datawarehousing".Note 1166564.1 Master Note: Transportable Tablespaces (TTS) -- Common Questions and IssuesNote 1087507.1 Master Note for MVIEW 'ORA-' error diagnosis. For Materialized View CREATE or REFRESHNote 1102801.1 Master Note: How to Get a 10046 trace for a Parallel QueryNote 1097154.1 Master Note Parallel Execution Wait Events Note 1107593.1 Master Note for the Oracle OLAP OptionNote 1087643.1 Master Note for Oracle Data MiningNote 1215173.1 Master Note for Query RewriteNote 1223705.1 Master Note for OLTP Compression Note 1269175.1 Master Note for Generic Data WarehousingWhite Papers Transportable Tablespaces white papers Database Upgrade Using Transportable Tablespaces:Oracle Database 11g Release 1 (February 2009) Platform Migration Using Transportable Database Oracle Database 11g and 10g Release 2 (August 2008) Database Upgrade using Transportable Tablespaces: Oracle Database 10g Release 2 (April 2007) Platform Migration using Transportable Tablespaces: Oracle Database 10g Release 2 (April 2007)Parallel Execution and Parallel Query white papers Best Practices for Workload Management of a Data Warehouse on the Sun Oracle Database Machine (June 2010) Effective resource utilization by In-Memory Parallel Execution in Oracle Real Application Clusters 11g Release 2 (Feb 2010) Parallel Execution Fundamentals in Oracle Database 11g Release 2 (November 2009) Parallel Execution with Oracle Database 10g Release 2 (June 2005)Oracle Data Mining white paper Oracle Data Mining 11g Release 2 (March 2010)Partitioning white papers Partitioning with Oracle Database 11g Release 2 (September 2009) Partitioning in Oracle Database 11g (June 2007)Materialized Views and Query Rewrite white papers Oracle Materialized Views  and Query Rewrite (May 2005) Improving Performance using Query Rewrite in Oracle Database 10g (December 2003)Database Compression white papers Advanced Compression with Oracle Database 11g Release 2 (September 2009) Table Compression in Oracle Database 10g Release 2 (May 2005)Oracle OLAP white papers On-line Analytic Processing with Oracle Database 11g Release 2 (September 2009) Using Oracle Business Intelligence Enterprise Edition with the OLAP Option to Oracle Database 11g (July 2008)Generic white papers Enabling Pervasive BI through a Practical Data Warehouse Reference Architecture (February 2010) Optimizing and Protecting Storage with Oracle Database 11g Release 2 (November 2009) Oracle Database 11g for Data Warehousing and Business Intelligence (August 2009) Best practices for a Data Warehouse on Oracle Database 11g (September 2008)Technical PresentationsA selection of ObE - Oracle by Examples documents: Generic Using Basic Database Functionality for Data Warehousing (10g) Partitioning Manipulating Partitions in Oracle Database (11g Release 1) Using High-Speed Data Loading and Rolling Window Operations with Partitioning (11g Release 1) Using Partitioned Outer Join to Fill Gaps in Sparse Data (10g) Materialized View and Query Rewrite Using Materialized Views and Query Rewrite Capabilities (10g) Using the SQLAccess Advisor to Recommend Materialized Views and Indexes (10g) Oracle OLAP Using Microsoft Excel With Oracle 11g Cubes (how to analyze data in Oracle OLAP Cubes using Excel's native capabilities) Using Oracle OLAP 11g With Oracle BI Enterprise Edition (Creating OBIEE Metadata for OLAP 11g Cubes and querying those in BI Answers) Building OLAP 11g Cubes Querying OLAP 11g Cubes Creating Interactive APEX Reports Over OLAP 11g CubesSelection of presentations from the BIWA website:Extreme Data Warehousing With Exadata  by Hermann Baer (July 2010) (slides 2.5MB, recording 54MB)Data Mining Made Easy! Introducing Oracle Data Miner 11g Release 2 New "Work flow" GUI   by Charlie Berger (May 2010) (slides 4.8MB, recording 85MB )Best Practices for Deploying a Data Warehouse on Oracle Database 11g  by Maria Colgan (December 2009)  (slides 3MB, recording 18MB, white paper 3MB )

