Search Results

Search found 1668 results on 67 pages for 'legacy'.

Page 7/67 | < Previous Page | 3 4 5 6 7 8 9 10 11 12 13 14  | Next Page >

  • FoxPro 2.6 DOS on Windows 7 64-bit

    - by Rolando
    I support a company that has a very old, mission critical, FoxPro for DOS 2.6 (FPD) application. For variuos reasons the company didn't adapt/migrate their app, which, ironically, has been running even better under Windows XP (and 32-bit Win7) because the OS allowed new features like more reliable networking, distributed printing, email integration. Unfortunately for this company, most new machines now come with a 64-bit version of Windows 7, which is incompatible with their FPD app. I know this time the writing is on the wall: the only long-term solution is to migrate their app. But I wonder if anyone can suggest a temporary alternative path, which doesn't involve either: a) downgrade 64-bit Windows to 32-bit, or b) run the app on a virtualized 32-bit XP Thanks! PS: Happy New Year!!!

    Read the article

  • Second video card (PCI) under Windows 7

    - by dbkk101
    I'm trying to get an old PCI video card (Diamond Stealth 2500) along with a normal PCI-E video card. In BIOS, there is a setting to switch between PEG/PCI or PCI/PEG on startup (PEG is PCI-E Graphics). When I use PCI/PEG only the old PCI card works, when I use the other one, only the new PEG card works. In PEG/PCI mode, Windows 7 recognizes the card and shows it in Device Manager as Standard VGA adapter, but it shows a warning for the device ("This device cannot start. (Code 10)").

    Read the article

  • FoxPro 2.6 DOS on Windows 7 64-bit

    - by Rolando
    I support a company that has a very old, mission critical, FoxPro for DOS 2.6 (FPD) application. For variuos reasons the company didn't adapt/migrate their app, which, ironically, has been running even better under Windows XP (and 32-bit Win7) because the OS allowed new features like more reliable networking, distributed printing, email integration. Unfortunately for this company, most new machines now come with a 64-bit version of Windows 7, which is incompatible with their FPD app. I know this time the writing is on the wall: the only long-term solution is to migrate their app. But I wonder if anyone can suggest a temporary alternative path, which doesn't involve either: downgrade 64-bit Windows to 32-bit, or run the app on a virtualized 32-bit XP

    Read the article

  • IPv6 connections routed to IPv4 device

    - by Yvan JANSSENS
    I have an IBM 9406-250 with V5R1 and IPv4 only connectivity, and want it to be reachable over IPv6. I cannnot install an IPv6 stack on it, but I want it to be accessible by IPv6 so I can drop the requirement to VPN to my home network. I have an OpenWRT device running, which takes care of the IPv6 routing on my network and the tunnel to SIXXS, and I was wondering if it is possible to assign another IPv6 address to that device, and route it to the IPv4 IBM computer. Which software do I need for this, and how is this technique called?

    Read the article

  • Where can I download VMWare Tools for 1.x?

    - by matnagel
    Plsease can you show me where I can download the latest Version of VMWare Tools for the following Client: Server is Windows 2003 32 bit with VMWare Server 1.x Client is Windows 2003 32 bit Please can you point me to a download page. If the name is not "VmWare Tools" please also help me to choose the right file. (Yes, I know 1.x is old. We will upgrade later soon but not now.) Thank you.

    Read the article

  • Why no Win16 support in 64-bit Windows?

    - by dsimcha
    My understanding (from Wikipedia) is that the x64 instruction set supports executing 16-bit protected mode code from long mode, but cannot execute real mode code without being switched out of long mode because long mode lacks virtual 8086 mode. Therefore, it stands to reason that real mode DOS apps can't be run in Win64 w/o software emulation or dynamic translation. However, why was support for Win16 protected-mode apps excluded when support for them seems (at least at first glance) to be reasonably implementable and is included in newer versions of Win32? Was it just a matter of demand not being high enough to justify implementation costs (and the win32 version was already implemented), or is there a good technical reason?

    Read the article

  • Should a MobiTex service with a highly resilient website offer content over WAP?

