Search Results

Search found 24734 results on 990 pages for 'floating point conversion'.

Page 751/990 | < Previous Page | 747 748 749 750 751 752 753 754 755 756 757 758  | Next Page >

  • I need to preserve a tape using symantec backup exec. I'm aving trouble doing so

    - by MrVimes
    Please forgive me if this is the wrong stack exchange site. Please suggest which one I should post this to if it is. There's an automatic tape machine running in a remote location, with software (symantec backup exec 11d) Recently one of the servers being backed up had problems with its raid controller, so one of the drives has become invisible. I need to preserve the last good backup of that drive so I am trying to replace the tape with the most recent backup of that drive on it with one of the scratch tapes (blank tapes) present in the machine. I've tried the following... Associate the blank media with the media set in question (Wednesday) For the existing media (the tape with the data I want to keep) I click 'move to vault' and move it to the offline vault. I associate it with something other than 'Wednesday' (a media set called 'keep data infinitely...') I then do an inventory on that slot. The above steps I'm led to believe are supposed to put the fresh tape in the slot that had the tape I want to keep in it. But it just keeps showing up as containing the tape I want to keep after the inventory. (after refreshing the device tree) I am a complete newbie with this software. Can you tell me what I'm doing wrong, and/or tell me how to acheive my desired goal Edit: Just want to point out that I did try to get help directly from symantec with this, but having jumped through countless hoops to create an account and create a support ticket my progress was halted by requiring something called a 'tecnical contact id' at the final step with no explanation of what it is or how to get one.

    Read the article

  • computer fails to boot during/after POST for five or six boots, then works

    - by N13
    For the last few days, my computer has had issues booting. I've seen two different behaviors: The screen displays the graphics card information, then begins to list the RAM, hard drives, etc. At different points in this process (after the graphics info), the computer shuts off. After five or six attempts, it then boots normally. In roughly the same time frame, the computer freezes, and fails to boot. I think it boots successfully on the next attempt. I've also noticed that in some instances, the computer freezes on shutdown. It gets right to the point where it should shut off, but doesn't. I recently combined the best parts of two different machines into this one. I'm booting to GRUB, with Ubuntu 12.04, Linux Mint 11 and Windows Vista (unfortunately) as my OS options. It has an Enermax Modu82+ 525W power supply, and I've used an online calculator to determine that my load shouldn't exceed 400W. I even unplugged a hard drive, but that didn't help. I found the latest BIOS, patched it and checked the settings, but that didn't fix it. I'm fairly certain this issue didn't exist at first, but might have started when the power at my new apartment dropped for a second. The machine is plugged into a surge protector strip, but it's old and I've heard they lose effectiveness with age. Is a power dip as damaging as a spike? If something were damaged, why would it boot successfully after five or six attempts? It's almost like the BIOS or PSU need to be primed. The trouble with debugging is that there seems to be a "grace period" after shutdown where the issue doesn't present itself again. What should I try next?

    Read the article

  • Macports install of ack doesn't create correct executable

    - by user1664196
    I am trying to install p5-app-ack port from Mac Ports, but it seems it doesn't create a /opt/local/bin/ack binary at the end: $ sudo port search *app-ack Password: p5-app-ack @1.960.0 (perl) A grep replacement that ignores .svn/CVS/blib directories p5.8-app-ack @1.960.0 (perl) A grep replacement that ignores .svn/CVS/blib directories p5.10-app-ack @1.960.0 (perl) A grep replacement that ignores .svn/CVS/blib directories p5.12-app-ack @1.960.0 (perl) A grep replacement that ignores .svn/CVS/blib directories p5.14-app-ack @1.960.0 (perl) A grep replacement that ignores .svn/CVS/blib directories p5.16-app-ack @1.960.0 (perl) A grep replacement that ignores .svn/CVS/blib directories Found 6 ports. $ perl --version This is perl 5, version 12, subversion 4 (v5.12.4) built for darwin-thread-multi-2level Copyright 1987-2010, Larry Wall Perl may be copied only under the terms of either the Artistic License or the GNU General Public License, which may be found in the Perl 5 source kit. Complete documentation for Perl, including FAQ lists, should be found on this system using "man perl" or "perldoc perl". If you have access to the Internet, point your browser at http://www.perl.org/, the Perl Home Page. $ sudo port install p5-app-ack ---> Computing dependencies for p5-app-ack ---> Cleaning p5-app-ack ---> Updating database of binaries: 100.0% ---> Scanning binaries for linking errors: 35.0% ---> No broken files found. $ $ ls /opt/local/bin/ac* /opt/local/bin/ack-5.12 /opt/local/bin/aclocal /opt/local/bin/aclocal-1.12 /opt/local/bin/activation-client /opt/local/bin/acyclic $ which ack $ ack -bash: ack: command not found Update If I then try to install p5.12-app-ack afterwards, I get $ sudo port install p5.12-app-ack Password: ---> Computing dependencies for p5.12-app-ack ---> Cleaning p5.12-app-ack ---> Scanning binaries for linking errors: 100.0% ---> No broken files found. $

