  • Default program not choosing on Windows 7

    - by Trollolz
    this is my first time posting and i need some help. I have a file named .kv6 format. I used slab6 (the correct and only program) to edit this file. I had it chosen as default program to open it upon double click. But today it stopped using that and reset to an unknown file. So I tried to set it again and when I hit "Browse" and select slab6 again it acts like it chooses it but doesn't actually show up as the default program or Other Programs. I can choose whatever other program and it will show up as a new Default Program but won't work to open it =\ Any help you be appreciated, thanks.

    Read the article

  • Windows shows incorrect free space on Raid 10 volume

    - by Adenverd
    I have 4 1TB hard drives in RAID 1+0 configuration. Theoretically, I should have ~2TB of available space. Windows says the drive has a total size of 1.81 TB, which I'm fine with. As far as files on the volume go, I used WinDirStat to determine that I have 552.8GB of files on the volume. This means that I should have somewhere around 1.3TB minimum of free space. Yet Windows shows the drive as only having 492GB of free space. Are there hidden files somewhere that I can't see (I have show hidden files/folders turned on)? Does Windows not recognize that old files have been deleted? Is there any way to correct this problem?

    Read the article

  • Opensolaris, ZFS shares

    - by Random
    I've recently updated to OpenSolaris 2010.05 from 2009.06. Its currently set up to share one of the the ZFS zpools to the other machines on my network. However, only a single account is able to access these shares. My other accounts get refused when attempting to connect. File permissions are all correct - When logging into the machine directly with the other logins, I can see, and play with the files and directories as normal - Its just the share that gets refused. The interesting thing is, I could access the shares prior to upgrading. Nothing else was changed other than the straight upgrade. I am pretty sure there is no user specific sharing going on. What could be preventing others from accessing this zpool?

    Read the article

  • Kill all currently running cron jobs

    - by Adelphia
    For some reason my cron job scripts aren't exiting cleanly and they're backing up my server. There are currently a couple hundred processes running for one of my users. I can use the following command to kill all processes by that user, but how can I simplify this to kill only crons? pgrep -U username | while read id ; do kill -6 $id ; done It would be dangerous to run the above command as is, correct? Wouldn't that kill mysql and other important things?

    Read the article

  • Windows Server 2003 R2 SIS Groveler start error

    - by 2040techman
    Hi I have a Windows Server 2003 R2 SP2 running and I need to have a WDS with mixed mode so I can deploy Windows 7 & Windows XP images. I went to setup the first image and after the wizard was done copying the correct files I got: Single Instance Storage Groveler: Service did not start (or something like that). I checked event viewer and got this: Event Type: Error Event Source: Service Control Manager Event Category: None Event ID: 7023 Date: 3/26/2012 Time: 7:03:21 PM User: N/A Computer: SERVER2 Description: The Single Instance Storage Groveler service terminated with the following error: The service has not been started. This server is needed very soon because we just got a shipment of several Windows XP capable laptops and need to deploy Windows XP over PXE and this is keeping us from proceeding. Any help is great!!!

    Read the article

  • How can I convince my boss that ANSI C is inadequate for our new project?

    - by justifiably cowardly
    A few months ago, we started developing an app to control an in-house developed test equipment and record a set of measurements. It should have a simple UI, and would likely require threads due to the continuous recording that must take place. This application will be used for a few years, and shall be maintained by a number of computer science students during this period. Our boss graduated some 30 years ago (not to be taken as an offense; I have more than half that time on my back too) and has mandated that we develop this application in ANSI C. The rationale is that he is the only one that will be around the entire time, and therefore he must be able to understand what we are doing. He also ruled that we should use no abstract data types; he even gave us a list with the name of the global variables (sigh) he wants us to use. I actually tried that approach for a while, but it was really slowing me down to make sure that all pointer operations were safe and all strings had the correct size. Additionally, the number of lines of code that actually related to the problem in hand was a only small fraction of our code base. After a few days, I scrapped the entire thing and started anew using C#. Our boss has already seen the program running and he likes the way it works, but he doesn't know that it's written in another language. Next week the two of us will meet to go over the source code, so that he "will know how to maintain it". I am sort of scared, and I would like to hear from you guys what arguments I could use to support my decision. Cowardly yours,

    Read the article

  • Font used for attachment title

    - by MartinC
    When I add an attachment to any document in Word 2010 the font used for the title has changed. I am not talking about adding a caption but the title that is shown automatically as part of the attachment icon: Anything which I attached before today is still showing with the correct font but any new items use a different font. This affects all types of attachments (for example, .msg, .xml, .css). I don't know what I have done to alter the behaviour. How can I change the font back to the default please?