    - by makerofthings7
    I'm trying to offer services over the MobiTex network (also see wiki) and want to reduce double-work. I'm trying to understand if it is a good idea to WAP enable my website. Given that WAP usage is increasing (since MMS is a hybrid of SMS + WAP), and the FCC has required every operator in the 700Mhz range to implement it I'd like to fully understand if there are benefits to the technology for certain critical applications. For example, if GPRS allows SMS traffic, voice, and Data, presumably they are handled by different Gateways. If there is another gateway for WAP traffic I would think that it would act as a backup if the data gateway was overloaded. Are there resiliency benefits to using WAP on a critical website? i.e. Content delivery (push or pull)

    Read the article

  • Career advice: I am best at what I hate most

    - by flybywire
    I think my career has entered a vicious circle which I would like to exit: I am best at what I hate most. And because I am good at that, I always receive that kind of assignments, and I do them as expected or even better. Which makes me more of an expert and brings me more similar tasks. My "expertise" is what (I think) every programmer hates: legacy systems. I can very quickly learn systems, and modify them, migrate them, extract web services from them whatever (without breaking them). Never to develop more functionality or to solve interesting or original problems. Just have that work with Java 1.4, or convert it into a rest-full service or support oracle too. I feel (and I am told) that I am highly regarded and very helpful to my company. But I hate what I do. What would you do in my place?

    Read the article

  • Is there any way to use getaddrinfo() and freeaddrinfo() and still be the program compatible with le

    - by Sam C.
    Hi, in the Winsock2 library getaddrinfo() and freeaddrinfo() was only added in Windows XP and on. I know how to replace them in legacy systems, but a conditional use depending on the Windows version won't help. The application won't start in 9x with a message saying that it was linked to a missing export in WS2_32.dll. I'm using MinGW to compile and link the code and would like to keep using it. Maybe writing those functions by myself? Thank you very much for everything.

    Read the article

  • Delete or comment out non-working JUnit tests?

    - by Chris Knight
    I'm currently building a CI build script for a legacy application. There are sporadic JUnit tests available and I will be integrating a JUnit execution of all tests into the CI build. However, I'm wondering what to do with the 100'ish failures I'm encountering in the non-maintained JUnit tests. Do I: 1) Comment them out as they appear to have reasonable, if unmaintained, business logic in them in the hopes that someone eventually uncomments them and fixes them 2) Delete them as its unlikely that anyone will fix them and the commented out code will only be ignored or be clutter for evermore 3) Track down those who have left this mess in my hands and whack them over the heads with the printouts of the code (which due to long-method smell will be sufficently suited to the task) while preaching the benefits of a well maintained and unit tested code base

    Read the article

  • Can a CWinApp be placed in a DLL?

    - by jmucchiello
    I'm updating some legacy apps to Visual Studio 10 and am in linker hell. All of these DLLs derive classes from CWinApp and use AfxGetApp() to get access to the object. When I link the DLLs I get unresolved externals that look like global static objects that would get pulled in by a normal app's main(): Shell.lib(SHELL.obj) : error LNK2001: unresolved external symbol "public: static struct CRuntimeClass const CException::classCException" (?classCException@CException@@2UCRuntimeClass@@B) Shell.lib(SHELL.obj) : error LNK2001: unresolved external symbol "public: static struct CRuntimeClass const CFrameWnd::classCFrameWnd" (?classCFrameWnd@CFrameWnd@@2UCRuntimeClass@@B) Shell.lib(SHELL.obj) : error LNK2001: unresolved external symbol "public: static class CRect const CFrameWnd::rectDefault" (?rectDefault@CFrameWnd@@2VCRect@@B) My current combination of ignore default libraries and additional libraries (the method you can easily google to find the answer to linker hell) is: msvcprtd.lib,mfc100d.lib,mfcs100d.lib,libcmtd.lib When I add nafxcwd.lib (the mfc library), these three external symbols resolve but I end up with a bunch of other duplicate symbols (requiring the use of /FORCE:MULTIPLE) and in end __argc and __argv become unresolved. So the basic question is: Can you link a DLL containing a CWinApp in VS10? How do you setup the linker to do it?

    Read the article

  • Is it possible to share a masterpage between MVC and webforms?

    - by Craig Quillen
    I am adding MVC to a project that has MANY legacy webform pages. This works fine. However, I currently have a separate masterpage for MVC and for the webforms. The two master pages produce essentially identical output. I'd really like to kill the webforms one and just use the MVC master page with all my pages and stay DRY. Not being DRY has already bitten me a couple times when I forgot to change both. I tried doing the obvious way and just pointing the webform content page's MasterPage attribute at the MVC masterpage. This throws an error saying the MVC masters only work with MVC views. This seems like it would be a pretty common problem with mixed MVC and webform projects. My MVC master isn't doing anything with ViewData, so I don't see any reason the webforms couldn't use them.

    Read the article

  • How can I sell a legacy program rewrite to the business?

    - by Wil
    We have a legacy classic ASP application that's been around since 2001. It badly needs to be re-written, but it's working fine from an end user perspective. The reason I feel like a rewrite is necessary is that when we need to update it (which is admittedly not that often) then it takes forever to go through all the spaghetti code and fix problems. Also, adding new features is also a pain since it was architect-ed and coded badly. I've run cost analysis for them on maintenance but they are willing to spend more for the small maintenance jobs than a rewrite. Any suggestions on convincing them otherwise?