    Read the article

  • Oracle Enterprise Data Quality: Ever Integration-ready

    - by Mala Narasimharajan
    It is closing in on a year now since Oracle’s acquisition of Datanomic, and the addition of Oracle Enterprise Data Quality (EDQ) to the Oracle software family. The big move has caused some big shifts in emphasis and some very encouraging excitement from the field.  To give an illustration, combined with a shameless promotion of how EDQ can help to give quick insights into your data, I did a quick Phrase Profile of the subject field of emails to the Global EDQ mailing list since it was set up last September. The results revealed a very clear theme:   Integration, Integration, Integration! As well as the important Siebel and Oracle Data Integrator (ODI) integrations, we have been asked about integration with a huge variety of Oracle applications, including EBS, Peoplesoft, CRM on Demand, Fusion, DRM, Endeca, RightNow, and more - and we have not stood still! While it would not have been possible to develop specific pre-integrations with all of the above within a year, we have developed a package of feature-rich out-of-the-box web services and batch processes that can be plugged into any application or middleware technology with ease. And with Siebel, they work out of the box. Oracle Enterprise Data Quality version 9.0.4 includes the Customer Data Services (CDS) pack – a ready set of standard processes with standard interfaces, to provide integrated: Address verification and cleansing  Individual matching Organization matching The services can are suitable for either Batch or Real-Time processing, and are enabled for international data, with simple configuration options driving the set of locale-specific dictionaries that are used. For example, large dictionaries are provided to support international name transcription and variant matching, including highly specialized handling for Arabic, Japanese, Chinese and Korean data. In total across all locales, CDS includes well over a million dictionary entries.   Excerpt from EDQ’s CDS Individual Name Standardization Dictionary CDS has been developed to replace the OEM of Informatica Identity Resolution (IIR) for attached Data Quality on the Oracle price list, but does this in a way that creates a ‘best of both worlds’ situation for customers, who can harness not only the out-of-the-box functionality of pre-packaged matching and standardization services, but also the flexibility of OEDQ if they want to customize the interfaces or the process logic, without having to learn more than one product. From a competitive point of view, we believe this stands us in good stead against our key competitors, including Informatica, who have separate ‘Identity Resolution’ and general DQ products, and IBM, who provide limited out-of-the-box capabilities (with a steep learning curve) in both their QualityStage data quality and Initiate matching products. Here is a brief guide to the main services provided in the pack: Address Verification and Standardization EDQ’s CDS Address Cleaning Process The Address Verification and Standardization service uses EDQ Address Verification (an OEM of Loqate software) to verify and clean addresses in either real-time or batch. The Address Verification processor is wrapped in an EDQ process – this adds significant capabilities over calling the underlying Address Verification API directly, specifically: Country-specific thresholds to determine when to accept the verification result (and therefore to change the input address) based on the confidence level of the API Optimization of address verification by pre-standardizing data where required Formatting of output addresses into the input address fields normally used by applications Adding descriptions of the address verification and geocoding return codes The process can then be used to provide real-time and batch address cleansing in any application; such as a simple web page calling address cleaning and geocoding as part of a check on individual data.     Duplicate Prevention Unlike Informatica Identity Resolution (IIR), EDQ uses stateless services for duplicate prevention to avoid issues caused by complex replication and synchronization of large volume customer data. When a record is added or updated in an application, the EDQ Cluster Key Generation service is called, and returns a number of key values. These are used to select other records (‘candidates’) that may match in the application data (which has been pre-seeded with keys using the same service). The ‘driving record’ (the new or updated record) is then presented along with all selected candidates to the EDQ Matching Service, which decides which of the candidates are a good match with the driving record, and scores them according to the strength of match. In this model, complex multi-locale EDQ techniques can be used to generate the keys and ensure that the right balance between performance and matching effectiveness is maintained, while ensuring that the application retains control of data integrity and transactional commits. The process is explained below: EDQ Duplicate Prevention Architecture Note that where the integration is with a hub, there may be an additional call to the Cluster Key Generation service if the master record has changed due to merges with other records (and therefore needs to have new key values generated before commit). Batch Matching In order to allow customers to use different match rules in batch to real-time, separate matching templates are provided for batch matching. For example, some customers want to minimize intervention in key user flows (such as adding new customers) in front end applications, but to conduct a more exhaustive match on a regular basis in the back office. The batch matching jobs are also used when migrating data between systems, and in this case normally a more precise (and automated) type of matching is required, in order to minimize the review work performed by Data Stewards.  In batch matching, data is captured into EDQ using its standard interfaces, and records are standardized, clustered and matched in an EDQ job before matches are written out. As with all EDQ jobs, batch matching may be called from Oracle Data Integrator (ODI) if required. When working with Siebel CRM (or master data in Siebel UCM), Siebel’s Data Quality Manager is used to instigate batch jobs, and a shared staging database is used to write records for matching and to consume match results. The CDS batch matching processes automatically adjust to Siebel’s ‘Full Match’ (match all records against each other) and ‘Incremental Match’ (match a subset of records against all of their selected candidates) modes. The Future The Customer Data Services Pack is an important part of the Oracle strategy for EDQ, offering a clear path to making Data Quality Assurance an integral part of enterprise applications, and providing a strong value proposition for adopting EDQ. We are planning various additions and improvements, including: An out-of-the-box Data Quality Dashboard Even more comprehensive international data handling Address search (suggesting multiple results) Integrated address matching The EDQ Customer Data Services Pack is part of the Enterprise Data Quality Media Pack, available for download at http://www.oracle.com/technetwork/middleware/oedq/downloads/index.html.

