Search Results

Search found 7845 results on 314 pages for 'connected'.

Page 76/314 | < Previous Page | 72 73 74 75 76 77 78 79 80 81 82 83  | Next Page >

  • Server 2008 RAID 5 Write Speeds

    - by Solipsism
    I recently configured a RAID 5 partition in Server 2008 with 4 RAID 5 disks. These disks are connected through a SATA expansion card that uses PCIe. This morning, I checked and they had finally finished synchronizing, and so I tried to do some speed tests. Copying off the disks started pretty much fine - speeds began at 125MB/s, then trailed down to about 70MB/s, which I found odd but not worrying. Writing TO the disks however is a completely different story. I attempted to copy some of my VM host ISOs onto the disks (~2-4 GB apiece) and this resulted in speeds of approximately 10MB/s. I tried copying both from a local disk (connected directly to the motherboard) and from another server ththe gigabit network and results were the same. I checked the performance monitor while transferring the files and the only thing that stuck out was that my memory hard faults shot up to 6,000 per minute (spiking around 200/s) by explorer.exe. The system is running 2GB of DDR667 ECC RAM and a quad-core 2.3GHz opteron. Is there anything I can do to fix this performance issue (buy more RAM? move the drives to a faster box?, etc) or am I just screwed so long as I stick to windows.

    Read the article

  • how to get ip address of a PPP(Point-to-Point Protocol) network interface?

    - by Xsmael
    I have a Linux machine with two network interfaces, and I'd like to get the IP address of the PPP interface w1g1 but it doesn't show up in ifconfig. There is a public IP on the PPP interface, but there is no internet connection, I'm trying to troubleshoot but I need to get the IP address of the interface and I can't. ifconfig : eth0 Link encap:Ethernet HWaddr 00:30:48:8D:F0:2C inet addr:192.168.2.254 Bcast:192.168.2.255 Mask:255.255.255.0 inet6 addr: fe80::230:48ff:fe8d:f02c/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:9970 errors:0 dropped:567 overruns:0 frame:0 TX packets:4338 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:100 RX bytes:1441024 (1.3 MiB) TX bytes:915814 (894.3 KiB) lo Link encap:Local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 inet6 addr: ::1/128 Scope:Host UP LOOPBACK RUNNING MTU:16436 Metric:1 RX packets:675 errors:0 dropped:0 overruns:0 frame:0 TX packets:675 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:50659 (49.4 KiB) TX bytes:50659 (49.4 KiB) w1g1 Link encap:Point-to-Point Protocol UP POINTOPOINT RUNNING NOARP MTU:240 Metric:1 RX packets:748994 errors:0 dropped:0 overruns:0 frame:0 TX packets:748992 errors:0 dropped:0 overruns:0 carrier:3 collisions:0 txqueuelen:100 RX bytes:179758560 (171.4 MiB) TX bytes:179758080 (171.4 MiB) Interrupt:177 Memory:f881c400-f881e3ff w1g1 is connected to a modem by an RJ45<-Serial cable and the modem is connected to the phone line. The modem is a NOKIA DNT2Mi you can see it here Routing table : 192.168.2.0/24 dev eth0 proto kernel scope link src 192.168.2.254 169.254.0.0/16 dev eth0 scope link default via 192.168.2.180 dev eth0