    Read the article

  • How should I handle using two databases with a legacy PHP application?

    - by Toby Allen
    I have a legacy PHP application that was written in 2004 and uses MSSQL as a database backend. At this stage MSSQL is still supported by PHP but only just via a Microsoft driver. I have looked at converting to mysql via automated tools, which work quite well, but I have quite complex views which need a lot of individual work to convert. I don't have a great deal of time to do this. Many tools I wish to use and frameworks I would like to move the application to, don't support MSSQL, so I was considering adding new features using a new mysql database and wondered if anyone had opinions on the pros and cons of using two seperate database backends in a single application?

    Read the article

  • Do you know of a bleeding-edge HTML5 leveraging, legacy-ignoring JavaScript framework?

    - by Ivan
    What's the best framework (sort of jquery, extjs, etc like) to use if I'd like to intensively use all the freshest technologies of the HTML5 stack provided by modern browsers (Firefox 3.6+ (Minefield especially), Safari 4+, Chrome 4+) and have absolutely no need to support any legacy browsers (incl. no need in IE support at all, no need in Firefox prior to 3.5, etc.)? I'd like to get all the newest available goodness without having (even abstracted by a library layer) a line of code meant just fore legacy compatibility and keeping no legacy-induced things in mind. To soften the filter, taking very humble hope of such an ideally fresh framework to exist, the least (the maximum level of legacy support) I'd like to agree is not supporting IE versions older than IE8, or better just not supporting IE at all.

    Read the article

  • How do you map a composite id to a composite user type with Fluent NHibernate?

    - by gabe
    i'm working w/ a legacy database is set-up stupidly with an index composed of a char id column and two char columns which make up a date and time, respectively. I have created a icompositeusertype for the date and time columns to map to a single .NET DateTime property on my entity, which works by itself when not part of the id. i need to somehow use a composite id with key property mapping that includes my icompositeusertype for mapping to the two char date and time columns. Apparently w/ my version of Fluent NHibernate, CompositeIdentityPart doesn't have a CustomTypeIs() method, so i can't just do the following in my override: mapping.UseCompositeId() .WithKeyProperty(x => x.Id, CommonDatabaseFieldNames.Id) .WithKeyProperty(x => x.FileCreationDateTime) .CustomTypeIs<FileCreationDateTimeType>(); is something like this even possible w/ NHibernate let alone Fluent? I haven't been able to find anything on this.

    Read the article

  • What are the effects of using VS2005 to migrate from .NET 1.1

    - by andy
    Hey guys, I'm working on some legacy code for a client, involving Microsoft Content Management System (MCMS). Currently, everything is local, the code, MCMS, SQLServer, and IIS (5.x). I copied the project folder, and then opened the new copied solution in VS2005, and let it do it's conversion thing. But now nothing works. I've nnotice there have been some changes to IIS profile. What are the extent of these changes...?? Also, my VS2003 fails to recognize the Web Project?? Anyone have any idea what's going on? cheers!

    Read the article

  • How do I do a B43 Legacy install on Ubuntu 11.10?

    - by Gozzy
    I recently installed ubuntu onto an extra hard drive and everything booted correctly. However, my Linksys wireless card is not working. I went though all the forums and walk throughs and I know that I need to install the b43 legacy firmware to get the card to work. When I try to install the files, I keep getting the message in Terminal saying "No such file or directory" for every file i need to run. It's Ubuntu 11.10 on a dell optiplex gx280. Also, the "pool" file that is supposed to be on the file system is not there

    Read the article

  • Delphi - E2010 Incompatible types: 'Integer' and 'Char' - Any ideas

    - by zeencat
    I've been tasked with porting a legacy Delphi application over to C# .Net. The original delphi developer left several months before I was hired. I'm receiving the E2010 Incompatible types: 'Integer' and 'Char' error for the below method. I'm trying to compile the application within the Delphi 2007 IDE, I've been told that original application is either Delphi 4 or 5 if that helps any. I understand what the error is telling me but I don't understand why\how it is applied to the code snippet below. Any help\direction would be greatly appreciated. Thanks in advance function StrIComp_JOH_PAS_1(const Str1, Str2: PChar): Integer; var Ch1, Ch2 : Char; Offset : Integer; PStr : PChar; begin; PStr := Str1; Offset := Str2 - PStr; repeat Ch1 := Upper[PStr^]; Ch2 := Upper[PStr[Offset]]; if (Ch1 = #0) or (Ch1 <> Ch2) then Break; Inc(PStr); until False; Result := Integer(Ch1) - Integer(Ch2); end;

