Search Results

Search found 16794 results on 672 pages for 'memory usage'.

Page 565/672 | < Previous Page | 561 562 563 564 565 566 567 568 569 570 571 572  | Next Page >

  • RAID administration in Debian Lenny

    - by Siim K
    I've got an old box that I don't want to scrap yet because it's got a nice working 5-disk RAID assembly. I want to create 2 arrays: RAID 1 with 2 disks and RAID 5 with the other 3 disks. The RAID card is Intel SRCU31L. I can create the RAID 1 volume in the console that you access with Ctrl+C at startup. But it only allows for creation of one volume so I can't do anything with the 3 remaining disks. I installed Debian Lenny on the RAID 1 volume and it worked out nicely. What utilites could I now use to create/manage the RAID volumes in Debian Linux? I installed the raidutils package but get an error when trying to fetch a list: #raidutil -L controller or #raidutil -L physical # raidutil -L controller osdOpenEngine : 11/08/110-18:16:08 Fatal error, no active controller device files found. Engine connect failed: Open What could I try to get this thing working? Can you suggest any other tools? Command #lspci -vv gives me this about the controller: 00:06.1 I2O: Intel Corporation Integrated RAID (rev 02) (prog-if 01) Subsystem: Intel Corporation Device 0001 Control: I/O- Mem+ BusMaster+ SpecCycle- MemWINV+ VGASnoop- ParErr- Step ping- SERR+ FastB2B- DisINTx- Status: Cap+ 66MHz- UDF- FastB2B+ ParErr- DEVSEL=medium >TAbort- <TAbort - <MAbort- >SERR- <PERR- INTx- Latency: 64, Cache Line Size: 32 bytes Interrupt: pin A routed to IRQ 26 Region 0: Memory at f9800000 (32-bit, prefetchable) [size=8M] [virtual] Expansion ROM at 30020000 [disabled] [size=64K] Capabilities: <access denied> Kernel driver in use: PCI_I2O Kernel modules: i2o_core

    Read the article

  • install zenoss on ubuntu, raise No valid ZENHOME error

    - by bxshi
    I've added an user with name zenoss, and set export ZENHOME=/usr/local/zenoss in ~/.bashrc under /home/zenoss, and when using echo $ZENHOME, it could show /usr/local/zenoss When install zenoss, I switched to zenoss and then run install.sh under zenoss-4.2.0/inst, when it tries to run Tests, the error occured. ------------------------------------------------------- T E S T S ------------------------------------------------------- Running org.zenoss.utils.ZenPacksTest Tests run: 3, Failures: 0, Errors: 3, Skipped: 0, Time elapsed: 0.045 sec <<< FAILURE! Running org.zenoss.utils.ZenossTest Tests run: 3, Failures: 0, Errors: 0, Skipped: 0, Time elapsed: 0.71 sec Results : Tests in error: testGetZenPack(org.zenoss.utils.ZenPacksTest): No valid ZENHOME could be found. testGetPackPath(org.zenoss.utils.ZenPacksTest): No valid ZENHOME could be found. testGetAllPacks(org.zenoss.utils.ZenPacksTest): No valid ZENHOME could be found. Tests run: 6, Failures: 0, Errors: 3, Skipped: 0 [INFO] ------------------------------------------------------------------------ [INFO] Reactor Summary: [INFO] [INFO] Zenoss Core ....................................... SUCCESS [27.643s] [INFO] Zenoss Core Utilities ............................. FAILURE [12.742s] [INFO] Zenoss Jython Distribution ........................ SKIPPED [INFO] ------------------------------------------------------------------------ [INFO] BUILD FAILURE [INFO] ------------------------------------------------------------------------ [INFO] Total time: 40.586s [INFO] Finished at: Wed Sep 26 15:39:24 CST 2012 [INFO] Final Memory: 16M/60M [INFO] ------------------------------------------------------------------------ [ERROR] Failed to execute goal org.apache.maven.plugins:maven-surefire-plugin:2.8:test (default-test) on project utils: There are test failures. [ERROR] [ERROR] Please refer to /home/zenoss/zenoss-4.2.0/inst/build/java/java/zenoss-utils/target/surefire-reports for the individual test results.

    Read the article

  • Computer won't go into standby

    - by Robert
    When I select Start-Turn off computer-Standby the 'turn off computer' option window closes, and then nothing else happens. I can start new applications, and Windows acts like I never selected standby. I ran it for several hours after that. If I have a TV program scheduled to record when I select standby I get a window (the Pinnacle TV software) asking if I'm sure, there are programs scheduled to record - and the computer just keeps running after I select yes, never going into standby. I added that detail as it shows the standby process is starting. [This problem also happens if a TV program is not scheduled, so the scheduler task in not running/in memory. This problem happens regardless of whether I'm not watching TV. This problem happens regardless of whether Media Center is running (it usually isn't, I'm using Pinnacle to watch TV).] I looked at "How to troubleshoot hibernation and standby issues in Windows XP" http://support.microsoft.com/kb/907477 - ACPI is enabled, and "standby" is an option in "Power Options Properties." So it appears to be setup correctly. Windows XP SP3 Media Center Edition, all current updates installed.

    Read the article

  • What could cause TFTP reloaded Cisco `running-config` on 871 to fail?

