  • How to block some disks from probes on Linux boot?

    - by Igor Velkov
    My linux host connected to SAN with FC interface. It connect with one path, and see some luns, that can't access, because they need anohter path, not available to host. On boot linux probe all lun he can see, get read error on unaccessible luns, and hangs there for a long-long time. Is there a way to disable any access to some luns at boot time, and later? I found a filters for device ignoration for LVM and MULTIPATH, but it not help during boot process. Generally, lvm still affected too despite of filter, and gives me a IO error on every operation like lvdisplay and vgdisplay, but this is another question.

    Read the article

  • Home ZFS based NAS...What processor/chipset to use?

    - by MrBlargityBlarg
    So, I'm building a home/personal NAS. My plan is to expose both SMB fileshares for sharing files/media between hosts, but also to carve an iSCSI target LUN out of it for use by VMWare as a datastore. I want to use ZFS (software RAID) so that means I'll either be using FreeNAS, Solaris Express, or OpenIndiana. My question is basically: How much horsepower do I need? Obviously I/O is going to be my bottleneck but I want to be sure that I am not limiting my I/O because of a slow processor or chipset. So far the hardware plan is to use an Intel i3 and motherboard with one of the H87, Q87, or Z87 chipsets, a SAS controller (JBOD, no RAID) and if budget allows, I'm also hoping to get an SSD for the ZFS L2ARC and ZIL. Does anyone think I could get away with an Intel Atom or cheaper/less-capable processor/chipset than the i3 and [HQZ]87 listed above?

    Read the article

  • ZFS: Redistribute zvol over all disks in the zpool?

    - by growse
    Is there a way in which ZFS can be prompted to redistribute a given filesystem over the all of the disks in its zpool? I'm thinking of a scenario where I have a fixed size ZFS volume that's exported as a LUN over FC. The current zpool is small, just two 1TB mirrored disks, and the zvol is 750GB in total. If I were to suddenly expand the size of the zpool to, say, 12 1TB disks, I believe the zvol would still effectively be 'housed' on the first two spindles only. Given that more spindles = more IOPS, what method could I use to 'redistribute' the zvol over all 12 spindles to take advantage of them?

    Read the article

  • (simple) linux HA with vmware vsphere?

    - by derhelge
    I hope my upcoming question is specific enough, and you are able and willing to support :-) We have several openSUSE VMs in an ESX-Cluster (three ESX-Servers) with an attached iSCSI-SAN. All of those Linux VMs are "single point of failure"-configured, which means in the case of a Web-Server: LAMP, storage, etc. everything on this machine. This was very simple and in case of a failure (in the last years: kernel panics or apache crashes) a simple reboot triggered by a script did it. But the problem is: How to upgrade/maintain the w(eb-)application or the underlying OS without downtime? This wasn't really managable and i did this in the early morning ;) How can i achieve a "simple" High-Availability Cluster now? I thought of: DRBD with heartbeat with 2 VMs. And for the storage a RDM (raw device mapped) LUN and change the read-write-permissions for both VMs. Is this a good idea? Anyone has a better solution?

    Read the article

  • Linux stretch cluster: MD replication, DRBD or Veritas?

    - by PieterB
    For the moment there's a lot of choices for setting up a Linux cluster. For cluster manager: you can use Red Hat Cluster manager, Pacemaker or Veritas Cluster Server. The first one has the most momentum, the second one comes by default with RH subscriptions and the last one is very expensive and has a very good reputation ;-) For storage: - You can replicate LUN's using software raid / md device - You can use the network using DRBD replication, which offers a bit more flexibility - You can use Veritas Storage Foundation technology to talk to your SANs replication technology. Anyone has any recommandations or experience with these technologies?

    Read the article

  • What is "2LUN" mode in connection with RAID?

    - by naxa
    I've came across RAID products that also list JBOD (just a bunch of disks) mode and 2LUN mode. What the heck is 2LUN mode? I could not find a description; the closest thing seems to be LUN 'logical unit number' but I don't get the 2LUN thing. UPDATE 1 This is what Wikipedia has to say about JBOD: JBOD (derived from "just a bunch of disks"): an architecture involving multiple hard drives, while making them accessible either as independent hard drives, or as a combined (spanned) single logical volume with no actual RAID functionality. So JBOD can actually mean two different (albeit related) things. Answer of Guest says 2LUN means no spanning. Does this suggest that 2LUN would simply mean the JBOD-variant with no span?