    Read the article

  • how to know which display number for the variable DISPLAY to be exported when ssh to server

    - by insidepower
    When i ssh to server using -X, i always confuse about which display number i should export. It seems to me sometimes the display number has been used by something, so what i can do is only export DISPLAY=localhost:0 && xclock export DISPLAY=localhost:1 && xclock export DISPLAY=localhost:2 && xclock export DISPLAY=localhost:... until the clock appear. Then i will use that display number. Each time log in to the server, the display number which is able to tunnel the gui data correct would be different. I know many of such similar questions has been asked and answer. However I couldn't find answer to my question, anyone know about it? Thanks!

    Read the article

  • How to setup a scheduled task to run every 30 minutes? Windows Server 2003

    - by JL
    I'm having a problem running a scheduled task in Windows 2003 server, it ran for 4 hours, now it won't start up again. I will tell you exactly what I have done to create the task, please tell me if I am doing anything wrong. My objective is to have my task (console app) run every 30 minutes. I open control panel, scheduled tasks, add new scheduled task Browse for my application I want to run, a console app without any command line arguments I select, perform this task - Daily I select the start time (now 8:00 in the morning) Start date set to today Set the correct username + password Open advanced properties Repeat the task every 30 minutes for 24 hours Save and close. Anything wrong in the above mentioned steps I've implemented? Thanks in advance.

    Read the article

  • Static vs. dynamic memory allocation - lots of constant objects, only small part of them used at runtime

    - by k29
    Here are two options: Option 1: enum QuizCategory { CATEGORY_1(new MyCollection<Question>() .add(Question.QUESTION_A) .add(Question.QUESTION_B) .add...), CATEGORY_2(new MyCollection<Question>() .add(Question.QUESTION_B) .add(Question.QUESTION_C) .add...), ... ; public MyCollection<Question> collection; private QuizCategory(MyCollection<Question> collection) { this.collection = collection; } public Question getRandom() { return collection.getRandomQuestion(); } } Option 2: enum QuizCategory2 { CATEGORY_1 { @Override protected MyCollection<Question> populateWithQuestions() { return new MyCollection<Question>() .add(Question.QUESTION_A) .add(Question.QUESTION_B) .add...; } }, CATEGORY_2 { @Override protected MyCollection<Question> populateWithQuestions() { return new MyCollection<Question>() .add(Question.QUESTION_B) .add(Question.QUESTION_C) .add...; } }; public Question getRandom() { MyCollection<Question> collection = populateWithQuestions(); return collection.getRandomQuestion(); } protected abstract MyCollection<Question> populateWithQuestions(); } There will be around 1000 categories, each containing 10 - 300 questions (100 on average). At runtime typically only 10 categories and 30 questions will be used. Each question is itself an enum constant (with its fields and methods). I'm trying to decide between those two options in the mobile application context. I haven't done any measurements since I have yet to write the questions and would like to gather more information before committing to one or another option. As far as I understand: (a) Option 1 will perform better since there will be no need to populate the collection and then garbage-collect the questions; (b) Option 1 will require extra memory: 1000 categories x 100 questions x 4 bytes for each reference = 400 Kb, which is not significant. So I'm leaning to Option 1, but just wondered if I'm correct in my assumptions and not missing something important? Perhaps someone has faced a similar dilemma? Or perhaps it doesn't actually matter that much?

    Read the article

  • Is it normal for the laptop charger to spark when plugging in?