    Read the article

  • Prevent Linux from processing incoming ICMP Host unreachable packets

    - by bbc
    I have a test setup with one host on a network (10.1.0.0/16) talking via TCP to another one on another network (10.2.0.0/16) and a gateway in the middle. Sometimes, the TCP connection is lost and while scanning the trace (pcap), I looks like it's because of just one ICMP Host unreachable message sent by the gateway to 10.1.0.1 at some point. 10.1.0.1 then sends a TCP RST to 10.2.0.1. In my opinion, the gateway (pfSense) is broken or not configured correctly but anyway, for testing purposes, I'd like to block this kind of ICMP on the host (10.1.0.1) before it has an influence on my TCP connection (or does it? I'm not even sure). I've tried iptables: iptables -I INPUT -i eth0 -p icmp --icmp-type host-unreachable -j DROP but while it does a good job at preventing userpace applications like ping from receiving these ICMP messages, my TCP connection still comes to an end when the alleged "killer ICMP packet" is sent by the gateway. Am I right about how it is processed? If yes, then what can I do to achieve my goal?

    Read the article

  • WSUS performance for unneeded updates

    - by mhouston100
    We have a WSUS server serving around 300 PC's and a couple of dozen servers and a discussion came up at work as to what products to include. We have a single SQL 2005 instance on one of the servers and it has NEVER been updated. My first thought was to just tick the box for SQL 2005 and let WSUS do it's thing to upgrade to the latest service pack at least. One of the other guys here has the opinion that having updates that are relevant to only a small selection of hosts would effect the performance of WSUS as a whole, claiming that each update does a 'check' against all the hosts or something similar. My argument is that manually updating these servers is obviously not working as the admins are not paying attention to what is needed. So my question is: Do updates that only effect a sub-set of the hosts effect the overall performance of the WSUS server in relation to ALL the hosts? (disk space is not an issue at this point) Is there any performance justification for or against manually updating small amounts of products? Basically I'm needing a rebuttal against his argument and I'm unable to find any concrete documentation to prove him wrong.

    Read the article

  • Ubuntu 9.04: Ripping CDs with grip?

    - by chris
    I tried to rip a CD tonight, and couldn't figure out how to configure grip - /dev/cdrom doesn't seem to be the mount point for music CDs any more. How can I configure grip to find CDs? Update: /etc/fstab has /dev/scd0 /media/cdrom0 udf,iso9660 user,noauto,exec,utf8 0 0 But there's nothing visible in /media/cdrom0 (or /media/cdrom, which is a symlink to cdrom0) There's an icon on the desktop labeled "Audio Disk" and opening it shows the .wav files on the CD. The location is cdda://sr0/, but grip doesn't like that either. Trying to manually mount /dev/sr0, I get $ sudo mount -t auto /dev/sr0 foo/ mount: block device /dev/sr0 is write-protected, mounting read-only mount: you must specify the filesystem type Update 2: Tried to change the media handling preferences (From a file browser, Edit-Preferences, Media, CD Audio) to "Do Nothing". CD Still doesn't mount. Update 3: With an audio CD in the drive: $ ls -l /dev/ | grep cd lrwxrwxrwx 1 root root 3 2009-09-15 22:13 cdrom1 -> sr0 lrwxrwxrwx 1 root root 3 2009-09-15 22:13 cdrw1 -> sr0 drwxr-xr-x 2 root root 60 2009-09-15 22:13 pktcdvd lrwxrwxrwx 1 root root 3 2009-09-15 22:13 scd0 -> sr0 crw-rw----+ 1 root cdrom 21, 2 2009-09-15 22:13 sg2 brw-rw----+ 1 root cdrom 11, 0 2009-09-15 22:13 sr0

    Read the article

  • Dell Vostro Desktop error.