    Read the article

  • Linux stretch cluster: MD replication, DRBD or Veritas?

    - by PieterB
    For the moment there's a lot of choices for setting up a Linux cluster. For cluster manager: you can use Red Hat Cluster manager, Pacemaker or Veritas Cluster Server. The first one has the most momentum, the second one comes by default with RH subscriptions and the last one is very expensive and has a very good reputation ;-) For storage: - You can replicate LUN's using software raid / md device - You can use the network using DRBD replication, which offers a bit more flexibility - You can use Veritas Storage Foundation technology to talk to your SANs replication technology. Anyone has any recommandations or experience with these technologies?

    Read the article

  • Shared FC LVM VG with LVs for each KVM VM. Clvm required?

    - by Cocoabean
    I have 2 virtual machine hosts running Ubuntu 12.04 and KVM managed with libvirt. They are both connected to the same VG which is a LUN on my SAN over FC. I provision LVs on this shared VG for each VM. I don't think I need HA or failover, but I do want live migration between the hosts. Do I need clvm in this case? As long as I don't try to start the same VM on each host should this work? Clvm requires lots of overhead with clustering tools that I don't think I need. I can deal with manually restarting VMs on other hosts in the event of a hardware failure.

    Read the article

  • Provision storage in SAN encironment

    - by wildchild
    hi,.. Can somebody help in understanding how Lun Provisioning is done in clariion based on client requirement. Say, a client needs one 50 GB space on the host( for application) ,two -350 GBs ( for DB and stuff) on the same host and i have 4 raid groups with space of 200 GB in one 50 GB in second and 400 GB and 400GB in rest two all having 5 disks. And , I 'm using Raid 5 only. How do i provision keeping performance in mind( so that performance hit is not there)?..And i need to understand the concept of meta head as well. Please help me by elaborating the above scenario..I am learning to provision storage in non productive environment( b'fore going ahead and working on client prod server) and i have been learning a lot from SF ...I request the seniors here to help me understand it better. Thanks for reading

    Read the article

  • XenServer/Center: Shared SRs for hosts not in same pool?

    - by 3molo
    I would like to use the same SRs on XenServer hosts that are not able to be part of the same pool (because of not having the exact same cpu feature set, if I understand it correctly) in order to share templates, being able to (manually) start a host on another node, backing up running hosts on other hardware etc etc. The technology for SR can be any of iSCSI, NFS or CIFS, iSCSI would obviously be preferred. Trying to add an iSCSI volume renders a "This LUN is already in use as SR iSCSI - Shared Storage on pool xxxxxx.". Adding a NFS share on one XS host, creating a template there and then checking another XS host reveals they don't agree on used space etc. Coming from a vSphere world this is quite baffling, but if these are limitations then I will have to rethink some of the concepts for this low budget project.

    Read the article

  • Same SCSI drive appears multiple times on the controller list

    - by ohad
    Hi, I have an Adaptec AHA-2940UW SCSI adapter, to which I connected a single Atlas 10K III drive (and nothing more). When my computer loads up, the pre-OS Adaptec screen shows (I believe this is called the POST screen), where I can see the Atlas drive listed many times (i.e. with ID0, ID1, ... ID5, ID7, ID8,...,ID15 [ID6 is the adapter itself]) Using the same HD on an Adaptec AHA-2940UB the disk only shows once Since my OS hasn't been installed yet, I'm not sure if this is a problem (I would guess it is), and if so - how to solve it. Termination and multiple LUNs come mind, but the cable provides termination and I don't see why a hard drive would request multiple LUNs, especially considering it is not jumpered at all, and multuple LUN support is disabled in the Adaptec controller BIOS (via the SCSISelect utility) Thank you

