  • NTBackup (on WS2k3) fails to backup remote server (WS2k8R2) with " Error: is not a valid drive, or you do not have access."

    - by Mark A
    We run an NTBackup job on a Windows Server 2003 R2 SP2 with all updates (as of Q4-2011). It works well backing up two WS2k3 servers as well as the backup server itself. However, we have been unable to successfully back up our Windows Server 2008 R2 machine ("G5-01"). It often runs for about 2GB worth of backup and then dies out with one of the below error messages. It should be more like 20GB for the full server. We have tried using the admin share (C$), an explicitly shared drive share, UNC and mapped drives. The result is the same each time, the only thing that varies is the amount of stuff backed up before it chokes. We've also run NTBbackup from the UI interface, from the command line and as a scheduled task. We are backing up to 400/800GB tapes and they have plenty of space available on them (blank media). Error: \\G5-01\c is not a valid drive, or you do not have access. Error: \\G5-01\c$ is not a valid drive, or you do not have access. Error: Y: is not a valid drive, or you do not have access. Error: Could not access or create backup catalog files. Verify that you have full access to the working folder and there is disk space available. The job is run as Administrator and we have no problems logging onto the server and transferring files. The Event Log on the WS2k8 is not much help, as it has success audits for each login. All of the hardware involved (HP DL360 G3, HP LTO Ultrium 3, Adaptec 39320A) has the latest supported drivers. We've seemingly tried a bunch of different options but are wondering where to look next to resolve the backup issue. We've been super happy with our reliable schedule task for years but this one is stumping us!

    Read the article

  • Enterprise class storage best practices

    - by churnd
    One thing that has always perplexed me is storage best practices. Filesystems brag about how they can be petabytes or exabytes in size. Yet, I do not know many sysadmins who are willing to let a single volume grow over several terrabytes. I do know the primary reason behind this is how long it would take to rebuild the array should a drive fail. The more drives in a single LUN, the longer this takes and the greater your risk of losing another drive while the rebuild is taking place. Then there's usage reasons. Admins will carve out a LUN based on how much space they think needs to be allocated to the project. It seems more practical to me for the LUN to be one large array and to use quotas. I understand this wouldn't satisfy every requirement (iSCSI), but I see a lot of NAS systems (NFS) managed this way. I also understand that the underlying volumes can be grown/shrunk as needed quite easily, but wouldn't it be less "risky" to use quotas rather than manipulating volumes and bringing possible data loss into the equation? There may be some other reasons I'm missing, so please enlighten me. Can we not expect filesystems to ever be so large? Are we waiting for the hardware to get faster to cut down on rebuild times?

    Read the article

  • How can I update generic non-pnp monitor?

    - by njk
    Background I've been running a KVM switch with my monitor at 1920 x 1080 over VGA for over a year. Did a Windows Update on 12/11/12 which did the following: Update for Windows 7 for x64-based Systems (KB2779562) Security Update for Windows 7 for x64-based Systems (KB2779030) Cumulative Security Update for Internet Explorer 8 for Windows 7 for x64-based Systems (KB2761465) Windows Malicious Software Removal Tool x64 - December 2012 (KB890830) Security Update for Windows 7 for x64-based Systems (KB2753842) Security Update for Windows 7 for x64-based Systems (KB2758857) Security Update for Windows 7 for x64-based Systems (KB2770660) After a restart, my extended monitor was dark. I attempted to reset the extended display configuration, and noticed my monitor was being detected as a Generic Non-PnP Monitor: I uninstalled, downloaded new, and re-installed display drivers. Nothing. I attempted to unplug my monitor from the power for 15 minutes. Nothing. I followed some of the suggestions on this thread; specifically DanM's which suggested to create a new *.inf file and replace that in Device Manager. Device Manager said the "best driver software for your device is already installed". The only thing that works is when the monitor is directly attached to the laptop. This obviously is not what I want. My thought is to somehow remove the Generic Non-PnP Monitor from registry. How would I accomplish this and would this help? Any other suggestions? Relevant Hardware ASUS VE276 Monitor TRENDnet 2-Port USB KVM Switch (TK-207K) HP Laptop w/ ATI Radeon HD 4200 Screens

