Search Results

Search found 906 results on 37 pages for 'rebuild'.

Page 8/37 | < Previous Page | 4 5 6 7 8 9 10 11 12 13 14 15  | Next Page >

  • RAID 5 - DELL 2850 and others

    - by Kiara
    I have installed Ubuntu on a DELL 2850 and I have configured an array of 5 disks (SCSI 73GB 10K) in RAID5. I wanted to simulate a drive error so in the middle of something I just took one of the drives out and put it back again after a bit. Then the drive shows an orange light and seems to be rebuilding but actually is taking hours and hours with no results. So I went to the PERC utility (Ctrl+M) and the disk shows "REBLD". But it never gets to an online state. So I went to Objects - Physical drives - Rebuilding - View rebuild process. And in here I can see a bar moving from 0%... but if I reboot before finishing and get into the PERC Utility again, it seems to start again rebuilding from 0% - so it is not rebuilding automatically. My concern is: what would happen in a real situation? Do I have to just switch the server off and go to the Perc utility to start the rebuilding manually? I thought the whole point was to have this done automatically and without the need of stopping the server. Or does it perhaps rebuild automatically indeed but needs to have enough time without rebooting because otherwise the rebuilding process will start from scratch? It seems to take more than 3h for a 73gb disk! My second question is: can I mix then hard drives? So if I have a RAID of 5x73GB 10K can I use different size (146GB) or speeds (15K)? Apparently someone said it is OK in here Poweredge 2850: replace disk with larger in RAID?

    Read the article

  • Check for updates of a specific Debian package list

    - by Erwan Queffélec
    The setup I run a Debian Squeeze host that I use to build a multilanguage project (python, java, php...) and generate custom packages (debian and RPM) automatically (through jenkins) The problem The target distributions of those Debian packages are Etch, Lenny and Squeeze. But our project has some native dependencies that are available only through the DebianRelease + 1 repository (i.e Lenny + 1 == Squeeze, Squeeze + 1 == Wheezy). We for example, need the jetty packages from Squeeze in Lenny, and the cyrus-imapd-2.4 packages from Wheezy in Squeeze. Some additional info : Some package we can simply 'backport by hand' by mirroring the DebianRelease + 1 packages to our own repositories. For instance, the jetty package from Squeeze will run fine on Lenny because it doesn't need an s**tload of additional dependencies However we do need to rebuild some packages. For instance, cyrus-imapd-2.4 from Wheezy has a lot of unsatisfied dependencies on Squeeze. So we need to rebuild it in Squeeze and then upload it to our repo. The question I need to have a simple way of knowing if they are any updates on those extra packages (both "normal" and "security" updates). I could write a simple script that runs weekly, get some parameters from a file, and generate an update report. Let's say the file looks like this: jetty:squeeze cyrus-imapd-2.4:wheezy The script should run as normal user not to mess up the system apt configuration and issue the appropriate commands to generate that report. Does Debian has some built-in apt-* commands/options dedicated to that kind of problem I could use to write this script ? If not, can someone think of another clean solution to achieve what I need ?

    Read the article

  • Outlook 2007 will not send/receive using RPC over HTTP to an exchange server.. works for other users

    - by bob franklin smith harriet
    I have an incredibly frustrating user issue that I have been unable to resolve for over a week, any ideas for this would be greatly appreciated. The user is having troubles using Outlook 2007 to send or receive emails over using RPC over HTTP (Outlook Anywhere) to an exchange server. Basically what happens, the connection will be establised and the user will be prompted for the username and password, those are submitted and then outlook tries to download emails which fails and the connection to the exchange server will remain unavailable. The machine can ping and everything to the exchange server there is no connection issue there. The setup worked fine for him up untill now and also works for possibly hundreds of other users using the exact same settings, also the same settings will work from the users iphone on the same internet connection, and from my own system using outlook. The exchange server has the webmail https feature and that can be logged into and send and receive emails fine. Steps taken so far: removing the .ost file for the account and allowing office to rebuild it (fixes the issue for a short period of time, then the same symptons occur) deleted exchange profile and recreated (no change in issue) uninstalled all antivirus and firewalls (no change in issue) removed all cached passwords (keymgr.dll) (no change in issue) removed all entries from the hosts file (no change in issue) uninstalled and reinstalled office 2007 (Temporary fix of issue) Installing Symantec Endpoint Client caused a lot of email scan popups to be displayed, after a reboot this stopped and a scan it picked a few trojans that it removed. This fixed the issue temporarily as well, the issue is back again now. I am completely out of ideas now, there seems to be nothing that can be done to fix this issue outside of rebuilding the PC which is a massive pandoras box I don't want to enter with this user. --- Update ---- Malware scans from multiple products have been run on the machine and all updates were installed. The real problem with this user is his distance from us, there is no way to supply a spare laptop or rebuild the machine currently.

    Read the article

  • WSUS trying to download all updates again

    - by Tim Alexander
    The server hosting WSUS had a catastrophic failure and we have had to rebuild the system drives. Luckily the DB and content store for WSUS are on a seperate drive so were unaffected. During the rebuild process we thought it was time to update the server to 2008 R2 (from 2003 R2). Have got the server running and installed the WSUS role, detached the DB form SQL Express 2008 R2 and attached the original. Carried out the wsusutil.exe movecontent command with a -skipcopy switch pointing to the original content store. All looked good until I saw the front page stating it is trying to download files for 6,436 updates at around 344,565 MB!!!!!! Oops, I thought, something not right here. The content store I have on disk is only 75GB but I am thinking that some vital step has been missed in the restoration process. Either way is there a way to make WSUS reindex its local content store or something as I am unsure that downloading 344 gigabytes is a viable way forward! EDIT: Never rains but it pours. AM now getting a CLSID: FX {8b6499ed-0241-e032-6508-da4b1c879d7e} error could not create snap in. think a reinstall of WSUS is in order.

    Read the article

  • Missing BootMgr in Vista

    - by Selase
    Am in really deep trouble here and would use every advice available from everyone out there.. Am message just pooped on my screen and i had to restart my laptop. upon restarting the BootMgr got corrupted. Am running Windows Vista 32 bit by the way.. i got onto Google with a friend's PC and found two basic ways of fixing it. the first one that requires windows to automatically fix it using Startup repair ends up with the error message : "Startup REpair cannot repair this computer automatically" the second option that requires me to rebuild the BCD scans my system and finds the operating system on drive D:\Windows which i believe should be C:. if i hit Y(yes) for the rebuild process to take place i get the message "The required system device cannot be found" i then try the second option which requires me to recreate the BCD Store ends up with an error message that says "The store export operation has failed. The requested system device cannot be found". proceeding from there is meaningless since the system device cannot be found. I somehow believe the device cannot be found because its identifying the windows installation on D: instead of C: but how to change that i have no idea... I dot know how it happens to identify an O/S on D: when there's none there... How do i go about fixing the BootMgr? I have very important files on my system and cant afford to reinstall windows... i really need to fix this..Please help...

    Read the article

  • Resize Win2003 system+boot partitions to bigger disks & different controller?

    - by ane
    Have an old Win2003 server with 1 SCSI hard drive partitioned as follows: D: boot (includes D:\ntldr, boot.ini, etc.) C: system (includes C:\WINDOWS) Want to move the whole system to new hardware with bigger drives and different controllers. Specifically, C: to a 300GB SAS drive, and D: to a 2TB SATA drive. Tried: VMWare Converter - VMWare Server - Diskpart Result: Diskpart refuses to resize system or boot disks VMWare Converter - VMWare Server - GParted Result: Will not boot (see http://serverfault.com/questions/219868/resize-ntfs-system-partitions-with-gparted ) Attach original VMWare disk to a duplicate VMWare install - Diskpart Result: Will not boot (goes to Directory Services Restore mode) Backup Exec System Recovery Server Edition 2010 with Restore Anywhere (tried restoring both to VMWare and to the bare system, without VMWare) Result: Windows Boot error: Could not read from the selected boot disk. Check boot path. Supposedly this is a boot.ini problem, so I try bootcfg /rebuild from the recovery console. Says it can't find windows partition so it can't rebuild. Thought about Ghost but it's completely different hardware/controllers that we're restoring to, so I doubt it would boot. Reinstalling Windows from scratch is not an option due to critical custom software heavily embedded on the original machine. Has anyone been in a similar situation (with unusual boot/system partitions) before and figured out how to resize onto different disks?