    - by goldenmean
    Faced a strange situation at work today. We have people sitting at a table on opposite sides, with power cables underneath the table. This morning when the person sitting opposite to me banged his feet on ground, it disturbed the power cable to my PC and it turned-off. So when I turned it on, it says, "No boot device found" Press F1 to setup or F5 to perform test... There was no physical impact/crash/fall of the desktop cabinet, which could have crashed/damaged the hard disk physically. EDIT: The OS is Windows 7 So I tried to recognize it in the Bios setup, but even there it could not find the SATA disk that is connected to this machine. So then I opened the cabinet, removed the power supply and plugged it back again. Tried to reboot, same error, "Boot device not found" It is not recognizing the hard disk. Any ideas about what might be wrong? Hard-disk crash, OS Crash(But it doesn't even go to the point of loading the disk after the initial Bios execution, so doubt this...) Any pointers about how I should proceed to troubleshoot/solve this error are welcome.

    Read the article

  • Remote network traffic not passing through VPN

    - by John Virgolino
    We have the following topology: LAN A LAN B LAN C 10.14.0.0/16 <-VPN-> 10.18.0.0/16 --- SONICWALL <-VPN-> M0N0WALL --- 10.32.0.0/16 Traffic between LAN A and LAN B works perfectly. Traffic between LAN C and LAN B works perfectly. Traffic between LAN A and LAN C, not so much. LAN A's gateway has a route to LAN C that points to the Sonicwall. The Sonicwall has a route to LAN A pointing to the VPN gateway connecting LAN B to LAN A. Tracing packets on the Sonicwall shows the LAN C destined traffic to arrive on the Sonicwall, but it does not forward the traffic, it dies there. Traffic from LAN B gets forwarded. Tracing packets on the Sonicwall while sending traffic from LAN C destined for LAN A shows nothing. This tells me that the M0N0WALL is not forwarding traffic for the 10.14.0.0 network and the Sonicwall is not forwarding from 10.14.0.0. The SA on the Sonicwall terminates on the WAN ZONE and is defined to use an address group that incorporates both the 10.14.0.0 and 10.18.0.0 networks. The M0N0WALL is configured for the 10.18.0.0 network and I have tried with both a static route to 10.14.0.0 and without on the M0N0WALL. I tried manually adding the 10.14.0.0 network to the SA on the M0N0WALL, but that really aggravated it and the SA never came up, so I reverted. I have checked all the firewall rules to make sure nothing is blocked. All of the Sonicwall auto-added rules look right. Specs: Sonicwall TZ200, Enhanced OS M0N0WALL v1.32 I'm at a loss at this point. Any help would be appreciated.

    Read the article

  • 2008 SR2 Server Starts Then Fails to Initialize DNS

    - by ThaKidd
    Got a weird situation going on. Background: Just transferred Active Directory from a 2003 Server to 2008 SR2. Removed the 2003 server from AD but I have not upgraded Active Directory to 08 only yet. After the transition a problem started. Whenever I reboot the server and I log in, the DNS server is "stopping". After a few minutes it finishes and I can restart start it at that point. Once it is restarted, all services come up. Now I did try to install HyperV (this is a dev server btw). Once the reboot for HyperV, everything was screwed as in I could not ping anything. Uninstalled and had the DNS server issue. Screwed with IPv6 settings (which I am not using) and problem was resolved for a bit. Also installed an Intel Pro1000 card and had a bit of success with DNS; then it failed. Weird thing is, outside of an error in syslog stating that the DNS server failed to start, there is no specific error that is generated in either System or DNS Server logs. Ideas are much appreciated! Thanks in advance.

    Read the article

  • Why is only one Excel spreadsheet crippled, but others are fine?

