Search Results

Search found 37931 results on 1518 pages for 'computer case'.

Page 710/1518 | < Previous Page | 706 707 708 709 710 711 712 713 714 715 716 717  | Next Page >

  • What is consuming so much memory?

    - by Christopher
    Hi, I am having a few problems with my server. It is throwing up intermittant errors and running quite slow. Here is the output from top: top - 07:33:33 up 18:57, 1 user, load average: 0.00, 0.00, 0.00 Tasks: 90 total, 1 running, 82 sleeping, 7 stopped, 0 zombie Cpu(s): 0.0%us, 0.0%sy, 0.0%ni,100.0%id, 0.0%wa, 0.0%hi, 0.0%si, 0.0%st Mem: 1048576k total, 1048576k used, 0k free, 0k buffers Swap: 0k total, 0k used, 0k free, 0k cached Ordered by %MEM: PID USER PR NI VIRT RES SHR S %CPU %MEM TIME+ COMMAND 9597 root 16 0 276m 91m 15m S 0.0 8.9 0:29.38 java 9564 tomcat 15 0 249m 34m 11m S 0.0 3.4 0:11.79 java 9636 root 18 0 54804 24m 9784 S 0.0 2.4 0:02.58 httpd 26139 apache 15 0 57520 23m 5996 S 0.0 2.3 0:00.15 httpd 16264 apache 18 0 56984 23m 6104 S 0.0 2.2 0:00.21 httpd 24294 apache 15 0 57512 22m 5864 S 0.0 2.2 0:00.17 httpd 30231 apache 15 0 57272 22m 5748 S 0.0 2.2 0:00.97 httpd 32257 apache 15 0 57512 22m 5416 S 0.0 2.2 0:00.46 httpd 19947 apache 15 0 57512 22m 5320 S 0.0 2.2 0:00.19 httpd 26148 apache 15 0 56688 22m 5992 S 0.0 2.2 0:00.40 httpd 14039 apache 18 0 57000 22m 5492 S 0.0 2.2 0:00.33 httpd 6051 apache 15 0 57736 22m 5128 S 0.0 2.2 0:00.07 httpd 19937 apache 15 0 56992 22m 5400 S 0.0 2.2 0:00.14 httpd 5200 apache 15 0 56984 22m 5376 S 0.0 2.2 0:00.23 httpd 10001 apache 15 0 55636 21m 5636 S 0.0 2.1 0:01.05 httpd 11734 apache 15 0 56712 21m 4548 S 0.0 2.1 0:00.46 httpd 18193 apache 15 0 55100 20m 5508 S 0.0 2.0 0:00.24 httpd 14036 apache 15 0 55128 20m 5412 S 0.0 2.0 0:00.10 httpd 3981 apache 15 0 55128 19m 4860 S 0.0 1.9 0:00.16 httpd 7588 apache 18 0 55112 19m 4848 S 0.0 1.9 0:00.04 httpd 19768 apache 16 0 55112 19m 4844 S 0.0 1.9 0:00.02 httpd 5827 apache 15 0 55112 19m 4828 S 0.0 1.9 0:00.05 httpd 29774 apache 15 0 55112 19m 4544 S 0.0 1.9 0:00.11 httpd 6064 apache 15 0 55112 19m 4536 S 0.0 1.9 0:00.02 httpd 16253 apache 17 0 55116 19m 4532 S 0.0 1.9 0:00.01 httpd 19922 apache 15 0 55112 19m 4540 S 0.0 1.9 0:00.02 httpd 10010 apache 15 0 55100 19m 4524 S 0.0 1.9 0:00.01 httpd 18195 apache 18 0 55104 18m 3872 S 0.0 1.8 0:00.02 httpd 7361 mysql 15 0 134m 18m 6400 S 0.0 1.8 0:10.18 mysqld 19921 apache 15 0 55088 18m 3588 S 0.0 1.8 0:00.02 httpd 11967 apache 15 0 55080 18m 3584 S 0.0 1.8 0:00.00 httpd 13813 apache 15 0 55088 18m 3576 S 0.0 1.8 0:00.14 httpd 23898 apache 18 0 54968 17m 3212 S 0.0 1.7 0:00.00 httpd 13792 apache 15 0 54968 17m 3088 S 0.0 1.7 0:00.00 httpd 14083 apache 15 0 54968 17m 3088 S 0.0 1.7 0:00.00 httpd 32547 apache 15 0 54944 17m 2924 S 0.0 1.7 0:00.00 httpd 13787 apache 15 0 54944 17m 2908 S 0.0 1.7 0:00.00 httpd 3623 apache 17 0 54944 17m 2908 S 0.0 1.7 0:00.00 httpd 16024 apache 19 0 54944 17m 2860 S 0.0 1.7 0:00.00 httpd 13791 apache 15 0 54944 17m 2864 S 0.0 1.7 0:00.00 httpd 20090 named 19 0 110m 4244 2056 S 0.0 0.4 0:01.55 named 9369 cyrus 15 0 15904 3048 1720 S 0.0 0.3 0:00.24 cyrus-master 32735 root 15 0 8852 2888 2116 T 0.0 0.3 0:00.00 mysql The intermittant error I get using Firefox is: Server not found Firefox can't find the server at XXXXXXX.co. * Check the address for typing errors such as ww.example.com instead of www.example.com * If you are unable to load any pages, check your computer's network connection. * If your computer or network is protected by a firewall or proxy, make sure that Firefox is permitted to access the Web. And on other browsers, the page just loads for about 10 minutes but never appears. The only way to resolve it is to close the browser completely as the error appears to be saved in the cache. Has anyone got any ideas? Many Thanks.

    Read the article

  • Weird Network Behavior of Home Router

    - by Stilgar
    First of all I would like to apologize because what you are going to read will be long and confusing but I am fighting this issue for 3 days now and am out of ideas. At home I have the following setup 50Mbps Internet connects into a home router A 2 desktop computers connect to router A via standard FTP LAN cables including one where the cable is ~20m long. a second router B connects to router A via standard FTP LAN cable X (~20m long). several devices connect to the wireless network of router B and there are a couple of desktop computers connected to it through FTP LAN cables. For some reason computers connected to router B when it is connected via cable X have very slow Internet connection. It is like 5 times slower than what is expected. This is the actual problem I am trying to solve. Interesting facts If a computer is connected to cable X directly instead of through router B the Internet speed is just fine (up to the 50Mbps I get from the ISP). Tested with two computers. I have tried replacing router B with another router C and the problem persists. If I connect router B via another cable to the same ports with the same settings everything seems to work fine and computers connected to router B have quite fast Internet I have tested mainly via Speedtest.net but I have also achieved similar speeds when downloading a file The upload speed is quite higher than the download speed in all cases. Note that my ISP usually has higher upload speed (unless it manages to hit the 50Mbps cap) It seems like the speed when connecting through router B with cable X is reduced 4-5 times no matter what the original speed is. For example via router B I get 10Mbps speed to local servers where I get 50Mbps when connected on router A. If I use a distant server where the ISP is only able to provide 25Mbps I get 4-5Mbps on router B. WiFi is slower than LAN on both routers (which is normal) but the reduced speed is reduced proportionally for WiFi. In addition the upload speed is normally higher from the ISP and it is also reduced proportionally. I have tried two different network configurations. One where I have NAT behind NAT where router B connects to router A via the WAN port and has its own DHCP. Second where router B connects to router A via standard LAN port and has DHCP disabled. In this configuration router B serves as a switch and the Network Gateway for computers connected to router B is the internal IP address of router A. Both configurations work just fine but both manifest the reduced speed issue. pings seem to work just fine As far as I can tell none of the cables is crossed The RJ45 setup for cable X orange orange-white brown brow-white blue blue-white green green-white This is a big problem for me since cable X passes through walls and floors and is very hard to replace. I also may have gotten some of the facts wrong because I am almost going crazy with this issue and testing includes going several floors up and down the staircase. One hypothesis I came up with is that the cable is defective in such a way that the voltage from the router affects its performance. When it is connected to a computer it performs just fine but the router has less power. Related hypothesis includes the cable being affected by electricity cables in the walls when the voltage is low. (I know nothing about electricity) So any ideas what to do, what to test or what the issue may be?

    Read the article

  • Consistent PHP _SERVER variables between Apache and nginx?

    - by Alix Axel
    I'm not sure if this should be asked here or on ServerFault, but here it goes... I am trying to get started on nginx with PHP-FPM, but I noticed that the server block setup I currently have (gathered from several guides including the nginx Pitfalls wiki page) produces $_SERVER variables that are different from what I'm used to seeing in Apache setups. After spending the last evening trying to "fix" this, I decided to install Apache on my local computer and gather the variables that I'm interested in under different conditions so that I could try and mimic them on nginx. The Apache setup I've on my computer has only one mod_rewrite rule: RewriteEngine On RewriteCond %{SCRIPT_FILENAME} !-f RewriteCond %{SCRIPT_FILENAME} !-d RewriteRule ^(.*)$ /index.php/$1 [L] And these are the values I get for different request URIs (left is Apache, right is nginx): localhost/ - http://www.mergely.com/GnzBHRV1/ localhost/foo/bar/baz/?foo=bar - http://www.mergely.com/VwsT8oTf/ localhost/index.php/foo/bar/baz/?foo=bar - http://www.mergely.com/VGEFehfT/ What configuration directives would allow me to get similar values on requests handled by nginx? My current configuration in nginx is: server { listen 80; listen 443 ssl; server_name default; ssl_certificate /etc/nginx/certificates/dummy.crt; ssl_certificate_key /etc/nginx/certificates/dummy.key; root /var/www/default/html; index index.php index.html; autoindex on; location / { try_files $uri $uri/ /index.php; } location ~ /(?:favicon[.]ico|robots[.]txt)$ { log_not_found off; } location ~* [.]php { #try_files $uri =404; include fastcgi_params; fastcgi_pass unix:/var/run/php5-fpm.sock; fastcgi_index index.php; fastcgi_split_path_info ^(.+[.]php)(/.+)$; } location ~* [.]ht { deny all; } } And my fastcgi_params file looks like this: fastcgi_param PATH_INFO $fastcgi_path_info; fastcgi_param PATH_TRANSLATED $document_root$fastcgi_path_info; fastcgi_param QUERY_STRING $query_string; fastcgi_param REQUEST_METHOD $request_method; fastcgi_param CONTENT_TYPE $content_type; fastcgi_param CONTENT_LENGTH $content_length; fastcgi_param SCRIPT_NAME $fastcgi_script_name; fastcgi_param SCRIPT_FILENAME $document_root$fastcgi_script_name; fastcgi_param REQUEST_URI $request_uri; fastcgi_param DOCUMENT_URI $document_uri; fastcgi_param DOCUMENT_ROOT $document_root; fastcgi_param SERVER_PROTOCOL $server_protocol; fastcgi_param GATEWAY_INTERFACE CGI/1.1; fastcgi_param SERVER_SOFTWARE nginx/$nginx_version; fastcgi_param REMOTE_ADDR $remote_addr; fastcgi_param REMOTE_PORT $remote_port; fastcgi_param SERVER_ADDR $server_addr; fastcgi_param SERVER_PORT $server_port; fastcgi_param SERVER_NAME $server_name; fastcgi_param HTTPS $https; I know that the try_files $uri =404; directive is commented and that it is a security vulnerability but, if I uncomment it, the third request (localhost/index.php/foo/bar/baz/?foo=bar) will return a 404. It's also worth noting that my PHP cgi.fix_pathinfo in On (contrary to what some of the guides recommend), if I try to set it to Off, I'm presented with a "Access denied." message on every PHP request. I'm running PHP 5.4.8 and nginx/1.1.19. I don't know what else to try... Help?