    Read the article

  • How to interrupt software raid resync?

    - by Adam5
    I want to interrupt a running resync operation on a debian squeeze software raid. (This is the regular scheduled compare resync. The raid array is still clean in such a case. Do not confuse this with a rebuild after a disk failed and was replaced.) How to stop this scheduled resync operation while it is running? Another raid array is "resync pending", because they all get checked on the same day (sunday night) one after another. I want a complete stop of this sunday night resyncing. [Edit: sudo kill -9 1010 doesn't stop it, 1010 is the PID of the md2_resync process] I would also like to know how I can control the intervals between resyncs and the remainig time till the next one. [Edit2: What I did now was to make the resync go very slow, so it does not disturb anymore: sudo sysctl -w dev.raid.speed_limit_max=1000 taken from http://www.cyberciti.biz/tips/linux-raid-increase-resync-rebuild-speed.html During the night I will set it back to a high value, so the resync can terminate. This workaround is fine for most situations, nonetheless it would be interesting to know if what I asked is possible. For example it does not seem to be possible to grow an array, while it is resyncing or resyncing "pending"]

    Read the article

  • Should I use "Raid 5 + spare" or "Raid 6"?

    - by Trevor Boyd Smith
    What is "Raid 5 + Spare" (excerpt from User Manual, Sect 4.17.2, P.54): RAID5+Spare: RAID 5+Spare is a RAID 5 array in which one disk is used as spare to rebuild the system as soon as a disk fails (Fig. 79). At least four disks are required. If one physical disk fails, the data remains available because it is read from the parity blocks. Data from a failed disk is rebuilt onto the hot spare disk. When a failed disk is replaced, the replacement becomes the new hot spare. No data is lost in the case of a single disk failure, but if a second disk fails before the system can rebuild data to the hot spare, all data in the array will be lost. What is "Raid 6" (excerpt from User Manual, Sect 4.17.2, P.54): RAID6: In RAID 6, data is striped across all disks (minimum of four) and a two parity blocks for each data block (p and q in Fig. 80) is written on the same stripe. If one physical disk fails, the data from the failed disk can be rebuilt onto a replacement disk. This Raid mode can support up to two disk failures with no data loss. RAID 6 provides for faster rebuilding of data from a failed disk. Both "Raid 5 + spare" and "Raid 6" are SO similar ... I can't tell the difference. When would "Raid 5 + Spare" be optimal? And when would "Raid 6" be optimal"? The manual dumbs down the different raid with 5 star ratings. "Raid 5 + Spare" only gets 4 stars but "Raid 6" gets 5 stars. If I were to blindly trust the manual I would conclude that "Raid 6" is always better. Is "Raid 6" always better?

    Read the article

  • kde dropping keyboard

    - by shabbychef
    I am having problems with KDE 'dropping' my keyboard. It happens periodically when using my gentoo box directly, but has become much worse when accessing via NX (from a Mac laptop). Some possibly irrelevant clues: it appears to happen more often when the system is under higher CPU load the mouse continues to work, but no windows will accept any kind of keyboard focus. kwin will not accept tabbing between windows. when working on the machine directly, I can ctrl-alt-F1 to get to a shell (obviously this does nothing over NX). so I think it is KDE and not xorg. am running kwin-4.3.5-r1, and KDE-4.3.5 generally. this problem definitely appeared after upgrading to kde-4.x, but I do not remember if it appeared in kde-4.2. sometimes the keyboard will reappear, but sometimes I have to kill my kde session. playing with accessibility options or window-focus-stealing options in system-settings under kde will often make the keyboard responsive again, only to drop it perhaps minutes later. I had read online this might be an evdev problem under X (again, I think this is KDE, not X, but will try anything). as a result, I have fiddled with my xorg.conf endlessly. I even deleted it entirely and let nvidia-xconfig have a stab at it, with no luck I am tearing my hair out over this. I have done emerge -e xorg-server and am right now doing emerge -e kwin, to rebuild all packages that might be relevant. no luck with the xorg-server rebuild. any help appreciated. thanks,

    Read the article

  • Rebuilding LVM after RAID recovery

    - by Xiong Chiamiov
    I have 4 disks RAID-5ed to create md0, and another 4 disks RAID-5ed to create md1. These are then combined via LVM to create one partition. There was a power outage while I was gone, and when I got back, it looked like one of the disks in md1 was out of sync - mdadm kept claiming that it only could find 3 of the 4 drives. The only thing I could do to get anything to happen was to use mdadm --create on those four disks, then let it rebuild the array. This seemed like a bad idea to me, but none of the stuff I had was critical (although it'd take a while to get it all back), and a thread somewhere claimed that this would fix things. If this trashed all of my data, then I suppose you can stop reading and just tell me that. After waiting four hours for the array to rebuild, md1 looked fine (I guess), but the lvm was complaining about not being able to find a device with the correct UUID, presumably because md1 changed UUIDs. I used the pvcreate and vgcfgrestore commands as documented here. Attempting to run an lvchange -a y on it, however, gives me a resume ioctl failed message. Is there any hope for me to recover my data, or have I completely mucked it up?

    Read the article

  • Missing Boot Manager in Vista

    - by Selase
    I am in really deep trouble here and would need advice. A message just pop up on my screen and I had to restart my laptop. Upon restarting the Boot Manager got corrupted. I am running Windows Vista 32 bit by the way. I got onto Google with a friend's PC and found two basic ways of fixing it. The first one that requires Windows to automatically fix it using Startup repair ends up with the error message: Startup REpair cannot repair this computer automatically The second option that requires me to rebuild the BCD scans my system and finds the operating system on drive D:\Windows which I believe should be C:. If I hit Y(yes) for the rebuild process to take place I get the message The required system device cannot be found I then try the second option which requires me to recreate the BCD Store. It ends up with an error message that says: The store export operation has failed. The requested system device cannot be found Proceeding from there is meaningless since the system device cannot be found. I somehow believe the device cannot be found because it's identifying the Windows installation on D: instead of C: but how to change that I have no idea. I don't know how it happens to identify an operating system on D: when there's none there. How do I go about fixing the Boot Manager? I have very important files on my system and can't afford to reinstall Windows. I really need to fix this.

    Read the article

  • Cannot get at data in my NAS

    - by Ben
    I've got a bit of an issue that I'm hoping you can help me with. I have an Iomega ix4 as my NAS. This runs Linux and each drive in the box has 2 partitions: one for the OS and RAID info, and the second for the actual data. I had it configured as RAID5. Recently one of the drives failed. At this point all of the data was available, it was just reporting a failed drive. I had a drive of the same capacity (although not the exact same spec) which I swapped in place of the failed drive. It recognised it, and started to rebuild the data protection. So far so good ... or so I thought. The next day, after data protection had finished reconstructing, the NAS was telling me that 4 new drives had been added, and wanted confirmation to overwrite the data. Obviously I declined to do this. I swapped the failed drive back in again, in the hope that it would return to its previous state of the data being accessible, but one failed disk. However it didn't - it still tells me that the NAS has 4 new drives in it. I am hopeful that the actual data is untouched, so what I need to do is get it to rebuild the RAID without touching the data on the disks. I have ssh access, and have run stuff like mdadm --examine to see what I can find. The mdadm.conf file has no entry in the "definitions of existing MD arrays" section. I have not run any actual rebuilding commands as yet, because this is entering an area which I am out of my depth in. Please can someone advise the best way of getting my data? Thanks.