    - by Dallas
    I have an inherited spreadsheet that I really don't want to rebuild at the moment. It's a simple small workbook that is small (< 200 rows that don't even reach to AA) and does nothing more than calculate some totals within the same worksheets. No macros, no external data sources, nothing beyond basic formatting of dates, numbers and strings. I see importing data from CSV/text has created many many workbook connections over time, but even if I delete them all (there were hundreds) it makes no difference in performance. Even clicking to simply change focus from cell to cell takes 10+ seconds, adorned by the spinning cursor and (Not Responding) appending to the title bar and the application locking up. The program seems to "recover" every time, but efficiency of editing this file is obviously seriously handicapped. All other files seem fine in Excel, and other programs have no apparent performance issues. I see Excel is chewing up CPU but I'm not sure how to narrow down what process or service is "clashing" with Excel. I tried the same file on other computers and performance is fine. If I turn off all start-up services and run only Excel, performance is restored... until I start using other programs and then it bogs down again. At this point, I would entertain almost any idea, theory or suggestion that helps pinpoint, solve or work around the issue.

    Read the article

  • Coloring of collapsed threads in mutt

    - by Rich
    I'm trying to figure out the syntax of colouring collapsed threads in the mutt index. The documentation for mutt patterns doesn't seem to include a description of how this works, and so far I've been completely unable to figure it out by trial and error. What I'd like is for collapsed threads that contain any unread (new) messages to be always coloured green. If collapsed threads with no unread messages contain any flagged messages, then I'd like them to be red. So far, every set of patterns I've tried results in threads that contain both flagged and unread messages being coloured red (I want them green). These work: color index green default "~N" # unread messages color index green default "~N~F" # unread flagged messages color index red default "~F" # flagged messages color index green default "~v~(~N)" # collapsed thread with unread But these don't: color index green default "~v~(~N~F)" # attempt to keep threads with unread green color index red default "~v~(~F)" # colours collapsed threads with flagged and unread red color index red default "~v~(!~N~F)" # ditto color index red default "~v~(^!~N~F)" # ditto color index red default "~v~(~F)~(!~N)" # ditto color index red default "~v~(~F)~v~(!~N)" # ditto I've also tried switching the order of the "~v~(~F)" and "~v~(~N)" commands in the file, but the "flagged" rule always seems to take precedence over the "new" rule. Ideally I'd like to understand how the syntax for colouring collapsed threads works, but at this point I'd happily settle for a set of rules that achieves the colourscheme described above.

    Read the article

  • Manual Http error response code in non-existent folder via routing

    - by Slytherin
    Apache server running on ubuntu-like linux I am getting unexpected behaviour when i try to manually send error response. If my .htaccess is responsible for the error response , then appropriate error document is loaded and displayed , with according response code in browser console. However , if my router is origin of the response code , then i get blank screen , but correct response code. .htaccess looks like this RewriteEngine On # RewriteBase / RewriteCond %{REQUEST_FILENAME} !-f RewriteCond %{REQUEST_FILENAME} !-d RewriteRule !\.(css|js|icon|zip|rar|png|jpg|gif|pdf)$ index.php [L] ErrorDocument 404 /err/404.html ErrorDocument 403 /err/403.html ErrorDocument 500 /err/500.html part of my router that sends the response is the following header("HTTP/1.1 403 Forbidden"); trying this format didnt help either header("HTTP/1.1 403 Forbidden", TRUE, 403); I also tried HTTP/1.0. Furthermore i was thinking that maybe relative path to error page might be an issue , but discarded this idea after attempting to access a document that is forbidden via .htaccess EDIT I should also point out , this scenario happens when URL for not-existing article is requested. Is it possible that Server is looking for a .htaccess file in a folder based on URL ? Eg: domain/blog/non-existent , is server looking for blog folder ? I am specifically asking this because there is no blog folder

    Read the article

  • Delayed internet access

    - by Joel Coel
    When I (and presumably my users) first start up or log in to my computer I can't get internet access until several minutes after logging in. Internet pages like serverfault.com will time out. During this time I can access internal web servers. Sometimes pinging the gateway seems to fix the problem. I'm using Windows 7 on this machine with wifi, and the problem seems limited to the wifi network, which is on a separate vlan. The wired network does not share the problem, but I know it's not the wifi connection itself because the internal sites work. The wifi access point is attached to a 3Com 4200 switch, with the port set for vlan 2 untagged, vlan 1 tagged. The 4200 has a fiber connection to a 3Com 4900SX fiber switch that acts almost as a router here. The fiber connection is vlan 1 untagged vlan 2 tagged at both ends. The gateway is then attached to a different 4200 (vlan 1 untagged, vlan 2 tagged) that has a similar fiber connection to the 4900SX. vlan 2 has 192.168.8.0/22 IPs, vlan 1 has 10.1.0.0/16 IPs. The 4900SX has an interface for both vlans (10.1.1.1/192.168.8.1), as does the gateway (10.1.1.5/192.168.8.5). There is one dchp server for both vlans on the same switch as the gateway. It chooses a dhcp scope based on the interface used by the 4900sx to forward the dhcp request. There is also a network access list on the 4900sx set to deny all vlan2 traffic to any 10.1.x.x host, with exceptions made for a few servers, including dhcp, 4900sx, and the gateway. I think that about covers it. Any ideas on why internet access would be delayed like this?