    - by Cd-MaN
    All the laptop chargers I had until now sparked whever I plugged them in. This is true for my old charger (the bulkier / rounder Dell model) and the new charger (the flat Dell model) with two different Dell laptops, however until recently I didn't give it much thought. Then, in the last couple of months: I shorted out a conference room and melted the floor a little (the wire caught fire) The second charger (also a Dell original) died, taking the power strip with it I'm wondering: Is it normal for laptop chargers to spark when plugged in? Specifically new, original Dell chargers Is there a "correct" way to plug / unplug chargers? Do I need to first unplug it from the wall and then from the laptop / do I need to first plug it into the wall and then into the laptop? May the problem be caused by the fact that I leave sometimes the charger plugged into the wall without connecting the laptop for longer periods of time (up to a day)? PS. I'm talking about Europe, so 220V and this happens in many places (at home, at my parents, at work, in hotels I trave to, etc)

    Read the article

  • Problem installing wine on Ubuntu 12.10

    - by akhumaini
    I am having problem when installing wine on ubuntu 12.10 I tried to following some tutorial but none of them work. **root@ubuntu:~# add-apt-repository ppa:ubuntu-wine/ppa** **root@ubuntu:~# apt-get update** **root@ubuntu:~# apt-get install wine1.5** Reading package lists... Done Building dependency tree Reading state information... Done Some packages could not be installed. This may mean that you have requested an impossible situation or if you are using the unstable distribution that some required packages have not yet been created or been moved out of Incoming. The following information may help to resolve the situation: The following packages have unmet dependencies: wine1.5 : Depends: wine1.5-i386 (= 1.5.16-0ubuntu1) but it is not installable Recommends: ttf-droid Recommends: ttf-mscorefonts-installer but it is not going to be installed Recommends: ttf-umefont but it is not going to be installed Recommends: ttf-unfonts-core but it is not going to be installed Recommends: winbind but it is not going to be installed Recommends: winetricks but it is not going to be installed E: Unable to correct problems, you have held broken packages. root@ubuntu:~# Anyone can help me how to solve th problem ?

    Read the article

  • Hosting-why should I pay? [on hold]

    - by user196919
    Can I avoid, eliminate or neutralize propagation? Hours of research for a first-time unregistered domain returned the usual suspects ("Oneandblank", "GoBlanky", "BlankCow", "HostBlank-or" and others)all with 24-72hr or more. Would a roll-your-own, inhouse SHO Linux/Winserver box help? Thank you so much! edit; navigating SF for my first time I now notice the "professionals" air and feel to the comments. Although I feel justified for being here(armed with directly relevant, well-rounded knowledge/proficiency/experience)I apologize for diving in headlong without proper post etiquette or correct placement. I envy each of you and hope to gain my own inviolable foothold in the coming years.

    Read the article

  • Setting nagios location in map

    - by Mech Software
    I have Nagios installed and I'm working on getting the network map correct. The problem I have is that "Nagios" appears to be in the "internet" when it should be located on the MechNAS server. What I want is Nagios Process to show up inside the local network. So it should show up at the same layer as MechNAS and development. Where exactly is that configured? I didnt see any place to set that up and it looks now like it's out there on it's own. Documentation and Googling didnt seem to turn up anything either.

    Read the article

  • Trouble installing from disk

    - by SuperNatural
    I'm writing this in desperation, Windows is slowly killing me and i need to change my home pc os to Ubuntu 11.04 as soon as possible. I created a USB flash drive to install ubuntu, twice, and both times they failed to begin install on restart of my pc. i read on another forum that you might have to change some boot sequence in BIOS but when pressing F2 to enter it didnt work. After a lot of cursing, I made myself an UBUNTU install cd and booted. To my excitement, it now displayed... try ubuntu and install ubuntu. i clicked install ubuntu which lead me to the preparing to install ubuntu display, i checked download updates while installing and clicked forward. The very next display is ' allocate drive space ' i assume there are meant to be options of drives provided but mine is just a blank box and underneath all the options to create a new partition table, add, change, delete and revert are all greyed out. There is a drop down menu labelled 'device for boot loader installlation' but the only option is /dev/sda. when i click install, a no root file system error comes up telling me to please correct from the partitioning menu. I am extremely frustrated. please!! can anyone help me...