    Read the article

  • CD Drive not discovered

    - by user1009073
    I have a self built computer. it uses a P6T Deluxe motherboard, which has both SATA and IDE ports. This was built several years ago, and had an IDE CD/DVD drive. This drive started going bad (would not burn CDs correctly), so I decided to replace it. I had difficultly finding an IDE DVD drive, so I bought a SATA DVD drive. I opened the comnputer, took out the old DVD drive. I left the IDE cable in place, connected to the motherboard, but it is not connected to any drives. I hooked up the new DVD drive, both power and with a SATA data cable (SATA port 3 if I recall). (Sony Optiarc 24x , Newegg URL: http://www.newegg.com/Product/Product.aspx?Item=N82E16827118067 ) When I power on my computer, the drive does NOT show up in Explorer. I can hit the DVD eject button, and the drive will open up, so I know it at least is getting power. I thought, maybe something in the BIOS. When I go to BIOS, boot devices, it shows (1) floppy, (2) my hard drive (3) ATAPI CD Drive. The only other possible BIOS option I could find was uder 'Storage Configuration'. Configure Storage as: My setting is RAID, since I am using two drives in a RAID configuration. Other options were IDE and ACHI. Other than trying to find an IDE DVD drive, is there anything else I can try? The drive does not show up at all in Windows Explorer. I did put in a CD thinking that might help, but nothing happened. Thanks, GS

    Read the article

  • Same native and tagged vlan possible on Redhat?

    - by Chris Phillips
    Hi guys and gals, I'm looking at implementing a systems using a number of tagged and a native vlan connected to a server over a a/p bonded interface. The untagged vlan is for physical machine access, the tagged vlans are connected to bridges and then to QEMU VM's inside the machine. Hopefully this plan is fine, but I'm trying to implement a crippled version of this in a dev environment due to a lack of underlying network config in this location where I just have the same single vlan delivered to the machine on a tag AND plain. I'm nto clear if this is going to work (and that I should just be confident that it will work using different vlans) as I'm seeing odd things like a vm is arping out over the vlan out to the core switch, but the arp reply is coming back on the untagged interface. Now an ARP reply is unicast right? So it's a deliberate thing to send the ARP response on the untagged interface, and not a case that a broadcast response isn't being passed on the tagged side... i.e. there's some underlying logic pushing it that way. Something about the MACs somehow? This is on a CentOS 5.5 machine, vlan's from vconfig. (I've seen reference to the Linux mac-vlan project work, but that's not available here by default.) so 1) Should having the SAME vlan tagged and untagged work? 2) Will different tagged vlans to the untagged interface work nice and easily?

    Read the article

  • Creating a Logical network diagram

    - by user273284
    Im a student and I have been assigned the task of creating a logical network diagram for the following scenario There are 2 buildings, the first is the head office and the second is the branch. The data centre is in the head office, it contains domain controller, mail server, file server and a web server. it provides wired and wireless access to the staff. the branch building is new and it does not have a network. The two buildings must be connected using a VPN connection. The branch building will not have any servers but just network devices that will provide the connectivity, the users in the branch building will be connected to the head office over the VPN. I had created a diagram based on this scenario, but my teacher rejected it saying that it does not follow Cisco hierarchical Model and the servers were not placed correctly in the diagram. I just wanted some help in this matter so that I Can create my network diagram correctly. If anyone could upload a picture of how the logical diagram should be for this scenario will be helpful, any other resources would also be great.

    Read the article

  • iptables rule on INPUT between 2 ethernet cards on the same host

    - by user1495181
    I have 2 eth cards on the same host. Both connected directly with LAN cable. I set eth0 with ip - 192.168.1.2 I set eth1 with ip - 192.168.1.1 I set this rule: iptables -A INPUT -p tcp -j NFQUEUE --queue-num 0 There are no other rules. (I ran iptables -X,-F) I send TCP syn packet ( with c++ program by using raw socket) from 192.168.1.2 to 192.168.1.1 In wireshark i see that the packet received on eth0, but the iptables rule (above) dosnt apply for this packet. when i sent the packet to remote host and apply this rule on the remote host than it work correct. So, i guess that this is due to the fact that both eth cards exists the same host. . I need to create iptables INPUT rule for local eth card (dest and src on the same machine ). I need it for simplify test. Did i guess the problem correct? is there a way to bypass this? Ps - connected them via switch didn't help. the rule wasn't applied. Run on Ubuntu. TCDUMP show the packet: 10:48:42.365002 IP 192.168.1.2.38550 > 192.168.1.1.34298: Flags [S], seq 0, win 5840, length 0 but logging of iptables like this, has nothing: iptables -A INPUT -p tcp -j LOG --log-prefix '*****************' iptables -A OUTPUT -p tcp -j LOG --log-prefix '#################'

    Read the article

  • What is the solution to enable Dymo Turbo 400 Label Printer to work on Win 7 / 64-bit?