    Read the article

  • Windows 7 BSOD on startup

    - by Cristy
    I got a BSOD today after getting home from 11 hours of work... It seems to work in SAFE MODE (sometimes, not always) The BSOD says: SYSTEM_SERVICE_EXCEPTION STOP: 0x0000003b WimFsf.sys - Address FFFFF88001A6B76B base at FFFFF88001A600000, DateStamp 4a5bc362. Sometimes it shows the welcome screen, shows the destkop for a few seconds and then BSODs Already did: unplugged all the USB devices reset the CMOS I haven't installed any new software recently. What should I do? EDIT: I've managed to get into safe mode and it seems to works fine. When I go into normal mode it shows the desktop then it freezes... Is it more likely to be a software or hardware problem? EDIT2: I've managed to get into normal mode by disabling all the non-microsoft services & startup programs. One more thing: When I shut down my PC, on the "Logging off" screen appear some artifacts. I don't think it's because of my graphics card cause I've opened Black OPS and it worked fine. It's so strange... It still BSODS on startup (but there a ~=10% that it will not), and when it doesn't BSOD's it works fine...

    Read the article

  • How to configure a Linux kernel based on the modules currently in use?

    - by Carla
    Hello, I'm willing to build a minimal kernel with only the needed things for my machine; so I started by compiling the kernel from the ground up, using the default configuration and adding things that I know for sure I have (i.e.: Ethernet card, WiFi card, ...). But there are several other things not so easy to know about (i.e.: the watchdog timer) so I came across AutoKernConf which supposedly detects the hardware of the machine and generates a kernel configuration file with the settings for the found devices. The problem is it contained several settings repeated and even some which I don't have (I'm using a Dell laptop and one of the things it "found" was something of a Toshiba one). So I ended up building a kernel with the configuration that came out of the make allmodconfig command, which is a kernel with most of the things compiled as modules. Booting into that kernel and running lsmod I can see all of the kernel modules in use (the ones really needed) and I would like to know if there is a tool or some way for me to parse that list and convert it to the corresponding kernel configuration file. Or how to map each one with the appropriate options in the kernel so that I can manually set them. Thank you very much for your time.

    Read the article

  • UDP blocked by Windows XP Firewall when sending to local machine

    - by user36367
    Hi there, I work for a software development company but the issue doesn't seem to be programming-related. Here is my setup: - Windows XP Professional with Service Pack 3, all updated - Program that sends UDP datagrams - Program that receives UDP datagrams - Windows Firewall set to allow inbound UDP datagrams on a specific port (Scope: Subnet) If I send a UDP datagram on any port to other, similar machines, it goes through. If I send the UDP datagram to the same computer running the program that sends (whether using broadcast, localhost IP or the specific IP of the machine), the receiver program gets nothing. I've traced the problem down to the Windows XP Firewall, as Windows 7 does not have this problem (and I do not wish to sully my hands with Vista). If the exception I create for that UDP port in the WinXP firewall is set for a Scope of Subnet the datagram is blocked, but if I set it to All Computers or specifically enter my network settings (192.168.2.161 or 192.168.2.0/255.255.255.0) it works fine. Using different UDP ports makes no difference. I've tried different programs to reproduce this problem (ServerTalk to send and either IP Port Spy or PortPeeker to receive) to make sure it's not our code that's the issue, and those programs' datagrams were blocked as well. Also, that computer only has one network interface, so there are no additional network weirdness. I receive my IP from a DHCP server, so this is a straightforward setup. Given that it doesn't happen in Windows 7 I must assume it's a defect in the Windows XP Firewall, but I'd think someone else would have encountered this problem before. Has anyone encountered anything like this? Any ideas? Thanks in advance!

    Read the article

  • effective back-up using Raid / Win7 back-up

    - by Job
    I have a stand-alone pc system with two 2 tb harddiscs, one of which configured as Raid1, i.e. mirorring. The operational drive is partitioned. I use an external 1 tb harddisc for back-up using Windows 7 back-up facility which will be swapped weekly and stored on other premises. I back-up all partitions AND allow a system back-up. All application software is on the C: partition. Questions: How can I see whether Raid1 is working; i.e. is doing its job. All I see now is a status message in the start-up procedure that says its status is normal. How can I see used or available space on Raid 1? The Win-7 backup allows for 1 schedule only as far as I can see. I want daily back-ups of data. However due to the single schedule I am forced to do the time-consuming system back-up and c: back-up as well. Is there a way to activate two schedules allowing a frequent (daily) data back-up and a system back-up with c: drive back-up on a say weekly basis? Of course it can be forced by hand but I am likely to forget that. I am not the programming type of person so looking for simple and controllable solutions. Thank you - any help is apreciated.