    Read the article

  • How can I log the response header and body in apache?

    - by acme
    I need to determine whether the server (Apache 2) is returning the full contents of a page along with its correct header or not. I have a PHP-script that is executed successfully, but the browser is getting only half of the html content, it's simply cut off. The client infrastructure is pretty complicated, using Novell BorderManager Proxys and stuff. To ensure the server is doing its job fine I want to log both header and body of the reponse. How can I achieve this? I looked into the mod_log_config module of apache (which is already installed and ready to be used), but honestly I didn't quite manage to configure it to output header and body somewhere. edit: I managed to log the header with LogFormat "%h %l %u %t \"%r\" %s %b \"%{HEADER_NAME}o\"" common2 CustomLog /var/log/apache2/response.log common2 But unfortunately the mod_log_config formats don't support the whole content body. Can anyone help?

    Read the article

  • How to run multiple Nginx instances on different port...

    - by Edvinas
    Hi, I would like to have several Nginx instances running on my server on separate ports (for example one user runs Nginx on port 2345, and another user on port 2346). So far, I have been successful in compiling and running the server on their designated ports. However, I am running into a weird issue: If i visit domain1.com:2345 or domain2.com:2346 I get the correct (200) response but if I visit domain1.com or domain2.com (without specifying the port) I get no response at all. Any help/clues in figuring out how to set this up would be highly appreciated.

    Read the article

  • colliding btRigidBody objects behave strangely when moving slowly

    - by Piku
    I'm trying to use Bullet Physics in my iOS game. The engine appears to be correctly compiled in that the demos work fine. In my game I have the player's ship and some enemy ships. They're defined as btRigidBody objects and btCollisionObjects and I'm using btSphereShapes for collision. At 'fast' speeds, collisions appear to happen sensibly - things collide and nothing goes 'weird'. If the speeds are very slow though and the player's ship touches a non-moving object the collision happens, but then the player's ship moves at incredible speed over the next few frames and appears a long distance from where it collided - completely out of proportion to the speed it was moving before impact. To move the things around I'm using setLinearVelocity() each frame, ticking the physics engine, then using getMotionState() to update the rendering code I have. Part of the issue might be I don't quite understand how to set the correct mass or what the best speeds are to use for anything. I'm mostly sticking numbers in and seeing what happens. Should I be using Bullet in this way, and are there any guidelines for deciding on the mass of objects? (am I right in assuming that in collisions heavier objects will force lighter objects to move more)

    Read the article

  • Why can't I change the icon being displayed for a desktop shortcut?

    - by Bill
    I wanted to change the icon showing for a shortcut on the desktop, which points to a .Net utility I created for myself. I rebuilt the exe after changing the icon used within the project. In Windows Explorer the new icon shows in all size variations for the exe. In the 'Change Icon' dialog from the Properties option, the correct icon is showing as present, yet when I Apply it remains with the old icon??? Even when I delete the shortcut and create a new one pointing to the newly built exe the old icon somehow is assigned???

    Read the article

  • How to extend a file definition from an existing module in the node?

    - by c33s
    I use an older version of the example42 mysql module, which defines the mysql.conf file but not its content. Mmy goal is to just include the mysql module and add a content definition in the node. class mysql { ... file { "mysql.conf": path => "${mysql::params::configfile}", mode => "${mysql::params::configfile_mode}", owner => "${mysql::params::configfile_owner}", group => "${mysql::params::configfile_group}", ensure => present, require => Package["mysql"], notify => Service["mysql"], } ... } node xyz { include mysql File["mysql.conf"] { content => template("mymodule/mysql.conf.erb")} } The above code produces a "Only subclasses can override parameters" What is the correct way to just add a content definition to an existing file definition?