    - by mdpc
    It's Christmas time and time for printing labels for all those Christmas cards. I've upgraded to Windows 7 64-bit from XP. I've been unsuccessfully attempting to get the connected Dymo 400 Turbo label USB printer to work again. The latest manufacturer drivers have been successfully loaded and installed. The drivers are supposed to work on Windows 7/64-bit. The Win 7 system(s) in question are patched and up-to-date on that score. The Windows Update site responds with a driver when the USB cable is connected to this printer. The printer queue seems to be established correctly. What happens is that I submit a job to the printer (either using the DYMO s/w or not), it delays for a period of time, and then I get the message 'printing error'. Can't seem to locate the appropriate error in the new and improved event log. Several combinations of rebooting, re-installation and power cycling components fail to make the printer work. Sometimes during some type of reset it spits out the last thing to be submitted, but that seems intermittent. I have tried different USB cables and different USB (2.X) ports as well. I have run the Windows 7 troubleshooter it tries to fix the problem but alas it doesn't. Interestingly, trying the USB printer (and its associated manufacturer drivers and s/w) on another Windows 7 64-bit system has the identical failures noticed on the original system. I did not find anything on the manufacturers' site concerning this problem. The printer has no hardware problems or issues.

    Read the article

  • PHP-FPM processes holding onto MongoDB connection states

    - by Brendan
    For the relevant part of our server stack, we're running: NGINX 1.2.3 PHP-FPM 5.3.10 with PECL mongo 1.2.12 MongoDB 2.0.7 CentOS 6.2 We're getting some strange, but predictable behavior when the MongoDB server goes away (crashes, gets killed, etc). Even with a try/catch block around the connection code, i.e: try { $mdb = new Mongo('mongodb://localhost:27017'); } catch (MongoConnectionException $e) { die( $e->getMessage() ); } $db = $mdb->selectDB('collection_name'); Depending on which PHP-FPM workers have connected to mongo already, the connection state is cached, causing further exceptions to go unhandled, because the $mdb connection handler can't be used. The troubling thing is that the try does not consistently fail for a considerable amount of time, up to 15 minutes later, when -- I assume -- the php-fpm processes die/respawn. Essentially, the behavior is that when you hit a worker that hasn't connected to mongo yet, you get the die message above, and when you connect to a worker that has, you get an unhandled exception from $mdb->selectDB('collection_name'); because catch does not run. When PHP is a single process, i.e. via Apache with mod_php, this behavior does not occur. Just for posterity, going back to Apache/mod_php is not an option for us at this time. Is there a way to fix this behavior? I don't want the connection state to be inconsistent between different php-fpm processes.

    Read the article

  • Siege - running a stress test benchmark

    - by morgoth84
    I need to do a benchmark test of a HTTPS server using Siege, to see how it behaves under massive load. I'm initiating tests from another machine which is quite powerful and it is connected to the same physical switch the server is connected on. But when I initiate a test, I can't get it to make more than 170 requests per second. With this load the server's CPU usage is at 15-20% and the average response time for a request is approx. 0.03 seconds. Load of the client machine is approx. at 10%. So, I gradually increase the number of users in Siege (the number of worker threads) and request rate linearly increases up to 170 reqs/sec, but it never gets over it. No matter how many more worker threads I start, the load on the server is never more than 20% (and the client's load also doesn't increase any more). How can I overcome this? I've googled a bit and found out that after a request is completed, a socket associated with one ephermal port remains in WAIT_TIME state for some time during which it can't be reused. I tried to overcome this by doing these things: sysctl -w net.ipv4.ip_local_port_range="1024 65535" echo 1 > /proc/sys/net/ipv4/tcp_tw_recycle Oh, and the client machine is a Linux (RedHat, I think, but I'm not sure). Any help would be appreciated.