    Read the article

  • Connection drop problem with Hibernate-mysql-c3p0

    - by user344788
    hi all, This is an issue which I have seen all across the web. I will bring it up again as till now I don't have a fix for the same. I am using hibernate 3. mysql 5 and latest c3p0 jar. I am getting a broken pipe exception. Following is my hibernate.cfg file. com.mysql.jdbc.Driver org.hibernate.dialect.MySQLDialect <property name="hibernate.show_sql">true</property> <property name="hibernate.use_sql_comments">true</property> <property name="hibernate.current_session_context_class">thread</property> <property name="connection.autoReconnect">true</property> <property name="connection.autoReconnectForPools">true</property> <property name="connection.is-connection-validation-required">true</property> <!--<property name="c3p0.min_size">5</property> <property name="c3p0.max_size">20</property> <property name="c3p0.timeout">1800</property> <property name="c3p0.max_statements">50</property> --><property name="hibernate.connection.provider_class">org.hibernate.connection.C3P0ConnectionProvider </property> <property name="hibernate.c3p0.acquireRetryAttempts">30</property> <property name="hibernate.c3p0.acquireIncrement">5</property> <property name="hibernate.c3p0.automaticTestTable">C3P0TestTable</property> <property name="hibernate.c3p0.idleConnectionTestPeriod">36000</property> <property name="hibernate.c3p0.initialPoolSize">20</property> <property name="hibernate.c3p0.maxPoolSize">100</property> <property name="hibernate.c3p0.maxIdleTime">1200</property> <property name="hibernate.c3p0.maxStatements">50</property> <property name="hibernate.c3p0.minPoolSize">10</property>--> My connection pooling is occurring fine. During the day it is fine , but once i keep it idle over the night ,next day I find it giving me broken connection error. public class HibernateUtil { private static Logger log = Logger.getLogger(HibernateUtil.class); //private static Log log = LogFactory.getLog(HibernateUtil.class); private static Configuration configuration; private static SessionFactory sessionFactory; static { // Create the initial SessionFactory from the default configuration files try { log.debug("Initializing Hibernate"); // Read hibernate.properties, if present configuration = new Configuration(); // Use annotations: configuration = new AnnotationConfiguration(); // Read hibernate.cfg.xml (has to be present) configuration.configure(); // Build and store (either in JNDI or static variable) rebuildSessionFactory(configuration); log.debug("Hibernate initialized, call HibernateUtil.getSessionFactory()"); } catch (Throwable ex) { // We have to catch Throwable, otherwise we will miss // NoClassDefFoundError and other subclasses of Error log.error("Building SessionFactory failed.", ex); throw new ExceptionInInitializerError(ex); } } /** * Returns the Hibernate configuration that was used to build the SessionFactory. * * @return Configuration */ public static Configuration getConfiguration() { return configuration; } /** * Returns the global SessionFactory either from a static variable or a JNDI lookup. * * @return SessionFactory */ public static SessionFactory getSessionFactory() { String sfName = configuration.getProperty(Environment.SESSION_FACTORY_NAME); System.out.println("Current s name is "+sfName); if ( sfName != null) { System.out.println("Looking up SessionFactory in JNDI"); log.debug("Looking up SessionFactory in JNDI"); try { System.out.println("Returning new sssion factory"); return (SessionFactory) new InitialContext().lookup(sfName); } catch (NamingException ex) { throw new RuntimeException(ex); } } else if (sessionFactory == null) { System.out.println("calling rebuild session factory now"); rebuildSessionFactory(); } return sessionFactory; } /** * Closes the current SessionFactory and releases all resources. * <p> * The only other method that can be called on HibernateUtil * after this one is rebuildSessionFactory(Configuration). */ public static void shutdown() { log.debug("Shutting down Hibernate"); // Close caches and connection pools getSessionFactory().close(); // Clear static variables sessionFactory = null; } /** * Rebuild the SessionFactory with the static Configuration. * <p> * Note that this method should only be used with static SessionFactory * management, not with JNDI or any other external registry. This method also closes * the old static variable SessionFactory before, if it is still open. */ public static void rebuildSessionFactory() { log.debug("Using current Configuration to rebuild SessionFactory"); rebuildSessionFactory(configuration); } /** * Rebuild the SessionFactory with the given Hibernate Configuration. * <p> * HibernateUtil does not configure() the given Configuration object, * it directly calls buildSessionFactory(). This method also closes * the old static variable SessionFactory before, if it is still open. * * @param cfg */ public static void rebuildSessionFactory(Configuration cfg) { log.debug("Rebuilding the SessionFactory from given Configuration"); if (sessionFactory != null && !sessionFactory.isClosed()) sessionFactory.close(); if (cfg.getProperty(Environment.SESSION_FACTORY_NAME) != null) { log.debug("Managing SessionFactory in JNDI"); cfg.buildSessionFactory(); } else { log.debug("Holding SessionFactory in static variable"); sessionFactory = cfg.buildSessionFactory(); } configuration = cfg; } } Above is my code for the session factory. And I have only select operations . And below is the method which is used most often to execute my select queries. One tricky thing which I am not understanding is in my findById method i am using this line of code getSession().beginTransaction(); without which it gives me an error saying that this cannot happpen without a transaction. But nowhere I am closing this transaction. And thers no method to close a transaction apart from commit or rollback (as far as i know) which are not applicable for select statements. public T findById(ID id, boolean lock) throws HibernateException, DAOException { log.debug("findNyId invoked with ID ="+id+"and lock ="+lock); T entity; getSession().beginTransaction(); if (lock) entity = (T) getSession().load(getPersistentClass(), id, LockMode.UPGRADE); else entity = (T) getSession().load(getPersistentClass(), id); return entity; } Can anyone please suggest what can I do ? I have tried out almost every solution available via googling, on stackoverlow or on hibernate forums with no avail. (And increasing wait_timeout on mysql is not a valid option in my case).