    Read the article

  • How to migrate Outlook Express mail rules?

    - by ronwest
    I have a home computer that only had a 15Gb C: drive, and ran out of space with all the Microsoft Updates, etc, that keep coming down. So I fitted a 160Gb drive as a C: drive and altered the drive jumpers to make the old C: drive into a slave D: drive, to save migrating documents, etc. I've installed a clean copy of Windows XP SP3 and reassigned the new Outlook Express' mailstore path to point to the old mailstore folder that now has a D: drive letter - and it all works OK. However, my extensive list of mail rules have not been transferred to the new OE and I have not been able to identify how they are stored. To find it I added a new rule to the new OE, exited OE, then searched on the whole computer (including hidden/system files) for files altered around the time I added the rule. I hoped I could just overwrite a new empty file with an old one. But the only files that seem to be changed are Windows system-level files and some bits and pieces in the Windows\PreFetch sub-folder. None of them can be opened as XP has them locked, and none of them have names that are anything to do with email or rules. Does anyone know of any way of migrating OE rules, or do I have to re-enter them by hand? Thanks!

    Read the article

  • What differences are there between "home" switches and "professional" switches?

    - by pjreddie
    Our radio station uses a PtP wireless system to stream our radio and TV signals from our studio up a hill to our transmitter. We have been having problems with warbly sound and drop outs that come from some point in this system. An engineer that occasionally visits the station thinks it could be the switches we use on each side of the PtP wireless system to connect the PtP devices to the encoders and decoders and wants us to get two of these switches: http://www.amazon.com/Netgear-JGS516-ProSafe-16-Port-Ethernet/dp/B0002CWPOK/ref=dp_return_1 The encoder/decoder setup only streams 8Mbps total so it seems like the switches we have should not be stressed out, unless they are causing sufficient latency to degrade the performance of the encoder/decoder. At each end of the connection we only have 4 connections, is there any reason we couldn't get a cheaper, "home" quality switch like this: http://www.amazon.com/D-Link-DGS-1005G-5-Port-Gigabit-Desktop/dp/tech-data/B003X7TRWE/ref=de_a_smtd Is there a significant difference that we would notice in terms of latency between these two switches? How much does the quality of the switch actually matter in this scenario? Any help is appreciated, feel free to ask questions if anything needs clarification. Thanks

    Read the article

  • Getting old bluetooth headset out of standby on Windows 7

    - by luagh45
    I think this is the problem, and if not, I'm open to suggestions. I have an old Jabra BT200 that I used to use on my phone. When a phone call was coming in it would beep using its own noises (meaning the phone never rang inside the headset) and then I could push the 'answer/hang up' button and sound and mic would start working. I have now paired it with Windows 7, and it looks good. Under the playback menu I have 'Bluetooth Hands free Audio / Jabra BT200 (Mono Audio) / Ready', and under the recording menu I have 'Bluetooth Audio Input Device / Jabra BT200 (Mono Audio) / Ready'. However when I try to test the speakers Windows sends a sound, but I never hear it, and when I talk in the mic, Windows never hears me. If I right click either the Bluetooth mic or speakers there's an option to 'Connect', but it's grayed out and I cannot click it. As the final piece of knowledge I have, my headset blinks once every 3 seconds when it's in standby and I can't get that to change. If everything was working it should blink once every second at which point I think all of my problems would be fixed. Hence my issue: I can't seem to get my headset out of standby. On my headset I've tried sending it test noises and then pressing the 'Answer' button, but still nothing. The headset beeps when I press it, so it works, it just doesn't ever come out of standby. Is there maybe some way to trick my headset into thinking it's getting a phone call from my computer?