    Read the article

  • Problem with setting up RAID 5 on FreeNAS

    - by Benjy23
    I've been running FreeNAS for a while now. Hardware is 1.8 GHz Celeron, RAM 1 GB. SATA card is Via - I am not sure about the model. It's 2 ports and I have 6 x 1.5 TB hard drives. All ran OK while running on 1.5 TB, no RAID. I'm now trying to create a RAID 5 with my 6 hard drives. Software RAID. Is it normal for it to take roughly up to 2 weeks just to build the RAID? Sorry, I'm very new to implementing RAID and googling doesn't tell much other than it takes a long time. Also the RAID building process seems to fail many times. Going to degraded. I suspect it's because 4 of my hard drives are connected to my motherboard and the other 2 are connected to my SATA card. What's your take? I'm considering 2 options now. Either get a 8 port SATA card and attach all the hard drives to it. Or get a RAID controller 8 portcard which is probably going to be more pricey. Also how do you access hardware RAID through FreeNAS? I like how FreeNAS emails you should your harddrive fails. Can this be done as well with hardware RAID?

    Read the article

  • Windows Server doesn't connect to a network share

    - by Dmitriy N. Laykom
    Windows Server doesn't connect to a network share. Network share is working. Blockquote Pinging 109.123.146.223 with 32 bytes of data: Reply from 109.123.146.223: bytes=32 time<1ms TTL=63 Reply from 109.123.146.223: bytes=32 time<1ms TTL=63 Reply from 109.123.146.223: bytes=32 time<1ms TTL=63 Ping statistics for 109.123.146.223: Packets: Sent = 3, Received = 3, Lost = 0 (0% loss), Approximate round trip times in milli-seconds: Minimum = 0ms, Maximum = 0ms, Average = 0ms net view \shareaddress Blockquote System error 53 has occurred. The network path was not found. When I connected the network share I observed this error message: Blockquote \ "Mapped disk letter" refers to a location that is unavailable. It could be on a hard drive on this computer, or on a network. Check to make sure that the disk is properly inserted, or that you are connected to the Internet or your network, and then try again. If it still cannot be located, the information might have been moved to a different location The network share was mounted via Group Policy. Perchance anyone knows how I can avoid this error? When the OS has been restored from the disk problem has been solved

    Read the article

  • Primary/secondary ethernet interfaces in Ubuntu 9.10

    - by Josh
    I have an Ubuntu 9.10 machine with three ethernet interfaces, eth0, eth1 and eth2. eth2 is connected to a private network. eth0 and eth2 are connected to two different LANs. Either one will provide access to the internet. All three networks have DHCP servers. Using Ubuntu's the default settings (And Gnome), when I boot up all the interfaces are active and my system gets three IP addresses. However any attempt to access the internet results in connection timeouts and other weirdness. I suspect that traffic is going out on one NIC (like eth0) and coming back in on another (like eth1). I'm not sure what's going on. The only way I can access the internet at the moment is to bring two of the devices down with ifdown. How can I configure eth0 as my primary interface so all trafic goes out by default on that interface, while keeping the other two active? Also, I want to make sure Avahi broadcasts properly on all three IPs so that the computers on the LAN of eth1 can still connect to myHostname.local...