    Read the article

  • Is there a historical computer peripherals or accessories museum or even just a current list?

    - by zimmer62
    Thinking about all the unique and different peripherals I've owned over the years, from ISA capture cards, to parallel port controlled shutter glasses for 3d games. I've seen many many accessory or computer peripherals come and go. The nostalgia of these things is a lot of fun. I tried to find some sort of historical time-line or list but what mostly turned up is computers themselves. I'm more interested in the mice, scanners, the weird adapters that shouldn't exist, short run very rare products, strange devices from computer shows in the 80's and 90's... Hardware you might find in a geeks basement that would be completely useless now, but was the coolest thing around when it was new. An example would be a drawing tablet I had for my TI-99 computer, or the audio tape player accessory for a C64 which let you save files to audio tapes, An ISA card that did the same for PC's hooked up to a VCR. Remember that IBM-PC Jr upgrade kit, that added a floppy drive, more memory and the AT switch in the back? I'd love to find either a wiki, or a list that has already been assembled which contain many of these weird (or common) accessories. I've had so many over the years I suppose I could start a wiki here if such a list doesn't already exist.

    Read the article

  • Legalities of freelance security consultant (SQLi) [closed]

    - by Seidr
    Over the years I've gained a large amount of experience in Programming (my main occupation) and server admin, and as a result have a fairly decent backing in security practices. I'm also pretty good at spotting security flaws in software (including but not limited to SQLi), and have built up a list of sites that could definately use some looking at. My question is, what are the legalities of me contacting these sites saying something along the lines of "I've looked at your site and it appears vulnerable - customer data could be compromoised - would you like me to fix it?". Could me finding out that the site is infact vulnerable be construed as an attack itself? If the prospective client so wished, could they take me to court over this? When I find a vulnerable site, all I do is confirm and make a note of the vulnerability. I'm not in it for personal gain (getting paid for FIXING it would be nice!), just curiosity. Is this a viable way to go about finding clients for this kind of work, or would you recommend a more 'legitimate' way? Any suggestions/advice would be greatly appreciated :)

    Read the article

  • Windows 7 BSOD when I walk away from the computer

    - by bobobobo
    I have a really weird experience with this new AM3 box I set up. Everything seems fine at first. But now I get frequent (daily) BSOD's, mostly when I walk away from the computer for more than 5 minutes (when the computer is idle). The BSOD's as shown by BlueScreenView almost always have to do with ntoskrnl.exe, and they'll do with really normal sounding operations, like SYSTEM_SERVICE_EXCEPTION, NTFS_FILE_SYSTEM, DRIVER_IRQL_NOT_LESS_OR_EQUAL, KMODE_EXCEPTION_NOT_HANDLED, BAD_POOL_HEADER - You name it. These are basically them, and they repeat after that, just random order. Its not like one is more consistently the problem than the other. I have Windows update ON and I let it do its updates everytime it wants to. I turned windows indexing service off, but it seems Windows 7 does a lot of background processing when I'm away - I'll come into the room and the fan will be going nuts (I'm pretty sure this isn't because the computer flies into a panic whenever I leave). I tried finding updates for my ASUS, and really there isn't much to install (except some new driver firmware). I'm going to install that to see if it helps, but what else could it be? Is it possible its a hardware issue with the board? Or is every Windows 7 user experiencing daily BSOD these days that I don't know about?