    Read the article

  • IIS 7.0 rewrite url problem

    - by Jouni Pekkola
    Hello, How i can set redirect url for virtual directory in iis 7.0.I have installed lates url rewrite module 2. ? I could explain my problem with exsample. I have website on my iis 7.0 server: www.mysite.com I desided to create virtual directory sales under my site which is pointing to website root directory.Now I need create redirect url for the vdir. The vdir is pointing same virtual root directory as my site root is The big idea is that i can write on browser www.mysite/sales and i will automaticly redirect to url www.mysite.com?productid=200. I tried to make redirect with rewite url for vdir(not website), but I always get this error message : cannot add duplicate colletion entry of type 'rule' with unique key key attribute 'name' set to "test".This happens when i am pointing for virtual vdir and try to add rule. I can add rules to website level,but rules doesn work. I mean url www.mysite/sales gives me follwing error. I know that key is unique I checked it from web.config. This kind of feature was really easy use in IIS 6.0, just point vdir with your mouse and set properties--a redirect to url. Please some one explain what is right way to do it in IIS 7.0

    Read the article

  • Linux iptables / conntrack performance issue

    - by tim
    I have a test-setup in the lab with 4 machines: 2 old P4 machines (t1, t2) 1 Xeon 5420 DP 2.5 GHz 8 GB RAM (t3) Intel e1000 1 Xeon 5420 DP 2.5 GHz 8 GB RAM (t4) Intel e1000 to test linux firewall performance since we got bitten by a number of syn-flood attacks in the last months. All machines run Ubuntu 12.04 64bit. t1, t2, t3 are interconnected through an 1GB/s switch, t4 is connected to t3 via an extra interface. So t3 simulates the firewall, t4 is the target, t1,t2 play the attackers generating a packetstorm thorugh (192.168.4.199 is t4): hping3 -I eth1 --rand-source --syn --flood 192.168.4.199 -p 80 t4 drops all incoming packets to avoid confusion with gateways, performance issues of t4 etc. I watch the packet stats in iptraf. I have configured the firewall (t3) as follows: stock 3.2.0-31-generic #50-Ubuntu SMP kernel rhash_entries=33554432 as kernel parameter sysctl as follows: net.ipv4.ip_forward = 1 net.ipv4.route.gc_elasticity = 2 net.ipv4.route.gc_timeout = 1 net.ipv4.route.gc_interval = 5 net.ipv4.route.gc_min_interval_ms = 500 net.ipv4.route.gc_thresh = 2000000 net.ipv4.route.max_size = 20000000 (I have tweaked a lot to keep t3 running when t1+t2 are sending as many packets as possible). The result of this efforts are somewhat odd: t1+t2 manage to send each about 200k packets/s. t4 in the best case sees aroung 200k in total so half of the packets are lost. t3 is nearly unusable on console though packets are flowing through it (high numbers of soft-irqs) the route cache garbage collector is no way near to being predictable and in the default setting overwhelmed by very few packets/s (<50k packets/s) activating stateful iptables rules makes the packet rate arriving on t4 drop to around 100k packets/s, efectively losing more than 75% of the packets And this - here is my main concern - with two old P4 machines sending as many packets as they can - which means nearly everyone on the net should be capable of this. So here goes my question: Did I overlook some importand point in the config or in my test setup? Are there any alternatives for building firewall system especially on smp systems?

    Read the article

  • Write once, read many (WORM) using Linux file system

    - by phil_ayres
    I have a requirement to write files to a Linux file system that can not be subsequently overwritten, appended to, updated in any way, or deleted. Not by a sudo-er, root, or anybody. I am attempting to meet the requirements of the financial services regulations for recordkeeping, FINRA 17A-4, which basically requires that electronic documents are written to WORM (write once, read many) devices. I would very much like to avoid having to use DVDs or expensive EMC Centera devices. Is there a Linux file system, or can SELinux support the requirement for files to be made complete immutable immediately (or at least soon) after write? Or is anybody aware of a way I could enforce this on an existing file system using Linux permissions, etc? I understand that I can set readonly permissions, and the immutable attribute. But of course I expect that a root user would be able to unset those. I considered storing data to small volumes that are unmounted and then remounted read-only, but then I think that root could still unmount and remount as writable again. I'm looking for any smart ideas, and worst case scenario I'm willing to do a little coding to 'enhance' an existing file system to provide this. Assuming there is a file system that is a good starting point. And put in place a carefully configured Linux server to act as this type of network storage device, doing nothing else. After all of that, encryption on the files would be useful too!