    Read the article

  • designing solution to dynamically load class

    - by dot
    Background Information I have a web app that allows end users to connect to ssh-enabled devices and manipulate them. Right now, i only support one version of firmware. The logic is something like this: user clicks on a button to run some command on device. web application looks up the class name containing the correct ssh interface for the device, using the device's model name. (because the number of hardware models is so small, i have a list that's hardcoded in my web app) web app creates a new ssh object using the class loaded in step 2. ssh command is run and session closed. command results displayed on web page. This all works fine. Now the end user wants me to be able to support multiple versions of firmware. But the catch is, they don't want to have to document the firmware version anywhere becuase the amount of overhead this will create in maintaining the system database. In other words, I can't look up the firmware version based on the device. The good news is that it sounds like at most, I'll have to support two different versions of firmware per device. One option is to name the the classes like this: deviceX.1.php deviceX.2.php deviceY.1.php deviceY.2.php where "X" and "Y" represent the model names, and 1 and 2 represent the firmware versions. When a user runs a command, I will first try it with one of the class files, if it fails, i can try with the second. I think always try the newer version of firmware first... so let's say in the above example, I would load deviceX.2.php before deviceX.1.php. This will work, but it's not very efficient. But I can't think of another way around this. Any suggestions?

    Read the article

  • How to deploy Windows-8 Enterprise Apps to other users?

    - by TToni
    Windows-8 (Metro) Apps can be installed using "sideloading", bypassing the Windows store in enterprise environments. In principle this is easy: Once you enabled sideloading (which is automatically done when a Win8-machine joins a domain), you can install a signed appx-Package through PowerShell with the "Add-AppxPackage" command. But there is a catch: The App is only installed for the user who executes the command and there is no "-Credentials" parameter! I can probably solve that problem in my specific scenario, where I deploy a self-developed app through TFS build to a virtual machine with a fixed demo user (by using remote powershell in combination with "Add-Job", which does take a credential parameter and because I know the given username and the password). But that is not true in an enterprise environment, where I want to distribute my App to thousands of users. Cracking all their passwords seems a bit over the top, so what would be the "correct" way to do this? I can't find any useful information from Microsoft about this, but maybe one of you already ran into this problem and solved it?

    Read the article

  • Running a script on startup before X starts in Ubuntu 9.10

    - by Epcylon
    I have a script that I want to run at startup to switch X-configs depending on location, but I can't seem to find out where to put it in order to get it to run before X is started. This results in me having to restart X to get it to run the correct config. Currently, my script is located in /etc/init.d/whereami, with symlinks in /etc/rc[2-5].d/S25whereami. I was trying to find out when X is started, in case the problem is simply the 25, but I can't seem to find the answer... Any help is appreciated.

    Read the article

  • Weblogic Class-Path Dependencies EAR

    - by Mo
    I am deploying an EAR in a WebLogic node with many jars defined in the bootstrap (startWeblogicServer.bat) class-path. The problem is that my ear and the bootstrap contain different versions of the same jars, not only that but certain jars contain extracted third party libraries which also differ in version from the WebLogic bootstrap jars causing all kinds of classpath errors. I know you can set preferred jars in the EAR application xml but, this can be very tedious to resolve with regards to jars which include extracted third party libraries in terms of understanding all the dependencies.. Is there a correct approach that i need to be taking here? Am i thinking about this in the wrong way? Any help would be greatly appreciated! So far prefer-web-inf-classes has been recommended but wont work because i'm not deploying a WAR, also prefer-application-packages is what we are currently using but still has the issue described above... Anymore advice out there?? Thanks!

    Read the article

  • Where to start when setting up a gambling website [closed]

    - by molleman
    I don't know if this is the correct place or this question by I couldn't find anywhere else. I am looking into building a gambling website, I have good HTML CSS and JavaScript skills but I do not know enough of the server side to actually build a backend for a gambling website. Firstly where would you start , what language , I work With Wordpress , so I understand php a little but not a lot . Would php be a good place to start . If so what framework would be able to scale if the number of users on the website increased . clearly I would like a backend where you could view 1. Users 2. Transactions 3. input games which you can bet on And so on.. Also users should be able to see all there associated information If anyone could help that would be great.

    Read the article