    Read the article

  • Ajax Control Toolkit November 2011 Release

    - by Stephen Walther
    I’m happy to announce the November 2011 Release of the Ajax Control Toolkit. This release introduces a new Balloon Popup control and several enhancements to the existing Tabs control including support for on-demand loading of tab content, support for vertical tabs, and support for keyboard tab navigation. We also fixed the top-voted bugs associated with the Tabs control reported at CodePlex.com. You can download the new release by visiting the CodePlex website: http://AjaxControlToolkit.CodePlex.com Alternatively, the fast and easy way to get the latest release of the Ajax Control Toolkit is to use NuGet. Open your Library Package Manager console in Visual Studio 2010 and type: After you install the Ajax Control Toolkit through NuGet, please do a Rebuild of your project (the menu option Build, Rebuild). After you do a Rebuild, the ajaxToolkit prefix will appear in Intellisense: Using the Balloon Popup Control Why a new Balloon Popup control? The Balloon Popup control is the second most requested new feature for the Ajax Control Toolkit according to CodePlex votes: The Balloon Popup displays a message in a balloon when you shift focus to a control, click a control, or hover over a control. You can use the Balloon Popup, for example, to display instructions for TextBoxes which appear in a form: Here’s the code used to create the Balloon Popup: <ajaxToolkit:ToolkitScriptManager ID="tsm1" runat="server" /> <asp:TextBox ID="txtFirstName" Runat="server" /> <asp:Panel ID="pnlFirstNameHelp" runat="server"> Please enter your first name </asp:Panel> <ajaxToolkit:BalloonPopupExtender TargetControlID="txtFirstName" BalloonPopupControlID="pnlFirstNameHelp" BalloonSize="Small" UseShadow="true" runat="server" /> You also can use the Balloon Popup to explain hard to understand words in a text document: Here’s how you display the Balloon Popup when you hover over the link: The point of the conversation was <asp:HyperLink ID="lnkObfuscate" Text="obfuscated" CssClass="hardWord" runat="server" /> by his incessant coughing. <ajaxToolkit:ToolkitScriptManager ID="tsm1" runat="server" /> <asp:Panel id="pnlObfuscate" Runat="server"> To bewilder or render something obscure </asp:Panel> <ajaxToolkit:BalloonPopupExtender TargetControlID="lnkObfuscate" BalloonPopupControlID="pnlObfuscate" BalloonStyle="Cloud" UseShadow="true" DisplayOnMouseOver="true" Runat="server" />   There are four important properties which you need to know about when using the Balloon Popup control: BalloonSize – The three balloon sizes are Small, Medium, and Large. BalloonStyle -- The two built-in styles are Rectangle and Cloud. UseShadow – When true, a drop shadow appears behind the popup. Position – Can have the values Auto, BottomLeft, BottomRight, TopLeft, TopRight. When set to Auto, which is the default, the Balloon Popup will appear where it has the most screen real estate. The following screenshots illustrates how these settings affect the appearance of the Balloon Popup: Customizing the Balloon Popup You can customize the appearance of the Balloon Popup by creating your own Cascading Style Sheet and Sprite. The Ajax Control Toolkit sample site includes a sample of a custom Oval Balloon Popup style: This custom style was created by using a custom Cascading Style Sheet and image. You point the Balloon Popup at a custom Cascading Style Sheet and Cascading Style Sheet class by using the CustomCssUrl and CustomClassName properties like this: <asp:TextBox ID="txtCustom" autocomplete="off" runat="server" /> <br /> <asp:Panel ID="Panel3" runat="server"> This is a custom BalloonPopupExtender style created with a custom Cascading Style Sheet. </asp:Panel> <ajaxToolkit:BalloonPopupExtender ID="bpe1" TargetControlID="txtCustom" BalloonPopupControlID="Panel3" BalloonStyle="Custom" CustomCssUrl="CustomStyle/BalloonPopupOvalStyle.css" CustomClassName="oval" UseShadow="true" runat="server" />   Learn More about the Balloon Popup To learn more about the Balloon Popup control, visit the sample page for the Balloon Popup at the Ajax Control Toolkit sample site: http://www.asp.net/ajaxLibrary/AjaxControlToolkitSampleSite/BalloonPopup/BalloonPopupExtender.aspx Improvements to the Tabs Control In this release, we introduced several important new features for the existing Tabs control. We also fixed all of the top-voted bugs for the Tabs control. On-Demand Loading of Tab Content Here is the scenario. Imagine that you are using the Tabs control in a Web Forms page. The Tabs control displays two tabs: Customers and Products. When you click the Customers tab then you want to see a list of customers and when you click on the Products tab then you want to see a list of products. In this scenario, you don’t want the list of customers and products to be retrieved from the database when the page is initially opened. The user might never click on the Products tab and all of the work to load the list of products from the database would be wasted. In this scenario, you want the content of a tab panel to be loaded on demand. The products should only be loaded from the database and rendered to the browser when you click the Products tab and not before. The Tabs control in the November 2011 Release of the Ajax Control Toolkit includes a new property named OnDemand. When OnDemand is set to the value True, a tab panel won’t be loaded until you click its associated tab. Here is the code for the aspx page: <ajaxToolkit:ToolkitScriptManager ID="tsm1" runat="server" /> <ajaxToolkit:TabContainer ID="tabs" OnDemand="false" runat="server"> <ajaxToolkit:TabPanel HeaderText="Customers" runat="server"> <ContentTemplate> <h2>Customers</h2> <asp:GridView ID="grdCustomers" DataSourceID="srcCustomers" runat="server" /> <asp:SqlDataSource ID="srcCustomers" SelectCommand="SELECT * FROM Customers" ConnectionString="<%$ ConnectionStrings:StoreDB %>" runat="server" /> </ContentTemplate> </ajaxToolkit:TabPanel> <ajaxToolkit:TabPanel HeaderText="Products" runat="server"> <ContentTemplate> <h2>Products</h2> <asp:GridView ID="grdProducts" DataSourceID="srcProducts" runat="server" /> <asp:SqlDataSource ID="srcProducts" SelectCommand="SELECT * FROM Products" ConnectionString="<%$ ConnectionStrings:StoreDB %>" runat="server" /> </ContentTemplate> </ajaxToolkit:TabPanel> </ajaxToolkit:TabContainer> Notice that the TabContainer includes an OnDemand=”True” property. The Tabs control contains two Tab Panels. The first tab panel uses a DataGrid and SqlDataSource to display a list of customers and the second tab panel uses a DataGrid and SqlDataSource to display a list of products. And here is the code-behind for the page: using System; using System.Diagnostics; using System.Web.UI.WebControls; namespace ACTSamples { public partial class TabsOnDemand : System.Web.UI.Page { protected override void OnInit(EventArgs e) { srcProducts.Selecting += new SqlDataSourceSelectingEventHandler(srcProducts_Selecting); } void srcProducts_Selecting(object sender, SqlDataSourceSelectingEventArgs e) { Debugger.Break(); } } } The code-behind file includes an event handler for the Products SqlDataSource Selecting event. The handler breaks into the debugger by calling the Debugger.Break() method. That way, we can know when the Products SqlDataSource actually retrieves the list of products. When the OnDemand property has the value False then the Selecting event handler is called immediately when the page is first loaded. The contents of all of the tabs are loaded (and the contents of the unselected tabs are hidden) when the page is first loaded. When the OnDemand property has the value True then the Selecting event handler is not called when the page is first loaded. The event handler is not called until you click on the Products tab. If you never click on the Products tab then the list of products is never retrieved from the database. If you want even more control over when the contents of a tab panel gets loaded then you can use the TabPanel OnDemandMode property. This property accepts the following three values: None – Never load the contents of the tab panel again after the page is first loaded. Once – Wait until the tab is selected to load the contents of the tab panel Always – Load the contents of the tab panel each and every time you select the tab. There is a live demonstration of the OnDemandMode property here in the sample page for the Tabs control: http://www.asp.net/ajaxLibrary/AjaxControlToolkitSampleSite/Tabs/Tabs.aspx Displaying Vertical Tabs With the November 2011 Release, the Tabs control now supports vertical tabs. To create vertical tabs, just set the TabContainer UserVerticalStripPlacement property to the value True like this: <ajaxToolkit:TabContainer ID="tabs" OnDemand="false" UseVerticalStripPlacement="true" runat="server"> <ajaxToolkit:TabPanel ID="TabPanel1" HeaderText="First Tab" runat="server"> <ContentTemplate> <p> Lorem ipsum dolor sit amet, consectetuer adipiscing elit. Maecenas porttitor congue massa. Fusce posuere, magna sed pulvinar ultricies, purus lectus malesuada libero, sit amet commodo magna eros quis urna. </p> </ContentTemplate> </ajaxToolkit:TabPanel> <ajaxToolkit:TabPanel ID="TabPanel2" HeaderText="Second Tab" runat="server"> <ContentTemplate> <p> Lorem ipsum dolor sit amet, consectetuer adipiscing elit. Maecenas porttitor congue massa. Fusce posuere, magna sed pulvinar ultricies, purus lectus malesuada libero, sit amet commodo magna eros quis urna. </p> </ContentTemplate> </ajaxToolkit:TabPanel> </ajaxToolkit:TabContainer> In addition, you can use the TabStripPlacement property to control whether the tab strip appears at the left or right or top or bottom of the tab panels: Tab Keyboard Navigation Another highly requested feature for the Tabs control is support for keyboard navigation. The Tabs control now supports the arrow keys and the Home and End keys. In order for the arrow keys to work, you must first move focus to the tab control on the page by either clicking on a tab with your mouse or repeatedly hitting the Tab key. You can try out the new keyboard navigation support by trying any of the demos included in the Tabs sample page: http://www.asp.net/ajaxLibrary/AjaxControlToolkitSampleSite/Tabs/Tabs.aspx Summary I hope that you take advantage of the new Balloon Popup control and the new features which we introduced for the Tabs control. We added a lot of new features to the Tabs control in this release including support for on-demand tabs, support for vertical tabs, and support for tab keyboard navigation. I want to thank the developers on the Superexpert team for all of the hard work which they put into this release.