    Read the article

  • Unmountable boot volume blue screen, what should I do?

    - by Josh
    I was trying to install an update from NVIDIA for my GTX 560, but while it was installing, my computer shut off. After a few minutes, I turned it back on. It got to the Windows boot screen and then had a blue screen error and if left on it would just keep doing that. A few details about my PC: I haven't added any new hardware or software, I'm running Windows XP Professional 32 bit and Windows XP Professional 64 bit on the same hard drive for about 2 years now. I have 2 other hard drives also, but I don't have one large enough to hold everything from my main hard drive, so formatting isn't an option. Now, as for what I've done so far: I've scanned the RAM with "memtest - 86 v3.4" and it said that it was good. I scanned the hard drive in question with chkdsk /r and it gets to 50% and tells me something along the lines of "the drive has one or more unrepairable problems". I also tried to use chkdsk on the drive I installed the new copy of Windows XP on and it got to 75% then jumped back down to 50% and stayed there (I had to reboot the pc). So, after that, I turned off auto reboot and got to read the blue screen error code and I looked it up only to find that nobody seems to have this problem, just problems close to it. The error code is 0x000000ed and I've seen a lot of these online but none that matched the detailed part of the code UNMOUNTABLE_BOOT_VOLUME 0x000000ed (0xfffffadf513c19a0, 0xffffffffc0000006, 0, 0) So, I have installed another copy of Windows XP Professional 32 bit on one of my other hard drives in hopes of accessing the data on the drive in question and when it booted it asked if I wanted chkdsk to scan the drive in question and this is what it found: file record segments 12740, 12741, 12742 and 12743 were reported unreadable. Then it says "recovering lost files" but it sits there for a few seconds and then just boots to Windows. I can't access the drive in question from Windows as far as I can tell, it just says "drive not accessible" and when I go to properties it says that the drive has 100% free space. So, after that failed I didn't give up, I looked for another way to access the drive in question. I used a Ubuntu bootable disk and was able to access the drive in question without any problems. However, I can't access the registry editor because it's a .exe file and that won't load from Ubuntu. I made a copy of the "Windows" folder and put it on one of my other drives and that's where I'm stuck at now. I'm sure my drive works fine, I know chkdsk can't fix the problem with it and I know what caused the problem in the first place for the most part, but I don't know what to do about it. I have a laptop that I can use to download and burn disks if needed and I also have the other copy of Windows XP Professional 32 bit that I can use that's installed on the computer in question (so I know it's not a hardware issue). I'm pretty sure it's a driver issue or the update was editing the registry when it shut off and left me when a broken registry. I've tried accessing C:\Windows\System32\CONFIG only to find that the Windows XP disk repair option can't even access the files on the drive in question. It seems I'll need to be able to do everything from Ubuntu unless there is something I haven't tried with the Windows XP disk. I didn't install the update on Windows XP 64 bit but yet it also has the same blue screen error (that's where the error code above came from but I haven't checked to see if they are the same). They both stopped working at the same time, so I assume it's one problem causing both to not work.

    Read the article

  • RAID and Partitions, guidance Needed

    - by beauregarde
    Alright I have a Biostar TA790GX3A2+ Mobo 2x Seagate 750Gb Hard drive (with 2 different speeds) an X4 9750 A GeForce 9800GT and 2GB RAM Hardware Specs link text I want to configure my computer with partitions in various RAID arrays. The Partitions I know i want (disk letters are mostly for reference here) C: XP Boot D: XP Swap E: XP Run F: Games G: Data The Partitions I think I want (repeat caveat) H: small FAT for Win Legacy and DOS I: Linux J: Linux Swap K-?M?: Other Linux /whatever partitions N & O: Attic for D1 and D2 What I'd like to do, is have C: written on Disk 1 (D1),.. D: on D2,.. E: and F: striped on D1 & D2,.. G: mirrored or D1 & D2,.. I: on D2 (so i can just switch disc boot priority to open in Ubuntu),.. J: on D1,.. and H: somewhere low on D1 I am inexperienced with VMs, so i am unsure as to whether those run out of XP, or whether i need to reserve a primary partition for them. However, I think they would be preferable for testing new OS's to scheduling a partition for the same purpose. I'm also not married to XP, but -64 IS pretty important to me. QUestion Time 1) Ignoring the irrationality of it all, is such a configuration possible? If not, can some pseudo-approximation be achieved? 2) My RAID is software, isnt it? 3) How much should I short a 750GB HD? And should i use that space for my attics, or for my attics and something else, or for something else (.iso's perhaps?)? 4) if XP is striped on D1 & D2, will that interfere egregiously with my Swap writes on D2? If so, would striping both XP and Swap relieve (or at least mitigate) that issue? Should XP and Swap just be written normally on 2 different HDs? 5) Should I keep DL's and Drivers on E: (XP Run), F: (Games), or elsewhere? 6) Is 4GB enough for C:? 7) Is 30GB enough (or too much) for E:? 8) How much to reserve for the Linux and sub-Linux partitions? Also, where on the platter do you think i should put them? 9) Am I a fool to use FAT16 instead of FAT32 for H: because I'd rather run 95 than 98SE? If not, do you think 2GB or 4GB? 10) I cant predict what my Max Commit Charge will be, so recommendations for Pagefile size? 5GB? 12GB? 11) VMs, where do I run them? do they exacerbate anything? Would it be better to just emulate Linux, 95, and DOS? EC) What havent I considered that I really should? Notes: computer is mostly for playing games and watching media, though I wouldnt rule out the use of particularly blah-intensive anything.

    Read the article

  • Multiple Homed Windows 2008 Server / Windows 7 Client

    - by Daniel Scott
    I have a small Windows 2008 network, with some Windows 7 clients. The clients are both laptops with docking stations and I would like them to communicate with the Windows 2008 server (for filesharing) through the wired network whilst they're docked. Internet connectivity for all machines (clients and server) is via a Wireless LAN, so the wireless adapter in the Windows 7 clients stays active while they're docked. When the laptops are un-docked, it would be nice to still be able to contact the windows 2008 server for print sharing (and slower file sharing) - hence the server also being on the wireless LAN. The windows 2008 server is running Active Directory, DHCP and DNS. It controls DHCP leases on the wired network and holds the DNS records for "myserver.mycompany.local", which is what the filesharing clients connect to. Ideally I'd like the DNS records to return the wired IP first so that this is the address that the laptops will attempt initially - but there doesn't seem to be a way to do that? At present the server's IP on the wireless LAN comes out of an nslookup above the wired Lan IP. The multi-homing works perfectly - but in the wrong order! Switch on the wireless lan and ping myserver and it goes to the wireless IP. Disable the wireless on the client and do the same ping again and after a couple of seconds it starts pinging the wired address. Does anyone have any suggestions on how to make this work in a predictable order? - or even if it can work. Alternative 1? If it can't work, then would this work: Remove the wireless adapter from the server, put a wireless router/bridge on the wired network (set up to route to/from the wireless LAN's subnet), then configure the clients with two routes to the (now) single IP of the server with metrics favouring direct communication over the wired LAN first? Alternative 2? Should I instead single-home the laptops so all of their connectivity is via the wired-LAN while they're docked? (and route via the windows 2008 server - or a dedicated wireless bridge/router)? My concern here is that I'd like undocking to be seamless - and if the clients are in the middle of downloading something from the internet I wouldn't want whatever they're doing interupted as they switch IP addresses onto the Wireless network. Perhaps this isn't the case and I'm concerned over nothing? Any thoughts? :) UPDATE I seem to have cracked it (at least DNS entries come out in the order I hope for - and pinging the server with various combinations of wired, wireless and both interfaces enabled uses the IP I want) ... I set the binding order of the NICs on the Server (which is acting as Domain Controller, DHCP and DNS server) so that the Wired NIC is before the Wireless adapter. (Start -- type "Network Interfaces" -- Select "View Network Connections" -- Press Alt to show classic dropdown menus -- Advanced -- Advanced Settings) Now, an nslookup (from the client) of the server's hostname returns the Wired IP first, followed by the Wireless IP. The wired IP now seems to be used whenever it's contactable. Incidentally, the metrics on the wired and wireless routes (on the client) also favour the wired LAN (based on Windows' automatically assigned metrics) - but this was always the case, even when I was having trouble getting the wired IP to be "favoured". I'm not entirely sure if this is coincidence - or if a DNS server running on Windows, handing back IP addresses for itself does actually take the binding order of it's own network interfaces into account? It would be interesting to hear from someone who can confirm or deny that (or confirm that the binding order on the server plays a role for some other reason?)

    Read the article

  • Remote Desktop failed logon event 4625 not logging correctly on 2008 Terminal Services server

    - by Zone12
    When I use the new remote desktop with ssl and try to log on with bad credentials it logs a 4625 event as expected. The problem is, it doesn't log the ip address, so I can't block malicious logons in our firewall. The event looks like this: <Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event"> <System> <Provider Name="Microsoft-Windows-Security-Auditing" Guid="{00000000-0000-0000-0000-000000000000}" /> <EventID>4625</EventID> <Version>0</Version> <Level>0</Level> <Task>12544</Task> <Opcode>0</Opcode> <Keywords>0x8010000000000000</Keywords> <TimeCreated SystemTime="2012-04-13T06:52:36.499113600Z" /> <EventRecordID>467553</EventRecordID> <Correlation /> <Execution ProcessID="544" ThreadID="596" /> <Channel>Security</Channel> <Computer>ontheinternet</Computer> <Security /> </System> <EventData> <Data Name="SubjectUserSid">S-1-0-0</Data> <Data Name="SubjectUserName">-</Data> <Data Name="SubjectDomainName">-</Data> <Data Name="SubjectLogonId">0x0</Data> <Data Name="TargetUserSid">S-1-0-0</Data> <Data Name="TargetUserName">notauser</Data> <Data Name="TargetDomainName">MYSERVER-PC</Data> <Data Name="Status">0xc000006d</Data> <Data Name="FailureReason">%%2313</Data> <Data Name="SubStatus">0xc0000064</Data> <Data Name="LogonType">3</Data> <Data Name="LogonProcessName">NtLmSsp</Data> <Data Name="AuthenticationPackageName">NTLM</Data> <Data Name="WorkstationName">MYSERVER-PC</Data> <Data Name="TransmittedServices">-</Data> <Data Name="LmPackageName">-</Data> <Data Name="KeyLength">0</Data> <Data Name="ProcessId">0x0</Data> <Data Name="ProcessName">-</Data> <Data Name="IpAddress">-</Data> <Data Name="IpPort">-</Data> </EventData> </Event> It seems because the logon type is 3 and not 10 like the old rdp sessions, the ip address and other information is not stored. The machine I am trying to connect from is on the internet and not on the same network as the server. Does anyone know where this information is stored (and what other events are generated with a failed logon)? Any help will be much appreciated.