    Read the article

  • RHEL raw device (over VMware RDM) performance issues

    - by jifa
    I'm running RHEL 5.3 over vSphere 4.0U1. I configured multiple LUNs on my NetApp (Fibre) storage, and added the RDM on two (Linux) VMs, using the Paravirtual SCSI adapter. One LUN is 100GB in size, successfully mapped to /dev/sdb on both VMs, 5 more are 500MB in size (mapped to /dev/sd{c-g}. I also created one partition per device. I have encountered two issues: First, writing directly to /dev/sdb1 gives me ~50MB/s, while any of the /dev/sd{c-g}1 gives me ~9MB/s. There is no difference in configuration of the LUNs apart from their size. I am wondering what causes this but this is not my main problem, as I would settle for 9 MB/s. I created raw devices using udev pretty straightforwardly: ACTION=="add", KERNEL=="sdb1", RUN+="/bin/raw /dev/raw/raw1 %N" per device Writing to any of the new raw devices dramatically slows down performance to just over 900KB/s. Can anyone point me in a helpful direction? Thanks in advance, -- jifa

    Read the article

  • How to interpret IOZone results?

    - by homer5439
    Here are the resuts of running IOZone on an ext3 filesystem on an LVM volume residing on a SAN LUN (it was ran with 5 parallel processes). "Throughput report Y-axis is type of test X-axis is number of processes" "Record size = 4 Kbytes " "Output is in Kbytes/sec" " Initial write " 81628.55 " Rewrite " 83354.72 " Read " 115595.02 " Re-read " 119306.09 " Reverse Read " 47684.20 " Stride read " 10011.09 " Random read " 16751.27 " Mixed workload " 5659.77 " Random write " 1661.85 " Pwrite " 36030.83 Now this is all nice and dandy, but my question is: how do I know whether the values are as good as they could be or there is something to tweak (and if so, what?) The actual usage I will have for that Logical Volume is to act as virtual disk for a VM.

    Read the article

  • USB sector 0 not fount Kingston USB DT100 G2

    - by java
    Windows constantly asks me "Foramt Disk". when i go to command prompt and type format H: /fs:ntfs or format H: /fs:fat32 response: Cannot determine the number of sectors on this volume. if the benefit DISKPART detail disk Kingston DT 100 G2 USB Device Disk ID: 00000000 Type : USB Status : Online Path : 0 Target : 0 LUN ID : 0 Location Path : UNAVAILABLE Current Read-only State : No Read-only : No Boot Disk : No Pagefile Disk : No Hibernation File Disk : No Crashdump Disk : No Clustered Disk : No DISKPART detail volume Read-only : No Hidden : No No Default Drive Letter: No Shadow Copy : No Offline : No BitLocker Encrypted : No Installable : No Volume Capacity : 0 B Volume Free Space : 0 B what the problem?

    Read the article

  • Windows 2003 Server - Can I map a folder to another folder on the same server?

    - by TheCleaner
    Scenario: I have a server that was running low on space. We have an external iscsi SAN that it now has a LUN on and connected to the server as E:\ We are moving the PHOTOS folder from the old location on D:\ to the new E:. That new drive is being shared out as "ARCHIVE". So: \server\shared\photos now becomes \server\archive\photos I can easily place a shortcut in the original location saying "DOUBLE CLICK HERE FOR THE PHOTOS", but it isn't ideal. What I'd like is to be able to have \server\shared\photos simply point to \server\archive\photos. So that if someone wants to map a drive to \server\shared and then browse to the photos folder once in there they will see what is in the \server\archive\photos location. Is that possible? I was thinking about SUBST or DFS, but I don't think either of those will do it.