    - by xtian
    Cisco CCP Write Configuration borked my 871w config while I was trying to setup port forwarding. I went through the basic steps to reconfig the router. I looked to see if I could just reset the router. Nope. I tested the 871's flash memory with fsck to see if there was hardware failure. Nope. Then I rewrote the minimal config for TFTP (which is the same for Cisco's CCP app.). Thne, I successfully uploaded a previously working running-config from Win Vista using SolarWinds TFTP Server, unfortunately the restore was not entirely successful. The old running config was saved to the 871's startup-config and I can login using console port. Some other things that are working are the hostname and welcome message but that's about it. Startup shows an error SETUP: new interface NVI0 placed in "shutdown" state after tftp. The missing light on the access point modem for ethernet link show the 871'a outside FE4 is not working. SO...what's the possible problem with reloading a previously working config (approximately 4 months with the same config) via TFTP? Is there something I can look for on the 871 to verify the config? Or on Vista to validate the config file itself before I transfer it? Or, is this there a common TFTP issue? UPDATE. I missed the instruction from Cisco's TFTP page to delete aaa lines from the config (although a video from a SuperUser user didn't make this point in his most excellent demo). There were several lines of this sort, I deleted them and uploaded again. However, they're back. I assume they're added automatically? [nope, see answer] UPDATE 2. The reload of previous settings was successful, but this error remains. I don't even know now if it was there before or not. It seems irrelevant to the question.

    Read the article

  • Per connection bandwidth limit

    - by Kyr
    Apparently, our server box running Windows Server 2008 R2 has a per connection bandwidth limit of 0.2 MB/s. Meaning, while one TCP connection can pull at max 0.2 MB/s, 60 parallel connections can pull 12 MB/s. We first noticed this when trying to checkout large SVN repository from this server. I used a simple Java application to test this, transferring data from server to workstation using variable number of threads (one connection per thread). Server part of the application simply writes 1 MB memory buffer to socket 100 times, so there is no disk involvement. Each connection topped at 0.2 MB/s. Same per connection limit was for only one as was for 60 parallel connections. The problem is that I have no idea from where this limit comes from. I have very little experience administrating Windows Server, so I was mostly trying to find something by googling. I have checked the following: Local Computer Policy QoS Packet Scheduler Limit reservable bandwidth: it's Not configured; Group Policy Management Console: we have two GOPs, but neiher has any Policy-based QoS defined; There isn't any bandwidth limiter program installed, as far as I can tell. We're using standard Windows Firewall. I can update this question with any additional information if needed.

    Read the article

  • How come my Intel 520 180GB SSD performs extremely poorly?

    - by Willem
    I recently installed a new Intel 520 series 180GB SSD in my brand new MacBook Pro. The system is as follows: Model: MacBook Pro 15-inch, Late 2011 (MacBookPro8,2) Processor: 2.4 GHz Intel Core i7 Memory: 16 GB 1333 MHz DDR3 Graphics: AMD Radeon HD 6770M 1024 MB Software: Mac OS X Lion 10.7.3 Main Drive Bay: Intel 520-series 180GB SATA-3 (6GB/s negotiated link) SSD (Firmware: 400i) [80GB free] Optical Bay: Toshiba 5400 RPM 750GB SATA-2 HDD Trim: Enabled (according to Trim Enabler App) And here are the speeds I'm getting: Read: 412 MB/s Write: 186 MB/s What have I done wrong? Results expected: Read/write both 500MB/s I have seen benchmarks with lesser SSD:s (SATA-2 even) outperform my write-speeds by far. Also, Intel 520 SSD:s are supposed to be the top class of SSD:s. Trim Enabler report: This looks a bit odd compared to screenshots from their site: These is the defined S.M.A.R.T attributes (taken from Intel): And here are my S.M.A.R.T attributes read using smartctl tool from smartmontools: They don't seem very compatible. I'm going to try and look for a S.M.A.R.T attributes reader tool for OS X which might support Intel 520 series.

    Read the article

  • Server nearly unusable when doing disk writes

    - by Wikser
    My question closely relates to my last question here on serverfault. I was copying about 5GB from a 10 year old desktop computer to the server. The copy was done in Windows Explorer. In this situation I would assume the server to be bored by the dataflow. But as usual with this server, it really slowed down. At least I could work with the remote session, even there was some serious latency. The copy took its time (20min?). In this time I went to a colleague and he tried to log in in the same server via remote desktop (for some other reason). It took about a minute to get to the login screen, a minute to open the control panel, a minute to open the performance monitor, ... Icons were loading maybe one per second. We saw the following (from memory): CPU: 2% Avg. Queue Length: 50 Pages/sec: 115 (?) There was no other considerable activity on the server. The server seldom serves some ASP.NET pages, which became also very slow in this time. The relevant configuration is as follows: Windows 2003 SEAGATE ST3500631NS (7200 rpm, 500 GB) LSI MegaRAID based RAID 5 4 disks, 1 hot spare Write Through No read-ahead Direct Cache Mode Harddisk-Cache-Mode: off Is this normal behaviour for such a configuration? What measurements could give further clues? Is it reasonable to reduce the priority of such copy I/O and favour other processes like the remote desktop? How would you do that? Many thanks!

    Read the article

  • Diagnosing Microsoft SQL Server error 9001: The log for the database is not available.