    Read the article

  • MySQL – Introduction to User Defined Variables

    - by Pinal Dave
    MySQL supports user defined variables to have some data that can be used later part of your query. You can save a value to a variable using a SELECT statement and later you can access its value. Unlike other RDBMSs, you do not need to declare the data type for a variable. The data type is automatically assumed when you assign a value. A value can be assigned to a variable using a SET command as shown below SET @server_type:='MySQL'; When you above command is executed, the value, MySQL is assigned to the variable called @server_type. Now you can use this variable in the later part of the code. Suppose if you want to display the value, you can use SELECT statement. SELECT @server_type; The result is MySQL. Once the value is assigned it remains for the entire session until changed by the later statements. So unlike SQL Server, you do not need to have this as part the execution code every time. (Because in SQL Server, the variables are execution scoped and dropped after the execution). You can give column name as below SELECT @server_type AS server_type; You can also SELECT statement to DECLARE and SELECT the values for a variable. SELECT @message:='Welcome to MySQL' AS MESSAGE; The result is Message -------- Welcome to MySQL You can make use of variables to effectively apply many logics. One of the useful method is to generate the row number as shown in this post MySQL – Generating Row Number for Each Row using Variable. Reference: Pinal Dave (http://blog.sqlauthority.com)Filed under: MySQL, PostADay, SQL, SQL Authority, SQL Query, SQL Tips and Tricks, T SQL