    Read the article

  • VGA Cable gave me an Electric Shock when connecting a Projector to a Laptop

    - by Felipe Luarte
    Yesterday I was trying to connect a Viewsonic Projector to my Samsung RC420 laptop... I followed this steps: I Plugged the Projector to a power source, in parallel I did the same thing with the laptop. Then I turned on the laptop, but not the Projector (this one turns a bright light when is connected to a power source). I put the VGA Cable to the Projector (this one being still turned down) and then when I was getting close to the VGA port of the Laptop... BAM! A big spark appear between the port and the cable! Immediately the whole electricity of my floor went off. A part of the port in my laptop kind of... melted down. It seems to be where the spark started. The same thing happened to the part of the cable involved. Now I'm using the laptop, and it seems that there is no problem in it, I haven't connect anything to the VGA port yet. And the projector is still working to, well... it turns on, and I haven't connect anything yet too. The projector was connected to the power source by a homemade electric extension.

    Read the article

  • Command or tool to display list of connections to a Windows file share

    - by BizTalkMama
    Is there a Windows command or tool that can tell me what users or computers are connected to a Windows fileshare? Here's why I'm looking for this: I've run into issues in the past where our deployment team has deployed BizTalk applications to one of our environments using the wrong bindings, leaving us with two receive locations pointing to the same file share (i.e. both dev and test servers point to dev receive location uri). When this occurs, the two environments in question tend to take turns processing the files received (meaning if I am attempting to debug something in one environment and the other environment has picked the file up, it looks as if my test file has disappeared into thin air). We have several different environments, plus individual developer machines, and I'd rather not have to check each individually to find the culprit. I'm looking for a quick way to detect what locations are connected to the share once I notice my test files vanishing. If I can determine the connections that are invalid, I can go directly to the person responsible for that environment and avoid the time it takes to randomly ask around. Or if the connections appear to be correct, I can go directly to troubleshooting where in the process the message gets lost. Any suggestions?

    Read the article

  • HD working with IDE USB adapter but not recognised by bios

    - by Rajeeva
    I have a Windows XP Pentium III desktop with two hard drives. The first one has the OS and is luckily working. The second drive on the secondary master IDE channel few days back was unable to read some files and since then for some time it was failing and reviving intermittently and now it is always showing as failed on the IDE channel When the HD was intermittenly failing, I was able to copy some data from it to the other drive - also during that time if the system was running and the hard disk failed at that time, the system froze and then i had to reboot. then I got a new 80 gb hdd similar (same make - seagate barracuda) to the earlier failing one, a new data cable for the drive and an IDE to USB adapter. the new hard drive i installed in the previous drive's place (secondary master), formatted it and it worked for 1 day and then it also failed - simultaneously i connected the old hd to the IDE/USB adapter and i could view all the data - some of that data i was able to back up from the old hd to the new hd before the new hd failed the new hd i have tried connecting on the primary channel as the slave disk but when i do that then the bios does not detect either the OS drive or the new drive and the system does not boot surprisingly, the older (previously failed) hd and the new hd are both working fine on the usb channel with the IDE/USB adapter. i have ruled out any problem with the secondary channel since the dvd rom i was earlier using as primary slave have now connected to secondary master and it works fine. i am really confused by this behavior on my system. please can anybody try to solve this for me. thanks.

    Read the article

  • Why is my rsync so slow?

    - by iblue
    My Laptop and my workstation are both connected to a Gigabit Switch. Both are running Linux. But when I copy files with rsync, it performs badly. I get about 22 MB/s. Shouldn't I theoretically get about 125 MB/s? What is the limiting factor here? EDIT: I conducted some experiments. Write performance on the laptop The laptop has a xfs filesystem with full disk encryption. It uses aes-cbc-essiv:sha256 cipher mode with 256 bits key length. Disk write performance is 58.8 MB/s. iblue@nerdpol:~$ LANG=C dd if=/dev/zero of=test.img bs=1M count=1024 1073741824 Bytes (1.1 GB) copied, 18.2735 s, 58.8 MB/s Read performance on the workstation The files I copied are on a software RAID-5 over 5 HDDs. On top of the raid is a lvm. The volume itself is encrypted with the same cipher. The workstation has a FX-8150 cpu that has a native AES-NI instruction set which speeds up encryption. Disk read performance is 256 MB/s (cache was cold). iblue@raven:/mnt/bytemachine/imgs$ dd if=backup-1333796266.tar.bz2 of=/dev/null bs=1M 10213172008 bytes (10 GB) copied, 39.8882 s, 256 MB/s Network performance I ran iperf between the two clients. Network performance is 939 Mbit/s iblue@raven $ iperf -c 94.135.XXX ------------------------------------------------------------ Client connecting to 94.135.XXX, TCP port 5001 TCP window size: 23.2 KByte (default) ------------------------------------------------------------ [ 3] local 94.135.XXX port 59385 connected with 94.135.YYY port 5001 [ ID] Interval Transfer Bandwidth [ 3] 0.0-10.0 sec 1.09 GBytes 939 Mbits/sec