    - by Scott Mitchell
    Over the weekend a website I run stopped functioning, recording the following error in the Event Viewer each time a request is made to the website: Event ID: 9001 The log for database 'database name' is not available. Check the event log for related error messages. Resolve any errors and restart the database. The website is hosted on a dedicated server, so I am able to RDP into the server and poke around. The LDF file for the database exists in the C:\Program Files\Microsoft SQL Server\MSSQL10.MSSQLSERVER\MSSQL\DATA folder, but attempting to do any work with the database from Management Studio results in a dialog box reporting the same error - 9001: The log for database is not available... This is the first time I've received this error, and I've been hosting this site (and others) on this dedicated web server for over two years now. It is my understanding that this error indicates a corrupt log file. I was able to get the website back online by Detaching the database and then restoring a backup from a couple days ago, but my concern is that this error is indicative of a more sinister problem, namely a hard drive failure. I emailed support at the web hosting company and this was their reply: There doesn't appear to be any other indications of the cause in the Event Log, so it's possible that the log was corrupted. Currently the memory's resources is at 87%, which also may have an impact but is unlikely. Can the log just "become corrupted?" My question: What are the next steps I should take to diagnose this problem? How can I determine if this is, indeed, a hardware problem? And if it is, are there any options beyond replacing the disk? Thanks

    Read the article

  • Lenovo S10 Ideapad will not boot while original hard drive is installed, neither from hard drive or

    - by aki
    Hello, first time posting here so I'll try to be very clear. I have a Lenovo S10 Ideapad netbook which fails to boot to an OS. It shows the Lenovo splash screen and can get to the BIOS but it doesn't get to GRUB (was dual booting Ubuntu 9.10 and Win 7, was working fine for months, ie this isn't a new dual boot gone bad). After the splash screen it displays a flashing cursor in the upper left corner. Power cycled to no avail. Here is what I have done trying to narrow the problem down: The machine will boot to Ubuntu using an install/live USB drive, but only if ANOTHER hard drive is installed or NO hard drive is installed. The boot order always lists USB first. Also, there is a 2 gb RAM upgrade but I think that's fine; the Ubuntu USB drive boots fine with it, and "free" sees the whole 2gb of memory. So it seems like the hard drive is bad. I was able to put the bad drive in a different laptop and mount it to recover files. I'm ready to replace the bad hard drive, but I would like to know if this situation makes any sense. If the hard drive is bad, shouldn't I still be able to boot with the Ubuntu USB drive while the bad drive is installed? I would have expected the machine to boot into Ubuntu anyway even if with a bad drive, since the boot order lists USB first. But it seems that when the bad drive is installed, the machine ignores the USB drive and hangs with the flashing cursor. Thanks for any ideas! Sorry for the long post, I just want to put all the info I have up front! Basically I'm going to buy a new drive, but I am mostly curious if this is a typical or at least not unusual situation.

    Read the article

  • Windows 7 task bar stuck in hiding, how to fix?

    - by Rainer Blome
    In Windows 7, I use the "Auto-hide the task bar" feature. Usually, it works fine: As soon as the pointer touches the screen bottom, the task bar pops up. However sometimes, it refuses to rise. Pressing the "Windows" key (or Ctrl-ESC) makes the start menu appear, forcing the task bar from hinding as well. Once I've done this, the task-bar auto-rises again. This is annoying, it interrupts flow. Has anyone else noticed this? How do I avoid this? Searching for "Windows 7 task bar auto-raise" shows that at least one other person experienced this problem: http://answers.microsoft.com/en-us/windows/forum/windows_7-desktop/how-can-i-fix-the-taskbars-auto-hide/8cdf6369-7354-4d29-9249-b7096ed0e28b?msgId=6dac3361-9d0f-4a9e-8642-b91a72826ba4 To answer the question posed by the "helpful" support engineer on the above page, of course I am running some apps when this happens, usually Explorer, Firefox, Eclipse, Cygwin/X, Xterm, Emacs, Notes, VPN client, Firewall. If my memory serves correctly, I have seen this behavior on earlier versions of Windows as well, XP at least. To reproduce this behavior, I tried switching between apps, and bringing apps to open other windows. I am unable to reproduce this behavior so far. So far, it appears to happen out of the blue, sometimes multiple times a day. Looks like a bug to me. The task bar should raise no matter what.

    Read the article

  • Redis as substitution for Memcache

    - by Boban P.
    We have distributed web app, and for now, as session handler, we use two separate instances of memcache in redundancy, so everything that is written in one memcache is also written in other. Memcache is fairly easy to install, use, and maintain but we have one problem: if one memcache fail, everything is fine, php comunicate with other instance which has all data (although, half of connections have a delay because they try to use failed one, wait a little, and then contact other memcache). When failed instance comes back to life again, it starts up empty. If established session request data from that instance, session fails, and user logs out, and that happens to half of users.So, we are thinking about to switch to redis for session handling, and maybe keep memcache for cache only. My questions are: If we setup redis instances as master-slave, and if master fails, can sentinel promote slave as new master and when old master comes back to life, will it stay as slave or not? Is redis call malloc at startup to allocate part of memory, like memcache or varnish, or it calls malloc for every key inserted? And what are pros and cons of that?