    Read the article

  • Backup tape compression

    - by pufferfish
    What things should I check to confirm that compression is actually happening on our tape backup system? Although the tapes are marked as 200G/520G (native/compressed) capacity, they seem to fill up before the 200G mark (some less than 100G). I'm using - Sony AIT-4 tape autochanger - Sony SDX4-200C (AIT-4) tapes - Ubuntu Lucid - Bacula I've tried checking hardware compression with: tapeinfo -f /dev/nst0, which gives Product Type: Tape Drive Vendor ID: 'SONY ' Product ID: 'SDX-900V ' Revision: '0102' Attached Changer API: No SerialNumber: '0001000036' MinBlock: 2 MaxBlock: 8388608 SCSI ID: 1 SCSI LUN: 0 Ready: yes BufferedMode: yes Medium Type: Not Loaded Density Code: 0x33 BlockSize: 0 DataCompEnabled: yes DataCompCapable: yes DataDeCompEnabled: yes CompType: 0x3 DeCompType: 0x3 BOP: yes Block Position: 0 Partition 0 Remaining Kbytes: 201778000 Partition 0 Size in Kbytes: 201779000 ActivePartition: 0 EarlyWarningSize: 0 NumPartitions: 0 MaxPartitions: 0 ... so I presume it's on. Notes: The Bacula documentation says hardware compression needs to be enable with "system tools such as mt"

    Read the article

  • Esxi with iSCSI SAN slows down with many multiple VMs running

    - by varesa
    I have a server with ESXi 5 and iSCSI attached network storage(4x1Tb Raid-Z on freenas). Those two machines are connected to each other with Gigabit ethernet, and a procurve switch in between. After a while, if I have many(4-5 or more) vms running, they start to get un-responsive (long delays before anything happens). We are trying to find the reason behind this. Today we looked at esxtop, and found that DAVG of that iSCSI LUN stays at 70-80. I read that +30 is critical! What could be causing those high response-times?

    Read the article

  • ISCSI sessions appear from nowhere

    - by Maraca
    Hi, I am using Win2008 32bit Ent. running in Hyper-V with 2 LUNs over ISCSI connection (this is a MS cluster with one LUN being quorum and second as a storage). In ISCSI - target - details I see multiple sessions from same target (currently 7), however I am not sure where they are coming from as I have only one virtual NIC on this server. Sure enough 2 LUNs appear 7 times each in device manager or in disk manager. On the cluster partner however, I do not see that problem. There is only one session per target. Installing MPIO makes only difference - I am getting 8 sessions instead of 7 once I reboot. Does any one know what can cause this behavior?

    Read the article

  • OSX : Setup for filestorage in medium business

    - by Franatique
    In our office every machine runs OSX. In search of an ideal storage and sharing solution we decided to let OSX Server handle all account information and auth requests whereas an 7TB QNAP provides NFS shares. All shares are published as mounts in the companywide LDAP. As it turns out, handling permissions in this situation is very clumsy (e.g. inherit permissions on newly created files). Unfortunately using NFS4 in combination with ACLs did not solve the problem. As a possible solution I set up a iSCSI connection between QNAP and the machine running OSX Server which in turn serves the LUN as AFP share. Permission handling works like a charm for this setup. Although I am a bit concerned about the performance of this setup. As we are a fast growing company we expect the solution to serve at least 100 clients while using files aprox. above 100MB each. Are there any known drawbacks of this solution?

    Read the article

  • New Hands-On Labs For Oracle VM

    - by rickramsey
    I just spent some time walking through the labs that Christophe Pauliat and Olivier Canonge prepared to help you become familiar with Oracle VM. They are terrific. We will offer them for the first time at Oracle Open World. Because they require some pre-work and 16Gigs of memory, we are supplying the laptops for the participants. Lab 1: Deploying Infrastructure as a Service with Oracle VM Session ID: HOL9558 Tuesday October 2nd, 2012 10:15am – 11:15am Marriott Marquis - Salon 14/15 Planning and deployment of an infrastructure as a service (IaaS) environment with Oracle VM as the foundation. Storage capacity planning, LUN creation, network bandwidth planning, and best practices for designing and streamlining the environment so that it's easy to manage. Lab 2: Virtualize and Deploy Oracle Applications Using Oracle VM Templates Session ID: HOL9559 Tuesday October 2nd, 2012 11:45am – 12:45pm Marriott Marquis - Salon 14/15 How to deploy Oracle applications in minutes with Oracle VM Templates. Step-by-step lab proctored by field-experienced engineers and product experts. Covers: Find out what Oracle VM Templates are and how they work Deploy an actual Oracle VM Template for an Oracle Application Plan your deployment to streamline on going updates and upgrades Lab 3: x86 Enterprise Cloud Infrastructure with Oracle VM 3.x and Sun ZFS Storage Appliance Session ID: HOL 9870 Wednesday, 3 Oct, 2012 5:00 PM - 6:00 PM Marriott Marquis - Salon 14/15 This hands-on lab will demonstrate what Oracle’s enterprise cloud infrastructure for x86 can do, and how it works with Oracle VM 3.x. It covers: How to create VMs How to migrate VMs How to deploy Oracle applications quickly and easily with Oracle VM Templates How to use the Storage Connect plug-in for the Sun ZFS Storage Appliance Additional Virtualization Resources for Sysadmins Technical articles about virtualization Other resources about Oracle virtualization technologies More information about Oracle Open World. - Rick Website Newsletter Facebook Twitter