    Read the article

  • How would I write a terminal command to download a folder with wget from a Media Temple (gs) server?

    - by racl101
    I'm trying to download a folder using wget on the Terminal (I'm usin a Mac if that matters) because my ftp client sucks and keeps timing out. It doesn't stay connected for long. So I was wondering if I could use wget to connect via ftp protocol to the server to download the directory in question. I have searched around in the internet for this and have attempted to write the command but it keeps failing. So assuming the following: ftp username is: [email protected] ftp host is: ftp.s12345.gridserver.com ftp password is: somepassword I have tried to write the command in the following ways: wget -r ftp://[email protected]:[email protected]/path/to/desired/folder/ wget -r ftp://serveradmin:[email protected]/path/to/desired/folder/ When I try the first way I get this error: Bad port number. When I try the second way I get a little further but I get this error: Resolving s12345.gridserver.com... 71.46.226.79 Connecting to s12345.gridserver.com|71.46.226.79|:21... connected. Logging in as serveradmin ... Login incorrect. What could I be doing wrong?

    Read the article

  • Windows 7: Dual Monitor Issue

    - by sdoca
    I have a Dell laptop with a docking station and two external monitors hooked up. I'm running Windows 7 64 bit. Originally, the two monitors were the same - Dell 1908FP. I have replaced one of them with an HP LA2405. I have set the HP 24" (1920 x 1200 connected via DVI port) as montior 1 and extended to use the Dell 19" (12080 x 1024 connected via VGA port) as monitor 2. I have set my power plan so that when the laptop is plugged in, it will turn the monitors off after 10 minutes, but it will not put my laptop to sleep. However, now that I have the HP monitor, when I unlock my laptop and the monitors come back on, all my windows are resized and shifted to the top left corner of the HP monitor as if they had been resized for display on the smaller Dell monitor. A co-worker has the exact same laptop and monitor configuration but doesn't experience this issue, so I figure there's some configuration that's different but we can't find it. I haven't been able to find any mention of a similar problem doing an internet search, but I'm not really sure what terms to use in my search. Anybody have any suggestions as to what may be causing the issue? OS setting? Monitor setting? EDIT: My laptop is using the Intel Graphics and Media Control Panel/drivers.

    Read the article

  • 2 Computers, same network, different outgoing speeds when uploading to internet?

    - by user117339
    I have 2 work machines in my office, a PowerMac G5 and a MacBook Air. Both behind an IPCop firewall. The PowerMac is connected through a gigabit switch, the MacBook Air is connected through a Netgear 802.11g access point that is then plugged into the gigabit switch. There is also a FreeNAS box, both machines are able to read and write files to it at close to their pipe speeds. The main problem is when I am trying to upload files to the internet at large. The G5 is only hitting 0.1 - 0.25 Mbps. The Macbook is able to hit 2-3 Mbps. The setup (G5 / IPCop / Network) has been the same for 5 years. The issues with the internet speed started about 3 months ago. I hadn't tested on the Macbook at this point. I had complained to the ISP, they said their modem needed a firmware update, did that nothing changed. Reset IPCop, turned off squid, etc. No changes. The ISP switched the office over to a better plan with a theoretical 6 Mbps up, still no change. At this point I tried testing the Macbook, and lo and behold there's the speed. But why? I have tried changing out everything, cables, switches, using another ethernet port on the G5, wiping the system, using DHCP, using manual IPs, changing DNS servers, etc. Nothing works. I figured that if there was something horribly wrong with the network, then internally I would find a similar issue, but that is perfect. iperf, ping, etc show no dropped packets and near saturation of the internal network. I'm at a loss as to what the heck is going on. Any ideas would be appreciated! Below are some screenshots of speedtest.net: G5: Macbook Air:

    Read the article

  • 412 Precodition Failed error only occurs on certain networks

    - by Andy
    One of my favorite websites: http://jessiejofficial.com (yes, I'm a Jessie J Fan :')) has recently started displaying the error message "412 Precondition Failed" whenever I visit it from my home network, even when I use Tor Browser. At first I thought that this was an issue with the whole website, however I have contacted the web developer and he has said that they has been plenty of hits within the last 48 hours. Plus, I discovered tonight that I can access the website from my phone, through the mobile network. So it appears to just be my network as all of the devices in my house connected to the WiFi display the same error when I try to visit any page of the site. However there have been no changes that we are aware of or are noticeable to our network since the website was accessible, and I have just heard that another person in a different part of the country is experiencing the same difficulties also. Any help/advice/suggestions would be appreciated greatly Update: When trying to ping 'jessiejofficial.com' in Windows command prompt the request times out on all four attempts, on any computer connected to the wireless network. I can now also confirm that the same thing occurs on my MacBook Pro.

    Read the article

  • Many clients on a wireless AP for UDP broadcast packets

    - by distorteddisco
    I asked this question on StackOverflow and was directed over here, so I'd appreciate any advice. I'm deploying a smartphone application as part of a live music performance that depends on receiving UDP broadcast packets from a wireless access point. I'm guessing that between 20 and 50 clients will be connected at any one time. I'm aware that a maximum of 20 clients per access point is advised, but as the UDP broadcast packets are ground through the LAN, how would I be able to link multiple APs together? I'm looking for recommendations on a suitable AP for this. The actual data transmission rates are very low - only a few kB/s - as I'm just sending small messages to the smartphone apps, and there will be no WAN internet connection. I tried it with a few connected peers on an adhoc wireless connection without any problems, but ran into dropped packet issues on an old WRT54G running ddwrt, though it's in pretty rough shape. What's the best way to do this? I suppose I could limit concurrent wireless connections to 20 clients... but more would be nice. EDIT: I should also say that it's purely one-way communication; the smartphone application is only receiving broadcast packets, not sending anything.

    Read the article

  • DVI output _only_ working on Windows, not during booting or on Linux

    - by Mononofu
    So yesterday I booted my laptop up and the external monitor I have it connected to just stayed black. At first, I thought the problem would go away when Ubuntu was loaded, but it didn't. I tried to reboot a few times, to no avail. Then I decided to give Windows 7 a try, and suddenly (at the login-screen), my external monitor turned on and worked like normal. I have connected the monitor via DVI, and this only seems to work with Windows now. I don't even get a signal in my BIOS! Mind you, everything was working fine before that, and I didn't change a single thing. I then tried to connect the monitor via VGA (from my DVI jack, which can output VGA using an adaptor), and it worked again. However, 1920x1200 using VGA looks like crap - black print on white background is basically illegible. Do you have any ideas how to fix this peculiar problem? I only use windows for gaming, so it's no real help that it still works normally. Please also excuse any spelling mistakes, I am practically typing this blindly. Edit: I only have one graphics card in my laptop, and I can't select anything related to that in my BIOS. In fact, I can pretty much do almost nothing there. My laptop is a Nexoc Osiris E703, graphics gard is a GeForce Go 7900 GTX. As I mentioned before, DVI output during booting and on Ubuntu was working fine for years before yesterday!