    Read the article

  • SSH Interactive mode not working

    - by Ekin Koc
    I have a Debian based linux server running for a year or so, without any problems. A couple of days ago, ssh interactive mode stopped working for no reason. I mean, I can open an ssh connection just fine, the server greets me with shell but I just can't type anything. However, if I send commands like this: ssh [email protected] cat /var/log/messages, I get the response. I dug through several logs and found one message, which feels remotely relevant to the problem; sh kernel: [10222733.062511] ------------[ cut here ]------------ sh kernel: [10222733.062522] WARNING: at /build/buildd-linux-2.6_2.6.32-39-amd64-7yVIH2/linux-2.6-2.6.32/debian/build/source_amd64_none/drivers/char/tty_ldisc.c:738 tty_ldisc_reinit+0x46/0x7b() sh kernel: [10222733.062526] Hardware name: PowerEdge R210 II sh kernel: [10222733.062528] Modules linked in: ipt_MASQUERADE iptable_nat nf_nat nf_conntrack_ipv4 nf_conntrack nf_defrag_ipv4 ip_tables x_tables sha1_generic arc4 ecb ppp_mppe ppp_async crc_ccitt ppp_generic slhc loop snd_pcm snd_timer snd soundcore snd_page_alloc i2c_i801 i2c_core pcspkr evdev joydev dcdbas container button processor ext3 jbd mbcache sg sd_mod sr_mod crc_t10dif cdrom usb_storage usbhid hid mpt2sas ahci ehci_hcd libata scsi_transport_sas usbcore bnx2 nls_base scsi_mod fan thermal thermal_sys [last unloaded: scsi_wait_scan] sh kernel: [10222733.062568] Pid: 8662, comm: sshd Not tainted 2.6.32-5-amd64 #1 sh kernel: [10222733.062569] Call Trace: sh kernel: [10222733.062572] [<ffffffff811ff056>] ? tty_ldisc_reinit+0x46/0x7b sh kernel: [10222733.062574] [<ffffffff811ff056>] ? tty_ldisc_reinit+0x46/0x7b Is there any way to get back the sshd working in interactive mode? I tried restarting sshd but that is no help. And somehow, I can not reboot the server. Tried sending shutdown -r now and reboot but it refuses to go down. Should I go ahead and request a physical reboot?

    Read the article

  • External Storage for 2TB of backups and 4TB of data RAID level? HW vs Software?

    - by Jerry Mayers
    I have a Mac Mini set up as a media center/file server. Currently I just have a hodgepodge mess of external drives for storage. I'm maxed out, and I have some new laptops on the way with much larger drives and I need to work out a good storage solution for backing them up, as well as storing media on the server. I need around 2 TB of storage for the time machine backups from my various systems and around 2 TB more for media. I would like to build this to handle around 6 TB total so I have some growing room. Since I'm using a Mac Mini as the server I need to use external enclosure(s) that support USB 2 or Firewire 800 (preferred) or gigabit Ethernet. Performance of the system isn't a huge concern since the majority of the access from other computers is done over 802.11N. I plan on using 2TB drives, for the final version, but initially I'll try and use my existing 2 (1TB) drives + some new 2TB drives, and swap the 1TB ones out as I fill up. As to the actual questions: Should I use hardware RAID in some enclosure? Because if the enclosure dies I have to find an identical one to get to my data right? Wouldn't a software RAID be better as I can use any method of connecting the drives to the system? Remember OS X server is my OS. What if I had to reinstall OS X, can I restore the software RAID easily? What RAID version should I use? For the 2TB used for the time machine disk I don't see why I need RAID here, just a single 2TB drive since its already the backup, but for the remaining 4TB it would be the only copy of the data so I should build some redundancy. I had a RAID 5 setup using a cheep RAID PCI card years ago running RAID 5 in a 2 TB array and when a drive died it wanted 48 hours to rebuild. Is this crazy slow for a setup of this size or is this to be expected? Any suggestions as to drive enclosures?

    Read the article

  • What should be monitored to troubleshoot file sharing problems?

    - by RyanW
    I'm running into some problems with a file share used by an ASP.NET web application. With this configuration, there are 2 web servers (win2k8 web) that connect to a file server (win2k8 enterprise), reading and writing files using a file share. Recently, one of the web servers has begun encountering an error accessing the file share: IOException: The specified network name is no longer available. There does not appear to be much info on the web for explaining what's causing this and how to best fix it, so I'm looking at what I can monitor in order to get clues. I'm not sure if it's hardware, just a load issue, file size, frequency, etc. With Windows perfmon, what can I monitor on the File Server side? There's the "Files Open" object, any other good ones? What can I monitor on the web server side? EDIT: I'll add that the UNC path uses the IP address of the file server, not a name to resolve. Also the share is a single, flat directory with over 100K files.