    Read the article

  • Method for finding memory leak in large Java heap dumps

    - by Rickard von Essen
    I have to find a memory leak in a Java application. I have some experience with this but would like advice on a methodology/strategy for this. Any reference and advice is welcome. About our situation: Heap dumps are larger than 1 GB We have heap dumps from 5 occasions. We don't have any test case to provoke this. It only happens in the (massive) system test environment after at least a weeks usage. The system is built on a internally developed legacy framework with so many design flaws that they are impossible to count them all. Nobody understands the framework in depth. It has been transfered to one guy in India who barely keeps up with answering e-mails. We have done snapshot heap dumps over time and concluded that there is not a single component increasing over time. It is everything that grows slowly. The above points us in the direction that it is the frameworks homegrown ORM system that increases its usage without limits. (This system maps objects to files?! So not really a ORM) Question: What is the methodology that helped you succeed with hunting down leaks in a enterprise scale application?

    Read the article

  • How to access SQL CE 3.5 from VB6

    - by Masterfu
    We have a .NET 3.5 SP1 application written in C# that stores data in an SQL CE 3.5 Database. We also need to access (read only) this very data from a legacy VB6 application. I don't know if this is at all possible. There are several approaches to this problem that I can think of. 1) I have read about ADOCE Connections, but this seems to be an option for embedded Visual Basic only 2) I can't seem to get a connection working using ADODB.Connection Objects like so Dim MyConnObj As New ADODB.Connection ' Microsoft.SQLSERVER.CE.OLEDB.3.5 ' Microsoft.SQLSERVER.MOBILE.OLEDB.3.0 MyConnObj.ConnectionString = "Provider=SQLOLEDB;Data Source=c:\test.sdf" MyConnObj.Open Maybe this is just a bad choice of providers? I also tried the providers that appear as comments above and different connection strings, but to no avail. Both providers are not installed on my dev machine and won't be installed on my customer's machine. 3) Maybe there is a way to use a more generic approach like ODBC? But I believe this would result in setup / deployment work, right? Does anyone have any experience with this scenario? As you can see, I am really looking for some good starting points. I also accept answers like "This is drop dead simple and so are you" as long as they come with some guiding directions ;-)

    Read the article

  • How to (unit-)test data intensive PL/SQL application

    - by doom2.wad
    Our team is willing to unit-test a new code written under a running project extending an existing huge Oracle system. The system is written solely in PL/SQL, consists of thousands of tables, hundreds of stored procedures packages, mostly getting data from tables and/or inserting/updating other data. Our extension is not an exception. Most functions return data from a quite complex SELECT statementa over many mutually bound tables (with a little added logic before returning them) or make transformation from one complicated data structure to another (complicated in another way). What is the best approach to unit-test such code? There are no unit tests for existing code base. To make things worse, only packages, triggers and views are source-controlled, table structures (including "alter table" stuff and necessary data transformations are deployed via channel other than version control). There is no way to change this within our project's scope. Maintaining testing data set seems to be impossible since there is new code deployed to the production environment on weekly basis, usually without prior notice, often changing data structure (add a column here, remove one there). I'd be glad for any suggestion or reference to help us. Some team members tend to be tired by figuring out how to even start for our experience with unit-testing does not cover PL/SQL data intensive legacy systems (only those "from-the-book" greenfield Java projects).

    Read the article

  • Seeking suggestions on redesigning the interface

    - by ratkok
    As a part of maintaining large piece of legacy code, we need to change part of the design mainly to make it more testable (unit testing). One of the issues we need to resolve is the existing interface between components. The interface between two components is a class that contains static methods only. Simplified example: class ABInterface { static methodA(); static methodB(); ... static methodZ(); }; The interface is used by component A so that different methods can use ABInterface::methodA() in order to prepare some input data and then invoke appropriate functions within component B. Now we are trying to redesign this interface for various reasons: Extending our unit test coverage - we need to resolve this dependency between the components and stubs/mocks are to be introduced The interface between these components diverged from the original design (ie. a lots of newer functions, used for the inter-component i/f are created outside this interface class). The code is old, changed a lot over the time and needs to be refactored. The change should not be disruptive for the rest of the system. We try to limit leaving many test-required artifacts in the production code. Performance is very important and should be no (or very minimal) degradation after the redesign. Code is OO in C++. I am looking for some ideas what approach to take. Any suggestions on how to do this efficiently?

    Read the article

< Previous Page | 3 4 5 6 7 8 9 10 11 12 13 14  | Next Page >