    Read the article

  • BSOD & System Failure after trying to install a new RAM

    - by Praveen Kumar
    I have updated the question with sections, so that people won't find it difficult to read. Basic System Information Let me give a basic introduction on my system. I have a system of following configuration: Processor: Intel(R) Core(TM) i7-2600 CPU @ 3.40GHz 3.40GHz RAM: Corsair Vengeance - 4GB Single Module DDR3 Memory Kit (CMZ4GX3M1A1600C9) x 2 OS: Windows 7 Ultimate, SP1 Build 7601 HDD: 1 TB Seagate 7200 RPM The Problem It was working fine for about an year. Yesterday I planned to increase my RAM to 16 GB by putting another set of two Corsair Vengeance - 4GB Single Module DDR3 Memory Kit (CMZ4GX3M1A1600C9). I got it from an authorized reseller and also, the RAM was fitted by a service engineer only. After the RAM was fit (all the four), the system failed to start, with an error code of 0x000000f4. The complete information of it is: Problem signature: Problem Event Name: BlueScreen OS Version: 6.1.7601.2.1.0.256.1 Locale ID: 16393 Additional information about the problem: BCCode: f4 BCP1: 0000000000000003 BCP2: FFFFFA8008A39060 BCP3: FFFFFA8008A39340 BCP4: FFFFF800037C8510 OS Version: 6_1_7601 Service Pack: 1_0 Product: 256_1 Files that help describe the problem: C:\Windows\Minidump\093012-13041-01.dmp C:\Users\Praveen Kumar\AppData\Local\Temp\WER-30716-0.sysdata.xml Read our privacy statement online: http://go.microsoft.com/fwlink/?linkid=104288&clcid=0x0409 If the online privacy statement is not available, please read our privacy statement offline: C:\Windows\system32\en-US\erofflps.txt Another Problem We first thought that it was the RAM, which caused the issue. So I returned the RAMs and now my computer configuration is exactly how it was the previous day. But, following the removal of the RAM, I also had several crashes after that. One suspicious thing was with an error code c0000134: STOP: c0000135 The program can’t start because %hs is missing from your computer . Try resintalling the program to fix this problem. After reading contents from this, this and this, which were never my case, they didn't help me. But I didn't receive any more STOP c0000134 messages. But this 0x000000f4 keeps on coming. I am writing from the same system and it allows me to work for say, half an hour max. Then I hear a device disconnect sound, the one you hear in Windows 7, when a USB Mass Storage Device is plugged out. Immediately following that, my screen goes blank and I get 0x000000f4 blue screen. Okay, now I am really concerned about my Hard Disk data, but I have no clue if there is a problem with the HDD. My Question What all files do I need to submit for your reference? Can this issue be fixed? I am getting more time if I remove my RAM, clean it and then put it back. Weird! Hope I have given the necessary information to help you guys. Thanks in advance. Minidumps I have uploaded all the Minidump DMP files from C:\Windows\Minidump folder here: http://www.praveen-kumar.com/Minidumps.zip Let me know if you face any issues in accessing it. Will be able to share elsewhere. Updates 30-Sep-2012 10:15 AM IST: When I keep the system cover opened, pressed the HDD Cable well, it is allowing me to be on for about half an hour, I guess? Also, I feel that the CPU fan speed is kind of slow. It rotates at around 900 RPM, but the CPU Temperature is not more than 70° C. 30-Sep-2012 10:30 AM IST: My Modem (Beetel 220BX ADSL2+ Router) failed. I have no idea how it is related to this issue, but I thought that I need to document this too. I really have a bad day here. 30-Sep-2012 11:00 AM IST: System still running fine, with the cabinet cover open, now for about an hour. 30-Sep-2012 12:00 PM IST: I shut down the system and closed the cabinet. Started the system, and it hung after giving the password. After a few minutes, got the same 0x000000f4 error. So, while it is in the upright position, fixed the Hard Disk cable and now it is booting fine. Waiting for more observations and answers.

    Read the article

  • Unable to Mange DNS via MMC

    - by IT Helpdesk Team Manager
    When trying to access the DNS service on Microsoft Windows Server 2003 (Build 3790) domain controller/schema master via the MMC DNS snap in or locally via the DNS MMC from Administrative tools I'm getting a red "X" through the icon for the DNS Server. The inability to access DNS management via MMC happens on all domain controllers as well. We've looked at items such as the DHCP client not being started, incorrect DNS setup ( the machine points at itself and another DC ), the DNS service not running ( it is and all DNS queries via NSLOOKUP work correctly ), dslint returns the correct information and functions as expected. There is the following entry in the DNS event log: The DNS server could not initialize the remote procedure call (RPC) service. If it is not running, start the RPC service or reboot the computer. The event data is the error code. For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp. 0000: 0000051b dnscmd fails with RPC server unavailable yet RPC is started: C:\Documents and Settings\Administrator.DOMAIN>dnscmd /Info Info query failed status = 1722 (0x000006ba) Command failed: RPC_S_SERVER_UNAVAILABLE 1722 (000006ba) DCDIAG /TEST:DNS /V /E produces the following errors: Warning: no DNS RPC connectivity (error or non Microsoft DNS server is running) [Error details: 1753 (Type: Win32 - Description: There are no more endpoints available from the endpoint mapper.)] Warning: no DNS RPC connectivity (error or non Microsoft DNS server is running) [Error details: 1722 (Type: Win32 - Description: The RPC server is unavailable.)] The DNS server could not initialize the remote procedure call (RPC) service. If it is not running, start the RPC service or reboot the computer. The event data is the error code. A DNS query for _ldap._tcp.dc._msdcs. returns the correct results. All domain and ADS related activities are working except that I can't manage my DNS via MMC or dnscmd. Any thoughts or solutions would be greatly appreciated. EDIT: Adding Registry export per request: Key Name: HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Rpc Class Name: <NO CLASS> Last Write Time: 10/18/2012 - 2:29 PM Value 0 Name: DCOM Protocols Type: REG_MULTI_SZ Data: ncacn_ip_tcp Value 1 Name: UuidSequenceNumber Type: REG_DWORD Data: 0xb19bd0f Key Name: HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Rpc\ClientProtocols Class Name: <NO CLASS> Last Write Time: 3/9/2007 - 12:11 PM Value 0 Name: ncacn_np Type: REG_SZ Data: rpcrt4.dll Value 1 Name: ncacn_ip_tcp Type: REG_SZ Data: rpcrt4.dll Value 2 Name: ncadg_ip_udp Type: REG_SZ Data: rpcrt4.dll Value 3 Name: ncacn_http Type: REG_SZ Data: rpcrt4.dll Value 4 Name: ncacn_at_dsp Type: REG_SZ Data: rpcrt4.dll Key Name: HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Rpc\NameService Class Name: <NO CLASS> Last Write Time: 2/20/2006 - 4:48 PM Value 0 Name: DefaultSyntax Type: REG_SZ Data: 3 Value 1 Name: Endpoint Type: REG_SZ Data: \pipe\locator Value 2 Name: NetworkAddress Type: REG_SZ Data: \\. Value 3 Name: Protocol Type: REG_SZ Data: ncacn_np Value 4 Name: ServerNetworkAddress Type: REG_SZ Data: \\. Key Name: HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Rpc\NetBios Class Name: <NO CLASS> Last Write Time: 2/20/2006 - 4:48 PM Key Name: HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Rpc\RpcProxy Class Name: <NO CLASS> Last Write Time: 3/9/2007 - 12:11 PM Value 0 Name: Enabled Type: REG_DWORD Data: 0x1 Value 1 Name: ValidPorts Type: REG_SZ Data: pdc:100-5000 Key Name: HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Rpc\SecurityService Class Name: <NO CLASS> Last Write Time: 2/20/2006 - 4:48 PM Value 0 Name: 9 Type: REG_SZ Data: secur32.dll Value 1 Name: 10 Type: REG_SZ Data: secur32.dll Value 2 Name: 14 Type: REG_SZ Data: schannel.dll Value 3 Name: 16 Type: REG_SZ Data: secur32.dll Value 4 Name: 1 Type: REG_SZ Data: secur32.dll Value 5 Name: 18 Type: REG_SZ Data: secur32.dll Value 6 Name: 68 Type: REG_SZ Data: netlogon.dll

    Read the article

  • Why the server is not responding?