    Read the article

  • Master Data Management Implementation Styles

    - by david.butler(at)oracle.com
    In any Master Data Management solution deployment, one of the key decisions to be made is the choice of the MDM architecture. Gartner and other analysts describe some different Hub deployment styles, which must be supported by a best of breed MDM solution in order to guarantee the success of the deployment project.   Registry Style: In a Registry Style MDM Hub, the various source systems publish their data and a subscribing Hub stores only the source system IDs, the Foreign Keys (record IDs on source systems) and the key data values needed for matching. The Hub runs the cleansing and matching algorithms and assigns unique global identifiers to the matched records, but does not send any data back to the source systems. The Registry Style MDM Hub uses data federation capabilities to build the "virtual" golden view of the master entity from the connected systems.   Consolidation Style: The Consolidation Style MDM Hub has a physically instantiated, "golden" record stored in the central Hub. The authoring of the data remains distributed across the spoke systems and the master data can be updated based on events, but is not guaranteed to be up to date. The master data in this case is usually not used for transactions, but rather supports reporting; however, it can also be used for reference operationally.   Coexistence Style: The Coexistence Style MDM Hub involves master data that's authored and stored in numerous spoke systems, but includes a physically instantiated golden record in the central Hub and harmonized master data across the application portfolio. The golden record is constructed in the same manner as in the consolidation style, and, in the operational world, Consolidation Style MDM Hubs often evolve into the Coexistence Style. The key difference is that in this architectural style the master data stored in the central MDM system is selectively published out to the subscribing spoke systems.   Transaction Style: In this architecture, the Hub stores, enhances and maintains all the relevant (master) data attributes. It becomes the authoritative source of truth and publishes this valuable information back to the respective source systems. The Hub publishes and writes back the various data elements to the source systems after the linking, cleansing, matching and enriching algorithms have done their work. Upstream, transactional applications can read master data from the MDM Hub, and, potentially, all spoke systems subscribe to updates published from the central system in a form of harmonization. The Hub needs to support merging of master records. Security and visibility policies at the data attribute level need to be supported by the Transaction Style hub, as well.   Adaptive Transaction Style: This is similar to the Transaction Style, but additionally provides the capability to respond to diverse information and process requests across the enterprise. This style emerged most recently to address the limitations of the above approaches. With the Adaptive Transaction Style, the Hub is built as a platform for consolidating data from disparate third party and internal sources and for serving unified master entity views to operational applications, analytical systems or both. This approach delivers a real-time Hub that has a reliable, persistent foundation of master reference and relationship data, along with all the history and lineage of data changes needed for audit and compliance tracking. On top of this persistent master data foundation, the Hub can dynamically aggregate transaction data on demand from different source systems to deliver the unified golden view to downstream systems. Data can also be accessed through batch interfaces, published to a message bus or served through a real-time services layer. New data sources can be readily added in this approach by extending the data model and by configuring the new source mappings and the survivorship rules, meaning that all legacy data hubs can be leveraged to contribute their records/rules into the new transaction hub. Finally, through rich user interfaces for data stewardship, it allows exception handling by business analysts to keep it current with business rules/practices while maintaining the reliability of best-of-breed master records.   Confederation Style: In this architectural style, several Hubs are maintained at departmental and/or agency and/or territorial level, and each of them are connected to the other Hubs either directly or via a central Super-Hub. Each Domain level Hub can be implemented using any of the previously described styles, but normally the Central Super-Hub is a Registry Style one. This is particularly important for Public Sector organizations, where most of the time it is practically or legally impossible to store in a single central hub all the relevant constituent information from all departments.   Oracle MDM Solutions can be deployed according to any of the above MDM architectural styles, and have been specifically designed to fully support the Transaction and Adaptive Transaction styles. Oracle MDM Solutions provide strong data federation and integration capabilities which are key to enabling the use of the Confederated Hub as a possible architectural style approach. Don't lock yourself into a solution that cannot evolve with your needs. With Oracle's support for any type of deployment architecture, its ability to leverage the outstanding capabilities of the Oracle technology stack, and its open interfaces for non-Oracle technology stacks, Oracle MDM Solutions provide a low TCO and a quick ROI by enabling a phased implementation strategy.

    Read the article

  • How to export and import an user profile from one Quassel core to another?

    - by Zertrin
    I have been using Quassel as my bouncer for IRC for quite a long time now. We (a group of administrators of a small network) have set up a shared Quassel core with many users on the same core. But now I would like to export everything related to my user account from the Quassel database on this core, in order to re-import it later in another Quassel core on my own server. Unfortunately, while a feature for adding users has been implemented into Quassel, nothing is so far provided for either exporting or deleting an user. (if deleting-a-user feature was available, I could have made a copy of the current database, delete all the other users leaving only mine, and use this resulting database on my own server, while leaving the first one untouched on the shared server) Despite extensive research on the Internet on this subject, I've found so far no solution. I have to precise that the backend database for the core has been migrated from the default SQLite backend to a PosgreSQL backend as the database grew sensibly (over 1,5 GB for now). However I'd be glad to hear from any working solution (SQLite or PostgreSQL backend) describing a way to export the data related to a specific user profile and then re-import-it in a new Quasselcore database.