    Read the article

  • After upgrading to 2008 R2 Enterprise and installing more RAM, Windows can only see 4.00 GB

    - by Tom Crane
    (I have also posted this on technet but I'm running out of ideas) I've upgraded from Windows Server 2008 R2 Standard to Enterprise in order to make use of more RAM. The server previously had 32GB of RAM. The upgrade from Standard to Enterprise, using DISM, seemed to go OK, so I powered down and installed the RAM. This a Dell Poweredge T710, I was taking it from 32GB to 72GB. The BIOS recognised the RAM, although I needed to change from "Advanced ECC" to "Optimizer" mode for it to use all of it. After rebooting, windows can see the RAM but in the system panel will display: Installed memory (RAM): 72.0 GB (4.00 GB usable) In the resource monitor, the remainder of the RAM is showing as reserved for hardware. I've tried various RAM configurations, including reverting it to the same chips and same configuration as before the upgrade, but always just 4.00 GB is showing up as usable. Following some threads on these forums I've gone into msconfig and set the maximum memory "by hand" but that doesn't fix the problem. BIOS doesn't seem to have anything that looks like memory remapping which is another suggestion that has come up. How do I make this RAM available to Windows? It was available before the upgrade, because I could use the full 32GB RAM the server had to start with. A screenshot (this is after reverting to the original RAM configuration) http://screencast.com/t/5FuzevdNb I don't know if it's related, but my remote desktop configuration has also disappeared: screencast.com/t/mYedomeQWS (the bottom half of this dialog should allow me to configure Remote Desktop, it was working before the upgrade but now it isn't).

    Read the article

  • Do eSATA HDD docking stations have a capacity limit?

    - by Michael Kjörling
    I'm looking at perhaps buying an eSATA docking station to be able to easily plug in and unplug hard disk drives, particularly but not necessarily only for backup purposes. Note: This is not a hardware shopping recommendation question. Please don't vote to close it as such. Looking at different models, I find for example this page detailing the Deltaco SI-7908SUS which specifically states "storage capacity: 1.5 TB" as well as "pictured hard disk not included, only for illustration". A customer review specifically mentions that it does not work with 3 TB drives, although does not go into any detail such as OS, drive model, etc. From a brief glance, the vendor's web site does not appear to say either way. Then there is the quite similar Deltaco SI-7908B3 which boasts on the box "all 2.5" and 3.5" HDD/SSD compatible". My question is: Why would what basically amounts to a SATA/eSATA adapter have any say in what storage capacity devices are supported? Does it? Assuming the OS supports the full capacity of the drive, why should introducing another (not even a different, really) connector change anything? Bonus question: Might it make a difference if the docking station exposes multiple interfaces (such as in the case of for example the SI-7908SUS exposing USB 2.0 and eSATA)? (I still think it shouldn't, but it'd be nice to have it confirmed.)

    Read the article

  • Debian Bluetooth headphones not working

    - by cYrus
    Hardware Headphones Bluetooth dongle Maybe not exactly these models. Setup I tried to follow some guides, here's what I've done so far: Install software: sudo apt-get install bluez-utils bluez-alsa Reboot (just to be sure): $ dmesg | grep -i bluetooth [ 20.268212] Bluetooth: Core ver 2.16 [ 20.268230] Bluetooth: HCI device and connection manager initialized [ 20.268233] Bluetooth: HCI socket layer initialized [ 20.268235] Bluetooth: L2CAP socket layer initialized [ 20.268239] Bluetooth: SCO socket layer initialized [ 20.284685] Bluetooth: RFCOMM TTY layer initialized [ 20.284692] Bluetooth: RFCOMM socket layer initialized [ 20.284693] Bluetooth: RFCOMM ver 1.11 [ 20.335375] Bluetooth: BNEP (Ethernet Emulation) ver 1.3 [ 20.335378] Bluetooth: BNEP filters: protocol multicast The deamon is running: $ /etc/init.d/bluetooth status [ ok ] bluetooth is running. Plug the dongle: $ dmesg | tail [...] [23108.352034] usb 5-2: new full-speed USB device number 2 using ohci_hcd [23108.571131] usb 5-2: New USB device found, idVendor=0a12, idProduct=0001 [23108.571136] usb 5-2: New USB device strings: Mfr=0, Product=0, SerialNumber=0 [23108.629042] usbcore: registered new interface driver btusb Put the headphones in pairing mode, and try scanning: $ hcitool scan Scanning ... Found nothing. What's next? What should I try? I'll update this answer as soon as you provide me hints.