    - by par
    Hello! Our server occasionally refuses to serve a simple HTML page. This is happening during a relatively high number of requests. However, the processor is not heavy loaded and there are a lot of free memory. The error seems to occure 1 out of 50 requests in average, depending on the server load. I need to find the source of the problem and take the appropriate actions to eliminate it. I have a suspicion that the problem source is a huge number of incoming network packets. There are 5000 packets per second on average. Traffic - 2 MBits/sec Can this be the cause of the error? There is an interesting thing, in case the server fails to respond, the request string is not logged to access.log by Apache. The error is repeatable from several client computers. DNS is not involved, since I have accessed the server by the IP. I have profiled the problem case with tcpdump utility. These are the good and bad sessions traced by tcpdump. The request is the same in both experiments. Good - server returns response. Bad - no response, time-out error. ---- Bad ---- 12:23:36.366292 IP 123.45.67.890.61749 > myserver.superbservers.com.www: S 2125316338:2125316338(0) win 8192 <mss 1460,nop,wscale 2,nop,nop,sackOK> 12:23:39.362394 IP 123.45.67.890.61749 > myserver.superbservers.com.www: S 2125316338:2125316338(0) win 8192 <mss 1460,nop,wscale 2,nop,nop,sackOK> 12:23:45.365567 IP 123.45.67.890.61749 > myserver.superbservers.com.www: S 2125316338:2125316338(0) win 8192 <mss 1460,nop,nop,sackOK> -------- ---- Good ---- 12:27:07.632229 IP 123.45.67.890.63914 > myserver.superbservers.com.www: S 3581365570:3581365570(0) win 8192 <mss 1460,nop,wscale 2,nop,nop,sackOK> 12:27:10.620946 IP 123.45.67.890.63914 > myserver.superbservers.com.www: S 3581365570:3581365570(0) win 8192 <mss 1460,nop,wscale 2,nop,nop,sackOK> 12:27:10.620969 IP myserver.superbservers.com.www > 123.45.67.890.63914: S 2654770980:2654770980(0) ack 3581365571 win 5840 <mss 1460,nop,nop,sackOK,nop,wscale 6> 12:27:10.838747 IP 123.45.67.890.63914 > myserver.superbservers.com.www: . ack 1 win 4380 12:27:10.957143 IP 123.45.67.890.63914 > myserver.superbservers.com.www: P 1:213(212) ack 1 win 4380 12:27:10.957152 IP myserver.superbservers.com.www > 123.45.67.890.63914: . ack 213 win 108 12:27:10.965543 IP myserver.superbservers.com.www > 123.45.67.890.63914: P 1:630(629) ack 213 win 108 12:27:10.965621 IP myserver.superbservers.com.www > 123.45.67.890.63914: F 630:630(0) ack 213 win 108 12:27:11.183540 IP 123.45.67.890.63914 > myserver.superbservers.com.www: . ack 631 win 4222 12:27:11.185657 IP 123.45.67.890.63914 > myserver.superbservers.com.www: F 213:213(0) ack 631 win 4222 12:27:11.185663 IP myserver.superbservers.com.www > 123.45.67.890.63914: . ack 214 win 108 -------- Hoster: SuperbHosting OS: Ubuntu Server parameters: E6300 CONROE 1.86GHZ 2 X 1MB CACHE 1066 1GB DDR2 667MHZ This is a link to apache configuration file we use http://repkin5.snow.prohosting.com/apache.txt This is server-status report taken right after time-out error. http://repkin5.snow.prohosting.com/server-status.htm There are only 10 Child Servers running out of 120, so enough space for new requests. VMSTAT procs -----------memory---------- ---swap-- -----io---- -system-- ----cpu---- r b swpd free buff cache si so bi bo in cs us sy id wa 0 0 8900 725900 8468 65684 0 0 5 18 11 33 4 3 92 1

    Read the article

  • Magento hosting on a budget

    - by spa
    I have to do a setup for Magento. My constraint is primarily ease of setup and fault tolerance/fail over. Furthermore costs are an issue. I have three identical physical servers to get the job done. Each server node has an i7 quad core, 16GB RAM, and 2x3TB HD in a software RAID 1 configuration. Each node runs Ubuntu 12.04. right now. I have an additional IP address which can be routed to any of these nodes. The Magento shop has max. 1000 products, 50% of it are bundle products. I would estimate that max. 100 users are active at once. This leads me to the conclusion, that performance is not top priority here. My first setup idea One node (lb) runs nginx as a load balancer. The additional IP is used with domain name and routed to this node by default. Nginx distributes the load equally to the other two nodes (shop1, shop2). Shop1 and shop2 are configured equally: each server runs Apache2 and MySQL. The Mysqls are configured with master/slave replication. My failover strategy: Lb fails = Route IP to shop1 (MySQL master), continue. Shop1 fails = Lb will handle that automatically, promote MySQL slave on shop2 to master, reconfigure Magento to use shop2 for writes, continue. Shop2 fails = Lb will handle that automatically, continue. Is this a sane strategy? Has anyone done a similar setup with Magento? My second setup idea Another way to do it would be to use drbd for storing the MySQL data files on shop1 and shop2. I understand that in this scenario only one node/MySQL instance can be active and the other is used as hot standby. So in case shop1 fails, I would start up MySQL on shop2, route the IP to shop2, and continue. I like that as the MySQL setup is easier and the nodes can be configured 99% identical. So in this case the load balancer becomes useless and I have a spare server. My third setup idea The third way might be master-master replication of MySQL databases. However, in my optinion this might be tricky, as Magento isn't build for this scenario (e.g. conflicting ids for new rows). I would not do that until I have heard of a working example. Could you give me an advice which route to follow? There seems not one "good" way to do it. E.g. I read blog posts which describe a MySQL master/slave setup for Magento, but elsewhere I read, that data might get duplicated when the slave lags behind the master (e.g. when an order is placed, a customer might get created twice). I'm kind of lost here.

    Read the article

  • Is it possible to repair a Cisco 3500 XL (3548) switch with POST Error messages?

    - by Alex
    I've got an old Cisco 3500 XL, and it seems to have hardware issues. I've loaded the latest IOS and cleared all config. Does anyone have any experience fixing the switch core? I'm a reasonably competent SMD solderer, can I replace/reflow some chips? I've checked the power supply voltages and it's all within tolerance, and no visible signs of any component damage. Some chips are hot to the touch. I understand that these were EOL as of 2007, but should have a lifetime warranty for the electronics. I don't have a Cisco support contract, so I can't file a ticket. What should I do? Console output: switch: dir flash: Directory of flash:/ 2 -rwx 1811584 <date> c3500xl-c3h2s-mz.120-5.WC17.bin 1799680 bytes available (1812992 bytes used) switch: boot Loading "flash:c3500xl-c3h2s-mz.120-5.WC17.bin"...################################################################################################################################################################################### File "flash:c3500xl-c3h2s-mz.120-5.WC17.bin" uncompressed and installed, entry point: 0x3000 executing... Restricted Rights Legend Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (c) of the Commercial Computer Software - Restricted Rights clause at FAR sec. 52.227-19 and subparagraph (c) (1) (ii) of the Rights in Technical Data and Computer Software clause at DFARS sec. 252.227-7013. cisco Systems, Inc. 170 West Tasman Drive San Jose, California 95134-1706 Cisco Internetwork Operating System Software IOS (tm) C3500XL Software (C3500XL-C3H2S-M), Version 12.0(5)WC17, RELEASE SOFTWARE (fc1) Copyright (c) 1986-2007 by cisco Systems, Inc. Compiled Tue 13-Feb-07 15:04 by antonino Image text-base: 0x00003000, data-base: 0x00352924 Initializing C3500XL flash... flashfs[1]: 1 files, 1 directories flashfs[1]: 0 orphaned files, 0 orphaned directories flashfs[1]: Total bytes: 3612672 flashfs[1]: Bytes used: 1812992 flashfs[1]: Bytes available: 1799680 flashfs[1]: flashfs fsck took 3 seconds. flashfs[1]: Initialization complete. ...done Initializing C3500XL flash. C3500XL POST: System Board Test: Passed C3500XL POST: Daughter Card Test: Passed C3500XL POST: CPU Buffer Test: Passed C3500XL POST: CPU Notify RAM Test: Passed C3500XL POST: CPU Interface Test: Passed C3500XL POST: Testing Switch Core: Passed Error with Switch Core BIST test Phase 0. Returns: Test Complete Low : 0x0FFFFFFF, Test Complete High : 0xFFFFFFFE Test Phase Low : 0x00000040, Test Phase High : 0x00000000 Test Phase Third : 0x00000000, Test Complete Third : 0x000001F8 C3500XL POST FAILURE: Testing Switch Core: Failed C3500XL POST FAILURE: Testing Buffer Table: Failed C3500XL POST FAILURE: Data Buffer Test: Failed C3500XL POST FAILURE: Configuring Switch Parameters: Failed C3500XL POST FAILURE: Switch Core BIST failed. C3500XL POST FAILURE: Cannot test Modules due to failure of Switch Core POST Del Mar Failure (0th Del Mar): req system failed to init C3500XL POST FAILURE: C3500XL POST FAILURE: ATM: required system failed to init C3500XL POST: Ethernet Controller Test: Passed C3500XL POST FAILURE: MII Test: Failed C3500XL POST FAILURE: Error waiting for Ethernet Controller and SW_PARAMS C3500XL POST FAILURE: Initialization/POST failed C3500XL POST FAILURE: AT: Failing because system POST failed Exception (8192)! Debug Exception (Could be NULL pointer dereference) CPU Register Context: Vector = 0x00002000 PC = 0x000F36F4 MSR = 0x00029200 CR = 0x22000024 LR = 0x000F6964 CTR = 0x001DE46C XER = 0x00000000 R0 = 0x00000000 R1 = 0x004E2580 R2 = 0x00000000 R3 = 0x00000000 R4 = 0x00000001 R5 = 0x00000000 R6 = 0x004E2718 R7 = 0x004E2718 R8 = 0x00000008 R9 = 0x00000000 R10 = 0x0000FFFF R11 = 0x00480000 R12 = 0x42000024 R13 = 0x00000000 R14 = 0x00000000 R15 = 0x00000000 R16 = 0x00000000 R17 = 0x00000000 R18 = 0x00000000 R19 = 0x00000000 R20 = 0x00000000 R21 = 0x00000000 R22 = 0x00000000 R23 = 0x00000000 R24 = 0x00000000 R25 = 0x00000020 R26 = 0x004E2718 R27 = 0x004E2718 R28 = 0x00000020 R29 = 0x00002513 R30 = 0x00000001 R31 = 0x00000000 Stack trace: PC = 0x000F36F4, SP = 0x004E2580 Frame 00: SP = 0x004E25A0 PC = 0x40000016 Frame 01: SP = 0x004E2618 PC = 0x000F6964 Frame 02: SP = 0x004E26A8 PC = 0x000F76DC Frame 03: SP = 0x004E26C8 PC = 0x000E8114 Frame 04: SP = 0x004E26F0 PC = 0x001F5BF8 Frame 05: SP = 0x004E2710 PC = 0x001F5CF4 Frame 06: SP = 0x004E2748 PC = 0x0023F4DC Frame 07: SP = 0x004E2750 PC = 0x0023E650 Frame 08: SP = 0x004E27C8 PC = 0x0023E89C Frame 09: SP = 0x004E27E0 PC = 0x0028AF34 Frame 10: SP = 0x004E27E8 PC = 0x001E38F8 Frame 11: SP = 0x004E2808 PC = 0x001E39A8 Frame 12: SP = 0x004E2820 PC = 0x0014E220 Frame 13: SP = 0x004E28C8 PC = 0x0014E39C Frame 14: SP = 0x00000000 PC = 0x001EB510

    Read the article

  • Duplicate DNS Zones (Error 4515 in Event Log )