    Read the article

  • Looking for advice on using dd to backup a dual boot laptop.

    - by AvatarOfChronos
    My questions boils down to this. If I do "dd if=/dev/sda of=usbdrive" can anybody confirm that this will get everything including mbr/partition information/all four partitions and create a drive that I can swap with the failing internal drive without losing anything? If this is done while the computer is running will it still copy everything? At this point I'm afraid to shutdown the computer for fear of it never starting again. Secondly, how tolerant is dd of failing drives? Has anybody used it to recover a half dead drive before that can share any potential pitfalls? Did it get the data ok or is this going to be a hope for the best kind of situation? And lastly, If the usbdrive is larger than the failing internal drive I'll still be able to expand the partitions later so I'm not losing space? this last part seems silly to ask but with my current streak of bad luck I'll end up overwriting some magic bit and forever turning a 640gb hdd into a 500gb hdd. Also if anybody has a better solution to create a complete clone that gets everything I'm all for hearing about it. PostScript: I had been making periodic backups however when whatever miasma that killed the laptop struck it also got the NAS :( Post PostScript: both devices were on a UPS system.

    Read the article

  • Adventures in Drupal multisite config with mod_rewrite and clean urls

    - by moexu
    The university where I work is planning to offer Drupal hosting to staff/faculty who want a Drupal site. We've set up Drupal multisite with clean urls and it's mostly working except for some weird redirects. If you have two sites where one is a substring of the other then you'll randomly be redirected to the other site. I tracked the problem to how mod_rewrite does path matching, so with a config file like this: RewriteCond %{REQUEST_URI} ^/drupal RewriteCond %{REQUEST_FILENAME} !-f RewriteCond %{REQUEST_FILENAME} !-d RewriteRule ^(.*)$ /drupal/index.php?q=$1 [last,qsappend] RewriteCond %{REQUEST_URI} ^/drupaltest RewriteCond %{REQUEST_FILENAME} !-f RewriteCond %{REQUEST_FILENAME} !-d RewriteRule ^(.*)$ /drupaltest/index.php?q=$1 [last,qsappend] /drupaltest will match the /drupal line and all of the links on the /drupaltest page will be rewritten to point to /drupal. If you put the end of string character ($) at the end of each rewrite condition then it will always match on the correct site and the links will always be rewritten correctly. That breaks down as soon as a user logs in though because the query string is appended to the url so just the base url will no longer match. You can also fix the problem by ordering the sites in the config file so that the smallest substring will always be last. I suggested storing all of the sites in a table and then querying, sorting, and rewriting the config file every time a Drupal site is requested so that we could guarantee the order. The system administrator thought that was kludgy and didn't address the root problem. Disabling clean urls should also fix the problem but the users really want them so I'd prefer to keep them if possible. I think we could also fix it by using an .htaccess file in each site to handle the clean url rewriting but that also seems suboptimal since it will generate a higher load on the server and the server is intended to host the majority of the university's external facing web content. Is there some magic I can do with mod_rewrite to get it to work? Would another solution be better? Am I doing something the wrong way to begin with?

    Read the article

  • Computer does not boot, often

    - by tam
    I've ran into a issue with my computer that it does no longer reach POST, but simply powers on for a fraction of a second and powers off. But this is not always, some times it boots just normally and it works as it should, no issues with not enough power or anything. But as soon as I turn it of, I can not turn it back on, but then again at some random point it just powers up again, and resumes normal operation. If I disconnect the 8pin ATX connector from the motherboard, it powers up, fans and disks spinning normally until I power it off again. So this problem only happens when ATX is connected, which seems odd, I normally always saw this kind of an error if ATX was not connected, but here it's the exact opposite. It also does not emit any sound on the buzzer, except the normal beep, when it powers up normally. I have already tried: Remove graphics card Remove one and/or all RAM sticks Disconnect everything non-essential, even hard drives Clear CMOS I have not yet tried to remove all components and tried to boot everything outside of the case, because I did not have the time to disassemble and bleed the water loop. However, I can confirm that nothing is stuck underneath the motherboard, not is any of those brass raisers touching the board where it should not. Specs: Gigabyte GA-970A-UD3 AMD FX6300 ATI HD7850 I think this should be enough for this issue.