    Read the article

  • Expresscard Not Detected in PCI-E Adapter

    - by maxpower47
    I'm trying to put an expresscard TV tuner (Avermedia HC82) into my HTPC using this expresscard to PCI-E adapter. I've verified that the tuner works fine in my laptop. The motherboard is a Biostar TF7050-M2. When I install it and turn it on, the light on the back of the adapter comes on fine (there are two indicator lights on the back to show if it is using PCI-E or USB communication, USB communication goes through a USB cable connected between the card and a header on the motherboard) showing that it is working in PCI-E mode. However, the device is never detected in Windows 7 Professional x64. The auto detect never happens, it doesn't show up in the device manager, and I can have it rescan for new hardware and nothing is found. I tested the whole setup (tuner + adapter) in another PC (also using Win 7 Pro x64) and it worked fine. I also tried: Plugging the adapter in to the PCI-E x16 slot on the motherboard (I verified first that the x16 slot worked by installing a video card in it) Booting into safe mode and rescanning Updating the chipset drivers Installing the tuner drivers first Using a different USB cable, plugged in to one of the known good ports on the back of the board Trying it without the USB cable plugged in Removing the other PCI cards that were installed on the board Looking through the BIOS for any setting that might be disabling it somehow to no avail. I'm at a loss for what else to try. I really don't want to RMA it (the shipping back to newegg will be almost as much as it cost to buy in the first place. Any ideas?

    Read the article

  • Transferring an SQL Processor License to a virtual hosted environment

    - by Andrew Shepherd
    My company is currently hosting a service in-house, and we want to move to an externally hosted environment. We would then be using a virtual server. I understand that this might be spread across multiple machines, but from my perspective as a customer, this layer is abstracted away - I shouldn't know or care about the hardware that the OS is hosted on. We have a licensed edition of SQL Server 2008. This is one Processor license. Will it be a violation of the licensing agreement to use this in a virtual environment. From the reference guide here it says When licensed Per Processor With Workgroup, Web, and Standard editions, for each server to which you have assigned the required number of per processor licenses, you may run, at any one time, any number of instances of the server software in physical and virtual operating system environments on the licensed server. However, the total number of physical and virtual processors used by those operating system environments cannot exceed the number of software licenses assigned to that server For enterprise edition there is an added option: if all physical processors in a machine have been licensed, then you may run unlimited instances of SQL server 2008 in one physical and an unlimited number of virtual operating environments on that same machine. I'm having trouble getting my head around this. Would I theoretically have to get a license for every processor in this virtual environment (which is effectively impossible because I have no way of knowing how many processors there actually are)? Or can I just say that it's hosted on one "virtual" server, so that's OK?

    Read the article

  • How to encourage Windows administrators to pick up scripting

    - by icelava
    When i worked as an administrator in my first job, I was frustrated our administration processes with Windows servers were a series of point-and-clicks; we could never match the level of efficiency with the Unix servers which had a group of shell scripts to automate a lot of the work. I soon read about WSH and ADSI and wasted no time learning just how much automation I was able to achieve with scripting. There was a huge problem though - almost none of my Windows colleagues were really interested in learning scripting. They seemed happy with the manually mouse-clicking chores and were never excited at the prospect of using scripts to do the work on their behalf. I struggled to convince them to pick up scripting skills despite the evident increases in efficiency. I left that job in pursuit of a full-time software development career thereafter. Almost a decade on working in various environments and different customers, I still encounter Windows administrators mainly possessing this general "mood" where they would avoid scripting as much as possible. Despite the increasing level of accessibility Windows server technologies are opening up for scripting and automation. I am almost certain the majority of administrators are administrators precisely because they absolutely hate performing any kind of programming duties. What are some means to encourage and motivate administrators that scripting can really help them in the long run?