    - by Campo
    I am getting these two error in the DNS Event log (errors at end of question). I have confirmed I do have duplicate zones. I am wondering which ones to delete. The DomainDNSZone contains all of our DNS records but it does not have the _msdcs zone.... that is in the ForestDNSZone with the duplicates that are not in use. here is a picture of that 3 Questions. I understand the advantages of having DNS in the ForestDNSZone. so... Why is DNS using the DomainDNSZone and is that acceptable considering _msdcs... is in the ForestDNSZone? If so, should I just delete the DC=1.168.192.in-addr.arpa and DC=supernova.local from the ForestDNSZone? Or should I try to get those to be the ones in use? What are those steps? I understand how to delete. That is simple but if i must move zones some info would be appreaciated there. Just to confirm. from my understanding. I can delete the two duplicates in the ForestDNSZone and leave the _msdcs.supernova.local as thats required there. This will resolve the erros I see. Just fyi when I look in those folders from the ForestDNSZone they have just 2 and 1 entries respectively. So obviously not in use compared to the others. I am pretty sure I understand the steps to complete this. But if you would like to provide that info, bonus points! Event Type: Warning Event Source: DNS Event Category: None Event ID: 4515 Date: 1/4/2011 Time: 2:14:18 PM User: N/A Computer: STANLEY Description: The zone 1.168.192.in-addr.arpa was previously loaded from the directory partition DomainDnsZones.supernova.local but another copy of the zone has been found in directory partition ForestDnsZones.supernova.local. The DNS Server will ignore this new copy of the zone. Please resolve this conflict as soon as possible. If an administrator has moved this zone from one directory partition to another this may be a harmless transient condition. In this case, no action is necessary. The deletion of the original copy of the zone should soon replicate to this server. If there are two copies of this zone in two different directory partitions but this is not a transient caused by a zone move operation then one of these copies should be deleted as soon as possible to resolve this conflict. To change the replication scope of an application directory partition containing DNS zones and for more details on storing DNS zones in the application directory partitions, please see Help and Support. For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp. Data: 0000: 89 25 00 00 %.. AND Event Type: Warning Event Source: DNS Event Category: None Event ID: 4515 Date: 1/4/2011 Time: 2:14:18 PM User: N/A Computer: STANLEY Description: The zone supernova.local was previously loaded from the directory partition DomainDnsZones.supernova.local but another copy of the zone has been found in directory partition ForestDnsZones.supernova.local. The DNS Server will ignore this new copy of the zone. Please resolve this conflict as soon as possible. If an administrator has moved this zone from one directory partition to another this may be a harmless transient condition. In this case, no action is necessary. The deletion of the original copy of the zone should soon replicate to this server. If there are two copies of this zone in two different directory partitions but this is not a transient caused by a zone move operation then one of these copies should be deleted as soon as possible to resolve this conflict. To change the replication scope of an application directory partition containing DNS zones and for more details on storing DNS zones in the application directory partitions, please see Help and Support. For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp. Data: 0000: 89 25 00 00 %..

    Read the article

  • Varnish VCL - Regular Expression Evaluation

    - by Hugues ALARY
    I have been struggling for the past few days with this problem: Basically, I want to send to a client browser a cookie of the form foo[sha1oftheurl]=[randomvalue] if and only if the cookie has not already been set. e.g. If a client browser requests "/page.html", the HTTP response will be like: resp.http.Set-Cookie = "foo4c9ae249e9e061dd6e30893e03dc10a58cc40ee6=ABCD;" then, if the same client request "/index.html", the HTTP response will contain a header: resp.http.Set-Cookie = "foo14fe4559026d4c5b5eb530ee70300c52d99e70d7=QWERTY;" In the end, the client browser will have 2 cookies: foo4c9ae249e9e061dd6e30893e03dc10a58cc40ee6=ABCD foo14fe4559026d4c5b5eb530ee70300c52d99e70d7=QWERTY Now, that, is not complicated in itself. The following code does it: import digest; import random; ##This vmod does not exist, it's just for the example. sub vcl_recv() { ## We compute the sha1 of the requested URL and store it in req.http.Url-Sha1 set req.http.Url-Sha1 = digest.hash_sha1(req.url); set req.http.random-value = random.get_rand(); } sub vcl_deliver() { ## We create a cookie on the client browser by creating a "Set-Cookie" header ## In our case the cookie we create is of the form foo[sha1]=[randomvalue] ## e.g for a URL "/page.html" the cookie will be foo4c9ae249e9e061dd6e30893e03dc10a58cc40ee6=[randomvalue] set resp.http.Set-Cookie = {""} + resp.http.Set-Cookie + "foo"+req.http.Url-Sha1+"="+req.http.random-value; } However, this code does not take into account the case where the Cookie already exists. I need to check that the Cookie does not exists before generating a random value. So I thought about this code: import digest; import random; sub vcl_recv() { ## We compute the sha1 of the requested URL and store it in req.http.Url-Sha1 set req.http.Url-Sha1 = digest.hash_sha1(req.url); set req.http.random-value = random.get_rand(); set req.http.regex = "abtest"+req.http.Url-Sha1; if(!req.http.Cookie ~ req.http.regex) { set req.http.random-value = random.get_rand(); } } The problem is that Varnish does not compute Regular expression at run time. Which leads to this error when I try to compile: Message from VCC-compiler: Expected CSTR got 'req.http.regex' (program line 940), at ('input' Line 42 Pos 31) if(req.http.Cookie !~ req.http.regex) { ------------------------------##############--- Running VCC-compiler failed, exit 1 VCL compilation failed One could propose to solve my problem by matching on the "abtest" part of the cookie or even "abtest[a-fA-F0-9]{40}": if(!req.http.Cookie ~ "abtest[a-fA-F0-9]{40}") { set req.http.random-value = random.get_rand(); } But this code matches any cookie starting by 'abtest' and containing an hexadecimal string of 40 characters. Which means that if a client requests "/page.html" first, then "/index.html", the condition will evaluate to true even if the cookie for the "/index.html" has not been set. I found in bug report phk or someone else stating that computing regular expressions was extremely expensive which is why they are evaluated during compilation. Considering this, I believe that there is no way of achieving what I want the way I've been trying to. Is there any way of solving this problem, other than writting a vmod? Thanks for your help! -Hugues

    Read the article

  • Cannot create zpool, how to get rid of intel raid volume?

    - by nagylzs
    This is a FreeBSD 9.1 amd64 computer. It has 5 disks installed. The ada0 and ada1 disks are used with a hw raid to provide the root filesystem: root@gw:/home/gandalf # ls /dev | grep ada ada0 ada1 ada2 ada3 ada4 root@gw:/home/gandalf # zpool status pool: zroot state: ONLINE scan: none requested config: NAME STATE READ WRITE CKSUM zroot ONLINE 0 0 0 raid/r0s1a ONLINE 0 0 0 errors: No known data errors I want to create a raidz pool for the remaining disks: root@gw:/home/gandalf # zpool create -f data raidz1 ada2 ada3 ada4 cannot create 'data': one or more devices is currently unavailable root@gw:/home/gandalf # dmesg | grep ada2 ada2 at ata4 bus 0 scbus6 target 0 lun 0 ada2: <WDC WD20EARS-00MVWB0 51.0AB51> ATA-8 SATA 2.x device ada2: 300.000MB/s transfers (SATA 2.x, UDMA5, PIO 8192bytes) ada2: 1907729MB (3907029168 512 byte sectors: 16H 63S/T 16383C) ada2: Previously was known as ad16 root@gw:/home/gandalf # dmesg | grep ada3 ada3 at ata5 bus 0 scbus7 target 0 lun 0 ada3: <SAMSUNG HD103UJ 1AA01118> ATA-7 SATA 2.x device ada3: 300.000MB/s transfers (SATA 2.x, UDMA5, PIO 8192bytes) ada3: 953868MB (1953523055 512 byte sectors: 16H 63S/T 16383C) ada3: Previously was known as ad18 GEOM_RAID: Intel-fb8732fa: Disk ada3 state changed from NONE to ACTIVE. GEOM_RAID: Intel-fb8732fa: Subdisk Volume0:0-ada3 state changed from NONE to ACTIVE. root@gw:/home/gandalf # dmesg | grep ada4 ada4 at ata6 bus 0 scbus8 target 0 lun 0 ada4: <TOSHIBA DT01ACA100 MS2OA750> ATA-8 SATA 3.x device ada4: 300.000MB/s transfers (SATA 2.x, UDMA5, PIO 8192bytes) ada4: 953869MB (1953525168 512 byte sectors: 16H 63S/T 16383C) ada4: Previously was known as ad20 root@gw:/home/gandalf # dmesg | grep GEOM_RAID Aha, so ada3 is already part of another raid volume? Let's see: root@gw:/home/gandalf # dmesg | grep GEOM_RAID GEOM_RAID: SiI-130628113902: Array SiI-130628113902 created. GEOM_RAID: SiI-130628113902: Disk ada0 state changed from NONE to ACTIVE. GEOM_RAID: SiI-130628113902: Subdisk SiI Raid1 Set:1-ada0 state changed from NONE to STALE. GEOM_RAID: SiI-130628113902: Disk ada1 state changed from NONE to ACTIVE. GEOM_RAID: SiI-130628113902: Subdisk SiI Raid1 Set:0-ada1 state changed from NONE to STALE. GEOM_RAID: SiI-130628113902: Array started. GEOM_RAID: SiI-130628113902: Subdisk SiI Raid1 Set:0-ada1 state changed from STALE to ACTIVE. GEOM_RAID: SiI-130628113902: Subdisk SiI Raid1 Set:1-ada0 state changed from STALE to RESYNC. GEOM_RAID: SiI-130628113902: Subdisk SiI Raid1 Set:1-ada0 rebuild start at 0. GEOM_RAID: SiI-130628113902: Volume SiI Raid1 Set state changed from STARTING to SUBOPTIMAL. GEOM_RAID: SiI-130628113902: Provider raid/r0 for volume SiI Raid1 Set created. GEOM_RAID: Intel-fb8732fa: Array Intel-fb8732fa created. GEOM_RAID: Intel-fb8732fa: Force array start due to timeout. GEOM_RAID: Intel-fb8732fa: Disk ada3 state changed from NONE to ACTIVE. GEOM_RAID: Intel-fb8732fa: Subdisk Volume0:0-ada3 state changed from NONE to ACTIVE. GEOM_RAID: Intel-fb8732fa: Array started. GEOM_RAID: Intel-fb8732fa: Volume Volume0 state changed from STARTING to DEGRADED. GEOM_RAID: Intel-fb8732fa: Provider raid/r1 for volume Volume0 created. root@gw:/home/gandalf # Yes, indeed. I want to get rid of raid/r1 completely. However, the controller was already set to "IDE" mode in the BIOS. So why it is creating a raid volume??? I have also tried overwritting the first 16k data of ada3 and reboot the computer, but it did not help. How can I delete /dev/raid/r1 ? root@gw:/home/gandalf # graid status Name Status Components raid/r0 SUBOPTIMAL ada0 (ACTIVE (RESYNC 4%)) ada1 (ACTIVE (ACTIVE)) raid/r1 DEGRADED ada3 (ACTIVE (ACTIVE)) root@gw:/home/gandalf # graid delete raid/r1 graid: Array 'raid/r1' not found. root@gw:/home/gandalf # graid delete /dev/raid/r1 graid: Array '/dev/raid/r1' not found. root@gw:/home/gandalf # Thanks