    Read the article

  • Computer hangs at boot screen with new RAID card

    - by shanethehat
    I am trying to build a new server around a Biostar TH61 motherboard and an Adaptec 6405E RAID controller card. The machine booted fine from USB before the RAID card and drives were installed. After installing, on the first boot the card was detected, but then started to spit out the following message every 10 seconds: Error: Controller Kernel Stopped Running << Press any key to continue ... Following the troubleshooting guide I unplugged everything, reseated the card, and reattached all the drives. This time the machine is sitting on the boot screen without any error messages and flashing a cursor, but after 15 minutes of this, nothing seems to be happening. Given that there are no error messages I'm hesitant to reboot again. Is it normal for a RAID card to sit without a status message when it firsts boots, maybe to initialise the drives or something? The current screen output looks a bit like this: Controller #00 found at PCI Slot:01, Bus:01, Dev:00, Func:00 Controller Model: Adaptec 6405E Firmware Version: 5.2-0[18512] Memory Size: 128MB Serial number: 111111111111111 SAS WWN: 50000D1104AE9180 _ Update: So after waiting 30 minutes I've rebooted back to the Kernal Stopped Running error. Maybe time to update the RAID BIOS.

    Read the article

  • Xen domain migration locking problem

    - by brodie
    I am trying to live migrate a VM (domain) between two Xen servers. I have xen locking (xend-domain-lock = yes) configured with a ocfs2 shared storage between them. This locking is working fine. If I try to start up the VM on the secondary server it refuses to start (which is correct). The problem I am having is when trying to do live migration, it seems like it is trying to remove the lock twice. The first lock it removes is for "domain test", the second is for "migrating-test" which does not exist. Should their be a lock for this "migrating-test" VM? These are the relevant options in the xen config file: (xend-relocation-server yes) (xend-relocation-port 8002) (xend-relocation-address '') (xend-relocation-hosts-allow '') (xend-domain-lock yes) (xend-domain-lock-path /var/lib/xen/lock) This is the section of the log: [2010-06-10 10:45:57 14488] DEBUG (XendDomainInfo:4054) Releasing lock for domain test [2010-06-10 10:45:57 14488] INFO (XendCheckpoint:474) SUSPEND shinfo 000c6ceb [2010-06-10 10:45:57 14488] INFO (XendCheckpoint:474) delta 21ms, dom0 95%, target 0%, sent 57Mb/s, dirtied 173Mb/s 111 pages 4: sent 111, skipped 0, delta 6ms, dom0 100%, target 0%, sent 606Mb/s, dirtied 606Mb/s 111 pages [2010-06-10 10:45:57 14488] INFO (XendCheckpoint:474) Total pages sent= 131295 (0.99x) [2010-06-10 10:45:57 14488] INFO (XendCheckpoint:474) (of which 0 were fixups) [2010-06-10 10:45:57 14488] INFO (XendCheckpoint:474) All memory is saved [2010-06-10 10:45:57 14488] INFO (XendCheckpoint:474) Save exit rc=0 [2010-06-10 10:45:57 14488] INFO (XendCheckpoint:123) Domain 22 suspended. [2010-06-10 10:45:57 14488] DEBUG (XendDomainInfo:2757) XendDomainInfo.destroy: domid=22 [2010-06-10 10:45:58 14488] DEBUG (XendDomainInfo:2227) Destroying device model [2010-06-10 10:45:58 14488] INFO (image:567) migrating-test device model terminated [2010-06-10 10:45:58 14488] DEBUG (XendDomainInfo:2234) Releasing devices [2010-06-10 10:45:58 14488] DEBUG (XendDomainInfo:2247) Removing vif/0 [2010-06-10 10:45:58 14488] DEBUG (XendDomainInfo:1137) XendDomainInfo.destroyDevice: deviceClass = vif, device = vif/0 [2010-06-10 10:45:58 14488] DEBUG (XendDomainInfo:2247) Removing vkbd/0 [2010-06-10 10:45:58 14488] DEBUG (XendDomainInfo:1137) XendDomainInfo.destroyDevice: deviceClass = vkbd, device = vkbd/0 [2010-06-10 10:45:58 14488] DEBUG (XendDomainInfo:2247) Removing console/0 [2010-06-10 10:45:58 14488] DEBUG (XendDomainInfo:1137) XendDomainInfo.destroyDevice: deviceClass = console, device = console/0 [2010-06-10 10:45:58 14488] DEBUG (XendDomainInfo:2247) Removing vbd/51712 [2010-06-10 10:45:58 14488] DEBUG (XendDomainInfo:1137) XendDomainInfo.destroyDevice: deviceClass = vbd, device = vbd/51712 [2010-06-10 10:45:58 14488] DEBUG (XendDomainInfo:2247) Removing vfb/0 [2010-06-10 10:45:58 14488] DEBUG (XendDomainInfo:1137) XendDomainInfo.destroyDevice: deviceClass = vfb, device = vfb/0 [2010-06-10 10:45:58 14488] DEBUG (XendDomainInfo:4054) Releasing lock for domain migrating-test [2010-06-10 10:45:59 14488] ERROR (XendDomainInfo:4070) Failed to remove unmanaged directory /var/lib/xen/lock/b01515ae-9173-03cb-0cb7-06f3dfbede8b.