    Read the article

  • Remote mouse pointer not visible in VNC

    - by aef
    I used VNC desktops as a kind of collaboration server, as shared planning and pair programming environment for a long time. Now my latest iteration uses a KVM guest running Fedora 17 "Beefy Miracle", the Cinnamon desktop environment and an X11VNC server. The X11VNC server is automatically started with the desktop environment using the following command: x11vnc -localhost -many -shared -display :0 -bg My problem is that depending on the VNC client, the mouse pointer of the remote system which is shown through VNC is not synchronized to my client. I really need this, so I can see what my partner is doing on the desktop. When using Vinagre 3.2.1 on Ubuntu Oneiric Ocelot (11.10) or Vinagre 2.3.0.3 on Debian Squeeze (6.0) and I don't have my local mouse pointer inside the VNC view, I cannot see the mouse pointer of my remote system, nor its movement. When using TightVNC on Windows 7, I can recognize a mouse pointer trace for very short amounts of time after moving the mouse, but it is not clearly visible. Using UltraVNC on Windows 7 the mouse pointer is clearly visible all the time. With Gnome 2 I never had any problems with remote pointer synchronization, using exactly the same clients. I suspect this could have something to do with Cinnamon's dependency on 3D acceleration. On the other hand, it doesn't change anything to start Cinnamon's fallback environment Cinnamon 2D. Update: Same effect when I use Gnome 3.

    Read the article

  • Adding 2nd DC to the domain from a different subnet over VPN.

    - by EagerToLearn
    I'm in the process of adding a second DC to our domain and just want to make sure I have all the steps right before proceeding. Info: DC1 is 2008 R2 Standard. DC2 is 2008 R2 Standard. Network1 is 192.168.39.x/24 Network2 is 10.0.0.x/24 VPN is Sonicwall. The 2 DC's will be at two different sites, but the networks are connected by hardware VPN. (Sonicwall). The main DC server will be on the 192.168.39.0/24 network. The 2nd DC will be on 10.0.0.0/24. Here are the steps I plan to take; please let me know if I'm missing anything. Part 1: AD Sites and Services on DC1, create a new site and subnet for DC2. (Or should I create a new one for both?) (Can I use the default IPSiteLink and not change anything in there other than refresh timer?) Part 2: Point the DNS of DC2 to DC1. Run /forestprep and /domainprep (on both, or just DC1?). Dcpromo and select "Additional Domain Controller for Existing Domain". Then continue with normal steps with default locations for databases. EDIT: Didn't realize this was like reddit and required two skipped lines to skip one :P EDIT 2: When DCPromo-ing DC2, do I need to have "Append primary and connection specific DNS" and "Append parent suffixes of the primary DNS suffix" checked?

    Read the article

  • How to reject messages to unknown user in sendmail cooperating with MS-Exchange?

    - by user71061
    Hi! I have an MS Exchange 2003 configured as a mail server for an organization. As this server is located in this organization internal network and I don't want to expose it directly over internet, I have second server - linux box with sendmail - configured as intelligent relay (it accept all messages from internet addressed to @my_domain, and forward it to internal Exchange serwer, and accepts all messages from this internal Exchange server and forward it over internet). This configuration work's fine, but I want to eliminate messages addressed to not exiting users as early as possible. Good solution could be Enabling on Exchange server function of filtering recipients together with "tar pitting", but in my case this dosn't solve problem, because before any message reach my Exchange server (which could eventually reject it), it has to be already accepted by sendmail server, sitting in front of this Exchange server. So, I want to configure my sendmail server in such a way, that during initial SMTP conversation it could query somehow my Exchange server checking whether recipient address is valid or not, and based on result of this query, accept or reject (possibly with some delay) incoming message in a very early phase. In fact, I have already solved this issue by writing my own, simple sendmail milter program which checks recipient address against text file with list of valid addresses. But this solution is not satisfying me any longer, because it requires frequent updates of this file, and due to lack of time/motivation/programming skills, I don't want to cope further with my source code, adding to it functionality of querying my Exchange server. Maybe I can achieve desired effect by configuring any component of already available linux software. Any ideas?