    Read the article

  • How to tackle archived who-is personal data with opt-out?

    - by defaye
    As far as I understand it, it is possible to opt-out (in the UK at least) of having your address details displayed on who-is information of a domain for non-trading individuals. What I want to know is, after opt-out, how do individuals combat archived data? Is there any enforcement of this? How many who-is websites are there which archive data and what rights do we have to force them to remove that data without paying absurd fees? In the case of capitulating to these scoundrels, what point is it in paying for the removal of archived data if that data can presumably resurface on another who-is repository? In other words, what strategy is one supposed to take, besides being wiser after the fact?

    Read the article

  • How to fix type names conflicts in Dynamic Data

    - by SDReyes
    Hi Guys! We're working in a Dynamic Data project that will handle entities coming from two different namespaces: myModel.Abby and myModel.Ben. whose classes are: Abby myModel.Abby.Car myModel.Abby.Lollipop Ben myModel.Ben.Car myModel.Ben.Apple So myModel.Abby.Car and myModel.Ben.Car are homonym. when I try to register both ObjectContext's, an exception is thrown telling us that there are type name conflicts between the mentioned classes (although the types belong to different namespaces). How can we overcome type-name conflicts, caused by repeated type names among different namespaces?

    Read the article

  • javascript arrays and type conversion inconsistencies

    - by ForYourOwnGood
    I have been playing with javascript arrays and I have run into, what I feel, are some inconsistencies, I hope someone can explain them for me. Lets start with this: var myArray = [1, 2, 3, 4, 5]; document.write("Length: " + myArray.length + "<br />"); for( var i in myArray){ document.write( "myArray[" + i + "] = " + myArray[i] + "<br />"); } document.write(myArray.join(", ") + "<br /><br />"); Length: 5 myArray[0] = 1 myArray[1] = 2 myArray[2] = 3 myArray[3] = 4 myArray[4] = 5 1, 2, 3, 4, 5 There is nothing special about this code, but I understand that a javascript array is an object, so properities may be add to the array, the way these properities are added to an array seems inconsistent to me. Before continuing, let me note how string values are to be converted to number values in javascript. Nonempty string - Numeric value of string or NaN Empty string - 0 So since a javascript array is an object the following is legal: myArray["someThing"] = "someThing"; myArray[""] = "Empty String"; myArray["4"] = "four"; for( var i in myArray){ document.write( "myArray[" + i + "] = " + myArray[i] + "<br />"); } document.write(myArray.join(", ") + "<br /><br />"); Length: 5 myArray[0] = 1 myArray[1] = 2 myArray[2] = 3 myArray[3] = 4 myArray[4] = four myArray[someThing] = someThing myArray[] = Empty String 1, 2, 3, 4, four The output is unexpected. The non empty string "4" is converted into its numeric value when setting the property myArray["4"], this seems right. However the empty string "" is not converted into its numeric value, 0, it is treated as an empty string. Also the non empty string "something" is not converted to its numeric value, NaN, it is treated as a string. So which is it? is the statement inside myArray[] in numeric or string context? Also, why are the two, non numeric, properities of myArray not included in myArray.length and myArray.join(", ")?

    Read the article

  • How to force user to user Administrator account in WinForms

    - by Smejda
    I have simple WinForms application where modifying Windows Registry. The problem is that in Vista / Windows 7 I need to force user to switch to administrator. I do not want to force user to Run as Administrator form start of the application. I want him to do it when there is necessity to write to registry. Best case scenario would be to reach exacly the same message which appear in lot's of Setups, when user need to 'switch' to Administrator so there is no necessity to Run as Administrator form beginning. How I can achieve this in .Net ?