    Read the article

  • All client browsers repeatedly asking for NTLM authentication when running through local proxy server

    - by Marko
    All client browsers repeatedly asking for NTLM authentication when running through local proxy server. When pointing browsers through the local proxy to the internet, some but not all clients are being repeatedley prompted to authenticate to the proxy server. I have inspected the headers using firefox live headers as well as fiddler, and in all cases the authentication prompts happen when requesting SSL resources. an example of this would be as follows: GET http://gmail.google.com/mail/ HTTP/1.1 Accept: image/gif, image/jpeg, image/pjpeg, image/pjpeg, application/x-shockwave- flash, application/x-ms-application, application/x-ms-xbap, application/vnd.ms- xpsdocument, application/xaml+xml, */* Accept-Language: en-gb User-Agent: Mozilla/4.0 (compatible; MSIE 8.0; Windows NT 5.1; Trident/4.0; .NET CLR 1.1.4322; .NET CLR 2.0.50727; .NET CLR 3.0.4506.2152; .NET CLR 3.5.30729) Accept-Encoding: gzip, deflate Proxy-Connection: Keep-Alive Host: gmail.google.com GET http://gmail.google.com/mail/ HTTP/1.1 Accept: image/gif, image/jpeg, image/pjpeg, image/pjpeg, application/x-shockwave- flash, application/x-ms-application, application/x-ms-xbap, application/vnd.ms- xpsdocument, application/xaml+xml, */* Accept-Language: en-gb User-Agent: Mozilla/4.0 (compatible; MSIE 8.0; Windows NT 5.1; Trident/4.0; .NET CLR 1.1.4322; .NET CLR 2.0.50727; .NET CLR 3.0.4506.2152; .NET CLR 3.5.30729) Accept-Encoding: gzip, deflate Proxy-Connection: Keep-Alive Host: gmail.google.com Proxy-Authorization: NTLM TlRMTVNTUAABAAAAB7IIogkACQAvAAAABwAHACgAAAAFASgKAAAAD1dJTlhQMUdGTEFHU0hJUDc= GET http://gmail.google.com/mail/ HTTP/1.1 Accept: image/gif, image/jpeg, image/pjpeg, image/pjpeg, application/x-shockwave- flash, application/x-ms-application, application/x-ms-xbap, application/vnd.ms- xpsdocument, application/xaml+xml, */* Accept-Language: en-gb User-Agent: Mozilla/4.0 (compatible; MSIE 8.0; Windows NT 5.1; Trident/4.0; .NET CLR 1.1.4322; .NET CLR 2.0.50727; .NET CLR 3.0.4506.2152; .NET CLR 3.5.30729) Accept-Encoding: gzip, deflate Proxy-Connection: Keep-Alive Proxy-Authorization: NTLM TlRMTVNTUAADA (more stuff goes here I cut it short) Host: gmail.google.com At this point the username and password prompt has appeared in the browser, it does not matter what is typed into this box, correct credentials, random nonsense the browser does not accept anything in this box it will continue to popup. If I press cancel, I sometimes get a http 407 error, but on other occasions I click cancel the website proceeds to download and show normally. This is repeatable with some clients running through my proxy server, but in other cases it does not happen at all. In the cases where a client computer works normally, the only difference I can see is that the 3rd request for SSL resource comes back with a 200 response, see below: CONNECT gmail.google.com:443 HTTP/1.0 User-Agent: Mozilla/5.0 (compatible; MSIE 9.0; Windows NT 6.1; Trident/5.0; MALC) Proxy-Connection: Keep-Alive Content-Length: 0 Host: gmail.google.com Pragma: no-cache Proxy-Authorization: NTLM TlRMTVNTUAADAAAAGAAYAIAAAA A SSLv3-compatible ClientHello handshake was found. I have tried resetting user accounts as well as computer accounts in Active Directory. User accounts and passwords that are being used are correct and the passwords have been reset so they are not out of sync. I have removed the clients and even the proxy server from the domain, and rejoined them. I have installed a complete separate proxy server and get exactly the same problem when I point clients to a different proxy server on a different IP address.

    Read the article

  • IP Micro-outages, telephone micro-outages, and CATV micro-outages

    - by Michael Graff
    This is a long and complicated question, mostly because it has been going on for 2.5 years without a solution in sight. It also is only one-third computer related, the other two-thirds are cable TV and cable-phone related. Background I have COX Communications for a cable provider, and we get Internet, digital cable TV, and digital phone service through them. The Internet is a SB5101 right now, and has been a DPC2100 and SB5120 in the past. Same results. The phone service is provided through a telephone interface mounted on the outside of the house (not classic VoIP) and the CATV is through a Scientific Atlanta receiver without DVR. I do have a TiVo connected to the CATV box. Symptoms The CATV shows "blocking" -- sometimes very very short duration where a few blocks appear on the screen. Sometimes it lasts long enough that the video "pauses" for 2-5 seconds, and rarely but not unseen the audio also fails. The CATV decoder box shows no correctable (FEC) or uncorrectable errors. That is, all BER counters are zero for the video stream. The Internet shows "micro-outages" where it appears that sent packets are not making it out, but I continue to receive packets from local modems. That is, pings stop coming back, but I continue to see modems broadcast for DHCP, and sometimes they ask more than once. The cable modem shows no errors during this time, but cable modems lie like you would not believe. It is actually possible to unplug the coax from the modem for 20 seconds and it reports NO ERRORS to the provider's tools. The phone service cuts out for 1-3 seconds, infrequently. When this happens, I hear NOTHING (not even comfort noise) and the remote side hears a "click" as if I were getting a call waiting message. However, there is no call incoming, other than the one I'm currently on of course. Things SEEM to happen more frequently when the temperature outside swings from cold to warm, so fall/spring seems worse than summer/winter. All micro-outages occur between once or twice a day (which I could ignore) to 10 times per hour. All SNR, signal levels, noise levels, etc. show very close to optimal when measured. COX's diagnosis This is a continual pain for me. Over the last 2.5 years, they have opened, "fixed" something, and closed the tickets. They close it without confirming that it is indeed better, and when I reopen they cannot do that, but instead they open a new ticket and send yet another low-level tech out to do the same signal tests and report that all is OK. I've finally gotten a line tech who has a clue and is motivated enough to pursue this with me. We have tried things like switching the local nodes over to UPS and generator power, but this does not trigger the noise. We have tried replacing all cabling, the tap outside my house, the modem, the CATV decoder -- all without resolution. Recently they have decided it is both my computer or switch, my TiVo, and my phone that are all broken and causing this issue. My debugging steps I spent the worse day of my TV-watching life yesterday and part of today. I watched live TV without the TiVo. I witnessed blocking, but it did "feel different." and was actually more severe. Some days it is better, some days it is worse, so perhaps this was just a very bad day. Today, I connected the TiVo to my DVD player, and ran two very long movies through it. I saw no blocking at all during nearly 6 hours of video. Suggestions? Does anyone have any suggestions on what to do next? I understand perhaps only the IP side can be addressed here, but it is one of the more limiting debugging options.

    Read the article

  • Cheapest way to connect 20-24 Sata II HDDs in a budget storage server?

    - by Joe Hopfgartner
    I need to assemble a high density storage server for as cheap as possible. It's been a while for me and the last systems I integrated didn't even have Sata yet... During my Research I of course stumbled about Nexsan SATA Beast, the BackBlaze storage Pods as well as some ridiculously overpriced HP Proliant or Dell storage solutions. Finally I choose Norco cases as the way to go. My eye is set on the RPC-4020, which is a 4U 19" Rackmount case with 20 Hot Swap 3.5" SATA/SAS Hdd trays (Backplanes included) and room for two 2.5" OS drives as well as a Slim Line CD-Rom. The backplanes connect with a single SATA port for each drive, so there are 20 internal SATA ports to to be connected. They also have redundant power ports which I think is quite nice. The cheapest price I have found is 290$ + 40$ shipping. In europe the cheapest unfortunately is 370€ (500$) + 40 € shipping... A nice alternative would be the RPC-4224 which has SFF-8087 Mini SAS connectors that bundle 4 SATA trays each. But it doesn't seem to be available in Europe (where i am) anywhere. So here comes my problem: What Mainboard/Controller to choose to connect them for as cheap as possible while still having nice data rates? I have to say that the server is intended as a Storage server with 1gps connectivity and the data transfer will be distributed very evenly across all drives. I also don't require any raid functionality. This is all done at application level, I just need JBOD. So for example if I go for the RPC 4020 Model I need to connect 20 Storage + 1 OS + 1 CDROM Sata ports. I searched a bit and stumbled across this very low priced controller: http://www.intel.com/products/server/raid-controllers/SASWT4I/SASWT4I-overview.htm They sell it for 115 € here and the specs say it can control up to 122 hard discs and has 4 Mini SAS connectors. So I would use 4 Mini SAS 36pin - 4 SATA 7pin cables to connect 4 SATA drives to each port and choose a Mainboard taht has 6 SATA on board (for example this one) and hurray, I can connect my 22 SATA devices for as low as about ~ 220 EUR (cpu, ram, psu, case not counted) Question: WOULD THAT WORK? And if not, why? 2nd Question: If I go for the 4220 or 4224 Model, I have internal Mini SAS connectors. Am I right in assuming that the backplane than acts as a "SAS Expander"? And can I just plug these SAS connectors into any SAS port I can find on my controller / mainboard or are there certain requirements? I know that SATA port multipliers only work with controllers that are ready for that. But isn't this expansion already implemented in the SAS standard? I am sorry that this is a very broad question, but I really spent the last week reading up and it seems to be not so clear! Especially all the controlling hardware specifications! 3rd Question: A lot of hardware specs feature "internal channels" and "internal connectors". The connecors are the physical numbers of places where I can plug a cable in. I got that. But are the "internal channels" always the maximum numbers of physical drives that can be used in the end? Or can I enhance this further by Expanders/Fanouts? 4th and last question: What do you think about the setup so far? Do you know any good alternatives? Maby I am completely going the wrong way and some DAS would be way better? Are there any comparable chassis available in europe? Please feel free to say whatever you think is relevant to the subject!