    Read the article

  • LSI 9285-8e and Supermicro SC837E26-RJBOD1 duplicate enclosure ID and slot numbers

    - by Andy Shinn
    I am working with 2 x Supermicro SC837E26-RJBOD1 chassis connected to a single LSI 9285-8e card in a Supermicro 1U host. There are 28 drives in each chassis for a total of 56 drives in 28 RAID1 mirrors. The problem I am running in to is that there are duplicate slots for the 2 chassis (the slots list twice and only go from 0 to 27). All the drives also show the same enclosure ID (ID 36). However, MegaCLI -encinfo lists the 2 enclosures correctly (ID 36 and ID 65). My question is, why would this happen? Is there an option I am missing to use 2 enclosures effectively? This is blocking me rebuilding a drive that failed in slot 11 since I can only specify enclosure and slot as parameters to replace a drive. When I do this, it picks the wrong slot 11 (device ID 46 instead of device ID 19). Adapter #1 is the LSI 9285-8e, adapter #0 (which I removed due to space limitations) is the onboard LSI. Adapter information: Adapter #1 ============================================================================== Versions ================ Product Name : LSI MegaRAID SAS 9285-8e Serial No : SV12704804 FW Package Build: 23.1.1-0004 Mfg. Data ================ Mfg. Date : 06/30/11 Rework Date : 00/00/00 Revision No : 00A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.25.00_4.11.05.00_0x05040000 WebBIOS Version : 6.1-20-e_20-Rel Preboot CLI Version: 05.01-04:#%00001 FW Version : 3.140.15-1320 NVDATA Version : 2.1106.03-0051 Boot Block Version : 2.04.00.00-0001 BOOT Version : 06.253.57.219 Pending Images in Flash ================ None PCI Info ================ Vendor Id : 1000 Device Id : 005b SubVendorId : 1000 SubDeviceId : 9285 Host Interface : PCIE ChipRevision : B0 Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5003048000ee8e7f 1 5003048000ee8a7f 2 0000000000000000 3 0000000000000000 4 0000000000000000 5 0000000000000000 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 500605b0038f9210 BBU : Present Alarm : Present NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Memory Size : 1024MB TPM : Absent On board Expander: Absent Upgrade Key : Absent Temperature sensor for ROC : Present Temperature sensor for controller : Absent ROC temperature : 70 degree Celcius Settings ================ Current Time : 18:24:36 3/13, 2012 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% BGI Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache Flush Interval : 4s Max Drives to Spinup at One Time : 2 Delay Among Spinup Groups : 12s Physical Drive Coercion Mode : Disabled Cluster Mode : Disabled Alarm : Enabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare on Insertion : Disabled Expose Enclosure Devices : Enabled Maintain PD Fail History : Enabled Host Request Reordering : Enabled Auto Detect BackPlane Enabled : SGPIO/i2c SEP Load Balance Mode : Auto Use FDE Only : No Security Key Assigned : No Security Key Failed : No Security Key Not Backedup : No Default LD PowerSave Policy : Controller Defined Maximum number of direct attached drives to spin up in 1 min : 10 Any Offline VD Cache Preserved : No Allow Boot with Preserved Cache : No Disable Online Controller Reset : No PFK in NVRAM : No Use disk activity for locate : No Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span Supported Drives : SAS, SATA Allowed Mixing: Mix in Enclosure Allowed Mix of SAS/SATA of HDD type in VD Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 60 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 42 Max LD per array : 16 Min Strip Size : 8 KB Max Strip Size : 1.0 MB Max Configurable CacheCade Size: 0 GB Current Size of CacheCade : 0 GB Current Size of FW Cache : 887 MB Device Present ================ Virtual Drives : 28 Degraded : 0 Offline : 0 Physical Devices : 59 Disks : 56 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : No Spanning : Yes Dedicated Hot Spare : Yes Revertible Hot Spares : Yes Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy on Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Support Security : No Snapshot Enabled : No Support the OCE without adding drives : Yes Support PFK : Yes Support PI : No Support Boot Time PFK Change : Yes Disable Online PFK Change : No PFK TrailTime Remaining : 0 days 0 hours Support Shield State : Yes Block SSD Write Disk Cache Change: Yes Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Allow Ctrl Encryption: No Enable LDBBM : No Support Breakmirror : No Power Savings : Yes Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Support Temperature : Yes Disable Copyback : No Enable JBOD : No Enable Copyback on SMART : No Enable Copyback to SSD on SMART Error : Yes Enable SSD Patrol Read : No PR Correct Unconfigured Areas : Yes Enable Spin Down of UnConfigured Drives : Yes Disable Spin Down of hot spares : No Spin Down time : 30 T10 Power State : Yes Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Background Rate : 30 Strip Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : Adaptive Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : Yes Coercion Mode : None ZCR Config : Unknown Dirty LED Shows Drive Activity : No BIOS Continue on Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix in Enclosure : Yes Allow HDD SAS/SATA Mix in VD : Yes Allow SSD SAS/SATA Mix in VD : No Allow HDD/SSD Mix in VD : No Allow SATA in Cluster : No Max Chained Enclosures : 16 Disable Ctrl-R : Yes Enable Web BIOS : Yes Direct PD Mapping : No BIOS Enumerate VDs : Yes Restore Hot Spare on Insertion : No Expose Enclosure Devices : Yes Maintain PD Fail History : Yes Disable Puncturing : No Zero Based Enclosure Enumeration : No PreBoot CLI Enabled : Yes LED Show Drive Activity : Yes Cluster Disable : Yes SAS Disable : No Auto Detect BackPlane Enable : SGPIO/i2c SEP Use FDE Only : No Enable Led Header : No Delay during POST : 0 EnableCrashDump : No Disable Online Controller Reset : No EnableLDBBM : No Un-Certified Hard Disk Drives : Allow Treat Single span R1E as R10 : No Max LD per array : 16 Power Saving option : Don't Auto spin down Configured Drives Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. Default spin down time in minutes: 30 Enable JBOD : No TTY Log In Flash : No Auto Enhanced Import : No BreakMirror RAID Support : No Disable Join Mirror : No Enable Shield State : Yes Time taken to detect CME : 60s Exit Code: 0x00 Enclosure information: # /opt/MegaRAID/MegaCli/MegaCli64 -encinfo -a1 Number of enclosures on adapter 1 -- 3 Enclosure 0: Device ID : 36 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port B Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 65 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11820 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 48 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 1: Device ID : 65 Number of Slots : 28 Number of Power Supplies : 2 Number of Fans : 3 Number of Temperature Sensors : 1 Number of Alarms : 1 Number of SIM Modules : 0 Number of Physical Drives : 28 Status : Normal Position : 1 Connector Name : Port A Enclosure type : SES VendorId is LSI CORP and Product Id is SAS2X36 VendorID and Product ID didnt match FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : 36 Inquiry data : Vendor Identification : LSI CORP Product Identification : SAS2X36 Product Revision Level : 0718 Vendor Specific : x36-55.7.24.1 Number of Voltage Sensors :2 Voltage Sensor :0 Voltage Sensor Status :OK Voltage Value :5020 milli volts Voltage Sensor :1 Voltage Sensor Status :OK Voltage Value :11760 milli volts Number of Power Supplies : 2 Power Supply : 0 Power Supply Status : OK Power Supply : 1 Power Supply Status : OK Number of Fans : 3 Fan : 0 Fan Speed :Low Speed Fan Status : OK Fan : 1 Fan Speed :Low Speed Fan Status : OK Fan : 2 Fan Speed :Low Speed Fan Status : OK Number of Temperature Sensors : 1 Temp Sensor : 0 Temperature : 47 Temperature Sensor Status : OK Number of Chassis : 1 Chassis : 0 Chassis Status : OK Enclosure 2: Device ID : 252 Number of Slots : 8 Number of Power Supplies : 0 Number of Fans : 0 Number of Temperature Sensors : 0 Number of Alarms : 0 Number of SIM Modules : 1 Number of Physical Drives : 0 Status : Normal Position : 1 Connector Name : Unavailable Enclosure type : SGPIO Failed in first Inquiry commnad FRU Part Number : N/A Enclosure Serial Number : N/A ESM Serial Number : N/A Enclosure Zoning Mode : N/A Partner Device Id : Unavailable Inquiry data : Vendor Identification : LSI Product Identification : SGPIO Product Revision Level : N/A Vendor Specific : Exit Code: 0x00 Now, notice that each slot 11 device shows an enclosure ID of 36, I think this is where the discrepancy happens. One should be 36. But the other should be on enclosure 65. Drives in slot 11: Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 5, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 48 WWN: Sequence Number: 11 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : YES Device Firmware Level: A5C0 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8a53 Connected Port Number: 1(path0) Inquiry Data: MJ1311YNG6YYXAHitachi HDS5C3030ALA630 MEAOA5C0 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Enclosure Device ID: 36 Slot Number: 11 Drive's postion: DiskGroup: 19, Span: 0, Arm: 1 Enclosure position: 0 Device Id: 19 WWN: Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SATA Raw Size: 2.728 TB [0x15d50a3b0 Sectors] Non Coerced Size: 2.728 TB [0x15d40a3b0 Sectors] Coerced Size: 2.728 TB [0x15d400000 Sectors] Firmware state: Online, Spun Up Is Commissioned Spare : NO Device Firmware Level: A580 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5003048000ee8e53 Connected Port Number: 0(path0) Inquiry Data: MJ1313YNG1VA5CHitachi HDS5C3030ALA630 MEAOA580 FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive Temperature :30C (86.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Drive's write cache : Disabled Drive's NCQ setting : Enabled Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No Update 06/28/12: I finally have some new information about (what we think) the root cause of this problem so I thought I would share. After getting in contact with a very knowledgeable Supermicro tech, they provided us with a tool called Xflash (doesn't appear to be readily available on their FTP). When we gathered some information using this utility, my colleague found something very strange: root@mogile2 test]# ./xflash.dat -i get avail Initializing Interface. Expander: SAS2X36 (SAS2x36) 1) SAS2X36 (SAS2x36) (50030480:00EE917F) (0.0.0.0) 2) SAS2X36 (SAS2x36) (50030480:00E9D67F) (0.0.0.0) 3) SAS2X36 (SAS2x36) (50030480:0112D97F) (0.0.0.0) This lists the connected enclosures. You see the 3 connected (we have since added a 3rd and a 4th which is not yet showing up) with their respective SAS address / WWN (50030480:00EE917F). Now we can use this address to get information on the individual enclosures: [root@mogile2 test]# ./xflash.dat -i 5003048000EE917F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00EE917F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 5003048000E9D67F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:00E9D67F Enclosure Logical Id: 50030480:0000007F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 [root@mogile2 test]# ./xflash.dat -i 500304800112D97F get exp Initializing Interface. Expander: SAS2X36 (SAS2x36) Reading the expander information.......... Expander: SAS2X36 (SAS2x36) B3 SAS Address: 50030480:0112D97F Enclosure Logical Id: 50030480:0112D97F IP Address: 0.0.0.0 Component Identifier: 0x0223 Component Revision: 0x05 Did you catch it? The first 2 enclosures logical ID is partially masked out where the 3rd one (which has a correct unique enclosure ID) is not. We pointed this out to Supermicro and were able to confirm that this address is supposed to be set during manufacturing and there was a problem with a certain batch of these enclosures where the logical ID was not set. We believe that the RAID controller is determining the ID based on the logical ID and since our first 2 enclosures have the same logical ID, they get the same enclosure ID. We also confirmed that 0000007F is the default which comes from LSI as an ID. The next pointer that helps confirm this could be a manufacturing problem with a run of JBODs is the fact that all 6 of the enclosures that have this problem begin with 00E. I believe that between 00E8 and 00EE Supermicro forgot to program the logical IDs correctly and neglected to recall or fix the problem post production. Fortunately for us, there is a tool to manage the WWN and logical ID of the devices from Supermicro: ftp://ftp.supermicro.com/utility/ExpanderXtools_Lite/. Our next step is to schedule a shutdown of these JBODs (after data migration) and reprogram the logical ID and see if it solves the problem. Update 06/28/12 #2: I just discovered this FAQ at Supermicro while Google searching for "lsi 0000007f": http://www.supermicro.com/support/faqs/faq.cfm?faq=11805. I still don't understand why, in the last several times we contacted Supermicro, they would have never directed us to this article :\