    Read the article

  • Screen Aspect Ratio

    - by Bill Evjen
    Jeffrey Dean, Pixar Aspect Ratio is very important to home video. What is aspect ratio – the ratio from the height to the width 2.35:1 The image is 2.35 times wide as it is high Pixar uses this for half of our movies This is called a widescreen image When modified to fit your television screen They cut this to fit the box of your screen When a comparison is made huge chunks of picture is missing It is harder to find what is going on when these pieces are missing The whole is greater than the pieces themselves. If you are missing pieces – you are missing the movie The soul and the mood is in the film shots. Cutting it to fit a screen, you are losing 30% of the movie Why different aspect ratios? Film before the 1950s 1.33:1 Academy Standard There were all aspects of images though. There was no standard. Thomas Edison developed projecting images onto a wall/screen He didn’t patent it as he saw no value in it. Then 1.37:1 came about to add a strip of sound This is the same size as a 35mm film Around 1952 – TV comes along NTSC Television followed the Academy Standard (4x3) Once TV came out, movie theater attendance plummets So Film brought forth color to combat this. Also early 3D Also Widescreen was brought forth. Cinema-Scope Studios at the time made movies bigger and bigger There was a Napoleon movie that was actually 4x1 … really wide. 1.85:1 Academy Flat 2.35:1 Anamorphic Scope (aka Panavision/Cinemascope) Almost all movies are made in these two aspect ratios Pixar has done half in one and half in the other Why choose one over the other? Artist choice It is part of the story the director wants to tell Can we preserve the story outside of the theaters? TVs before 1998 – they were very square Now TVs are very wide Historical options Toy Story released as it was and people cut it in a way that wasn’t liked by the studio Pan and Scan is another option Cut and then scan left or right depending on where the action is Frame Height Pixar can go back and animate more picture to account for the bottom/top bars. You end up with more sky and more ground The characters seem to get lost in the picture You lose what the director original intended Re-staging For animated movies, you can move characters around – restage the scene. It is a new completely different version of the film This is the best possible option that Pixar came up with They have stopped doing this really as the demand as pretty much dropped off Why not 1.33 today? There has been an evolution of taste and demands. VHS is a linear item The focus is about portability and not about quality Most was pan and scan and the quality was so bad – but people didn’t notice DVD was introduced in 1996 You could have more content – two versions of the film You could have the widescreen version and the 1.33 version People realized that they are seeing more of the movie with the widescreen High Def Televisions (16x9 monitors) This was introduced in 2005 Blu-ray Disc was introduced in 2006 This is all widescreen You cannot find a square TV anymore TVs are roughly 1.85:1 aspect ratio There is a change in demand Users are used to black bars and are used to widescreen Users are educated now What’s next for in-flight entertainment? High Def IFE Personal Electronic Devices 3D inflight

    Read the article

  • Oracle's PeopleSoft Customer Advisory Boards Convene to Discuss Roadmap at Pleasanton Campus