    Read the article

  • LDAP object class violation: attribute ou not allowed in suffix?

    - by Paramaeleon
    I am about to set up a LDAP directory. It is used as a tool to communicate user permissions from a web application to WebDav file system access, e.g. adding a user to the web platform shall allow login to the file system with the same credentials. There are no other usages intended. Following this German tutorial which encourages the use of the attributes c, o, ou etc. over dc, I configured the following suffix and root: suffix "ou=webtool,o=myOrg,c=de" rootdn "cn=ldapadmin,ou=webtool,o=myOrg,c=de" Server starts and I can connect to it by LDAP Admin, which reports “LDAP error: Object lacks”. Well, there aren’t any objects yet. I now want to create the root and admin elements from shell. I created an init.ldif file: dn: ou=webtool,o=myOrg,c=de objectclass: dcObject objectclass: organization dc: webtool o: webtool dn: cn=ldapadmin,ou=webtool,o=myOrg,c=de objectclass: organizationalRole cn: ldapadmin Trying to load the file runs into an error, telling me that ou is not allowed: server:~ # ldapadd -x -D "cn=ldapadmin,ou=webtool,o=myOrg,c=de" -W -f init.ldif Enter LDAP Password: adding new entry "ou=webtool,o=myOrg,c=de" ldap_add: Object class violation (65) additional info: attribute 'ou' not allowed I am not using ou anywhere except in the suffix, so the question: Isn’t it allowed here? What is allowed here? Here is my answer. I am not allowed to post it as answer for 8 hours, so don’t mind that it is part of the question by now. I will move it outside some day, if I don’t forget to do so. There are numberous dependencies for the creation of elements, and error messages are rather confusing if you don’t know of the concept. The objectclass isn’t necessarily dcObject for the databases’ root node, as it is likely to guess when you read several tutoriales. Instead, it must correspond to the object’s type: Here, for a name starting with ou=, it must be organizationalUnit. I found this piece of information in these tables [Link removed due to restriction: Oops! Your edit couldn't be submitted because: We're sorry, but as a spam prevention mechanism, new users can only post a maximum of two hyperlinks. Earn more than 10 reputation to post more hyperlinks. Link is below]. Further on, the object class dictates which properties must and can be added in the record. Here, organizationalUnit must have an ou: entry and must not have neither dc: nor o: entry. The healthy init.ldif file looks like that: dn: ou=webtool,o=myOrg,c=de objectclass: organizationalUnit ou: LDAP server for my webtool dn: cn=ldapadmin,ou=webtool,o=myOrg,c=de objectclass: organizationalRole cn: ldapadmin Note: The page also states: “While many objectClasses show no MUST attributes you must (ouch) follow any hierarchy […] to determine if this is the really case.” I thought that would mean my root record would have to provide the must fields for c= and o= (c: and o:, respectively) but this isn’t the case. Link in answer is (1): http :// www (dot) zytrax (dot) com/books/ldap/ape/ "Appendix E: LDAP - Object Classes and Attributes"

    Read the article

  • Windows 7 sometimes boots in VGA mode

    - by TuxRug
    I have an Asus G50VT-x5 laptop with nVidia GeForce9800M-GS graphics. Normally, Windows boots normally, but about 20% of the time (rough estimate), it will boot with the fallback VGA driver, maxing out at 800x600 with no Aero. I've checked the system logs and there is nothing indicating an error loading the nVidia driver. It even specifies in the logs that the Nvidia Display Driver service started successfully, even though it has booted in safe graphics mode. This has been happening for a while, but it's happening a little more often now than it was before. Since the first time my system exhibited this behavior, I have updated my graphics driver a handful of times. I used System Information for Windows to check for problems there, but the only thing that stood out was the following: Core Temperature 4486449 °C (8075639 °F) Shaders Temperature 1171513530 °C (2108724330 °F) I know this reading is incorrect, because my laptop is nowhere near the surface of the sun and my desk has not burst into flames. When it's opererating normally, I get a sane reading like [Core Temperature 58 °C (136 °F)] with no Shaders Temperature listed. All I have to do to resolve the issue is reboot. I have seen no stability issues with the graphics or anything else. A long time ago, I had an issue with this computer where my framerate would suddenly drop during a 3D game from 40fps to <1fps, but after looking at the temperature readout immediately after quitting a game, I removed the bottom panel and blew the dust out of the vent and heatsink. Since then I have no drops in framerate under any situation. I have uploaded a zip containing the SIW reports for when the problem is occurring and when the computer is operating normally. I don't have a paid account so it can only be downloaded 10 times, so please only download the reports if you think you can use them. If you try to download the reports and they are no longer available, please comment and I will re-upload them. If you want to look at the files, they are on Rapidshare. EDIT It happened again, and I looked a little deeper into the System logs. When this happens, there are a lot of errors about other device drivers unable to start. All of these errors are for PnP drivers. Also, my USB keyboard and mouse take a few moments before they actually start working, although this happens sometimes the first normal boot as well. I am quite sure this is related, so I am adding the pnp tag. Also, CHKDSK will not run on boot. Even if a check is scheduled or a volume is manually set as dirty, CHKDSK will be skipped entirely, not even leaving an entry in the System logs. I tried running CHKNTFS /D, which did not work. I then manually changed my HKLM\System\CurrentControlSet\Control\Session Manager BootExecute value to the default listed on Microsoft's website. That did not work either. I ended up booting to repair mode and running CHKDSK there, which found a number of minor inconsistencies on my system drive, but none on my data drive. I have no idea if this is related. Some more information for those who don't download my SIW report file: Antivirus and Firewall are ESET Smart Security I have three different virutalization programs installed: VMware Player, Windows Virtual PC, and VirtualBox. The network adapters for these show up in the log of failed device starts. EDIT 2 I tried running sfc /scannow, which reported that it found corrupted files that could not be fixed. The CBS log is extremely cryptic. I tried booting to my install disk, launching repair mode, and doing an offline sfc from there, which produced the same result.

    Read the article

  • How to get ISA 2006 Web Proxy to work with the Single Network Adapter template

    - by tronda
    I need to test an issue with running our application behind a proxy server with different type of configurations, so I installed ISA 2006 Enterprise on a desktop computer. Since this computer only has a single network card and I want to start out easy, I chose the "Single Network Adapter" template. We have a internal NAT'ed network which is in the 10 range. I have defined the internal network on the ISA server to be 10.XXX.YY.1 - 10.XXX.YY.255 I also have the Default rule which denies all traffic, but I've added the following Rule: Policy - Protocols - From - To Accept HTTP Internal External HTTPS Local Host Internal HTTS Server Localhost Then I configured Internet Explorer on a virutal machine running XP within virtualbox with Brigded network (gets same network address range as regular computers on our network) similar to this Instead of the server name I used the IP address. When I try to access a web page, this doesn't go through and I get the following log messages on the proxy server: Original Client IP Client Agent Authenticated Client Service Referring Server Destination Host Name Transport HTTP Method MIME Type Object Source Source Proxy Destination Proxy Bidirectional Client Host Name Filter Information Network Interface Raw IP Header Raw Payload GMT Log Time Source Port Processing Time Bytes Sent Bytes Received Cache Information Error Information Authentication Server Log Time Client IP Destination IP Destination Port Protocol Action Rule Result Code HTTP Status Code Client Username Source Network Destination Network URL Server Name Log Record Type 10.XXX.YY.174 - TCP - - - 24.08.2010 13:25:24 1080 0 0 0 0x0 0x0 - 24.08.2010 06:25:24 10.XXX.YY.174 10.XXX.YY.175 80 HTTP Initiated Connection MyHTTPAccess 0x0 ERROR_SUCCESS Internal Local Host - PROXYTEST Firewall 10.XXX.YY.175 - TCP - - - 24.08.2010 13:25:24 2275 0 0 0 0x0 0x0 - 24.08.2010 06:25:24 10.XXX.YY.175 10.XXX.YY.175 80 HTTP Initiated Connection 0x0 ERROR_SUCCESS Local Host Local Host - PROXYTEST Firewall 10.XXX.YY.175 - TCP - - - 24.08.2010 13:25:25 2275 0 0 0 0x0 0x0 - 24.08.2010 06:25:25 10.XXX.YY.175 10.XXX.YY.175 80 HTTP Closed Connection 0x80074e20 FWX_E_GRACEFUL_SHUTDOWN Local Host Local Host - PROXYTEST Firewall 10.XXX.YY.175 - TCP - - - 24.08.2010 13:25:25 2276 0 0 0 0x0 0x0 - 24.08.2010 06:25:25 10.XXX.YY.175 10.XXX.YY.175 80 HTTP Initiated Connection 0x0 ERROR_SUCCESS Local Host Local Host - PROXYTEST Firewall 10.XXX.YY.175 - TCP - - - 24.08.2010 13:25:26 2276 0 0 0 0x0 0x0 - 24.08.2010 06:25:26 10.XXX.YY.175 10.XXX.YY.175 80 HTTP Closed Connection 0x80074e20 FWX_E_GRACEFUL_SHUTDOWN Local Host Local Host - PROXYTEST Firewall 10.XXX.YY.175 - TCP - - - 24.08.2010 13:25:26 2277 0 0 0 0x0 0x0 - 24.08.2010 06:25:26 10.XXX.YY.175 10.XXX.YY.175 80 HTTP Initiated Connection 0x0 ERROR_SUCCESS Local Host Local Host - PROXYTEST Firewall 10.XXX.YY.159 - UDP - - - 24.08.2010 13:25:26 68 0 0 0 0x0 0x0 - 24.08.2010 06:25:26 10.XXX.YY.159 255.255.255.255 67 DHCP (request) Denied Connection [Enterprise] Default rule 0xc004000d FWX_E_POLICY_RULES_DENIED Internal Local Host - PROXYTEST Firewall 10.XXX.YY.166 - UDP - - - 24.08.2010 13:25:26 68 0 0 0 0x0 0x0 - 24.08.2010 06:25:26 10.XXX.YY.166 255.255.255.255 67 DHCP (request) Denied Connection [Enterprise] Default rule 0xc004000d FWX_E_POLICY_RULES_DENIED Internal Local Host - PROXYTEST Firewall 0.0.0.0 Mozilla/4.0 (compatible; MSIE 8.0; Windows NT 5.1; Trident/4.0; .NET CLR 2.0.50727; .NET CLR 3.0.4506.2152; .NET CLR 3.5.30729) Yes Proxy 10.XXX.YY.175 TCP GET Internet - - - Req ID: 096c76ae; Compression: client=No, server=No, compress rate=0% decompress rate=0% - - - 24.08.2010 13:25:27 0 2945 2581 446 0x0 0x40 24.08.2010 06:25:27 10.XXX.YY.174 10.XXX.YY.175 80 http Failed Connection Attempt MyHTTPAccess 10061 anonymous Internal Local Host http://www.vg.no/ PROXYTEST Web Proxy Filter 10.XXX.YY.175 - TCP - - - 24.08.2010 13:25:27 2277 0 0 0 0x0 0x0 - 24.08.2010 06:25:27 10.XXX.YY.175 10.XXX.YY.175 80 HTTP Closed Connection 0x80074e20 FWX_E_GRACEFUL_SHUTDOWN Local Host Local Host - PROXYTEST Firewall

    Read the article

  • Why is syslog so much slower than file IO?