    Read the article

  • DataTable C# Empty column type

    - by Dested
    I am trying build a DataTable one row at a time using the following code. foreach (var e in Project.ProjectElements[hi.FakeName].Root.Elements()) { index = 0; object[] obj=new object[count]; foreach (var holdingColumn in names) { string d = e.Attribute(holdingColumn.Key).Value; obj[index++] = d; } dt.Rows.Add(obj); } The problem is the DataTable has types tied to the columns. Sometimes im passing null (or an empty string) in that object index and it is telling me that it cant be converted properly to a DateTime (in this case). My question is what should I default this value to, or is there some way to have the DataTable ignore empty values.

    Read the article

  • How do I set default values on new properties for existing entities after light weight core data migration?

    - by Moritz
    I've successfully completed light weight migration on my core data model. My custom entity Vehicle received a new property 'tirePressure' which is an optional property of type double with the default value 0.00. When 'old' Vehicles are fetched from the store (Vehicles that were created before the migration took place) the value for their 'tirePressure' property is nil. (Is that expected behavior?) So I thought: "No problem, I'll just do this in the Vehicle class:" - (void)awakeFromFetch { [super awakeFromFetch]; if (nil == self.tirePressure) { [self willChangeValueForKey:@"tirePressure"]; self.tirePressure = [NSNumber numberWithDouble:0.0]; [self didChangeValueForKey:@"tirePressure"]; } } Since "change processing is explicitly disabled around" awakeFromFetch I thought the calls to willChangeValueForKey and didChangeValueForKey would mark 'tirePresure' as dirty. But they don't. Every time these Vehicles are fetched from the store 'tirePressure' continues to be nil despite having saved the context.

    Read the article

  • wanna store Object in MySQL database

    - by kandarp
    I have a variable in java which return type is Object(java.lang.Object). I want to store this variable value in MySQL database without casting in any other primitive data type. Is there any data type available in MySQL related to Object? If anybody knows, please reply at your earliest time. Thanks,

    Read the article

  • Returning superclass of return type from remote EJB method

    - by fish
    Let's say I have remote interface A: @Remote public interface A { public Response doSomething(); } And implementation: @Stateless public class B implements A { public BeeResponse doSomething() {...} } Where: BeeResponse extends Response. Response is located in the EJB-API jar and BeeResponse is in the implementation jar. Response and BeeResponse have different serialVersionUID. My assumption is that the unmarshalling of the response from B will fail, am I correct?

    Read the article

  • Designing constructors around type erasure in Java

    - by Internet Friend
    Yesterday, I was designing a Java class which I wanted to be initalized with Lists of various generic types: TheClass(List<String> list) { ... } TheClass(List<OtherType> list) { ... } This will not compile, as the constructors have the same erasure. I just went with factory methods differentiated by their names instead: public static TheClass createWithStrings(List<String> list) public static TheClass createWithOtherTypes(List<OtherType> list) This is less than optimal, as there isn't a single obvious location where all the different options for creating instances are available. I tried to search for better design ideas, but found surprisingly few results. What other patterns exist for designing around this problem?

    Read the article

  • How do you encourage users to fill out their profile?

    - by mattdell
    Hello, I wanted to open up the topic to discuss ways to encourage or incentivize users to fill in information in a user profile on a website, such as skills, location, organization, etc. More information in a user profile can give a website an improved capability for its users to search, network, and collaborate. Without bugging users to fill in their profiles (ie - via annoying e-mail reminders), what other ways have you guys come up with to encourage user input? Best, -Matt

    Read the article

  • User controls in masterpage and anonymous user

    - by Senad Uka
    I am developing a master page which includes the user control that generates a menu from the list with a specific logic. Before including the control into master page I successfully configured anonymous access to the site. After including the control and deploying - site prompts for user name and password. I allowed the anonymous access to the list. Oh yes ... It worked on SHarepoint 2010 beta, but the problem happens when deploying to the Sharepoint 2010 final release. Additional data: I am using Sharepoint Server 2010 with Standard features, standalone instalation on Windows Server 2008 R2 for deployment, and Visual Studio 2010 Ultimate for development of masterpage and user control.

    Read the article

< Previous Page | 52 53 54 55 56 57 58 59 60 61 62 63  | Next Page >