    Read the article

  • Power issues Foxconn Barebones kit

    - by alpha1
    I have a Foxconn R20D2 bought about a year and a half ago. It ran fine for a while and then around last summer it started having power issues. I chalked it up to changes in electric current due to the overwhelmed grid when people turn on their AC units, but this problem has stayed for all year, shutting off randomly, shutting off when i turn on a vacuum and similar problems. Now that its summer again, the box basically sits there all day cycling itself, and now has gotten to the point it tried to boot and after 3 seconds, fails, shuts off and tried again. I know its power related, it runs opensuse linux and there are never any shutdown logs or anything of that sort. As the weather got hotter i noticed it happening more and more, and it most often happened in the morning, i presume as people woke up and turn on the AC. The power supply is a Chennel well technology co LTD model DSL-150. 150W max output. Its an intel atom dual core, with 2 sata drives, no CD/floppy etc, recently upgrades from 2 to 4gb of ram. It runs at 104 degrees Fahrenheit all the time almost. Any way i can test the power supply or anything else to try to fix it? Im a software guy, not hardware so im at a complete loss here, thanks for all assistance you can provide! EDIT: The switch on the back that says 230 or 115 is set to 230. If im in the USA, could that be causing the problems?

    Read the article

  • SQL Server performance on VSphere 4.0

    - by Charles
    We are having a performance issue that we cannot explain with our VMWare environment and I am hoping someone here may be able to help. We have a web application that uses a databases backend. We have an SQL 2005 Cluster setup on Windows 2003 R2 between a physical node and a virtual node. Both physical servers are identical 2950's with 2x Xeaon x5460 Quad Core CPUs and 64GB of memory, 16GB allocated to the OS. We are utilizing an iSCSI San for all cluster disks. The problem is this, when utilizing the application under a repeated stress testing that adds CPUs to the cluster nodes, the Physical node scales from 1 pCPU to 8 pCPUs, meaning we see continued performance increases. When testing the node running Vsphere, we have the expected 12% performance hit for being virtual but we still scale from 1 vCPU to 4 vCPUs like the physical but beyond this performance drops off, by the time we get to 8 vCPUs we are seeing performance numbers worse than at 4 vCPUs. Again, both nodes are configured identically in terms of hardware, Guest OS, SQL Configurations etc and there is no traffic other than the testing on the system. There are no other VMs on the virtual server so there should be no competition for resources. We have contacted VMWare for help but they have not really been any suggesting things like setting SQL Processor Affinity which, while being helpful would have the same net effect on each box and should not change our results in the least. We have looked at all of VMWare's SQL Tuning guides with regards to VSphere with no benefit, please help!

    Read the article

  • debian 6 losing a large amount of packets

    - by Sc0rian
    I have a rather strange problem. We covered all the obvious hardware related issues (different nic, eth cable and switch) however I cannot seem to stop eth dropping packets. I have 4 servers all exactly the same. driver: e1000e version: 1.2.20-k2 firmware-version: 1.8-0 bus-info: 0000:06:00.0 They are all running the latest kernel(2.6.32-5-amd64). However they do this: RX packets:17073870634 errors:0 dropped:14147208 overruns:0 frame:0 another server: eth0 Link encap:Ethernet HWaddr e0:69:95:05:2f:cb inet addr:10.10.10.86 Bcast:10.10.10.255 Mask:255.255.255.0 UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:5455209277 errors:0 dropped:375445 overruns:0 frame:0 TX packets:3666134366 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:6688414486673 (6.0 TiB) TX bytes:1611812171539 (1.4 TiB) Interrupt:20 Memory:d0600000-d0620000 eth1 Link encap:Ethernet HWaddr 00:1b:21:b7:7a:ce inet addr:10.10.0.86 Bcast:10.10.0.255 Mask:255.255.255.0 UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:15473695728 errors:0 dropped:5808325 overruns:0 frame:0 TX packets:20112364421 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:9192378766434 (8.3 TiB) TX bytes:20216368266761 (18.3 TiB) Interrupt:17 Memory:d0280000-d02a0000 A massive amount of dropped packets. I have tried to load on the latest driver, 1.9.5. This did nothing. I'm not sure what else to do.

    Read the article