    Read the article

  • Nginx: Loopback connection via PHP's getimage size crashes server (Magento's CMS)

    - by Alex
    We were able to trace down a problem that is crashing our NGINX server running Magento until the following point: Background info: Magento Backend has a CMS function with a WYSIWYG editor. This editor loads some pictures via a controller in magento (cms/directive). When we set the NGINX error_log level to info, we get the following lines (line break inserted for better readability): 2012/10/22 18:05:40 [info] 14105#0: *1 client closed prematurely connection, so upstream connection is closed too while sending request to upstream, client: XXXXXXXXX, server: test.local, request: "GET index.php/admin/cms_wysiwyg/directive/___directive/BASEENCODEDIMAGEURL,,/ HTTP/1.1", upstream: "fastcgi://127.0.0.1:9024", host: "test.local" When checking the code in the debugger, the following call does never return (in ´Varien_Image_Adapter_Abstract::getMimeType()` # $this->_fileName is http://test.local/skin/adminhtml/base/default/images/demo-image-not-existing.gif` # $_SERVER['REQUEST_URI'] = http://test.local/admin/cms_wysiwyg/directive/___directive/BASEENCODEDIMAGEURL list($this->_imageSrcWidth, $this->_imageSrcHeight, $this->_fileType, ) = getimagesize($this->_fileName); The filename requests is an URL to the same server which is requesting the script a link to a static .gif that is not existing. Sample URL: http://test.local/skin/adminhtml/base/default/images/demo-image-not-existing.gif When the above line executed, any subsequent request to the NGNIX server does not respond any more. After waiting for around 10 minutes, the NGINX server starts answering requests again. I tried to reproduce the error with a simple test script that only calls getimagesize() with the given URL - but this not crash. It simple leads to an exception saying that the URL could not be loaded (which is fine as the URL is wrong)

    Read the article

  • How to detect/list rogue computers connected to a WIFI network without access to the Wifi Router interface? [migrated]

    - by JJarava
    This is what I believe to be an interesting challenge :) A relative (that leaves a bit too far to go there in person) is complaining that their WIFI/Internet network performance has gone down abysmally lately. She'd like to know if some of the neighbors are using her wifi network to access the internet but she's not too technically savvy. I know that the best way to prevent issues would be to change the Router password, but it's a bit of a PITA having to re-configure all wifi devices... and if the uninvited guest broke the password once, they can do it again... Her wifi router/internet connection is provided by the telco, and remotely managed so she can log-on to their telco account's page and remotely change the router's Wifi password, but doesn't have access to the router status page/config/etc unless she opts out of the telco's remote support and mainteinance service... So, how could she check if there are guests in the wifi with this restrictions and in the most "point and click way"? In this case I'd probably use nmap to look for other devices in the network, but I'm not sure if that's the easiest way to do it. I'm not a wifi expert, so I don't know if there are any wifi-scanning utils that can tell us who's talking to the router... Lastly, she's a Windows user as I guess that'll influence the choice of tools available Any suggestions more than welcome Regards!

    Read the article

  • Multiple Routers, Failover, DHCP and multiple gateways. NOT WAN-failover

    - by u_b
    I've had a look around google and this forum but could not find an answer to my question. So probably one of you can help me a little. My intended setup is: Router R1: wan connection to isp. connected backup server. provides some wireless SSID. other connected devices like printer, laptop, etc. both wired and wireless. Router R2: no wan connection to isp but connected to R2. connects mp3-streamer and music server. also serves as a wireless access point with same SSID. other than described connections only wireless connections. I would like to be able to control music even if R1 is off, e.g. with no internet connection. On the other hand I would like to access internet also in the case that R2 is off, i.e. no music access. Last but not least I would like to stream internet radio, i.e., R1 and R2 are on, and music is streamed from internet to R1 to R2 to streamer. I would like to realize all this using DHCP (also using static assignments) so i do not have to configure statically on android, laptop, etc. So my questions are: Can I make DHCP provide a list of two default gateways R1,R2? In order to make clients fallback to other gateway if currently assigned gateway is turned off? Thanks in advance, u_b

    Read the article

< Previous Page | 747 748 749 750 751 752 753 754 755 756 757 758  | Next Page >