    Read the article

  • SQL SERVER – Updating Data in A Columnstore Index

    - by pinaldave
    So far I have written two articles on Columnstore Indexes, and both of them got very interesting readership. In fact, just recently I got a query on my previous article on Columnstore Index. Read the following two articles to get familiar with the Columnstore Index. They will give you a reference to the question which was asked by a certain reader: SQL SERVER – Fundamentals of Columnstore Index SQL SERVER – How to Ignore Columnstore Index Usage in Query Here is the reader’s question: ” When I tried to update my table after creating the Columnstore index, it gives me an error. What should I do?” When the Columnstore index is created on the table, the table becomes Read-Only table and it does not let any insert/update/delete on the table. The basic understanding is that Columnstore Index will be created on the table that is very huge and holds lots of data. If a table is small enough, there is no need to create a Columnstore index. The regular index should just help it. The reason why Columnstore index was needed is because the table was so big that retrieving the data was taking a really, really long time. Now, updating such a huge table is always a challenge by itself. If the Columnstore Index is created on the table, and the table needs to be updated, you need to know that there are various ways to update it. The easiest way is to disable the Index and enable it. Consider the following code: USE AdventureWorks GO -- Create New Table CREATE TABLE [dbo].[MySalesOrderDetail]( [SalesOrderID] [int] NOT NULL, [SalesOrderDetailID] [int] NOT NULL, [CarrierTrackingNumber] [nvarchar](25) NULL, [OrderQty] [smallint] NOT NULL, [ProductID] [int] NOT NULL, [SpecialOfferID] [int] NOT NULL, [UnitPrice] [money] NOT NULL, [UnitPriceDiscount] [money] NOT NULL, [LineTotal] [numeric](38, 6) NOT NULL, [rowguid] [uniqueidentifier] NOT NULL, [ModifiedDate] [datetime] NOT NULL ) ON [PRIMARY] GO -- Create clustered index CREATE CLUSTERED INDEX [CL_MySalesOrderDetail] ON [dbo].[MySalesOrderDetail] ( [SalesOrderDetailID]) GO -- Create Sample Data Table -- WARNING: This Query may run upto 2-10 minutes based on your systems resources INSERT INTO [dbo].[MySalesOrderDetail] SELECT S1.* FROM Sales.SalesOrderDetail S1 GO 100 -- Create ColumnStore Index CREATE NONCLUSTERED COLUMNSTORE INDEX [IX_MySalesOrderDetail_ColumnStore] ON [MySalesOrderDetail] (UnitPrice, OrderQty, ProductID) GO -- Attempt to Update the table UPDATE [dbo].[MySalesOrderDetail] SET OrderQty = OrderQty +1 WHERE [SalesOrderID] = 43659 GO /* It will throw following error Msg 35330, Level 15, State 1, Line 2 UPDATE statement failed because data cannot be updated in a table with a columnstore index. Consider disabling the columnstore index before issuing the UPDATE statement, then rebuilding the columnstore index after UPDATE is complete. */ A similar error also shows up for Insert/Delete function. Here is the workaround. Disable the Columnstore Index and performance update, enable the Columnstore Index: -- Disable the Columnstore Index ALTER INDEX [IX_MySalesOrderDetail_ColumnStore] ON [dbo].[MySalesOrderDetail] DISABLE GO -- Attempt to Update the table UPDATE [dbo].[MySalesOrderDetail] SET OrderQty = OrderQty +1 WHERE [SalesOrderID] = 43659 GO -- Rebuild the Columnstore Index ALTER INDEX [IX_MySalesOrderDetail_ColumnStore] ON [dbo].[MySalesOrderDetail] REBUILD GO This time it will not throw an error while the update of the table goes successfully. Let us do a cleanup of our tables using this code: -- Cleanup DROP INDEX [IX_MySalesOrderDetail_ColumnStore] ON [dbo].[MySalesOrderDetail] GO TRUNCATE TABLE dbo.MySalesOrderDetail GO DROP TABLE dbo.MySalesOrderDetail GO In the next post we will see how we can use Partition to update the Columnstore Index. Reference: Pinal Dave (http://blog.SQLAuthority.com) Filed under: Pinal Dave, PostADay, SQL, SQL Authority, SQL Index, SQL Query, SQL Scripts, SQL Server, SQL Tips and Tricks, T SQL, Technology