    - by ceving
    I wrote a simple test program to measure the performance of the syslog function. This are the results of my test system: (Debian 6.0.2 with Linux 2.6.32-5-amd64) Test Case Calls Payload Duration Thoughput [] [MB] [s] [MB/s] -------------------- ---------- ---------- ---------- ---------- syslog 200000 10.00 7.81 1.28 syslog %s 200000 10.00 9.94 1.01 write /dev/null 200000 10.00 0.03 343.93 printf %s 200000 10.00 0.13 76.29 The test program did 200000 system calls writing 50 Bytes of data during each call. Why is Syslog more than ten times slower than file IO? This is the program I used to perform the test: #include <fcntl.h> #include <stdio.h> #include <string.h> #include <sys/stat.h> #include <sys/time.h> #include <sys/types.h> #include <syslog.h> #include <unistd.h> const int iter = 200000; const char msg[] = "123456789 123456789 123456789 123456789 123456789"; struct timeval t0; struct timeval t1; void start () { gettimeofday (&t0, (void*)0); } void stop () { gettimeofday (&t1, (void*)0); } void report (char *action) { double dt = (double)t1.tv_sec - (double)t0.tv_sec + 1e-6 * ((double)t1.tv_usec - (double)t0.tv_usec); double mb = 1e-6 * sizeof (msg) * iter; if (action == NULL) printf ("Test Case Calls Payload Duration Thoughput \n" " [] [MB] [s] [MB/s] \n" "-------------------- ---------- ---------- ---------- ----------\n"); else { if (strlen (action) > 20) action[20] = 0; printf ("%-20s %-10d %-10.2f %-10.2f %-10.2f\n", action, iter, mb, dt, mb / dt); } } void test_syslog () { int i; openlog ("test_syslog", LOG_PID | LOG_NDELAY, LOG_LOCAL0); start (); for (i = 0; i < iter; i++) syslog (LOG_DEBUG, msg); stop (); closelog (); report ("syslog"); } void test_syslog_format () { int i; openlog ("test_syslog", LOG_PID | LOG_NDELAY, LOG_LOCAL0); start (); for (i = 0; i < iter; i++) syslog (LOG_DEBUG, "%s", msg); stop (); closelog (); report ("syslog %s"); } void test_write_devnull () { int i, fd; fd = open ("/dev/null", O_WRONLY); start (); for (i = 0; i < iter; i++) write (fd, msg, sizeof(msg)); stop (); close (fd); report ("write /dev/null"); } void test_printf () { int i; FILE *fp; fp = fopen ("/tmp/test_printf", "w"); start (); for (i = 0; i < iter; i++) fprintf (fp, "%s", msg); stop (); fclose (fp); report ("printf %s"); } int main (int argc, char **argv) { report (NULL); test_syslog (); test_syslog_format (); test_write_devnull (); test_printf (); }

    Read the article

  • Server Cabinet/Room Cooling

    - by user37226
    Hello all. I currently have two desktops and three servers in my office sitting on the floor (I know this is bad). With that many servers the ambient temperature in the room goes up quickly. I am located in Dallas, TX so during the winter, if the heat is kept low, it is not a problem, but during the summer it easily jumps the room +10 degrees. I have decided and found a free 42U server cabinet that a hosting company was throwing away to house all of these systems in. One server is in a rack mount case while the other four servers are housed in mid-tower cases. I have purchased shelves for each computer and plan to lay the towers side ways on these shelves (as replacing the cases costs a heck of a lot of money). I like the idea of housing all of these systems in the cabinet because it will save a lot of room and clean up all of the cabling currently laying all over the office floor. When putting this setup together over the next couple of weeks, I want to address issues with dust and cooling. The server cabinet has a fan on top, front plexiglass door and a rear metal door with vent wholes on the bottom. First the cooling issues. I know I am going to want to have cool air enter the bottom of the cabinet and exit the top. I do not want the room heating up though as this will make my work area hot and then make the servers warmer as the air eventually reenters the cabinet. I had an idea to fix this problem, but am unsure if it will work. I was thinking of taking flexible piping and adapting it to the back fans of the computer having the other end of the pipe at the top close to the cabinet's top mounted fan. I was then thinking of creating a duct around the top fan into the attic. Now I am very concerned that the attic will cause issues with this type of setup because during July/August time frame, the attic is easily 120 degrees F. I could also use the flexible pipe to take it to an attic exhaust vent if it would be better to vent it into the 100 degree air outside (at least there may be wind. The other option would be to buy a small portable air conditioner. This may be a possibility, but do I want to spend the extra money on power? I bet this increases the noise. Plus they are around $250 on Amazon. What would you all recommend? Depending on the solution I end up running with above, I would also like to limit the dust that gets into the cabinet. If I were to cut a whole and mount a second cabinet fan on the bottom of the rear door, could I possibly mount a standard home air filter on the other side of that whole? Thanks in advance for your recommendations. I look forward to reading your interesting ideas.

    Read the article

  • Server Cabinet/Room Cooling

    - by user37226
    Hello all. I currently have two desktops and three servers in my office sitting on the floor (I know this is bad). With that many servers the ambient temperature in the room goes up quickly. I am located in Dallas, TX so during the winter, if the heat is kept low, it is not a problem, but during the summer it easily jumps the room +10 degrees. I have decided and found a free 42U server cabinet that a hosting company was throwing away to house all of these systems in. One server is in a rack mount case while the other four servers are housed in mid-tower cases. I have purchased shelves for each computer and plan to lay the towers side ways on these shelves (as replacing the cases costs a heck of a lot of money). I like the idea of housing all of these systems in the cabinet because it will save a lot of room and clean up all of the cabling currently laying all over the office floor. When putting this setup together over the next couple of weeks, I want to address issues with dust and cooling. The server cabinet has a fan on top, front plexiglass door and a rear metal door with vent wholes on the bottom. First the cooling issues. I know I am going to want to have cool air enter the bottom of the cabinet and exit the top. I do not want the room heating up though as this will make my work area hot and then make the servers warmer as the air eventually reenters the cabinet. I had an idea to fix this problem, but am unsure if it will work. I was thinking of taking flexible piping and adapting it to the back fans of the computer having the other end of the pipe at the top close to the cabinet's top mounted fan. I was then thinking of creating a duct around the top fan into the attic. Now I am very concerned that the attic will cause issues with this type of setup because during July/August time frame, the attic is easily 120 degrees F. I could also use the flexible pipe to take it to an attic exhaust vent if it would be better to vent it into the 100 degree air outside (at least there may be wind. The other option would be to buy a small portable air conditioner. This may be a possibility, but do I want to spend the extra money on power? I bet this increases the noise. Plus they are around $250 on Amazon. What would you all recommend? Depending on the solution I end up running with above, I would also like to limit the dust that gets into the cabinet. If I were to cut a whole and mount a second cabinet fan on the bottom of the rear door, could I possibly mount a standard home air filter on the other side of that whole? Thanks in advance for your recommendations. I look forward to reading your interesting ideas.

    Read the article

  • Determining the required depth and specifications for a server cabinet

    - by Bingu Bingme
    I'm trying to understand the considerations ("why") that go into determining the specifications ("what") for a rackmount server cabinet, in order to determine what sort of rack I should purchase for my home use. Since this is for home use, I won't be following certain best practices (eg. hot/cold aisle, not even air conditioning) and may be willing to sacrifice in various areas in order to reduce cost and footprint - but please advise if there are safety concerns or other considerations to note. The most basic specs for a server cabinet are the dimensions (external width x external depth x usable height). Width: commonly 600mm or 800mm (if the use case requires extra clearance around the sides, such as if there is lots of cabling). In my case and most common cases, I'm going to stick with 600mm. Height: Select a sufficiently tall rack to fit my equipment. But how much may I stuff into it? Eg, if there is a 15U rack, can I really populate it with 15U of servers, or should I leave 1U at top and bottom for air circulation? Depth: Racks commonly have external depth of 600mm (network equipment), 800mm, 1000mm, or even longer. I'm trying to see how to fit into the 800mm depth. With reference to http://www.server-racks.com/rack-mount-depth.html, I'm hoping to have the front and rear posts mounted ~ 28.5" (72cm) apart, which would leave only 8cm for front space and rear space. How much rear space (from rear posts to back of rack) do I really need? I won't use cable management arms, so can I mount a 72cm depth server since the power, KVM, network cables won't take up much depth? My most important equipment are all < 60cm depth (4U chassis) and should comfortably fit within the 800mm cabinet. The rest of the equipment are very old 1U servers that range from 65-72cm depth. I might still want to make further use of them, or I might discard them since they are so old. Even if the 72cm servers cannot be powered on in an 800mm rack, I should be able to use them as 1U shelves. But, what server depth can I expect to be able to operate? Or am I forced to upgrade to 1000mm depth racks in order to use any servers deeper than 60cm? With reference to best practices for HP racks, some other specs and installation considerations: There aren't any minimum recommendations for clearance on the sides of the rack. It is recommended to leave 48" front clearance. The 48" front clearance is based on 32" chassis depth, 13" to extend the rack rails and mate the inner/outer rails, and 3" for movement. If I don't use such rails (eg, use shelves instead), it should be sufficient to leave front clearance of chassis depth + 3". It is recommended to leave 30" rear clearance "to provide space for servicing the rack". I'm planning to back the rack into a corner of the room, and wheel it slightly out when I need to access the rear. If the wheeling plan is ok, I still need to know how much rear clearance is required for air circulation and ventilation purposes. Castor wheels and stabilising feet. Since I'm backing the rack into a corner of the room, I'll only be able to set the stabilising feet on the front corners. Thoughts on safety? The rack that I'm considering has front glass doors with side ventilation slits and fully perforated rear doors. I'm hoping this will be a good balance between temperature and noise (only ventilation slits facing out the front, while the rear is facing the walls). Or is the sound of high-rpm fans going to escape through the front slits anyway and destroy my sanity?

    Read the article

< Previous Page | 706 707 708 709 710 711 712 713 714 715 716 717  | Next Page >