    Read the article

  • Looking for comprehensive computer monitoring software

    - by cornjuliox
    Summer in this country is insanely hot. So hot in fact, that I think we just lost a machine due to overheating (last recorded CPU/GPU temp was close to 100 C, now it wont start and lets out a long series of short beeps on power up), but that's not my concern here. Since heat is such a problem for me, I use several different pieces of software to monitor temperatures in my machine. I use MSI Afterburner to monitor GPU temp, control GPU fan speed and for some light overclocking, and then I use Speccy and SpeedFan to monitor the rest of the system, CPU temp and everything. The setup works fine for now, but I want to consolidate all this into one program so I'm not juggling several windows at once. Is there any program out there that will let me monitor the following from a single window: CPU Temp and Fan Speed CPU clock GPU Temp and Fan Speed GPU clock, both core and memory Additionally, mobo temp (Speccy lists both CPU and Motherboard temp, I assume that the latter is referring to North and Southbridge temperatures. I'm also looking for the ability to chart these data points on a graph over time, basically to see just how high the temperatures spike under load and for general analysis. It'd be nice if it could handle overclocking of both CPU and GPU in real time too. Any suggestions? Edit: I forgot to mention that I'm on Windows 7, 64-bit

    Read the article

  • Are These Parts compatible?

    - by ell
    I have never assembled a PC before, although I have taken an old one apart and replaced a few parts in others here and there so I have (very) limited experience. I have been looking to make a pc and here are the parts I might buy: Foxconn P45AL Intel P45 (Socket 775) DDR2 Motherboard (with onboard sound I believe) Gigabyte GeForce GTX 460 OC 768MB GDDR5 PCI-Express Graphics Card Already have 2 1gb sticks of dual channel DDR2 memory Intel Core 2 Quad Q8400 LGA775 'Yorkfield' 2.66GHz 4MB-cache Processor Samsung SpinPoint F3 1TB SATA-II 32MB Cache Hard Drive Antec Dark Fleet Series DF10 Gaming Enclosure – Black I already have monitor, mouse, keyboard and DVD/CD drive Akasa Freedom Power 1000W Modular Power Supply I have never done this before so feel free to laugh at me for getting something obvious wrong, forgetting a vital component etc. but is all of this compatible? And have I gone overkill on the PSU, if so, please recommend one. Thanks in advance, ell. EDIT: Added PSU which I forgot to mention EDIT: I would be using this to surf the internet, write e-mails, chat, word process, play games such as team fortress 2 & spring rts (at highest graphics hopefully), some 3d modelling in blender, some opengl programming, and image editing in GIMP.

    Read the article

  • Can you transfer a Windows 7 XP-mode VHD to a new PC without the need for reactivation?

    - by Henk
    Hi. At the moment I am running Vista 32 bit and use VPC 2007 a lot. I have several W2000 VMs set up with complex software configurations. For me, one of the advantages of working with VPCs is that a VM can easily be copied to another PC (like a notebook). Also, when I move to a new PC, I can immediately work with my existing VMs without the need to reinstall all applications. I am thinking about buying a new pc with Windows 7 64 bit pro, and using the xp-mode VM that comes with Windows 7. The advantages would be support for more memory (so being able to run more VM's simultaneously) and having a licenced XP VM. I would like to know if you can transfer a VHD that is based on the xp-mode VHD to another machine without Activation issues. The other machine will of course, also be running W7. I would guess that this would not be a problem. However, I did read about a guy who had to reinstall his W7 because of a harddisk failure, and could not access his xp-mode VHD anymore because it demanded re-activation. Thanks. Henk.

    Read the article

  • SQL Server 2008 Bring Database Online trying to open a file from a drive that doesn't exist

    - by Nai
    This is my error I am facing TITLE: Microsoft.SqlServer.Smo Set offline failed for Database 'Go3D_Retailer ------------------------------ ADDITIONAL INFORMATION: An exception occurred while executing a Transact-SQL statement or batch. (Microsoft.SqlServer.ConnectionInfo) Unable to open the physical file "E:\Program Files\Microsoft SQL Server\MSSQL10.MSSQLSERVER\MSSQL\DATA\ftrow_Go3D_catalog.ndf". Operating system error 2: "2(failed to retrieve text for this error. Reason: 15105)". Database 'Go3D_Retailer' cannot be opened due to inaccessible files or insufficient memory or disk space. See the SQL Server errorlog for details. ALTER DATABASE statement failed. (Microsoft SQL Server, Error: 5120) Background to this error I've been trying to move my destination logshipping database to another physical server for analysis purposes. Because I do not have domain keys and active directory set up, I had to hack my process by using the same username/password for both the source and destination servers to get the process to work. Following that, I used this guy's solution to move the destination database to another server. However, this error occurs when I try to bring the database back online. I don't have an E drive on my server and I have no idea why it's trying to open a file from E drive. I have over a 100gb left on my hard disk so it's definitely not a space issue. This sounds like a bug... Any ideas?