    Read the article

  • Can you help me understand my SATA/RAID options?

    - by andrz_001
    I've a gigabyte GA-M720-US3 motherboard. Recently, I noticed the following during boot: IDE channel 0 Master (none) IDE channel 0 Slave (none) IDE channel 2 Master (my hdd) IDE channel 2 Slave (my dvd drive) IDE channel 3 Master (none) IDE channel 3 Slave (none) Of course, the same information is contained in the BIOS/CMOS. The HDD is connected to the mobo via a SATA(2?) cable at the port(?) labeled SATA2_0. The DVD drive is connected by a similar cable at SATA2_1. Why doesn't the information displayed during the boot and in BIOS reflect how I plugged the cables in? I mean, why "none" for channel 0 when there is something in SATA2_0. (or is that serious naivete on my part!?) Where's Channel 1 master and slave? Since these are SATA cables and not the IDE ribbons from a time ago, why the whole master/slave declaration during boot and in BIOS? Should my BIOS reflect the fact that these are SATA cables? I mean, in BIOS, should the "Onchip SATA mode IDE" be set to RAID or AHCI instead of IDE? Any replies, answers, suggestions, links, tips will be much appreciated. Thank you in advance!

    Read the article

  • Can only ssh when not using wifi

    - by AChrapko
    So I have 3 machines, a windows 7 desktop that is always wired to my router, osX laptop, and raspberry pi running debian linux. My router is a Linksys e1000 wireless N. My goal is to be able to ssh the raspi from any machine, while it is connected via wifi. My problem is that when trying to ssh from either the win7 or osX to the Pi it either times out, or gives an error: "ssh: connect to host 192.168.1.### port 22: No route to host" The only times that I have managed to connect to the pi from any machine were when it connected to the router via an Ethernet cable. Currently with win7 desktop wired, macbook wireless, and pi wireless tests give the following: win7 ping macbook: Destination host unreachable. macbook ping win7: Request timeout. win7 ping pi: Destination host unreachable. macbook ping pi: Request timeout. blah blah blah Plugging the macbook into the router with an Ethernet cable all communication between win7 and macbook works. Pings, ssh, ftp, smb ect... No changes to the pi, still no connections possible to or from any of the other 2 machines. Note All machines, are able to connect to the internet and ssh to the same machine on a completely different network, wired or over wifi. Plugging the Pi in with Ethernet (and macbook still wired) I can ssh to the pi from both win7 and macbook. I can ssh from the pi to macbook. All machines still able to connect the the off network machine. Also another little side note- I was playing warcraft 3 with my roommates the other day, and the only time they were able to see my LAN game was when they were plugged into the router with an Ethernet cable. Once or twice one of the laptops was able to connect over wifi, but not without another computer connecting first via Ethernet. So basically does anyone have any info as to why my router seems to completely ignore local wireless traffic?

    Read the article

  • Could 0x800CCC0E in Outlook be caused by bad wireless connection?

    - by AndrejaKo
    I have a computer connected to a WiFi access point/router/modem. Sometimes, I get page not found errors and similar when opening a browser window, sometimes pings fail and it looks like the router's signal isn't very good. On the other hand, I get around 4 bars of signal strength in windows and graph looks good in Inssider. I also never get dropped connection to the router. My main problem is that I often get errors (such as 0x800CCC0E) in Outlook 2010 that after some searching appear to be connected to bad server connection. I'm using GMail over IMAP and all settings are correct. I didn't have similar errors on my previous router, but I'm not 100% sure that they appeared after switching to current one. It may have worked for some time without errors. There are also around 3000 messages on the server and the size of mailbox is around 12 GiB, which may contribute to the problems. On the other hand, there are at least 24 other networks in the 2.4 GHz range which I'm using and the number may have increased since I switched routers. Should I try solving this by getting a router with stronger signal?

    Read the article

< Previous Page | 72 73 74 75 76 77 78 79 80 81 82 83  | Next Page >