    - by john.webb(at)oracle.com
    Last week we hosted all of the PeopleSoft CABs (Customer Advisory Boards) at our Pleasanton Development Center to review our detailed designs for future Feature Packs, PeopleSoft 9.2, and beyond. Over 150 customers from 79 companies attended representing a variety of industries, geographies, and company sizes. The PeopleSoft team relies heavily on this group to provide key input on our roadmap for applications as well as technology direction. A good product strategy is one part well thought out idea with many handfuls of customer validation, and very often our best ideas originate from these customer discussions. While the individual CABs have frequent interactions with our teams, it's always great to have all of them in one place and in person. Our attendance was up from last year which I attribute to two things: (1) More interest as a result of PeopleSoft 9.1 upgrade; (2) An improving economy allowing for more travel. Maybe we should index the second item meeting-to-meeting and use it as a market indicator - we'll see! We kicked off the day one session with an overview of the PeopleSoft Roadmap and I outlined our strategy around Feature Packs and PeopleSoft 9.2. Given the high adoption rate of PeopleSoft 9.1 (over 4x that of 9.0 given the same time lapse since the release date), there was a lot of interest around the 9.1 Feature Packs as a vehicle for continuous value. We provided examples of our 3 central design themes: Simplicity, Productivity, and lower TCO, including those already delivered via Feature Packs in 2010. A great example of this is the Company Directory feature in PeopleSoft HCM. The configuration capabilities and the new actionable links our CAB advised us on last Spring were made available to all customers late last year. We reviewed many more future Navigation changes that will fundamentally change the way users interact with PeopleSoft. Our old friend, the menu tree, is being relegated from center stage to a bit part, with new concepts like Activity Guides, Train Stops, Related Actions, Work Centers, Collaborative Workspaces, and Secure Enterprise Search bringing users what they need in a contextual, role based manner with fewer clicks. Paco Aubrejuan, our PeopleSoft GM, and Steve Miranda, the SVP for Fusion Applications, then discussed our plans around Oracle's Application Investment Strategy.  This included our continued investment in developing both PeopleSoft and Fusion as well as the co-existence strategy with new Fusion Apps integrating to PeopleSoft Apps. Should you want to view this presentation, a recording is available. Jeff Robbins, our lead PeopleTools Strategist, provided the roadmap for PeopleTools and discussed our continuing plan to deliver annual releases to further evolve the user experience. Numerous examples were highlighted with the Navigation techniques I mentioned previously. Jeff also provided a lot of food for thought around Lifecycle Management topics and how to remain current on releases with a  lower cost of ownership. Dennis Mesler, from Boise, was the guest speaker in this slot, who spoke about the new PeopleSoft Test Framework (PTF). Regression Testing is a key cost component when product updates are applied. This new tool (which is free to all PeopleSoft customers as part of PeopleTools 8.51) provides a meta data driven approach to recording and executing test scripts. Coupled with what our Usage Monitor enables, PTF provides our customers a powerful tool to lower costs and manage product updates more efficiently and at the time of their choosing. Beyond the general session, we broke out into the individual CABs: HCM, Financials, ESA/ALM, SRM, SCM, CRM, and PeopleTools/ Technology. A day and half of very engaging discussions around our plans took place for each product pillar. More about that to follow in future posts.      We capped the first day with a reception sponsored by our partners: InfoSys, SmartERP (represented by Doris Wong), and Grey Sparling  Solutions (represented by Chris Heller and Larry Grey). Great to see these old friends actively engaged in the very busy PeopleSoft ecosystem!   Jeff Robbins previews the roadmap for PeopleTools with the PeopleSoft CAB  

    Read the article

  • RHEL 5 SCSI ADPATEC

    - by Rajiv Sharma
    HI I have RHEL 5 box . and adpatec scsi card connected to it . I can see the adaptor under dsmeg | grep -i scsi dmesg | grep -i scsi SCSI subsystem initialized scsi0 : SCSI emulation for USB Mass Storage devices Type: CD-ROM ANSI SCSI revision: 00 scsi 0:0:0:0: Attached scsi generic sg0 type 5 sr0: scsi3-mmc drive: 0x/0x caddy sr 0:0:0:0: Attached scsi CD-ROM sr0 scsi1 : Adaptec AIC79XX PCI-X SCSI HBA DRIVER, Rev 3.0 aic7901: Ultra320 Wide Channel A, SCSI Id=7, PCI-X 101-133Mhz, 512 SCBs Loading iSCSI transport class v2.0-871. iscsi: registered transport (iser) iscsi: registered transport (cxgb3i) Broadcom NetXtreme II iSCSI Driver bnx2i v2.1.0 (Dec 06, 2009) iscsi: registered transport (bnx2i) scsi2 : Broadcom Offload iSCSI Initiator scsi3 : Broadcom Offload iSCSI Initiator iscsi: registered transport (tcp) iscsi: registered transport (be2iscsi) bnx2i: iSCSI not supported, dev=eth0 bnx2i: iSCSI not supported, dev=eth0 bnx2i: iSCSI not supported, dev=eth1 bnx2i: iSCSI not supported, dev=eth1 but cann't see under cat /proc/scsi/scsi cat /proc/scsi/scsi Attached devices: Host: scsi0 Channel: 00 Id: 00 Lun: 00 Vendor: KVM Model: vmDisk-CD Rev: 0.01 Type: CD-ROM ANSI SCSI revision: 02 all st and sg modules are enable. Anyone please help me thanks advance Rajiv