    Read the article

  • MAMP MySQL won't start

    - by Tony
    I uninstalled MAMP completely, downloaded fresh copy of MAMP 2 from the MAMP website, did a clean install. However, when I try to start mysql, I get the following error log 111120 21:37:49 mysqld_safe Starting mysqld daemon with databases from /Applications/MAMP/db/mysql 111120 21:37:50 [Warning] You have forced lower_case_table_names to 0 through a command-line option, even though your file system '/Applications/MAMP/db/mysql/' is case insensitive. This means that you can corrupt a MyISAM table by accessing it with different cases. You should consider changing lower_case_table_names to 1 or 2 111120 21:37:50 [Note] Plugin 'FEDERATED' is disabled. 111120 21:37:50 InnoDB: The InnoDB memory heap is disabled 111120 21:37:50 InnoDB: Mutexes and rw_locks use GCC atomic builtins 111120 21:37:50 InnoDB: Compressed tables use zlib 1.2.3 111120 21:37:50 InnoDB: Initializing buffer pool, size = 128.0M 111120 21:37:50 InnoDB: Completed initialization of buffer pool 111120 21:37:50 InnoDB: highest supported file format is Barracuda. 111120 21:37:50 InnoDB: Waiting for the background threads to start 111120 21:37:51 InnoDB: 1.1.5 started; log sequence number 1595675 111120 21:37:51 [ERROR] /Applications/MAMP/Library/bin/mysqld: unknown option '--skip-locking' 111120 21:37:51 [ERROR] Aborting 111120 21:37:51 InnoDB: Starting shutdown... 111120 21:37:51 InnoDB: Shutdown completed; log sequence number 1595675 111120 21:37:51 [Note] /Applications/MAMP/Library/bin/mysqld: Shutdown complete 111120 21:37:51 mysqld_safe mysqld from pid file /Applications/MAMP/tmp/mysql/mysql.pid ended I've no clue why this is happening. I googled around and made sure that no instance of MySQL is running. Nothing seems to help.

    Read the article

  • No apparent reason for high load average

    - by Oz.
    We have several web servers running on Amazon (ec2) c1.xlarge, over Amazon AMI. The servers are duplicates of each other, running the exact same hardware and software. Each server spec is: 7 GB of memory 20 EC2 Compute Units (8 virtual cores with 2.5 EC2 Compute Units each) 1690 GB of instance storage 64-bit platform I/O Performance: High API name: c1.xlarge A couple of weeks ago we have run a yum upgrade on one of the servers. Starting on this upgrade the upgraded server started showing a high load average. Needless to say, we did not update the other servers and we can not do so until we understand the reason for this behavior. The strange thing is that when we compare the servers using top or iostat, we can not find the reason for the high load. Note that we have moved traffic from the "problematic" server to the others, which have made the "problematic" server less crowded in terms of requests, and still his load is higher. Do you have any idea what could it be, or where else can we check? Many thanks for the help! Oz. # # proper server # w command # 00:42:26 up 2 days, 19:54, 2 users, load average: 0.41, 0.48, 0.49 USER TTY FROM LOGIN@ IDLE JCPU PCPU WHAT pts/1 82.80.137.29 00:28 14:05 0.01s 0.01s -bash pts/2 82.80.137.29 00:38 0.00s 0.02s 0.00s w # # proper server # iostat command # Linux 3.2.12-3.2.4.amzn1.x86_64 _x86_64_ (8 CPU) avg-cpu: %user %nice %system %iowait %steal %idle 9.03 0.02 4.26 0.17 0.13 86.39 Device: tps Blk_read/s Blk_wrtn/s Blk_read Blk_wrtn xvdap1 1.63 1.50 55.00 367236 13444008 xvdfp1 4.41 45.93 70.48 11227226 17228552 xvdfp2 2.61 2.01 59.81 491890 14620104 xvdfp3 8.16 14.47 94.23 3536522 23034376 xvdfp4 0.98 0.79 45.86 192818 11209784 # # problematic server # w command # 00:43:26 up 2 days, 21:52, 2 users, load average: 1.35, 1.10, 1.17 USER TTY FROM LOGIN@ IDLE JCPU PCPU WHAT pts/0 82.80.137.29 00:28 15:04 0.02s 0.02s -bash pts/1 82.80.137.29 00:38 0.00s 0.05s 0.00s w # # problematic server # iostat command # Linux 3.2.20-1.29.6.amzn1.x86_64 _x86_64_ (8 CPU) avg-cpu: %user %nice %system %iowait %steal %idle 7.97 0.04 3.43 0.19 0.07 88.30 Device: tps Blk_read/s Blk_wrtn/s Blk_read Blk_wrtn xvdap1 2.10 1.49 76.54 374660 19253592 xvdfp1 5.64 40.98 85.92 10308946 21612112 xvdfp2 3.97 4.32 93.18 1087090 23439488 xvdfp3 10.87 30.30 115.14 7622474 28961720 xvdfp4 1.12 0.28 65.54 71034 16487112

    Read the article

  • Dell R320 RAID 10 with CacheCade

    - by Geekman
    I'm looking for a higher-performance build for our 1RU Dell R320 servers, in terms of IOPS. Right now I'm fairly settled on: 4 x 600 GB 3.5" 15K RPM SAS RAID 1+0 array This should give good performance, but if possible, I want to also add an SSD Cache into the mix, but I'm not sure if there's enough room? According to the tech-specs, there's only up to 4 total 3.5" drive bays available. Is there any way to fit at least a single SSD drive along-side the 4x3.5" drives? I was hoping there's a special spot to put the cache SSD drive (though from memory, I doubt there'd be room). Or am I right in thinking that the cache drives are simply drives plugged in "normally" just as any other drive, but are nominated as CacheCade drives in the PERC controller? Are there any options for having the 4x600GB RAID 10 array, and the SSD cache drive, too? Based on the tech-specs (with up to 8x2.5" drives), maybe I need to use 2.5" SAS drives, leaving another 4 bays spare, plenty of room for the SSD cache drive. Has anyone achieved this using 3.5" drives, somehow?