    Read the article

  • Default Parameters vs Method Overloading

    - by João Angelo
    With default parameters introduced in C# 4.0 one might be tempted to abandon the old approach of providing method overloads to simulate default parameters. However, you must take in consideration that both techniques are not interchangeable since they show different behaviors in certain scenarios. For me the most relevant difference is that default parameters are a compile time feature while method overloading is a runtime feature. To illustrate these concepts let’s take a look at a complete, although a bit long, example. What you need to retain from the example is that static method Foo uses method overloading while static method Bar uses C# 4.0 default parameters. static void CreateCallerAssembly(string name) { // Caller class - Invokes Example.Foo() and Example.Bar() string callerCode = String.Concat( "using System;", "public class Caller", "{", " public void Print()", " {", " Console.WriteLine(Example.Foo());", " Console.WriteLine(Example.Bar());", " }", "}"); var parameters = new CompilerParameters(new[] { "system.dll", "Common.dll" }, name); new CSharpCodeProvider().CompileAssemblyFromSource(parameters, callerCode); } static void Main() { // Example class - Foo uses overloading while Bar uses C# 4.0 default parameters string exampleCode = String.Concat( "using System;", "public class Example", "{{", " public static string Foo() {{ return Foo(\"{0}\"); }}", " public static string Foo(string key) {{ return \"FOO-\" + key; }}", " public static string Bar(string key = \"{0}\") {{ return \"BAR-\" + key; }}", "}}"); var compiler = new CSharpCodeProvider(); var parameters = new CompilerParameters(new[] { "system.dll" }, "Common.dll"); // Build Common.dll with default value of "V1" compiler.CompileAssemblyFromSource(parameters, String.Format(exampleCode, "V1")); // Caller1 built against Common.dll that uses a default of "V1" CreateCallerAssembly("Caller1.dll"); // Rebuild Common.dll with default value of "V2" compiler.CompileAssemblyFromSource(parameters, String.Format(exampleCode, "V2")); // Caller2 built against Common.dll that uses a default of "V2" CreateCallerAssembly("Caller2.dll"); dynamic caller1 = Assembly.LoadFrom("Caller1.dll").CreateInstance("Caller"); dynamic caller2 = Assembly.LoadFrom("Caller2.dll").CreateInstance("Caller"); Console.WriteLine("Caller1.dll:"); caller1.Print(); Console.WriteLine("Caller2.dll:"); caller2.Print(); } And if you run this code you will get the following output: // Caller1.dll: // FOO-V2 // BAR-V1 // Caller2.dll: // FOO-V2 // BAR-V2 You see that even though Caller1.dll runs against the current Common.dll assembly where method Bar defines a default value of “V2″ the output show us the default value defined at the time Caller1.dll compiled against the first version of Common.dll. This happens because the compiler will copy the current default value to each method call, much in the same way a constant value (const keyword) is copied to a calling assembly and changes to it’s value will only be reflected if you rebuild the calling assembly again. The use of default parameters is also discouraged by Microsoft in public API’s as stated in (CA1026: Default parameters should not be used) code analysis rule.

    Read the article

  • NHibernate.Search - async mode

    - by Atul
    Hi, I am using NHibernate Lucene search in my project. Lucene.Net.dll - v - 2.3.1.3 NHibernate.dll - v - 2.1.0.4000 At this point I am trying to use async option for indexing and used following options config.SetProperty(NHibernate.Search.Environment.WorkerExecution, "async"); config.SetProperty(NHibernate.Search.Environment.WorkerThreadPoolSize, "1"); config.SetProperty(NHibernate.Search.Environment.WorkerWorkQueueSize, "5000"); Questions 1) My initial index was not build with this option, when used these settings first time, I had error saying NHibernate.Search.dll not found. When I deleted existing index and then started working, it went fine. Do we need to rebuild indexes whenever we change config settings like above ? 2) How size of index should be interpreted; i.e. initially my index was about 400MB (build over the last few months), which I deleted. Later when I reindexed, the size of index went down to 5MB ! Search appear to be alright after limited testing, but such a change appeared bit scary. Should we delete/rebuild indexes once in a while & is it normal to change this drastically ? 3) Is my above setting is OK ? When I had WorkerThreadPoolSize=5, I once got Dr Watson kind of error. Please advise on best practices of using async configuration for search. Regards, Atul

    Read the article

  • program "is not up to date" execution error in wedit lcc-win32

    - by Rowhawn
    I'm attempting to compile a simple hello world program in c with lcc-win32/wedit, and i'm a little unfamiliar with windows c programming. #include int main(void){ printf("hellow\n"); return 0; } When I compile the program the console output is Wedit output window build: Tue Jun 15 09:13:17 2010 c:\lcc\lib\lcccrt0.obj .text: undefined reference to '_RtlUnwind@16' c:\lcc\lib\lcccrt0.obj .text: undefined reference to '_signal' c:\lcc\lib\lcccrt0.obj .text: undefined reference to '_raise' c:\lcc\lib\lcccrt0.obj .text: undefined reference to '_exit' asctoq.obj .text: undefined reference to '_strnicmp' defaulttrap.obj .text: undefined reference to 'imp_iob' defaulttrap.obj .text: undefined reference to '_fwrite' defaulttrap.obj .text: undefined reference to '_itoa' defaulttrap.obj .text: undefined reference to '_strcat' defaulttrap.obj .text: undefined reference to '_MessageBoxA@16' defaulttrap.obj .text: undefined reference to '_abort' powlasm.obj .text: undefined reference to '_pow' qfloat.obj .text: undefined reference to '_memset' qfloat.obj .text: undefined reference to '_strchr' qfloat.obj .text: undefined reference to '_memmove' strlcpy.obj .text: undefined reference to '_memcpy' xprintf.obj .text: undefined reference to '_localeconv' xprintf.obj .text: undefined reference to '_strtol' xprintf.obj .text: undefined reference to '_wcslen' xprintf.obj .text: undefined reference to '_wctomb' xprintf.obj .text: undefined reference to '_fputc' search Compilation + link time:0.1 sec, Return code: 60 when I attempt to execute the program within wedit i get a dialog box that says "hello.exe is not up-to-date. Rebuild?" If I click yes, nothing happens. If I click no, a dos window pops up saying "C:\lcc\projects\lcc2\hello.exe" Return code -1 Execution time 0.001 seconds Press any key to continue... This continues to happen no matter how many times i compile/rebuild. Any ideas?