    Read the article

  • Exam Questions that use .Demand or .LinkDemand COULD NOT BE ANY MORE CONFUSING OR AMBIGIOUS ????

    - by IbrarMumtaz
    I am 110% sure this is WRONG !!!! Q.12) You develop a library, and want to ensure that the functions in the library cannot be either directly or indirectly invoked by applications that are not running on the local intranet. What attribute would you add to each method? A. [UrlIdentityPermission(SecurityAction.RequestRefuse, Url="http://myintranet")] B. [UrlIdentityPermission(SecurityAction.LinkDemand, Url="http://myintranet")] (correct answer) C. [UrlIdentityPermission(SecurityAction.Demand, Url="http://myintranet")] D. [UrlIdentityPermission(SecurityAction.Assert, Url="http://myintranet")] Explanation Link-Demand should be used as it ensures that all callers in the call stack have the necessary permission. In this case it ensures that all callers in the call stack are on the local intranet. There is an indentical question on Transencer so I already had a clue what was goin but Transcender was much more informative that this drivel as it mentioned class level and not assembly level. It also mentioned that some callers maybe coming externally from the company intranet via authroised and authenticated credentials. With information is easy to see why .Demand on would be wong option to go for? So Transcender was right .... so I thgt fine, that makes sense. With think information still fresh in my brain I had a good idea was was going on in the question. To my surprise .Demand was wrong agin !!!! WHAT? I am really starting to hate this setting now? I cannot be any more p*ssed right now!!! :@ Thanks For Reading, Ibrar

    Read the article

  • Programatically create web application & sub site

    - by Tejas
    I am using the following code to programatically create a web application & sub site, try { SPWebApplicationBuilder webAppBuilder = new SPWebApplicationBuilder(SPFarm.Local); SPWebApplication newApplication; int myPort = 3333; webAppBuilder.Port = myPort; //Port No. webAppBuilder.RootDirectory = new System.IO.DirectoryInfo("C:\\Inetpub\\wwwroot\\wss\\VirtualDirectories\\" + myPort); webAppBuilder.CreateNewDatabase = true; // Create new database webAppBuilder.DatabaseName = "WSS_Content_372772890a5a4a04abb460cd9ea3bd22"; // Database name webAppBuilder.DatabaseServer = webAppBuilder.DefaultZoneUri.Host; // DatabaseServer Host name/computer name webAppBuilder.UseNTLMExclusively = true; // Use NTLM authentication newApplication = webAppBuilder.Create(); // Create new web application newApplication.Provision(); // Provision it into web farm using (var mySiteCollection = newApplication.Sites.Add("/", "Site 3", "Site 3 Decscription", 1033, "STS#1", "In-Wai-Svr2\\Administrator", "Administrator", "[email protected]")) { using (var rootWeb = mySiteCollection.RootWeb) { // Code customizing root site goes here using (var subSite = rootWeb.Webs.Add("Site3.1", "Site 3.1", "Site 3.1 Description", 1033, "STS#1", true, false)) { // Code customizing sub site goes here } } } } catch(Exception ex) { ; } It works fine i.e. it creates the web application on the specified port with sub site but this sub site will not be shown under Sites menu of Quick launch bar also it will not be shown as a separate tab on the Home Page. Is it possible to do it programatically?

    Read the article