    Read the article

  • Tomcat6 getting crashed at regular intervals installed in Ubuntu

    - by Milesh Rout
    I have installed Tomcat6 in Ubuntu OS and when I run my web application the server gets crashed at regular intervals. I have tried a lot but not getting the solution. I have increased the memory upto 2048mb but still getting such error. Following is the error I am getting. Any help would be really appreciated. org.apache.tomcat.util.http.Parameters processParametersINFO: Invalid chunk starting at byte [312] and ending at byte [312] with a value of [null] ignoredException in thread "Timer-1" Exception in thread "com.mchange.v2.async.ThreadPoolAsynchronousRunner$PoolThread-#0" Exception in thread "com.mchange.v2.async.ThreadPoolAsynchronousRunner$PoolThread-#2" Exception in thread "com.mchange.v2.async.ThreadPoolAsynchronousRunner$PoolThread-#1" Exception in thread "Timer-2" Exception in thread "http-8080-4" Exception in thread "http-8080-8" Exception in thread "http-8080-17" Exception in thread "org.hibernate.cache.StandardQueryCache.data" Exception in thread "org.hibernate.cache.UpdateTimestampsCache.data" Exception in thread "org.hibernate.cache.StandardQueryCache.data" Exception in thread "org.hibernate.cache.StandardQueryCache.data" Exception in thread "org.hibernate.cache.UpdateTimestampsCache.data" Exception in thread "org.hibernate.cache.StandardQueryCache.data" Exception in thread "org.hibernate.cache.StandardQueryCache.data" Exception in thread "org.hibernate.cache.UpdateTimestampsCache.data" Exception in thread "com.safenet.usermgmt.User.data" Exception in thread "http-8080-7" Exception in thread "http-8080-12" Exception in thread "http-8080-16" Exception in thread "http-8080-14" Exception in thread "http-8080-13" Exception in thread "http-8080-15" Exception in thread "http-8080-6" OpenJDK Client VM warning: Exception java.lang.OutOfMemoryError occurred dispatching signal SIGTERM to handler- the VM may need to be forcibly terminated

    Read the article

  • HOW TO save Contacts from iPhone to Computer?

    - by goodm
    Step 1: Download [b]Tansee iPhone Transfer Contact[/b] free trial version [url="http://softseeking.com/prodail.aspx?proid=47"]here[/url],then install the software (skip if done yet). u can download at:[url="http://www.softseeking.com/prodail.aspx?proid=47"]http://www.softseeking.com/prodail.aspx?proid=47[/url] Step 2: Connect iPhone to your computer. Step 3: Run Tansee iPhone Transfer Contact , your contacts on iPhone memory will display as shown in your iPhone screen automatically as fig 1. Click on single name, all his or her information will display as fig 2 shown. Step 4-a: In fig 1 situation, you can click button "Copy" to copy all contacts from your iPhone to your computer , then select options: 1: Choose File Type: backup to TXT file, ANTC file or CSV file; 2: Choose File Path: You can change the backup path if you do not use default path. 3: Advanced Option: if you choose ANTC format in step 1, you can add a password to protect the file. Note: We do not know the password, so please do remember it. Click OK Button to finish the Copy. See fig 3. Note: You can only copy the first 5 contacts with trail version.[/SIZE] [/SIZE] [size=3][size=3]Step 4-b: In fig 2 situation, click button "Copy Contact From who" to copy contact of a single person, select options: 1: Choose File Type: Backup contacts to TXT file, and CSV file in single contact transfer; 2: Choose File Path: You can change the backup path if you do not use default path; 3: Advanced Option: Disabled in single contact transfer. Click OK Button to finish the Copy. See fig 4. Note: You can only copy the first 5 contacts in trail version.[/size] [/size]

    Read the article

  • Hugepages not utilized by MySQL 5.0, CentOS 5

    - by TechZilla
    I've set up Hugepages, but i'm not seeing any of them reserved. Have I missed a step, or for some particular reason, is MySQL is unable to utilize the Hugepages? I have not created a mount of hugetlbfs, although from what I read, MySQL would not call pages in such a manner. If I'm wrong, please let me know, as that would be a trivial solution. Almost all my MySQL tables are using InnoDB. NOTE: I created a hugetlbfs, no change as expected. Is it possible that rebooting would rectify this situation? I would not want to go through the procedure, as this is high availability, but would do so if necessary. This is the configurations, which I believe are relevant. /etc/sysctl.conf ... ## Huge Pages vm.nr_hugepages = 4096 vm.hugetlb_shm_group = 27 ## SHM kernel.shmmax = 34359738368 kernel.shmall = 8589934592 ... /etc/security/limits.conf ... mysql soft nofile 12888 mysql hard nofile 51552 @mysql soft memlock unlimited @mysql hard memlock unlimited /etc/my.cnf [mysqld] large-pages ... grep Huge /proc/meminfo HugePages_Total: 4096 HugePages_Free: 4096 HugePages_Rsvd: 0 Hugepagesize: 2048 kB id mysql uid=27(mysql) gid=27(mysql) groups=27(mysql) context=root:system_r:unconfined_t:SystemLow-SystemHigh tail -6 /var/log/mysqld.log InnoDB: HugeTLB: Warning: Failed to allocate 1342193664 bytes. errno 12 InnoDB HugeTLB: Warning: Using conventional memory pool 120808 15:49:25 InnoDB: Started; log sequence number 0 1729804158 120808 15:49:25 [Note] /usr/libexec/mysqld: ready for connections. Version: '5.0.95' socket: '/var/lib/mysql/mysql.sock' port: 3306 Source distribution I would really appreciate any help, I'm completely out of ideas. If I missed any more relevant configs, or diagnostics, please comment and I'll add it to the question.