    Read the article

  • Different location of assemblies stoped the type casting.

    - by smwikipedia
    I am writing a custom Control class in C# for my main project. There're 2 projects, one for my Control and one for my main project. These 2 projects are in the same solution. I add a reference from my main project to my Control project. I notice that the first time after I drag my Control from the Tool Panel onto my main winform, an assembly folder was generated at the C:\Users\XXX\AppData\Local\Microsoft\VisualStudio\9.0\ProjectAssemblies, and the folder name is something like "jlebh-py01". The first build is always OK, but after I rebuild my Control class or whole solution, a new assembly folder will be generated at C:\Users\XXX\AppData\Local\Microsoft\VisualStudio\9.0\ProjectAssemblies, and then problem arises, my Control fails to behave well because Visual Studio says that the two types "originates from different location". The error message is as below: [A]MyControl.TypeXXX cannot be cast to [B]MyControl.TypeXXX. Type A orginates from assemblyXXX at location 'C:\Users\XXX\AppData\Local\Microsoft\VisualStudio\9.0\ProjectAssemblies\jlebh-py01\MyControl.dll' Type B originats from assemblyXXX at location 'C:\Users\XXX\AppData\Local\Microsoft\VisualStudio\9.0\ProjectAssemblies\ue4i-z3j01\MyControl.dll' If I reference the Control DLL directly instead of through project reference, or never rebuild the Control project after use my Control in the main project, things seem to be OK. Does anyone knows why? Is it the proper way to develop a control and a main project within the same solution? Many thanks...

    Read the article

  • NAnt exec relative path

    - by stacker
    How can I assign to trunk.dir property a relative path to the trunk location? This is my nant.build file: <?xml version="1.0" encoding="utf-8"?> <project name="ProjectName" default="build" xmlns="http://nant.sf.net/release/0.85/nant.xsd"> <!-- Directories --> <property name="trunk.dir" value="C:\Projects\ProjectName" /><!-- I want relative path over here! --> <property name="source.dir" value="${trunk.dir}src\" /> <!-- Working Files --> <property name="msbuild.exe" value="C:\WINDOWS\Microsoft.NET\Framework\v4.0.30319\msbuild.exe" /> <property name="solution.sln" value="${source.dir}ProjectName.sln" /> <!-- Called Externally --> <target name="compile"> <!-- Rebuild foces msbuild to clean and build --> <exec program="${msbuild.exe}" commandline="${solution.sln} /t:Rebuild /v:q" /> </target> </project>

    Read the article

  • How do I stop the m2eclipse plugin interfering with command line mvn builds?

    - by locka
    I use the m2eclipse plugin in Eclipse so that I can import a Maven project. The plugin reads the pom.xml and sorts out the dependencies in the projects in an Eclipse friendly way so I'm not looking at a sea of broken references and errors. I use Eclipse for code development however I usually build the projects from the command line, e.g. "mvn clean install". Unfortunately when I do this, m2eclipse detects disk activity and attempts to rebuild the workspace. This interferes with the command line build and sometimes results in a race condition. For example the command line might be in its clean phase but fails because it tries to delete a file or directory which is locked during the workspace rebuild. Aside from that workspace rebuilding is incredibly slow, and between failed builds and wasted CPU my build process is 2-3x longer than it should be. It isn't an option to not use Eclipse (e.g. to use Netbeans), or to disable m2eclipse. It is a useful plugin except for this behaviour. So my question is, how do I stop m2eclipse from rebuilding the workspace all the time? Can I invoke a manual refresh and otherwise disable this behaviour?

    Read the article

  • missing rake tasks ??

    - by richard moss
    hi I have ran gem install rails and am running 2.3.4 but i am missing some rake tasks like 'db' and 'gems' if i run rake -T i get the following tasks. How can i get all the others ? rake apache2 # Build Apache 2 module rake clean # Remove compiled files rake clobber # Remove all generated files rake default # Build everything rake doc # Generate all documentation rake doxygen # Generate Doxygen C++ API documentation if ... rake doxygen:clobber # Remove generated Doxygen C++ API documenta... rake doxygen:force # Force generation of Doxygen C++ API docume... rake fakeroot # Create a fakeroot, useful for building nat... rake nginx # Build Nginx helper server rake package # Build all the packages rake package:clean # Remove package products rake package:debian # Create a Debian package rake package:force # Force a rebuild of the package files rake package:gem # Build the gem file passenger-2.2.4.gem rake rdoc # Build the rdoc HTML Files rake rdoc:clobber # Remove rdoc products rake rdoc:force # Force a rebuild of the RDOC files rake sloccount # Run 'sloccount' to see how much code Passe... rake test # Run all unit tests and integration tests rake test:cxx # Run unit tests for the Apache 2 and Nginx ... rake test:integration # Run all integration tests rake test:integration:apache2 # Run Apache 2 integration tests rake test:integration:nginx # Run Nginx integration tests rake test:oxt # Run unit tests for the OXT library rake test:rcov # Run coverage tests for the Ruby libraries rake test:restart # Run the 'restart' integration test infinit... rake test:ruby If anyone knows why this has happened, how i can fix it or anything else that could help, please let me know thanks alot rick

    Read the article

  • What VC++ compiler/linker does when building a C++ project with Managed Extension

    - by ???
    The initial problem is that I tried to rebuild a C++ project with debug symbols and copied it to test machine, The output of the project is external COM server(.exe file). When calling the COM interface function, there's a RPC call failre: COMException(0x800706BE): The remote procedure call failed. According to the COM HRESULT design, if the FACILITY code is 7, it's actually a WIN32 error, and the win32 error code is 0x6BE, which is the above mentioned "remote procedure call failed". All I do is replace the COM server .exe file, the origin file works well. When I checked into the project, I found it's a C++ project with Managed Extension. When I checking the DLL with reflector, it shows there's 2 additional .NET assembly reference. Then I checked the project setting and found nothing about the extra 2 assembly reference. I turned on the show includes option of compiler and verbose library of linker, and try to analyze whether the assembly is indirectly referenced via .h file. I've collect all the .h file and grep all the files with '#using' '#import' and the assembly file itself. There really is a '#using ' in one of the .h file but not-relevant to the referenced assembly. And about the linked .lib library files, only one of the .lib file is a side-product of another managed-extension-enabled C++ project, all others are produced by a pure, traditional C++ project. For the managed-extension-enabled C++ project, I checked the output DLL assembly, it did NOT reference to the 2 assembly. I even try to capture the access of the additional assembly file via sysinternal's filemon and procmon, but the rebuild process does NOT access these file. I'm very confused about the compile and linking process model of a VC++/CLI project, where the additional assembly reference slipped into the final assembly? Thanks in advance for any of your help.

    Read the article

  • NAnt and relative path execution

    - by stacker
    How can I assign to trunk.dir property a relative path to the trunk location? This is my nant.build file: <?xml version="1.0" encoding="utf-8"?> <project name="ProjectName" default="build" xmlns="http://nant.sf.net/release/0.85/nant.xsd"> <!-- Directories --> <property name="trunk.dir" value="C:\Projects\ProjectName" /><!-- I want relative path over here! --> <property name="source.dir" value="${trunk.dir}src\" /> <!-- Working Files --> <property name="msbuild.exe" value="C:\WINDOWS\Microsoft.NET\Framework\v4.0.30319\msbuild.exe" /> <property name="solution.sln" value="${source.dir}ProjectName.sln" /> <!-- Called Externally --> <target name="compile"> <!-- Rebuild foces msbuild to clean and build --> <exec program="${msbuild.exe}" commandline="${solution.sln} /t:Rebuild /v:q" /> </target> </project>

    Read the article

< Previous Page | 4 5 6 7 8 9 10 11 12 13 14 15  | Next Page >