    Read the article

  • Debian/Ubuntu - No network connection

    - by leviathanus
    I have a very weird situation on my Ubuntu 12.04 LTS Server. I can not access (ping) my gateway, although I believe my config is ok - I attach the outputs. Any hints where to look? (I changed the beginning of the IP to something different, just obfuscation) ping 5.9.10.129 PING 5.9.10.129 (5.9.10.129) 56(84) bytes of data. From 5.9.10.129 (5.9.10.129) icmp_seq=2 Destination Host Unreachable From 5.9.10.129 (5.9.10.129) icmp_seq=3 Destination Host Unreachable From 5.9.10.129 (5.9.10.129) icmp_seq=4 Destination Host Unreachable uname -r 3.2.0-29-generic ifconfig eth0 eth0 Link encap:Ethernet HWaddr 3c:97:0e:0e:54:d7 inet addr:5.9.10.142 Bcast:5.9.10.159 Mask:255.255.255.224 inet6 addr: fe80::8e70:5aff:feda:c4ac/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:1216 errors:0 dropped:0 overruns:0 frame:0 TX packets:490 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:107470 (107.4 KB) TX bytes:34344 (34.3 KB) Interrupt:17 Memory:d2500000-d2520000 ip route default via 5.9.10.129 dev eth0 metric 100 5.9.10.128/27 via 5.9.10.129 dev eth0 5.9.10.128/27 dev eth0 proto kernel scope link src 5.9.10.142 route -n Kernel IP routing table Destination Gateway Genmask Flags Metric Ref Use Iface 0.0.0.0 5.9.10.129 0.0.0.0 UG 1000 0 0 eth0 5.9.10.128 5.9.10.129 255.255.255.224 UG 0 0 0 eth0 5.9.10.128 0.0.0.0 255.255.255.224 U 0 0 0 eth0 iptables -L Chain INPUT (policy ACCEPT) target prot opt source destination Chain FORWARD (policy ACCEPT) target prot opt source destination Chain OUTPUT (policy ACCEPT) target prot opt source destination UPD: Eric, this is how routing information looks on a working server: 0.0.0.0 78.47.198.49 0.0.0.0 UG 100 0 0 eth0 78.47.198.48 78.47.198.49 255.255.255.240 UG 0 0 0 eth0 78.47.198.48 0.0.0.0 255.255.255.240 U 0 0 0 eth0 As I understand it, Hetzner tries to ensure security by this, so I can not take over an IP by changing my MAC. But this is another server, which has another netmask (255.255.255.240) UPD2: BatchyX, on the working server: 78.47.198.49 dev eth0 src 78.47.198.60 cache on the broken: 5.9.10.129 dev eth0 src 5.9.10.142 cache

    Read the article

  • What is the best way to create a failover cluster for my IIS website?

    - by ObligatoryMoniker
    Our eCommerce website www.tervis.com currently runs on two servers: SQL server: 2005 x 86 on Windows Server 2003 Standard x86 with a single dual core processor and 4 gb of memeory IIS server: Windows Server 2008 Web edition x64 with dual quad core hyper threaded processors and 32 gb of memory Tervis.com's revenue has steadily grown to the point where we need to have redundant servers deployed with a fail over mechanism so that we do not have any down time. Because the SQL server is so underpowered compared to the web server my thought was to purchase: 2 x SQL Server 2008 R2 web edition x64 single processor license 2 x Windows Server 2008 R2 Web Edition Licenses 1 x New Physical dual quad core 32 GB server 1 x F5 Load Balancer I need the Windows Server 2008 R2 Web Edition licenses so that I can run SQL and IIS on the same box for both of these servers. The thought is to run this as an active/passive fail over cluster that could be upgraded to an active/active cluster if we purchased the additional SQL licensing. The F5 load balancer would serve as the device that monitors the two servers and if the current active one stops responding then fails over to using the other server. To be clear this is not windows clustering but simply using a load balancer to fail over between two computers so that you now have a cluster in the general sense. Is this really the best way to accomplish what I need? Is there some way to leverage the old server 2003 SQL server to function as the devices that funnels http requests to the appropriate active server and then fails over if a problem occurs? Is there any third party clustering software that might help me accomplish this in a simpler fashion?

    Read the article

< Previous Page | 561 562 563 564 565 566 567 568 569 570 571 572  | Next Page >